Heads up: There are no amended sections in this chapter.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 106.

AAMAAmerican Architectural Manufacturers Association1827 Walden Office Square
Suite 550
Schaumburg, IL 60173-4268
Standard
Reference
Number
TitleReferenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A C440—11
North American Fenestration Standard/
Specifications for Windows, Doors and Unit Skylights
Table C402.4.3
AHAMAssociation of Home Appliance Manufacturers
1111 19th Street, NW, Suite 402
Washington, DC 20036
Standard
reference
number
TitleReferenced
in code
section number
ANSI/
AHAM RAC-1—2008
Room Air ConditionersTable C403.2.3(3)
AHRIAir Conditioning, Heating, and Refrigeration Institute
4100 North Fairfax Drive
Suite 200
Arlington, VA 22203
Standard
reference
number
TitleReferenced
in code
section number
ISO/AHRI/ASHRAE
13256-1 (2005)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 1: Water-to-air and Brine-to-air Heat Pumps
Table C403.2.3(2)
ISO/AHRI/ASHRAE
13256-2 (1998)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 2: Water-to-water and Brine-to-water Heat Pumps
Table C403.2.3(2)
210/240—08Unitary Air Conditioning and Air-source Heat Pump EquipmentTable C403.2.3(1), Table C403.2.3(2)
310/380—04Standard for Packaged Terminal Air Conditioners and Heat PumpsTable C403.2.3(3)
340/360—2007Commercial and Industrial Unitary Air-conditioning and
Heat Pump Equipment
Table C403.2.3(1), Table C403.2.3(2)
365—09Commercial and Industrial Unitary Air-conditioning
Condensing Units
Table C403.2.3(1), Table C403.2.3(6)
390—03Performance Rating of Single Package Vertical Air Conditioners
and Heat Pumps
Table C403.2.3(3)
400—01Liquid to Liquid Heat Exchangers with Addendum 2 Table C403.2.3(9)
440—08Room Fan CoilC403.2.8
460—05Performance Rating Remote Mechanical Draft Air-cooled
Refrigerant Condensers
Table C403.2.3(8)
550/590—03Water Chilling Packages Using the Vapor Compression Cycle—with Addenda C403.2.3.1 ,Table C403.2.3(7), Table C406.2(6)
560—00Absorption Water Chilling and Water-heating PackagesTable C403.2.3(7)
1160—08Performance Rating of Heat Pump Pool HeatersTable C404.2
AMCAAir Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004-1806
Standard
reference
number
TitleReferenced
in code
section number
500D—10Laboratory Methods for Testing Dampers for RatingC402.4.5.1, C402.4.5.2
ANSIAmerican National Standards Institute
25 West 43rd Street
Fourth Floor
New York, NY 10036
Standard
reference
number
TitleReferenced
in code
section number
Z21.10.3/CSA 4.3—04 Gas Water Heaters, Volume III—Storage Water Heaters with Input Ratings
Above 75,000 Btu per Hour, Circulating Tank and Instantaneous
Table C404.2
Z21.47/CSA 2.3—06Gas-fired Central FurnacesTable C403.2.3(4), Table C406.2.(4)
Z83.8/CSA 2.6—09Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters
and Gas-fired Duct Furnaces
Table C403.2.3(4), Table C406.2.(4)
ASHRAEAmerican Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329-2305
Standard
reference
number
TitleReferenced
in code
section number
ANSI/ASHRAE/ACCA
Standard 183—2007
Peak Cooling and Heating Load Calculations in Buildings,
Except Low-rise Residential Buildings
C403.2.1
ASHRAE—2004ASHRAE HVAC Systems and Equipment Handbook—2004C403.2.1
ISO/AHRI/ASHRAE
13256-1 (2005)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 1: Water-to-air and Brine-to-air Heat Pumps
Table C403.2.3(2)
ISO/AHRI/ASHRAE
13256-2 (1998)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 2: Water-to-water and Brine-to-water Heat Pumps
Table C403.2.3(2)
90.1—2010Energy Standard for Buildings Except Low-rise Residential Buildings
(ANSI/ASHRAE/IESNA 90.1—2007)
C401.2,C401.2.1,C402.1.1, Table C402.1.2,
Table C402.2, Table C407.6.1
119—88 (RA 2004)Air Leakage Performance for Detached Single-family Residential Buildings Table C405.5.2(1)
140—2010Standard Method of Test for the Evaluation of Building Energy
Analysis Computer Programs
C407.6.1
146—2006Testing and Rating Pool HeatersTable C404.2
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2859
Standard
reference
number
TitleReferenced
in code
section number
C 90—08Specification for Load-bearing Concrete Masonry Units Table C402.2
C 1371—04Standard Test Method for Determination of Emittance of Materials
Near Room Temperature Using Portable Emissometers
Table C402.2.1.1
C 1549—04Standard Test Method for Determination of Solar Reflectance Near
Ambient Temperature Using A Portable Solar Reflectometer
Table C405.2.1.1
D 1003—07e1Standard Test Method for Haze and Luminous Transmittance of
Transparent Plastics
C402.3.2.2
E 283—04Test Method for Determining the Rate of Air Leakage Through Exterior
Windows, Curtain Walls and Doors Under Specified Pressure
Differences Across the Specimen
Table C402.2.1.1, C402.4.1.2.2,
Table C402.4.3, C402.4.4, C402.4.8
E 408—71(2002)Test Methods for Total Normal Emittance of Surfaces Using
Inspection-meter Techniques
Table C402.2.1.1
E 779—03Standard Test Method for Determining Air Leakage Rate by Fan Pressurization C402.4.1.2.3
E 903—96Standard Test Method Solar Absorptance, Reflectance and
Transmittance of Materials Using Integrating Spheres (Withdrawn 2005)
Table C402.2.1.1
E 1677—05Standard Specification for an Air-retarder (AR) Material or System for
Low-rise Framed Building Walls
C402.4.1.2.2
E 1918—97Standard Test Method for Measuring Solar Reflectance of
Horizontal or Low-sloped Surfaces in the Field
Table C402.2.1.1
E 1980—(2001)Standard Practice for Calculating Solar Reflectance Index of
Horizontal and Low-sloped Opaque Surfaces
Table C402.2.1.1
E 2178—03Standard Test Method for Air Permanence of Building Materials C402.4.1.2.1
E 2357—05Standard Test Method for Determining Air Leakage of Air Barriers AssembliesC404.1.2.2
CSACanadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
reference
number
TitleReferenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
Table C402.4.3
CTICooling Technology Institute
2611 FM 1960 West, Suite A-101
Houston, TX 77068
Standard
reference
Number
TitleReferenced
in code
section number
ATC 105 (00)Acceptance Test Code for Water Cooling Tower Table C403.2.3(8)
STD 201—09Standard for Certification of Water Cooling Towers Thermal PerformancesTable C403.2.3(8)
DASMADoor and Access Systems Manufacturers Association
1300 Sumner Avenue
Cleveland, OH 44115-2851
Standard
reference
number
TitleReferenced
in code
section number
105—92 (R2004)Test Method for Thermal Transmittance and Air Infiltration of Garage Doors Table C402.4.3
DOEU.S. Department of Energy
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
TitleReferenced
in code
section number
10 CFR, Part 430—1998Energy Conservation Program for Consumer Products:
Test Procedures and Certification and Enforcement Requirement
for Plumbing Products; and Certification and Enforcement
Requirements for Residential Appliances; Final Rule
TableC403.2.3(4), TableC403.2.3(5),
Table C404.2, TableC406.2(4), TableC406.2(5)
10 CFR, Part 430, Subpart B,
Appendix N—1998
Uniform Test Method for Measuring the Energy Consumption of
Furnaces and Boilers
C202
10 CFR, Part 431—2004Energy Efficiency Program for Certain Commercial and Industrial
Equipment: Test Procedures and Efficiency Standards; Final Rules
TableC403.2.3(5), TableC406.2(5)
NAECA 87—(88)National Appliance Energy Conservation Act 1987
[(Public Law 100-12 (with Amendments of 1988-P.L. 100-357)]
Tables C403.2.3(1),(2),(4)
ICCInternational Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
IBC—12International Building Code® C201.3, C303.2, C402.4.4
IFC—12International Fire Code® C201.3
IFGC—12International Fuel Gas Code® C201.3
IMC—12International Mechanical Code® C403.2.5, C403.2.5.1, C403.2.6, C403.2.7, C403.2.7.1,
C403.2.7.1.1, C403.2.7.1.2, C403.2.7.1.3, C403.4.5, C408.2.2.1
IPC—12International Plumbing Code® C201.3
IESNAIlluminating Engineering Society of North America
120 Wall Street, 17th Floor
New York, NY 10005-4001
Standard
reference
number
TitleReferenced
in code
section number
ANSI/ASHRAE/IESNA
90.1—2007
Energy Standard for Buildings, Except Low-rise Residential Buildings C401.2, C401.2.1, C402.1.1,
Table C402.1.2, Table C402.2
ISOInternational Organization for Standardization
1, rue de Varembe, Case postale 56, CH-1211
Geneva, Switzerland
Standard
reference
number
TitleReferenced
in code
section number
ISO/AHRI/ASHRAE
13256-1 (2005)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 1: Water-to-air and Brine-to-air Heat Pumps
C403.2.3(2)
ISO/AHRI/ASHRAE
13256-2 (1998)
Water-Source Heat Pumps—Testing and Rating for Performance—
Part 2: Water-to-water and Brine-to-water Heat Pumps
C403.2.3(2)
NFRCNational Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt, MD 20770
Standard
reference
number
Title Referenced
in code
section number
100—2009Procedure for Determining Fenestration Products U-factors—Second Edition C303.1.2, C402.2.1
200—2009Procedure for Determining Fenestration Product Solar Heat Gain Coefficients
and Visible Transmittance at Normal Incidence—Second Edition
C303.1.3, C402.3.1.1
400—2009Procedure for Determining Fenestration Product Air Leakage—Second Edition Table C402.4.3
SMACNASheet Metal and Air Conditioning Contractors National Association, Inc.
4021 Lafayette Center Drive
Chantilly, VA 20151-1209
Standard
reference
number
TitleReferenced
in code
section number
SMACNA—85HVAC Air Duct Leakage Test Manual C403.2.7.1.3
ULUnderwriters Laboratories
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
Title Referenced
in code
section number
727—06Oil-fired Central Furnaces—with Revisions through April 2010Table C403.2.3(4), Table C406.2(4)
731—95Oil-fired Unit Heaters—with Revisions through April 2010 Table C403.2.3(4), Table C406.2(4)
US-FTCUnited States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
Standard
reference
number
TitleReferenced
in code
section number
CFR Title 16
(May 31, 2005)
R-value Rule C303.1.4
WDMAWindow and Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
Standard
reference
number
TitleReferenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
Table C402.4.3