This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.
ASCE/SEI | American Society of Civil Engineers Structural Engineering Institute 1801 Alexander Bell Drive Reston, VA 20191-4400 | |
Standard reference Number | Title | Referenced in code section number |
7—10 | Minimum Design Loads for Buildings and Other Structures with Supplement No. 1 | 301.1.4.1 |
31—03 | Seismic Evaluation of Existing Buildings | 301.1.4, Table 301.1.4.2, 301.1.4.2 |
41—06 | Seismic Rehabilitation of Existing Buildings | 301.1.4, 301.1.4.1, Table 301.1.4.1, 301.1.4.2, Table 301.1.4.2 |
ASHRAE | American Society of Heating, Refrigerating and Air Conditioning Engineers 1791 Tullie Circle, NE Atlanta, GA 30329 | |
Standard reference Number | Title | Referenced in code section number |
62.1—2010 | Ventilation for Acceptable Indoor Air Quality | 809.2 |
ASME | American Society of Mechanical Engineers 3 Park Avenue New York, NY 10016 | |
Standard reference Number | Title | Referenced in code section number |
ASME/ A17.1—2007/ CSA B44—2007 | Safety Code for Elevators and Escalators—with A17.1a/CSA B44a—08 Addenda | 410.8.2, 705.1.2, 902.1.2 |
A17.3—2008 | Safety Code for Existing Elevators and Escalators | 902.1.2 |
A18.1—2008 | Safety Standard for Platform Lifts and Stairway Chair Lifts | 410.8.3, 705.1.3 |
ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 | |
Standard reference Number | Title | Referenced in code section number |
C 90—08 | Standard Specification for Load-bearing Concrete Masonry Units | A505.2.3 |
C 496—96 | Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens | A104, A106.3.3.2 |
E 519—00e1 | Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages | A104, A106.3.3.2 |
DOC | United States Department of Commerce 1401 Constitution Avenue, NW Washington, DC 20230 | |
Standard reference Number | Title | Referenced in code section number |
PS 1—09 | Structural Plywood | A302 |
PS 2—10 | Performance Standard for Wood-based Structural-use Panels | A302 |
ICC | International Code Council, Inc. 500 New Jersey Avenue, NW, 6th Floor Washington, DC 20001 | |
Standard reference Number | Title | Referenced in code section number |
IBC—12 | International Building Code® | 101, 106, 109, 110, 202, 301, 407, 410, 501, 601, 602, 606, 701, 702, 705, 706, 801, 802, 803, 804, 805, 806, 807, 904, 905, 907, 1001, 1002, 1007, 1011, 1012, 1102, 1103, 1104, 1201, 1202, 1203, 1204, 1205, 1301, 1302, 1201, 1501, 1506 |
ICC A117.1—2009 | Accessible and Usable Buildings and Facilities | 410.6, 410.8.2, 705.1, 705.1.2, 705.1.3 |
IECC—12 | International Energy Conservation Code® | 702.4, 707.1, 811.1, 908.1 |
IFC—12 | International Fire Code® | 101.4.2, 301.1.1, 803.2.1, 803.2.3, 804.4.1.1, 804.4.1.2, 804.4.1.3, 804.4.1.4, 804.4.1.5, 804.4.1.6, 804.4.1.7, 804.4.3, 1301.2, 1401.3.2, 1401.6.8.1, 1401.6.14, 1401.6.14.1, 1504.1, 1504.2 |
IFGC—12 | International Fuel Gas Code® | 407.7, 702.4.1 |
IMC—12 | International Mechanical Code® | 407.8, 702.4, 809.1, 902.1.1, 1002.2.1, 1009.1, 1401.6.7.1, 1401.6.8, 1401.6.8.1 |
IPC—12 | International Plumbing Code® | 407.9, 609.1, 702.4, 810.1, 1010.2, 1010.3, 1010.5, 1501.5 |
IPMC—12 | International Property Maintenance Code® | 101.4.2, 1301.2, 1401.3.2 |
IRC—12 | International Residential Code® | 101.4.1, 602.3, 606, 706.2.1, 707.1, 807.4, 808.3, 811.1, 907.4, 907.4.2, 908.1, 1103.2, 1103.3, 1103.4, 1104.1, 1302.1, 1302.2, 1302.2.1, 1302.3, 1302.4, 1302.5, 1401.2.2, 1401.2.3 |
NFPA | National Fire Protection Agency 1 Batterymarch Park Quincy, MA 02269-9101 | |
Standard reference Number | Title | Referenced in code section number |
NFPA 13R—10 | Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height | 804.2.5 |
NFPA 70—11 | National Electrical Code | 607.1.1, 607.1.2, 607.1.3, 607.1.4, 607.1.5 |
NFPA 72—10 | National Fire Alarm Code | 804.2.5, 804.4 |
NFPA 99—10 | Health Care Facilities | 607.1.4 |
NFPA 101—12 | Life Safety Code | 805.2 |