This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 107.
* Denotes standards that are incorporated by reference into 19 NYCRR part 1240.
Margin markings have not been made in this chapter. The date of the referenced standards denotes new standards from the 2007 code.
* Denotes standards that are incorporated by reference into 19 NYCRR part 1240.
Margin markings have not been made in this chapter. The date of the referenced standards denotes new standards from the 2007 code.
AAMA | American Architectural Manufacturers Association 1827 Walden Office Square, Suite 550 Schaumburg, IL 60173-4268 | |
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A440—08 | Specifications for Windows, Doors and Unit Skylights | 402.4.4, 502.4.1 |
ACCA | Air Conditioning Contractors of America 2800 Shirlington Road, Suite 300 Arlington, VA 22206 | |
Standard reference number | Title | Referenced in code section number |
Manual J—87 | Residential Load Calculation Seventh Edition | 403.6, 405.6.1 |
AFPA | American Forest & Paper Association 1111 19th St, NW, Suite 800 Washington, DC 20036 | |
Standard reference number | Title | Referenced in code section number |
*NDS—05 | National Design Specification (NDS) for Wood Construction with 2005 Supplement. | Table 402.1.5.1, Table 402.1.5.2 |
AHRI | Air Conditioning, Heating and Refrigeration Institute 4301 North Fairfax Drive Suite 200 Arlington, VA 22203 | |||
Standard reference number | Title | Referenced in code section number | ||
210/240—03 | Unitary Air-Conditioning and Air-Source Heat Pump Equipment | Table 503.2.3(1), Table 503.2.3(2) | ||
310/380—93 | Standard for Packaged Terminal Air-conditioners and Heat Pumps | Table 503.2.3(3) | ||
340/360—2000 | Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment | Table 503.2.3(1), Table 503.2.3(2) | ||
365—02 | Commercial and Industrial Unitary Air-conditioning Condensing Units | Table 503.2.3(6) | ||
*440—05 | Performance Rating of Room Fan-Coils | 503.2.8 | ||
550/590—98 | Water Chilling Packages Using the Vapor Compression Cycle with Addenda | Table 503.2.3(7) | ||
560—00 | Absorption Water Chilling and Water Heating Packages | Table 503.2.3(7) | ||
*840—98 | Unit Ventilators | 503.2.8 | ||
13256—1 (2005) | Water-source Heat Pumps—Testing and Rating for Performance— Part 1: Water-to-air and Brine-to-air Heat Pumps (ANSI/AHRI/ASHRAE/ISO 13256-1) | Table 503.2.3(2) | ||
1160—2004 | Performance Rating of Heat Pump Pool Heaters | Table 504.2 |
AISI | American Iron and Steel Institute 1140 Connecticut Avenue, Suite 705 Washington, DC 20036 | |
Standard reference number | Title | Referenced in code section number |
S230—07 | Standard for Cold-Formed Steel Framing-Prescriptive Method for One- and Two-Family Dwellings | Table 402.1.5.1, Table 402.1.5.2, Table 502.2.8.1, Table 502.2.8.2 |
AMCA | Air Movement and Control Association International 30 West University Drive Arlington Heights, IL 60004-1806 | |
Standard reference number | Title | Referenced in code section number |
500D—98 | Laboratory Methods for Testing Dampers for Rating | 502.4.4 |
ANSI | American National Standards Institute 25 West 43rd Street, Fourth Floor New York, NY 10036 | |
Standard reference number | Title | Referenced in code section number |
Z21.10.3—01 | Gas Water Heaters, Volume III - Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous—with Addenda Z21.10.3a-2003 and Z21.10.3b 2004 | Table 504.2 |
Z21.13—04 | Gas-fired Low Pressure Steam and Hot Water Boilers | Table 503.2.3(5) |
Z21.47—03 | Gas-fired Central Furnaces | Table 503.2.3(4) |
Z21.50—07 | Vented Gas Fireplace (CSA ANSI Z21.50 / CSA 2.22) | 303.1.5 |
Z21.60—03 | Decorative Gas Burning Appliances for Installation in Solid-Fuel Burning Fireplaces with addenda Z21.60a—2003 (CSA ANSI Z21.50 / CSA 2.26) | 303.1.5 |
Z21.50/CSA 2.22—07 | Vented Gas Fireplaces (ANSI Z21.50/CSA 2.22) | 303.1.5 |
Z21.60/CSA 2.26—03 | Decorative Gas Burning Appliances for Installation in Solid Fuel Burning Fireplaces with Addendum Z21.60a—2003 (ANSI Z21.60/CSA 2.26) | 303.1.5 |
*Z65—96 | Method for Measuring Floor Area in Office Buildings | 402.4.2.1, 403.2.2 |
Z83.8—02 | Gas Unit Heaters and Gas-fired Duct Furnaces—with Addendum Z83.8a-2003 | Table 503.2.3(4) |
ASHRAE | American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1791 Tullie Circle, NE Atlanta, GA 30329-2305 | |
Standard reference number | Title | Referenced in code section number |
*90.1—2007 | Energy Standard for Buildings Except Low-rise Residential Buildings (ANSI/ASHRAE/IESNA 90.1-2007) | 101.3.1, 101.4.7, 101.5.1, 501.1, 501.2, 502.1.1, Table 502.2(2) |
*119—88 (RA 2004) | Air Leakage Performance for Detached Single-family Residential Buildings | Table 405.5.2(1) |
140—2007 | Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs | 506.6.1 |
183—2007 | Peak Cooling and Heating Load Calculations in Buildings Except Low-Rise Residential Buildings | 503.2.1 |
*13256—1 (2005) | Water-source Heat Pumps—Testing and Rating for Performance—Part 1: Water-to-air and Brine-to-air Heat Pumps (ANSI/ARI/ASHRAE/ISO 13256-1) | Table 503.2.3(2) |
*ASHRAE-152—2004 | Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems | 403.2.2 |
*ASHRAE—2005 | ASHRAE Handbook of Fundamentals—2005 | 402.1.4, Table 405.5.2(1) |
*ASHRAE—2004 | ASHRAE HVAC Systems and Equipment Handbook—2004 | 503.2.1 |
ASME | American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990 | |
Standard reference number | Title | Referenced in code section number |
PTC 4.1 - 1964 | Steam Generating Units | Table 503.2.3(5) |
ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 | |
Standard reference number | Title | Referenced in code section number |
C 90—03 | Specification for Load-bearing Concrete Masonry Units | Table 502.2(1) |
E 84—04 | Standard Test Method for Surface Buring Characteristics of Building Materials | 402.4.1(12)(c) |
*E 96—00 | Standard Test Methods for Water Vapor Transmission of Materials (Vapor Retarder) | 202 |
E 283—04 | Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen | 202, 402.4.3, 502.4.2, 502.4.7 |
*E 779—99 | Standard Test Method for Determining Air Leakage Rate by Fan Pressurization | 402.4.2.1, 502.4.3.1 |
*E 1554—03 | Standard Test Methods for Determining Air Leakage of Air Distribution Systems by Fan Pressurization | 403.2.2 |
E 1677—95 | Standard Specification for an Air Retarder (AR) Material or System for Systems Low-Rise Framed Building Walls | Table 402.1.5.1, Table 402.1.5.2, Table 502.2.8.1, Table 502.2.8.2, 502.4.3.1 |
E 2178—03 | Standard Test Method for Air Permeance of Building Materials | .202, 502.4.3.1 |
E 2357—05 | Standard Test Method for Determining Air Leakage of Air Barrier Assemblies | 502.4.3.1 |
F1667-03 | Standard Specification for Driven Fasteners: Nails, Spikes, and Staples | 402.1.5.1, 402.1.5.2, Table 502.2.8.1, Table 502.2.8.2, 502.4.3.1 |
CSA | Canadian Standards Association 5060 Spectrum Way, Suite 100 Mississauga, Ontario, L4W 5N6 Canada | |
Standard reference number | Title | Referenced in code section number |
*AAMA/WDMA/CSA 101/I.S.2/A440—08 | Specifications for Windows, Doors and Unit Skylights | 402.4.4, 502.4.1 |
DOE | U.S. Department of Energy c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 | ||||
Standard reference number | Title | Referenced in code section number | |||
10 CFR Part 430, Subpart B, Appendix E (2009) | Uniform Test Method for Measuring the Energy Consumption of Water Heaters | Table 503.2.3(4), Table 504.2 | |||
10 CFR Part 430, Subpart B, Appendix N (2009) | Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers | Table 503.2.3(4), Table 503.2.3(5) | |||
*10 CFR Part 430, Subpart B, Test Procedures (2009) | Energy Conservation Program for Consumer Products: Test Procedures for Furnaces/Boilers, Vented Home Heating Equipment and Pool Heaters | 202 | |||
10 CFR Part 431, Subpart E (2010) | Test Procedures and Efficiency Standards for Commercial Packaged Boilers | Table 503.2.3(5) | |||
DOE/EIA-0376 (Current Edition) | State Energy Prices and Expenditure Report | 405.3, 506.3 |
ICC | International Code Council, Inc. 500 New Jersey Avenue, NW 6th Floor Washington, D.C. 20001 | |
Standard reference number | Title | Referenced in code section number |
BCNYS—10 | Building Code of New York State | 201.3, 303.1.4, 303.2, T402.1.1, 502.2.8, 502.2.8.1, 502.2.8.2, Table 502.2.8.2 |
FCNYS—10 | Fire Code of New York State | 201.3 |
FGNYS—10 | Fuel Gas Code of New York State | 201.3 |
MCNYS—10 | Mechanical Code of New York State | 201.3, 503.2.5, 503.2.5.1, 503.2.6, 503.2.7, 503.2.7.1, 503.2.7.1.1, 503.2.7.1.2, 503.2.9.1, 503.3.1, 503.4.5 |
PCNYS—10 | Plumbing Code of New York State | 102.2, 201.3 |
RCNYS—10 | Residential Code of New York State | 201.3, 503.2.5, 503.2.5.1, 503.2.6, 503.2.7, |
402.1.5.2, 402.2.1.1, 402.4.1(12), 403.2.2, T405.5.2(1) | ||
NYCCC—08 | New York City Constructon Codes (including title 28 of the Administrative Code of the City of New York—08) | 101.1.2, 101.2.1, 103.2.3, 104.2, 104.8.1, 201.3, 303.1.5, 303.2, 403.2.2, 503.2.5, 503.2.5.1, 503.2.6, 503.2.7, 503.2.7.1, 503.2.7.1.1, 503.2.7.1.2, 503.2.9.1, 503.3.1, 503.4.5 |
IESNA | Illuminating Engineering Society of North America 120 Wall Street, 17th Floor New York, NY 10005-4001 | |
Standard reference number | Title | Referenced in code section number |
*90.1—2007 | Energy Standard for Buildings Except Low-rise Residential Buildings (ANSI/ASHRAE/IESNA 90.1—2007) | 101.3.1, 101.4.3, 101.5.1, 501.1, 501.2, Table 502.2(2) |
NFRC | National Fenestration Rating Council, Inc. 8484 Georgia Avenue, Suite 320 Silver Spring, MD 20910 | |
Standard reference number | Title | Referenced in code section number |
100—01 | Procedure for Determining Fenestration Product U-Factors Second Edition. | 303.1.3 |
200—01 | Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence Second Edition | 303.1.3 |
400—01 | Procedure for Determining Fenestration Product Air Leakage Second Edition | 402.4.4, 502.4.1 |
SMACNA | Sheet Metal and Air Conditioning Contractors National Association, Inc. 4201 Lafayette Center Drive Chantilly, VA 20151-1209 | |
Standard reference number | Title | Referenced in code section number |
*SMACNA 1143—85 | HVAC Air Duct Leakage Test Manual | 503.2.7.1.3 |
UL | Underwriters Laboratories 333 Pfingsten Road Northbrook, IL 60062-2096 | |
Standard reference number | Title | Referenced in code section number |
*727—06 | Oil-Fired Central Furnaces—with Revisions through January 2001 | Table 503.2.3(4) |
*731—08 | Oil-Fired Unit Heaters | Table 503.2.3(4) |
US FTC | United States Federal Trade Commission 600 Pennsylvania Avenue, NW Washington, D.C. 20580 | |
Standard reference number | Title | Referenced in code section number |
16 CFR 460 | Labeling and Advertising of Home Insulation | 303.1.4 |
WDMA | Window and Door Manufacturers Association 1400 East Touhy Avenue, Suite 470 Des Plaines, IL 60018 | |
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A440—08 | Specifications for Windows, Doors and Unit Skylights | 402.4.4, 502.4.1 |