Chapter 10 Portable Residential Spas and Portable Residential Exercise Spas

AMENDMENT
This section has been amended at the state or city level. Amendments are shown in green text.
This chapter shall govern the installation, alteration and repair of portable residential spas and portable exercise spas intended for residential use.
In addition to the requirements of this chapter, portable residential spas and portable residential exercise spas shall also comply with the requirements of Chapter 3.
Equipment and appliances shall be listed and labeled, and installed as required by the terms of their approval, in accordance with the conditions of the listing, the manufacturer's instructions and this code. Manufacturer's instructions shall be available on the job site at the time of inspection.
Factory-built portable spas and portable exercise spas installed in residential applications shall be listed and labeled in compliance with UL 1563 or CSA C22.2 No. 218.1.
Spa equipment shall be supported to prevent damage from misalignment and settling in accordance with the manufacturer's instructions.
Electrical components that require placement or servicing shall be accessible.
Instructions and safety signage shall comply with UL 1563 or CSA C22.2 No. 218.1, the manufacturer's recommendations, and the requirements of the local jurisdiction.
Resources
Help us
keep law free
тип