This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

*Denotes standards that are incorporated by reference into 19 NYCRR Part 1240.

AAMA

American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg IL 60173-4268

AAMA/WDMA/CSA 101/I.S.2/A C440—17:

North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights

R402.4.3

ACCA

Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington VA 22206

*Manual J—11:

Residential Load Calculation Eighth Edition

R403.7

*Manual S—14:

Residential Equipment Selection

R403.7

APSP

The Association of Pool & Spa Professionals
2111 Eisenhower Avenue, Suite 500
Alexandria VA 22314

ANSI/APSP/ICC 14—2014:

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2011:

American National Standard for Residential Swimming Pool and Spa Energy Efficiency—includes Addenda A Approved January 9, 2013

R403.12

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329

*ASHRAE—2017:

2017 ASHRAE Fundamentals Handbook

R402.1.5

*ASHRAE—2001:

2001 ASHRAE Fundamentals Handbook

Table R405.5.2(1)

ASHRAE 193—2010(RA 2014):

Method of Test for Determining the Airtightness of HVAC Equipment

R403.3.2.1

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959

C1363—11:

Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus

R303.1.4.1

E283—04(2012):

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen

R402.4.4

*E779—10:

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

R402.4.1.2

*E1827—11:

Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door

R402.4.1.2

BOMA

Building Owners and Managers Association (BOMA) International
1101 15th Street. NW Suite 800
Washington DC 20005

*ANSI/BOMA Z65.1—1996:

Standard Method for Measuring Floor Area in Office Buildings

R402.4.1.2, R402.4.1.3

CSA

CSA Group
8501 East Pleasant Valley Road
Cleveland OH 44131-5516

AAMA/WDMA/CSA 101/I.S.2/A440—17:

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3

CSA B55.1—2015:

Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units

R403.5.4

CSA B55.2—2015:

Drain Water Heat Recovery Units

R403.5.4

DASMA

Door & Access Systems Manufacturers Association
1300 Sumner Avenue
Cleveland OH 44115-2851

105—2016:

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors

R303.1.3

HVI

Home Ventilating Institute
1000 North Rand Road, Suite 214
Wauconda IL 60084

916—09:

Airflow Test Procedure

Table R403.6.1

ICC

International Code Council, Inc.
500 New Jersey Avenue NW
6th Floor
Washington DC 20001

ANSI/APSP/ICC 14—2014:

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2011:

American National Standard for Residential Swimming Pool and Spa Energy Efficiency—includes Addenda A Approved January 9, 2013

R403.12

*ANSI/RESNET/ICC 301—2014:

Standard for the Calculation and Labeling of the Energy Performance of Low-rise Residential Buildings using an Energy Rating Index First Published March 7, 2014—Republished January 2016, including Addenda D, E, G and K.

R406.3

*ANSI/RESNET/ICC 380—2016:

Standard for Testing Airtightness for Building Enclosures, Airtightness of Heating and Cooling Air Distribution Systems and Airflow of Mechanical Ventilation Systems—Republished January 2016, including Addendum A.

R402.4.1.2, R403.3.3

*BCNYS—20:

Building Code of New York State

R201.3, R303.1.1, R303.2, R402.1.1, R501.4

*EBCNYS—20:

Existing Building Code of New York State

R501.4

*ECCCNYS—20:

Energy Conservation Construction Code of New York State

R102.1.1, R403.8

*ECCCNYS—2010:

Energy Conservation Construction Code of New York State (2010 edition)

R406.2

ICC 400—17:

Standard on the Design and Construction of Log Structures

R402.1

*IECC—15:

2015 International Energy Conservation Code, second printing: May 2015

Table R406.4

*FCNYS—20:

Fire Code of New York State

R201.3, R501.4

*FGCNYS—20:

Fuel Gas Code of New York State

R201.3, R501.4

*MCNYS—20:

Mechanical Code of New York State

R201.3, R403.3.2, R403.3.6, R403.6, R501.4

*PCNYS—20:

Plumbing Code of New York State

R201.3, R501.4

*PMCNYS—20:

Property Maintenance Code of New York State

R501.4

IEEE

Institute of Electrical and Electronic Engineers, Inc.
3 Park Avenue, 17th Floor
New York NY 10016-5997

515.1—2012:

IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications

R403.5.1.2

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471

*70—17:

National Electrical Code

R501.4

NFRC

National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt MD 20770

100—2017:

Procedure for Determining Fenestration Products U-factors

R303.1.3

200—2017:

Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence

R303.1.3

400—2017:

Procedure for Determining Fenestration Product Air Leakage

R402.4.3

RESNET

Residential Energy Services Network, Inc.
P.O. Box 4561
Oceanside CA 92052-4561

*ANSI/RESNET/ICC 301—2014:

Standard for the Calculation and Labeling of the Energy Performance of Low-rise Residential Buildings using an Energy Rating Index First Published March 7, 2014—Republished January 2016

R406.3, R406.6.1, R406.6.5

*ANSI/RESNET/ICC 380—2016:

Standard for Testing Airtightness for Building Enclosures, Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems—Republished January 2016

R402.4.1.2

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062

127—11:

Standard for Factory Built Fireplaces—with Revisions through May 2015

R402.4.2

515—11:

Electrical Resistance Heat Tracing for Commercial and Industrial Applications Including Revisions through July 2015

R403.5.1.2

US-FTC

United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington DC 20580

CFR Title 16 (2015):

R-value Rule

R303.1.4

WDMA

Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington DC 20036-3309

AAMA/WDMA/CSA 101/I.S.2/A440—17:

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3