ADOPTS WITH AMENDMENTS:

International Fire Code 2012 (IFC 2012)

Heads up: There are no amended sections in this chapter.

Part 1 — General Provisions

These regulations shall be known as the Fire Code of [NAME OF JURISDICTION], hereinafter referred to as "this code."
This code establishes regulations affecting or relating to structures, processes, premises and safeguards regarding:
  1. The hazard of fire and explosion arising from the storage, handling or use of structures, materials or devices;
  2. Conditions hazardous to life, property or public welfare in the occupancy of structures or premises;
  3. Fire hazards in the structure or on the premises from occupancy or operation;
  4. Matters related to the construction, extension, repair, alteration or removal of fire suppression or alarm systems; and
  5. Conditions affecting the safety of fire fighters and emergency responders during emergency operations.
Provisions in the appendices shall not apply unless specifically adopted.
The purpose of this code is to establish the minimum requirements consistent with nationally recognized good practice for providing a reasonable level of life safety and property protection from the hazards of fire, explosion or dangerous conditions in new and existing buildings, structures and premises, and to provide safety to fire fighters and emergency responders during emergency operations.
If a section, subsection, sentence, clause or phrase of this code is, for any reason, held to be unconstitutional, such decision shall not affect the validity of the remaining portions of this code.
In the event any part or provision of this code is held to be illegal or void, this shall not have the effect of making void or illegal any of the other parts or provisions hereof, which are determined to be legal; and it shall be presumed that this code would have been adopted without such illegal or invalid parts or provisions.
The construction and design provisions of this code shall apply to:
  1. Structures, facilities and conditions arising after the adoption of this code.
  2. Existing structures, facilities and conditions not legally in existence at the time of adoption of this code.
  3. Existing structures, facilities and conditions when required in Chapter 11.
  4. Existing structures, facilities and conditions which, in the opinion of the fire code official, constitute a distinct hazard to life or property.
The administrative, operational and maintenance provisions of this code shall apply to:
  1. Conditions and operations arising after the adoption of this code.
  2. Existing conditions and operations.
No change shall be made in the use or occupancy of any structure that would place the structure in a different division of the same group or occupancy or in a different group of occupancies, unless such structure is made to comply with the requirements of this code and the International Building Code. Subject to the approval of the fire code official, the use or occupancy of an existing structure shall be allowed to be changed and the structure is allowed to be occupied for purposes in other groups without conforming to all of the requirements of this code and the International Building Code for those groups, provided the new or proposed use is less hazardous, based on life and fire risk, than the existing use.
The design and construction of new structures shall comply with the International Building Code, and any alterations, additions, changes in use or changes in structures required by this code, which are within the scope of the International Building Code, shall be made in accordance therewith.
Where structures are designed and constructed in accordance with the International Residential Code, the provisions of this code shall apply as follows:
  1. Construction and design provisions: Provisions of this code pertaining to the exterior of the structure shall apply including, but not limited to, premises identification, fire apparatus access and water supplies. Where interior or exterior systems or devices are installed, construction permits required by Section 105.7 of this code shall also apply.
  2. Administrative, operational and maintenance provisions: All such provisions of this code shall apply.
The provisions of this code relating to the construction, alteration, repair, enlargement, restoration, relocation or moving of buildings or structures shall not be mandatory for existing buildings or structures identified and classified by the state or local jurisdiction as historic buildings when such buildings or structures do not constitute a distinct hazard to life or property. Fire protection in designated historic buildings and structures shall be provided in accordance with an approved fire protection plan.
The codes and standards referenced in this code shall be those that are listed in Chapter 80, and such codes and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.7.1 and 102.7.2.
Where conflicts occur between provisions of this code and referenced codes and standards, the provisions of this code shall apply.
Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of this code, the provisions of this code, as applicable, shall take precedence over the provisions in the referenced code or standard.
Where no applicable standards or requirements are set forth in this code, or are contained within other laws, codes, regulations, ordinances or bylaws adopted by the jurisdiction, compliance with applicable standards of the National Fire Protection Association or other nationally recognized fire safety standards, as approved, shall be deemed as prima facie evidence of compliance with the intent of this code. Nothing herein shall derogate from the authority of the fire code official to determine compliance with codes or standards for those activities or installations within the fire code official's jurisdiction or responsibility.
Requirements that are essential for the public safety of an existing or proposed activity, building or structure, or for the safety of the occupants thereof, which are not specifically provided for by this code, shall be determined by the fire code official.
Where there is a conflict between a general requirement and a specific requirement, the specific requirement shall be applicable. Where, in a specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern.
The provisions of this code shall not be deemed to nullify any provisions of local, state or federal law.
References to chapter or section numbers, or to provisions not specifically identified by number, shall be construed to refer to such chapter, section or provision of this code.

Part 2 — Administrative Provisions

The department of fire prevention is established within the jurisdiction under the direction of the fire code official. The function of the department shall be the implementation, administration and enforcement of the provisions of this code.
The fire code official shall be appointed by the chief appointing authority of the jurisdiction; and the fire code official shall not be removed from office except for cause and after full opportunity to be heard on specific and relevant charges by and before the appointing authority.
In accordance with the prescribed procedures of this jurisdiction and with the concurrence of the appointing authority, the fire code official shall have the authority to appoint a deputy fire code official, other related technical officers, inspectors and other employees.
The fire code official, member of the board of appeals, officer or employee charged with the enforcement of this code, while acting for the jurisdiction, in good faith and without malice in the discharge of the duties required by this code or other pertinent law or ordinance, shall not thereby be rendered liable personally, and is hereby relieved from all personal liability for any damage accruing to persons or property as a result of an act or by reason of an act or omission in the discharge of official duties.
Any suit instituted against any officer or employee because of an act performed by that officer or employee in the lawful discharge of duties and under the provisions of this code shall be defended by the legal representative of the jurisdiction until the final termination of the proceedings. The fire code official or any subordinate shall not be liable for costs in an action, suit or proceeding that is instituted in pursuance of the provisions of this code; and any officer of the department of fire prevention, acting in good faith and without malice, shall be free from liability for acts performed under any of its provisions or by reason of any act or omission in the performance of official duties in connection therewith.
The fire code official is hereby authorized to enforce the provisions of this code and shall have the authority to render interpretations of this code, and to adopt policies, procedures, rules and regulations in order to clarify the application of its provisions. Such interpretations, policies, procedures, rules and regulations shall be in compliance with the intent and purpose of this code and shall not have the effect of waiving requirements specifically provided for in this code.

[A] 104.2 Applications and Permits

AMENDMENT
This section has been amended at the state or city level.
Whenever it is necessary to make an inspection to enforce the provisions of this code, or whenever the fire code official has reasonable cause to believe that there exists in a building or upon any premises any conditions or violations of this code which make the building or premises unsafe, dangerous or hazardous, the fire code official shall have the authority to enter the building or premises at all reasonable times to inspect or to perform the duties imposed upon the fire code official by this code. If such building or premises is occupied, the fire code official shall present credentials to the occupant and request entry. If such building or premises is unoccupied, the fire code official shall first make a reasonable effort to locate the owner or other person having charge or control of the building or premises and request entry. If entry is refused, the fire code official has recourse to every remedy provided by law to secure entry.
When the fire code official has first obtained a proper inspection warrant or other remedy provided by law to secure entry, an owner or occupant or person having charge, care or control of the building or premises shall not fail or neglect, after proper request is made as herein provided, to permit entry therein by the fire code official for the purpose of inspection and examination pursuant to this code.
The fire code official shall carry proper identification when inspecting structures or premises in the performance of duties under this code.
The fire code official is authorized to issue such notices or orders as are required to affect compliance with this code in accordance with Sections 109.1 and 109.2.
The fire code official shall keep official records as required by Sections 104.6.1 through 104.6.4. Such official records shall be retained for not less than five years or for as long as the structure or activity to which such records relate remains in existence, unless otherwise provided by other regulations.
A record of approvals shall be maintained by the fire code official and shall be available for public inspection during business hours in accordance with applicable laws.
The fire code official shall keep a record of each inspection made, including notices and orders issued, showing the findings and disposition of each.
The fire department shall keep a record of fires occurring within its jurisdiction and of facts concerning the same, including statistics as to the extent of such fires and the damage caused thereby, together with other information as required by the fire code official.
Application for modification, alternative methods or materials and the final decision of the fire code official shall be in writing and shall be officially recorded in the permanent records of the fire code official.
All materials, equipment and devices approved by the fire code official shall be constructed and installed in accordance with such approval.
Materials, equipment and devices shall not be reused or reinstalled unless such elements have been reconditioned, tested and placed in good and proper working condition and approved.
To determine the acceptability of technologies, processes, products, facilities, materials and uses attending the design, operation or use of a building or premises subject to inspection by the fire code official, the fire code official is authorized to require the owner or agent to provide, without charge to the jurisdiction, a technical opinion and report. The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire safety specialty organization acceptable to the fire code official and shall analyze the fire safety properties of the design, operation or use of the building or premises and the facilities and appurtenances situated thereon, to recommend necessary changes. The fire code official is authorized to require design submittals to be prepared by, and bear the stamp of, a registered design professional.
Whenever there are practical difficulties involved in carrying out the provisions of this code, the fire code official shall have the authority to grant modifications for individual cases, provided the fire code official shall first find that special individual reason makes the strict letter of this code impractical and the modification is in compliance with the intent and purpose of this code and that such modification does not lessen health, life and fire safety requirements. The details of action granting modifications shall be recorded and entered in the files of the department of fire prevention.
The provisions of this code are not intended to prevent the installation of any material or to prohibit any method of construction not specifically prescribed by this code, provided that any such alternative has been approved. The fire code official is authorized to approve an alternative material or method of construction where the fire code official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety.
Supporting data, when necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources.
Whenever there is insufficient evidence of compliance with the provisions of this code, or evidence that a material or method does not conform to the requirements of this code, or in order to substantiate claims for alternative materials or methods, the fire code official shall have the authority to require tests as evidence of compliance to be made at no expense to the jurisdiction. Test methods shall be as specified in this code or by other recognized test standards. In the absence of recognized and accepted test methods, the fire code official shall approve the testing procedures. Tests shall be performed by an approved agency. Reports of such tests shall be retained by the fire code official for the period required for retention of public records.
The fire code official, the fire department or other responsible authority shall have the authority to investigate the cause, origin and circumstances of any fire, explosion or other hazardous condition. Information that could be related to trade secrets or processes shall not be made part of the public record, except as directed by a court of law.
Police and other enforcement agencies shall have authority to render necessary assistance in the investigation of fires when requested to do so.
The fire chief or officer of the fire department in charge at the scene of a fire or other emergency involving the protection of life or property, or any part thereof, shall have the authority to direct such operation as necessary to extinguish or control any fire, perform any rescue operation, investigate the existence of suspected or reported fires, gas leaks or other hazardous conditions or situations, or take any other action necessary in the reasonable performance of duty. In the exercise of such power, the fire chief is authorized to prohibit any person, vehicle, vessel or thing from approaching the scene, and is authorized to remove, or cause to be removed or kept away from the scene, any vehicle, vessel or thing which could impede or interfere with the operations of the fire department and, in the judgment of the fire chief, any person not actually and usefully employed in the extinguishing of such fire or in the preservation of property in the vicinity thereof.
The fire chief or officer of the fire department in charge at the scene of an emergency is authorized to place ropes, guards, barricades or other obstructions across any street, alley, place or private property in the vicinity of such operation so as to prevent accidents or interference with the lawful efforts of the fire department to manage and control the situation and to handle fire apparatus.
No person shall obstruct the operations of the fire department in connection with extinguishment or control of any fire, or actions relative to other emergencies, or disobey any lawful command of the fire chief or officer of the fire department in charge of the emergency, or any part thereof, or any lawful order of a police officer assisting the fire department.
No person shall render a system or device inoperative during an emergency unless by direction of the fire chief or fire department official in charge of the incident.

Section 105 Permits

AMENDMENT
This section has been amended at the state or city level.

[A] 105.1 General

AMENDMENT
This section has been amended at the state or city level.

[A] 105.1.1 Permits Required

AMENDMENT
This section has been amended at the state or city level.

[A] 105.1.2 Types of Permits

AMENDMENT
This section has been amended at the state or city level.

[A] 105.1.3 Multiple Permits for the Same Location

AMENDMENT
This section has been amended at the state or city level.

[A] 105.2 Application

AMENDMENT
This section has been amended at the state or city level.

[A] 105.2.1 Refusal to Issue Permit

AMENDMENT
This section has been amended at the state or city level.

[A] 105.2.2 Inspection Authorized

AMENDMENT
This section has been amended at the state or city level.

[A] 105.2.3 Time Limitation of Application

AMENDMENT
This section has been amended at the state or city level.

[A] 105.2.4 Action on Application

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3 Conditions of a Permit

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3.1 Expiration

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3.2 Extensions

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3.3 Occupancy Prohibited Before Approval

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3.4 Conditional Permits

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3.5 Posting the Permit

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3.6 Compliance With Code

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3.7 Information on the Permit

AMENDMENT
This section has been amended at the state or city level.

[A] 105.3.8 Validity of Permit

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4 Construction Documents

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.1 Submittals

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.1.1 Examination of Documents

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.2 Information on Construction Documents

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.2.1 Fire Protection System Shop Drawings

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.3 Applicant Responsibility

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.4 Approved Documents

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.4.1 Phased Approval

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.5 Corrected Documents

AMENDMENT
This section has been amended at the state or city level.

[A] 105.4.6 Retention of Construction Documents

AMENDMENT
This section has been amended at the state or city level.

[A] 105.5 Revocation

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6 Required Operational Permits

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.1 Aerosol Products

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.2 Amusement Buildings

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.3 Aviation Facilities

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.4 Carnivals and Fairs

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.5 Cellulose Nitrate Film

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.6 Combustible Dust-Producing Operations

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.7 Combustible Fibers

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.8 Compressed Gases

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.9 Covered and Open Mall Buildings

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.10 Cryogenic Fluids

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.11 Cutting and Welding

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.12 Dry Cleaning

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.13 Exhibits and Trade Shows

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.14 Explosives

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.15 Fire Hydrants and Valves

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.16 Flammable and Combustible Liquids

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.17 Floor Finishing

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.18 Fruit and Crop Ripening

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.19 Fumigation and Insecticidal Fogging

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.20 Hazardous Materials

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.21 HPM Facilities

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.22 High-Piled Storage

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.23 Hot Work Operations

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.24 Industrial Ovens

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.25 Lumber Yards and Woodworking Plants

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.26 Liquid- or Gas-Fueled Vehicles or Equipment in Assembly Buildings

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.27 LP-gas

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.28 Magnesium

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.29 Miscellaneous Combustible Storage

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.30 Open Burning

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.31 Open Flames and Torches

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.32 Open Flames and Candles

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.33 Organic Coatings

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.34 Places of Assembly

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.35 Private Fire Hydrants

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.36 Pyrotechnic Special Effects Material

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.37 Pyroxylin Plastics

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.38 Refrigeration Equipment

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.39 Repair Garages and Motor Fuel-Dispensing Facilities

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.40 Rooftop Heliports

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.41 Spraying or Dipping

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.42 Storage of Scrap Tires and Tire Byproducts

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.43 Temporary Membrane Structures and Tents

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.44 Tire-Rebuilding Plants

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.45 Waste Handling

AMENDMENT
This section has been amended at the state or city level.

[A] 105.6.46 Wood Products

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7 Required Construction Permits

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.1 Automatic Fire-Extinguishing Systems

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.2 Battery Systems

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.3 Compressed Gases

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.4 Cryogenic Fluids

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.5 Emergency Responder Radio Coverage System

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.6 Fire Alarm and Detection Systems and Related Equipment

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.7 Fire Pumps and Related Equipment

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.8 Flammable and Combustible Liquids

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.9 Hazardous Materials

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.10 Industrial Ovens

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.11 LP-gas

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.12 Private Fire Hydrants

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.13 Solar Photovoltaic Power Systems

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.14 Spraying or Dipping

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.15 Standpipe Systems

AMENDMENT
This section has been amended at the state or city level.

[A] 105.7.16 Temporary Membrane Structures and Tents

AMENDMENT
This section has been amended at the state or city level.
The fire code official is authorized to enter and examine any building, structure, marine vessel, vehicle or premises in accordance with Section 104.3 for the purpose of enforcing this code.
The fire code official is authorized to conduct such inspections as are deemed necessary to determine the extent of compliance with the provisions of this code and to approve reports of inspection by approved agencies or individuals. All reports of such inspections shall be prepared and submitted in writing for review and approval. Inspection reports shall be certified by a responsible officer of such approved agency or by the responsible individual. The fire code official is authorized to engage such expert opinion as deemed necessary to report upon unusual, detailed or complex technical issues subject to the approval of the governing body.
It shall be the duty of the holder of the permit or their duly authorized agent to notify the fire code official when work is ready for inspection. It shall be the duty of the permit holder to provide access to and means for inspections of such work that are required by this code.
Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the fire code official. The fire code official, upon notification, shall make the requested inspections and shall either indicate the portion of the construction that is satisfactory as completed, or notify the permit holder or his or her agent wherein the same fails to comply with this code. Any portions that do not comply shall be corrected, and such portion shall not be covered or concealed until authorized by the fire code official.
It shall be the duty of the permit applicant to cause the work to remain accessible and exposed for inspection purposes. Whenever any installation subject to inspection prior to use is covered or concealed without having first been inspected, the fire code official shall have the authority to require that such work be exposed for inspection. Neither the fire code official nor the jurisdiction shall be liable for expense entailed in the removal or replacement of any material required to allow inspection.
Approval as the result of an inspection shall not be construed to be an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Inspections presuming to give authority to violate or cancel provisions of this code or of other ordinances of the jurisdiction shall not be valid.
Whenever or wherever any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance with the provisions of this code, or otherwise installed, such device, equipment, system, condition, arrangement, level of protection, or other feature shall thereafter be continuously maintained in accordance with this code and applicable referenced standards.
Equipment requiring periodic testing or operation to ensure maintenance shall be tested or operated as specified in this code.
Required test and inspection records shall be available to the fire code official at all times or such records as the fire code official designates shall be filed with the fire code official.
Where any work or installation does not pass an initial test or inspection, the necessary corrections shall be made so as to achieve compliance with this code. The work or installation shall then be resubmitted to the fire code official for inspection and testing.
Maintenance and testing shall be under the supervision of a responsible person who shall ensure that such maintenance and testing are conducted at specified intervals in accordance with this code.
Portable or fixed fire-extinguishing systems or devices, and fire-warning systems, shall not be rendered inoperative or inaccessible, except as necessary during emergencies, maintenance, repairs, alterations, drills or prescribed testing.
Overcrowding or admittance of any person beyond the approved capacity of a building or a portion thereof shall not be allowed. The fire code official, upon finding any overcrowding conditions or obstructions in aisles, passageways or other means of egress, or upon finding any condition which constitutes a life safety hazard, shall be authorized to cause the event to be stopped until such condition or obstruction is corrected.

Section 108 Board of Appeals

AMENDMENT
This section has been amended at the state or city level.

[A] 108.1 Board of Appeals Established

AMENDMENT
This section has been amended at the state or city level.

[A] 108.2 Limitations on Authority

AMENDMENT
This section has been amended at the state or city level.

[A] 108.3 Qualifications

AMENDMENT
This section has been amended at the state or city level.
It shall be unlawful for a person, firm or corporation to erect, construct, alter, repair, remove, demolish or utilize a building, occupancy, premises or system regulated by this code, or cause same to be done, in conflict with or in violation of any of the provisions of this code.
Correction and abatement of violations of this code shall be the responsibility of the owner. If an occupant creates, or allows to be created, hazardous conditions in violation of this code, the occupant shall be held responsible for the abatement of such hazardous conditions.
When the fire code official finds a building, premises, vehicle, storage facility or outdoor area that is in violation of this code, the fire code official is authorized to prepare a written notice of violation describing the conditions deemed unsafe and, when compliance is not immediate, specifying a time for reinspection.
A notice of violation issued pursuant to this code shall be served upon the owner, operator, occupant or other person responsible for the condition or violation, either by personal service, mail or by delivering the same to, and leaving it with, some person of responsibility upon the premises. For unattended or abandoned locations, a copy of such notice of violation shall be posted on the premises in a conspicuous place at or near the entrance to such premises and the notice of violation shall be mailed by certified mail with return receipt requested or a certificate of mailing, to the last known address of the owner, occupant or both.
A notice of violation issued or served as provided by this code shall be complied with by the owner, operator, occupant or other person responsible for the condition or violation to which the notice of violation pertains.
If the notice of violation is not complied with promptly, the fire code official is authorized to request the legal counsel of the jurisdiction to institute the appropriate legal proceedings at law or in equity to restrain, correct or abate such violation or to require removal or termination of the unlawful occupancy of the structure in violation of the provisions of this code or of the order or direction made pursuant hereto.
Signs, tags or seals posted or affixed by the fire code official shall not be mutilated, destroyed or tampered with, or removed, without authorization from the fire code official.
Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certificate used under provisions of this code, shall be guilty of a [SPECIFY OFFENSE], punishable by a fine of not more than [AMOUNT] dollars or by imprisonment not exceeding [NUMBER OF DAYS], or both such fine and imprisonment. Each day that a violation continues after due notice has been served shall be deemed a separate offense.
In addition to the imposition of the penalties herein described, the fire code official is authorized to institute appropriate action to prevent unlawful construction or to restrain, correct or abate a violation; or to prevent illegal occupancy of a structure or premises; or to stop an illegal act, conduct of business or occupancy of a structure on or about any premises.
If during the inspection of a premises, a building or structure, or any building system, in whole or in part, constitutes a clear and inimical threat to human life, safety or health, the fire code official shall issue such notice or orders to remove or remedy the conditions as shall be deemed necessary in accordance with this section, and shall refer the building to the building department for any repairs, alterations, remodeling, removing or demolition required.
Structures or existing equipment that are or hereafter become unsafe or deficient because of inadequate means of egress or which constitute a fire hazard, or are otherwise dangerous to human life or the public welfare, or which involve illegal or improper occupancy or inadequate maintenance, shall be deemed an unsafe condition. A vacant structure which is not secured against unauthorized entry as required by Section 311 shall be deemed unsafe.
When an apparent structural hazard is caused by the faulty installation, operation or malfunction of any of the items or devices governed by this code, the fire code official shall immediately notify the building code official in accordance with Section 110.1.
The fire code official or the fire department official in charge of an incident shall be authorized to order the immediate evacuation of any occupied building deemed unsafe when such building has hazardous conditions that present imminent danger to building occupants. Persons so notified shall immediately leave the structure or premises and shall not enter or re-enter until authorized to do so by the fire code official or the fire department official in charge of the incident.
Where conditions exist that are deemed hazardous to life and property, the fire code official or fire department official in charge of the incident is authorized to abate summarily such hazardous conditions that are in violation of this code.
The owner, operator or occupant of a building or premises deemed unsafe by the fire code official shall abate or cause to be abated or corrected such unsafe conditions either by repair, rehabilitation, demolition or other approved corrective action.
Whenever the fire code official finds any work regulated by this code being performed in a manner contrary to the provisions of this code, or in a dangerous or unsafe manner, the fire code official is authorized to issue a stop work order.
A stop work order shall be in writing and shall be given to the owner of the property, or to the owner's agent, or to the person doing the work. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reason for the order, and the conditions under which the cited work is authorized to resume.
Where an emergency exists, the fire code official shall not be required to give a written notice prior to stopping the work.
Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be liable to a fine of not less than [AMOUNT] dollars or more than [AMOUNT] dollars.
The fire code official shall have the authority to authorize disconnection of utility service to the building, structure or system in order to safely execute emergency operations or to eliminate an immediate hazard. The fire code official shall notify the serving utility and, whenever possible, the owner and occupant of the building, structure or service system of the decision to disconnect prior to taking such action if not notified prior to disconnection. The owner or occupant of the building, structure or service system shall be notified in writing as soon as practical thereafter.

Section 113 Fees

AMENDMENT
This section has been amended at the state or city level.

[A] 113.1 Fees

AMENDMENT
This section has been amended at the state or city level.

[A] 113.2 Schedule of Permit Fees

AMENDMENT
This section has been amended at the state or city level.

[A] 113.3 Work Commencing Before Permit Issuance

AMENDMENT
This section has been amended at the state or city level.

[A] 113.4 Related Fees

AMENDMENT
This section has been amended at the state or city level.

[A] 113.5 Refunds

AMENDMENT
This section has been amended at the state or city level.