Chapter 84 Symbols for Vehicles Fueled by CNG, LPG, and LNG

AMENDMENT
This section has been amended at the state or city level.

Section 8400 Purpose and Scope

AMENDMENT
This section has been amended at the state or city level.
Purpose. The purpose of parts 7511.8400 to 7511.8440 is to prescribe the standard abbreviation and symbol required to be displayed on the exterior of any vehicle carrying liquefied petroleum gas fuel or natural gas in a concealed tank.

Scope. The scope of parts 7511.8400 to 7511.8440 is intended to be consistent with Minnesota Statutes, section 169.762.

Section 8410 Pressurized Flammable Gas

AMENDMENT
This section has been amended at the state or city level.
"Pressurized flammable gas" includes liquefied petroleum gas, compressed natural gas, and liquefied natural gas.

Section 8420 Warning Symbol Required

AMENDMENT
This section has been amended at the state or city level.
The marking required by Minnesota Statutes, section 169.762, must be displayed on the exterior of a vehicle carrying pressurized flammable gas in a concealed area, whether the gas is the primary fuel or secondary fuel.

Section 8430 Symbol Design

AMENDMENT
This section has been amended at the state or city level.
Design. The required warning symbol must be of a design illustrated as follows:



Specifications. The following specifications apply to each of the warning symbols:
  1. The symbol must be diamond-shaped, 21/2 inches in height, and four inches in width at its highest and widest points, respectively.
  2. The letters and border must be silver in color.
  3. The background must be black in color.
  4. The letters within the symbol must be a minimum of one inch in height.
  5. The entire symbol, including letters, background, and border, must be made of reflectorized material and not fade or wash away when exposed to weather or other adverse elements.

Section 8440 Symbol Placement

AMENDMENT
This section has been amended at the state or city level.
A minimum of two warning symbols is required to be displayed. The warning symbols must be displayed in the places specified in Item A. If the symbols cannot be clearly displayed or effectively applied to those locations, they may be displayed in the places specified in Item B. Display at least two symbols as follows:
  1. one warning symbol on the extreme left (driver's) side of the rear-facing portion of the rear bumper, and one warning symbol on the extreme right (passenger) side of the front-facing portion of the front bumper; or
  2. One warning symbol at least 12 inches, but not more than 30 inches, above the ground on the rear of the vehicle near the left (driver's) side and one warning symbol at least 12 inches, but not more than 30 inches, above the ground on the front of the vehicle near the right (passenger) side.