ACCA
ANSI/ASHRAE/ACCA 183—2007 (reaffirmed 2014)
Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings
AHRI
AMCA
ANSI/AMCA 210—ANSI/ASHRAE 51—07
Laboratory Methods of Testing Fans for Aerodynamic Performance Rating
ANSI
ASHRAE
ANSI/AMCA 210—ANSI/ASHRAE 51—07
Laboratory Methods of Testing Fans for Aerodynamic Performance Rating
180—2012
Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems
102.3
ASME
B16.24—2016
Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900, 1500 and 2500
ASSE
ASSE
1017—2010
Performance Requirements for Temperature Actuated Mixing Values for Hot Water Distribution Systems
ASTM
A53/A53M—12
Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated, Welded and Seamless
Table 1202.4, Table 1202.5, Table 1302.3
A106/A106M—14
Specification for Seamless Carbon Steel Pipe for High-temperature Service
Table 1302.3, Table 1202.5, Table 1202.4, Table 1302.3
A234/A234M—15
Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service
A395/A395M—99(2014)
Standard Specification for Ferritic Ductile Iron Pressure-retaining Castings for Use at Elevated Temperatures
Table 1202.5, Table 1302.3
A420/A420M—14
Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Low-temperature Service
B42—15a
Specification for Seamless Copper Pipe, Standard Sizes
513.13.1, 1107.5.2, Table 1202.4, Table 1302.3
B43—15
Specification for Seamless Red Brass Pipe, Standard Sizes
513.13.1, 1107.5.2, Table 1202.4, Table 1302.3
B251—10
Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube
B280—13
Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service
B813—10
Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube
B828—02(2010)
Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings
D1527—99(2005)
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80
D1785—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120
Table 1202.4, Table 1210.4
D2241—15
Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)
Table 1202.4, Table 1210.4
D2282—99(2005)
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)
D2464—15
Standard Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
D2466—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40
Table 1202.5, Table 1210.5
D2467—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
Table 1202.5, Table 1210.5
D2683—14
Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing
Table 1210.5, 1210.6.6.1
D2846/D2846M—14
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-water Distribution Systems
Table 1202.4, 1203.3.4, Table 1210.4
D2996—01(2007)e01
Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe
D3035—15
Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter
D3261—12e1
Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing
Table 1210.5, 1210.6.6.1
D3309—96a(2002)
Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution Systems
F437—15
Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F438—15
Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40
Table 1202.5, Table 1210.5
F439—13
Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
Table 1202.5, Table 1210.5
F441/F441M—15
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80
Table 1202.4, Table 1210.4
F442/F442M—13e1
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)
Table 1202.4, Table 1210.4
F714—13
Standard Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter
F877—11a
Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution Systems
Table 1202.4, Table 1202.5, Table 1210.4
F1055—13
Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Cross linked Polyethylene (PEX) Pipe and Tubing
Table 1210.5, 1210.6.6.2
F1281—11
Specification for Cross-linked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe
F1282—10
Standard Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe
Table 1202.4, Table 1210.4, Table 1210.5
F1476—07(2013)
Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications
Table 1202.5, 1203.3.7
F1548—01(2012)
Standard Specification for the Performance of Fittings for Use with Gasketed Mechanical Couplings Used in Piping Applications
F1807—15
Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polethylene of Raised Temperature (PE-RT) Tubing
Table 1202.5, Table 1210.5
F1960—15
Specification for Cold-expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing
F1974—09(2005)
Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Poly ethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe
F2080—15
Specification for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe
F2098—08
Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings
F2159—14
Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
Table 1202.5, Table 1210.5
F2389—15
Specification for Pressure-rated Polypropylene Piping Systems
Table 1202.4, Table 1202.5, 1203.15.1, Table 1210.4, Table 1210.5, 1210.6.7.1
F2623—14
Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR9 Tubing
Table 1202.4, Table 1210.4
F2735—09
Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing
F2769—14
Polyethylene of Raised Temperature (PE-RT) Plastic Hot- and Cold-water Tubing and Distribution Systems
Table 1202.4, Table 1210.5
F2806—10(2015)
Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (Metric SDR-PR)
AWS
AWWA
C115/A21.15—11
Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded Flanges
CPSC
CSA
B137.2—16
Polyvinylchloride (PVC) Injection-moulded Gasketed Fittings for Pressure Applications
B137.9—16
Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-pipe Systems
Table 1202.4, Table 1210.4, Table 1210.5
B137.10—16
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Composite Pressure-pipe Systems
CSA B137.1—16
Polyethylene (PE) Pipe, Tubing and Fittings for Cold-water Pressure Services
Table 1210.4, Table 1210.5
CSA B137.5—16
Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications
Table 1210.4, Table 1210.5
CSA B137.11—16
Polypropylene (PP-R) Pipe and Fittings for Pressure Applications
Table 1210.4, Table 1210.5
CSA B137.18—13
Polyethylene of Raised Temperature Resistance (PE-RT) Tubing Systems for Pressure Applications
Table 1202.4, Table 1202.5, Table 1210.5
DOL
FDA
FDA Title 21
Code of Federal Regulations, Title 21, Food and Drugs, Chapter 1, Food and Drug Administration, Parts 174—186 (revised as of April 1, 2015)
FS
WW-P-325B (1976)
Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and Waste Applications)
*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325
ICC
IBC—18
201.3, 202, 301.15, 301.16, 301.17, 301.18, 302.1, 302.2, 304.8, 304.11, 308.4.2.2, 308.4.2.4, 401.4, 401.5, 406.1, 501.3.1, 501.3.2, 502.10, 502.10.1, 504.2, 504.10, 505.3, 506.3.3, 506.3.10, 506.4.1, 509.1, 510.6, 510.6.3, 510.6.2, 510.7, 510.7.1.1, 510.7.2, 510.7.3, 510.8, 511.1.5, 513.1, 513.2, 513.3, 513.4.3, 513.5, 513.5.2, 513.5.3, 513.5.3.2, 513.6.2, 513.10.5, 513.11.1, 513.12, 513.12.2, 601.3, 602.2, 602.3, 602.4, 603.1, 603.10, 603.13, 603.18.2, 607.1.1, 607.1.2, 607.3.2.1, 607.5.1, 607.5.2, 607.5.3, 607.5.4, 607.5.4.1, 607.5.5, 607.5.5.1, 607.5.6, 607.6, 607.6.1, 607.6.2, 607.6.2.1, 607.6.3, 701.2, 801.3, 801.16.1, 801.18.4, 801.18.4.1, 902.1, 908.3, 908.4, 910.3, 924.1, 925.1, 926.1, 927.2, 928.1, 1004.6, 1105.1, 1206.4, 1210.8.2, 1305.2.1, 1402.4, 1402.4.1
IFC—18
International Fire Code®
201.3, 310.1, 311.1, 502.4, 502.5, 502.7.2, 502.8.1, 502.9.1, 502.9.5, 502.9.5.2, 502.9.5.3, 502.9.8.2, 502.9.8.3, 502.9.8.5, 502.9.8.6, 502.9.11, 502.10, 502.10.3, 502.16.2, 509.1, 510.2.1, 510.2.2, 510.5, 511.1.1, 513.1, 513.2, 513.6.3, 513.12.1, 513.12.3, 513.12.4, 513.15, 513.16, 513.17, 513.18, 513.19, 606.2.1, 606.4.1, 908.7, 924.1, 926.1, 1101.9, 1105.3, 1105.9, 1106.5, 1106.6, 1301.1, 1301.2, 1301.5
ICC 900/SRCC Standard 300—15
Solar Thermal System Standard
1002.1, 1401.4, 1401.4.1, 1402.1, 1402.3.1, 1402.4, 1402.8.1.1, 1402.8.1.4, 1402.8.5, 1402.8.5.3, 1403.2
IIAR
MSS
NAIMA
NBBI
NFPA
37—18
Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines
91—15
Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists and Noncombustible Particulate Solids
262—15
Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-handling Spaces
286—15
Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
704—17
Standard System for Identification of the Hazards of Materials for Emergency Response
NSF
NSF 358-1—2014
Polyethylene Pipe and Fittings for Water-based Ground-source "Geothermal" Heat Pump Systems
Table 1210.4, Table 1210.5
NSF 358-2—2012
Polypropylene Pipe and Fittings for Water-based Ground-source "Geothermal" Heat Pump Systems
Table 1210.4, Table 1210.5
SMACNA
SMACNA/ANSI—2016
HVAC Duct Construction Standards-Metal and Flexible 4th Edition (ANSI) 2016
603.4, Table 603.4, 603.9, 603.10
UL
17—2008
Vent or Chimney Connector Dampers for Oil-fired Appliances—with revisions through September 2013
103—2010
Factory-built Chimneys, Residential Type and Building Heating Appliance—with revisions through July 2012
207—2009
Refrigerant-containing Components and Accessories, Nonelectrical—with revisions through June 2014
391—2010
Solid-fuel and Combination-fuel Central and Supplementary Furnaces—with revisions through June 2014
762—2010
Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances—with revisions through October 2013
1453—04
Electric Booster and Commercial Storage Tank Water Heaters—with revisions through July 2011
1479—03
Fire Tests of Through-penetration Firestops—with revisions through June 2015
2024—2011
Standard for Safety Optical-fiber and Communications Cable Raceway—with revisions through August 2015
2043—2008
Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-handling Spaces—with revisions through October 2013
2523—09
Solid Fuel-fired Hydronic Heating Appliances—with revisions through February 2013