Heads up:
There are no suggested sections in this chapter.
Heads up:
There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.7.
AASHTO | American Association of State Highway and Transportation Officials 444 North Capitol Street, Northwest, #249 Washington, DC 20001 | |
Standard reference number | Title | Referenced in code section number |
HB-17—2002 | Specification for Highway Bridges, 17th Edition 2002 | 503.2.6 |
AFSI | Architectural Fabric Structures Institute c/o Industrial Fabric Association International 1801 County Road B West Roseville, MN 55113 | |
Standard reference number | Title | Referenced in code section number |
ASI—77 | Design and Standard Manual | 3103.10.2 |
ANSI | American National Standards Institute 25 West 43rd Street, Fourth Floor New York, NY 10036 | |
Standard reference number | Title | Referenced in code section number |
ANSI E1.21—2006 | Entertainment Technology: Temporary Ground Supported Overhead Structures Used to Cover the Stage Areas and Support Equipment in the Production of Outdoor Entertainment Events | 3105.1 |
ANSI Z21.69/ CSA 6.16—09 | Connectors for Movable Gas Appliances | 609.4 |
API | American Petroleum Institute 1220 L Street, Northwest Washington, DC 20005 | |
Standard reference number | Title | Referenced in code section number |
Spec 12P—3rd Edition (Reaffirmed 2008) | Specification for Fiberglass Reinforced Plastic Tanks | 5704.2.13.1.5 |
RP 651 3rdEdition (2007) | Cathodic Protection of Aboveground Petroleum Storage Tanks | 5706.7, 5706.7.1 |
Std 653—4thEdition (2009) | Tank Inspection, Repair, Alteration and Reconstruction | 5706.7, 5706.7.1 |
RP 752—3rdEdition (2009) | Management of Hazards Associated with Location of Process Plant Buildings, CMA Managers Guide | 5706.7 |
RP 1604—3rdEdition (1996 R2010) | Closure of Underground Petroleum Storage Tanks | 5704.2.13 |
RP 1615—(1996) 6thEdition (2011) | Installation of Underground-petroleum Storage Systems | 5704.2.13.1.5, 5706.7 |
Std 2000—6thEdition (2009) | Venting Atmosphere and Low-pressure Storage Tanks: Nonrefrigerated and Refrigerated | 5704.2.7.3.2 |
RP 2001—9thEdition (2012) | Fire Protection in Refineries, 8th Edition | 5706.7 |
RP 2003— 7thEdition(2008) | Protection Against Ignitions Arising out of Static, Lightning and Stray Currents | 5706.7 |
Publ 2009 7thEdition— (2002, R2012) | Safe Welding and Cutting Practices in Refineries, Gas Plants and Petrochemical Plants | 5706.7 |
Std 20151—6thEdition 2001 (R2006) | Safe Entry and Clearing of Petroleum Storage Tanks | 5706.7, 5706.7.2 |
RP 2023 3rdEdition— (2001, R2006) | Guide for Safe Storage and Handling of Heated Petroleum-derived Asphalt Products and Crude-oil Residue | 5706.7, 5706.7.3 |
Publ 2028 3rdEdition— (2002, R2012) | Flame Arrestors in Piping Systems | 5704.2.7.3.2 |
Publ 2201 5thEdition— (2003, R2010) | Procedures for Welding or Hot Tapping on Equipment in Service | 5706.7 |
RP 2350 4thEdition— (2012) | Overfill Protection for Storage Tanks in Petroleum Facilities, 3rd Edition | 5704.2.7.5.8, 5706.4.6, 5706.7 |
ASCE/SEI | American Society of Civil Engineers Structural Engineering Institute 1801 Alexander Bell Drive Reston, VA 20191 | |
Standard reference number | Title | Referenced in code section number |
ASCE/SEI 24—13 | Flood Resistant Design and Construction | 604.1.7 |
ASHRAE | American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1791 Tullie Circle, NE Atlanta, GA 30329 | |
Standard reference number | Title | Referenced in code section number |
15—2013 | Safety Standard for Refrigeration Systems | 606.12.1 |
ASME | The American Society of Mechanical Engineers Two Park Avenue New York, NY 10016-5990 | |
Standard reference number | Title | Referenced in code section number |
A13.1—2007 | Scheme for the Identification of Piping Systems | 3509.3, 5003.2.2.1, 5303.4.3, 5503.4.5, 5703.5.2 |
ASME A17.1/CS B44—2013 | Safety Code for Elevators and Escalators | 508.1.6, 607.1, 907.3.3, 1009.4 |
A17.3—2008 | Safety Code for Existing Elevators and Escalators | 1103.3.1, 1103.3.2 |
B16.18—2012 | Cast Copper-Alloy Solder Joint Pressure Fittings | 909.13.1 |
B16.22—2001 (R2010) | Wrought Copper and Copper-Alloy Solder-joint Pressure Fittings | 909.13.1 |
B31.1—2012 | Power Piping | 5003.2.2, Table 5703.6.2 |
B31.3—2012 | Process Piping | 5003.2.2.2, Table 5703.6.2 |
B31.4—2012 | Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids | Table 5703.6.2 |
B31.9—B31.9 | Building Services Piping | Table 5703.6.2, 5703.6.3, 5703.6.11 |
BPVC—2010/2011 addenda | ASME Boiler and Pressure Vessel Code (Sections I, II, IV, V & VI, VIII) | 5003.2.1, 5303.2, 5303.3.2, 5503.2.6, 5503.4.3, 5503.7, 5704.2.13.1.5, 5806.3.1, 5806.4.1, 5806.4.8 |
ASSE | American Society of Safety Engineers 1800 East Oakton Street Des Plaines, IL 60018 | |
Standard reference number | Title | Referenced in code section number |
ANSI/ASSE Z359.1-2007 | Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components, Part of the Fall Protection Code | 1015.6, 1015.7 |
ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 | |
Standard reference number | Title | Referenced in code section number |
B 42—10 | Specification for Seamless Copper Pipe, Standard Sizes | 909.13.1 |
B 43—09 | Specification for Seamless Red Brass Pipe, Standard Sizes | 909.13.1 |
B 68—11 | Specification for Seamless Copper Tube, Bright Annealed | 909.13.1 |
B 88—09 | Specification for Seamless Copper Water Tube | 909.13.1 |
B 251—10 | Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube | 909.13.1 |
B 280—08 | Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service | 909.13.1 |
D 56—05(2010) | Test Method for Flash Point by Tag Closed Tester | 202 |
D 86—2012 | Test Method for Distillation of Petroleum Products at Atmospheric Pressure | 202 |
D 92—12b | Test Method for Flash and Fire Points by Cleveland Open Cup | 202, 2401.2, 5104.1.1, 5701.2 |
D 93—12 | Test Method for Flash Point by Pensky-Martens Closed Up Tester | 202 |
D 323—08 | Test Method for Vapor Pressure of Petroleum Products (Reid Method) | 202 |
D 2859—06(2011) | Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials | 804.3.3.1, 804.3.3.2 |
D 3278—96(2011) | Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus | 202 |
E 84—2013A | Test Method for Surface Burning Characteristics of Building Materials | 202, 803.1, 803.1.1, 803.1.2, 803.5.1, 803.5.2, 803.6, 803.7, 803.10, 804.1, 804.1.1, 804.2.4 |
E 108—2011 | Test Methods for Fire Tests of Roof Coverings | 317.3 |
E 681—2009 | Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases) | 202 |
E 1354—2013 | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter | 304.3.2, 304.3.4, 318.1, 808.1, 808.2, 2310.5.3, 3304.2.3, 3603.4 |
E 1529—13 | Test Method for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies | 5704.2.9.2.3 |
E 1537—13 | Test Method for Fire Testing of Upholstered Furniture | 805.1.1.2, 805.2.1.2, 805.3.1.2, 805.4.1.2 |
E 1590—13 | Test Method for Fire Testing of Mattresses | 805.1.2.2, 805.2.2.2, 805.3.2.2.1, 805.4.2.2 |
E 1966—2012A | Test Method for Fire-resistant Joint Systems | 202 |
E 2072—10 | Standard Specification for Pholuminescent (Phosphorescent) Safety Markings | 1025.4 |
E 2404—2013E1 | Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics | 803.5.2, 803.6, 803.7 |
E 2573—12 | Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics | 803.10 |
F 1085—10 | Standard Specification for Mattress and Box Springs for Use in Berths in Marine Vessels | 5706.7, 5706.7.2805.3.2.2.2 |
F 2006—10 | Standard/Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows | 1015.8 |
F 2090—10 | Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms | 1015.8, 1015.8.1 |
F 2200—13 | Standard Specification for Automated Vehicular Gate Construction | 503.5, 503.6 |
BHMA | Builders Hardware Manufacturers' Association 355 Lexington Avenue, 15th Floor New York, NY 10017 | |
Standard reference number | Title | Referenced in code section number |
A156.10—2011 | American National Standard for Power-operated Pedestrian Doors | 1010.1.4.2 |
A156.19—2013 | American National Standard for Power Assist and Low-energy Power-operated Doors | 1010.1.4.2 |
A156.27—2011 | Power and Manual Operated Revolving Pedestrian Doors | 1010.1.4.1, 1010.1.4.3.1 |
CA | State of California Department of Consumer Affairs Bureau of Electronics and Appliance Repair, Home Furnishings and Thermal Insulation 4244 South Market Court, Suite D Sacramento, CA 95834-1243 | |
Standard reference number | Title | Referenced in code section number |
California Technical Bulletin 129—1992 | Flammability Test Procedure for Mattresses for Use in Public Buildings | 805.1.1.2, 805.2.2.2, 805.3.2.2.1, 805.4.2.2 |
California Technical Bulletin 133—1991 | Flammability Test Procedure for Seating Furniture for Use in Public Occupancies | 805.1.1.2, 805.2.1.2, 805.4.1.2 |
CGA | Compressed Gas Association 14501 George Carter Way, Suite 103 Chantilly, VA 20151 | |
Standard reference number | Title | Referenced in code section number |
C-7—(2011) | Guide to the Preparation of Precautionary Labeling and Marking of Compressed Gas Containers | 5303.4.2, 5503.4.2 |
G-13—(2006) B44—2013 | Storage and Handling of Silane and Silane Mixtures (an American National Standard) | 6404.1, 6404.2, 6405.3 |
P-1—(2000) | Safe Handling of Compressed Gases in Containers | 5305.7 |
ANSI/P-18—(2006) | Standard for Bulk Inert Gas Systems | 5501.1 |
S-1.1—(2011) | Relief Device Standards—Part 1—Cylinders for Compressed Gases | 5303.3.2, 5503.2 |
S-1.2—(2005) | Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases | 5303.3.2, 5503.2 |
S-1.3—(2008) | Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases | 5303.3.2, 5503.2 |
V-1—(2005) | Standard for Gas Cylinder Valve Outlet and Inlet Connections | 3505.2.1 |
CGR | Coast Guard Regulations c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 | |
Standard reference number | Title | Referenced in code section number |
46 CFR Parts 30, 32, 35 & 39—1999 | Shipping | 5706.8 |
CPSC | Consumer Product Safety Commission 4330 East West Highway Bethesda, MD 20814 | |
Standard reference number | Title | Referenced in code section number |
16 CFR Part 1500.41—2009 | Method for Testing Primary Irritant Substances | 202 |
16 CFR Part 1500.42—2009 | Test for Eye Irritants | 202 |
16 CFR Part 1500.44—2009 | Method for Testing Extremely Flammable and Flammable Solids | 202 |
16 CFR Part 1500—2009 | Hazardous Substances and Articles; Administration and Enforcement Regulations | 202, 5601.1.3 |
16 CFR Part 1507—2002 | Fireworks Devices | 5601.1.3 |
16 CFR Part 1630—2007 | Standard for the Surface Flammability of Carpets and Rugs | 804.3.3.1, 804.3.3.2 |
DOC | U.S. Department of Commerce 1401 Constitution Avenue, NW Washington, DC 20230 Washington, DC 20402-9325 | |
Standard reference number | Title | Referenced in code section number |
16 CFR Part 1632—2009 | Standard for the Flammability of Mattress and Mattress Pads (FF 4-72, Amended) | 805.1.2.1, 805.2.2.1, 805.3.2.1, 805.4.2.1 |
DOL | U.S. Department of Labor c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 | |
Standard reference number | Title | Referenced in code section number |
29 CFR Part 1910.1000—2009 | Air Contaminants | 202, 2104.2.1 |
29 CFR Part 1910.1200—2009 | Hazard Communication | 202, 5603.6 |
DOTn | U.S. Department of Transportation Office of Hazardous Material Safety 1200 New Jersey Avenue, SE East Building, 2nd Floor Washington, DC 20590 | |
Standard reference number | Title | Referenced in code section number |
33 CFR Part 154—1998 | Facilities Transferring Oil or Hazardous Material in Bulk | 5706.8 |
33 CFR Part 155—1998 | Oil or Hazardous Material Pollution Prevention Regulations for Vessels | 5706.8 |
33 CFR Part 156 —1998 | Oil and Hazardous Material Transfer Operations . | 5706.8 |
49 CFR Parts 100-185— 2005 | Hazardous Materials Regulations | 202, 3505.4, 5303.2, 5503.4.3, 5503.7, 5601.1, 5601.1.3, 5601.3, 5706.5.1.15 |
49 CFR Part 172—2009 | Hazardous Materials Tables, Special Provisions, Hazardous Materials Communications, Emergency Response Information and Training Requirements | 5604.6.5.2 |
49 CFR Part 173—2009 | Shippers—General Requirements for Shipments and Packagings | 5104.1.1, 5606.3 |
49 CFR Part 173.137—2009 | Shippers—General Requirements for Shipments and Packagings: Class 8—Assignment of Packing Group | 202 |
DOTy | U.S. Department of Treasury c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 | |
Standard reference number | Title | Referenced in code section number |
27 CFR Part 55—1998 | Commerce in Explosives, as amended through April 1, 1998 | 202, 5604.6.5.2 |
EN | European Committee for Standardization (EN) Central Secretariat Rue de Stassart 36 B-10 50 Brussels | |
Standard reference number | Title | Referenced in code section number |
European Standard EN 1081 | 1998 Resilient Floor Coverings—Determination of the Electrical Resistance | 2309.5.1.1 |
FCC | Federal Communications Commission Wireless Telecommunications Bureau (WTB) 445 12th Street, SW Washington, DC 20554 | |
Standard reference number | Title | Referenced in code section number |
47 CFR Part 90.219—2007 | Private Land Mobile Radio Services—Use of Signal Boosters | 510.5.4 |
FM | Factory Mutual Global Research Standards Laboratories Department 1301 Atwood Avenue, P.O. Box 7500 Johnston, RI 02919 Washington, DC 20554 | |
Standard reference number | Title | Referenced in code section number |
4430—12 | Approval Standard for Heat and Smoke Vents | 910.3.1 |
ANSI/FM 4996—13 | Approval Standard for Classification of Pallets and Other Material Handling Products as Equivalent to Wood Pallets | 3206.4.1.1 |
ICC | International Code Council, Inc. 500 New Jersey Avenue, NW 6th Floor Washington, DC 20001 | |
Standard reference number | Title | Referenced in code section number |
ICC A117.1—09 | Accessible and Usable Buildings and Facilities | 907.5.2.3.3, 1009.9, 1009.11, 1010.14.9.7, 1012.1, 1012.6.5, 1012.10, 1013.4, 1023.9 |
ICC 300—12 | Standard on Bleachers, Folding and Telescopic Seating and Grandstands | 1029.1.1, 1029.16 |
IBC—15 | International Building Code® | 102.3, 102.4, 201.3, 202, 304.1.3, 306.1, 311.1.1, 311.3, 313.1, 317.1, 403.8.2, 403.11.4, 404.2.1, 504.1, 508.1, 508.1.2, 603.2, 603.5.2, 603.6.1, 603.8, 604.1.2, 604.1.7, 604.2.2, 604.2.6, 604.2.7, 604.2.9, 604.2.13, 604.2.16, 605.11, 607.3, 607.4, 607.5, 607.6, 608.4, 608.8, 701.1, 704.1, 801.1, 803.1, Table 803.3, 803.7.2, 803.8.1, 803.8.2, 807.3, 807.5.1.2, 808.1, 808.2, 901.4.1, 901.4.2, 901.4.3, 901.8.2, 903.2, 903.2.5.2, 903.2.8.3.2, 903.2.9.1, 903.2.10, 903.3.1.1.1, 903.3.1.2, 903.3.2, 904.13, 907.1.1, 907.2.1, 907.2.1.9, 907.2.6.2, 907.2.6.3.3, 907.2.7, 907.2.13, 907.2.18, 907.2.21, 907.5.2.1, 907.5.2.2.4, 907.6.6, 909.1, 909.2, 909.3, 909.4.3, 909.5, 909.5.3, 909.5.3.1, 909.5.3.2, 909.6.3, 909.10.5, 909.11.1, 909.18.8, 909.21.1, 910.4.5, Table 911.1, 911.2, 914.1, 914.2.1, 914.3.1, 914.3.2, 914.4.1, 914.5.3, Table 914.8.3, 914.8.3.2, 914.10, 915.1.6, 1003.2, 1003.5, Table 1004.1.2, 1004.4, 1005.7.2, 1006.2.1, 1009.2, 1009.4, 1009.5, 1009.6.4, 1010.1.4.1, 1010.1.4.3, 1010.1.5, 1010.1.7, 1010.1.9.1, 1010.1.9.11, 1011.10, 1011.11, 1011.12.2, 1012.6.3, 1012.6.4, 1014.1, 1015.2, 1015.2.1, 1016.2, 1018.3, 1018.5, 1019.3, 1019.4,1020.1, Table 1020.1, 1021.4, 1023.2, 1023.3.1, 1023.4, 1023.5, 1023.6, 1023.7, 1023.11.1, 1023.11.2, 1024.3, 1024.4, 1024.5, 1024.6, 1024.7, 1026.2, 1026.3, 1027.5, 1028.1.6, 1029.1.1.1, 1101.2, 1101.3, 1103.1, 1103.3.2, 1103.4.1, 1103.4.8, 1103.4.9.1, 1103.4.9.2.1, 1103.4.9.2.2, 1103.4.9.4, 1103.4.9.5, 1103.4.10, 1104.5, 1104.17, 1104.17.1, Table 1104.17.2, 1105.3.1, 1105.3.3.1, 1105.3.3.2, 1105.4.7, 1105.6.2, 1105.6.3, 1105.6.4, 1105.6.5, 1105.6.6, 1105.6.7, 1105.7, 2004.6, 2006.17, 2007.1, 2007.4, 2103.3, 2107.1, 2301.1, 2301.4, 2303.1, 2307.4, 2308.3, 2308.3.1, 2308.3.1.2, 2309.3.1.5.1, 2309.3.2, 2309.6.1.2.3, 2310.1, 2311.1, 2311.3.1, 2311.4.1, 2404.2, 2404.3.1, 2404.3.2.6, 2404.3.3, 2405.2, 2701.1, 2701.4, 2703.2.2, 2703.3.1, 2703.3.2, 2703.3.3, 2703.3.4, 2703.3.8, 2703.14, 2703.14.1, 2703.14.2, 2703.15.1, 2704.3.1, 2705.2.3.2, 2705.3.1, 2705.3.2.1, 2705.3.3, 2803.1, 2905.1, 2909.2, 2909.4, 2909.6, 3101.1, 3103.1, 3103.8.2, 3103.8.4, 3103.9.1, 3104.1, 3105.5, 3314.1, 3403.1, 3704.3, 3704.4, 3704.5, 5003.2.2.2, 5003.2.8, 5003.8.1, Table 5003.8.2, 5003.8.3.1, 5003.8.4.1, 5003.9.9, 5004.13, 5005.2, 5005.3.9, 5101.1, 5303.16.1, 5303.16.2, 5306.2, 5306.2.1, 5503.1.2, 5503.5.2, 5504.2.1.2, 5504.2.2.2, 5505.4.1, 5604.2, Table 5604.5.2(3), 5605.5, 5701.3, 5704.2.7.7, 5704.2.8.1, 5704.2.8.2, 5704.2.9.3, 5704.2.9.4, 5704.3.3.5, 5704.3.7.1, 5704.3.8, 5705.3.4, 5705.3.5.3, 5705.3.7.1, 5705.3.7.2, 5705.3.7.3, 5705.3.7.4, 5705.3.7.5.1, 5706.2.3, 5706.4.1, 5803.1.1, 5806.4.3, 5808.1, 5808.3, 5808.3.2, 5906.2.2, 5906.2.3, 5906.4.2, 6003.1.4.2, 6005.3.1, 6109.11.2, 6204.1.2, 6306.4, 6404.1.4, 6604.1 |
IEBC—15 | International Existing Building Code® | 1011.5.2, 1103.1 |
IFGC—15 | International Fuel Gas Code® | 201.3, 603.1, 603.1.2, 603.5.2, 603.8, 2301.1, 2301.6, 2309.3.1.2, 2309.3.1.5, 2504.5, 3001.1, 3003.1, 3004.1, 3004.2, 3104.15.1, 3104.15.2, 3104.16.1, 3303.1, 3303.3, 3306.2.1, Table 5003.1.1(1), 5301.1, 5801.1, 5803.1.4, 6103.1, 6103.2.1.7, 6103.3 |
IMC—15 | International Mechanical Code® | 201.3, 202, 308.3, 603.1, 603.1.2, 603.2, 603.3, 603.3.2.4, 603.5.2, 603.8, 606.1, 606.2, 606.3, 606.4, 606.7, 606.8, 606.9, 606.16, 608.6.1, 609.1, 903.2.11.4, 904.12, 907.3.1, 909.1, 909.10.2, 909.13.1, 910.4.7, 1006.2.2.3, 1011.16, 1020.5.1, 2104.2.1, 2105.3, 2301.1, 2301.6, 2309.3.1.2, 2309.3.2.3, 2311.3.1, 2311.4.3, 2311.7.1, 2404.7, 2404.7.2, 2504.5, 2703.2.2, 2703.10.4, 2703.14, 2803.2, 2803.3, 3001.1, 3003.1, 3004.2, 3104.15.1, 3104.15.2, 3303.1, 3703.5, Table 5003.1.1(1), 5003.8.4.2, 5003.8.5.2, 5003.8.6.2, 5004.3.1, 5303.7.6, 5303.16.9, 5305.5, 5306.2.2, 5307.5.1, 5504.2.1.3, 5504.2.2.3, 5505.4.1.1, 5701.3, 5703.6.1, 5704.2.8.9, 5705.3.7.5.1, 5706.2, 5706.4.4, 6003.1.3, 6003.2.3.2, 6004.2.2.7, 6005.3.1, 6005.3.2, 6103.2.1.7 |
IPC—15 | International Plumbing Code® | 201.3, 903.3.5, 904.11.1.3, 912.6, 2311.2.3, 5004.2.2.6 |
IPMC—15 | International Property Maintenance Code® | 311.1.1 |
IRC—15 | International Residential Code® | 102.5, 202, 605.11, 605.11.1.2, 1001.1 |
IWUIC—15 | International Wildland-Urban Interface Code® | 304.1.2 |
IIAR | International Institute of Ammonia Refrigeration 1001 N. Fairfax Street, Suite 503 Alexandria, VA 22314 | |
Standard reference number | Title | Referenced in code section number |
IIAR-2—2014 | Equipment, Design and Installation of Closed-Circuit Ammonia Mechanical Refrigerating Systems | 606.12.1.1 |
IIAR-7—2013 | Developing Operating Procedures for Closed-Circuit Ammonia Mechanical Refrigerating Systems | 606.12.1.1 |
IKECA | International Kitchen Exhaust Cleaning Association 100 North 20th Street, Suite 400 Philadelphia, PA 19103 | |
Standard reference number | Title | Referenced in code section number |
C10—2011 ANSI/IKECA | Standard for Cleaning of Commercial Kitchen Exhaust Systems | 609.3.3.2 |
ISO | International Organization for Standardization (ISO) ISO Central Secretariat 1 ch, de la Voie-Creuse, Case postale 56 CH-1211 Geneva 20, Switzerland | |
Standard reference number | Title | Referenced in code section number |
ISO 8115—86 | Cotton Bales—Dimensions and Density | Table 2704.2.2.1, Table 5003.1.1(1) |
NEMA | National Electrical Manufacturer's Association 1300 N. 17th Street, Suite 1752 Rosslyn, VA 22209 | |
Standard reference number | Title | Referenced in code section number |
250—2003 | Enclosures for Electrical Equipment (1,000 Volt Maximum) | 6005.2 |
NFPA | National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 | |
Standard reference number | Title | Referenced in code section number |
02—11 | Hydrogen Technologies Code | 2309.3.1.1, 2309.3.1.2, 5301.1, 5307.3, 5801.1 |
10—13 | Standard for Portable Fire Extinguishers | Table 901.6.1, 906.2, 906.3, Table 906.3(1), Table 906.3(2), 906.3.2, 906.3.4, 3006.3, I101.1 |
11—10 | Standard for Low-, Medium- and High-expansion Foam | 904.7, 5704.2.9.2.2 |
12—11 | Standard on Carbon Dioxide Extinguishing Systems | Table 901.6.1, 904.8, 904.12 |
12A—09 | Standard on Halon 1301 Fire Extinguishing Systems | Table 901.6.1, 904.9 |
13—13 | Standard for the Installation of Sprinkler Systems | 903.3.1.1, 903.3.2, 903.3.8.2 903.3.8.5, 904.12, 905.3.4, 907.6.4, 914.3.2, 1019.3, 1103.4.8, 3201.1, 3204.2, Table 3206.2, 3206.4.1, 3206.9, 3207.2, 3207.2.1, 3208.2.2, 3208.2.2.1, 3208.4, 3210.1, 3401.1, 5104.1, 5104.1.1, 5106.5.7, 5704.3.3.9, Table 5704.3.6.3(7), 5704.3.7.5.1, 5704.3.8.4 |
13D—13 | Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes | 903.3.1.3 |
13R—13 | Standard for the Installation of Sprinkler Systems in Low Rise Residential Occupancies | 903.3.1.2, 903.3.5.2, 903.4 |
14—13 | Standard for the Installation of Standpipe and Hose Systems | 905.2, 905.3.4, 905.4.2, 905.6.2, 905.8 |
15—12 | Standard for Water Spray Fixed Systems for Fire Protection | 5704.2.9.2.3 |
16—15 | Standard for the Installation of Foam-water Sprinkler and Foam-water Spray Systems | 904.7, 904.12 |
17—13 | Standard for Dry Chemical Extinguishing Systems | Table 901.6.1, 904.6, 904.12 |
17A—13 | Standard for Wet Chemical Extinguishing Systems | Table 901.6.1, 904.5, 904.12 |
20—13 | Standard for the Installation of Stationary Pumps for Fire Protection | 913.1, 913.2, 913.5.1 |
22—13 | Standard for Water Tanks for Private Fire Protection | 507.2.2 |
24—13 | Standard for Installation of Private Fire Service Mains and Their Appurtenances | 507.2.1, 2809.5 |
25—14 | Standard for the Inspection, Testing and Maintenance of Water-based Fire Protection Systems | 507.5.3, Table 901.6.1, 904.7.1, 912.7, 913.5 |
30—12 | Flammable and Combustible Liquids Code | 610.1, 5701.2, 5703.6.2, 5703.6.2.1, 5704.2.7, 5704.2.7.1, 5704.2.7.2, 5704.2.7.3.2, 5704.2.7.4, 5704.2.7.6, 5704.2.7.7, 5704.2.7.8, 5704.2.7.9, 5704.2.9.3, 5704.2.9.4, 5704.2.9.6.1.1, 5704.2.9.6.1.2, 5704.2.9.6.1.3, 5704.2.9.6.1.4, 5704.2.9.6.1.5, 5704.2.9.6.2, 5704.2.9.7.3, 5704.2.10.2, 5704.2.11.3, 5704.2.11.4.2, 5704.2.12.1, 5704.3.1, 5704.3.6, Table 5704.3.6.3(1), Table 5704.3.6.3(2), Table 5704.3.6.3(3), 5704.3.7.2.3, 5704.3.8.4, 5706.8.3 |
30A—15 | Code for Motor Fuel-dispensing Facilities and Repair Garages | 2301.4, 2301.5, 2301.6, 2306.6.3, 2310.1 |
30B—15 | Code for the Manufacture and Storage of Aerosol Products | 5101.1, 5103.1, 5104.1, Table 5104.3.1, Table 5104.3.2, Table 5104.3.2.2, 5104.4.1, 5104.5.2, 5104.6, 5106.2.3 5106.3.2, Table 5106.4,5106.5.1, 5106.5.6, 5107.1 |
31—11 | Standard for the Installation of Oil-burning Equipment | 603.1.7, 603.3.1, 603.3.3 |
32—11 | Standard for Dry Cleaning Plants | 2107.1, 2107.3 |
33—1115 | Standard for Spray Application Using Flammable or Combustible Materials | 2404.3.2 |
34—15 | Standard for Dipping, Coating and Printing Processes Using Flammable or Combustible Liquids | 2405.3, 2405.4.1.1 |
35—11 | Standard for the Manufacture of Organic Coatings | 2901.3, 2905.4 |
40—11 | Standard for the Storage and Handling of Cellulose Nitrate Film | 306.2 |
51—13 | Standard for the Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes | 3501.5, 3507.1, 3509.1 |
51A—12 | Standard for Acetylene Cylinder Charging Plants | 3508.1 |
51B—14 | Fire Prevention During Welding, Cutting and Hot Work | 3503.1 |
52—13 | Vehicular Gaseous Fuel System Code | 5301.1 |
55—13 | Compressed Gases and Cryogenic Fluids Code | 2309.2.1, 5301.1, 5307.3, 5501.1, 5801.1, 6301.1 |
56—12 | Standard for Fire and Explosion Prevention during Cleaning and Purging of Flammable Gas Piping Systems | 3306.2.1 |
58—14 | Liquefied Petroleum Gas Code | 603.4.2.1.1, 6101.1, 6103.1, 6103.2.1, 6103.2.1.2, 6103.2.1.7, 6103.2.2, 6104.1, 6104.3.2, 6104.4, 6105.2, 6106.2, 6106.3, 6107.2, 6107.4, 6108.1, 6108.2, 6109.11.2, 6111.3 |
59A—13 | Standard for the Production, Storage and Handling of Liquefied Natural Gas (LNG) | 5301.1, 5501.1 |
61—13 | Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities | Table 2204.1 |
68—13 | Venting of Deflagrations | 911.1, Table 2204.1 |
69—14 | Standard on Explosion Prevention Systems | 911.1, 911.3, Table 2204.1 |
70—14 | National Electrical Code | 603.1.3, 603.1.7, 603.5.2, 604.1.2, 605.3, 605.4, 605.9, 605.11, 606.16, 610.6, 610.7, 904.3.1, 907.6.1, 909.12.2, 909.16.3, 910.4.6, 2006.3.4, 2104.2.3, 2108.2, Table 2204.1, 2301.5, 2305.4, 2308.8.1.2.4, 2309.2.3, 2309.6.1.2.4, 2311.3.1, 2403.2.1, 2403.2.1.1, 2403.2.1.4, 2403.2.5, 2404.6.1.2.2, 2404.9.4, 2504.5, 2603.2.1, 2606.4, 2703.7.1, 2703.7.2, 2703.7.3, 2803.4, 2904.1, 3103.12.6.1, 3104.15.7, 3304.7, 3506.4, 5003.7.3, 5003.8.7.1, 5003.9.4, 5303.7.6, 5303.8, 5303.16.11, 5303.16.14, 5503.6, 5503.6.2, 5703.1, Table 5703.1.1, 5703.1.3, 5704.2.8.12, 5704.2.8.17, 5706.2.8, 5803.1.5, 5803.1.5.1, 5807.1.10, 5906.5.5, 5906.5.6, 6109.15.1 |
72—13 | National Fire Alarm and Signaling Code | 508.1.6, 604.2.4, Table 901.6.1, 903.4.1, 904.3.5, 907.2, 907.2.6, 907.2.9.3, 907.2.11, 907.2.13.2, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.2.2, 907.5.2.2.5, 907.6, 907.6.1, 907.6.2, 907.6.6, 907.7, 907.7.1, 907.7.2, 907.8, 907.8.2, 907.8.5, 1103.3.2 |
77—14 | Static Electricity | 5003.9.5 |
80—13 | Standard for Fire Doors and Other Opening Protectives | 703.1.3, 1010.1.4.3 |
85—15 | Boiler and Combustion System Hazards Code | Table 2204.1 |
86—15 | Standard for Ovens and Furnaces | 3001.1 |
92—15 | Standard for Smoke Control Systems | 909.7, 909.8Table 901.6.1 |
96—14 | Ventilation Control and Fire Protection of Commercial Cooking Operations | 609.1 |
99—15 | Health Care Facilities Code | 611.1, 1105.5.2, 1105.10.1, 1105.10.2, 5306.4, 5306.5 |
101—15 | Life Safety Code | 1029.6.2 |
105—13 | Standard for Smoke Door Assemblies and Other Opening Protectives | 703.1.2 |
110—13 | Standard for Emergency and Standby Power Systems | 6604.1.2, 604.4, 604.5, 913.5.2, 913.5.3 |
111—13 | Standard on Stored Electrical Energy Emergency and Standby Power Systems | 604.1.2, 604.4, 604.5 |
120—15 | Standard for Fire Prevention and Control in Coal Mines | Table 2204.1 |
160—11 | Standard for the Use of Flame Effects Before an Audience | 308.3.2 |
170—15 | Standard for Fire Safety and Emergency Symbols | 1025.2.6.1 |
204—15 | Standard for Smoke and Heat Venting | Table 901.6.1, 910.5.1 |
211—13 | Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances | 603.2 |
241—13 | Standard for Safeguarding Construction, Alteration and Demolition Operations | 3301.1 |
253—15 | Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source | 804.3.1, 804.3.2, 804.4 |
260—13 | Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture | 805.1.1.1, 805.2.1.1, 805.3.1.1, 805.4.1.1 |
261—13 | Standard Method of Test for Determining Resistance of Mock-up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes | 805.2.1.1, 805.3.1.1, 805.4.1.1 |
265—11 | Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings in Full Height Panels and Walls | 803.5.1, 803.5.1.1, 803.5.1.2, 803.5.2, 803.6 |
286—15 | Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth | 803.1, 803.1.2, 803.1.2.1, 803.5.1, 803.5.2, 803.6, 803.7 |
289—13 | Standard Method of Fire Test for Individual Fuel Packages | 806.2, 807.4, 807.5.1.1, 808.3 |
303—11 | Fire Protection Standard for Marinas and Boatyards | 905.3.7, 3603.5, 3603.6, 3604.2 |
318—15 | Standard for the Protection of Semiconductor Fabrication Facilities | 2703.16 |
326—10 | Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning, or Repair | 3510.1 |
385—12 | Standard for Tank Vehicles for Flammable and Combustible Liquids | 5706.5.4.5, 5706.6, 5706.6.1 |
400—13 | Hazardous Materials Code | 5601.1.5, 6304.1.2, Table 6304.1.5(1), Table 6304.1.5(2) |
407—12 | Standard for Aircraft Fuel Servicing | 2006.2, 2006.3 |
409—11 | Standard for Aircraft Hangars | 914.8.3, Table 914.8.3, 914.8.3.1, 914.8.6 |
410—10 | Standard on Aircraft Maintenance | 2004.7 |
484—15 | Standard for Combustible Metals | Table 2204.1 |
495—13 | Explosive Materials Code | 202, 911.1, 911.4, 5601.1.1, 5601.1.5, 5604.2, 5604.6.2, 5604.6.3, 5604.7.1, 5605.1, 5606.1, 5606.5.2.1, 5606.5.2.3, 5607.1, 5607.9, 5607.11, 5607.15 |
498—13 | Standard for Safe Havens and Interchange Lots for Vehicles Transporting Explosives | 5601.1.2 |
505—13 | Fire Safety Standard for Powered Industrial Trucks, Including Type Designations, Areas of Use, Maintenance and Operation | 5003.7.3 |
654—13 | Standard for Prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids | Table 2204.1 |
655—12 | Standard for the Prevention of Sulfur Fires and Explosions | Table 2204.1 |
664—12 | Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities | Table 2204.1, 2805.3 |
701—10 | Standard Methods of Fire Tests for Flame-propagation of Textiles and Films | 806.2, 807.4, 807.5.1.2, 2603.5, 3104.2 |
703—15 | Standard for Fire Retardant-Wood and Fire-Retardant Coatings for Building Materials | 803.4 |
704—12 | Standard System for Identification of the Hazards of Materials for Emergency Response | 606.7, 202, 3104.2, 5003.2.2.1, 5003.2.2.2, 5003.5, 5003.10.2, 5005.1.10, 5005.2.1.1, 5005.4.4, 5503.4.1, 5704.2.3.2 |
720—15 | Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment | 915.5.1, 915.5.2, 915.6, Table 901.6.1, 901.6.3, 901.6.4 |
750—15 | Standard on Water Mist Fire Protection Systems | 202, Table 901.6.1, 904.11.1.1 |
914—10 | Code for Fire Protection of Historic Structures | 1103.1.1 |
1122—13 | Code for Model Rocketry | 5601.1.4 |
1123—14 | Code for Fireworks Display | 202, 5604.2, 5608.1, 5608.2.2, 5608.5, 5608.6 |
1124—06 | Code for the Manufacture, Transportation, Storage and Retail Sales of Fireworks and Pyrotechnic Articles | 202, 5601.1.3, 5604.2, 5605.1, 5605.3, 5605.4, 5605.5, 5609.1 |
1125—12 | Code for the Manufacture of Model Rocket and High Power Rocket Motors | 5601.1.4 |
1126—11 | Standard for the Use of Pyrotechnics Before a Proximate Audience | 5604.2, 5605.1, 5608.1, 5608.2.2, 5608.4, 5608.5 |
1127—13 | Code for High Power Rocketry | 5601.1.4 |
2001—15 | Standard on Clean Agent Fire Extinguishing Systems | Table 901.6.1, 904.10 |
UL | Underwriters Laboratories LLC 333 Pfingsten Road Northbrook, IL 60062 | |
Standard reference number | Title | Referenced in code section number |
10C—09 | Positive Pressure Fire Tests of Door Assemblies | 1010.1.10.1 |
30—95 | Metal Safety Cans—with revisions through July 2009 | 5003.9.10, 5005.1.10, 5705.2.4 |
58—96 | Steel Underground Tanks for Flammable and Combustible Liquids—with revisions through July 1998 | 5704.2.13.1.5 |
80—07 | Steel Tanks for Oil-Burner Fuels and Other Combustible Liquids— with revisions Through August 2009 | 610.2 |
87A—12 | Outline of Investigation for Power-Operated Dispensing Devices for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent | 2306.8.1 |
142—06 | Steel Aboveground Tanks for Flammable and Combustible Liquids—with revisions through February 12, 2010 | 610.2, 2306.2.3 |
199E—04 | Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers | 904.12.4.1 |
217—06 | Single and Multiple Station Smoke Alarms—with revisions through April 2012 | 907.2.11, 915.4.3 |
268—09 | Smoke Detectors for Fire Alarm Systems | 907.2.6.2, 907.2.11.7, 915.5.3 |
294—1999 | Access Control System Units—with revisions through September 2010 | 1010.1.9.6, 1010.1.9.8, 1010.1.9.9 |
300—05(R2010) | Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment— with revisions through July 16, 2010 | 904.12 |
300A—06 | Outline of Investigation for Extinguishing System Units for Residential Range Top Cooking Surfaces | 904.13 |
305—2012 | Panic Hardware | 1010.1.10.1 |
325—02 | Door, Drapery, Gate, Louver and Window Operators and Systems— with revisions through June 2013 | 503.5, 503.6 |
499—05 | Standard for Electrical Heating Appliances—with revisions through February 2013 | 610.6 |
710B—2011 | Recirculating Systems | 609.2, 904.12 |
723—08 | Standard for Test for Surface Burning Characteristics of Building Materials— with revisions through September 2010 | 202, 803.5.1, 803.5.2, 803.6, 803.7, 803.10, 804.1, 804.2.4202 |
790—04 | Standard Test Methods for Fire Tests of Roof Coverings— with revisions through October 2008 | 317.2, 317.3 |
793—08 | Automatically Operated Roof Vents for Smoke and Heat— with revisions through September 2011 | 910.3.1 |
864—03 | Control Units and Accessories for Fire Alarm Systems— with revisions through August 2012 | 909.12, 2311.7.2.1.1, 5808.5.2, 6004.2.2.10.1 |
900—04 | Air Filter Units—with revisions through February 2012 | 2404.7.8 |
924—06 | Standard for Safety Emergency Lighting and Power Equipment— with revisions through February 2011 | 1013.5, 3103.12.6.1 |
1037—99 | Antitheft Alarms and Devices—with revisions through December 2009 | 506.1 |
1275—05 | Flammable Liquid Storage Cabinets—with revisions through February 2010 | 5003.8.7.1, 5704.3.2.1.1 |
1313—93 | Standard for Nonmetallic Safety Cans for Petroleum Products— with revisions through November 2012 | 5003.9.10 |
1315—95 | Standard for Safety for Metal Waste Paper Containers— with revisions through September 2012 | 808.1, 808.2 |
1316—94 | Glass Fiber Reinforced Plastic Underground Storage Tanks for Petroleum Products, Alcohols, and Alcohol-gasoline Mixtures— with revisions through May 2006 | 5704.2.13.1.5 |
1363—07 | Relocatable Power Taps—with revisions through September 2012 | 605.4.1 |
1975—06 | Fire Tests for Foamed Plastics Used for Decorative Purpose | 807.4.2.1, 808.3 |
1994—04 | Standard for Luminous Egress Path Marking Systems— with revisions through November 2010 | 1008.2.1, 1025.2.1, 1025.2.3, 1025.2.4, 1025.4 |
2017—08 | General-Purpose Signaling Devices and Systems— with revisions through May 2011 | 2311.7.2.1.1, 5808.5.2, 6004.2.2.10.1 |
2034—08 | Single and Multiple Station Carbon Monoxide Alarms— with revisions through February 2009 | 915.4.2, 915.4.3, 1103.9 |
2075—2013 | Standard for Gas and Vapor Detectors and Sensors | 915.5.1, 915.5.3, 2311.7.2.1.1, 5808.5.2, 6004.2.2.10.1 |
2079—04 | Tests for Fire Resistance of Building Joint Systems— with revisions through December 2012 | 202 |
2085—97 | Protected Above-ground Tanks for Flammable and Combustible Liquids— with revisions through September 2010 | 202, 2306.2.2, 2306.2.3, 5704.2.7.4, 5704.2.9.2.3, 5704.2.9.7.4, 5705.3.8.2 |
2196—2001 | Tests for Fire Resistive Cables—with revisions through March 2012 | 604.3, 913.2.2 |
2200—2012 | Stationary Engine Generator Assemblies—with revisions through June 2013 | 604.1.1 |
2208—2010 | Solvent Distillation Units—with revisions through March 2011 | 5705.4.1 |
2245—06 | Below-grade Vaults for Flammable Liquid Storage Tanks | 5704.2.8.1 |
2335—10 | Fire Tests of Storage Pallets—with revisions through September 2012 | 3206.4.1.1, 3208.2.1 |
2360—00 | Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semi-Conductor Tool Construction— with revisions through May 2013 | 2703.10.1.2 |
USC | United States Code c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 | |
Standard reference number | Title | Referenced in code section number |
18 USC Part 1, Chapter 40 | Importation, Manufacture, Distribution and Storage of Explosive Materials | 202 |
21 USC Chapter 9 | United States Food, Drug and Cosmetic Act | 4002.1 |