This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section C106.
AAMA | American Architectural Manufacturers Association | |
1827 Walden Office Square | ||
Suite 550 | ||
Schaumburg, IL 60173-4268 | ||
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A C440—11 | North American Fenestration Standard/ Specifications for Windows, Doors and Unit Skylights | Table C402.4.3 |
AHAM | Association of Home Appliance Manufacturers | ||
1111 19th Street, NW, Suite 402 | |||
Washington, DC 20036 | |||
Standard reference number | Title | Referenced in code section number | |
ANSI/ AHAM RAC-1—2008 | Room Air Conditioners | Table C403.2.3(3) |
AHRI | Air Conditioning, Heating, and Refrigeration Institute | |
4100 North Fairfax Drive | ||
Suite 200 | ||
Arlington, VA 22203 | ||
Standard reference number | Title | Referenced in code section number |
ISO/AHRI/ASHRAE 13256-1 (2005) | Water-source Heat Pumps—Testing and Rating for Performance— Part 1: Water-to-air and Brine-to-air Heat Pumps | Table C403.2.3(2) |
ISO/AHRI/ASHRAE 13256-2 (1998) | Water-source Heat Pumps—Testing and Rating for Performance— Part 2: Water-to-water and Brine-to-water Heat Pumps | Table C403.2.3(2) |
210/240—08 | Unitary Air Conditioning and Air-source Heat Pump Equipment | Table C403.2.3(1), Table C403.2.3(2) |
310/380—04 | Standard for Packaged Terminal Air Conditioners and Heat Pumps | Table C403.2.3(3) |
340/360—2007 | Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment | Table C403.2.3(1), Table C403.2.3(2) |
365—09 | Commercial and Industrial Unitary Air-conditioning Condensing Units | Table C403.2.3(1), Table C403.2.3(6) |
390—03 | Performance Rating of Single Package Vertical Air Conditioners and Heat Pumps | Table C403.2.3(3) |
400—01 | Liquid to Liquid Heat Exchangers with Addendum 2 | Table C403.2.3(9) |
440—08 | Room Fan Coil | C403.2.8 |
460—05 | Performance Rating Remote Mechanical Draft Air-cooled Refrigerant Condensers | Table C403.2.3(8) |
550/590—03 | Water Chilling Packages Using the Vapor Compression Cycle—with Addenda | C403.2.3.1, Table C403.2.3(7), Table C406.2(6) |
560—00 | Absorption Water Chilling and Water-heating Packages | Table C403.2.3(7) |
1160—08 | Performance Rating of Heat Pump Pool Heaters | Table C404.2 |
840-1998 | Unit Ventilators | 403.2.8 |
AMCA | Air Movement and Control Association International | ||
30 West University Drive | |||
Arlington Heights, IL 60004-1806 | |||
Standard reference number | Title | Referenced in code section number | |
500D—10 | Laboratory Methods for Testing Dampers for Rating | C402.4.5.1, C402.4.5.2 |
ANSI | American National Standards Institute | ||
25 West 43rd Street | |||
Fourth Floor | |||
New York, NY 10036 | |||
Standard reference number | Title | Referenced in code section number | |
Z21.10.3/CSA 4.3—04 | Gas Water Heaters, Volume III—Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous | Table C404.2 | |
Z21.47/CSA 2.3—06 | Gas-fired Central Furnaces | Table C403.2.3(4), Table C406.2.(4) | |
Z83.8/CSA 2.6—09 | Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces | Table C403.2.3(4), Table C406.2.(4) |
ASHRAE | American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. | ||
1791 Tullie Circle, NE | |||
Atlanta, GA 30329-2305 | |||
Standard reference number | Title | Referenced in code section number | |
ANSI/ASHRAE/ACCA Standard 183—2007 | Peak Cooling and Heating Load Calculations in Buildings, Except Low-rise Residential Buildings | C403.2.1 | |
ASHRAE—2004 | ASHRAE HVAC Systems and Equipment Handbook—2004 | C403.2.1 | |
ISO/AHRI/ASHRAE 13256-1 (2005) | Water-source Heat Pumps—Testing and Rating for Performance— Part 1: Water-to-air and Brine-to-air Heat Pumps | Table C403.2.3(2) | |
ISO/AHRI/ASHRAE 13256-2 (1998) | Water-source Heat Pumps—Testing and Rating for Performance— Part 2: Water-to-water and Brine-to-water Heat Pumps | Table C403.2.3(2) | |
90.1—2010 | Energy Standard for Buildings Except Low-rise Residential Buildings | C401.2, C401.2.1, C402.1.1, Table C402.1.2, Table C402.2, Table C407.6.1 | |
119—88 (RA 2004) | Air Leakage Performance for Detached Single-family Residential Buildings | Table C405.5.2(1) | |
140—2010 | Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs | C407.6.1 | |
146—2006 | Testing and Rating Pool Heaters | Table C404.2 |
ASTM | ASTM International | ||
100 Barr Harbor Drive | |||
West Conshohocken, PA 19428-2859 | |||
Standard reference number | Title | Referenced in code section number | |
C 90—08 | Specification for Load-bearing Concrete Masonry Units | Table C402.2 | |
C 1371—04 | Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers | Table C402.2.1.1 | |
C 1549—04 | Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using A Portable Solar Reflectometer | Table C405.2.1.1 | |
D 1003—07e1 | Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics | C402.3.2.2 | |
E 283—04 | Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen | Table C402.2.1.1, C402.4.1.2.2, Table C402.4.3, C402.4.4, C402.4.8 | |
E 408—71(2002) | Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques | Table C402.2.1.1 | |
E 779—03 | Standard Test Method for Determining Air Leakage Rate by Fan Pressurization | C402.4.1.2.3 | |
E 903—96 | Standard Test Method Solar Absorptance, Reflectance and Transmittance of Materials Using Integrating Spheres (Withdrawn 2005) | Table C402.2.1.1 | |
E 1677—05 | Standard Specification for an Air-retarder (AR) Material or System for Low-rise Framed Building Walls | C402.4.1.2.2 | |
E 1918—97 | Standard Test Method for Measuring Solar Reflectance of Horizontal or Low-sloped Surfaces in the Field | Table C402.2.1.1 | |
E 1980—(2001) | Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces | Table C402.2.1.1 | |
E 2178—03 | Standard Test Method for Air Permanence of Building Materials | C402.4.1.2.1 | |
E 2357—05 | Standard Test Method for Determining Air Leakage of Air Barriers Assemblies | C404.1.2.2 |
CSA | Canadian Standards Association | ||
5060 Spectrum Way | |||
Mississauga, Ontario, Canada L4W 5N6 | |||
Standard reference number | Title | Referenced in code section number | |
AAMA/WDMA/CSA 101/I.S.2/A440—11 | North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights | Table C402.4.3 |
CTI | Cooling Technology Institute | ||
2611 FM 1960 West, Suite A-101 | |||
Houston, TX 77068 | |||
Standard reference number | Title | Referenced in code section number | |
ATC 105 (00) | Acceptance Test Code for Water Cooling Tower | Table C403.2.3(8) | |
STD 201—09 | Standard for Certification of Water Cooling Towers Thermal Performances | Table C403.2.3(8) |
DASMA | Door and Access Systems Manufacturers Association | ||
1300 Sumner Avenue | |||
Cleveland, OH 44115-2851 | |||
Standard reference number | Title | Referenced in code section number | |
105—92 (R2004) | Test Method for Thermal Transmittance and Air Infiltration of Garage Doors | Table C402.4.3 |
DOE | U.S. Department of Energy | ||
c/o Superintendent of Documents | |||
U.S. Government Printing Office | |||
Washington, DC 20402-9325 | |||
Standard reference number | Title | Referenced in code section number | |
10 CFR, Part 430—1998 | Energy Conservation Program for Consumer Products: Test Procedures and Certification and Enforcement Requirement for Plumbing Products; and Certification and Enforcement Requirements for Residential Appliances; Final Rule | Table C403.2.3(4), Table C403.2.3(5), Table C404.2, Table C406.2(4), Table C406.2(5) | |
10 CFR, Part 430, Subpart B, Appendix N—1998 | Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers | C202 | |
10 CFR, Part 431—2004 | Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures and Efficiency Standards; Final Rules | Table C403.2.3(5), Table C406.2(5) | |
NAECA 87—(88) | National Appliance Energy Conservation Act 1987 [(Public Law 100-12 (with Amendments of 1988-P.L. 100-357)] | Tables C403.2.3(1), (2), (4) |
ICC | International Code Council, Inc. | ||
500 New Jersey Avenue, NW | |||
6th Floor | |||
Washington, DC 20001 | |||
Standard reference number | Title | Referenced in code section number | |
IBC—12 | International Building Code® | C201.3, C303.2, C402.4.4 | |
IFC—12 | International Fire Code® | C201.3 | |
IFGC—12 | International Fuel Gas Code® | C201.3 | |
IMC—12 | International Mechanical Code® | C403.2.5, C403.2.5.1, C403.2.6, C403.2.7, C403.2.7.1, C403.2.7.1.1, C403.2.7.1.2, C403.2.7.1.3, C403.4.5, C408.2.2.1 | |
IPC—12 | International Plumbing Code® | C201.3 |
IESNA | Illuminating Engineering Society of North America | ||
120 Wall Street, 17th Floor | |||
New York, NY 10005-4001 | |||
Standard reference number | Title | Referenced in code section number | |
ANSI/ASHRAE/IESNA 90.1—2010 | Energy Standard for Buildings, Except Low-rise Residential Buildings | C401.2, C401.2.1, C402.1.1, Table C402.1.2, Table C402.2 |
ISO | International Organization for Standardization | ||
1, rue de Varembe, Case postale 56, CH-1211 | |||
Geneva, Switzerland | |||
Standard reference number | Title | Referenced in code section number | |
ISO/AHRI/ASHRAE 13256-1 (2005) | Water-source Heat Pumps—Testing and Rating for Performance— Part 1: Water-to-air and Brine-to-air Heat Pumps | C403.2.3(2) | |
ISO/AHRI/ASHRAE 13256-2 (1998) | Water-Source Heat Pumps—Testing and Rating for Performance— Part 2: Water-to-water and Brine-to-water Heat Pumps | C403.2.3(2) |
NFRC | National Fenestration Rating Council, Inc. | ||
6305 Ivy Lane, Suite 140 | |||
Greenbelt, MD 20770 | |||
Standard reference number | Title | Referenced in code section number | |
100—2010 | Procedure for Determining Fenestration Products U-factors—Second Edition | C303.1.2, C402.2.1 | |
200—2010 | Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence—Second Edition | C303.1.3, C402.3.1.1 | |
400—2010 | Procedure for Determining Fenestration Product Air Leakage—Second Edition | Table C402.4.3 |
SMACNA | Sheet Metal and Air Conditioning Contractors National Association, Inc. | ||
4021 Lafayette Center Drive | |||
Chantilly, VA 20151-1209 | |||
Standard reference number | Title | Referenced in code section number | |
SMACNA—85 | HVAC Air Duct Leakage Test Manual | C403.2.7.1.3 |
UL | Underwriters Laboratories | ||
333 Pfingsten Road | |||
Northbrook, IL 60062-2096 | |||
Standard reference number | Title | Referenced in code section number | |
727—06 | Oil-fired Central Furnaces—with Revisions through April 2010 | Table C403.2.3(4), Table C406.2(4) | |
731—95 | Oil-fired Unit Heaters—with Revisions through April 2010 | Table C403.2.3(4), Table C406.2(4) |
US—FTC | United States - Federal Trade Commission | ||
600 Pennsylvania Avenue NW | |||
Washington, DC 20580 | |||
Standard reference number | Title | Referenced in code section number | |
CFR Title 16 (May 31, 2005) | R-value Rule | C303.1.4 |
WDMA | Window and Door Manufacturers Association | ||
1400 East Touhy Avenue, Suite 470 | |||
Des Plaines, IL 60018 | |||
Standard reference number | Title | Referenced in code section number | |
AAMA/WDMA/CSA 101/I.S.2/A440—11 | North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights | Table C402.4.3 |