ADOPTS WITH AMENDMENTS:

International Residential Code 2012 (IRC 2012)

Part I — Administrative

Part II — Definitions

Part III — Building Planning and Construction

Part IV — Energy Conservation

Part V — Mechanical

Part VI — Fuel Gas

Part VII — Plumbing

Part VIII — Electrical

Part IX — Referenced Standards

Heads up: There are no amended sections in this chapter.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.

AAMA American Architectural Manufacturers Association
1827 Walden Office Square, Suite 550
Schaumburg, IL 60173
 
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standards/Specifications for Windows,
Doors and Skylights
R308.6.9, R612.3, N1102.4.3
450—09 Voluntary Performance Rating Method for Mulled Fenestration Assemblies R612.8
506—08 Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration Products R612.6.1
711—07 Voluntary Specification for Self-adhering Flashing Used for Installation of
Exterior Wall Fenestration Products
R703.8
ACI American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
 
Standard
reference
number
Title Referenced
in code
section number
318—11 Building Code Requirements for Structural Concrete R301.2.2.2.4, R301.2.2.3.4, Table R402.1.2(2),
R402.2, R404.1.2, Table R404.1.2(5),
Table R404.1.2(7), Table R404.1.2(8), Table R404.1.2(9),
R404.1.2.1, R404.1.2.3, R404.1.2.4, R404.1.4.2, R404.5.1, R611.1,
R611.1.1, R611.1.2, R611.2, R611.5.1, R611.6.1, R611.8.2,
R611.9.2, R611.9.3
332—10 Code Requirements for Residential Concrete Construction R402.2, R403.1, R404.1.2, R404.1.2.4,
R404.1.4.2, R506.1
530—11 Building Code Requirements for Masonry Structures R404.1.1, R606.1, R606.1.1,
R606.12.1, R606.12.2.2.2, R606.12.2.3.1,
R606.12.3.1, Table R703.4
530.1—11 Specification for Masonry Structures R404.1.1, R606.1, R606.1.1, R606.12.1, R606.12.2.2.1,
R606.12.2.2.2, R606.12.3.1, Table R703.4
ACCA Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
Title Referenced
in code
section number
Manual D—-09 Residential Duct Systems M1601.1, M1602.2
Manual J—-11 Residential Load Calculation—Eighth Edition N1103.6, M1401.3
Manual S—-10 Residential Equipment Selection N1103.6, M1401.3
AFPA American Forest and Paper Association
1111 19th Street, NW, Suite 800
Washington, DC 20036
 
Standard
reference
number
Title Referenced
in code
section number
AFPA—2012 Span Tables for Joists and Rafters R502.3, R802.4, R802.5
ANSI/AF&PA
WFCM—2012
Wood Frame Construction Manual for One- and
Two-family Dwellings
R301.1.1, R301.2.1.1,
R611.9.2, R611.9.3, R611.10
NDS—2012 National Design Specification (NDS) for Wood Construction—
with 2012 Supplement
R404.2.2, R502.2, Table R503.1,
R602.3, Table R602.3.1, R611.9.2, R611.9.3, R802.2
PWF—2007 Permanent Wood Foundation Design Specification R401.1, R404.2.3
AISI American Iron and Steel Institute
1140 Connecticut Ave, Suite 705
Washington, DC 20036
 
Standard
reference
number
Title Referenced
in code
section number
AISI S100—07/S2—10 North American Specification for the Design of Cold-formed
Steel Structural Members, with Supplement 2, dated 2010
R505.1.3, R603.6, R611.9.2,
R611.9.3, R804.3.7
AISI S230—07/S2—08 Standard for Cold-formed Steel Framing—Prescriptive Method
for One- and Two-family Dwellings, with Supplement 2, dated 2008
R301.1.1, R301.2.1.1, R301.2.2.3.1,
R301.2.2.3.5, R603.6, R603.9.4.1, R603.9.4.2, R611.9.2, R611.9.3, R611.10
AITC American Institute of Timber Construction
7012 S. Revere Parkway, Suite 140
Centennial, CO 80112
 
Standard
reference
number
Title Referenced
in code
section number
ANSI/AITC A 190.1—07 Structural Glued-laminated Timber R502.1.5,R602.1.2,R802.1.4
ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A108.1A—99 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar R702.4.1
A108.1B—99 Installation of Ceramic Tile, Quarry Tile on a Cured
Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar
R702.4.1
A108.4—99 Installation of Ceramic Tile with Organic Adhesives or
Water-Cleanable Tile-setting Epoxy Adhesive
R702.4.1
A108.5—99 Installation of Ceramic Tile with Dry-set Portland
Cement Mortar or Latex Portland Cement Mortar
R702.4.1
A108.6—99 Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting
and -grouting Epoxy
R702.4.1
A108.11—99 Interior Installation of Cementitious Backer Units R702.4.1
A118.1—99 American National Standard Specifications for Dry-set Portland Cement Mortar R702.4.1
A118.3—99 American National Standard Specifications for Chemical-resistant,
Water-cleanable Tile-setting and -grouting Epoxy, and
Water-cleanable Tile-setting Epoxy Adhesive
R702.4.1
A118.10—99 Specification for Load-bearing, Bonded, Waterproof Membranes for
Thin-set Ceramic Tile and Dimension Stone Installation
P2709.2,P2709.2.4
A136.1—99 American National Standard Specifications for Organic Adhesives for
Installation of Ceramic Tile
R702.4.1
A137.1—88 American National Standard Specifications for Ceramic Tile R702.4.1
A208.1—2009 Particleboard R503.3.1,R605.1
LC1/CSA 6.26—05 Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) G2414.5.3
LC4—07 Press-connect Copper and Copper-alloy Fittings for
Use in Fuel Gas Distribution Systems
G2414.10.2
Z21.1—05 Household Cooking Gas Appliances G2447.1
Z21.5.1/CSA 7.1—06 Gas Clothes Dryers—Volume I—Type I Clothes Dryers G2438.1
Z21.8—94 (R2002) Installation of Domestic Gas Conversion Burners G2443.1
Z21.10.1/CSA 4.1—09 Gas Water Heaters—Volume I—Storage Water Heaters with Input Ratings
of 75,000 Btu per hour or Less
G2448.1
Z21.10.3/CSA 4.3—04 Gas Water Heaters—Volume III—Storage Water Heaters with Input Ratings
above 75,000 Btu per hour, Circulating and Instantaneous
G2448.1
Z21.11.2—07 Gas-fired Room Heaters—Volume II—Unvented Room Heaters G2445.1
Z21.13/CSA 4.9—10 Gas-fired Low-pressure Steam and Hot Water Boilers G2452.1
Z21.15/CSA 9.1—09 Manually Operated Gas Valves for Appliances, Appliance
Connector Valves and Hose End Valves
Table G2420.1.1
Z21.22—99 (R2003) Relief Valves for Hot Water Supply Systems—with Addenda Z21.22a—2000 (R2003)
and 21.22b—2001 (R2003)
P2803.2,P2803.7
Z21.24—97 Connectors for Gas Appliances G2422.1
Z21.40.1/
CSA 2.91—96 (R2002)
Gas-fired, Heat-activated Air-conditioning and Heat Pump Appliances G2449.1
Z21.40.2/
CSA 2.92—96 (R2002)
Gas-fired, Work-activated Air-conditioning and Heat
Pump Appliances (Internal Combustion)
G2449.1
Z21.42—93 (R2002) Gas-fired Illuminating Appliances G2450.1
Z21.47/CSA 2.3—06 Gas-fired Central Furnaces G2442.1
Z21.50/CSA 2.22—07 Vented Gas Fireplaces G2434.1
Z21.56/CSA 4.7—06 Gas-fired Pool Heaters G2441.1
Z21.58—95/CSA 1.6—07 Outdoor Cooking Gas Appliances G2447.1
Z21.60/CSA 2.26—03 Decorative Gas Appliances for Installation in Solid Fue-burning Fireplaces G2432.1
Z21.75/CSA 6.27—07 Connectors for Outdoor Gas Appliances G2422.1
Z21.80—03 Line Pressure Regulators G2421.1
Z21.83—98 Fuel Cell Power Plants M1903.1
Z21.84—02 Manually Listed, Natural Gas Decorative Gas Appliances for Installation in
Solid Fuel-burning Fireplaces—with Addenda Z21.84a—2003
G2432.1,G2432.2
Z21.86—04 Gas-fired Vented Space Heating Appliances G2436.1,G2437.1,G2446.1
Z21.88—02 Vented Gas Fireplace Heaters—with Addenda A21.88a—2003 and Z21.88b—2004 G2435.1
Z21.91—01 Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters G2445.7.1
Z21.97—09 Outdoor Decorative Appliances G2454.1
Z83.6—90 (R1998) Gas-fired Infrared Heaters G2451.1
Z83.8—02 Gas-fired Unit Heaters and Gas-fired Duct Furnaces—with Addenda Z83.8a—2003 G2444.1
Z83.19—01 (R2005) Gas-fuel High-intensity Infrared Heaters G2451.1
Z83.20—08 Gas-fired Low-intensity Infared Heaters Outdoor Decorative Appliances G2451.1
Z97.1—09 Safety Glazing Materials Used in Buildings—Safety Performance Specifications
and Methods of Test
R308.1.1,R308.3.1
Z124.1—95 Plastic Bathtub Units Table P2701.1
Z124.2—95 Plastic Shower Receptors and Shower Stalls TableP2701.1
Z124.3—95 Plastic Lavatories TableP2701.1,P2711.1,P2711.2
Z124.4—96 Plastic Water Closet Bowls and Tanks TableP2701.1,P2712.1
Z124.6—97 Plastic Sinks TableP2701.1
APA APA—The Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
 
Standard
reference
number
Title Referenced
in code
section number
ANSI/APA PRP 210—08 Standard for Performance-rated Engineered Wood Siding R604.1, TableR703.4
APA E30—03 Engineered Wood Construction Guide TableR503.2.1.1(1),R503.2.2,
R803.2.2,R803.2.3
APSP The Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314
 
Standard
reference
number
Title Referenced
in code
section number
ANSI/APSP 7—06 Standard for Suction Entrapment Avoidance in Swimming Pools Wading Pools, Spas,
Hot Tubs and Catch Basins
AG106.1
ANSI/NSPI 3—99 Standard for Permanently Installed Residential Spas AG104.1
ANSI/NSPI 4—2007 Standard for Above-ground/On-ground Residential Swimming Pools AG103.2
ANSI/NSPI 5—2003 Standard for Residential In-ground Swimming Pools AG103.1
ANSI/NSPI 6—99 Standard for Residential Portable Spas AG104.2
ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191
 
Standard
reference
number
Title Referenced
in code
section number
5—11 Building Code Requirements for Masonry Structures R404.1.1,R606.1,R606.1.1,
R606.12.1,R606.12.2.2.1,R606.12.2.2.2,
R606.12.3.1, Table R703.4
6—11 Specification for Masonry Structures R606.1,R606.1.1,
R606.12.1,R606.12.2.2.1,R606.12.2.2.2,
R606.12.3.1, Table R703.4
7—10 Minimum Design Loads for Buildings and Other Structures R301.2.1.1,R301.2.1.2,
R301.2.1.5,R301.2.1.5.1, Table R611.6(1),
Table R611.6(2), Table R611.6(3),
Table R611.6(4), Table R611.7(1A),R611.9.2,
R611.9.3, TableR802.11, AH107.4.3
24—05 Flood-resistant Design and Construction R301.2.4,R301.2.4.1,R322.1,
R322.1.1,R322.1.6,R322.1.9,R322.2.2, R3223.3,AG103.3
32—01 Design and Construction of Frost-protected Shallow Foundations R403.1.4.1
ASHRAE American Society of Heating, Refrigerating
and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
 
Standard
reference
number
Title Referenced
in code
section number
ASHRAE—2009 ASHRAE Handbook of Fundamentals N1102.1.4, Table N1105.5.2(1), P3001.2, P3101.4, P3103.2
ASHRAE 193—2010 Method of Test for Determining Air Tightness of HVAC Equipment N1103.2.2.1
34—2010 Designation and Safety Classification of Refrigerants M1411.1
ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title Referenced
in code
section number
ASME/A17.1—2007/
CSA B44—2007
Safety Code for Elevators and Escalators—with A17.1a/CSA B44a—08 Addenda R321.1
A18.1—2008 Safety Standard for Platforms and Stairway Chair Lifts R321.2
A112.1.2—2004 Air Gaps in Plumbing Systems Table P2902.3,P2902.3.1
A112.1.3—2000
(Reaffirmed 2005)
Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances Table P2701.1,P2902.3.1
A112.3.1—2007 Stainless Steel Drainage Systems for Sanitary, DWV, Storm
and Vacuum Applications Above and Below Ground
Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, Table P3302.1
A112.3.4—2000 (R2004) Macerating Toilet Systems and Related Components Table P2701.1,P3007.5
A112.4.1—1993 (R2002) Water Heater Relief Valve Drain Tubes P2803.6.1
A112.4.2—2003 (R2008) Water-closet Personal Hygiene Devices P2722.5
A112.4.3—1999 (R2004) Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System P3003.19
A112.6.1M—1997 (R2002) Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use Table P2701.1,P2702.4
A112.6.2—2000 (R2004) Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks Table P2701.1,P2702.4
A112.6.3—2001 (R2007) Floor and Trench Drains Table P2701.1
A112.14.1—03
(Reaffirmed 2008)
Backwater Valves P3008.2
A112.18.1—2005/
CSA B125.1—2010
Plumbing Supply Fittings Table P2701.1,P2708.4, P2708.5,P2722.1,P2902.2
A112.18.2—2005/
CSA B125.2—2005
Plumbing Waste Fittings with 2007 and 2008 Supplements Table P2701.1,P2702.2
A112.18.3—2002
(Reaffirmed 2008)
Performance Requirements for Backflow Protection Devices and
Systems in Plumbing Fixture Fittings
P2708.4,P2722.3
A112.18.6/
CSA B125.6—2009
Flexible Water Connectors P2905.7
A112.19.1M/
CSA B45.2—2008
Enameled Cast-iron and Enameled Steel Plumbing Fixtures Table P2701.1,P2711.1
A112.19.2—2008/
CSA B45.1—2008
Ceramic Plumbing Fixtures Table P2701.1,P2705.1,P2711.1,P2712.1,P2712.2,P2712.9
A112.19.3—2008/
CSA B45.4—2008
Stainless Steel Plumbing Fixtures Table P2701.1,P2705.1,P2711.1,P2712.1
A112.19.4M—1994
(R2004)
Porcelain-enameled-formed Steel Plumbing Fixtures—with
1998 and 2000 Supplements
Table P2701.1,P2711.1
A112.19.5/
CSA B45.15—2009
Trim for Water-closet Bowls, Tanks and Urinals Table P2701.1
A112.19.7/
CSA B45.10—2009
Hydromassage Bathtub Appliances Table P2701.1
A112.19.12—2006 Wall-mounted and Pedestal-mounted, Adjustable
and Pivoting Lavatory and Sink Carrier Systems
Table P2701.1,P2711.4,P2714.2
A112.19.15—2005 Bathtub/Whirlpool Bathtubs with Pressure-sealed Doors Table P2701.1,P2713.2
B1.20.1—1983 (R2006) Pipe Threads, General-purpose (Inch) G2414.9,P3003.3.3,P3003.5.3,
P3003.10.4,P3003.12.1,P3003.14.3
B16.3—2006 Malleable-iron-threaded Fittings, Classes 150 and 300 Table P2905.6
B16.4—2006 Gray-iron-threaded Fittings Classes, 125 and 250 Table P2905.6, Table P3002.3
B16.9—2007 Factory-made, Wrought-steel Buttwelding Fittings Table P2905.6
B16.11—2005 Forged Fittings, Socket-welding and Threaded Table P2905.6
B16.12—1998 Cast-iron-threaded Drainage Fittings Table P2905.6, Table P3002.3 (R2006)
B16.15—2006 Cast-bronze-threaded Fittings Table P2905.6, Table P3002.3
B16.18—2001 (R2005) Cast-copper-alloy Solder Joint Pressure Fittings Table P2905.6, Table P3002.3
B16.22—2001(R2005) Wrought-copper and Copper-alloy Solder Joint Pressure Fittings Table P2905.6, Table P3002.3
B16.23—2002 (R2006) Cast-copper-alloy Solder Joint Drainage Fittings (DWV) Table P2905.6, Table P3002.3
B16.26—2006 Cast-copper-alloy Fittings for Flared Copper Tubes Table P2905.6, Table P3002.3
B16.28—1994 Wrought-steel Buttwelding Short Radius Elbows and Returns Table P2905.6
B16.29—2007 Wrought-copper and Wrought-copper-alloy Solder Joint Drainage Fittings (DWV) Table P2905.6,
Table P3002.3
B16.33—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in Gas Piping
Systems up to 125 psig (Sizes 1/2 through 2)
Table G2420.1.1
B16.44—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in
Above-ground Piping Systems up to 5 psi
Table G2420.1.1
B36.10M—2004 Welded and Seamless Wrought-steel Pipe G2414.4.2
BPVC—2007 ASME Boiler and Pressure Vessel Code (2007 Edition) M2001.1.1,G2452.1
CSD-1—2009 Controls and Safety Devices for Automatically Fired Boilers M2001.1.1,G2452.1
ASSE American Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
 
Standard
reference
number
Title Referenced
in code
section number
1001—2008 Performance Requirements for Atmospheric-type Vacuum Breakers Table P2902.3,P2902.3.2
1002—2008 Performance Requirements for Anti-siphon Fill Valves for
Water Closet Flush Tank
Table P2701.1, Table P2902.3,P2902.4.1
1003—2009 Performance Requirements for Water-pressure-reducing
Valves for Domestic Water Distribution Systems
P2903.3.1
1008—2006 Performance Requirements for Plumbing Aspects of
Residential Food Waste Disposer Units
Table P2701.1
1010—2004 Performance Requirements for Water Hammer Arresters P2903.5
1011—2004 Performance Requirements for Hose Connection Vacuum Breakers Table P2902.3,P2902.3.2
1012—2009 Performance Requirements for Backflow Preventers
with Intermediate Atmospheric Vent
Table P2902.3,P2902.3.3,P2902.5.1,P2902.5.5
1013—2009 Performance Requirements for Reduced Pressure Principle Backflow Preventers
and Reduced Pressure Principle Fire Protection Backflow Preventers
Table P2902.3,P2902.3.5,
P2902.5.1,P2902.5.5
1015—2009 Performance Requirements for Double Check Backflow Prevention Assemblies
and Double Check Fire Protection Backflow Prevention Assemblies
Table P2902.3,P2902.3.6
1016—2010 Performance Requirements for Automatic Compensating
Valves for Individual Showers and Tub/Shower Combinations
Table P2701.1,P2708.3,P2722.2
1017—2010 Performance Requirements for Temperature-actuated Mixing Valves for
Hot Water Distribution Systems
P2724.1,P2802.2
1019—2010 Performance Requirements for Freeze-resistant, Wall Hydrants,
Vacuum Breaker, Draining Types
Table P2701.1,P2902.3
1020—2004 Performance Requirements for Pressure Vacuum Breaker Assembly Table P2902.3,P2902.3.4
1023—2010 Performance Requirements for Hot Water Dispensers, Household-storage-
type—Electrical
Table P2701.1
1024—2004 Performance Requirements for Dual Check Backflow Preventers, Anti-siphon-type,
Residential Applications
Table P2902.3
1035—2008 Performance Requirements for Laboratory Faucet Backflow Preventers Table P2902.3,P2902.3.2
1037—2010 Performance Requirements for Pressurized Flushing Devices
(Flushometer) for Plumbing Fixtures
Table P2701.1
1047—2009 Performance Requirements for Reduced Pressure Detector Fire
Protection Backflow Prevention Assemblies
Table P2902.3,P2902.3.5
1048—2009 Performance Requirements for Double Check Detector Fire
Protection Backflow Prevention Assemblies
Table P2902.3,P2902.3.6
1050—2009 Performance Requirements for Stack Air Admittance
Valves for Sanitary Drainage Systems
P3114.1
1051—2009 Performance Requirements for Individual and Branch-type Air Admittance
Valves for Plumbing Drainage Systems
P3114.1
1052—2004 Performance Requirements for Hose Connection Backflow Preventers Table P2701.1,
Table P2902.3,P2902.3.2
1056—2010 Performance Requirements for Spill-resistant Vacuum Breakers Table P2902.3,P2902.3.4
1060—2006 Performance Requirements for Outdoor Enclosures for Fluid-conveying Components P2902.6.1
1061—2010 Performance Requirements for Removable and Nonremovable Push Fit Fittings Table P2905.6
1062—2006 Performance Requirements for Temperature-actuated, Flow Reduction (TAFR)
Valves for Individual Supply Fittings
Table P2701.1,P2724.2
1066—2009 Performance Requirements for Individual Pressure Balancing In-line
Valves for Individual Fixture Fittings
P2722.4
1070—2004 Performance Requirements for Water-temperature-limiting Devices P2713.3,P2721.2
ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
 
Standard
reference
number
Title Referenced
in code
section number
A 36/A 36M—08 Specification for Carbon Structural Steel R606.15, R611.5.2.2
A 53/A 53M—07 Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless R402.3,
Table M2101.1, G2414.4.2, Table P2905.4,
Table P2905.5, Table P3002.1(1)
A 74—09 Specification for Cast-iron Soil Pipe and Fittings Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3005.2.9, Table P3302.1
A 82/A 82M—05a Specification for Steel Wire, Plain, for Concrete Reinforcement R606.15
A 106/A 106M—08 Specification for Seamless Carbon Steel Pipe for High-temperature Service Table M2101.1, G2414.4.2
A 153/A 153M—05 Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware R317.3, Table R606.15.1
A 167—99 (2009) Specification for Stainless and Heat-resisting Chromium-nickel
Steel Plate, Sheet and Strip
R606.15, Table R606.15.1
A 240/A 240M—09a Standard Specification for Chromium and Chromium-nickel Stainless
Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications
Table R905.10.3(1)
A 254—97 (2007) Specification for Copper Brazed Steel Tubing Table M2101.1, G2414.5.1
A 307—07b Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength R611.5.2.2
A 312/A 312M—08a Specification for Seamless, Welded and Heavily Cold Worked
Austenitic Stainless Steel Pipes
Table P2905.4, Table P2905.5,
Table P2905.6, P2905.12.2
A 463/A 463M—06 Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip Process Table R905.10.3(2)
A 510—08 Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon Steel R606.15
A 539—99 Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines M2202.1
A 615/A 615M—09 Specification for Deformed and Plain Billet-steel Bars for
Concrete Reinforcement
R402.3.1, R404.1.2.3.7.1, R611.5.2.1
A 641/A 641M—09a Specification for Zinc-coated (Galvanized) Carbon Steel Wire Table R606.15.1
A 653/A 653M—08 Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron
Alloy-coated Galvanized) by the Hot-dip Process
R317.3.1, R505.2.1,
R505.2.3, R603.2.1, R603.2.3, Table R606.15.1,
R611.5.2.3, R804.2.1, R804.2.3, Table R905.10.3(1),
Table R905.10.3(2), M1601.1.1
A 706/A 706M—09 Specification for Low-alloy Steel Deformed and Plain Bars for
Concrete Reinforcement
R402.3.1, R404.1.2.3.7.1, R611.5.2.1
A 755/A 755M—03 (2008) Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and
Prepainted by the Coil-coating Process for Exterior Exposed Building Products
Table R905.10.3(2)
A 778—01 Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products Table P2905.4,
Table P2905.5, Table P2905.6
A 792/A 792M—08 Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the
Hot-dip Process
R505.2.1, R505.2.3, R603.2.1,
R603.2.3, R611.5.2. 3, R804.2.1,
R804.2.3, Table 905.10.3(2)
A 875/A 875M—06 Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the
Hot-dip Process
R611.5.2.3, Table R905.10.3(2)
A 888—09 Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain,
Waste and Vent Piping Application
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3005.2.9, Table P3302.1
A 924/A 924M—08a Standard Specification for General Requirements for Steel Sheet, Metallic-coated
by the Hot-Dip Process
Table R905.10.3(1)
A 951—06 Specification for Steel Wire Masonry Joint Reinforcement R606.15
A 996/A 996M—09 Specifications for Rail-steel and Axle-steel Deformed Bars for Concrete Reinforcement Table R404.1.2(9),
R404.1.2.3.7.1,
R611.5.2.1, Table R611.5.4(2)
A 1003/A 1003M—08 Standard Specification for Steel Sheet, Carbon, Metallic and
Nonmetallic-coated for Cold-formed Framing Members
R505.2.1, R505.2.3, R603.2.1,
R603.2.3, R804.2.1, R804.2.3
B 32—08 Specification for Solder Metal P3003.10.3, P3003.11.3
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes Table M2101.1, Table P2905.4,
Table P2905.5, Table P3002.1(1)
B 43—98 (2004) Specification for Seamless Red Brass Pipe, Standard Sizes Table M2101.1, G2413.5.2,
Table P2905.4, Table P3002.1(1)
B 75—02 Specification for Seamless Copper Tube Table M2101.1, Table P2905.4, Table P2905.5,
Table P3002.1(1), Table P3002.1(2), Table P3002.2
B 88—03 Specification for Seamless Copper Water Tube Table M2101.1, G2414.5.2, Table, P2905.4,
Table P2905.5, Table P3002.1(1),
Table P3002.1(2), Table P3002.2
B 101—07 Specification for Lead-coated Copper Sheet and Strip for Building Construction Table R905.2.8.2,
Table R905.10.3(1)
B 135—08a Specification for Seamless Brass Tube Table M2101.1
B 209—07 Specification for Aluminum and Aluminum-alloy Sheet and Plate Table 905.10.3(1)
B 227—04 Specification for Hard-drawn Copper-clad Steel Wire R606.15
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and
Copper-alloy Tube
Table M2101.1, Table P2905.4,
Table P2905.5, Table P3002.1(1), Table P3002.2
B 302—07 Specification for Threadless Copper Pipe, Standard Sizes Table M2101.1, Table P2905.4,
Table P2905.5, Table P3002.1(1)
B 306—09 Specification for Copper Drainage Tube (DWV) Table M2101.1, Table P3002.1(1),
Table P3002.1(2), Table P3002.2
B 370—09 Specification for Copper Sheet and Strip for Building Construction Table R905.2.8.2,
Table R905.10.3(1), Table P2701.1
B 447—07 Specification for Welded Copper Tube Table P2904.4, Table P2905.5
B 695—04 Standard Specification for Coatings of Zinc Mechanically Deposited on
Iron and Steel
R317.3.1, R317.3.3
B 813—00 (2009) Specification for Liquid and Paste Fluxes for Soldering Applications
of Copper and Copper Alloy Tube
Table M2101.1, P2905.14,
P3003.10.3, P3003.11.3
B 828—02 Practice for Making Capillary Joints by Soldering of Copper and
Copper Alloy Tube and Fittings
P2905.14, P3003.10.3, P3003.11.3
C 4—04e01 Specification for Clay Drain Tile and Perforated Clay Drain Tile Table P3302.1
C 5—03 Specification for Quicklime for Structural Purposes R702.2.1
C 14—07 Specification for Non-reinforced Concrete Sewer,
Storm Drain and Culvert Pipe
Table P3002.2
C 22/C 22M—00
(2005e01)
Specification for Gypsum R702.2.1, R702.3.1
C27—98 (2008) Specification for Standard Classification of Fireclay
and High-alumina Refractory Brick
R1001.5, R1001.8
C 28/C 28M—00 (2005) Specification for Gypsum Plasters R702.2.1
C 33/C 33M—08 Specification for Concrete Aggregates R403.4.1
C 34—03 Specification for Structural Clay Load-bearing Wall Tile Table R301.2(1)
C 35—01(2005) Specification for Inorganic Aggregates for Use in Gypsum Plaster R702.2.1
C 55—06e01 Specification for Concrete Building Brick R202, Table R301.2(1)
C 59/C 59M—00 (2006) Specification for Gypsum Casting and Molding Plaster R702.2
C 61/C 61M—00 (2006) Specification for Gypsum Keene's Cement R702.2.1
C 62—08 Specification for Building Brick (Solid Masonry
Units Made from Clay or Shale)
R202, Table R301.2(1)
C 73—05 Specification for Calcium Silicate Face Brick (Sand Lime Brick) R202, Table R301.2(1)
C 76—08a Specification for Reinforced Concrete Culvert, Storm
Drain and Sewer Pipe
Table P3002.2
C 90—08 Specification for Load-bearing Concrete Masonry Units Table R301.2(1)
C 91—05 Specification for Masonry Cement R702.2.2
C 94/C 94M—09 Specification for Ready-mixed Concrete R404.1.2.3.2, R611.5.1.1
C 129—06 Specification for Nonload-bearing Concrete Masonry Units Table R301.2(1)
C 143/C 143M—08 Test Method for Slump or Hydraulic Cement Concrete R404.1.2.3.4, R611.5.1.3, R611.6.1
C 145—85 Specification for Solid Load-bearing Concrete Masonry Units R202, Table R301.2(1)
C 150—07 Specification for Portland Cement R702.2.2
C 199—84 (2005) Test Method for Pier Test for Refractory Mortar R1001.5, R1001.8, R1003.12
C 203—05a Standard Test Methods for Breaking Load and Flexural
Properties of Block-type Thermal Insulation
Table R613.3.1
C 207—06 Specification for Hydrated Lime for Masonry Purposes Table R607.1
C 208—08a Specification for Cellulosic Fiber Insulating Board Table R602.3(1), Table R906.2
C 216—07a Specification for Facing Brick (Solid Masonry Units
Made from Clay or Shale)
R202, Table R301.2(1)
C 270—08a Specification for Mortar for Unit Masonry R607.1, AE602
C 272—01(2007) Standard Test Method for Water Absorption of Core Materials for
Structural Sandwich Constructions
Table R613.3.1
C 273/C 273M—07a Standard Test Method for Shear Properties of Sandwich Core Materials Table R613.3.1
C 296—00 (2004) Specification for Asbestos Cement Pressure Pipe Table P2905.4
C 315—07 Specification for Clay Flue Liners and Chimney Pots R1001.8, R1003.11.1,
Table R1003.14(1), G2425.12
C 406—06e01 Specifications for Roofing Slate R905.6.4
C 411—05 Test Method for Hot-surface Performance of High-temperature Thermal Insulation M1601.3
C 425—04 Specification for Compression Joints for Vitrified Clay Pipe and Fittings Table P3002.2, P3003.15, P3003.18
C 428—05 (2006) Specification for Asbestos-cement Nonpressure Sewer Pipe Table P3002.2
C 443—05a Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets P3003.7, P3003.18
C 475/C 475—02 (2007) Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard R702.3.1
C 476—08 Specification for Grout for Masonry R609.1.1
C 508—04 Specification for Asbestos-cement Underdrain Pipe Table P3302.1
C 514—04 Specification for Nails for the Application of Gypsum Wallboard R702.3.1
C 552—07 Standard Specification for Cellular Glass Thermal Insulation Table R906.2
C 557—03e01 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing R702.3.1
C 564—08 Specification for Rubber Gaskets for Cast Iron Soil Pipe and Fittings P3003.6.2, P3003.6.3, P3003.18
C 578—08b Specification for Rigid, Cellular Polystyrene Thermal Insulation R403.3, R613.3.1,
R703.11.2.1, Table R906.2
C 587—04 Specification for Gypsum Veneer Plaster R702.2.1
C 595—08a Specification for Blended Hydraulic Cements R702.2.2
C 631—09 Specification for Bonding Compounds for Interior Gypsum Plastering R702.2.1
C 645—08a Specification for Nonstructural Steel Framing Members R702.3.3
C 652—09 Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale) R202, Table R301.2(1)
C 685/C 685M—07 Specification for Concrete Made by Volumetric
Batching and Continuous Mixing
R404.1.2.3.2, R611.5.1.1
C 700—07a Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength and Perforated Table P3002.2, Table P3002.3, Table P3302.1
C 728—05 Standard Specification for Perlite Thermal Insulation Board Table R906.2
C 836—06 Specification for High Solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane for Use with Separate Wearing Course
R905.15.2
C 843—99 (2006) Specification for Application of Gypsum Veneer Plaster R702.2.1
C 844—04 Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster R702.2.1
C 847—09 Specification for Metal Lath R702.2.1, R702.2.2
C 887—05 Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar R406.1
C 897—05 Specification for Aggregate for Job-mixed Portland Cement-based Plasters R702.2.2
C 920—08 Standard Specification for Elastomeric Joint Sealants R406.4.1
C 926—06 Specification for Application of Portland Cement-based Plaster R702.2.2, R702.2.2.1, R703.6,
R703.6.2.1, R703.6.4
C 933—07b Specification for Welded Wire Lath R702.2.1, R702.2.2
C 954—07 Specification for Steel Drill Screws for the Application of Gypsum Panel
Products or Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or to 0.112 in. (2.84 mm) in Thickness
R505.2.4, R603.2.4, R702.3.6, R804.2.4
C 955—09 Specification for Load-bearing (Transverse and Axial) Steel Studs, Runners (Tracks), and Bracing or Bridging for Screw Application of Gypsum Panel Products and Metal Plaster Bases R702.3.3
C 957—06 Specification for High-solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane for Use with Integral Wearing Surface
R905.15.2
C 1002—07 Specification for Steel Drill Screws for the Application of Gypsum Panel Products
or Metal Plaster Bases
R702.3.1, R702.3.6
C 1029—08 Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation R905.14.2
C 1032—06 Specification for Woven Wire Plaster Base R702.2.1, R702.2.2
C 1047—09 Specification for Accessories for Gypsum Wallboard
and Gypsum Veneer Base
R702.2.1, R702.2.2, R702.3.1
C 1063—08 Specification for Installation of Lathing and Furring to Receive Interior and
Exterior Portland Cement-based Plaster
R702.2.2, R703.6
C 1107/C 1107M—08 Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink) R402.3.1
C 1116/C 116M—08a Standard Specification for Fiber-reinforced Concrete and Shotcrete R402.3.1
C 1167—03 Specification for Clay Roof Tiles R905.3.4
C 1173—08 Specification for Flexible Transition Couplings for Underground
Piping Systems
P3003.3, P3003.7, P3003.8.1,
P3003.14.1, P3003.15, P3003.17.2, P3003.18
C 1177/C 1177M—08 Specification for Glass Mat Gypsum Substrate for Use as Sheathing R702.3.1
C 1178/C 1178M—08 Specification for Glass Mat Water-resistant Gypsum Backing Panel R702.3.1, R702.3.8, R702.4.2
C 1186—08 Specification for Flat Nonasbestos Fiber Cement Sheets R703.10.1, R703.10.2
C 1261—07 Specification for Firebox Brick for Residential Fireplaces R1001.5, R1001.8
C 1277—08 Specification for Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings P3003.6.3
C 1278/C 1278M—07a Specification for Fiber-reinforced Gypsum Panels R702.3.1, R702.3.8, R702.4.2
C 1283—07a Practice for Installing Clay Flue Lining R1003.9.1, R1003.12
C 1288—99 (2004)e1 Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets R702.4.2
C 1289—08 Standard Specification for Faced Rigid Cellular Polyisocyanurate
Thermal Insulation Board
R703.11.2.1, Table R906.2
C 1325—08b Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate Sheets R702.4.2
C 1328—05 Specification for Plastic (Stucco) Cement R702.2.2
C 1396/C 1396M—06a Specification for Gypsum Board Table R602.3(1), R702.2.1, R702.2.2, R702.3.1, R702.3.8
C 1440—08 Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain,
Waste and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
P3003.18
C 1460—08 Specification for Shielded Transition Couplings for Use with Dissimilar
DWV Pipe and Fittings Above Ground
P3003.18
C 1461—08 Specification for Mechanical Couplings Using Thermoplastic
Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary
and Storm Plumbing Systems for Above and Below Ground Use
P3003.18
C 1492—03 Specification for Concrete Roof Tile R905.3.5
C 1513—04 Standard Specification for Steel Tapping Screws for Cold-formed
Steel Framing Connections
R505.2.4, R603.2.4, R702.3.6, R804.2.4
C 1658/C 1658M—06 Standard Specification for Glass Mat Gypsum Panels R702.3.1
D 41—05 Specification for Asphalt Primer Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2, Table R905.11.2
D 43—00(2006) Specification for Coal Tar Primer Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2
D 225—07 Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules R905.2.4
D 226—06 Specification for Asphalt-saturated (Organic Felt) Used in Roofing and Waterproofing R703.2, R905.2.3,
R905.3.3, R905.4.3, R905.4.3.2,
R905.5.3, R905.5.3.2, R905.6.3,
R905.6.3.2, R905.7.3, R905.8.3, R905.8.3.2,
R905.8.4, Table R905.9.2, R905.10.5.1
D 227—03 Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing Table R905.9.2
D 312—00 (2006) Specification for Asphalt Used in Roofing Table R905.9.2
D 422—63 (2007) Test Method for Particle-size Analysis of Soils R403.1.8.1
D 449—03 (2008) Specification for Asphalt Used in Dampproofing and Waterproofing R406.2
D 450—07 Specification for Coal-tar Pitch Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2
D 1227—95 (2007) Specification for Emulsified Asphalt Used as a Protective
Coating for Roofing
Table R905.9.2, Table R905.11.2, R905.15.2
D 1248—05 Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable M1601.1.2
D 1527—99 (2005) Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe,
Schedules 40 and 80
Table P2905.4
D 1621—04a Standard Test Method for Compressive Properties of Rigid Cellular Plastics Table R613.3.1
D 1622—08 Standard Test Method for Apparent Density of Rigid Cellular Plastics Table R613.3.1
D 1623—03 Standard Test Method for Tensile and Tensile Adhesion
Properties of Rigid Cellular Plastics
Table R613.3.1
D 1693—08 Test Method for Environmental Stress-cracking of Ethylene Plastics Table M2101.1
D 1784—08 Standard Specification for Rigid Poly (Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds
M1601.1.2
D 1785—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe,
Schedules 40, 80 and 120
Table P2905.4
D 1863—05 Specification for Mineral Aggregate Used in Built-up Roofs Table R905.9.2
D 1869—95 (2005)e1 Specification for Rubber Rings for Asbestos-cement Pipe P2904.17, P3003.4, P3003.18
D 1970—09 Specification for Self-adhering Polymer Modified Bitumen
Sheet Materials Used as Steep Roofing Underlayment for
Ice Dam Protection
R905.2.3, R905.2.7.2, R905.2.8.2,
R905.3.3.3, R905.4.3, R905.4.3.2, R905.5.3.2,
R905.6.3.2, R905.7.3.2, R905.8.3.2, R905.10.5.1
D 2104—03 Specification for Polyethylene (PE) Plastic Pipe, Schedule 40 Table P2905.4
D 2126—04 Standard Test Method for Response of Rigid Cellular Plastics
to Thermal and Humid Aging
Table R613.3.1
D 2178—04 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table R905.9.2
D 2235—04 Specification for Solvent Cement for Acrylonitrile-butadiene-styrene
(ABS) Plastic Pipe and Fittings
P2905.9.1.1, P3003.3.2, P3003.8.2
D 2239—03 Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on
Controlled Inside Diameter
Table P2905.4
D 2241—05 Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated
Pipe (SDR-Series)
Table P2905.4
D 2282—05 Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (SDR-PR) Table P2905.4
D 2412—02 (2008) Test Method for Determination of External Loading Characteristics of
Plastic Pipe by Parallel-plate Loading
M1601.1.2
D 2447—03 Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80,
Based on Outside Diameter
Table M2101.1
D 2464—06 Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic
Pipe Fittings, Schedule 80
Table P2905.6
D 2466—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic
Pipe Fittings, Schedule 40
Table P2905.6
D 2467—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic
Pipe Fittings, Schedule 80
Table P2905.6
D 2468—96a Specification for Acrylonitrile-butadiene-styrene (ABS)
Plastic Pipe Fittings, Schedule 40
Table P2905.6
D 2513—08b Specification for Thermoplastic Gas Pressure Pipe,
Tubing and Fittings
Table M2101.1, M2104.2.1.3,
G2414.6, G2414.6.1, G2414.11, G2415.15.2
D 2559—04 Standard Specification for Adhesives for Structural Laminated Wood
Products for Use Under Exterior (West Use) Exposure Conditions
R613.3.3
D 2564—04e01 Specification for Solvent Cements for Poly (Vinyl Chloride)
(PVC) Plastic Piping Systems
P2905.9.1.3, Table P3002.2,
P3003.9.2, P3003.14.2
D 2609—02 (2008) Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe Table P2905.6
D 2626—04 Specification for Asphalt-saturated and Coated Organic Felt Base
Sheet Used in Roofing
R905.3.3, Table R905.9.2
D 2657—07 Standard Practice for Heat Fusion-joining of Polyolefin Pipe Fittings P2905.3.1, P3003.17.1
D 2661—08 Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic
Drain, Waste, and Vent Pipe and Fittings
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.3.2, P3003.8.2
D 2665—09 Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain,
Waste and Vent Pipe and Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3
D 2672—96a (2003) Specification for Joints for IPS PVC Pipe Using Solvent Cement Table P2905.4
D 2683—04 Specification for Socket-type Polyethylene Fittings for Outside
Diameter-controlled Polyethylene Pipe and Tubing
Table M2101.1, M2104.2.1.1
D 2729—03 Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings P3009.14.10, Table P3302.1,
Table AO103.10
D 2737—03 Specification for Polyethylene (PE) Plastic Tubing Table P2905.4
D 2751—05 Specification for Acrylonitrile-butadiene-styrene (ABS) Sewer Pipe and Fittings Table P3002.2,
Table P3002.3
D 2822—05 Specification for Asphalt Roof Cement, Asbestos Containing Table R905.9.2
D 2823—05 Specification for Asphalt Roof Coatings, Asbestos Containing Table R905.9.2
D 2824—06 Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered,
Asbestos Fibered and Fibered without Asbestos
Table R905.9.2, Table R905.11.2
D 2837—08 Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe
Materials or Pressure Design Basis for Thermoplastic Pipe Products
Table M2101.1
D 2846/D 2846M—09 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Hot- and Cold-water Distribution Systems
Table M2101.1, P2904.9.1.2,
Table P2905.4, Table P2905.5, Table P2905.6
D 2855—96 (2002) Standard Practice for Making Solvent-cemented Joints
with Poly (Vinyl Chloride) (PVC) Pipe and Fittings
P3003.9.2, P3003.14.2
D 2898—04 Test Methods for Accelerated Weathering of Fire-retardant-treated
Wood for Fire Testing
R802.1.3.4, R802.1.3.6
D 2949—01a (2008) Specification for 3.25-in. Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain,
Waste and Vent Pipe and Fittings
Table P3002.1(1),
Table P3002.1(2), Table P3002.2, Table P3002.3
D 3019—08 Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered,
Asbestos Fibered and Nonasbestos Fibered
Table R905.9.2, Table R905.11.2
D 3034—08 Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings Table P3002.2,
Table P3002.3
D 3035—08 Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based On
Controlled Outside Diameter
Table M2101.1
D 3161—09 Test Method for Wind Resistance of Asphalt Shingles (Fan Induced Method) R905.2.4.1,Table R905.2.4.1(2), R905.16.3
D 3201—08a Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base Products R802.1.3.7
D 3212—07 Specification for Joints for Drain and Sewer Plastic Pipes
Using Flexible Elastomeric Seals
P3003.3.1, P3003.8.1, P3003.9.1,
P3003.14.1, P3003.17.2
D 3309—96a (2002) Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution System Table M2101.1
D 3311—08 Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns P3002.3
D 3350—08 Specification for Polyethylene Plastic Pipe and Fitting Materials Table M2101.1
D 3462—09 Specification for Asphalt Shingles Made From Glass Felt and
Surfaced with Mineral Granules
R905.2.4
D 3468—99 (2006)e01 Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene
Used in Roofing and Waterproofing
R905.15.2
D 3679—09 Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding Table R703.4, R703.11
D 3737—08 Practice for Establishing Allowable Properties for Structural Glued
Laminated Timber (Glulam)
R502.1.5, R602.1.2, R802.1.4
D 3747—79 (2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table R905.9.2,
Table R905.11.2
D 3909—97b (2004)e1 Specification for Asphalt Roll Roofing (Glass Felt)
Surfaced with Mineral Granules
R905.2.8.2, R905.5.4, Table R905.9.2
D 3957—06 Standard Practices for Establishing Stress Grades for Structural
Members Used in Log Buildings
R502.1.6, R602.1.3, R802.1.5
D 4022—07 Specification for Coal Tar Roof Cement, Asbestos Containing Table R905.9.2
D 4068—01 Specification for Chlorinated Polyethylene (CPE)
Sheeting for Concealed Water Containment Membrane
P2709.2, P2709.2.2
D 4318—05 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils R403.1.8.1
D 4434/D 4434M—09 Specification for Poly (Vinyl Chloride) Sheet Roofing R905.13.2
D 4479—07 Specification for Asphalt Roof Coatings-asbestos-free Table R905.9.2
D 4551—96 (2008)e1 Specification for Poly (Vinyl) Chloride (PVC) Plastic Flexible
Concealed Water-containment Membrane
P2709.2, P2709.2.1
D 4586—07 Specification for Asphalt Roof Cement-asbestos-free Table R905.9.2
D 4601—08 Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table R905.9.2
D 4637—08 Specification for EPDM Sheet Used in Single-ply Roof Membrane R905.12.2
D 4829—08a Test Method for Expansion Index of Soils R403.1.8.1
D 4869—05e01 Specification for Asphalt-saturated (Organic Felt) Underlayment
Used in Steep Slope Roofing
R905.2.3, R905.2.7.2, R905.4.3, R905.4.3.2,
R905.5.3, R905.5.3.2, R905.6.3, R905.6.3.2,
R905.7.3, R905.7.3.2, R905.8.3, R905.8.3.2
D 4897—01 Specification for Asphalt Coated Glass-fiber Venting
Base Sheet Used in Roofing
Table R905.9.2
D 4990—97a (2005)e01 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table R905.9.2
D 5019—07a Specification for Reinforced Nonvulcanized Polymeric
Sheet Used in Roofing Membrane
R905.12.2
D 5055—09 Specification for Establishing and Monitoring Structural
Capacities of Prefabricated Wood I-joists
R502.1.4
D 5456—09 Standard Specification for Evaluation of Structural
Composite Lumber Products
R502.1.8, R602.14, R802.1.6
D 5516—03 Test Method for Evaluating the Flexural Properties of Fire-retardant-treated
Softwood Plywood Exposed to the Elevated Temperatures
R802.1.3.5.1
D 5643—06 Specification for Coal Tar Roof Cement Asbestos-free Table R905.9.2
D 5664—08 Test Methods For Evaluating the Effects of Fire-retardant Treatments and Elevated
Temperatures on Strength Properties of Fire-retardant-treated Lumber
R802.1.3.5.2
D 5665—99a (2006) Specification for Thermoplastic Fabrics Used in Cold-applied
Roofing and Waterproofing
Table R905.9.2
D 5726—98 (2005) Specification for Thermoplastic Fabrics Used in Hot-applied
Roofing and Waterproofing
Table R905.9.2
D 6083—05e01 Specification for Liquid-applied Acrylic Coating Used in Roofing Table R905.9.2, Table R905.11.2,
Table R905.14.3, R905.15.2
D 6162—00a (2008) Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet
Materials Using a Combination of Polyester and Glass Fiber Reinforcements
Table R905.11.2
D 6163—00 (2008) Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet
Materials Using Glass Fiber Reinforcements
Table R905.11.2
D 6164—05e1 Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous
Sheet Materials Using Polyester Reinforcements
Table R905.11.2
D 6222—08 Specification for Atactic Polypropylene (APP) Modified Bituminous
Sheet Materials Using Polyester Reinforcements.
Table R905.11.2
D 6223—02 Specification for Atactic Polypropylene (APP) Modified Bituminous
Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcement
Table R905.11.2
D 6298—05e1 Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS)
Modified Bituminous Sheets with a Factory Applied Metal Surface
Table R905.11.2
D 6305—08 Practice for Calculating Bending Strength Design Adjustment Factors for
Fire-retardant-treated Plywood Roof Sheathing
R802.1.3.5.1
D 6380—03 (2009) Standard Specification for Asphalt Roll Roofing (Organic Felt) R905.2.8.2, R905.3.3,
R905.5.4
D 6694—08 Standard Specification for Liquid-applied Silicone Coating Used in Spray
Polyurethane Foam Roofing Systems
Table R905.14.3, R905.15.2
D 6754—02 Standard Specification for Ketone-ethylene-ester-based Sheet Roofing R905.13.2
D 6757—07 Standard Specification for Inorganic Underlayment for
Use with Steep Slope Roofing Products
R905.2.3, R905.2.7.2
D 6841—08 Standard Practice for Calculating Design Value Treatment Adjustment
Factors for Fire-retardant-treated Lumber
R802.1.3.5.2
D 6878—08e1 Standard Specification for Thermoplastic-polyolefin-based Sheet Roofing R905.13.2
D 6947—07 Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating
Used in Spray Polyurethane Foam Roofing System
Table R905.14.3, R905.15.2
D 7032—08 Standard Specification for Establishing Performance Ratings for Wood-plastic
Composite Deck Boards and Guardrail Systems (Guards or Handrails)
R317.4, R317.4.1, R507.3
D 7158—08d Standard Test Method for Wind Resistance of Sealed Asphalt Shingles
(Uplift Force/Uplift Resistance Method)
R905.2.4.1,
Table R905.2.4.1(1)
E 84—09 Test Method for Surface Burning Characteristics of Building Materials R202, R302.9.3, R302.9.4,
R302.10.1, R302.10.2, R316.3,
R316.4, R316.5.9, R316.5.11,
R802.1.3, M1601.3, M1601.5.2
E 90—04 Test Method for Laboratory Measurement of Airborne
Sound Transmission Loss of Building Partitions and Elements
AK102, AK102.1.1
E 96/E 96M—05 Test Method for Water Vapor Transmission of Materials R202, Table R613.3.1,
M1411.5, M1601.4.5
E 108—07a Test Methods for Fire Tests of Roof Coverings R902.1
E 119—08a Test Methods for Fire Tests of Building Construction and Materials R302.2, R302.3,
R302.4.1, R316.4
E 136—09 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C R202, Table R302.1(1),
Table R302.1(2), R302.11
E 283—04 Test Method for Determining the Rate of Air Leakage Through Exterior
Windows, Curtain Walls and Doors Under Specified Pressure
Differences Across the Specimen
N1102.4.4
E 330—02 Test Method for Structural Performance of Exterior Windows,
Curtain Walls and Doors by Uniform Static Air Pressure Difference
R612.4, R612.5, R703.1.2
E 331—00 (2009) Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain
Walls by Uniform Static Air Pressure Difference
R703.1.1
E 492—09 Specification for Laboratory Measurement of Impact Sound Transmission
through Floor-ceiling Assemblies Using the Tapping Machine
AK103
E 814—08b Test Method for Fire Tests of Through-penetration Firestops R302.4.1.2
E 970—08a Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation
Using a Radiant Heat Energy Source
R302.10.5
E 1509—04 Standard Specification for Room Heaters, Pellet Fuel-burning Type M1410.1
E 1602—03 Guide for Construction of Solid Fuel Burning Masonry Heaters R1002.2
E 1886—05 Test Method for Performance of Exterior Windows, Curtain Walls, Doors
and Storm Shutters Impacted by Missles and Exposed
to Cyclic Pressure Differentials
R301.2.1.2, R612.6.1
E 1996—09 Standard Specification for Performance of Exterior Windows, Curtain
Walls, Doors and Impact Protective Systems Impacted by
Windborne Debris in Hurricanes
R301.2.1.2, R612.6.1
E 2178—03 Standard Test Method for Air Permeance of Building Materials R202
E 2231—04 Standard Practice for Specimen Preparation and Mounting of Pipe and
Duct Insulation Materials to Assess Surface Burning Characteristics
M1601.3
E 2273—03 Standard Test Method for Determining the Drainage Efficiency of Exterior
Insulation and Finish Systems (EIFS) Clad Wall Assemblies
R703.9.2
E 2568—09e1 Standard Specification for PB Exterior Insulation and Finish Systems (EIFS) R703.9.1, R703.9.2
E 2570—07 Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings
Used Under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
R703.9.2.1
E 2634—08 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems R404.1.2.3.6.1, R611.4.4
F 405—05 Specification for Corrugated Polyethylene (PE) Pipe and Fittings Table P3009.14.10, Table P3302.1,
Table AO103.10
F 409—02(2008) Specification for Thermoplastic Accessible and Replaceable Plastic Tube and
Tubular Fittings
Table P2701.1,
P2702.2, P2702.3
F 437—06 Specification for Threaded Chlorinated Poly (Vinyl Chloride)
(CPVC) Plastic Pipe Fittings, Schedule 80
Table P2905.6
F 438—04 Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 40
Table P2905.6
F 439—06 Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
Table P2905.6
F 441/F 441M—02 (2008) Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe, Schedules 40 and 80
Table P2905.4, Table P2905.5
F 442/F 442M—99
(2005)e1
Specification for Chlorinated Poly (Vinyl Chloride)
(CPVC) Plastic Pipe (SDR-PR)
Table P2905.4, Table P2905.5
F 477—08 Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe P2905.17, P3003.18
F 493—04 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride)
(CPVC) Plastic Pipe and Fittings
P2905.9.1.2
F 628—08 Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain,
Waste and Vent Pipe with a Cellular Core
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.3.2, P3003.8.2
F 656—08 Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride)
(PVC) Plastic Pipe and Fittings
P2905.9.1.3,
P3003.9.2, P3003.14.2
F 714—08 Specification for Polyethylene (PE) Plastic Pipe (SDR-PR)
Based on Outside Diameter
Table P3002.2
F 876—08b Specification for Cross-linked Polyethylene (PEX) Tubing Table M2101.1, Table P2905.4,
Table P2905.5
F 877—07 Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and
Cold-water Distribution Systems
Table M2101.1,
Table P2905.4, Table P2905.5, Table P2905.6
F 891—07 Specification for Coextruded Poly (Vinyl Chloride)
(PVC) Plastic Pipe with a Cellular Core
P2905.6, Table P3002.1(1),
Table P3002.1(2), Table P3002.2, Table P3302.1
F 1055—98 (2006) Specification for Electrofusion Type Polyethylene Fittings for Outside
Diameter Controlled Polyethylene Pipe and Tubing
Table M2101.1, M2104.2.1.2
F 1281—07 Specification for Cross-linked Polyethylene/Aluminum/Cross-linked
Polyethylene (PEX-AL-PEX) Pressure Pipe
Table M2101.1, Table P2905.4,
Table P2905.5, Table P2905.6, P2505.11.1
F 1282—06 Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe
Table M2101.1,
Table P2905.4, Table P2905.5,
Table P2905.6, P2905.11.1
F 1346—91 (2003) Performance Specification for Safety Covers and Labeling Requirements for
All Covers for Swimming Pools, Spas and Hot Tubs
AG105.2, AG105.5
F 1412—09 Specification for Polyolefin Pipe and Fittings for Corrosive
Waste Drainage
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.16.1
F 1488—03 Specification for Coextruded Composite Pipe Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3009.14.10, Table AO103.10
F 1554—07a Specification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield Strength R611.5.2.2
F 1667—05 Specification for Driven Fasteners, Nails, Spikes and Staples Table R703.4, R905.2.5
F 1807—08 Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring
for SDR9 Cross-linked Polyethylene (PEX) Tubing
Table M2101.1, Table P2905.6
F 1866—07 Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and
DWV Fabricated Fittings
Table P3002.3
F 1960—09 Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with
Cross-linked Polyethylene (PEX) Tubing
Table M2101.1, Table P2905.6
F 1973—08 Standard Specification for Factory Assembled Anodeless Risers and Transition
Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution Systems
G2415.15.2
F 1974—08 Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and
Cross-linked Polyethylene/Aluminum/Cross-linked
Polyethylene Composite Pressure Pipe
P2505.11.1, Table P2905.6
F 1986—01 (2006) Multilayer Pipe Type 2, Compression Joints for Hot and Cold Drinking Water Systems Table P2905.4,
Table P2905.5, Table P2905.6
F 2080—08 Specification for Cold-expansion Fittings with Metal Compression-sleeves
for Cross-linked Polyethylene (PEX) Pipe
P2905.6
F 2090—08 Specification for Window Fall Prevention Devices—with Emergency
Escape (Egress) Release Mechanisms
R612.2, R612.3
F 2098—08 Standard Specification for Stainless Steel Clamps for SDR9 PEX
Tubing to Metal Insert Fittings
Table M2101.1, Table P2905.6
F 2159—08 Standard Specification for Plastic Insert Fittings Utilizing a
Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing
P2905.6
F 2200—05 Standard Specification for Automated Vehicular Gate Construction AR103.1
F 2262—05 Standard Specification for Cross-linked Polyethylene/Aluminum/Cross-linked
Polyethylene Tubing OD Controlled SDR9
Table P2905.4, Table P2905.5
F 2389—07e1 Standard for Pressure-rated Polypropylene (PP) Piping Systems Table M2101.1,
Table P2905.4, Table P2905.5,
Table P2905.6, P2905.10.1
F 2434—08 Standard Specification for Metal Insert Fittings Utilizing a Copper
Crimp Ring for Polyethylene/Aluminum/Cross-linked
Polyethylene (PEX-AL-PEX) Tubing
Table P2905.6
F 2623—08 Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDRG Tubing Table M2101.1
F 2735—09 Standard Specification for SDR9 Cross-linked Polyethylene (PEX) and
Raised Temperature (PE-RT) Tubing
Table M2101.1, Table P2905.6
F 2769—09 Polyethylene or Raised Temperature (PE-RT) Plastic Hot and
Cold-Water Tubing and Distribution Systems
Table M2101.1, Table P2905.4
AWPA American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
 
Standard
reference
number
Title Referenced
in code
section number
C1—03 All Timber Products—Preservative Treatment by Pressure Processes R902.2
M4—08 Standard for the Care of Preservative-treated Wood Products R317.1.1, R318.1.2
U1—11 USE CATEGORY SYSTEM: User Specification for Treated Wood
Except Section 6 Commodity Specification H
R317.1, R322.1.8, R402.1.2,
R504.3, Table R905.8.5
AWS American Welding Society
550 N. W. LeJeune Road
Miami, FL 33126
 
Standard
reference
number
Title Referenced
in code
section number
A5.8—04 Specifications for Filler Metals for Brazing and Braze Welding P3003.5.1, P3003.10.1, P3003.11.1
AWWA American Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
 
Standard
reference
number
Title Referenced
in code
section number
C104—98 Standard for Cement-mortar Lining for Ductile-iron Pipe and Fittings for Water P2905.4
C110/A21.10—03 Standard for Ductile-iron and Gray-iron Fittings, 3 Inches through 48 Inches, for Water Table P2905.6,
Table P3002.3
C115/A21.15—99 Standard for Flanged Ductile-iron Pipe with Ductile-iron or
Gray-iron Threaded Flanges
Table P2905.4
C151/A21.51—02 Standard for Ductile-iron Pipe, Centrifugally Cast, for Water Table P2905.4
C153/A21.53—00 Standard for Ductile-iron Compact Fittings for Water Service Table P2905.6
C510—00 Double Check Valve Backflow Prevention Assembly Table P2902.3, P2902.3.6
C511—00 Reduced-pressure Principle Backflow Prevention Assembly Table P2902.3,
P2902.3.5, P2902.5.1
C901—08 Polyethylene (PE) Pressure Pipe and Tubing 1/2 in. (13 mm)
through 3 in. (76 mm) for Water Service
P2905.4
C904—06 Cross-Linked Polyethylene (PEX) Pressure Pipe, 1/2 in. (12 mm) through 3 in. (76 mm)
for Water Service
P2905.4
CGSB Canadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
 
Standard
reference
number
Title Referenced
in code
section number
CAN/CGSB-37.54—95 Polyvinyl Chloride Roofing and Waterproofing Membrane R905.13.2
37-GP-52M—(1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric R905.12.2
37-GP-56M—(1980) Membrane, Modified Bituminous, Prefabricated and Reinforced for
Roofing—with December 1985 Amendment
Table R905.11.2
CISPI Cast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga, TN 37421
 
Standard
reference
number
Title Referenced
in code
section number
301—04a Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste and Vent Piping Applications
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3005.2.9, Table P3302.1
310—04 Standard Specification for Coupling for Use in Connection with Hubless
Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain,
Waste and Vent Piping Applications
P3003.6.3
CPA Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
 
Standard
reference
number
Title Referenced
in code
section number
ANSI A135.4—04 Basic Hardboard Table R602.3(2)
ANSI A135.5—04 Prefinished Hardboard Paneling R702.5
ANSI A135.6—06 Hardboard Siding Table R703.4
CPSC Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
 
Standard
reference
number
Title Referenced
in code
section number
16 CFR, Part 1201—(2002) Safety Standard for Architectural Glazing R308.1.1, R308.3.1, Table R308.3.1(1)
16 CFR, Part 1209—(2002) Interim Safety Standard for Cellulose Insulation R302.10.3
16 CFR, Part 1404—(2002) Cellulose Insulation R302.10.3
CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4N 5N6
 
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
N1102.4.3
ANSI/CSA America
FCI—03
Stationary Fuel Cell Power Systems M1903.1
ANSI Z21.56/CSA 4.7—06 Gas-Fired Pool Heaters G2441.1
ASME A112.18.1/
CSA B125.1—2005
Plumbing Supply Fittings P2708.4, P2722.1, P2722.2, P2722.3
ASME A112.18.2/
CSA B125.2—05
Plumbing Waste Fittings Table P2701.1, P2702.2
ASME A112.19.2/
CSA B45.1—08
Ceramic Plumbing Fixtures Table P2701.1, P2711.1, P2712.1
ASME A112.19.1/
CSA B45.2—02
Enameled Cast-Iron and Enameled Steel Plumbing Fixtures Table 2701.1, P2711.1
ASME A112.19.3—2008/
CSA B45.4—2008
Stainless Steel Plumbing Fixtures Table P2701.1, P2705.1, P2711.1, P2712.1
A112.19.5/
CSA B45.15—2009
Trim for Water-closet Bowls, Tanks and Urinals Table P2701.1
CSA 8—93 Requirements for Gas Fired Log Lighters for Wood Burning Fireplaces
with revisions through January 1999
G2433.1
O325—07 Construction Sheathing R503.2.1, R602.3, R604.1, R903.2.1
O437-Series—93 Standards on OSB and Waferboard (Reaffirmed 2006) R503.2.1, R602.3, R604.1, R803.2.1
CAN/CSA A257.1M—92 Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table P3002.2
CAN/CSA A257.2M—92 Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table P3002.2
CAN/CSA A257.3M—92 Joints for Circular Concrete Sewer and Culvert Pipe,
Manhole Sections and Fittings Using Rubber Gaskets
P3003.7, P3003.18
CAN/CSA B64.1.1—01 Vacuum Breakers, Atmospheric Type (AVB) Table P2902.2, P2902.3.2
CAN/CSA B64.2—01 Vacuum Breakers, Hose Connection Type (HCVP) Table P2902.2, P2902.3.2
CAN/CSA B64.2.2—01 Vacuum Breakers, Hose Connection Type (HCVP) with
Automatic Draining Feature
Table P2902.2, P2902.3.2
CAN/CSA B64.3—01 Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP) Table P2902.2, P2902.3.3
CAN/CSA B64.4—01 Backflow Preventers, Reduced Pressure Principle Type (RP) Table P2902.3,
101/I.S.2/A440—08 Specifications for Windows, Doors and Unit Skylights R308.6.9, R612.6
B45.5—02 (R2008) Plastic Plumbing Fixtures Table P2701.1, P2711.2, P2712.1
B45.9—99 (R2008) Macerating Systems and Related Components P3007.1, P3007.2.1, P3007.5
B64.1.2—07 Pressure Vacuum Breakers (PVB) Table P2902.2, P2902.3.4
B64.1.3—07 Spill Resistant Pressure Vacuum Breakers (SRPVB) P2902.3
B64.2.1—07 Hose Connection Vacuum Breakers (HCVB)
with Manual Draining Feature
Table P2902.2, P2902.3.2
B64.2.1.1—07 Hose Connection Dual Check Vacuum Breakers (HCDVB) Table P2902.2, P2902.3.2
B64.3—07 Dual Check Backflow Preventers with Atmospheric Port (DCAP) Table P2902.2
B64.4.1—07 Reduced Pressure Principle for Fire Sprinklers (RPF) Table P2902.2
B64.5—07 Double Check Backflow Preventers (DCVA) Table P2902.2, P2902.3.6
B64.5.1—07 Double Check Valve Backflow Preventers,
Type for Fire Systems (DCVAF)
Table P2902.2, P2902.3.6
B64.6—07 Dual Check Valve Backflow Preventers (DuC Table P2902.3
B64.7—07 Laboratory Faucet Vacuum Breakers (LFVB) Table P2902.2, P2902.3.2
B125.3—05 Plumbing Fittings Table 2701.1, P2713.3, P2721.2
B137.1—05 Polyethylene (PE) Pipe, Tubing and Fittings for
Cold Water Pressure Services
Table P2905.4, Table P2905.6
B137.2—05 Polyvinylchloride PVC Injection-moulded Gasketed Fittings for
Pressure Applications
Table P2905.6
B137.3—05 Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications Table P2905.4, P3003.9.2,
P3003.14.2
B137.5—05 Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications Table P2905.4,
Table P2905.5, Table P2905.6
B137.6—05 Chlorinated polyvinylchloride CPVC Pipe, Tubing and Fittings For Hot- and
Cold-water Distribution Systems
Table P2905.4,
Table P2905.5, Table 2905.6
B137.9—05 Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe Systems
P2505.11.1, Table P2905.4
B137.10M—05 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX)
Composite Pressure Pipe Systems
Table M2101.1, P2505.11.1,
Table P2905.4, Table P2905.5
B137.11—05 Polypropylene (PP-R) Pipe and Fittings for Pressure Applications Table P2905.4.1, Table 2905.4,
Table P2905.6
B181.1—06 Acrylonitrile-butadiene-styrene (ABS) Drain, Waste and Vent Pipe
and Pipe Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3003.3.2, P3003.8.2
B181.2—06 Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC)
Drain, Waste and Vent Pipe and Pipe Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3003.9.2, P3003.14.2,
P3008.2, Table P3302.1
B181.3—06 Polyolefin and polyvinylidene (PVDF) Laboratory Drainage Systems Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.16.1
B182.2—06 PSM Type polyvinylchloride (PVC) Sewer Pipe and Fittings Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, Table P3302.1
B182.4—06 Profile polyvinylchloride (PVC) Sewer Pipe & Fittings Table P3002.2,
Table P3002.3, Table P3302.1
B182.6—06 Profile Polyethylene Sewer Pipe and Fittings Table P3302.1
B182.8—06 Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings Table P3302.1
B356—00 Water Pressure Reducing Valves for Domestic Water Supply Systems P2903.3.1
B483.1—07 Drinking Water Treatment Systems P2908.1, P2908.2
B602—05 Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe P3003.3.1, P3003.6.3,
P3003.7, P3003.8.1, P3003.14.1, P3003.15, P3003.17.2
LC3—00 Appliance Stands and Drain Pans P2801.5
    P2902.3.5, P2902.5.1
CSSB Cedar Shake & Shingle Bureau
P.O. Box 1178
Sumas, WA 98295-1178
 
Standard
reference
number
Title Referenced
in code
section number
CSSB—97 Grading and Packing Rules for Western Red Cedar Shakes and Western
Red Shingles of the Cedar Shake and Shingle Bureau
R702.6, R703.5, Table R905.7.4,
Table R905.8.5
DASMA Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
 
Standard
reference
number
Title Referenced
in code
section number
108—05 Standard Method for Testing Garage Doors: Determination of Structural
Performance Under Uniform Static Air Pressure Difference
R612.4
115—05 Standard Method for Testing Garage Doors: Determination of Structural
Performance Under Missile Impact and Cyclic Wind Pressure
R301.2.1.2
DOC United States Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230
 
Standard
reference
number
Title Referenced
in code
section number
PS 1—09 Structural Plywood R404.2.1, Table R404.2.3, R503.2.1,
R602.3, R604.1, R613.3.2, R803.2.1
PS 2—10 Performance Standard for Wood-based Structural-use Panels R404.2.1, Table R404.2.3,
R503.2.1, R602.3, R604.1, R613.3.2, Table 613.3.2, R803.2.1
PS 20—05 American Softwood Lumber Standard R404.2.1, R502.1, R602.1, R802.1
DOTn Department of Transportation
1200 New Jersey Avenue SE
East Building, 2nd floor
Washington, DC 20590
 
Standard
reference
number
Title Referenced
in code
section number
49 CFR, Parts 192.281(e)
& 192.283 (b) (2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards G2414.6.1
FEMA Federal Emergency Management Agency
500 C Street, SW
Washington, DC 20472
 
Standard
reference
number
Title Referenced
in code
section number
FA/TB-2—08 Flood-damage Resistant Materials Requirements R322.1.8
FEMA-TB-11—01 Crawlspace Construction for Buildings Located in Special Flood Hazard Area R408.7
FM Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P. O. Box 7500
Johnson, RI 02919
 
Standard
reference
number
Title Referenced
in code
section number
4450—(1989) Approval Standard for Class 1 Insulated Steel Deck Roofs—with
Supplements through July 1992
R906.1
4880—(2005) American National Standard for Evaluating Insulated Wall or
Wall and Roof/Ceiling Assemblies, Plastic Interior Finish Materials,
Plastic Exterior Building Panels, Wall/Ceiling Coating Systems,
Interior or Exterior Finish Systems
R316.4, R316.6
GA Gypsum Association
810 First Street, Northeast, Suite 510
Washington, DC 20002-4268
 
Standard
reference
number
Title Referenced
in code
section number
GA-253—07 Application of Gypsum Sheathing Table R602.3(1)
HPVA Hardwood Plywood & Veneer Association
1825 Michael Faraday Drive
Reston, Virginia 20190-5350
 
Standard
reference
number
Title Referenced
in code
section number
ANSI/HP-1—2009 Standard for Hardwood and Decorative Plywood R702.5
HVI Home Ventilating Institute
1000 N. Rand Road, Ste 214
Wauconda, IL 60084
 
Standard
reference
number
Title Referenced
in code
section number
HVI 916—09 Airflow Test Procedure Table M1507.3
ICC International Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
 
Standard
reference
number
Title Referenced
in code
section number
IBC—12 International Building Code® R101.2, R110.2, R301.1, R301.1.3, R301.2.2.1.1,
R301.2.2.1.2, R301.2.2.4, R301.3, R308.5, R320.1, R321.3,
R322.1, R403.1.8, R602.10.3(3), R606.12.2.1, R802.1.3.4,
R905.10.3, N1102.2.10, G2402.3, Table AH107.4(1), AH107.4.3
ICC/ANSI A117.1—09 Accessible and Usable Buildings and Facilities R321.3
ICC 400—12 Standard on the Design and Construction of Log Structures R301.1.1
ICC 500—08 ICC/NSSA Standard on the Design and Construction of Storm Shelters R323.1
ICC 600—08 Standard for Residential Construction in High-wind Regions R301.2.1.1
IECC—12 International Energy Conservation Code® N1101.2
IFC—12 International Fire Code® R102.7, M2201.7, G2402.3, G2412.2, G2423.1
IFGC—12 International Fuel Gas Code® G2401.1, G2423.1
IMC—12 International Mechanical Code® N1103.2.2, N1103.5, G2402.3
IPC—12 International Plumbing Code® Table R301.2(1), R903.4.1, G2402.3, R2601.1, AO102.6
IPMC—12 International Property Maintenance Code® R102.7
IPSDC—12 International Private Sewage Disposal Code® R322.1.7, AI101.1
ISO International Organization for Standardization
1, ch. de la Voie - Creuse
Case postale 56
CH-1211 Geneva 20, Switzerland
 
Standard
reference
number
Title Referenced
in code
section number
15874—2002 Polypropylene Plastic Piping Systems for Hot and Cold Water Installations Table M2101.1
MSS Manufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, Northeast
Vienna, VA 22180
 
Standard
reference
number
Title Referenced
in code
section number
SP-58—93 Pipe Hangers and Supports—Materials, Design and Manufacture G2418.2
NAIMA North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
 
Standard
reference
number
Title Referenced
in code
section number
AH 116—09 Fibrous Glass Duct Construction Standards, Fifth Edition M1601.1.1
NCMA National Concrete Masonry Association
13750 Sunrise Valley Drive
Herndon, VA 20171-4662
 
Standard
reference
number
Title Referenced
in code
section number
TR 68-A—75 Design and Construction of Plain and Reinforced Concrete Masonry and
Basement and Foundation Walls
R404.1.1
NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
 
Standard
reference
number
Title Referenced
in code
section number
13—10 Installation of Sprinkler Systems R302.3
13D—10 Standard for the Installation of Sprinkler Systems in One- and Two-family
Dwellings and Manufactured Homes
R313.2.1,P2904.1,P2904.2,P2904.6.1
31—11 Installation of Oil-burning Equipment M1801.3.1,M1805.3
58—11 Liquefied Petroleum Gas Code G2412.2,G2414.6.2
70—11 National Electrical Code E3401.1,E3401.2,E4301.1, TableE4303.2,E4304.3,E4304.4
72—10 National Fire Alarm Code R314.1,R314.2
82—09 Standard on Incinerators and Waste Linen Handling Systems and Equipment G2427.2.3
85—11 Boiler and Construction Systems Hazards Code G2452.1
211—10 Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances R1002.5,G2427.5.5.1
259—08 Test Method for Potential Heat of Building Materials R316.5.7,R316.5.8
275—09 Standard Method of Fire Tests for the Evaluation of
Thermal Barriers Used Over Foam Plastic Insulation
R316.4
286—11 Standard Methods of Fire Tests for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth
R302.9.4,R316.4,
R316.5.8,R316.6
501—10 Standard on Manufactured Housing R202,AE201
720—09 Standard for the Installation of Carbon Monoxide (CO) Detectors and Warning Equipment R315.2
853—10 Standard for the Installation of Stationary Fuel Cell Power Systems M1903.1
 
NSF NSF International
789 N. Dixboro
Ann Arbor, MI 48105
 
Standard
reference
number
Title Referenced
in code
section number
14—2008e Plastics Piping System Components and Related Materials M1301.4, P2608.3, P2908.3
42—2007ae Drinking Water Treatment Units—Anesthetic Effects P2908.1, P2908.3
44—2007 Residential Cation Exchange Water Softeners P2908.1, P2908.3
53—2007a Drinking Water Treatment Units—Health Effects P2908.1, P2908.3
58—2007 Reverse Osmosis Drinking Water Treatment Systems P2908.2, P2908.3
61—2008 Drinking Water System Components—Health Effects P2608.5, P2722.1, P2903.9.4,
P2905.4, P2905.5, P2905.6, P2907.3
PCA Portland Cement Association
5420 Old Orchard Road
Skokie, IL 60077
 
Standard
reference
number
Title Referenced
in code
section number
100—07 Prescriptive Design of Exterior Concrete Walls for One- and
Two-family Dwellings (Pub. No. EB241)
R301.2.2.2.4, R301.2.2.3.4, R404.1.2,
R404.1.2.2.1, R404.1.2.2.2, R404.1.2.4, R404.1.4.2,
R611.1, R611.2, R611.9.2, R611.9.3
SBCA Structural Building Components Association
6300 Enterprise Lane
Madison, WI 53719
 
Standard
reference
number
Title Referenced
in code
section number
BCSI—2008 Building Component Safety Information Guide to Good Practice for Handling,
Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses
502.11.2, 802.10.3
CFS-BCSI—2008 Guide to Good Practice for Handling, Installing & Bracing of Cold-formed Steel Trusses 505.1.3, 804.3.7
SMACNA Sheet Metal & Air Conditioning Contractors National Assoc. Inc.
4021 Lafayette Center Road
Chantilly, VA 22021
 
Standard
reference
number
Title Referenced
in code
section number
SMACNA—10 Fibrous Glass Duct Construction Standards (2003) M1601.1.1, M1601.4.1
HVAC Duct Construction Standards Metal and Flexible (2005) M1601.4.1
SMACNA/ANSI-2005 HVAC Duct Construction Standards—Metal and Flexible (2005) M1601.4.1
TMS The Masonry Society
3970 Broadway, Suite 201-D
Boulder, CO 80304
 
Standard
reference
number
Title Referenced
in code
section number
302—07 Standard Method for Determining the Sound Transmission
Class Rating for Masonry Walls
AK102.1.1
402—11 Building Code Requirements for Masonry Structures R404.1.1, R606.1, R606.1.1,
R606.12.1, R606.12.2.3.1,
R606.12.3.2, Table R703.4
403—10 Direct Design Handbook for Masonry Structures R606.1, R606.1.1, R606.12.1,
R606.12.3.1
602—11 Specification for Masonry Structures R404.1.1, R606.12.3.1,
Table R703.4
TPI Truss Plate Institute
583 D'Onofrio Drive, Suite 200
Madison, WI 53719
 
Standard
reference
number
Title Referenced
in code
section number
TPI 1—2007 National Design Standard for Metal-plate-connected
Wood Truss Construction
R502.11.1, R802.10.2
UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062
 
Standard
reference
number
Title Referenced
in code
section number
17—2008 Vent or Chimney Connector Dampers for Oil-fired Appliances M1802.2.2
55A—04 Materials for Built-up Roof Coverings R905.9.2
58—96 Steel Underground Tanks for Flammable and Combustible Liquids—
with Revisions through July 1998
M2201.1
80—07 Steel Tanks for Oil-burner Fuel M2201.1
103—01 Factory-built Chimneys for Residential Type and Building Heating
Appliances—with revisions through March 2010
R202, R1005.3, G2430.1
127—08 Factory-built Fireplaces—with revisions through January 2010 R1001.11, R1004.1,
R1004.4, R1005.4, G2445.7,
174—04 Household Electric Storage Tank Water Heaters
with revisions through November 2005
M2005.1
180—03 Liquid-level Indicating Gauges for Oil Burner Fuels—with revision through March 2007 M2201.5
181—05 Factory-made Air Ducts and Air Connectors—with revisions through May 2003 M1601.2, M1601.4.1
181A—05 Closure Systems for Use with Rigid Air Ducts and Air Connectors—
with revisions through December 1998
M1601.2, M1601.4.1
181B—05 Closure Systems for Use with Flexible Air Ducts and Air Connectors—
with revisions through August 2003
M1601.2, M1601.4.1
217—06 Single- and Multiple-station Smoke Alarms—with revisions through April 2010 R314.1
263—03 Standards for Fire Test of Building Construction and Materials—
with revisions through October 2007
Table R302.1(2), R302.2, R302.3, R302.4.1, R316.4
325—02 Door, Drapery, Gate, Louver and Window Operations and Systems—
with revisions through February 2010
R309.4
343—97 Pumps for Oil-burning Appliances—with revisions through May 2002 M2204.1
378—06 Draft Equipment M1804.2.6
441—10 Gas Vents G2426.1
508—99 Industrial Control Equipment—with revisions through April 2010 M1411.3.1
536—97 Flexible Metallic Hose—with revisions through June 2003 M2202.3
641—95 Type L, Low-temperature Venting Systems
with revisions through July 2009
R202, R1003.11.5, M1804.2.4, G2426.1
651—05 Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings—
with revisions through March 2010
G2414.6.3
723—2008 Standard for Test for Surface Burning Characteristics of
Building Materials
R302.9.3, R302.9.4, R302.10.1, R302.10.2,
R316.3, R316.5.9, R316.5.10, R316.6, R802.1.3, M1601.3
726—95 Oil-fired Boiler Assemblies—with revisions through April 2010 M2001.1.1, M2006.1
727—06 Oil-fired Central Furnaces—with revisions through April 2010 M1402.1
729—03 Oil-fired Floor Furnaces—with revisions through April 2010 M1408.1
730—03 Oil-fired Wall Furnaces—with revisions through April 2010 M1409.1
732—95 Oil-fired Storage Tank Water Heaters—with revisions through April 2010 M2005.1
737—07 Fireplaces Stoves M1414.1, M1901.2
790—04 Standard Test Methods for Fire Tests of Roof Coverings—with revisions through October 2008 R902.1
795—06 Commercial-industrial Gas Heating Equipment
with revisions through April 2010
G2442.1, G2452.1
834—04 Heating, Water Supply and Power Boilers—Electric—with revisions
through December 2009
M2001.1.1
842—07 Valves for Flammable Fluids M2204.2
858—05 Household Electric Ranges—with revisions through November 2007 M1901.2
875—09 Electric Dry-bath Heaters M1902.2
896—93 Oil-burning Stoves—with revisions through May 2010 M1410.1
923—08 Microwave Cooking Appliances—with revisions through June 2010 M1504.1
959—01 Medium Heat Appliance Factory-built Chimneys
with revisions through June 2010
R1005.6
1026—07 Electric Household Cooking and Food Serving Appliances M1901.2
1040—96 Fire Test of Insulated Wall Construction—with revisions through June 2001 R316.4, R316.6
1042—94 Electric Baseboard Heating Equipment—with revisions through February 2008 M1405.1
1256—02 Fire Test of Roof Deck Construction—with revisions through January 2007 R906.1
1261—01 Electric Water Heaters for Pools and Tubs—with revisions through June 2004 M2006.1
1453—04 Electronic Booster and Commercial Storage Tank Water Heaters
with revisions through December 2009
M2005.1
1479—03 Fire Tests of Through-Penetration Firestops—with revisions through March 2010 R302.4.1.2
1482—10 Solid-Fuel-type Room Heaters R1002.2, R1002.5, M1410.1
1618—09 Wall Protectors, Floor Protectors, and Hearth Extensions M1004.2
1673—96 Electric Space Heating Cables—with Revisions through July 2003 M1406.1
1693—02 Electric Radiant Heating Panels and Heating Panel Sets M1406.1
1703—02 Flat-plate Photovoltaic Modules and Panels—with Revisions through April 2008 M2302.3
1741—99 Inverters, Converters, Controllers and Interconnection System Equipment with
Distributed Energy Resources—with Revisions through November 2005
M2302.4
1715—97 Fire Test of Interior Finish Material—with Revisions through March 2004 R316.6
1738—06 Venting Systems for Gas-burning Appliances, Categories II, III and IV G2426.1
1741—99 Inverters, Converters, Controllers and Interconnection System Equipment
for use with Distributed Energy Resources—with Revisions through November 2005
M2302.4
1777—04 Chimney Liners with Revisions through June 2009 R1003.11.1, R1003.18,
G2425.12, G2425.15.4, M1801.3.4,
1995—05 Heating and Cooling Equipment—with Revisions through July 2009 M1402.1, M1403.1,
M1407.1, M1412.1, M1413.1
1996—04 Electric Duct Heaters—with Revisions through December 2006 M1402.1
2017—08 Standard for General-purpose Signaling Devices and Systems—
with Revisions through October 2009
AG105.2
2523—03 Outline of Investigation for Sealed Fuel-fired Water Heaters and Boilers M2001.1.1
2034—08 Standard for Single- and Multiple-station Carbon Monoxide Alarms R315.4
2075—04 Standard for Gas and Vapor Detectors and Sensors—with Revisions
through September 28, 2007
R315.2
2158A—06 Outline of Investigation for Clothes Dryer Transition Duct M1502.4.3
ULC Underwriters' Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada M1R 3B4
 
Standard
reference
number
Title Referenced
in code
section number
CAN/ULC S 102—1988 Standard Methods for Test for Surface Burning Characteristics of Building Materials and
Assemblies—with 2000 revisions
R302.10.2
  United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
 
Standard
reference
number
Title Referenced
in code
section number
CFR Title 16
(May 31, 2005)
R-value Rule 303.1.4
WDMA Window & Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
 
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S2/A440—11

Specifications for Windows, Doors and Skylights
R308.6.9, R612.3, N1102.4.3
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING