Heads up:
There are no suggested sections in this chapter.
Heads up:
There are no amended sections in this chapter.
AMENDMENT
This section has been amended at the state or city level.
ANSI
American National Standards Institute
25 West 43rd Street
4th Floor
New York NY 10036
ANSI A13.1—2015
Scheme for the Identification of Piping Systems
704.1.2.2
ANSI FC 1—2012
Stationery Fuel Cell Power Systems
633.1
ANSI NGV 5.1—2015
Residential Fueling Appliances
413.4.1
LC 1/CSA 6.26—2013
Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST)
403.5.5
ANSI LC-4/CSA 6.32—2012
Press-connect Metallic Fittings for Use in Fuel Gas Distribution Systems
403.10.1, 403.10.2, 403.10.3
Z21.1—2010
Household Cooking Gas Appliances
623.1
Z21.5.1/CSA 7.1—2014
Gas Clothes Dryers—Volume I—Type 1 Clothes Dryers
613.1
Z21.5.2/CSA 7.2—2014
Gas Clothes Dryers—Volume II—Type 2 Clothes Dryers
613.1, 614.3
Z21.8—94 (R2002)
Installation of Domestic Gas Conversion Burners
619.1
Z21.10.1/CSA 4.1—2012
Gas Water Heaters—Volume I—Storage, Water Heaters with Input Ratings of 75,000 Btu per Hour or Less
624.1
Z21.10.3/CSA 4.3—2011
Gas Water Heaters—Volume III—Storage, Water Heaters with Input Ratings above 75,000 Btu per Hour, Circulating and Instantaneous
624.1
Z21.11.2—2011
Gas-fired Room Heaters—Volume II—Unvented Room Heaters
621.1
Z21.13/CSA 4.9—2011
Gas-fired Low-pressure Steam and Hot Water Boilers
631.1
Z21.15/CSA 9.1—2009
Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves
Table 409.1.1
Z21.19/CSA 1.4—02(R2007)
Refrigerators Using Gas (R1999) Fuel
625.1
Z21.24/CSA 6.10—2006
Connectors for Gas Appliances
411.1, 411.3
Z21.40.1/CGA 2.91—1996 (R2011)
Gas-fired Heat Activated Air Conditioning and Heat Pump Appliances
627.1
Z21.40.2/CGA 2.92—1996 (R2011)
Gas-fired Work Activated Air Conditioning and Heat Pump Appliances (Internal Combustion)
627.1
Z21.42—2014
Gas-fired Illuminating Appliances
628.1
Z21.47/CSA 2.3—2012
Gas-fired Central Furnaces
618.1
Z21.50/CSA 2.22—2016
Vented Gas Fireplaces
604.1
Z21.54—2009
Gas Hose Connectors for Portable Outdoor Gas-fired Appliances
411.1
Z21.56/CSA 4.7—2017
Gas-fired Pool Heaters
617.1
Z21.58/CSA 1.6—2013
Outdoor Cooking Gas Appliances
623.1
Z21.60/CSA 2.26—2012
Decorative Gas Appliances for Installation in Solid-fuel Burning Fireplaces
602.1
Z21.61—1983 (R2004)
Gas-fired Toilets
626.1
Z21.69/CSA 6.16—2009
Connectors for Movable Gas Appliances
411.1.1, 411.1.4
Z21.75/CSA 6.27—2007
Connectors for Outdoor Gas Appliances and Manufactured Homes
411.1, 411.2
Z21.80/CSA 6.22—2011
Line Pressure Regulators
410.1
Z21.84—2012
Manually Lighted, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces
602.1, 602.2
Z21.86/CSA 2.32—2008
Vented Gas-fired Space Heating Appliances
608.1, 609.1, 622.1
Z21.88/CSA 2.33—2016
Vented Gas Fireplace Heaters
605.1
Z21.91—2007
Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters
621.7.1
Z21.93/CSA 6.30—2013
Excess Flow Valves for Natural and LP Gas with Pressures up to 5 psig
410.4
Z21.97—2012
Outdoor Decorative Appliances
636.1
Z83.4/CSA 3.7—2012
Nonrecirculating Direct-gas-fired Industrial Air Heaters
611.1
Z83.8/CSA 2.6—2009
Gas Unit Heater, Gas Packaged Heater, Gas Utility Heaters and Gas-fired Duct Furnaces
610.1, 620.1
Z83.11/CSA 1.8—2013
Gas Food Service Equipment
623.1
Z83.18—2012
Recirculating Direct Gas-fired Industrial Air Heaters
612.1
Z83.19—2001(R2009)
Gas-fired High-intensity Infrared Heaters
630.1
Z83.20—2008
Gas-fired Low-intensity Infrared Heaters
630.1
ASME
American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016-5990
B1.20.1—2013
Pipe Threads, General Purpose (inch)
403.9
B16.1—2010
Gray Iron Pipe Flanges and Flanged Fittings, Class 25, 125 and 250
403.12.1
B16.5—2015
Pipe Flanges and Flanged Fittings: NPS 1/2 through NFPS 24 Metric/Inch Standard
403.12.2
B16.24—2016
Cast Copper Alloy Pipe Flanges and Flanged Fittings: Classes 150, 300, 600, 900, 1500 and 2500
403.12.3
B16.42—2016
Ductile Iron Pipe Flanges and Flanged Fittings, Classes 150 and 300
403.12.4
B16.47—2016
Large Diameter Steel Flanges: NPS 26 through NPS 60 Metric/Inch Standard
403.12.2
B16.33—2012
Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2)
Table 409.1.1
B16.44—2012
Manually Operated Metallic Gas Valves for Use in Aboveground Piping Systems up to 5 psi
Table 409.1.1
B36.10M—(R2015)
Welded and Seamless Wrought-steel Pipe
403.4.2
CSD-1—2016
Controls and Safety Devices for Automatically Fired Boilers
631.1
ASTM
ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959
A53/A53M—12
Specification for Pipe, Steel, Black and Hot Dipped Zinc-coated Welded and Seamless
403.4.2
A106/A106M—14
Specification for Seamless Carbon Steel Pipe for High-temperature Service
403.4.2
A254—12
Specification for Copper Brazed Steel Tubing
403.5.1
A268—10
Standard Specification for Seamless and Welded Ferritic and Martensitic Stainless Steel Tubing for General Service
403.5.2
A269—15
Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service
403.5.2
A312—15
Standard Specification for Seamless, Welded and Heavily Cold Worked Austenitic Stainless Steel Pipes
403.4.2
B88—14
Specification for Seamless Copper Water Tube
403.5.3
B210—12
Specification for Aluminum and Aluminum-alloy Drawn Seamless Tubes
403.5.4
B241/B241M—12e1
Specification for Aluminum and Aluminum-alloy, Seamless Pipe and Seamless Extruded Tube
403.4.4, 403.5.4
B280—13
Standard Specification for Seamless Copper Tube for Air-Conditioning and Refrigeration Field Service
403.5.3
C315—07(2011)
Specification for Clay Flue Liners and Chimney Pots
501.12
E136—16
Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C
202
F1973—13e1
Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA11) and Polyamide 12 (PA12) Fuel Gas Distribution Systems
404.17.2
F2945—15
Standard Specification for Polyamide 11 Gas Pressure Pipe, Tubing and Fittings
403.6
CGA
Compressed Gas Association
14501 George Carter Way, Suite 103
Chantilly VA 20151-2923
S-1.1—(2017)
Pressure Relief Device Standards—Part 1—Cylinders for Compressed Gases
703.3
S-1.2—(2009)
Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases
703.3
S-1.3—(2016)
Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases
703.3
CSA
CSA Group
8501 East Pleasant Valley Road
Cleveland OH 44131-5516
ANSI/CSA FC1—2014
Fuel Cell Technologies—Part 3-100; Stationary fuel cell power systems-Safety
633.1
CSA 8—93
Requirements for Gas-fired Log Lighters for Wood Burning Fireplaces
603.1
ANSI/CSA NGV 5.1—2015
Residential Fueling Appliances
413.4.1
DOTn
U.S.Department of Transportation
400 Seventh St. SW
Washington DC 20590
49 CFR, Parts 192.281(e) & 192.283 (b)—(2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards
403.6.1
ICC
International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington DC 20001
IBC—18
International Building Code®
102.2.1, 201.3, 301.10, 301.11, 301.12, 301.14, 302.1, 302.2, 305.6, 306.5.1, 306.6, 401.1.1, 412.6, 413.3, 413.3.1, 501.1, 501.3, 501.12, 501.15.4, 501.15.4.1, 609.3, 614.10, 633.1, 635.1, 706.2
IECC—18
International Energy Conservation Code®
301.2
IFC—18
International Fire Code®
201.3, 401.2, 412.1, 412.6, 412.7, 412.8, 413.1, 413.3, 413.3.1, 413.5, 413.9.2.5, 633.1, 701.1, 701.2, 703.2, 703.2.2, 703.3.8, 703.4, 703.5, 704.1.2, 704.3, 704.4, 706.2, 706.3, 707.1, 707.2, 708.1
IMC—18
International Mechanical Code®
101.2.5, 201.3, 301.1.1, 301.13, 304.11, 307.1, 307.5, 501.1, 614.2, 614.10, 618.3, 621.1, 624.1, 631.2, 632.1
IRC—18
International Residential Code®
101.2, 703.2.1
MSS
Manufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, NE
Vienna VA 22180
ANSI SP 58—2009
Pipe Hangers and Supports—Materials, Design and Manufacture
407.2
NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471
30A—18
Code for Motor Fuel Dispensing Facilities and Repair Garages
305.4, 305.10
37—18
Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines
616.1
51—18
Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes
414.1
54-2018
National Fuel Gas Code
82—14
Incinerators, Waste and Linen Handling Systems and Equipment
503.2.5, T503.4, 607.1
85—15
Boiler and Combustion Systems Hazards Code
631.1
88A—15
Parking Structures
305.9
409—16
Standard for the Aircraft Hangars
305.11
853—15
Installation of Stationary Fuel Cell Power Systems
633.1
UL
UL LLC
333 Pfingsten Road
Northbrook IL 60062
103—2010
Factory-built Chimneys, Residential Type and Building Heating Appliances— with Revisions through July 2012
506.1
127—2011
Factory-built Fireplaces—with Revisions through May 2015
621.7
441—2010
Gas Vents—with Revisions through June 2014
502.1
641—2010
Type L Low-temperature Venting Systems—with Revisions through June 2013
502.1
651—2011
Schedule 40 and 80 Rigid PVC Conduit and Fittings—with Revisions through May 2014
403.6.3
795—2011
Commercial-industrial Gas Heating Equipment— with Revisions through November 2013
610.1, 618.1, 631.1
959—2010
Medium Heat Appliance Factory-built Chimneys—with Revisions through June 2014
506.3
1618—09
Wall Protectors, Floor Protectors and Hearth Extensions—with Revisions through October 2015
308.2
1738—2010
Venting Systems for Gas Burning Appliances, Categories II, III and IV— with Revisions through November 2014
502.1, 503.4.1
1777—2007
Chimney Liners—with Revisions through October 2015
501.12, 501.15.4
2200—2012
Stationary Engine Generator Assemblies—with Revisions through July 2015
616.1