Heads up: There are no amended sections in this chapter.
User note:
About this chapter: Chapter 6 lists the full title, edition year and address of the promulgator for all standards that are referenced in the code. The section numbers in which the standards are referenced are also listed.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 107.
AAMA
American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg IL60173-4268
AAMA/WDMA/CSA 101/I.S.2/A C440—17
North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights
AHAM
Association of Home Appliance Manufacturers
1111 19th Street NW, Suite 402
Washington DC20036
ANSI/AHAM RAC-1—2008
Room Air Conditioners
AHAM HRF-1—2016
Energy, Performance and Capacity of Household Refrigerators, Refrigerator-Freezers and Freezers
Table C403.10.1
AHRI
Air-Conditioning, Heating, & Refrigeration Institute
2111 Wilson Blvd, Suite 500
Arlington VA22201
ISO/AHRI/ASHRAE 13256-1 (1998 RA2014)
Water-to-Air and Brine-to-Air Heat Pumps—Testing and Rating for Performance
ISO/AHRI/ASHRAE 13256-2 (1998 RA2014)
Water-to-Water and Brine-to-Water Heat Pumps —Testing and Rating for Performance
210/240—2016
Performance Rating of Unitary Air-conditioning and Air-source Heat Pump Equipment
310/380—2014 (CSA-C744-04)
Standard for Packaged Terminal Air Conditioners and Heat Pumps
340/360—2015
Performance Rating of Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment
365(I-P)—2009
Commercial and Industrial Unitary Air-conditioning Condensing Units
390 (I-P)—2015
Performance Rating of Single Package Vertical Air-conditioners and Heat Pumps
400 (I-P)—2015
Performance Rating of Liquid to Liquid Heat Exchangers
440—2008
Performance Rating of Room Fan Coils—with Addendum 1
460—2005
Performance Rating of Remote Mechanical-draft Air-cooled Refrigerant Condensers
550/590 (I-P)—2015
Performance Rating of Water-chilling and Heat Pump Water-heating Packages Using the Vapor Compression Cycle
560—00
Absorption Water Chilling and Water Heating Packages
1160 (I-P) —2014
Performance Rating of Heat Pump Pool Heaters
1200 (I-P)—2013
Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets
AMCA
Air Movement and Control Association International
30 West University Drive
Arlington Heights IL60004-1806
205—12
Energy Efficiency Classification for Fans
220—08 (R2012)
Laboratory Methods of Testing Air Curtain Units for Aerodynamic Performance Rating
500D—12
Laboratory Methods for Testing Dampers for Rating
ANSI
American National Standards Institute
25 West 43rd Street, 4th Floor
New York NY10036
Z21.10.3/CSA 4.3—11
Gas Water Heaters, Volume III—Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous
Z21.47/CSA 2.3—12
Gas-fired Central Furnaces
Z83.8/CSA 2.6—09
Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces
APSP
The Association of Pool & Spa Professionals
2111 Eisenhower Avenue, Suite 580
Alexandria VA22314
14—2014
American National Standard for Portable Electric Spa Energy Efficiency
ASHRAE
ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329
ASHRAE 127-2007
Method of Testing for Rating Computer
ANSI/ASHRAE/ACCA Standard 183—2007 (RA2014)
Peak Cooling and Heating Load Calculations in Buildings, Except Low-rise Residential Buildings
ASHRAE—2016
ASHRAE HVAC Systems and Equipment Handbook
ISO/AHRI/ASHRAE 13256-1 (1998 RA2014)
Water-to-Air and Brine-to-Air Heat Pumps—Testing and Rating for Performance
ISO/AHRI/ASHRAE 13256-2 (1998 RA2014)
Water-to-Water and Brine-to-Water Heat Pumps—Testing and Rating for Performance
55—2013
Thermal Environmental Conditions for Human Occupancy
Table C407.5.1
90.1—2016
Energy Standard for Buildings Except Low-rise Residential Buildings
140—2014
Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs
146—2011
Testing and Rating Pool Heaters
ASME
American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016-5990
ASME A17.1—2016/CSA B44—16
Safety Code for Elevators and Escalators
ASTM
ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959
C90—14
Specification for Load-bearing Concrete Masonry Units
C1363—11
Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
C1371—15
Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers
C1549—09(2014)
Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer
D1003—13
Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics
E283—04(2012)
Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen
E408—13
Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques
E779—10
Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
E903—12
Standard Test Method Solar Absorptance, Reflectance and Transmittance of Materials Using Integrating Spheres (Withdrawn 2005)
E1677—11
Specification for Air Barrier (AB) Material or Systems for Low-rise Framed Building Walls
E1827—11
Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door
E1918—06(2015)
Standard Test Method for Measuring Solar Reflectance of Horizontal or Low-sloped Surfaces in the Field
E1980—11
Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces
E2178—13
Standard Test Method for Air Permanence of Building Materials
E2357—11
Standard Test Method for Determining Air Leakage of Air Barriers Assemblies
CRRC
Cool Roof Rating Council
449 15th Street, Suite 400
Oakland CA94612
ANSI/CRRC-S100—2016
Standard Test Methods for Determining Radiative Properties of Materials
CSA
CSA Group
8501 East Pleasant Valley Road
Cleveland OH44131-5516
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights
CSA B55.1—2015
Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units
CSA B55.2—2015
Drain Water Heat Recovery Units
CTI
Cooling Technology Institute
P. O. Box 681807
Houston TX77268
ATC 105 (00)
Acceptance Test Code for Water Cooling Tower
ATC 105S—11
Acceptance Test Code for Closed Circuit Cooling Towers
ATC 106—11
Acceptance Test for Mechanical Draft Evaporative Vapor Condensers
STD 201—11
Standard for Certification of Water Cooling Towers Thermal Performances
CTI STD 201 RS(15)
Performance Rating of Evaporative Heat Rejection Equipment
DASMA
Door & Access Systems Manufacturers Association, International
1300 Sumner Avenue
Cleveland OH44115-2851
105—2016
Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors
DOE
U.S. Department of Energy
c/o Superintendent of Documents
1000 Independence Avenue SW
Washington DC20585
10 CFR, Part 430—2015
Energy Conservation Program for Consumer Products: Test Procedures and Certification and Enforcement Requirement for Plumbing Products; and Certification and Enforcement Requirements for Residential Appliances; Final Rule
10 CFR, Part 430, Subpart B, Appendix N—(2015)
Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers
C202
10 CFR, Part 431—2015
Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures and Efficiency Standards; Final Rules
10 CFR 431 Subpart B App B
Uniform Test Method for Measuring Nominal Full Load Efficiency of Electric Motors
NAECA 87—(88)
National Appliance Energy Conservation Act 1987 [Public Law 100-12 (with Amendments of 1988-P.L. 100-357)]
ICC
International Code Council, Inc.
500 New Jersey Avenue NW
6th Floor
Washington DC 20001
IPC—18
International Plumbing Code®
IPMC—18
International Property Maintenance Code®
IPSDC—18
International Private Sewage Disposal Code®
IEEE
Institute of Electrical and Electronic Engineers
3 Park Avenue, 17th Floor
New York NY10016
IEEE 515.1—2012
IEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Commercial Applications
IES
Illuminating Engineering Society
120 Wall Street, 17th Floor
New York NY10005-4001
Energy Standard for Buildings, Except Low-rise Residential Buildings
ISO
International Organization for Standardization
Chemin de Blandonnet 8, CP 401, 1214 Vernier
Geneva Switzerland
ISO/AHRI/ASHRAE 13256-1(1998 RA2014)
Water-to-Air and Brine-to-Air Heat Pumps -Testing and Rating for Performance
ISO/AHRI/ASHRAE 13256-2(1998 RA2014)
Water-to-Water and Brine-to-Water Heat Pumps -Testing and Rating for Performance
NEMA
National Electrical Manufacturers Association
1300 North 17th Street, Suite 900
Rosslyn VA22209
MG1—2014
Motors and Generators
C202
NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471
70—17
National Electrical Code
NFRC
National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt MD20770
100—2017
Procedure for Determining Fenestration Products U-factors
200—2017
Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence
400—2017
Procedure for Determining Fenestration Product Air Leakage
SMACNA
Sheet Metal and Air Conditioning Contractors' National Association, Inc.
4021 Lafayette Center Drive
Chantilly VA20151-1219
SMACNA—2012
HVAC Air Duct Leakage Test Manual Second Edition
UL
UL LLC
333 Pfingsten Road
Northbrook IL 60062-2096
710—12
Exhaust Hoods for Commercial Cooking Equipment—with Revisions through November 2013
727—06
Oil-fired Central Furnaces—with Revisions through October 2013
731—95
Oil-fired Unit Heaters—with Revisions through October 2013
1784—01
Air Leakage Tests of Door Assemblies—with Revisions through February 2015
US-FTC
United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington DC20580
CFR Title 16 (2015)
R-value Rule
WDMA
Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington DC20036-3309
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights