AAMA
Suite 550
AAMA/WDMA/CSA 101/I.S.2/A C440—17
North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights
Table C402.5.2
AHAM
ANSI/AHAM RAC-1—2008
Room Air Conditioners
Table C403.3.2(3)
AHAM HRF-1—2016
Energy, Performance and Capacity of Household Refrigerators, Refrigerator-Freezers and Freezers
AHRI
ISO/AHRI/ASHRAE 13256-1 (1998 RA2014)
Water-to-Air and Brine-to-Air Heat Pumps—Testing and Rating for Performance
Table C403.3.2(2)
ISO/AHRI/ASHRAE 13256-2 (1998 RA2014)
Water-to-Water and Brine-to-Water Heat Pumps —Testing and Rating for Performance
Table C403.3.2(2)
210/240—2016
Performance Rating of Unitary Air-conditioning and Air-source Heat Pump Equipment
Table C403.3.2(1), Table C403.3.2(2)
310/380—2014 (CSA-C744-04)
Standard for Packaged Terminal Air Conditioners and Heat Pumps
Table C403.3.2(3)
340/360—2015
Performance Rating of Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment
Table C403.3.2(1), Table C403.3.2(2)
365(I-P)—2009
Commercial and Industrial Unitary Air-conditioning Condensing Units
Table C403.3.2(1), Table C403.3.2(6)
390 (I-P)—2015
Performance Rating of Single Package Vertical Air-conditioners and Heat Pumps
440—2008
Performance Rating of Room Fan Coils—with Addendum 1
C403.11.3
460—2005
Performance Rating of Remote Mechanical-draft Air-cooled Refrigerant Condensers
Table C403.3.2(8)
550/590 (I-P)—2015
Performance Rating of Water-chilling and Heat Pump Water-heating Packages Using the Vapor Compression Cycle
C403.3.2.1, Table C403.3.2(7)
1160 (I-P) —2014
Performance Rating of Heat Pump Pool Heaters
Table C404.2
1200 (I-P)—2013
Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets
C403.10, Table C403.10.1(1), Table C403.10.1(2)
AMCA
205—12
Energy Efficiency Classification for Fans
C403.8.3
220—08 (R2012)
Laboratory Methods of Testing Air Curtain Units for Aerodynamic Performance Rating
C402.5.6
500D—12
Laboratory Methods for Testing Dampers for Rating
C403.7.7
ANSI
Z21.10.3/CSA 4.3—11
Gas Water Heaters, Volume III—Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous
Table C404.2
Z21.47/CSA 2.3—12
Gas-fired Central Furnaces
Table C403.3.2(4)
Z83.8/CSA 2.6—09
Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces
Table C403.3.2(4)
APSP
14—2014
American National Standard for Portable Electric Spa Energy Efficiency
C404.8
ASHRAE
ANSI/ASHRAE/ACCA Standard 183—2007 (RA2014)
Peak Cooling and Heating Load Calculations in Buildings, Except Low-rise Residential Buildings
C403.1.1
ASHRAE—2016
ASHRAE HVAC Systems and Equipment Handbook
C403.1.1
ISO/AHRI/ASHRAE 13256-1 (1998 RA2014)
Water-to-Air and Brine-to-Air Heat Pumps—Testing and Rating for Performance
Table C403.3.2(2)
ISO/AHRI/ASHRAE 13256-2 (1998 RA2014)
Water-to-Water and Brine-to-Water Heat Pumps—Testing and Rating for Performance
Table C403.3.2(2)
90.1—2016
Energy Standard for Buildings Except Low-rise Residential Buildings
C401.2, Table C402.1.3, Table C402.1.4, C406.2, C502.1, C503.1, C504.1
140—2014
Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs
C407.6.1
ASME
ASME A17.1—2016/CSA B44—16
Safety Code for Elevators and Escalators
C405.8.2
ASTM
C90—14
Specification for Load-bearing Concrete Masonry Units
C1363—11
Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
C303.1.4.1, Table C402.1.4, 402.2.7
C1371—15
Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers
Table C402.3
C1549—09(2014)
Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer
Table C402.3
D1003—13
Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics
C402.4.2.2
E283—04(2012)
Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen
C402.5.1.2.2, Table C402.5.2, C402.5.7
E408—13
Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques
Table C402.3
E779—10
Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
C402.5
E903—12
Standard Test Method Solar Absorptance, Reflectance and Transmittance of Materials Using Integrating Spheres (Withdrawn 2005)
Table C402.3
E1677—11
Specification for Air Barrier (AB) Material or Systems for Low-rise Framed Building Walls
C402.5.1.2.2
E1827—11
Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door
C402.5, C406.9
E1918—06(2015)
Standard Test Method for Measuring Solar Reflectance of Horizontal or Low-sloped Surfaces in the Field
Table C402.3
E1980—11
Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces
Table C402.3
E2178—13
Standard Test Method for Air Permanence of Building Materials
C402.5.1.2.1
CRRC
ANSI/CRRC-S100—2016
Standard Test Methods for Determining Radiative Properties of Materials
Table C402.3, C402.3.1
CSA
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights
Table C402.5.2
CSA B55.1—2015
Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units
C404.8
CSA B55.2—2015
Drain Water Heat Recovery Units
C404.8
CTI
ATC 105 (00)
Acceptance Test Code for Water Cooling Tower
Table C403.3.2(8)
ATC 105S—11
Acceptance Test Code for Closed Circuit Cooling Towers
Table C403.3.2(8)
ATC 106—11
Acceptance Test for Mechanical Draft Evaporative Vapor Condensers
Table C403.3.2(8)
STD 201—11
Standard for Certification of Water Cooling Towers Thermal Performances
Table C403.3.2(8)
DASMA
105—2016
Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors
C303.1.3, Table C402.5.2
DOE
1000 Independence Avenue SW
10 CFR, Part 430—2015
Energy Conservation Program for Consumer Products: Test Procedures and Certification and Enforcement Requirement for Plumbing Products; and Certification and Enforcement Requirements for Residential Appliances; Final Rule
Table C403.3.2(4), Table C403.3.2(5), Table C404.2
10 CFR, Part 430, Subpart B, Appendix N—(2015)
Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers
C202
10 CFR, Part 431—2015
Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures and Efficiency Standards; Final Rules
Table C403.3.2(5), C405.6, Table C405.6, C405.7
10 CFR 431 Subpart B App B
Uniform Test Method for Measuring Nominal Full Load Efficiency of Electric Motors
C403.8.4, Table C405.7(1), Table C405.7(2), Table C405.7(3), C405.7(4)
NAECA 87—(88)
National Appliance Energy Conservation Act 1987 [Public Law 100-12 (with Amendments of 1988-P.L. 100-357)]
Table C403.3.2(1), Table C403.3.2(2), Table C403.3.2(4)
ICC
6th Floor
IFC—18
International Fire Code®
C201.3, C501.4
IMC—18
International Mechanical Code®
C403.7.7, C403.2.2, C403.7.1, C403.7.2, C403.7.4, C403.7.5, C403.11.1, C403.11.2.1, C403.11.2.2, C403.6, C403.6.6, C406.6, C501.4
IPC—18 NSPC—18
International Plumbing Code® National Standard Plumbing Code
C201.3, C501.4
IPMC—18
International Property Maintenance Code®
C501.4
IPSDC—18
International Private Sewage Disposal Code®
C501.4
** NSPC—18 is non-ICC and is published by the National Association of Plumbing-Heating-Cooling Contractors
IEEE
IEEE 515.1—2012
IEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Commercial Applications
C404.6.2
IES
ANSI/ASHRAE/IESNA 90.1—2016
Energy Standard for Buildings, Except Low-rise Residential Buildings
C401.2, Table C402.1.3, Table C402.1.4, C406.2, C502.1, C503.1, C504.1
ISO
ISO/AHRI/ASHRAE 13256-1(1998 RA2014)
Water-to-Air and Brine-to-Air Heat Pumps -Testing and Rating for Performance
ISO/AHRI/ASHRAE 13256-2(1998 RA2014)
Water-to-Water and Brine-to-Water Heat Pumps -Testing and Rating for Performance
C403.3.2(2)
NEMA
MG1—2014
Motors and Generators
C202
NFPA
70—17
National Electrical Code
C501.4
NFRC
200—2017
Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence
C303.1.3, C402.4.1.1
SMACNA
UL
710—12
Exhaust Hoods for Commercial Cooking Equipment—with Revisions through November 2013
C403.7.5
727—06
Oil-fired Central Furnaces—with Revisions through October 2013
Table C403.3.2(4)
1784—01
Air Leakage Tests of Door Assemblies—with Revisions through February 2015
C402.5.3
US-FTC
CFR Title 16 (2015)
R-value Rule
C303.1.4
WDMA
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights