This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

*Denotes standards that are incorporated by reference into 19 NYCRR Part 1221.

Margin markings have not beem made in this chapter. The date of the referenced standards denotes new standards from 2007.

 

AA Aluminum Association
900 - 19th Street N.W., Suite 300
Washington, DC 20006
Standard
reference
number
Title Referenced
in code
section number
*ADM 1-00 Aluminum Design Manual: Part 1-A Aluminum Structures, Allowable Stress Design; and Part 1-B- Aluminum Structures, Load and Resistance Factor Design of Buildings and Similar Type Structures 1604.3.5, 2002.1
*ASM 35-00 Specifications for Aluminum Sheet Metal Work in Building Construction (Fourth Edition) 2002.1

 

AAMA American Architectural Manufacturers Association
1827 Waldon Office Square, Suite 550
Schaumburg, IL 60173
Standard
reference
number
Title Referenced
in code
section number
1402-86 Standard Specifications for Aluminum Siding, Soffit and Fascia 1404.5.1
* AAMA/WDMA/CSA 101/IS2/A440-08 Specifications for Windows, Doors and Unit Skylights 1714.5.1, 2405.5


 

ACI American Concrete Institute
P.O. Box 9094
Farmington Hills, MI 48333-9094
Standard
reference
number
Title Referenced
in code
section number
*216.1-97 Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies Table 720.1(2), 721.1
*318-05 Building Code Requirements for Structural Concrete 1604.3.2, Table 1704.3, 1704.4.1, Table 1704.4,
1708.3, 1805.4.2.6, 1805.9, 1808.2.23.1.1,
1808.2.23.2,1808.2.23.2.1, 1809.2.2.2.2,
1809.2.3.2, 1809.2.3.2.2, 1810.1.2.2, 1812.8,1901.2, 1901.3, 1901.4, 1902.1,
1903.1, 1904.1, 1904.2.1, 1904.2.2, 1904.2.3, 1904.3, 1904.4, 1905.1.1, 1905.2,
1905.3, 1905.4, 1905.5, 1905.6.2, 1905.6.3, 1905.6.4, 1905.6.5, 1905.7, 1905.8, 1905.9,
1905.10, 1905.11, 1905.12, 1905.13, 1906.1, 1906.2, 1906.3, 1906.4, 1907.1, 1907.2, 1907.3,
1907.4, 1907.5, 1907.6, 1907.7.1, 1907.7.2, 1907.7.3, 1907.7.4, 1907.7.5, 1907.8, 1907.9, 1907.10, 1907.11, 1907.12, 1907.13, 1908, 1908.1, 1908.1.1, 1908.1.2, 1908.1.3, 1908.1.4, 1908.1.5, 1908.1.6, 1908.1.7, 1908.1.8, 1908.1.9, 1908.1.10, 1908.1.11, 1908.1.12, 1908.1.13, 1908.1.14, 1908.1.15, 1908.1.16, 1909.1, 1909.3, 1909.4, 1909.5, 1909.6, 1912.1, 2108.3, 2205.3
*530-05 Building Code Requirements for Masonry Structures 1405.5, 1405.5.2, 1405.9, 1604.3.4, 1704.5,
1704.5.1, Table 1704.5.1, 1704.5.2, 1704.5.3,
Table 1704.5.3, 1708.1.1, 1708.1.2, 1708.1.3, 1708.1.4, 1812.7, 2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2103.13.6, 2106.1, 2106.1.1,
2106.1.1.1, 2106.1.1.2, 2106.1.1.3, 2106.3, 2106.4, 2106.5, 2106.6, 2107.1, 2107.2,
2107.3, 2107.4, 2107.5, 2107.6, 2107.7, 2107.8, 2108.1, 2108.2, 2108.3, 2108.4, 2109.1, 2109.2.3.1, 2109.7.3
*530.1-05 Specifications for Masonry Structures 1405.5.1, Table 1704.5.1, Table 1704.5.3,
1805.5.2.2, 2103.13.7, 2104.1, 2104.1.1, 2104.3, 2104.4


AF&PA American Forest & Paper Association
1111 19th St, NW Suite 800
Washington, DC 20036
Standard
reference
number
Title Referenced
in code
section number
WCD No. 4-89 Wood Construction Data-Plank and Beam Framing for Residential Buildings 2306.1.2
*WFCM-01 Wood Frame Construction Manual for One- and Two-family Dwellings 1609.1.1, 1609.1.1.12301.2, 2308.1, 2308.2.1
*PWF-07 Permanent Wood Foundation Design Specification 1805.4.6, 1807.2, 2304.9.5
*NDS-05 National Design Specification (NDS) for Wood Construction with 2005 Supplement 721.6.3.2, 1715.1.1, 1715.1.4, 1805.4.5, 1809.1.4, 2302.1, 2304.12, 2306.1, 2306.2.1, 2306.3.1, Table 2306.3.1, Table 2306.3.2, Table 2306.4.1,  Table 2306.4.4, 2306.3.4, 2306.3.5, 2306.4.1, 2307.1, 2307.1.1
AF&PA-93 Span Tables for Joists and Rafters 2306.1.1, 2308.8, 2308.10.2, 2308.10.3
SDPWS-05 AF&PA Supplement Special Design Provisions for Wind and Seismic 2305.1


AHA American Hardwood Association
1210 West N.W. Highway
Palatine, IL 60067
Standard
reference
number
Title Referenced
in code
section number
A135.4-04 Basic Hardboard 1404.3.1, 2303.1.6
A135.5-04 Prefinished Hardboard Paneling 2303.1.6, 2304.6.2
A135.6-98 Hardboard Siding 1404.3.2, 2303.1.6

 

AISC American Institute of Steel Construction
One East Wacker Drive, Suite 3100
Chicago, IL 60601-2001
Standard
reference
number
Title Referenced
in code
section number
*341-05 Seismic Provisions for Structural Steel Buildings, including
Supplement No. 1 dated 2006
1613.6.2, 1707.2, 1708.4, 2205.2.1, 2205.2.2, 2205.3, 2205.3.1
*360-05 Specification for Structural Steel Buildings 721.5.2.2.1, 1604.3.3, Table 1704.3, 2203.2, 2205.1, 2205.3

 

AISI American Iron and Steel Institute
1140 Connecticut Avenue
Suite 705
Washington, DC 20036
Standard
reference
number
Title Referenced
in code
section number
*NAS-01 North American Specification for the Design of Cold-formed
Steel Structural Members, including 2004 Supplement
1604.3.3, 2209.1, 2210.1
*General-04 Standard for Cold-formed Steel Framing-General Provisions 1604.3.3, 2209.1, 2210.1
1604.3.3, 2210.1
*Header-04 Standard for Cold-formed Steel Framing-Header Design 2210.2
*Lateral-04 Standard for Cold-formed Steel Framing-Lateral Design 2210.5, 2210.5.1
*PM-01 Standard for Cold-formed Steel Framing-Prescriptive Method for
One- and Two-family Dwellings, including 2004 Supplement
2210.6
*Truss-04 Standard for Cold-formed Steel Framing-Truss Design 1604.3.3, 2210.3
*WSD-04 Standard for Cold-formed Steel Framing-Wall Stud Design 2210.4

 

AITC American Institute of Timber Construction
Suite 140
7012 S. Revere Parkway
Englewood, CO 80112
Standard
reference
number
Title Referenced
in code
section number
AITC Technical Note 7-96 Calculation of Fire Resistance of Glued Laminated Timbers 721.6.3.3
*AITC 104-03 Typical Construction Details 2306.1
*AITC 110-01 Standard Appearance Grades for Structural Glued Laminated Timber 2306.1
*AITC 113-01 Standard for Dimensions of Structural Glued Laminated Timber 2306.1
AITC 117-04 Standard Specifications for Structural Glued Laminated Timber of Softwood Species 2306.1
AITC 119-96 Standard Specifications for Structural Glued Laminated Timber of Hardwood Species 2306.1
AITC 200-04 Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber 2306.1
ANSI/AITC A 190.1-02 Structural Glued Laminated Timber 2303.1.3, 2306.1

 

ALI Automotive Lift Institute
P.O. Box 85
Courtland, NY 13045
Standard
reference
number
Title Referenced
in code
section number
*ALI ALCTV-2006 Standard for Automotive Lifts-Safety Requirements for Construction, Testing and Validation (ANSI) 3001.2, 1011.3

 

ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A13.1-07 Scheme for the Identification of Piping Systems 415.8.6.4
*A108.1A-99 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar 2103.10
*A108.1B-99 Installation of Ceramic Tile, quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex-portland Mortar 2103.10
*A108.4-99 Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive 2103.10.6
*A108.5-99 Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-portland Cement Mortar 2103.10.1, 2103.10.2
*A108.6-99 Installation of Ceramic Tile with Chemical-resistant, Water Cleanable Tile-setting and -grouting Epoxy 2103.10.3
*A108.8-99 Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout 2103.10.4
*A108.9-99 Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout 2103.10.5
*A108.10-99 Installation of Grout in Tilework 2103.10.7
*A117.1-03 ICC/ANSI Accessible and Usable Buildings and Facilities 406.2.2, 907.9.1.4, 1007.6.5, 1010.1,  1010.6.5, 1010.9, 1011.3, 1101.2, 1102.1, 1103.2.14, 1106.1.1,  1106.7, 1107.2, 1107.2.1, 1107.2.2, 1108.2.2, 1109.1, 1109.2.1.1,  1109.2.2, 1109.3, 1109.4, 1109.8, 1607.7, 2902.5, 3001.3
A118.1-99 American NationalStandard Specifications for Dry-set Portland Cement Mortar 2103.10.1
A118.3-99 American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive 2103.10.3
A118.4-99 American National Standard Specifications for Latex-portland Cement Mortar 2103.10.2
A118.5-99 American National Standard Specifications for Chemical Resistant Furan Mortar and Grouts for Tile Installation 2103.10.4
A118.6-99 American National Standard Specifications for Cement Grouts for Tile Installation 2103.10.7
A118.8-99 American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout 2103.10.5
A136.1-99 American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile 2103.10.6
A137.1-88 American National Standard Specifications for Ceramic Tile 2103.5
A208.1-99 Particleboard 2303.1.7, 2303.1.7.1
Z 97.1-84 (R1994) Safety Glazing Materials Used in Buildings-Safety Performance Specifications and Methods of Test (Reaffirmed 1994) 2406.1.2, 2409.1

 

APA APA - Engineered Wood Association
7011 South 19th Street
Tacoma, WA 98466-5333
Standard
reference
number
Title Referenced
in code
section number
*APA PDS-08 Panel Design Specification 2306.1, 2306.3.1, 2306.4.1
*APA PDS
Supplement 1-90 (R95)
Design and Fabrication of Plywood Curved Panels (revised 1995) 2306.1
*APA PDS
Supplement 2-92 (R98)
Design and Fabrication of Plywood-lumber beams (revised 1998) 2306.1
*APA PDS
Supplement 3-90 (R96)
Design and Fabrication of Plywood Stressed-skin Panels (revised 1996) 2306.1
*APA PDS
Supplement 4-90 (R93)
Design and Fabrication of Plywood Sandwich Panels (revised 1993) 2306.1
*APA PDS
Supplement 5-08
Design and Fabrication of All-plywood Beams (revised 2008) 2306.1
*EWS R540-07 Builders Tips: Proper Storage and Handling of Glulam Beams 2306.1
*EWS S475-07 Glued Laminated Beam Design Tables   2306.1
*EWS S560-06 Field Notching and Drilling of Glued Laminated Timber Beams 2306.1
*EWS T300-07 Glulam Connection Details 2306.1
*EWS X440-08 Product Guide-Glulam 2306.1
EWS X450-01 Glulam in Residential Construction -Western Edition  2306.1

 

APSP The Association of Pool and Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA22314
Standard
reference
number
Title Referenced
in code
section number
*ANSI/APSP-7 2006 American National Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs, and Catch Basins 3109.6.1

 

ASAE American Society of Agricultural Engineers
2950 Niles Road
St. Joseph, MI 49085-9659
Standard
reference
number
Title Referenced
in code
section number
EP 484.2 (1998) Diaphragm Design of Metal-clad, Post-frame Rectangular Buildings 2306.1
*EP 486.1 (2000) Shallow-post Foundation Design 2306.1
EP 559 (1997) Design Requirements and Bending Properties for Mechanically Laminated Columns 2306.1

 

ASCE American Society of Civil Engineers
1801 Alexander Bell Drive
Reston, VA 20191-4400
Standard
reference
number
Title Referenced
in code
section number
*3-91 Structural Design of Composite Slabs 1604.3.3, 2209.2
*5-05 Building Code Requirements for Masonry Structures 1405.5, 1405.5.2, 1405.9, 1604.3.4, 1704.5, 1704.5.1,  Table 1704.5.1, 1704.5.2, 1704.5.3, Table 1704.5.3, 1708.1.1,  1708.1.2, 1708.1.3, 1708.1.4, 1812.7, 2101.2.2, 2101.2.3, 2101.2.4,  2101.2.5, 2101.2.6, 2103.13.6, 2106.1, 2106.1.1, 2106.1.1.1, 2106.1.1.2,  2106.1.1.3, 2106.3, 2106.4, 2106.5, 2106.6, 2107.1, 2107.2, 2107.3, 2107.4,  2107.5, 2107.6, 2107.7, 2170.8, 2108.1, 2108.2, 2108.3,  2108.4, 2109.1, 2109.2.3.1, 2109.7.3
*6-05 Specifications for Masonry Structures 1405.5.1, Table 1704.5.1, Table 1704.5.3,  1805.5.2.2, 2103.13.7, 2104.1, 2104.1.1, 2104.3, 2104.4
*7-05 Minimum Design Loads for Buildings and Other Structures including Supplement No. 1 and excluding Chapter 14 and Appendix 11A 1602.1, 1604.3, 1604.10, 1605.1, 1605.2.2,  1605.3.1.2, 1605.3.2, 1605.4, 1607.11.1, 1608.1,  1608.2, 1609.1.1, 1609.1.2, 1609.3, 1609.5.1, 1609.5.3, 1611.2,  1612.2, 1613.1, 1613.2, Table 1613.5.3(1), Table 1613.5.3(2), 1613.5.6,  1613.5.6.1, 1613.5.6.2, 1613.6, 1613.6.1, 1613.6.2, 1702.1, 1801.2.1, 1802.2.7,  1908.1.3, 2109.1.1 2205.2.1, 2205.3, 2205.3.1, 2208.1, 2305.1.5, 2305.2.5,   2305.3.1, 2306.4.5, Table 2306.4.5, Table 2308.10.1, 2404.1, 2505.1, 2505.2, 2506.2.1
8-02 Standard Specification for the Design of Cold-formed Stainless Steel Structural Members 1604.3.3, 2209.1
19-96 Structural Applications of Steel Cables for Buildings 2207.1, 2207.2
*24-05 Flood Resistant Design and Construction 1203.3.2, 1612.4, 1612.5, 3001.2
29-05 Standard Calculation Methods for Structural Fire Protection 721.1
*32-01 Design and Construction of Frost Protected Shallow Foundations 1805.2.1

 

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
A13.1-07 Scheme for Identification of Piping Systems 415.8.6.4
*A17.1-07 Safety Code for Elevators and Escalators 1007.4, 1607.8.1, 3001.2, 3001.4,  3002.5, 3003.2, 3005.2
*A18.1-05 Safety Standard for Platform Lifts and Stairway Chairlifts 1109.7, 2702.2.6, 3001.2, 3005.3
*A90.1-03 Safety Standard for Belt Manlifts 3001.2, 3005.4
A112.19.8-07 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, Hot Tubs and Whirlpool Bathing Appliances 3109.6.2.1
A112.19.17-02 Manufactured Safety Vacuum Release Systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub and Wading Pool 3109.6.2.2
B16.18-01 Cast Copper Alloy Solder Joint Pressure Fittings 909.13.1
B16.22-01 Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 909.13.1
*B20.1-03 Safety Standard for Conveyors and Related Equipment 3001.2, 3005.5
B31.3-02 Process Piping 415.8.6.1

 

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A 6/A 6M- 04a Specification for General Requirements for Rolled Steel, Structural Steel Bars, Plates, Shapes, and Sheet Piling Table 1704.3
A 36/A 36M-04 Specification for Carbon Structural Steel 1809.3.1, 2103.13.5
A 82-02 Specification for Steel Wire, Plain, for Concrete Reinforcement 2103.13.5, 2103.13.6
A 123/A 123M-02 Specification for Zinc (Hot-dip Galvanized) Coating on Iron and Steel Products 2103.13.7.2
A 153-03 Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware 2103.13.7.2, 2304.9.5
A 185-02 Specification for Steel Welded Wire Reinforcement, Plain for Concrete 2103.13.4, 2103.13.5
A 240-04 Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications Table 1507.4.3(1), 2103.13.5
A 252-98 (2002) Specification for Welded and Seamless Steel Pipe Piles 1809.3.1, 1810.6.1, 1810.8.2
A 283/A 283M-03 Specification for Low and Intermediate Tensile Strength Carbon Steel Plates 1809.3.1, 1810.6.1
A 307-03 Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength 1911.1, 2103.13.5
A 416/A 416M-02 Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete 1809.2.3.1, 2103.13.6
A 421/A 421M-02 Specification for Uncoated Stress-relieved Steel Wire for Prestressed Concrete 2103.13.6
*A 435/A 435M- 90 (2001) Specification for Straight-beam Ultrasonic Examination of Steel Plates 1708.4
A 463/A 463M-02a Specification for Steel Sheet, Aluminum-coated, by the Hot Dip Process Table 1507.4.3(2)
A 480/A480M-02 Specification for General Requirements for Flat-rolled Stainless and Heat-resisting Steel Plate, Sheet, and Strip 2103.13.5
A 496-02 Specification for Steel Wire, Deformed for Concrete Reinforcement 2103.13.3
A 497-01 Specification for Steel Welded Reinforcement Deformed, for Concrete 2103.13.4
A 510-03 Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon Steel 2103.13.6
A 568/A 568M-03 Specification for Steel, Sheet, Carbon, and High-strength, Low-alloy, Hot-rolled and Cold-rolled, General Requirements for Table 1704.3
A 572/A 572M-04 Specification for High-strength Low-alloy Columbium-vanadium Structural Steel 1809.3.1
A 588/A 588M-04 Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 Mpa) Minimum Yield Point to 4 inches (100 mm) Thick 1809.3.1
A 615/A 615M-04a Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement 1708.3, 1810.8.2, 1908.1.5, 2103.13.1, 2103.13.6
A 641/A 641M-03 Specification for Zinc-coated (Galvanized) Carbon Steel Wire 2103.13.7.1
A 653/A 653M-04a Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process Table 1507.4.3(1), Table 1507.4.3(2), 2103.13.7.1
A 690-00a Standard Specification for High Strength Low-alloy Steel H-piles and Sheet Piling for Use in Marine Environments 1809.3.1
A 706/A 706M-04a Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement 1704.4.1, Table 1704.3, 1908.1.5,  2103.13.1, 2103.13.6, 2108.3
A 722/A 722M- 98 (2003) Specification for Uncoated High-strength Steel Bar for Prestressing Concrete 1810.8.2, 2103.13.62106.1.1.3.1
A 755/A 755M-04 Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products Table 1507.4.3(1),  Table 1507.4.3(2)
A 767/A 767M-00b Specification for Zinc-coated (Galvanized) Steel Bars for Concrete Reinforcement 2103.13.1
A 775/A 775M-04 Specification for Epoxy-coated Steel Reinforcing Bars 2103.13.1
A 792/A 792M-03 Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process Table 1507.4.3(1), Table 1507.4.3(2)
A 875/A 875M-02a Standard Specification for Steel Sheet Zinc-5 percent, Aluminum Alloy-coated by the Hot-dip Process Table 1507.4.3(2)
A 884-02 Specification for Epoxy-coated Steel Wire and Welded Wire Fabric for Reinforcement 2103.13.7.3
A 898/A 898M- 91 (2001) Specification for Straight Beam Ultrasonic Examination of Rolled Steel Shapes 1708.4
A 899-91 (2002) Specification for Steel Wire Epoxy-coated 2103.13.7.3
A 913/A 913M-04 Specification for High-strength Low-alloy Steel Shapes of Structural Quality, Produced by Quenching and Self-tempering Process (QST) 1809.3.1
A924-04 Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process Table 1507.4.3(1)
A 951-02 Specification for Masonry Joint Reinforcement 2103.13.2
A 992-04a Standard Specification for Structural Shapes 1809.3.1
A 996/A 996M-04 Specification for Rail-steel and Axle-steel Deformed Bars for Concrete Reinforcement 2103.13.1, 2103.13.6
A1008/A1008M-04b Specification for Steel, Sheet, Cold-rolled, Carbon, Structural, High-strength Low-alloy and High-strength Low-alloy with Improved Formability 2103.13.5
B 42-02e01 Specification for Seamless Copper Pipe, Standard Sizes 909.13.1
B 43-04 Specification for Seamless Red Brass Pipe, Standard Sizes 909.13.1
B 68-02 Specification for Seamless Copper Tube, Bright Annealed (Metric) 909.13.1
B 88-03 Specification for Seamless Copper Water Tube 909.13.1
B 101-02 Specification for Lead-coated Copper Sheet and Strip for Building Construction Table 1404.5.3, Table 1507.2.9.2, Table 1507.4.3(1)
B 209-04 Specification for Aluminum and Aluminum Alloy Steel and Plate Table 1507.4.3(1)
B 251-02e01 Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube 909.13.1
B 280-03 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service 909.13.1
B 370-03 Specification for Cold-rolled Copper Sheet and Strip for Building Construction 1404.5.2, Table 1507.2.9.2Table 1507.4.3(1)
B 695-00 Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel 2304.9.5
C 5-03 Specification for Quicklime for Structural Purposes Table 2507.2
C 22/C 22M-00 Specification for Gypsum Table 2506.2
C 27-98 (2002) Specification for Standard Classification of Fireclay and High-alumina Refractory Brick 2111.5, 2111.8
C 28/C 28M-00e01 Specification for Gypsum Plasters Table 2507.2
C 31/31M-03a Practice for Making and Curing Concrete Test Specimens in the Field Table 1704.4
C 33-03 Specification for Concrete Aggregates 721.3.1.4, 721.4.1.1.3
C 34-03 Specification for Structural Clay Load-bearing Wall Tile 2103.2
C 35-95 (2001) Specification for Inorganic Aggregates for Use in Gypsum Plaster Table 2507.2
C 36/C 36M-03 Specification for Gypsum Wallboard Figure 721.5.1(2), Figure 721.5.1(3), Table 2506.2
C 37/C 37M-01 Specification for Gypsum Lath Table 2507.2
C 55-03 Specification for Concrete Brick Table 721.3.2, 2103.1, 2105.2.2.1.2
C 56-96 (2001) Specification for Structural Clay Non-load Bearing Tile 2103.2
C 59/C 59M-00 Specification for Gypsum Casting and Molding Plaster Table 2507.2
C 61/C 61M-00 Specification for Gypsum Keene's Cement Table 2507.2
C 62-04 Specification for Building Brick (Solid Masonry Units Made from Clay or Shale) 1805.5.2.2, 2103.22105.2.2.1.1
C 67-03ae01 Test Methods of Sampling and Testing Brick and Structural Clay Tile 721.4.1.1.1, 2104.5, 2105.2.2.1.1,  2109.8.1.1
C 73-99a Specification for Calcium Silicate Face Brick (Sand-lime Brick) Table 721.3.2, 2103.1
C 79/C79M-04a Specification for Treated Core and Nontreated Core Gypsum Sheathing Board Table 2506.2
C 90-03 Specification for Loadbearing Concrete Masonry Units Table 721.3.2, 1805.5.2.2, 2103.1, 2105.2.2.1.2
C 91-03a Specification for Masonry Cement Table 2103.8(1), Table 2507.2
C 94/C 94M-04 Specification for Ready-mixed Concrete 109.3.1
C109/C109M-02 Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens) 2103.11.1
C 126-99 Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units 2103.2
C 140-03 Test Method Sampling and Testing Concrete Masonry Units and Related Units 721.3.1.2, 2105.2.2.1.2
C 150-04 Specification for Portland Cement Table 2103.8(1), Table 2507.2
C 172-04 Practice for Sampling Freshly Mixed Concrete Table 1704.4
C 199-84 (2000) Test Method for Pier Test for Refractory Mortars 2111.5, 2111.8, 2113.12
C 206-03 Specification for Finishing Hydrated Lime Table 2507.2
C 207-04 Specification for Hydrated Lime for Masonry Purposes Table 2103.8(1)
C 208-95 (2001) Specification for Cellulosic Fiber Insulating Board Table 1508.2, 2303.1.5
C 212-00 Specification for Structural Clay Facing Tile 2103.2
C 216-04a Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) 1805.5.2.2, 2103.2, 2105.2.2.1.1
C 270-04 Specification for Mortar for Unit Masonry 2103.8, Table 2103.8(2)
C 315-02 Specification for Clay Flue Linings 2113.11.1, Table 2113.16(1)
C 317/C 317M-00 Specification for Gypsum Concrete 1914.1
C 330-04 Specification for Lightweight Aggregates for Structural Concrete 721.1.1
C 331-04 Specification for Lightweight Aggregates for Concrete Masonry Units 721.3.1.4, 721.4.1.1.3
C 406-00 Specification for Roofing Slate 1507.7.4
C 442/C 442M-04 Specification for Gypsum Backing Board and Coreboard and Gypsum Shaftliner Board Table 2506.2
C 472- 99 (2004) Specification for Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete Table 2506.2
C 473-03 Test Method for Physical Testing of Gypsum Panel Products Table 2506.2
C 474-02 Test Methods for Joint Treatment Materials for Gypsum Board Construction Table 2506.2
C 475/ C475M-02 Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard Table 2506.2
C 476-02 Specification for Grout for Masonry 2103.12, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
C 503-03 Specification for Marble Dimension Stone (Exterior) 2103.4
C 514-01 Specification for Nails for the Application of Gypsum Board Table 720.1(2), Table 720.1(3),  Table 2306.4.5, Table 2506.2
C 516-02 Specifications for Vermiculite Loose Fill Thermal Insulation 721.3.1.4, 721.4.1.1.3
C 547-03 Specification for Mineral Fiber Pipe Insulation Table 720.1(2), Table 720.1(3)
C 549-02 Specification for Perlite Loose Fill Insulation 721.3.1.4, 721.4.1.1.3
C 552-03 Standard Specification for Cellular Glass Thermal Insulation Table 1508.2
C 557-03 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing Table 2506.2
C 568-03 Specification for Limestone Dimension Stone 2103.4
C 578-04 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation Table 1508.2
C 587-02 Specification for Gypsum Veneer Plaster Table 2507.2
C 588/C 588M-01 Specification for Gypsum Base for Veneer Plasters Table 2507.2
C 595-03 Specification for Blended Hydraulic Cements Table 2103.8(1), Table 2507.2
C 615-03 Specification for Granite Dimension Stone 2103.4
C 616-03 Specification for Quartz Dimension Stone 2103.4
C 629-03 Specification for Slate Dimension Stone 2103.4
C 630/C 630M-03 Specification for Water-resistant Gypsum Backing Board Table 2506.2
C 631-95a (2000) Specification for Bonding Compounds for Interior Gypsum Plastering Table 2507.2
*C 635-00 Specification for the Manufacturer, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings 803.9.1.1, 2506.2.1
C 636-04 Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels 803.9.1.1
C 645-04 Specification for Nonstructural Steel Framing Members Table 2506.2, Table 2507.2
C 652-04a Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale) 1805.5.2.2, 2103.2, 2105.2.2.1.1
C 728-97E1 Standard Specification for Perlite Thermal Insulation Board Table 1508.2
C 744-99 Specification for Prefaced Concrete and Calcium Silicate Masonry Units 2103.1
C 754-04 Specification for Installation of Steel Framing Members to Receive Screw-attached Gypsum Panel Products  Table 2508.1, Table 2511.1
C 836-03 Specification for High-solids Content, Cold Liquid-applied Elastomeric  Waterproofing Membrane for Use with Separate Wearing Course 1507.15.2
*C 840-01 Specification for Application and Finishing of Gypsum Board Table 2508.1, 2509.2
C 841-03 Specification for Installation of Interior Lathing and Furring Table 2508.1, Table 2511.1
C 842-99 Specification for Application of Interior Gypsum Plaster Table 2511.1, 2511.3, 2511.4
C 843-99e01 Specification for Application of Gypsum Veneer Plaster Table 2511.1
C 844-99 Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster Table 2508.1
C 847-00 Specification for Metal Lath Table 2507.2
C 887-79a (2001) Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar 1807.2.2, 2103.9
C 897-00 Specification for Aggregate for Job-mixed Portland Cement-based Plasters Table 2507.2
C 926-98a Specification for Application of Portland Cement Based-plaster 2109.8.4.6, 2510.3, Table 2511.1, 2511.3, 2511.4, 2512.1, 2512.1.2, 2512.22512.6, 2512.8.2, 2512.9, 2513.7
C 931/C 931M-04 Specification for Exterior Gypsum Soffit Board Table 2506.2
C 932-03 Specification for Surface-applied Bonding Agents for Exterior Plastering Table 2507.2
C 933-04 Specification for Welded Wire Lath Table 2507.2
*C 946-91 (2001) Specification for Practice for Construction of Dry-stacked, Surface-bonded Walls 2103.9, 2109.2.3.2
C 954-00 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to 0.112 inch (2.84 mm) in Thickness Table 2506.2, Table 2507.2
C 955-03 Standard Specification for Load-bearing Transverse and Axial Steel Studs, Runners Tracks, and Bracing or Bridging, for Screw Application of Gypsum Panel Products and Metal Plaster Bases Table 2506.2, Table 2507.2
C 956-04 Specification for Installation of Cast-in-place Reinforced Gypsum Concrete 1914.1
C 957-04 Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane with Integral Wearing Surface 1507.15.2
C 960/ C960M-04 Specification for Predecorated Gypsum Board Table 2506.2
C1002-01 Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs Table 2506.2, Table 2507.2
C1006-84 (2001) Test Method for Splitting Tensile Strength of Masonry Units 2103.11.1
*C1007-00 Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories Table 2508.1, Table 2511.1
C1019-03 Test Method of Sampling and Testing Grout 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
C1029-02 Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation 1507.14.2
C1032-04 Specification for Woven Wire Plaster Base Table 2507.2
C1047-99 Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base Table 2506.2, Table 2507.2
C1063-03 Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement Based Plaster 2109.8.4.6, 2510.3, Table 2511.1, 2512.1.1
C 1072-00a Standard Text Method for Measurement of Masonry Flexural Bond Strength 2103.11.1
C1088-02 Specification for Thin Veneer Brick Units Made from Clay or Shale 2103.2
C1167-03 Specification for Clay Roof Tiles 1507.3.4
C1177/C1177M-04 Specification for Glass Mat Gypsum Substrate for Use as Sheathing Table 2506.2
C1178/C1178M-04 Specification for Glass Mat Water-resistant Gypsum Backing Panel Table 2506.2, 2509.2
C1186-02 Specification for Flat Nonasbestos Fiber Cement Sheets 1404.10
C1261-04 Specification for Firebox Brick for Residential Fireplaces 2111.5, 2111.8
C1278/C 1278M-03 Specification for Fiber-reinforced Gypsum Panels Table 2506.2
C1280-04 Specification for Application of Gypsum Sheathing Table 2508.1, 2508.2
*C1283-00e01 Practice for Installing Clay Flue Liners 2113.12
C1288-01 Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets 2509.2
C1289-03 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board Table 1508.2
C1314-03b Test Method for Compressive Strength of Masonry Prisms 2105.2.2.2.2, 2105.3.1, 2105.3.2
C1325-04 Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate Sheets 2509.02
C1328-03a Specification for Plastic (Stucco Cement) Table 2507.2
C1329-04 Specification for Mortar Cement Table 2103.8(1)
C1386-98 Specification for Precast Autoclaved Aerated Concrete (PAAC) Wall Construction Units 2102.1, 2103.3, 2105.2.2.1.3
C1395/1395M-04 Specification for Gypsum Ceiling Board Table 2506.2
C1396/C1396M-04 Standard Specifications for Gypsum Board Table 2506.2
C1405-00a Standard Specification for Glazed Brick (Single Fired, Solid Brick Units) 2103.2
C1492-03 Standard Specification for Concrete Roof Tile 1507.3.5
D 25-99E01 Specification for Round Timber Piles 1809.1.1, 2303.1.11
D 41-94 (2000) e01 Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 43-00 Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 56-02a Test Method for Flash Point By Tag Closed Tester 307.2
D 86-04b Test Method for Distillation of Petroleum Products at Atmospheric Pressure 307.2
D 93-02a Test Method for Flash Point By Pensky-Martens Closed Cup Tester 307.2
D 225-04 Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules 1507.2.5
D 226-97a Specification for Asphalt-saturated Organic Felt Used in Roofing and Waterproofing 1404.2, 1507.2.3, 1507.3.3, 1507.5.3, 1507.6.3, 1507.7.3,  Table 1507.8, 1507.8.3, 1507.9.3, 1507.9.4, Table 1507.10.2
D 227-03 Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing Table 1507.10.2
D 312-00 Specification for Asphalt Used in Roofing Table 1507.10.2
D 422-63 (2002) Test Method for Particle-size Analysis of Soils 1802.3.2
D 450-96 (2000)e01 Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 635-03 Test Method for Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastics in a Horizontal Position 2606.4
D1143-81 (1994) E01 Test Method for Piles Under Static Axial Compressive Load 1808.2.8.3
D1227-00 Specification for Emulsified Asphalt Used as a Protective Coating for Roofing Table 1507.10.2, 1507.15.2
D1557-02 Test Method for Laboratory Compaction Characteristics of Soil Using Modified Effort [56,000 ft-lb/ft3 (2,700 KN m/m 3)] 1803.5
D1586-99 Specification for Penetration Test and Split-barrel Sampling of Soils 1613.5.5
D1761-88 (2000) e01 Test Method for Mechanical Fasteners in Wood 1715.1.1, 1715.1.2, 1715.1.3
D1863-03 Specification for Mineral Aggregate Used on Built-up Roofs Table 1507.10.2
D1929-96 (2001)e01 Test Method for Determining Ignition Properties of Plastics 402.15.4, 406.5.2, 1407.11.2.1, 2606.4
D1970-01 Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection 1507.2.4, 1507.2.9.2, 1507.3.9,  1507.5.6, 1507.8.7, 1507.9.8
D2166-00 Test Method for Unconfined Compressive Strength of Cohesive Soil 1613.5.5
D2178-97a Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D2216-98 Test Method for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass 1613.5.5
D2487-00 Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System) Table 1610.1, 1802.3.1
D2626-04 Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing 1507.3.3, Table 1507.10.2
D2822-91 (97)e01 Specification for Asphalt Roof Cement Table 1507.10.2
D2823-90 (97) e1 Specification for Asphalt Roof Coatings Table 1507.10.2
D2843-99 (2004) Test for Density of Smoke from the Burning or Decomposition of Plastics 2606.4
D2850-03a Test Method for Unconsolidated, Undrained Triaxial Compression Test on Cohesive Soils 1613.5.5
D2898-94 (1999) Test Methods for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing 1505.1, 2303.2.1, 2303.2.3
D3019-e01(Supp) Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered Table 1507.10.2
D3161-03b Test Method for a Wind Resistance of Asphalt Shingles (Fan Induced Method) 1504.1.1, 1507.2.5
D3200-74 (2000) Standard Specification and Test Method for Establishing Recommended Design Stresses for Round Timber Construction Poles 2303.1.11
D3201-94 (2003) Test Method for Hygroscopic Properties of Fire-retardant-treated Wood and Wood-based Products 2303.2.4
D3278-96e1 Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 307.2
D3462-04 Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules 1507.2.5
D3468-99 Specification for Liquid-applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing 1507.15.2
D3679-04 Specification for Rigid Poly [Vinyl Chloride (PVC) Siding] 1404.9, 1405.13
D3689-90 (1995) Method for Testing Individual Piles Under Static Axial Tensile Load 1808.2.8.5
D3737-03 Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam) 2303.1.3
D3746-85 (2002) Test Method for Impact Resistance of Bituminous Roofing Systems 1504.7
D3747-79 (2000)e1 Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table 1507.10.2
D3909-97b Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules 1507.2.9.2, 1507.6.4, Table 1507.10.2
D 3957-03 Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings 2303.1.10
D4022-94 (2000)e01 Specification for Coal Tar Roof Cement, Asbestos Containing Table 1507.10.2
D4272-03 Test Method for Total Energy Impact of Plastic Films by Dart Drop 1504.7
D4318-00 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils 1613.5.5, 1802.3.2
D4434-04 Specification for Poly (Vinyl Chloride) Sheet Roofing 1507.13.2
D4479-00 Specification for Asphalt Roof Coatings-Asbestos-free Table 1507.10.2
D4586-00 Specification for Asphalt Roof Cement, Asbestos-free Table 1507.10.2
D4601-98 Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table 1507.10.2
D4637-04 Specification for EPDM Sheet Used in Single-ply Roof Membrane 1507.12.2
D4829-03 Test Method for Expansion Index of Soils 1802.3.2
D4869-04 Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing 1507.2.3, 1507.5.3, 1507.6.3,  1507.7.3, 1507.8.3, 1507.9.3
D4897-01 Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing Table 1507.10.2
D4945-00 Test Method for High-strain Dynamic Testing of Piles 1808.2.8.3
D4990-97a Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D5019-96e01 Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane 1507.12.2
D5055-04 Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-Joists 2303.1.2
D5456-03 Specification for Evaluation of Structural Composite Lumber Products 2303.1.9
D5516-03 Test Method of Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures 2303.2.2.1
D5643-94 (2000)e01 Specification for Coal Tar Roof Cement, Asbestos-free Table 1507.10.2
D5664-02 Test Methods for Evaluating the Effects of Fire-retardant Treatment and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber 2303.2.2.2
D5665-99a Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing Table 1507.10.2
D5726-98 Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing Table 1507.10.2
D6083-97a Specification for Liquid Applied Acrylic Coating Used in Roofing Table 1507.10.2, 1507.15.2
D6162-00A Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements 1507.11.2
D6163-00 E01 Specification for Styrene-Butadiene-Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements 1507.11.2
D6164-00 Specification for Styrene-Butadiene-Styrene (SBS) Modified Bituminous Sheet Metal Materials Using Polyester Reinforcements 1507.11.2
D6222-02 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements 1507.11.2
D6223-02 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements 1507.11.2
D6298-00 Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface 1507.11.2
D6305-02e01 Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing 2303.2.2.1
D6380-01E1 Standard Specification for Asphalt Roll Roofing (Organic) Felt 1507.2.9.2, 1507.3.3, 1507.6.4
D6381-03 Standard Test Method for Measurement of Asphalt Shingle Mechanical Uplift Resistance 1504.2.1, Table 1504.2.1, 1609.5.2
D6694-01 Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing 1507.15.2
D6754-02 Standard Specification for Ketone Ethylene Ester Based Sheet Roofing 1507.13.2
D6757-02 Standard Specification for Inorganic Underlayment for Use with Steep Slope Roofing Products 1507.2.3
D6841-03 Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber 2303.2.2.2
D6878-03 Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing 1507.13.2
E 72-02 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction 2103.11.1
E 84-05 Test Methods for Surface Burning Characteristics of Building Materials 402.10, 402.15.4, 406.5.2, 410.3.5.3,  703.4.2, 719.1, 719.4, 802.1, 803.1,  803.5, 803.6.1, 806.5, 1407.9, 1407.10.1,  2303.2, 2603.3, 2603.4.1.13, 2603.5.4,  2604.2.4, 2606.4, 3105.4
E 90-04 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements 1207.2
E 96-00 Test Method for Water Vapor Transmission of Materials 202, 1203.2
E 108-04 Test Methods for Fire Tests of Roof Coverings 1505.1, 2603.6, 2610.2, 2610.3
E 119-08a Test Methods for Fire Tests of Building Construction and Materials 410.3.5.2, 703.2, 703.2.1, 703.2.3, 703.3,  704.7, 704.9, 706.2.1, 706.7, 711.3.2, 712.3.1712.4.1.1, 713.1, 713.4, 714.7, 715.2, 716.5.2716.5.3, 716.6.1, 716.6.2, Table 720.1(1), 1407.10.2, 2103.2, 2603.4, 2603.5.1
E 136-99e01 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 703.4.1
E 328-02 Methods for Stress Relaxation for Materials and Structures 2103.13.6
E 330-02 Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference 1714.5.2
E 331-00 Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference 1403.2
E 492-04 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling Assemblies Using the Tapping Machine 1207.3
E 518-03 Standard Test Methods for Flexural Bond Strength of Masonry 2101.3.11.1
E 519-07 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages 2103.11.1
E 605-00 Test Method for Thickness and Density of Sprayed Fire-resistive Material (SFRM) Applied to Structural Members 1704.10.3, 1704.10.3.1, 1704.10.3.2, 1704.10.4
E 681-04 Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases 307.2
E 736-00 Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to Structural Members 1704.10.5
E 814-02 Test Method of Fire Tests of Through-penetration Firestops 702.1, 712.3.1.2, 712.4.1.1.2
E 970-00 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source 719.3.1
E1300-04e01 Practice for Determining Load Resistance of Glass in Buildings 2404.1, 2404.2, 2404.3.1, 2404.3.2,  2404.3.3, 2404.3.4, 2404.3.5
E1592-01 Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference 1504.3.2
*E1602-01 Guide for Construction of Solid Fuel-burning Masonry Heaters 2112.2
E1886-04 Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missiles and exposed to Cyclic Pressure Differentials 1609.1.2
E1966-00 Test Method for Fire-resistant Joint Systems 702.1, 713.3
E1996-04 Specification for Performance of Exterior Windows, Glazed Curtain Walls, Doors and Storm Shutters Impacted by Windborne Debris in Hurricanes 1609.1.2, 1609.1.2.1
E 2307-04 Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Intermediate-scale, Multistory Test Apparatus 713.4
F 547-01 Terminology of Nails for Use with Wood and Wood-based Materials Table 2506.2
F1346-91 (1996) Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs 3109.4, 3109.4.1.8, 3109.5, 3109.7.1
F1667-03 Specification for Driven Fasteners: Nails, Spikes and Staples Table 720.1(2), Table 720.1(3),  1507.2.6, 2303.6, Table 2506.2
F2208-08 Standard Specification for Pool Alarms 3109.7.1
F2387-04 Standard Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming Pools, Spas and Hot Tubs 3109.6.2.2
G 152-04 Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6
G 154-00A Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials 1504.6
G 155-04 Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6

 

AWCI The Association of the Wall and Ceiling Industries International
513 West Broad Street, Suite 210
Falls Church, VA 22046
Standard
reference
number
Title Referenced
in code
section number
*12-B-04 Second Edition Technical Manual 12-B Standard Practice for the Testing and
Inspection of Field Applied Thin-Film Intumescent Fire-Resistive
Materials; an Annotated Guide, Second Edition
1704.11

 

AWPA American Wood-Preservers' Association
P.O. Box 5690
Grandbury, TX 76049
Standard
reference
number
Title Referenced
in code
section number
C1-00 All Timber Products-Preservative Treatment by Pressure Processes 1505.6
M4-02 Standard for the Care of Preservative-treated Wood Products
USE CATEGORY SYSTEM: User
1809.1.2, 2303.1.8
U1-04 Specification for Treated Wood Except Section 6, Commodity
Specification H
1403.5, Table 1507.9.5, 1805.4.5, 1805.4.6,
 1805.7.1, 1809.1.2, 2303.1.8, 2304.11.2, 2304.11.4,
 2304.11.6, 2304.11.7

 

AWS American Welding Society
550 N.W. LeJeune Road
Miami, FL 33126
Standard
reference
number
Title Referenced
in code
section number
D1.1-04 Structural Welding Code-Steel Table 1704.3, 1704.3.1, 1708.4
D1.3-98 Structural Welding Code-Sheet Steel Table 1704.3
D1.4-98 Structural Welding Code-Reinforcing Steel Table 1704.3, Table 1704.4, 2107.6

 

BHMA Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York, NY 10017-6603
Standard
reference
number
Title Referenced
in code
section number
A 156.10-05 American National Standard for Power Operated Pedestrian Doors 1008.1.3.2
*A 156.19-02 Standard for Power Assist and Low Energy Power Operated Doors 1008.1.3.2

 

CGSB Canadian General Standards Board
222 Queens Street
14th Floor, Suite 1402
Ottawa, Ontario, Canada KIA 1G6
Standard
reference
number
Title Referenced
in code
section number
37-GP-52M (1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric 1504.7, 1507.12.2
37.54-95 Polyvinyl Chloride Roofing and Waterproofing Membrane 1507.13.2
37-GP-56M (1980) Membrane, Modified, Bituminous, Prefabricated and Reinforced for
Roofing- with December 1985 Amendment
1507.11.2

 

CPSC Consumer Product Safety Commission
4330 East West Highway
Bethesada, MD 20814-4408
Standard
reference
number
Title Referenced
in code
section number
16 CFR Part 1201(1984) Safety Standard for Architectural Glazing Material 2406.1.1, 2406.2.1, 2407.1, 2408.2.1, 2408.3
16 CFR Part 1209 (1979) Interim Safety Standard for Cellulose Insulation 719.6
16 CFR Part 1404 (1984) Cellulose Insulation 719.6
16 CFR Part 1500 (2010) Hazardous Substances and Articles; Administration and Enforcement Regulations 307.2
*16 CFR Part 1500.44 (2001) Method for Determining Extremely Flammable and Flammable Solids 307.2
16 CFR Part 1507 (2001) Fireworks Devices 307.2
16 CFR Part 1630 (2007) Standard for the Surface Flammability of Carpets and Rugs 804.4.1

 

CSA Canadian Standards Association
5060 Spectrum Way, Suite 100
Mississauga, Ontario, L4W 5N6 Canada
Standard
reference
number
Title Referenced
in code
section number
*AAMA/WDMA/CSA
101/I.S.2/A440-08
Specifications for Windows, Doors and Unit Skylights 1714.5.1, 2405.5

 

CSSB Cedar Shake and Shingle Bureau
P.O. Box 1178
Sumas, WA 98295-1178
Standard
reference
number
Title Referenced
in code
section number
CSSB-97 Grading and Packing Rules for Western Red Cedar Shakes and
Western Red Shingles of the Cedar Shake and Shingle Bureau
Table 1507.8.4, Table 1507.9.5

 

DASMA Door and Access Systems Manufacturers
Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
Standard
reference
number
Title Referenced
in code
section number
107-98 (03) Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation 2603.4.1.9

 

DOC U.S. Department of Commerce
National Institute of Standards and Technology
100 Bureau Drive Stop 3460
Gaithersburg, MD 20899
Standard
reference
number
Title Referenced
in code
section number
PS-1-95 Construction and Industrial Plywood 2303.1.4, 2304.6.2, Table 2304.7(4),
 Table 2304.7(5), 2306.3.1, Table 2306.3.1, Table 2306.3.2
PS-2-92 Performance Standard for Wood-based Structural-use Panels 2303.1.4, 2304.6.2, Table 2304.7(5),
 Table 2306.3.1, 2306.3.1, Table 2306.3.2
PS 20-99 American Softwood Lumber Standard 1809.1.1, 2302.1, 2303.1.1
 
 

DOL U.S. Department of Labor
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
29 CFR Part 1910.1000 Air Contaminans 902.1  
 
 

DOTn U.S. Department of Transportation
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
49 CFR-2009 Specification of Transportation of Explosive and Other Dangerous
Articles, UN 0335,UN 0336 Shipping Containers
307.2
49 CFR Parts 173.137
(2009)
Shippers-General Requirements for Shipments and Packaging-Class 8-Assignment of Packing Group 307.2

 

FEMA Federal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington, DC 20472
Standard
reference
number
Title Referenced
in code
section number
*FIA-TB11-01 Crawlspace Construction for Buildings Located in Special Flood Hazard Areas 1807.1.2.1

 

FM Factory Mutual
Standards Laboratories Department
1151 Boston-Providence Turnpike
Norwood, MA 02062
Standard
reference
number
Title Referenced
in code
section number
4450 (1989) Approval Standard for Class 1 Insulated Steel Deck Roofs-with
Supplements through July 1992
1504.3.1, 1508.1, 2603.3, 2603.4.1.5
4470 (1992) Approval Standard for Class 1 Roof Covers 1504.3.1, 1504.7
*4880 (2001) American National Standard for Evaluating Insulated Wall or Wall and
Roof/Ceiling Assemblies, Plastic Interior Finish Materials, Plastic
Exterior Building Panels, Wall/Ceiling Coating Systems, Interior and
Exterior Finish Systems
2603.4, 2603.9

 

GA Gypsum Association
810 First Street N.E. #510
Washington, DC 20002-4268
Standard
reference
number
Title Referenced
in code
section number
GA 216-04 Application and Finishing of Gypsum Board Table 2508.1, 2509.2
GA 600-03 Fire-Resistance Design Manual, 17th Edition Table 720.1(1), Table 720.1(2), Table 720.1(3)

 

HPVA Hardwood Plywood Veneer Association
1825 Michael Faraday Drive
Reston, VA 20190-5350
Standard
reference
number
Title Referenced
in code
section number
HP-1-2000 The American National Standard for Hardwood and Decorative Plywood 2303.3, 2304.6.2

 

ICC International Code Council
5203 Leesburg Pike, Suite 600
Falls Church, VA 22041
Standard
reference
number
Title Referenced
in code
section number
*ICC/ANSI A117.1-03 Accessible and Usable Buildings and Facilities 406.2.2, 907.9.1.4,1007.6.5,  1010.1, 1010.6.5, 1010.9, 1011.3, 1101.2, 1102.1, 1103.2.14, 1106.1.1,  1106.7, 1107.2, 1107.2.1, 1107.2.2, 1108.2.2, 1109.1, 1109.2.1.1,  1109.2.2, 1109.3, 1109.4, 1109.8, 1607.7, 2902.5, 3001.3
*ICC 300-02 ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands 1025.1.1
ECCCNYS-10 Energy Conservation Construction Code of New York State 101.4.7, 1203.3.2, 1301.1.1, 1403.2, 1403.7
EBCNYS-10 Existing Building Code of New York State 101.4.8, 102.3, 102.8, 1009.3, 1103.2.2, 1107.7.1.3,  1107.7.1.4, 1510.1, 1613.3
FCNYS-10 Fire Code of New York State 101.4.6, 102.8, 103.4, 105.1, 201.3, 307.1, 307.1.1, 307.2, Table 307.1(1),  Table 307.1(2), 404.2, 406.5.1, 406.6.1, 410.3.6, 411.1, 412.4.1, 413.1, 414.1.1, 414.1.2,  414.1.2.1, 414.2, 414.2.5, Table 414.2.5(1), Table 414.2.5(2), 414.3, 414.5, 414.5.1,  Table 414.5.1, 414.5.2, 414.5.4, 414.5.5, 414.6, 415.1, 415.2, 415.3, 415.3.1, Table 415.3.1,  Table 415.3.2, 415.6, 415.6.1, 415.6.1.4, 415.6.2, 415.6.2.3, 415.6.2.5, 415.6.2.7, 415.6.2.8,  415.6.2.9, 415.6.3, 415.6.3.3.3, 415.6.3.5, 415.6.4, 415.7, 415.8.1, 415.8.2.7, 415.8.5.1, 415.8.7.2,  415.8.9.3, 415.8.10.1, 416.1, 420.1, 420.7, 501.3, 501.4, 704.8.2, 706.1, 901.2, 901.3, 901.5, 901.6.2,  903.2.6.1, 903.2.11, Table 903.2.13, 903.5, 904.2.1, 905.1, 905.3.6, 906.1, 907.2.5, 907.2.12.2, 907.2.14,  907.2.16, 907.14, 907.19, 909.20, 910.2.2, Table 910.3, 1001.3, 1203.4.2, 1203.5, 2603.4.1.12,  2702.1, 2702.2.9, 2702.2.11, 2702.2.12, 2702.2.13, 2702.3, 3102.1, 3103.1, 3309.2,
FGCNYS-10 Fuel Gas Code of New York State 101.4.2, 201.3, Table 307.1(1), 415.6.3,  2113.11.1.2, 2113.15, 2801.1
MCNYS-10 Mechanical Code of New York State 101.4.3, 201.3, 307.1, Table 307.1(1), 406.4.2, 406.6.3, 406.6.5, 409.3,  412.4.6, 414.1.2, 414.3, 415.6.1.4, 415.6.2, 415.6.2.8, 415.6.3, 415.6.4, 415.8.11.1, 416.3,  420.5, 603.1, 603.1.1, 603.1.2, 707.2, 716.2.2, 716.5.4, 716.6.1, 716.6.2, 716.6.3, 717.5, 719.1,719.7,  903.2.12.1, 904.2.1, 904.11, 908.6, 909.1, 909.10.2, 1015.5, 1017.4.1, 1203.1, 1203.2.1, 1203.4.2,
 1203.4.2.1, 1203.5, 1209.3, 2304.5, 2801.1, 3004.3.1, 3401.3, 3410.6.7.1, 3410.6.8, 3410.6.8.1
PCNYS-10 Plumbing Code of New York State 101.4.4, 201.3, 415.6.4, 603.1.2, 717.5, 903.3.5, 912.5,  1006.3, 1206.3.3, 1503.4, 1807.4.3, 2901.1, Table 2902.1, 3305.1
PMCNYS-10 Property Maintenance Code of New York State 101.4.5, 102.6, 103.3, 3401.3, 3410.3.2.
RCNYS-10 Residential Code of New York State 101.2, 308.2, 308.3, 308.5, 310.1, 2308.1
*SBCCI SSTD 10-99 Standard for Hurricane Resistant Residential Construction 1609.1.1, 1609.1.1.1, 2308.2.1
SBCCI SSTD 11-97 Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles 1715.2.1, 1715.2.2

 

ISO International Standards Organization
ISO Central Secretariat1, rue de Varembee, Case postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
Title Referenced
in code
section number
ISO 8115-86 Cotton Bales-Dimensions and Density Table 415.8.2.1.1

 

NAAMM National Association of Architectural
Metal Manufacturers
8 South Michigan Ave
Chicago, IL 60603
Standard
reference
number
Title Referenced
in code
section number
FP 1001-97 Guide Specifications for Design of Metal Flag Poles 1609.1.1

 

NCMA National Concrete Masonry Association
2302 Horse Pen Road
Herndon, VA 22071-3499
Standard
reference
number
Title Referenced
in code
section number
TEK 5-84 (1996) Details for Concrete Masonry Fire Walls Table 720.1(2)

 

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Standard
reference
number
Title Referenced
in code
section number
*11-05 Standard for Low, Medium and High Expansion Foam 904.7
*12-08 Carbon Dioxide Extinguishing Systems 904.8, 904.11
*12A-04 Halon 1301 Fire Extinguishing Systems 904.9
*13-07 Installation of Sprinkler Systems 707.2, 903.3.1.1, 903.3.2, 903.3.5.1.1, 903.3.5.2,  904.11, 905.3.4, 907.8, 3104.5, 3104.9
*13D-07 Installation of Sprinkler Systems in One-and Two-family Dwellings and
 Manufactured Homes
903.3.1.3, 903.3.5.1.1
*13R-07 Installation of Sprinkler Systems in Residential Occupancies Up to
and Including Four Stories in Height
903.3.1.2, 903.3.5.1.1, 903.3.5.1.2, 903.4
*14-07 Installation of Standpipe and Hose System 905.2, 905.3.4, 905.4.2, 905.8
*16-07 Installation Foam-water Sprinkler and Foam-water Spray Systems 904.11
*17-09 Dry Chemical Extinguishing Systems 904.6, 904.11
*17A-09 Wet Chemical Extinguishing Systems 904.5, 904.11
*30-08 Flammable and Combustible Liquids Code 415.3
*31-06 Installation of Oil-burning Equipment 2113.15
*32-07 Dry Cleaning Plants 415.6.4
*40-07 Storage and Handling of Cellulose Nitrate Film 409.1
*61-08 Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities 415.6.1
*70-08 National Electric Code 603.1.3, 904.3.1, 907.5, 909.11, 909.12.1,  909.16.3, 1205.4.1, 2701.1, 2701.1
*72-07 National Fire Alarm Code 901.6, 903.4.1, 904.3.5, 907.2, 907.2.1.1, 907.2.2.1, 907.2.7.2,  907.2.9.1.3.1, 907.2.10, 907.2.10.4, 907.2.11.2, 907.2.11.3,   907.2.12.2.3, 907.2.12.3, 907.4, 907.5, 907.9.2, 907.10,  907.14, 907.16, 907.17, 911.1, 3006.5
*80-07 Fire Doors and Fire Windows 508.2.2.1, 715.4, 715.4.5, 715.4.6.1, 715.4.7.2, 715.5, 715.5.4, 1008.1.3.3
*85-07 Boiler and Combustion System Hazards Code
(Note: NFPA 8503 has been incorporated into NFPA 85)
415.6.1
*92B-05 Smoke Management Systems in Malls, Atria and Large Spaces 909.8
*101-06 Life Safety Code 1025.6.2
*105-03 Standard for the Installation of Smoke Door Assemblies 405.4.2, 715.4.3.1, 909.20.4.1
*110-05 Emergency and Standby Power Systems 2702.1
*111-05 Stored Electrical Energy Emergency and Standby Power Systems 2702.1
*120-04 Standard for Fire Prevention and Control in Coal Mines 415.6.1
*211-06 Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 2112.5
*230-03 Standard for the Fire Protection of Storage 507.3
*252-03 Standard Methods of Fire Tests of Door Assemblies 715.3, 715.4.1, 715.4.2, 715.4.3, 715.4.4.1
*253-00 Test for Critical Radiant Flux of Floor Covering Systems Using a
Radiant Heat Energy Source
402.11.1, 406.6.4, 804.2, 804.3
*257-00 Standard for Fire Test for Window and Glass Block Assemblies 715.3, 715.4.3.2, 715.5,  715.5.1, 715.5.2, 715.5.8.1
*259-03 Test Method for Potential Heat of Building Materials 2603.4.1.10, 2603.5.3
*265-07 Method of Fire Tests for Evaluating Room Fire Growth Contribution of
Textile Wall Coverings on Full Height Panels and Walls
803.6.2, 803.6.2.1
*268-01 Standard Test Method for Determining Ignitibility of Exterior Wall
Assemblies Using a Radiant Heat Energy Source
1406.2.1, 1406.2.1.1, 1406.2.1.2, 2603.5.7
*285-98 Standard Method of Test for the Evaluation of Flammability Characteristics
of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components
1407.10.4, 2603.5.5
*286-06 Standard Method of Fire Test for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth
402.15.4, 803.2, 803.2.1, 803.5, 803.6.3, 2603.4, 2603.9
*288-01 Standard Methods of Fire Tests of Floor Fire Door Assemblies in Fire-resistance-rated
Floor Systems
711.8
*303-06 Fire Protection Standards for Marinas and Boatyards 905.3.7
*409-04 Aircraft Hangars 412.2.6, 412.4.5
*418-01 Standard for Heliports 412.5.5
*484-06 Combustible Metals, Metal Powders and Metal Dust 415.6.1
*651-98 Machining and Finishing of Aluminum and the Production and Handling of Aluminum Products 415.6.1
*654-06 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing,
Processing and Handling of Combustible Particulate Solids
415.6.1
*655-07 Prevention of Sulfur Fires and Explosions 415.6.1
*664-07 Prevention of Fires Explosions in Wood Processing and Woodworking Facilities 415.6.1
*701-04 Standard Methods of Fire Tests for Flame-propagation of
Textiles and Films
402.11.1, 410.3.6, 801.1.2, 806.1, 806.1.2, 806.2,  3102.3, 3102.3.1, 3102.6.1.1, 3105.4
*704-07 Standard System for the Identification of the Hazards of Materials for Emergency Response 414.7.2, 415.2
*750-06 Water Mist Fire Protection Systems 904.12
*1124-06 Code for the Manufacture, Transportation, Storage and Retail Sale of
Fireworks and Pyrotechnic Articles
415.3.1
*2001-08 Clean Agent Fire Extinguishing Systems 904.10

 

PCI Precast Prestressed Concrete Institute
209W. Jackson Boulevard, Suite 500
Chicago, IL 60606-6938
Standard
reference
number
Title Referenced
in code
section number
MNL 124-89 Design for Fire Resistance of Precast Prestressed Concrete 721.2.3.1
*MNL 128-01 Recommended Practice for Glass Fiber Reinforced Concrete Panels 1903.2

 

PTI Post-Tensioning Institute
1717 W. Northern Avenue, Suite 114
Phoenix, AZ 85021
Standard
reference
number
Title Referenced
in code
section number
PTI-2004 Standard Requirements for Analysis of Shallow Concrete Foundations on Expansive Soils, First Edition 1805.8.2
PTI-2004 Standard Requirements for Design of Shallow Post-tensioned Concrete Foundation on Expansive Soils 1805.8.2

 

RMI Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte, NC 28217
Standard
reference
number
Title Referenced
in code
section number
RMI (2002) Specification for Design, Testing and Utilization of Industrial Steel Storage Racks 2208.1

 

SJI Steel Joist Institute
3127 10th Avenue, North
Myrtle Beach, SC 29577-6760
Standard
reference
number
Title Referenced
in code
section number
JG-1.1-05 Standard Specification for Joist Girders 1604.3.3, 2206.1
K-1.1-05 Standard Specification for Open Web Steel Joists, K-Series 1604.3.3, 2206.1
LH/DLH-1.1-05 Standard Specification for Longspan Steel Joists, LH Series and Deep
Longspan Steel Joists, DLH Series
1604.3.3, 2206.1

 

SPRI Single-Ply Roofing Institute
77 Rumford Ave.
Suite 3-B
Walthem, MA 02453
Standard
reference
number
Title Referenced
in code
section number
*ES-1-03 Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems 1504.5
*RP-4-02 Wind Design Guide for Ballasted Single-ply Roofing Systems 1504.4

 

TIA Telecommunications Industry Association
2500 Wilson Boulevard
Arlington, VA 22201-3834
Standard
reference
number
Title Referenced
in code
section number
TIA/EIA-222-F-96 Structural Standards for Steel Antenna Towers and Antenna Supporting Structures 1609.1.1, 3108.4

 

TMS The Masonry Society
3970 Broadway, Unit 201-D
Boulder, CO 80304-1135
Standard
reference
number
Title Referenced
in code
section number
0216-97 Standard Method for Determining Fire Resistance of Concrete and
Masonry Construction Assemblies
Table 720.1(2), 721.1
*402-05 Building Code Requirements for Masonry Structures 1405.5, 1405.5.2, 1405.9, 1604.3.4, 1704.5, 1704.5.1,  Table 1704.5.1, 1704.5.2, 1704.5.3, Table 1703.4.5.3, 1708.1.1,  1708.1.2, 1708.1.3, 1708.1.4, 1805.5.2, 1812.7, 2101.2.2, 2101.2.3,  2101.2.4, 2101.2.5, 2101.2.6, 2103.13.6, 2106.1, 2106.1.1, 2106.1.1.1,  2106.1.1.2, 2106.1.1.3, 2106.3, 2106.4, 2106.5, 2106.6, 2107.1, 2107.2, 2107.3,  2107.4, 2107.5, 2107.6, 2107.7, 2107.8, 2108.1, 2108.2, 2108.3, 2108.4, 2109.1, 2109.2.3.1, 2109.7.3
*602-05 Specification for Masonry Structures 1405.5.1, Table 1704.5.1, Table 1704.5.3,  1805.5.2.2, 2103.13.7, 2104.1, 2104.1.1, 2104.3, 2104.4

 

TPI Truss Plate Institute
583 D'Onofrio Drive, Suite 200
Madison, WI 53719
Standard
reference
number
Title Referenced
in code
section number
*TPI 1-2002 National Design Standards for Metal-plate-connected Wood Truss Construction 2303.4.2, 2306.1

 

UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
Title Referenced
in code
section number
10A-98 Tin Clad Fire Doors-with Revisions through March 2003 715.4
10B-97 Fire Tests of Door Assemblies-with Revisions through October 2001 715.4.2
10C-98 Positive Pressure Fire Tests of Door Assemblies-with Revisions through November 2001 715.4.1, 715.4.3
14B-98 Sliding Hardware for Standard Horizontally Mounted Tin Clad Fire Doors- with Revisions through July 2000 715.4
14C-99 Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs 715.4
94-96 Test for Flammability of Plastic Materials for Parts in Devices and Appliances 402.11.1
103-01 Factory-built Chimneys, for Residential Type and Building Heating Appliances
717.2.5
127-99 Factory-built Fireplaces-with Revisions through November 1999 717.2.5, 2111.11
199E-04 Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers 904.11.4.1
217-97 Single and Multiple Station Smoke Alarms-with revisions through January 2004 907.2.10
268-96 Smoke Detectors for Fire Protective Signaling Systems-with Revisions through January 1999 407.6, 907.2.6.2
300-96 Fire Testing of Fire Extinguishing Systems for Protection of Restaurant  Cooking Areas - with Revisions through December 1998 904.11
555-99 Fire Dampers-with Revisions through January 2002 716.3
555C-96 Ceiling Dampers 716.3, 716.6.2.1
555S-99 Smoke Dampers-with Revisions through January 2002 716.3, 716.3.1.1
580-94 Test for Uplift Resistance of Roof Assemblies-with Revisions through February 1998 1504.3.1, 1504.3.2
641-95 Type L Low-temperature Venting Systems-with Revisions through April 1999 2113.11.1.4
710B-04 Recirculating Systems 904.11
790-04 Tests for Fire Resistance of Roof Covering Materials-with Revisions through July 1998 1505.1, 2603.6, 2610.2, 2610.3
793-03 Standards for Automatically Operated Roof Vents for Smoke and Heat 910.3.1
864-03 Standards For Control Units and Accessories for Fire Alarm Signaling Systems- with Revisions through October 2003 909.12
*1040-96 Fire Test of Insulated Wall Construction-with Revisions through April 2001 1407.10.3, 2603.4, 2603.9
1256-02 Fire Test of Roof Deck Construction 1508.1, 2603.3, 2603.4.1.5
*1479-03 Fire Tests of Through-penetration Fire stops—with Revisions through August 2008 712.3.1.2, 712.4.1.1.2, 712.5
1482-98 Solid-fuel Type Room Heater-with Revisions through January 2000 2112.2, 2112.5
1715-97 Fire Test of Interior Finish Material
—with Revisions through October 2002
1407.10.2, 1407.10.3, 2603.4, 2603.9
1777-04 Chimney Liners-with Revisions through July 1998 2113.11.1, 2113.19
1784-95 Air Leakage Tests of Door Assemblies 707.14.1, 710.5.2, 715.4.3.1, 715.4.5.1, 715.4.5.3
1897-98 Uplift Tests for Roof Covering Systems-with Revisions through November 2002 1504.3.1
1975-96 Fire Test of Foamed Plastics Used for Decorative Purposes 402.10, 402.11.1, 402.15.5
2017-2000 Standards for General-purpose Signaling Devices and Systems-with Revisions through June 2004 3109.4.1.8
2079-98 Tests for Fire Resistance of Building Joint Systems 702.1, 713.3, 713.6
2200-98 Stationary Engine Generator Assemblies(Revisions through July 2004) 2702.1.1
2390-04 Test Method for Measuring the Wind Uplift Coefficients for Asphalt Shingles 1504.2.1, 1609.5.2

 

ULC Underwriters Laboratories of Canada
7 Crouse Road
Scarborough, Ontario, Canada M1R3A9
Standard
reference
number
Title Referenced
in code
section number
CAN/ULC S102.2-1988 Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings and Miscellaneous Materials and Assemblies with 2000 Revisions 719.4

 

USC United States Code
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
18 USC Part 1, Ch.40 Importation, Manufacture, Distribution and Storage of Explosive Materials 307.2

 

WDMA Window and Door Manufacturers Association
410 N. Michigan Avenue, Suite 2200
Chicago, IL 60611
Standard
reference
number
Title Referenced
in code
section number
*AAMA/WDMA/CSA Specifications for Windows, Doors and Unit Skylights 1714.5.1, 2405.5
101/I.S.2/A440-08

 

WRI Wire Reinforcement Institute, Inc.
203 Loudon Street, S.W.
2nd Floor, Suite 203C
Leesburg, VA 22075
Standard
reference
number
Title Referenced
in code
section number
WRI/CRSI-81 Design of Slab-on-ground Foundations-with 1996 Update 1805.8.2