This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

Supplemental standards. The standards listed in this part shall supplement the list of referenced standards in Chapter 15 of the 2012 IMC. The standards referenced in this rule shall be considered part of the requirements of this rule to the extent prescribed in each rule or reference.

ACCAAir Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
TitleReferenced
in code
section number
Manual D—09Residential Duct Systems603.2
183—2007Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings312.1
AHRIAir-Conditioning, Heating and Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
Standard
reference
number
TitleReferenced
in code
section number
700—2006Purity Specifications for Fluorocarbon and Other Refrigerants1102.2.2.3
AMCAAir Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
Standard
reference
number
TitleReferenced
in code
section number
550—08Test Method for High Velocity Wind Driven Rain Resistant Louvers401.5, 501.3.2
ANSIAmerican National Standards Institute
11 West 42nd Street
New York, NY 10036
Standard
reference
number
TitleReferenced
in code
section number
Z21.8—1994 (R2002)Installation of Domestic Gas Conversion Burners919.1
ASHRAEAmerican Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
number
TitleReferenced
in code
section number
ASHRAE—2009ASHRAE Fundamentals Handbook 603.2
15—2010Safety Standard for Refrigeration Systems1101.6, 1105.8, 1108.1
34—2010Designation and Safety Classification of Refrigerants202, 1102.2.1, 1103.1
62.1—2010Ventilation for Acceptable Indoor Air Quality 403.3.2.3.2
154—2011Ventilation for Commercial Cooking Operations507.2
180—2008Standard Practice for Inspection and Maintenance of Commercial
Building HVAC Systems
102.3
ASMEAmerican Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—1983 (R2006) Pipe Threads, General Purpose (Inch) 1203.3.5, 1303.3.3
B16.3—2006Malleable Iron Threaded Fittings, Classes 150 & 300Table 1202.5
B16.5—2003Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24Table 1202.5
B16.9—2007Factory Made Wrought Steel Buttwelding FittingsTable 1202.5
B16.11—2005Forged Fittings, Socket-welding and ThreadedTable 1202.5
B16.15—2006Cast Bronze Threaded FittingsTable 1202.5
B16.18—2001
(Reaffirmed 2005)
Cast Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.22—2001
(Reaffirmed 2005)
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.23—2002
(Reaffirmed 2006)
Cast Copper Alloy Solder Joint Drainage Fittings DWVTable 1202.5
B16.24—2006Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900,
1500 and 2500
Table 1202.5
B16.26—2006Cast Copper Alloy Fittings for Flared Copper TubesTable 1202.5
B16.28—1994Wrought Steel Buttwelding Short Radius Elbows and ReturnsTable 1202.5
B16.29—2007Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings-DWVTable 1202.5
B31.3—2008Process Piping CodeMinnesota Rule 1346.0101
B31.9—2008 Building Services Piping 1201.3
BPVC—2007 ASME Boiler & Pressure Vessel Code (Sections I, II, IV, V, VIII and IX) 1003.1, 1006.4, 1011.1
CSD-1—2009 Controls and Safety Devices for Automatically Fired Boilers 1004.1, 1006.9
ASSEAmerican Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
Standard
reference
number
TitleReferenced
in code
section number
1017—2010Performance Requirements for Temperature Actuated Mixing Values for
Hot Water Distribution Systems
1002.2.2
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
reference
number
TitleReferenced
in code
section number
A 53/A 53M—07Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded
and Seamless
Table 1202.4, Table 1302.3
A 106/A106M—08Specification for Seamless Carbon Steel Pipe for High-Temperature ServiceTable 1202.4, Table 1302.3
A 126—04Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings Table 1202.5
A 254—97 (2007)Specification for Copper Brazed Steel TubingTable 1202.4, Table 1302.3
A 420/A 420M—07Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel
for Low-Temperature Service
Table 1202.5
A 539—99Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil LinesTable 1302.3
B 32—08Specification for Solder Metal1203.3.3
B 42—02e01Specification for Seamless Copper Pipe, Standard Sizes513.13.1, 1107.5.2, Table 1202.4, Table 1302.3
B 43—98(2004)Specification for Seamless Red Brass Pipe, Standard Sizes513.13.1, 1107.5.2, Table 1202.4, Table 1302.3
B 68—02Specification for Seamless Copper Tube, Bright Annealed513.13.1
B 75—02Specification for Seamless Copper TubeTable 1202.4, Table 1302.3
B 88—03Specification for Seamless Copper Water Tube513.13.1, 1107.5.3, Table 1202.4, Table 1302.3
B 135—08aSpecification for Seamless Brass TubeTable 1202.4, Table 1302.3
B 251—02e01Specification for General Requirements for Wrought Seamless Copper
and Copper-alloy Tube
513.13.1, Table 1202.4
B 280—08Specification for Seamless Copper Tube for Air Conditioning and
Refrigeration Field Service
513.13.1, 1107.4.3, Table 1302.3
B 302—07Specification for Threadless Copper Pipe, Standard SizesTable 1202.4, Table 1302.3
B 813—00(2009)Specification for Liquid and Paste Fluxes for Soldering of Copper and
Copper Alloy Tube
1203.3.3
C 315—07Specification for Clay Flue Liners and Chimney Pots801.16.1, Table 803.10.4
C 411—05Test Method for Hot-surface Performance of High-temperature Thermal Insulation604.3
D 56—05Test Method for Flash Point by Tag Closed Tester202
D 93—08Test Method for Flash Point of Pensky-Martens Closed Cup Tester 202
D 1527—99(2005)Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80Table 1202.4
D 1693—08Test Method for Environmental Stress-Cracking of Ethylene PlasticsTable 1202.4
D 1785—06Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe, Schedules 40, 80 and 120Table 1202.4
D 2235—04Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS)
Plastic Pipe and Fittings
1203.3.4
D 2241—05Specification for Poly (Vinyl Chloride)(PVC) Pressure-rated Pipe (SDR-Series)Table 1202.4
D 2282—99(2005)Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)Table 1202.4
D 2412—02(2008)Test Method for Determination of External Loading Characteristics of Plastic Pipe
by Parallel-plate Loading
603.8.3
D 2447—03Specification for Polyethylene (PE) Plastic Pipe, Schedules 40 and 80, Based on Outside DiameterTable 1202.4
D 2466—06Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 40Table 1202.5
D 2467—06Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 80Table 1202.5
D 2468—96aSpecification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40 Table 1202.5
D 2513—08bSpecification for Thermoplastic Gas Pressure Pipe, Tubing, and FittingsTable 1202.4
D 2564—04e01Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems1203.3.4
D 2657—07Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings1203.15.1
D 2683—04Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled
Polyethylene Pipe and Tubing
Table 1202.4, 1203.15.1
D 2837—08Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or
Pressure Design Basis for Thermoplastic Pipe Products
Table 1202.4
D 2846/D 2846M—09Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and
Cold Water Distribution Systems
Table 1202.4, 1203.3.4
D 2996—01(2007)e01Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe .Table 1302.3
D 3035—08Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter.Table 1202.4
D 3278—96(2004)Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus202
D 3261—03Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for
Polyethylene (PE) Plastic Pipe and Tubing
1203.15.1
D 3309—96a(2002)Specification for Polybutylene (PB) Plastic Hot and Cold Water Distribution Systems.Table 1202.4, 1203.10.1
D 3350—08Specification for Polyethylene Plastics Pipe and Fittings MaterialsTable 1202.4
E 84—09Test Method for Surface Burning Characteristics of Building Materials202, 510.8, 602.2.1,
602.2.1.5, 604.3, 1204.1
E 119—08aTest Method for Fire Tests of Building Construction and Materials607.5.2,607.5.5, 607.6.1, 607.2.1
E 136—09Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C202
E 814—08bTest Method for Fire Tests of Through-penetration Fire Stops506.3.10.2, 506.3.10.3
E 1509—04Specification for Room Heaters, Pellet Fuel-burning Type904.1
E 1998—02Standard Guide for Assessing Depressurization-Induced Backdrafting and Spillage from Vented
Combustion Appliances
501.4.1, 501.4.3
E 2231—04Standard Practice For Specimen Preparation and Mounting of Pipe and Duct Insulation Materials
to Assess Surface Burning Characteristics
604.3, 1204.1
E 2336—04Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems506.3.6, 506.3.10.2
F 438—04Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
Schedule 40
Table 1202.5
F 439—06Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
Schedule 80
Table 1202.5
F 441/F 441M—02(2008)Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80Table 1202.4
F 442/F 442M—99(2005)e1Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)Table 1202.4
F 493—04Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe
and Fittings
1203.3.4
F 876—08bSpecification for Crosslinked Polyethylene (PEX) TubingTable 1202.4
F 877—07Specification for Crosslinked Polyethylene (PEX) Plastic Hot and Cold Water
Distribution Systems
Table 1202.4, Table 1202.5
F 1055—98(2006)Specification for Electrofusion Type Polyethylene Fittings for Outside
Diameter Controlled Polyethylene Pipe and Tubing
Table 1202.4, 1203.15.2
F 1281—07Specification for Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene
(PEX-AL-PEX) Pressure Pipe
Table 1202.4
F 1282—06Standard Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite
Pressure Pipe
Table 1202.4
F 1476—07Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications1203.3.7
F 1807—08Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR 9
Cross-linked Polyethylene (PEX) Tubing
Table 1202.5
F 1924—05Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled
Polyethylene Gas Distribution Pipe and Tubing
1203.15.3
F 1974—08Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked
Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe
Table 1202.5
F 2159—05Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR 9
Cross-linked Polyethylene (PEX) Tubing
Table 1202.5
F 2389—07e1Specification for Pressure-rated Polypropylene Piping SystemsTable 1202.4, Table 1202.5
F 2623—08Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing1Table 1202.4
F 2735—08aStandard Specification for Plastic Insert Fittings for SDR 9 Cross-linked Polyethylene (PEX)
and Raised Temperature (PE-RT) Tubing
Table 1202.5
F 2769—09Polyethylene of Raised Temperature (PE-RT) Plastic Hot and Cold-water Tubing and
Distribution Systems
Table 1202.4
AWSAmerican Welding Society
550 N.W. LeJeune Road
P.O. Box 351040
Miami, FL 33135
Standard
reference
number
TitleReferenced
in code
section number
A5.8—2004Specifications for Filler Metals for Brazing and Braze Welding1203.3.1, 1303.3.1
AWWAAmerican Water Work Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
TitleReferenced
in code
section number
C110/A21.10—03Standard for Ductile Iron & Gray Iron Fittings, 2 inches Through 48 inches for WaterTable 1202.5
C115/A21.15—99Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded FlangesTable 1202.4
C151/A21.51—02Standard for Ductile-iron Pipe, Centrifugally Cast for WaterTable 1202.4
C153/A21.53—00Standard for Ductile-iron Compact Fittings for Water ServiceTable 1202.5
CSACanadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
reference
number
TitleReferenced
in code
section number
B137.9—05Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe SystemsTable 1202.4
B137.10—05Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX)
Composite Pressure-pipe Systems
Table 1202.4
ANSI CSA
America FC1—03
Stationary Fuel Cell Power Systems924.1
DOLDepartment of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
TitleReferenced
in code
section number
29 CFR Part 1910.1000
(2009)
Air Contaminants502.6
29 CFR Part 1910.1025
(2009)
Toxic and Hazardous Substances502.19
FSFederal Specifications*
General Services Administration
7th & D Streets
Specification Section, Room 6039
Washington, DC 20407
Standard
reference
number
TitleReferenced
in code
section number
WW-P-325B (1976)Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and
Waste Applications
Table 1202.4
*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325
ICCInternational Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
TitleReferenced
in code
section number
IBC—12International Building Code®201.3, 202,301.12, 301.12, 301.14, 301.15,
302.1, 302.2, 304.7, 304.10, 308.8, 308.10,
401.4, 401.6, 406.1, 502.10, 502.10.1, 504.2,
506.3.3, 506.3.10, 506.3.12.2, 506.4.1, 509.1,
510.6, 510.6.3, 510.6.2, 510.7, 511.1.5, 513.1,
513.2, 513.3, 513.4.3, 513.5, 513.5.2, 513.5.2.1,
513.6.2, 513.10.5, 513.12, 513.12.2, 513.20,
602.2.1.5.1, 602.2.1.5.2, 602.3,603.1, 603.10,
604.5.4, 607.1.1, 607.3.2.1, 607.5.1, 607.5.2,
607.5.3, 607.5.4, 607.5.4.1, 607.5.5, 607.5.5.1,
607.6, 607.6.2, 701.4.1, 701.4.2, 801.3, 801.16.1,
801.18.4, 902.1, 908.3, 908.4, 910.3, 925.1,
1004.6, 1105.1, 1206.4, 1402.4, 1402.4.1
IEBC—12International Existing Building Code®101.2
IECC—12International Energy Conservation Code®202, 301.2, 303.3, 312.1, 603.9, 604.1, 1204.1, 1204.2
IFC—12International Fire Code®201.3, 310.1, 311.1, 502.4, 502.5,
502.7.2, 502.8.1, 502.9.5, 502.9.5.2, 502.9.5.3,
502.9.8.2, 502.9.8.3, 502.9.8.5, 502.9.8.6, 502.10,
502.10.3, 502.16.2, 509.1, 510.2.1, 510.2.2, 510.4,
511.1.1 513.12.3, 513.15, 513.16, 513.17, 513.18, 513.19,
513.20.2, 513.20.3, 606.2.1, 908.7, 1101.9,
1105.3, 1105.9, 1106.5, 1106.6, 1301.1, 1301.2
IFGC—12International Fuel Gas Code®101.2, 201.3, 301.3, 701.1, 801.1, 901.1, 906.1, 1101.5
IPC—12International Plumbing Code®201.3, 301.8, 512.2, 908.5, 1002.1, 1002.2,
1002.3, 1005.2, 1006.6, 1008.2, 1009.3,
1101.4, 1201.1, 1206.2, 1206.3, 1401.2
IRC—12International Residential Code®101.2
IIARInternational Institute of Ammonia Refrigeration
1110 North Glebe Road
Arlington, VA 22201
Standard
reference
number
TitleReferenced
in code
section number
2—99
(with Addendum A—2005)
Addendum A to Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems1101.6
MSSManufacturers Standardization Society of the Valve & Fittings Industry, Inc.
127 Park Street, N.E.
Vienna, VA 22180
Standard
reference
number
TitleReferenced
in code
section number
SP-69—2002Pipe Hangers and Supports-Selection and Application305.4
NAIMANorth American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
reference
number
TitleReferenced
in code
section number
AH116—09Fibrous Glass Duct Construction Standards603.5, 603.9
NFPANational Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Standard
reference
number
Title Referenced
in code
section number
30A—12 Code for Motor Fuel-dispensing Facilities and Repair Garages 304.6
31—11Installation of Oil-burning Equipment 801.2.1, 801.18.1, 801.18.2, 920.2, 922.1, 1308.1
37—10Stationary Combustion Engines and Gas Turbines 915.1, 915.2
45—2011Standard on Fire Protection for Laboratories Using Chemicals 510.1
54—2012National Fuel Gas CodeIFGC 301.3
58—11Liquefied Petroleum Gas Code 502.9.10
69—08Explosion Prevention Systems 510.8.3
70—11National Electrical Code 301.7, 306.3.1, 306.4.1, 511.1.1,
513.11, 513.12.1, 602.2.1.1, 1106.3, 1106.4
72—10National Fire Alarm Code 606.3
82—09Incinerators and Waste and Linen Handling Systems and Equipment 601.1
85—2011Boiler and Combustion Systems Hazards Code 301.7
90B—2012Standard for the Installation of Warm Air Heating and Air-Conditioning Systems 301.7
91—10Exhaust Systems for Air Conveying of Vapors, Gases, and Noncombustible
Particulate Solids
502.9.5.1, 502.17
92B—09Smoke Management Systems in Malls, Atria and Large Spaces 513.8
96—2014Standard for Ventilation Control and Fire Protection of Commercial
Cooking Operations
Minnesota Rule 1346.0050, 506.3, 506.3.1, 507.7.1
211—10Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 806.1
262—11Standard Method of Test for Flame Travel and Smoke of Wires and Cables for
Use in Air-handling Spaces
602.2.1.1
704—12Identification of the Hazards of Materials for Emergency Response 502.8.4, Table 1103.1, 510.1
853—10Installation of Stationary Fuel Power Plants 924.1
850 1—97Single Burner Boiler Operation 1004.1
8502—99Prevention of Furnace Explosions/Implosions in Multiple Burner Boiler-furnaces 1004.1
8504—96Atmospheric Fluidized-bed Boiler Operation 1004.1
SMACNASheet Metal & Air Conditioning Contractors National Assoc., Inc.
4201 Lafayette Center Drive
Chantilly, VA 20151-1209
Standard
reference
number
TitleReferenced
in code
section number
SMACNA/ANSI—2005HVAC Duct Construction Standards-Metal and Flexible (2005)603.4, 603.9
SMACNA—03Fibrous Glass Duct Construction Standards603.5, 603.9
ULUnderwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
TitleReferenced
in code
section number
17—2008Vent or Chimney Connector Dampers for Oil-fired Appliances803.6
103—01Factory-built Chimneys, Residential Type and Building Heating Appliance
with Revisions through March 2010
805.2
127—08Factory-built Fireplaces—with Revisions through January 2010805.3, 903.1, 903.3
174—04Household Electric Storage Tank Water Heaters—with Revisions through May 20061002.1
180—03Liquid-level Indicating Gauges for Oil Burner Fuels—with Revisions through March 20071306.4
181—05Factory-made Air Ducts and Air Connectors—with Revisions through October 2008512.2, 603.5, 603.6.1,
603.6.2, 604.13
181A—05Closure Systems for Use with Rigid Air Ducts and Air Connectors—
with Revisions through February 2008
603.9
181B—05Closure Systems for Use with Flexible Air Ducts and Air Connectors—
with Revisions through February 2008
603.9
207—2009Refrigerant-containing Components and Accessories, Nonelectrical1101.2
263—2003Standard for Fire Test of Building Construction and Materials—
with Revisions through October 2007
607.5.2, 607.5.5, 607.6.1
268—2009Smoke Detectors for Fire Prevention Signaling606.1
268A—2008Smoke Detectors for Duct Application, with Revisions through September 2009606.1
343—2008Pumps for Oil-Burning Appliances1302.7
378—06Draft Equipment804.3, 804.3.8
391—2006Solid-fuel and Combination-fuel Central and Supplementary Furnaces
with Revisions through March 2010
918.1
412—04Refrigeration Unit Coolers—with Revisions through January 20091101.2
471—06Commercial Refrigerators and Freezers—with Revisions through October 20081101.2
499—05Electric Heating Appliances—with Revisions through August 2008912.1, 923.1
508—99Industrial Control Equipment—with Revisions through September 2008307.2.3
536—97Flexible Metallic Hose—with Revisions through June 20031302.8
555—06Fire Dampers—with Revisions through May 2010607.3
555C—06Ceiling Dampers—with Revisions through May 2010607.3.1
555S—99Smoke Dampers—with Revisions through May 2010607.3.1
586—2009High-Efficiency, Particulate, Air Filter Units605.2
641—95Type L Low-temperature Venting Systems—with Revisions through July 2009802.1
710—95Exhaust Hoods for Commercial Cooking Equipment—with Revisions through December 2009507.1
710B—04Recirculating Systems with Revisions through April 2006507.1
723—2008Standard for Test for Surface Burning Characteristics of Building Materials510.8, 602.2.1,
602.2.1.5, 604.3, 1204.1
726—95Oil-fired Boiler Assemblies—with Revisions through April 2010916.1, 1004.1
727—06Oil-fired Central Furnaces918.1
729—03Oil-fired Floor Furnaces—with Revisions through April 2010910.1
730—03Oil-fired Wall Furnaces—with Revisions through April 2010909.1
731—95Oil-fired Unit Heaters—with Revisions through April 2010920.1
732—95Oil-fired Storage Tank Water Heaters—with Revisions through April 20101002.1
737—2007Fireplace Stoves—with Revisions through January 2010905.1
762—2010Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances506.5.1
791—06Residential Incinerators—with revisions through April 2010907.1
834—04Heating, Water Supply and Power Boilers Electric—with Revisions through December 2009 1004.1
842—07Valves for Flammable Fluids1307.1
858—05Household Electric Ranges—with Revisions through May 2010917.1
867—00Electrostatic Air Cleaners—with Revisions through February 2010 605.2
875—09Electric Dry Bath Heater—with Revisions through October 2009914.2
896—93Oil-burning Stoves—with Revisions through May 2010917.1, 922.1
900—04Air Filter Units—with Revisions through November 2009605.2
923—2008Microwave Cooking Appliances—with Revisions through June 2010914.2
907—94Fireplace Accessories—with Revisions through July 2006901.4
959—01Medium Heat Appliance Factory-built Chimneys—with Revisions through June 2010805.5
1046—00Grease Filters for Exhaust Ducts507.11
1240—05Electric Commercial Clothes—Drying Equipment—with Revisions through October 2009 913.1
1261—01Electric Water Heaters for Pools and Tubs—with Revisions through May 2008916.1
1453—04Electric Booster and Commercial Storage Tank Water Heaters
with Revisions through December 2009
1002.1
1479—03Fire Tests of Through-penetration Firestops—with Revisions through April 2007506.3.10.2, 506.3.10.3
1482—2010Solid-fuel Type Room Heaters905.1
1618—09Wall Protectors, Floor Protectors and Hearth Extensions308.5, 903.2, 905.3
1777—2007Chimney Liners—with Revisions through July 2009 801.16.1, 801.18.4
1812—2009Standard for Ducted Heat Recovery Ventilators—with Revisions through June 2010927.1
1815—2009Standard for Nonducted Heat Recovery927.2
1820—04Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics—
with Revisions through February 2009
602.2.1.3
1887—04Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics—
with Revisions through February 2009
602.2.1.2
1978—05Grease Ducts—with Revisions through June 2009 506.3.2
1995—05Heating and Cooling Equipment—with Revisions through July 2009911.1, 918.1, 918.3, 1101.2
1996—04Electric Duct Heaters—with Revisions through December 2006911.1
2024—2008Standard for Safety Optical-Fiber and Communications Cable Raceway602.2.1.1
2043—2008Fire Test for Heat and Visible Smoke Release for Discrete Products and their Accessories
Installed in Air-handling Spaces
602.2.1.4.2
2158—97Electric Clothes Dryers—with Revisions through March 2009504.6.3, 913.1
2158A—2006Outline of Investigation for Clothes Dryer Transition Duct504.6.3
2162—01Outline of Investigation for Commercial Wood-fired Baking Ovens-Refractory Type917.1
2200—98Stationery Engine Generator Assemblies—with Revisions through December 2009915.1
2221—01Tests of Fire Resistive Grease Duct Enclosure Assemblies506.3.10.3
2518—02Air Dispersion System Materials 603.17
2523—09Solid Fuel-fired Hydronic Heating Appliances1002.1, 1004.1
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING