Heads up: There are no amended sections in this chapter.

Chapter 6 [RE] Referenced Standards

AMENDMENT
This section has been amended at the state or city level.

AAMA

American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg IL60173-4268

AAMA/WDMA/CSA 101/I.S.2/A C440—17

North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights

R402.4.3

ACCA

Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206

Manual J—16

Residential Load Calculation Eighth Edition

R403.7

Manual S—14

Residential Equipment Selection

R403.7

APSP

The Association of Pool & Spa Professionals
2111 Eisenhower Avenue, Suite 500
Alexandria, VA 22314

ANSI/APSP/ICC 14—2014

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2011

American National Standard for Residential Swimming Pool and Spa Energy Efficiency—includes Addenda A Approved January 9, 2013

R403.12

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta, GA 30329

ASHRAE—2017

ASHRAE Handbook of Fundamentals

R402.1.5

ASHRAE—2001

2001 ASHRAE Handbook of Fundamentals

Table R405.5.2(1)

ASHRAE 193—2010(RA 2014)

Method of Test for Determining the Airtightness of HVAC Equipment

R403.3.2.1

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken, PA 19428-2959

C1363—11

Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus

R303.1.4.1

E283—04(2012)

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen

R402.4.4

E779—10

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

R402.4.1.2

E1827—11

Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door

R402.4.1.2

CSA

CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516

AAMA/WDMA/CSA 101/I.S.2/A440—17

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3

CSA B55.1—2015

Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units

R403.5.4

CSA B55.2—2015

Drain Water Heat Recovery Units

R403.5.4

DASMA

Door & Access Systems Manufacturers Association
1300 Sumner Avenue
Cleveland, OH 44115-2851

105—2016

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors

R303.1.3

HVI

Home Ventilating Institute
1000 North Rand Road, Suite 214
Wauconda, IL 60084

916—09

Airflow Test Procedure

Table R403.6.1

ICC

International Code Council, Inc.
500 New Jersey Avenue NW
6th Floor
Washington DC20001

ANSI/APSP/ICC 14—2014

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2011

American National Standard for Residential Swimming Pool and Spa Energy Efficiency—includes Addenda A Approved January 9, 2013

R403.12

ICC 400—17

Standard on the Design and Construction of Log Structures

R402.1

IEBC—18

International Existing Building Code®

R501.4

IECC—18

International Energy Conservation Code®

R101.4.1, R403.8

IECC—15

2015 International Energy Conservation Code®

Table R406.4

IECC—09

2009 International Energy Conservation Code®

R406.2

IECC—06

2006 International Energy Conservation Code®

R202

IFC—18

International Fire Code®

R201.3, R501.4

IFGC—18

International Fuel Gas Code®

R201.3, R501.4

NSPC—18

National Standard Plumbing Code

R201.3, R501.4

IPSDC—18

International Private Sewage Disposal Code®

R501.4

IPMC—18

International Property Maintenance Code®

R501.4

 

** NSPC—18 is non-ICC and is published by the National Association of Plumbing-Heating-Cooling Contractors

 

ANSI/RESNET/ICC 301—2014

Standard for the Calculation and Labeling of the Energy Performance of Low-rise Residential Buildings using an Energy Rating Index First Published March 7, 2014—Republished January 2016

R406.3

ANSI/RESNET/ICC 380—2016

Standard for Testing Airtightness for Building Enclosures, Airtightness of Heating and Cooling Air Distribution Systems and Airflow of Mechanical Ventilation Systems—Republished January 2016

R402.4.1.2

IEEE

Institute of Electrical and Electronic Engineers, Inc.
3 Park Avenue, 17th Floor
New York, NY 10016-5997

515.1—2012

IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications

R403.5.1.2

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471

70—17

National Electrical Code

R501.4

NFRC

National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt, MD 20770

100—2017

Procedure for Determining Fenestration Products U-factors

R303.1.3

200—2017

Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence

R303.1.3

400—2017

Procedure for Determining Fenestration Product Air Leakage

R402.4.3

RESNET

Residential Energy Services Network, Inc.
P.O. Box 4561
Oceanside, CA 92052-4561

ANSI/RESNET/ICC 301—2014

Standard for the Calculation and Labeling of the Energy Performance of Low-rise Residential Buildings using an Energy Rating Index First Published March 7, 2014—Republished January 2016

R406.3, R406.6.1, R406.6.5

ANSI/RESNET/ICC 380—2016

Standard for Testing Airtightness for Building Enclosures, Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems—Republished January 2016

R402.4.1.2

UL

UL LLC
333 Pfingsten Road
Northbrook, IL 60062

127—11

Standard for Factory Built Fireplaces—with Revisions through May 2015

R402.4.2

515—11

Electrical Resistance Heat Tracing for Commercial and Industrial Applications Including Revisions through July 2015

R403.5.1.2

US-FTC

United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580

CFR Title 16 (2015)

R-value Rule

R303.1.4

WDMA

Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington, DC 20036-3309

AAMA/WDMA/CSA 101/I.S.2/A440—17

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3

UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING