Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.5.

* Denotes standards that are incorporated by reference in 19 NYCRR part 1227.

Margin markings have not been made in this chapter. The date of the reference standard denotes new standards from the 2007 code.

 

ASCE American Society of Civil Engineers
1801 Alexander Bell Drive
Reston, VA 20191-4400
 
Standard
reference
number
Title Referenced
in code
section number
*7—05 Minimum Design Loads for Buildings and Other Structures with Supplement No. 1 302.2.3.1, 302.2.3.2,
305.3, 506.1.1.2
*31—03 Seismic Evaluation of Existing Buildings 506.1.1.1, Table 506.1.1.2, 506.1.1.3
*41—06 Seismic Rehabilitation of Existing Buildings 506.1.1.1, 506.1.1.2, Table 506.1.1.2, 506.1.1.3

 

ASHRAE American Society of Heating, Refrigerating and Air Conditioning Engineers
1791 Tullie Circle, NE
Atlanta, GA 30329
 
Standard
reference
number
Title Referenced
in code
section number
*62.1—07 Ventilation for Acceptable Indoor Air Quality 709.2
*62.2—07 Ventilation for Acceptable Indoor Air Quality in Low-Rise Residential Buildings 709.2

 


ASME American Society of Mechanical Engineers
3 Park Avenue
New York, NY 10016
 
Standard
reference
number
Title Referenced
in code
section number
*A17.1—07 Safety Code for Elevators and Escalators 308.8.2, 605.1.2, 802.1.2
*A17.3—05 Safety Code for Existing Elevators and Escalators 802.1.2
*A18.1—05 Safety Standard for Platform Lifts and Stairway Chair Lifts 308.8.3, 605.1.3

 

ICC International Code Council, Inc.
5203 Leesburg Pike, Suite 600
Falls Church, VA 22041
 
Standard
reference
number
Title Referenced
in code
section number
BCNYS—10 Building Code of New York State 101.5, 101.4.2, 101.5, 202, 302.1, 302.1.1, 302.2, 302.2.2, 302.2.3.2, 302.2.5, 302.4, 305.1, 305.3, 307.1, 308.1, 308.4, 308.6, 308.8.1, 308.8.4, 308.8.5, 308.8.7, 308.8.11, 401.3, 501.4, 502.2, 506.1.1.1, 506.1.1.2, Table 506.1.1.2, 506.1.1.3, 506.1.2, 506.2.2.1, 506.2.2.3, 506.2.3, 506.2.4, 506.2.5, 601.2, 601.3, 602.1, 602.2, 602.3, 603.2, 605.1, 605.1.1, 605.1.4, 605.1.8, 606.2.1, 606.2.2, 608.1, 701.3, 702.1, 703.2.1, 703.2.3, 703.3.2, 703.4, 703.5.2, 704.2, 704.2.2, 704.2.3, 704.2.4, 704.3, 705.2, 705.3.1, 705.4.3, 705.5, 705.6, 705.7.1, 705.8.1, 705.9.2, 705.10.2, 705.11, 706.2, 706.3, 707.1, 707.2, 707.3, 707.4, 707.4.1, 707.4.3, 802.3.1, 802.3.2, 802.3.3, 804.1.2, 804.2, 804.2.1, 804.2.2, 805.2, 805.3, 806.2, 807.2, 807.3, 807.5, 807.5.2, 807.6, 807.7, 902.1, 902.2, 902.3.1, 902.3.2, 907.1, 907.2, 907.3.1, 911.1, 912.1.1.1, 912.1.1.2, 912.2.1, 912.2.2, 912.3, 912.4.1, 912.4.2, 912.4.3, 912.5.1, 912.5.3, 912.6.1, 912.6.3, 912.7.1, 912.7.2, 912.7.3, 912.8, 1001.1, 1002.1, 1002.2, 1002.3, 1003.1, 1003.2, 1003.3, 1003.3.1, 1003.3.2, 1003.4, 1003.5, 1004.1, 1101.4, 1102.3, 1102.5, 1103.12.1, 1103.13, 1104.1.4, 1105.2, 1105.9, 1201.2, 1202.1, 1202.2, 1202.2.1, 1202.3, 1202.4, 1202.5, 1202.6, 1301.2.2, 1301.2.3, 1301.2.4, 1301.2.5, 1301.3.3, 1301.4.1, 1301.6.1, 1301.6.1.1, 1301.6.2, 1301.6.2.1, 1301.6.3.1, 1301.6.3.2, 1301.6.4.1, 1301.6.5, 1301.6.5.1, 1301.6.6, 1301.6.7.1, 1301.6.8, 1301.6.9, 1301.6.9.1, 1301.6.10.1, 1301.6.11, 1301.6.11.1, 1301.6.12.1, 1301.6.13, 1301.6.14, 1301.6.14.1, 1301.6.15.1, Table 1301.6.15, 1301.6.16.1, 1301.6.17,1301.6.17.1, 1301.6.18, 1301.6.18.1, 1301.6.19, Table l301.6.19, 1401.6.1, 1401.6.4.1, 1401.6.7, 1406.3
*ICC/ANSI A117.1—03 Accessible and Usable Buildings and Facilities 308.6, 308.8.2, 308.8.3, 605.1, 605.1.2, 605.1.3
*ICC 300—02 Standards on Bleachers, Folding and Telescopic Seating and Grandstand 301.1
ECCCNYS—10 Energy Conservation Construction Code of New York State 101.3, 202, 302.5, 602.3, 607.2, 711.2, 808.2, 911.2
FCNYS—10 Fire Code of New York State 101.5.1, 102.3, 102.8, 102.8.2, 103.4, 503.3, 703.2.1, 703.2.3, 704.4.1.1, 704.4.1.2, 704.4.1.3, 704.4.1.4, 704.4.1.5, 704.4.1.6, 704.4.1.7, 704.4.3, 705.7.2, 802.3.3, 802.3.4, 902.3.3, 902.3.4, 902.3.5, 904.2, 912.5.1, 1006.1, 1103.13, 1103.14, 1201.2, 1301.2.6, 1301.3.2, 1301.6.8.1, 1301.6.14, 1301.6.14.1, 1404.1, 1404.2
FGCNYS—10 Fuel Gas Code of New York State 302.7, 305.7, 602.3.1
MCNYS—10 Mechanical Code of New York State 302.8, 305.8, 602.3.1, 709.1, 802.1.1, 802.2.1, 909.1, 1301.6.7.1, 1301.6.8, 1301.6.8.1
PCNYS—10 Plumbing Code of New York State 302.9, 305.9, 509.1, 602.3, 710.1, 910.1, 910.2, 910.3, 910.5, 1401.5
PMCNYS—10 Property Maintenance Code of New York State 102.8, 1201.2, 1301.3.2
RCNYS—10 Residential Code of New York State 101.2, 502.2, 506.1.2, 602.3, 606.2.1, 708.3, 711.1

 

NFPA National Fire Protection Agency
1 Batterymarch Park
Quincy, MA 02269-9101
 
Standard
reference
number
Title Referenced
in code
section number
13 Installation of Sprinkler Systems Table 705.3.1.1(1)
*13R—07 Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height 704.2.5
*70—08 National Electrical Code 302.6, 305.5, 507.1.1, 507.1.2, 507.1.3, 507.1.4, 507.1.5, 602.3, Table 705.3.1.1(1), 708.1, 708.3.4, 708.3.7, 908.1, 908.2, 908.3, 908.4
*72—07 National Fire Alarm Code 704.2.5, 704.4
*99—05 Health Care Facilities 507.1.4
*101—06 Life Safety Code 705.2
*101A—10 Guide on Alternative Approaches to Life Safety 1101.2.1
*720—09 Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment  
*914—07 Code for Fire Protection for Historic Buildings 1101.2.1