Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

AA Aluminum Association
1525 Wilson Boulevard, Suite 600
Arlington, VA 22209
Standard
reference
number
Title Referenced
in code
section number
ADM1 - 2015 Aluminum Design Manual: Part 1 - A Specification for Aluminum Structures 1604.3.5, 2002.1
ASM35 - 00 Aluminum Sheet Metal Work in Building Construction (Fourth Edition) 2002.1
     
AAMA American Architectural Manufacturer s Association
1827 Waldon Office Square, Suite 550
Schaumburg, IL 60173
Standard
reference
number
Title Referenced
in code
section number
1402 - 09 Standard Specifications for Aluminum Siding, Soffit and Fascia 1404.5.1
AAMA/WDMA/CSA
101/I.S.2/A440-11
North American Fenestration Standard/Specifications for
   Windows, Doors and Skylights
1709.5.1, 2405.5
     
ACI American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
Title Referenced
in code
section number
216.1 - 14 Code Requirements for Determining Fire Resistance of Concrete
   and Masonry Construction Assemblies
Table 721.1(2), 722.1
318 - 14 Building Code Requirements for Structural Concrete 1604.3.2, 1615.3.1, 1615.4.1,
1704.5, Table 1705.3, 1705.3.2,
1705.12.1, 1808.8.2, Table 1808.8.2, 1808.8.5, 1808.8.6,
1810.1.3, 1810.2.4.1, 1810.3.2.1.1, 1810.3.2.1.2 , 1810.3.8.3.1, 1810.3.8.3.3,
1810.3.9.4.2.1, 1810.3.9.4.2.2, 1810.3.10.1, 1810.3.11.1, 1901.2, 1901.3,
1902.1, 1903.1, 1904.1, 1904.2, 1905.1, 1905.1.1, 1905.1.2,
1905.1.3, 1905.1.4, 1905.1.5, 1905.1.6, 1905.1.7, 1905.1.8
1906.1, 2108.3, 2206.1
530 - 13 Building Code Requirements for Masonry Structures 1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4,
1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9
2101.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4,
2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1,
2109.2, 2109.2.1, 2109.3, 2110.1
530.1- 13 Specifications for Masonry Structures 1405.6.1, 1705.4, 1807.1.6.3, 2 I 03.1, 2103. 2.1,
2103.3, 2103.4, 2105.1
     
AISC American Institute of Steel
Construction One East Wacker Drive, Suite 700
Chicago, IL 60601 - 18021
Standard
reference
number
Title Referenced
in code
section number
341 - 10 Seismic Provisions for Structural Steel Buildings 1613.4.1, 1705.12.1.1, 1705.12.1.2,
1705.13.1.1, 1705.13.1.2, 2205.2.1.1,
2205.2.1.2, 2205.2.2, 2206.2.1
360 - 10 Specification for Structural Steel Buildings
722.5.2.2.1, 1604.3.3, 1705.2.1,
2203.1, 2203.2, 2205.1, 2205.2.1.1, 2206.1
     
AISI American Iron and Steel Institute
25 Massachusetts A venue, NW Suite 800
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
AISI S100 - 12 North American Specification for the Design of Cold-formed Steel
   Structural Members, 2012

1604.3.3, 1905.1.8, 2203.1, 2203.2,
2210.1, 2210.2, 2211.2, 2211.4, 2211.6
AISI S110 - 07/
S1-09 (2012)
Standard for Seismic Design of Cold-Formed Steel Structural Systems-Special    Moment Frames, 2007 with Supplement 1, dated 2009    (Reaffirmed 2012) 210.2
AISI S200 -12 North American Standard for Cold-Formed Steel Framing-General Provisions, 2012 2203.1, 2203.2,
2211.1, Table 2603.12.1,
Table 2603.12.2
AISI S210 - 07(2012) North American Standard for Cold-Formed Steel Framing-Floor
   and Roof System Design, 2007 (Reaffirmed 2012)

2211.5
AISI S211 - 07/
S1 -12(2012)
North American Standard for Cold-Formed Steel Framing-Wall Stud Design, 2007    including Supplement 1, dated 2012 (Reaffirmed 2012) 2211.4
AISI S212 - 07(2012) North American Standard for Cold-Formed Steel Framing-Header Design, 2007,    (Reaffirmed 2012) 2211.2
AISI S213 - 07/
S1-09 (2012)
North American Standard for Cold-Formed Steel Framing-Lateral
   Design, 2007, with Supplement 1, dated 2009, (Reaffirmed 2012)
2211.6
AISI S214 - 12 North American Standard for Cold-formed Steel Framing-Truss Design, 2012 2211.3, 2211.3.1, 2211.3.2
AISI S220 - 11 North American Standard for Cold-formed Steel Framing-Nonstructural Members 2203.1, 2203.2,
2211.1, Table 2506.2, Table 2507.2
AISI S230 - 07/
S3 -12(2012)
Standard for Cold-formed Steel Framing-Prescriptive Method for One- and Two-    family Dwellings, 2007, with Supplement 3, dated 2012 (Reaffirmed 2012)
1609.1.1,
1609.1.1.1, 2211.7
     
ALI Automotive Lift Institute
P.O. Box 85
Courtland, NY 13045
Standard
reference
number
Title Referenced
in code
section number
ALI ALCTV - 2011 Standard for Automotive Lifts-Safety Requirements for
   Construction, Testing and Validation (ANSI)

3001.2
     
AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
Standard
reference
number
Title Referenced
in code
section number
540 - 08 Test Method for Louvers Impacted by Wind Borne Debris 1609.1.2.1
     
ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A13.1 - 2007 Scheme for the Identification of Piping Systems 415.11.6.5
A108.1A - 99 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar 2103.2.3
A108.1B - 99 Installation of Ceramic Tile, quarry Tile on a Cured Portland
   Cement Mortar Setting Bed with Dry-set or Latex-Portland Mortar

2103.2.3
A108.4 - 99 Installation of Ceramic Tile with Organic Adhesives or
   Water-cleanable Tile-setting Epoxy Adhesive

2103.2.3.6
A108.5 - 99 Installation of Ceramic Tile with Dry-set Portland Cement Mortar
   or Latex-Portland Cement Mortar

2103.2.3.1, 2103.2.3.2
A108.6 - 99 Installation of Ceramic Tile with Chemical-resistant, Water
   Cleanable Tile-setting and -grouting Epoxy

2103.2.3.3
A108.8 - 99 Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout 2103.2.3.4
A108.9 - 99 Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout 2103.2.3.5
A108.10 - 99 Installation of Grout in Tilework 2103.2.3.7
A118.1 - 99 American National Standard Specifications for Dry-set Portland Cement Mortar 2103.2.3.1
A118.3 - 99 American National Standard Specifications for Chemical-resistant, Water-cleanable
   Tile-setting and -grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive

2103.2.3.3
A118.4 - 99 American National Standard Specifications for Latex-Portland Cement Mortar 2103.2.3.2, 2103.3.2.4
A118.5 - 99 American National Standard Specifications for
   Chemical Resistant Furan Mortar and Grouts for Tile Installation

2103.2.3.4
A118.6 - 99 American National Standard Specifications for Cement Grouts for Tile Installation 2103.2.3.7
A118.8 - 99 American National Standard Specifications for Modified Epoxy Emulsion    Mortar/Grout 2103.2.3.5
A136.1 - 99 American National Standard Specifications for
   Organic Adhesives for Installation of Ceramic Tile

2103.2.3.6
A137.1 - 12 American National Standard Specifications for Ceramic Tile 202
ANSI/A 190.1 - 12 Structural Glued Laminated Timber 2303.1.3, 2306.1
Z 97.1 - 14 Safety Glazing Materials Used in Buildings-Safety Performance
   Specifications and Methods of Test

2406.1.2, 2406.2, Table 2406.2(2), 2406.3.1,
2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.2, 2409.3, 2409.4.1
     
APA APA - Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
Standard
reference
number
Title Referenced
in code
section number
ANSI/A 190.1 - 12 Structural Glued Laminated Timber 2303.1.3, 2306.1
ANSI/APA PRP 210 - 08 Standard for Performance-Rated Engineered Wood Siding 2303.1.5, 2304.7, 2306.3, Table 2306.3(1)
ANSI/APA PRR 410 - 11 Standard for Performance-Rated Engineered Wood Rim Boards 2303.1.13
APA PDS - 12 Panel Design Specification 2306.1
APA PDS
Supplement 1 - 12
Design and Fabrication of Plywood Curved Panels (revised 2013) 2306.1
APA PDS
Supplement 2 - 12
Design and Fabrication of Plywood-lumber Beams (revised 2013) 2306.1
APA PDS
Supplement 3 - 12
Design and Fabrication of Plywood Stressed-skin Panels (revised 2013) 2306.1
APA PDS
Supplement 4 - 12
Design and Fabrication of Plywood Sandwich Panels (revised 2013) 2306.1
APA PDS
Supplement 5 - 12
Design and Fabrication of All-plywood Beams (revised 2013) 2306.1
APA PRG 320 - 11 Standard for Performance-Rated Cross-Laminated Timber 2303.1.4
EWS R540 - 12 Builders Tips: Proper Storage and Handling of Glulam Beams 2306.1
EWS S475 - 07 Glued Laminated Beam Design Tables 2306.1
EWS S560 - 10 Field Notching and Drilling of Glued Laminated Timber Beams 2306.1
EWS T300 - 07 Glulam Connection Details 2306.1
EWS X440 - 08 Product Guide-Glulam 2306.1
EWS X450 - 01 Glulam in Residential Construction-Western Edition 2306.1
     
ASABE American Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph, MI 49085
Standard
reference
number
Title Referenced
in code
section number
EP 484.2 June
1998 (R2008)
Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings 2306.1
EP 486.2 OCT 2012 Shallow-post and Pier Foundation Design 2306.1
EP 559.1 W/Corr.1
AUG 2010
Design Requirements and Bending Properties for Mechanically
   Laminated Wood Assemblies

2306.1
     
ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191 - 4400
Standard
reference
number
Title Referenced
in code
section number
5 - 13 Building Code Requirements for Masonry Structures 1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4,
1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9,
2101.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4,
2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2,
2109.2.1, 2109.3, 2110.1
6 - 13 Specification for Masonry Structures 1405.6.1, 1705.4, 1807.1.6.3, 2103.1, 2103.2.1,
2103.3, 2103.4, 2104.1, 2105.1
7 - 10 Minimum Design Loads for Buildings and Other Structures with
   Supplement No. 1
202, Table 1504.8, 1602.1, 1604.3,
Table 1604.5, 1604.8.2, 1604.10, 1605.1, 1605.2.1, 1605.3.1, 1605.3.1.2,
1605.3.2, 1605.3.2.1,1607.8.1, 1607.8.1.1, 1607.8.1.2, 1607.8.3, 1607.12.1,
1608.1, 1608.2, 1608.3, 1609.1.1, 1609.1.2, 1609.3, 1609.5.1, 1609.5.3, 1609.6,
1609.6.1, 1609.6.1.1, 1609.6.2, Table 1609.6.2, 1609.6.3, 1609.6.4.1, 1609.6.4.2,
1609.6.4.4.1, 1611.2, 1612.4, 1613.1, 1613.3.2, Table 1613.3.3(1), Table 1613.3.3(2),
1613.3.5, 1613.3.5.1, 1613.3.5.2, 1613.4, 1613.4.1, 1613.5.1, 1613.6, 1614.1, 1704.6.1, 1705.12,
1705.12.4, 1705.13.2, 1705.13.3, 1705.13.4, 1803.5.12, 1808.3.1, 1810.3.6.1, 1810.3.9.4, 1810.3.11.2,
1810.3.12, 1905.1.1, 1905.1.2, 1905.1.8, 2205.2.1.1, 2205.2.1.2, 2205.2.2, 2206.2.1, 2209.1, 2210.2,
2304.6.1, 2404.1, 2505.1, 2505.2, 2506.2.1
8 - 14 Standard Specification for the Design of Cold-formed
   Stainless Steel Structural Members
1604.3.3, 2210.1, 2210.2
19 - 09 Structural Applications of Steel Cables for Buildings 2208.1, 2208.2
24 - 14 Flood Resist ant Design and Construction 1203.4.2, 1612.4, 1612.5,
2702.1.7, 3001.2
29 - 14 Standard Calculation Methods for Structural Fire Protection 722.1
32 - 01 Design and Construction of Frost Protected Shallow Foundations 1809.5
49 - 07 Wind Tunnel Testing for Buildings and Other Structures 1609.1.1
55 - 10 Tensile Membrane Structures 3102.1.1
     
ASME American Society of Mechanical Engineers
Two Park A venue
New York, NY 10016 - 5990
Standard
reference
number
Title Referenced
in code
section number
ASME/A17.1 - 13
CSA B44 - 2013

Safety Code for Elevators and Escalators

907.3.3, 911.1.5, 1009.4, 1607.9.1, 3001.2, 3001.4,
3002.5, 3003.2, 3007.1, 3008.1.3, 3008.7.1
A17.7 - 2007/
CSA B44 - 07
Performance-Based Safety Code for Elevators and Escalators 3001.2
A18.11 - 2008 Safety Standard for Platform Lifts and Stairway Chairlifts 1109.8
A90.1 - 09 Safety Standard for Belt Manlifts 3001.2
B16.18 - 2012 Cast Copper Alloy Solder Joint Pressure Fittings 909.13.1
B16.22 - 2001(R2010) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 909.13.1
B20.1 - 2009 Safety Standard for Conveyors and Related Equipment 3001.2, 3004.3
B31.3 - 2012 Process Piping 415.11.6
     
ASSE American Society of Safety Engineers
1800 East Oakton Street
Des Plaines, IL 60018
Standard
reference
number
Title Referenced
in code
section number
ANSU/ASSE Z359.1 - 2007 Safety Requirements for Personal Fall Arrest Systems,
   Subsystems and Components, Part of the Fall Protection Code

1015.6, 1015.7
     
ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428 - 2959
Standard
reference
number
Title Referenced
in code
section number
A6/A6M - 11 Standard Specification for General Requirements for Rolled Structural
   Steel Bars, Plates, Shapes and Sheet

1810.3.2.3, 1810.3.5.3.1, 1810.3.5.3.3
A36/A36M - 08 Specification for Carbon Structural Steel 1810.3.2.3
A153/A153M - 09 Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware 2304.10.5
A240/A240M - 13A Standard Specification for Chromium and Chromium-nickel Stainless Steel    Plate,Sheet and Strip for Pressure Vessels and for General Applications
Table 1507.4.3(1)
A252 - 10 Specification for Welded and Seamless Steel Pipe Piles 1810.3.2.3
A283/A283M - 12A Specification for Low and Intermediate Tensile Strength Carbon Steel Plates 1810.3.2.3
A416/A416M - 12A Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete 1810.3.2.2
A463/A463M - 10 Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process Table 1507.4.3(2)
A572/A572M - 12A Specification for High-strength Low-alloy Columbium-Vanadium Structural Steel 1810.3.2.3
A588/A588M - 10 Specification for High-strength Low-alloy Structural Steel with
   50 ksi (345 MPa) Minimum Yield Point with Atmospheric Corrosion Resistance

1810.3.2.3
A615/A615M - 12 Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement 1704.5, 1810.3.10.2
A653/A653M - 11 Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron
   Alloy-coated Galvannealed by the Hot-dip Process

Table 1507.4.3(1),
Table 1507.4.3(2), 2304.10.5.1
A690/A690M - 07(2012) Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel    H-piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Marine    Environments

1810.3.2.3
A706/A706M - 09b Specification for Low-alloy Steel Deformed and Plain Bars
   for Concrete Reinforcement

1704.5, 2107.4, 2108.3
A722/A722M - 12 Specification for Uncoated High-strength Steel Bar for Prestressing Concrete 1810.3.10.2
A755/A755M - 2011 Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted    by the Coil-coating Process for Exterior Exposed Building Products

Table 1507.4.3(1), Table 1507.4.3(2)
A792/A792M -10 Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated
   by the Hot-dip Process

Table 1507.4.3(1), Table 1507.4.3(2)
A875/A875M - 13 Standard Specification for Steel Sheet Zinc-5 percent,
   Aluminum Alloy-coated by the Hot-dip Process

Table 1507.4.3(2)
A924/A924M - 13 Standard Specification for General Requirements for Steel
   Sheet, Metallic-coated by the Hot-dip Process

Table 1507.4.3(1)
B42 - 10 Specification for Seamless Copper Pipe, Standard Sizes 909.13.1
B43 - 09 Specification for Seamless Red Brass Pipe, Standard Sizes 909.13.1
B68 - 11 Specification for Seamless Copper Tube, Bright Annealed (Metric) 909.13.1
B88 - 09 Specification for Seamless Copper Water Tube 909.13.1
B101 - 12 Specification for Lead-coated Copper Sheet and Strip
   for Building Construction

1404.5.3, Table 1507.2.9.2, Table 1507.4.3(1)
B209 - 10 Specification for Aluminum and Aluminum Alloy Steel and Plate Table 1507.4.3(1)
B251 - 10 Specification for General Requirements for Wrought Seamless
   Copper and Copper-alloy Tube

909.13.1
B280 - 08 Specification for Seamless Copper Tube for Air Conditioning
   and Refrigeration Field Service

909.13.1
B370 - 12 Specification for Copper Sheet and Strip for
   Building Construction

1404.5.2, Table 1507.2.9.2, Table 1507.4.3(1)
B695 - 04(2009) Standard Specification for Coatings of Zinc Mechanically
   Deposited on Iron and Steel Strip for Building Construction

2304.10.5.1, 2304.10.5.3
C5 - 10 Specification for Quicklime for Structural Purposes Table 2507.2
C22/C22M - 00(2010) Specification for Gypsum Table 2506.2
C27 - 98(2008) Specification for Classification of Fireclay and High-alumina Refractory Brick 2111.6
C28/C28M - 10 Specification for Gypsum Plasters Table 2507.2
C31/C31M - 12 Practice for Making and Curing Concrete Test Specimens in the Field Table 1705.3
C33/C33M - 13 Specification for Concrete Aggregates 722.3.1.4, 722.4.1.1.3
C35/C35M - 1995(2009) Specification for Inorganic Aggregates for Use in Gypsum Plaster Table 2507.2
C55 - 2011 Specification for Concrete Building Brick Table 722.3.2
C59/C59M - 00 (2011) Specification for Gypsum Casting Plaster and Molding Plaster Table 250
C61/C61M - 00 (2011) Specification for Gypsum Keene's Cement Table 2507.2
C62 - 13 Standard Specification for Building Brick
   (Solid Masonry Units Made from Clay or Shale)

1807.1.6.3
C67 - 13 Test Methods of Sampling and Testing Brick and Structural Clay Tile 721.4.1.1.1, 2109.3.1.
C73 - 10 Specification for Calcium Silicate Brick (Sand-lime Brick) Table 722.3.2
C90 - 13 Specification for Load bearing Concrete Masonry Units Table 722.3.2, 1807.1.6.3
C91 - 12 Specification for Masonry Cement Table 2507.2
C94/C94M - 13 Specification for Ready-Mixed Concrete 110.3.1
C140 - 13 Test Method Sampling and Testing Concrete Masonry Units and Related Units 722.3.1.2
C150 - 12 Specification for Portland Cement 1903.1, Table 2507.2
C172/C172M - 10 Practice for Sampling Freshly Mixed Concrete Table 1705.3
C199 - 84 (2011) Test Method for Pier Test for Refractory Mortars 2111.6, 2111.9, 2113.12
C206 - 13 Specification for Finishing Hydrated Lime Table 2507.2
C208 - 12 Specification for Cellulosic Fiber Insulating Board Table 1508.2, 2303.1.6
C216 - 13 Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) 1807.1.6.3
C270 - 12a Specification for Mortar for Unit Masonry 2103.3.2.4
C315 - 07(2011) Specification for Clay Flue Liners and Chimney Pots 2111.9, 2113.11.1, Table 2113.16(1)
C317/C317M - 00(2010) Specification for Gypsum Concrete 2514.1
C330/C330M - 2009 Specification for Lightweight Aggregates for Structural Concrete 202
C331/C331M - 2010 Specification for Lightweight Aggregates for Concrete Masonry Units 722.3.1.4, 722.4.1.1.3
C406/C406M - 2010 Specification for Roofing Slate 1507.7.5
C472 - 99 (2009) Specification for Standard Test Methods for Physical Testing
   of Gypsum, Gypsum Plasters and Gypsum Concrete

Table 2506.2
C473 - 12 Test Method for Physical Testing of Gypsum Panel Products Table 2506.2
C474 - 13 Test Methods for Joint Treatment Materials for Gypsum Board Construction Table 2506.2
C475/C475M - 12 Specification for Joint Compound and Joint Tape for Finishing Gypsum Board Table 2506.2
C514 - 04(2009)e1 Specification for Nails for the Application of Gypsum Board Table 721.1 (2), Table 721.1 (3),
Table 2306.7, Table 2506.2
C516 - 08 Specifications for Vermiculite Loose Fill Thermal Insulation 722.3.1.4, 722.4.1.1.3
C547 - 12 Specification for Mineral Fiber Pipe Insulation Table 721.1(2), Table 721.1(3)
C549 - 06(2012) Specification for Perlite Loose Fill Insulation 722.3.1.4, 722.4.1.1.3
C552 - 12b Standard Specification for Cellular Glass Thermal Insulation Table 1508.2
C557 - 03(2009)e01 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing Table 2506.2
C578 - 12b Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation
Table 1508.2, 2603.10,
Table 2603.12.1, Table 2603.12.2
C587 - 04(2009) Specification for Gypsum Veneer Plaster Table 2507.2
C595/C595 - 13 Specification for Blended Hydraulic Cements 1903.1, Table 2507.2
C631 - 09 Specification for Bonding Compounds for Interior Gypsum Plastering Table 2507.2
C635/C635M - 13 Specification for the Manufacture, Performance and Testing of
   Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings

808.1.1, 2506.2.1
C636/C636M - 08 Practice for Installation of Metal Ceiling Suspension
   Systems for Acoustical Tile and Lay-in Panels

808.1.1.1
C645 - 13 Specification for Nonstructural Steel Framing Members Table 2506.2, Table 2507.2
C652 - 13 Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale) 1807.1.6.3
C726 - 12 Standard Specification for Mineral Roof Insulation Board Table 1508.2
C728 - 05(2013) Standard Specification for Perlite Thermal Insulation Board Table 1508.2
C744 - 11 Specification for Prefaced Concrete and Calcium Silicate Masonry Units Table 722.3.2
C754 - 11 Specification for Installation of Steel Framing Members
   to Receive Screw-attached Gypsum Panel Products

Table 2508.1, Table 2511.1.1
C836/C836M - 12 Specification for High-solids Content, Cold Liquid-applied
   Elastomeric Waterproofing Membrane for Use with Separate Wearing Course

1507.15.2
C840 - 11 Specification for Application and Finishing of Gypsum Board Table 2508.1, 2509.2
C841 - 03(2008)E1 Specification for Installation of Interior Lathing and Furring Table 2508.1, Table 2511.1.1
C842 - 05(2010)E1 Specification for Application of lnterior Gypsum Plaster Table 2511.1.1, 2511.3, 2511.4
C843 - 99 (2012) Specification for Application of Gypsum Veneer Plaster Table 2511.1.1
C844 - 04(2010) Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster Table 2508.1
C847 - 12 Specification for Metal Lath Table 2507.2
C887 - 05(2010) Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar 1805.2.2, 2103.2.2
C897 - 05(2009) Specification for Aggregate for Job-Mixed Portland Cement-based Plaster Table 2507.2
C920 - 11 Standard for Specification for Elastomeric Joint Sealants Table 2506.2
C926 - 13 Specification for Application of Portland Cement-based Plaster 2109.3.4.8, 2510.3,
Table 2511.1.1, 2511.3, 251 1.4, 2512.1,
2512.1.2, 2512.2, 2512.6, 2512.8.2, 2512.9, 2513.7
C932 - 06(2013) Specification for Surface-applied Bonding Compounds for Exterior Plastering Table 2507.2
C933 - 13 Specification for Welded Wire Lath Table 2507.2
C946 - 10 Specification for Construction of Dry-stacked, Surface-bonded Walls 2103.2.2, 2109.2.2
C954 - 11 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or    Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to 0.112 inch (2.84    mm) in Thickness

Table 2506.2, Table 2507.2
C955 - 11C Standard Specification for Load-bearing Transverse and Axial Steel Studs, Runners    Tracks, and Bracing or Bridging, for Screw Application of Gypsum Panel Products    and Metal Plaster Bases

Table 2506.2, Table 2507.2
C956 - 04(2010) Specification for Installation of Cast-in-place Reinforced Gypsum Concrete 2514.1
C957 - 10 Specification for High-solids Content, Cold Liquid-applied
   Elastomeric Waterproofing Membrane with Integral Wearing Surface

1507.15.2
C1002 - 07 Specification for Steel Self-piercing Tapping Screws for the Application of
   Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs

Table 2506.2, Table 2507.2
C1007 - 11a Specification for Installation of Load Bearing (Transverse and
   Axial) Steel Studs and Related Accessories

Table 2508.1, Table 2511.1.1
C1029 - 13 Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation 1507.14.2
C1032 - 06(2011) Specification for Woven Wire Plaster Base Table 2507.2
C1047 - 10A Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base Table 2506.2, Table 2507.2
C1063 - 12D Specification for Installation of Lathing and Furring to Receive
   Interior and Exterior Portland Cement-based Plaster

2109.3.4.8, 2510.3,
Table 2511.1.1, 2512.1.1
C1088 - 13 Specification for Thin Veneer Brick Units Made from Clay or Shale Table 721.1(2)
C1157/C1157M - 11 Standard Performance Specification for Hydraulic Cement 1903.1, Table 2507.2
C1167 - 11 Specification for Clay Roof Tiles 1507.3.4
C1177/C1177M - 08 Specification for Glass Mat Gypsum Substrate for Use as Sheathing Table 1508.2, Table 2506.2
C1178/C1178M - 11 Specification for Coated Mat Water-resistant Gypsum Backing Panel Table 2506.2, Table 2509.2
C1186 - 08(201 2) Specification for Flat Fiber Cement Sheets 1404.10, 1405.16.1, 1405.16.2
C1261 - 10 Specification for Firebox Brick for Residential Fireplaces 2111.6, 2111.9
C1278/C1278M - 07a(2011) Specification for Fiber-reinforced Gypsum Panels Table 1508.2, Table 2506.2
C1280 - 13 Specification for Application of Exterior Gypsum Panel Products for Use as    Sheathing Table 2508.1, 2508.2
C1283 - 11 Practice for Installing Clay Flue Lining 2113.9.1, 2113.12
C1288 - 99(2010) Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate    Sheets Table 2509.2
C1289 - 13E1 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation    Board
Table 1508.2
2603.0, Table 2603.12.1,
Table 2603.12.2
C1313/C1313M - 12 Standard Specification for Sheet Radiant Barriers for Building Construction    Applications
1509.4
C1325 - 08b Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Backer Units
Table 2509.2
C1328/C1328M - 12 Specification for Plastic (Stucco Cement) Table 2507.2
C1364 - 10B Standard Specification for Architectural Cast Stone 2103.1
C138 - 07 Specification for Precast Autoclaved Aerated Concrete (AAC) Wall Construction    Units 202
C1396M/C1396M - 13 Specification for Gypsum Board Figure 722.5.1(2), Figure 722.5.1(3)
C1492 - 03(2009) Standard Specification for Concrete Roof Tile 1507.3.5
C1600/C1600M - 11 Standard Specification for Rapid Hardening Hydraulic Cement Table 2507.2
C1629/C1629M - 06(2011) Standard Classification for Abuse-resistant Nondecorated
   Interior Gypsum Panel Products and Fiber-reinforced Cement Panels

403.2.3.1, 403.2.3.2, 403.2.3.4
C1658/C1658M - 12 Standard Specification for Glass Mat Gypsum Panels Table 2506.2
D25 - 12 Specification for Round Timber Piles 1810.3.2.4, 2303.1.12
D41 - 05 Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D43 - 00 (2006) Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing
Table 1507.10.2
D56 - 05(2010) Test Method for Flash Point By Tag Closed Tester 202
D86 - 2012 Test Method for Distillation of Petroleum Products at Atmospheric Pressure 202
D93 - 2012 Test Method for Flash Point By Pensky-Martens Closed Cup Tester 202
D225 - 07 Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules 1507.2.5
D226/D226M - 09 Specification for Asphalt-saturated Organic Felt
   Used in Roofing and Waterproofing

1404.2, 1505.2, 1507.2.3, 1507.2.8.1, 1507.3.3, 1507.4.5
1507.5.3, 1507.6.3, 1507.6.3.1, 1507.7.3, Table 1507.8,
1507.8.3, 1507.9.3, 1507.9.5, Table 1507.10.2, 1507.17.3, 1507.17.4.1
D227/D227M -
03(2011)E1
Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing Table 1507.10.2
D312 - 00 (2006) Specification for Asphalt Used in Roofing Table 1507.10.2
D422 - 63 (2007) Test Method for Particle-size Analysis of Soils 1803.5.3
D448 - 08 Standard Classification for Sizes of Aggregate for Road and Bridge Construction 1507.12.3, 1507.13.3
D450 - 07 Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D635 - 10 Test Method for Rate of Burning and/or Extent and
   Time of Burning of Plastics in a Horizontal Position
2606.4
D1143/D1143M - 07el Test Method for Piles Under Static Axial Compressive Load 1810.3.3.1.2
D1227 - 95 (2007) Specification for Emulsified Asphalt Used as a Protective Coating for Roofing Table 1507.10.2, 1507.15.2
D1557 - 12 Test Method for Laboratory Compaction Characteristics
   of Soil Using Modified Effort [56,000 ft-1b/ft3 (2,700 KN m/m3)]

1705.6, 1804.5
D1863/D1863M - 05(2011)E1 Specification for Mineral Aggregate Used on Built-up Roofs Table 1507.10.2
D1929 - 12 Test Method for Determining Ignition Temperature of Plastics 402.6.4.4, 406.7.2, 1407.11.2.1,
1407.11.3.3, 1407.11.4.2, 2606.4
D1970/D1970M - 2013 Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used    as Steep Roof Underlayment for Ice Dam Protection

1507.2.4, 1502.2.8.1, 1507.2.9.2, 1507.3.3.3
1507.3.9, 1507.4.5, 1507.5.3.1, 1507.5.7, 1507.6.3.1,
1507.7.3.1, 1507.8.3.1, 1507.8.8, 1507.9.3.1, 1507.9.9, 1507.17.4.1
D2178 - 04 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D2487 - 2011 Practice for Classification of Soils for Engineering
   Purposes (Unified Soil Classification System)

Table 1610.1, 1803.5.1
D2626/D2626M -
04(2012)E1
Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in    Roofing
1507.3.3
Table 1507.10.2
D2822/D2822M -
05(2011)E1
Specification for Asphalt Roof Cement, Asbestos Containing Table 1507.10.2
D2823/D2823M -
05(2011)E1
Specification for Asphalt Roof Coatings, Asbestos Containing Table 1507.10.2
D2824 - 06(2012)E1 Standard Specification for Aluminum-Pigmented Asphalt Roof Coating,
   Nonfibered, Asbestos Fibered and Fibered without Asbestos

Table 1507.10.2
D2843 - 10 Test for Density of Smoke from the Burning or Decomposition of Plastics 2606.4
D2859 - 06 (2011) Standard Test Method for Ignition Characteristics of Finished
   Textile Floor Covering Materials

804.4.1
D2898 - 10 Test Methods for Accelerated Weathering of Fire-retardant-treated
   Wood for Fire Testing

1505.1, 2303.2.4, 2303.2.6
D3019 - 08 Specification for Lap Cement Used with Asphalt Roll Roofing,
   Nonfibered, Asbestos Fibered and Nonasbestos Fibered

Table 1507.10.2
D3161/D3161M - 13 Test Method for a Wind Resistance of Asphalt Shingles
   (Fan Induced Method)

1504.1.1, Table 1504.1.1, 1507.17.8
D3200 - 74 (2012) Standard Specification and Test Method for Establishing Recommended
   Design Stresses for Round Timber Construction Poles

2303.1.12
D3201 - 2013 Test Method for Hygroscopic Properties of Fire-retardant-treated
   Wood and Wood-based Products

2303.2.7
D3278 - 1996 (2011) Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 202
D3462/D3462M - 10A Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral    Granules
1507.2.5
D3468 - 99(2006)e01 Specification for Liquid-applied Neoprene and
   Chlorosulfonated Polyethylene Used in Roofing and Waterproofing

1507.15.2
D3679 - 11 Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding 1404.9, 1405.14
D3689 - 2013E1 Test Methods for Deep Foundations Under Static Axial Tensile Load 1810.3.3.1.5
D3737 - 2012 Practice for Establishing Allowable Properties for Structural Glued Laminated Timber    (Glulam)
2303.1.3
D3746 - 85 (2008) Test Method for Impact Resistance of Bituminous Roofing Systems 1504.7
D3747 - 79 (2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof lnsulation Table 1507.10.2
D3909/
D3909M - 97b (2012)e1
Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules
1507.2.9.2, 1507.6.5,
D3957 - 09 Standard Practices for Establishing Stress Grades for Structural Members Used in    Log Buildings
2303.1.11
D4022/D4022M -
2007 (2012)E1
Specification for Coal Tar Roof Cement, Asbestos Containing
Table 1507.10.2
D4272 - 09 Test Method for Total Energy Impact of Plastic Films by Dart Drop 1504.7
D4318 - 10 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils 1803.5.3
D4434/D4434M - 12 Specification for Poly (Vinyl Chloride) Sheet Roofing 1507.13.2
D4479/D4479M -
07(2012)E1
Specification for Asphalt Roof Coatings-Asbestos-free
1808.6.2
D4586/D4586M -
07(2012)E1
Specification for Asphalt Roof Cement-Asbestos-free
Table 1507.10.2
D4601/D4601M -
04(2012)E1
Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing
Table 1507.10.2
D4637/D4637M - 13 Specification for EPDM Sheet Used in Single-ply Roof Membrane 1507.12.2
D4829 - 11 Test Method for Expansion Index of Soils 1803.5.3
D4869/D4869M -
05(2011)e01
Specification for Asphalt-saturated (Organic Felt)
   Underlayment Used in Steep Slope Roofing


1507.2.3, 1507.2.8.1, 1507.4.5, 1507.5.3,
1507.5.3.1, 1507.6.3, 1507.7.3, 1507.7.3.1,
1507.8.3, 1507.8.3.1, 1507.9.3, 1507.9.3.1, 1507.17.3, 1507.17.4.1
D4897/D4897M - 01(2009) Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing Table 1507.10.2
D4945 - 12 Test Method for High-strain Dynamic Testing of Piles 1810.3.3.1.2
D4990 - 97a(2005)e01 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D5019 - 07a Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing    Membrane
1507.12.2
D5055 - 13 Specification for Establishing and Monitoring Structural
   Capacities of Prefabricated Wood I-joists

2303.1.2
D5456 - 12 Specification for Evaluation of Structural Composite Lumber Products 2303.1.10
D5516 - 09 Test Method of Evaluating the Flexural Properties of Fire-retardant-treated
   Softwood Plywood Exposed to the Elevated Temperatures

2303.2.5.1
D5643/D5643M -
06(2012)E1
Specification for Coal Tar Roof Cement, Asbestos-free
Table 1507.10.2
D5664 - 10 Test Methods for Evaluating the Effects of Fire-retardant Treatment and
   Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber

2303.2.5.2
D5665 - 99a (2006) Specification for Thermoplastic Fabrics Used in Cold-applied
   Roofing and Waterproofing

Table 1507.10.2
D5726 - 98 (2005) Specification for Thermoplastic Fabrics Used in Hot-applied
   Roofing and Waterproofing

Table 1507.10.2
D6083 - 05e01 Specification for Liquid Applied Acrylic Coating Used in Roofing Table 1507.10.2, Table 1507.14.3,
1507.15.2
D6162 - 2000A (2008) Specification for Styrene-butadiene -styrene (SBS) Modified Bituminous
   Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements

1507.11.2
D6163 - 00 (2008) Specification for Styrene-butadiene-styrene (SBS) Modified
   Bituminous Sheet Materials Using Glass Fiber Reinforcements

1507.11.2
D6164/D6164M - 11 Specification for Styrene-butadiene -styrene (SBS) Modified
   Bituminous Sheet Metal Materials Using Polyester Reinforcements

1507.11.2
D6222/D6222M - 11 Specification for Atactic Polypropylene (APP) Modified
   Bituminous Sheet Materials Using Polyester Reinforcements

1507.11.2
D6223/D6223M -
02(2011)E1
Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet
   Materials Using a Combination of Polyester and Glass Fiber Reinforcements

1507.11.2
D6298 - 05e1 Specification for Fiberglass Reinforced Styrene-butadiene-styrene
   (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface

1507.11.2
D6305 - 08 Practice for Calculating Bending Strength Design Adjustment
   Factors for Fire-retardant-treated Plywood Roof Sheathing

2303.2.5.1
D6380 - 03 (2009) Standard Specification for Asphalt Roll Roofing (Organic) Felt 1507.2.9.2, 1507.3.3, 1507.6.5
D6509/D6509M - 09 Standard Specification for Atactic Polypropylene (APP)
   Modified Bituminous base Sheet Materials Using Glass Fiber Reinforcements

1507.11.2
D6694 - 08 Standard Specification for Liquid-applied Silicone Coating
   Used in Spray    Polyurethane Foam Roofing Systems

Table 1507.14.3, 1507.15.2
D6754/D6745M - 10 Standard Specification for Ketone Ethylene Ester Based Sheet Roofing 1507.13.2
D6757 - 2013 Standard Specification for Underlayment for Use with Steep Slope Roofing 1507.2.3, 1507.17.3, 1507.17.4.1
D6841 - 08 Standard Practice for Calculating Design Value Treatment
   Adjustment Factors for Fire-retardant-treated Lumber

2303.2.5.2
D6878/D6878M - 11a Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing 1507.13.2
D6947 - 07 Standard Specification for Liquid Applied Moisture Cured
   Polyurethane Coating Used in Spray Polyurethane Foam Roofing System

Table 1507.14.3, 1507.15.2
D7032 - 10a Standard Specification for Establishing Performance Ratings for Wood,
   Plastic Composite Deck Boards and Guardrail Systems (Guards or Rails)

2612.2.1, 2612.4, 2612.5.1
D7147 - 05 Specification for Testing and Establishing Allowable Loads of Joist Hangers 2303.5, 2304.10.3
D7158/D7158M - 11 Standard Test Method for Wind Resistance of Sealed
   Asphalt Shingles (Uplift Force/Uplift Resistance Method)
1504.1.1, Table 1504.1.1
D7254 - 07 Standard Specification for polypropylene (PP) siding 1404.12
D7655 - 12 Standard Classification for Size of Aggregate Used as Ballast for Roof Membrane    Systems
1507.12.3, 1507.13.3
D7672 - 2012 Standard Specification for Evaluating Structural Capacities of Rim Board Products    and Assemblies
2303.1.13
E84 - 2013A Test Methods for Surface Burning Characteristics of Building Materials 202, 402.6.4.4, 406.7.2, 703.5.2,
720.1, 720.4, 803.1.1, 803.1.4, 803.10, 803.11,
806.7, 1404.12.1, 1407.9, 1407.10.1, 1409.9, 1409.10.1,
1510.6.2, 1510.6.3, 2303.2, 2603.3, 2603.4.1.13, 2606.3.5.4,
2603.7.1, 2603.7.2, 2603.7.3, 2604.2.4, 2606.4, 2612.3, 2614.3, 3105.4
E90 - 09 Test Method for Laboratory Measurement of Airborne Sound
   Transmission Loss of Building Partitions and Elements

1207.2, 1207.2.1
E96/E96M - 2013 Test Method for Water Vapor Transmission of Materials 202
E108 - 2011 Test Methods for Fire Tests of Roof Coverings 1505.1, 2603.6, 2610.2, 2610.3
E119 - 2012A Standard Test Methods for Fire Tests of Building Construction and Materials 703.2, 703.2.1, 703.2.3,
703.3, 703.4, 703.6, 704.12,
705.7, 705.8.5, 711.3.2, 714.3.1, 714.4.1, 715.1,
716.2, Table 716.3, 716.5.6, 716.5.8.1.1,
Table 716.6, 716.6.7.1, 717.5.2, 717.5.3, 717.6.1,
716.6.2.1, Table 721.1(1), 1409.10.2, 2103.1, 2603.5.1
E136 - 2012 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 703.5.1
E283 - 04 Standard Test Method for Determining Rate of Air Leakage Through Exterior    Windows Curtain Walls, and Doors Under Specified Pressure Difference Across    the Specimen

202
E330 - 02 Test Method for Structural Performance of Exterior Windows, Curtain Walls and
   Doors by Uniform Static Air Pressure Difference

1409.10.2, 1709.5.2
E331 - 00 (2009) Test Method for Water Penetration of Exterior Windows, Skylights,
   Doors and Curtain Walls by Uniform Static Air Pressure Difference
1403.2
E492 - 09 Test Method for Laboratory Measurement of Impact Sound Transmission Through
   Floor-ceiling Assemblies Using the Tapping Machine
1207.3
E605 - 93 (2011) Test Method for Thickness and Density of Sprayed
   Fire-resistive Material (SFRM) Applied to Structural Members

1705.14.4.1, 1705.14.4.2,
1 705.14.4.5, 1705.14.5
E681 - 2009 Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases 202
E736 - 00 (2011) Test Method for Cohesion/Adhesion of Sprayed Fire-resistive
   Materials Applied to Structural Members

704.13.2, 1705.14.6
E814 - 2013 Test Method of Fire Tests of Through-penetration Firestops 202, 714.3.1.2, 714.3.2, 7143.4.1.1.2
E970 - 2010 Test Method for Critical Radiant Flux of Exposed Attic
   Floor Insulation Using a Radiant Heat Energy Source

720.3.1
E1300 - 12AE1 Practice for Determining Load Resistance of Glass in Buildings 2404.1, 2404.2, 2404.3.1,
2404.3.2, 2404.3.3, 2404.3.4, 2404.3.5
E1354 - 2013 Standard Test Method for Heat and Visible Smoke Release Rates for
   Materials and Products Using an Oxygen Consumption Calorimeter

424.2
E1592 - 05(2012) Test Method for Structural Performance of Sheet Metal Roof and Siding Systems
   by Uniform Static Air Pressure Difference

1504.3.2
E1602 - 02(2010)E1 Guide for Construction of Solid Fuel-burning Masonry Heaters 2112.2
E1886 - 05 Test Method for Performance of Exterior Windows, Curtain Walls, Doors and
   Storm Shutters Impacted by Missiles and Exposed to Cyclic Pressure Differentials

1609.1.2
E1966 - 07A(2011) Test Method for Fire-resistant Joint Systems . 202, 715.3
E1996 - 2012A Specification for Performance of Exterior Windows, Curtain Walls,
   Doors and Impact Protective Systems Impacted by Windborne Debris in    Hurricanes

1609.1.2, 1609.1.2.2
E2072 - 10 Standard Specification for Photolurninescent (Phosphorescent) Safety Markings 1025.3
E2174 - 10AE1 Standard Practice for On-Site Inspection of Inspection Stops 1705.17.1
E2178 - 13 Standard Test Method for Air Permeance of Building Materials 202
E2273 - 03(2011) Standard Test Method for Determining the Drainage Efficiency of
   Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies

1408.4.1
E2307 - 2010 Standard Test Method for Determining Fire Resistance of a Perimeter Joint System    Between an Exterior Wall Assembly and Floor Assembly Using the Intermediate-    scale, Multistory Test Apparatus

715.4
E2393 - 10A Standard Practice for On-Site Inspection of Installed
   Fire Resistive Joint Systems and Perimeter Fire Barrier

1705.17.2
E2397 - 11 Standard Practice for Determination of Dead Loads and Live Loads Associated
   with Green Roof Systems

1607.12.3.1
E2404 - 2013E1 Standard Practice for Specimen Preparation and Mounting of Textile, Paper or
   Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics

803.1.4
E2556 - 10 Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers
   Intended for Mechanical Attachment

1404.2, 2510.6
E2568 - 09e1 Standard Specification for PB Exterior Insulation and Finish Systems 1408.2
E2570 - 07 Standard Test Method for Evaluating Water-resistive Barrier (WRB) Coatings Used
   Under Exterior Insulation and Finish Systems (EIFS) for EIFS with Drainage

1408.4.1.1, 1705.16.1
E2573 - 12 Standard Practice for Specimen Preparation and Mounting of Site-fabricated
   Stretch Systems to Assess Surface Burning Characteristics

803.13
E2599 - 11 Standard Practice for Specimen Preparation and Mounting of Reflective Insulation
   Materials and Vinyl Stretch Ceiling Materials for Building Applications to
   Assess Surface Burning Characteristics


2614.3
E2634 - 11 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems 1903.4
E2751 - 11 Standard Practice for Design and Performance of Supported Glass Walkways 2409.1
F547 - (2012) Terminology of Nails for Use with Wood and Wood-based Materials Table 2506.2
F1667 - 11AE1 Specification for Driven Fasteners: Nails, Spikes and Staples Table 721.1(2), Table 721.1(3),
1507.2.6, 1507.17.5, 2303.6, Table 2506.2
F2006 - 00 (2005) 10 Standard/Safety Specification for Window Fall Prevention Devices for
   Nonemergency Escape (Egress) and Rescue (Ingress) Windows

1015.8
F2090 - 10 Specification for Window Fall Prevention Devices with Emergency
   Escape (Egress) Release Mechanisms

1015.8, 1015.8.1
F2200 - 2013 Standard Specification for Automated Vehicular Gate Construction 3110.3
G152 - 06 Practice for Operating Open Flame Carbon Arc Light Apparatus for
   Exposure of Nonmetallic Materials

1504.6
G154 - 06 Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic    Materials
1504.6
G155 - 05a Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic    Materials
1504.6
     

AWC
American Wood Council
222 Catoctin SE, Suite 201
Leesburg, VA 20175
Standard
reference
number
Title Referenced
in code
section number
AWC WCD No. 4 - 2003 Wood Construction Data-Plank and Beam Framing for Residential Buildings 2306.1.2
AWC WFCM - 2015 Wood Frame Construction Manual for One- and Two-Family Dwellings 1609.1.1, 1609.1.1.1,
2301.2, 2308.2.4, 2309.1
ANSI/AWC NDS - 2015 National Design Specification (NDS) for
   Wood Construction with 2015 NDS Supplement

202, 722.1, Table 1604.3, 1809.12, 1810.3.2.4,
Table 1810.3.2.6, 1905.1.8, 2304.13, 2306.1, Table 2306.2(1),
Table 2306.2(2), Table 2306.3(1), Table 2306.3(2), 2307.1
AWC STJR - 2015 Span Tables for Joists and Rafters 2306.1.1, 2308.4.2.1, 2308.7.1, 2308.7.2
ANSI/AWC PWF - 2015 Permanent Wood Foundation Design Specification 1805.2, 1807.1.4, 2304.10.5.2
AWC SDPWS - 2015 Special Design Provisions for Wind and Seismic 202, 2305.1, 2305.2, 2305.3, 2306.1, 2306.2,
2306.3, Table 2306.3(1), Table 2306.3(3), 2307.1
     

AWCI
Association of the Wall and Ceiling Industry
513 West Broad Street, Suite 210
Falls Church, VA 22046
Standard
reference
number
Title Referenced
in code
section number
12 - B - 04 Technical Manual 12-B Standard Practice for the Testing and Inspection of
   Field Applied Thin Film lntumescent Fire-resistive
   Materials; an Annotated Guide, Second Edition


1705.15
     

AWPA
American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236 - 1784
Standard
reference
number
Title Referenced
in code
section number
C1 - 03 All Timber Products-Preservative Treatment by Pressure Processes 1505.6
M4 - 11 Standard for the Care of Preservative-treated Wood Products 1810.3.2.4.1, 2303.1.9
U1 - 14 USE CATEGORY SYSTEM: User Specification for Treated Wood
   Except Section 6, Commodity Specification H

1403.6, Table 1507.9.6, 1807.1.4, 1807.3.1,
1809.12, 1810.3.2.4.1, 2303.1.9, 2304.12.1,
2304.12.2, 2304.12.3, 2304.2.4, 2304.12.5
     

AWS
American Welding Society
8669 NW 36 Street, #130
Doral, FL 33166
Standard
reference
number
Title Referenced
in code
section number
D1.4/D1.4M - 2011 Structural Welding Code-Reinforcing Steel Including Metal Inserts and
   Connections In Reinforced Concrete Construction

1704.5, 1705.3.1, Table 1705.3, 2107.4
     

BHMA
Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York, NY 10017-6603
Standard
reference
number
Title Referenced
in code
section number
A 156.10 - 2011 Power Operated Pedestrian Doors 1010.1.4.2
A 156.19 - 2013 Standard for Power Assist and Low Energy Operated Doors 1010.1.4.2
A 156.27 - 11 Power and Manual Operated Revolving Pedestrian Doors 1010.1.4.1
     

CEN
European Committee for Standardization (CEN)
Central Secretariat
Rue de Stassart 36
B - 10 50 Brussels
Standard
reference
number
Title Referenced
in code
section number
EN 1081 - 98 Resilient Floor Coverings-Determination of the Electrical Resistance 406.7.1
BS EN 15250 - 2007 Slow Heat Release Appliances Fired By Solid Fuel Requirements and Test Methods 2112.2, 2112.5
     

CGSB
Canadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
Standard
reference
number
Title Referenced
in code
section number
37 - GP - 52M (1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric 1504.7, 1507.12.2
37 - GP - 56M (1980) Membrane, Modified, Bituminous, Prefabricated and
   Reinforced for Roofing-with December 1985 Amendment

1507.11.2
CAN/CGSB 37.54 - 95 Polyvinyl Chloride Roofing and Waterproofing Membrane 1507.13.2
     

CPA
Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
Standard
reference
number
Title Referenced
in code
section number
ANSI A135.4 - 2012 Basic Hardboard 1404.3.1, 2303.1.7
ANSI A135.5 - 2012 Prefinished Hardboard Paneling 2303.1.7, 2304.7
ANSI A135.6 - 2012 Engineered Wood Siding 1404.3.2, 2303.1.7
A208.1 - 09 Particleboard 2303.18, 2303.1.8.1
     

CPSC
Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
Standard
reference
number
Title Referenced
in code
section number
16 CFR Part 1201 (2002) Safety Standard for Architectural Glazing Material 2406.2, Table 2406.2(1),
2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1,
2408.3, 2409.2, 2409.3.1, 2409.4.1
16 CFR Part 1209 (2002) Interim Safety Standard for Cellulose Insulation 720.6
16 CFR Part 1404 (2002) Cellulose Insulation 720.6
16 CFR Part 1500 (2009) Hazardous Substances and Articles; Administration and Enforcement Regulations 202
16 CFR Part 1500.44(2009) Method for Determining Extremely Flammable and Flammable Solids 202
16 CFR Part 1507 (2002) Fireworks Devices 202
16 CFR Part 1630 (2007) Standard for the Surface Flammability of Carpets and Rugs 804.4.1
     

CSA
Canadian Standards Association
8501 East Pleasant Valley
Cleveland, OH 44131 - 5516
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440 - 11
Specifications for Windows, Doors and Unit Skylights
1709.5.1, 2405.5
     

CSSB
Cedar Shake and Shingle Bureau
P. 0. Box 1178
Sumas, WA 98295- 1178
Standard
reference
number
Title Referenced
in code
section number
CSSB - 97 Grading and Packing Rules for Western Red Cedar Shakes and
Western Red Shingles of the Cedar Shake and Shingle Bureau

Table 1507.8.5, Table 1507.9.6
     

DASMA
Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115 - 2851
Standard
reference
number
Title Referenced
in code
section number
ANSI/DASMA 107 - 1997
(R2012)

Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation

2603.4.1.9
108 - 12 Standard Method for Testing Sectional Garage Doors and Rolling Doors:
   Determination of Structural Performance Under Uniform Static Air Pressure    Difference


1709.5.2
115 - 12 Standard Method for Testing Sectional Garage Doors and Rolling Doors:
   Determination of Structural Performance Under Missile Impact and Cyclic Wind    Pressure


1609.1.2.3
     

DOC
U.S. Department of Commerce
National Institute of Standards and Technology
1401 Constitution Avenue NW
Washington, DC 20230
Standard
reference
number
Title Referenced
in code
section number
PS - 1 - 09 Structural Plywood 2303.1.5, 2304.7, Table 2304.7(4),
Table 2304.7(5), Table 2306.2(1), Table 2306.2(2)
PS - 2 - 10 Performance Standard for Wood-based Structural-use Panels 2303.1.5, 2304.7, Table 2304.7(5),
Table 2306.2(1), Table 2306.2(2)
PS 20 - 05 American Softwood Lumber Standard 202, 1810.3.2.4, 2303.1.1
     

DOL
U.S. Department of Labor
Frances Perkins Building
200 Constitution A venue NW
Washington, DC 20210
Standard
reference
number
Title Referenced
in code
section number
29CFR
Part 1910.1000 (2009)

Air Contaminants

202
     

DOTn
U.S. Department of Transportation
c/o Superintendent of Documents
East Building, 2nd floor
Washington, DC 20590
Standard
reference
number
Title Referenced
in code
section number
49 CFR Parts 100 - 185
2005

Hazardous Materials Regulations

202
49 CFR Parts 173.137
(2009)
Shippers-General Requirements for Shipments and Packaging -
   Class 8-Assignment of Packing Group

202
49 CFR - 1998 Specification of Transportation of Explosive and Other
   Dangerous Articles, UN 0335, UN 0336 Shipping Containers

202
     

FEMA
Federal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington, DC 20472
Standard
reference
number
Title Referenced
in code
section number
FEMA - TB - 11 - 01 Crawlspace Construction for Buildings Located in Special Flood Hazard Areas 1805.1.2.1
     

FM
Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnston, RI 02919
Standard
reference
number
Title Referenced
in code
section number
4430 (2012) Approval Standard for Heat and Smoke Vents 910.3.1
4470 (2012) Approval Standard for Single-Ply Polymer-Modified Bitumen Sheet, Built-Up Roof    (BUR) And Liquid Applied Roof Assemblies for use in Class 1 and
   Noncombustible Roof Deck Construction


1504.7
4474 (2011) American National Standard for Evaluating the Simulated Wind Uplift Resistance of
   Roof Assemblies Using Static Positive and/or Negative Differential Pressures

1504.3.1, 1504.3.2
4880 - 2010 Approval Standard for Class I Fire Rating of Insulated Wall or Wall and Roof/Ceiling    Panels, Interior Finish Materials or Coatings and Exterior Wall Systems
2603.4, 2603.9
     

GA
Gypsum Association
6525 Belcrest Road, Suite 480
Hyattsville, MD 20782
Standard
reference
number
Title Referenced
in code
section number
GA 216 - 13 Application and Finishing of Gypsum Panel Products Table 2508.1, 2509.2
GA 600 - 12 Fire-Resistance Design Manual, 20th Edition Table 721.1(1), Table 721.1(2), Table 721.1(3)
     

HPVA
Hardwood Plywood Veneer Association
1825 Michael Faraday Drive
Res ton, VA 20190
Standard
reference
number
Title Referenced
in code
section number
HP - 1 - 2013 Standard for Hardwood and Decorative Plywood 2303.3, 2304.7
     

ICC
International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
ICC A117.1 - 09 Accessible and Usable Buildings and Facilities 202, 907.5.2.3.3, 1009.8.2, 1009.9,
1009.11, 1010.1.9.7, 1012.1, 1012.6.5,
1012.10, 1013.4, 1023.9, 1101.2, 1111.2,
1111.3, 1111.4, 1111.4.2
• ICC 300 - 12 ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands 1029.1.1 Table 1607.1
ICC 400 - 12 Standard on Design and Construction of Log Structures 2301.2
ICC 500 - 14 ICC/NSSA Standard on the Design and Construction of Storm Shelters 202, 423.1, 423.3, 423.4
ICC 600 - 14 Standard for Residential Construction in High-wind Regions 1609.1.1, 1609.1.1.1, 2308.2.1
IFC - 15 International Fire Code® 101.4.5, 102.6, 201.3, 202,307.1, Table 307.1(1), Table 307.1(2),
307.1.1, 307.1.2, 403.4.5, 404.2, 406.7, 406.8, 407.2.6, 407.4, 410.3.6,
411.1, 412.1, 412.6.1, 413.1, 414.1.1, 414.1.2, 414.1.2.1, 414.2, 414.2.5,
Table 414.2.5(1), Table 414.2.5(2), 414.3, 414.5, 414.5.1, Table 414.5.1,
414.5.2, 414.5.3, 414.5.4, 414.6, 415.1, 415.6, 415.6.1, 415.6.1.1, 415.6.1.4,
Table 415.6.2, 415.7.3, 415.8.2, 415.9, 415.9.1, 415.9.1.3, 415.9.1.4, 415.9.1.6,
415.9.1.7, 415.9.1.8, 415.9.2, 415.9.3, 415.10, 415.11, 415.11.1.7, 415.11.4,
415.11.7.2, 415.11.9.3, 415.11.10.1, 416.1, 416.4, 421.1, 422.3.1, 426.1.4, Table 504.3,
Table 504.4, Table 506.2, 507.4, 507.8.1.1.1, 507.8.1.1.2, 507.8.1.1.3, 705.8.1, 707.1, 901.2,
901.3, 901.5, 901.6.2, 901.6.3, 903.1.1, 903.2.7.1, 903.2.11.6, 903.2.12, 903.5, 904.2.1,
904.12.3, 905.1, 905.3.6, 906.1, 907.1.8, 907.2.5, 907.2.13.2, 907.2.15, 907.2.16,
907.6.5, 907.8, 909.20, 910.2.2, 1001.3, 1001.4, 1010.1.9.6, 1203.5.2, 1203.6,
1507.16, 1512.1, Table 1604.5, 2603.4.1.12, 2702.1, 2702.1.2, 2702.2.3, 2702.2.8,
2702.2.9, 2702.2.11, 2702.2.12, 2702.2.13, 2702.4, 3003.3, 3008.1.2, 3102.1, 3103.1
,3111.1, 3111.1.1, 3302.3, 3303.7, 3309.2
IFGC - 15 International Fuel Gas Code® 101.4.1, 201.3, Table 307.1(1), 415.9.2, 2113.11.1.2,
2113.15, 2801.1
IPMC - 15 International Property Maintenance Code® 101.4.4, 102.6, 103.3
IRC - 15 International Residential Code® 101.2, 305.2.3, 308.3.4, 308.4.2, 308.6.4,
310.1, 310.5.1, 310.5.2, 2308.1
IWUIC - 15 International Wildland-Urban Interface Code® Table 1505.1
SBCCI SSTD 11 - 97 Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles 1504.2.1.1, 1504.2.1.2
     

ISO
International Organization for Standardization
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case Postale 56
CH - 1211 Geneva 20, Switzerland
Standard
reference
number
Title Referenced
in code
section number
ISO 8115 - 86 Cotton Bales-Dimensions and Density Table 307.1(1), Table 415.11.1.1.1
ISO 8336 - 09 Fiber-Cement Flat Sheets - Product Specification and Test Methods 1404.10, 1405.16.1,
1404.10, 1405.16.1,
     

MHI
Material Handling Institute
8720 Red Oak Blvd. Suite 201
Charlotte, NC 28217
Standard
reference
number
Title Referenced
in code
section number
ANSI MH29.1 - 08 Safety Requirements for Industrial Scissors Lifts 3001.2
     

MI
Michigan Department of Licensing and Regulatory Affairs
Bureau of Construction Codes
2501 Woodlake Circle
Okemos, Michigan 48864
Standard
reference
number
Title Referenced
in code
section number
  (a) Michigan Electrical Code R 408.30801 to R 408.30880 of the Michigan Administrative Code
  (b) Michigan Mechanical Code R 408.30901 to R 408.30998a of the Michigan Administrative Code
  (c) Michigan Plumbing Code R 408.30701 to R 408.30796 of the Michigan Administrative Code
  (d) Michigan Uniform Energy Code R 408.31061 to R 408.31099 of the Michigan Administrative Code
  (e) Michigan Elevator Code R 408.7001 to R 408.8695 of the Michigan Administrative Code
  (f) Michigan Boiler Code R 408.4001 to R 408.5507 of the Michigan Administrative Code
     

NAAMM
National Association of Architectural Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312
Glen Ellyn, IL 60137
Standard
reference
number
Title Referenced
in code
section number
FP 1001 - 07 Guide Specifications for Design of Metal Flag Poles 1609.1.1
     

NCMA
National Concrete Masonry Association
13750 Sunrise Valley
Herndon, VA 22071 - 4662
Standard
reference
number
Title Referenced
in code
section number
TEK 5 - 84 (1996) Details for Concrete Masonry Fire Walls Table 721.1(2)
     

NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169 - 7471
Standard
reference
number
Title Referenced
in code
section number
10 - 13 Standard for Portable Fire Extinguishers 906.2, 906.3.2, 906.3.4, Table 906.3(1), Table 906.3(2)
11 - 10 Standard for Low Expansion Foam 904.7
12 - 11 Standard on Carbon Dioxide Extinguishing Systems 904.8, 904.11
12A - 09 Standard on Halon 1301 Fire Extinguishing Systems 904.9
13 - 13 Installation of Sprinkler Systems 708.2, 903.3.1.1, 903.3.2, 903.3.8.2, 903.3.8.5
904.11, 905.3.4, 907.6.4, 1019.3
13D - 13 Standard for the Installation of Sprinkler Systems in One- and Two-family
   Dwellings and Manufactured Homes

903.3.1.3
13R - 13 Standard for the Installation of Sprinkler Systems in
   Low Rise Residential Occupancies

903.3.1.2, 903.3.5.2, 903.4
14 - 13 Standard for the Installation of Standpipe and Hose System 905.2, 905.3.4, 905.4.2, 905.6.2, 905.8
16 - 15 Standard for the Installation of Foam-water Sprinkler and Foam-water Spray    Systems 904.7, 904.11
17 - 13 Standard for Dry Chemical Extinguishing Systems 904.6, 904.11
17A - 13 Standard for Wet Chemical Extinguishing Systems 904.5, 904.11
20 - 13 Standard for the Installation of Stationary Pumps for Fire Protection 913.1, 913.2.1, 913.5
30 - 12 Flammab le and Combustible Liquids Code .415.6, 507.8.1.1.1, 507.8.1.1.2
31 - 11 Standard for the Installation of Oil-burning Equipment 2113.15
32 - 11 Standard for Dry Cleaning Plants 415.9.3
40 - 11 Standard for the Storage and Handling of Cellulose Nitrate Film .409.1
58 - 14 Liquefied Petroleum Gas Code 415.9.2
61 - 13 Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food    Product Facilities
426.1
72 - 13 National Fire Alarm and Signaling Code .407.4.4.3, 407.4.4.5, 407.4.4.5.1,
901.6, 903.4.1, 904.3.5, 907.2, 907.2.6, 907.2.11,
907.2.13.2, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.2.2,
907.5.2.2.5, 907.6, 907.6.1, 907.6.2, 907.6.6, 907.7, 907.7.1, 907.7.2,
907.2.9.3, 911.1.5, 2702.2.4, 3005.5, 3007.7
80 - 13 Standard for Fire Doors and Other Opening Protectives 410.3.5, 509.4.2, 716.5, 716.5.7, 716.5.8.1,
716.5.9.2, 716.6, 716.6.4, 1010.1.4.3
82 - 14 Standard on Incinerators and Waste and Linen Handling Systems and Equipment 713.13
85 - 15 Boiler and Combustion System Hazards Code 415.8.1
92 - 15 Standard for Smoke Control Systems 909.7, 909.8
99 - 15 Health Care Facilities Code 407.10, 425.1
101 - 15 Life Safety Code 1029.6.2
105 - 13 Standard for Smoke Door Assemblies and Other Opening Protectives 405.4.2, 710.5.2.2,
716.5.3.1, 909.20.4.1
110 - 13 Standard for Emergency and Standby Power Systems 2702.1.2
111 - 13 Standard on Stored Electrical Energy Emergency and Standby Power Systems 2702.1.2
120 - 15 Standard for Fire Prevention and Control in Coal Mines 426.1
170 - 15 Standard for Fire Safety and Emergency Symbols 1025.2.6.1
211 - 13 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 2112.5
221 - 15 Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls 706.2
252 - 12 Standard Methods of Fire Tests of Door Assemblies 715.4.2, 715.4.3, 715.4.7.3.1, Table 716.3,
716.3.1, 716.4, 716.5.1, 716.5.3, 716.5.8, 716.5.8.1.1
253 - 15 Standard Method of Test for Critical Radiant Flux of Floor Covering Systems
   Using a Radiant Heat Energy Source

406.8.3, 424.2, 804.2, 804.3
257 - 12 Standard for Fire Test for Window and Glass Block Assemblies Table 716.3, 716.4, 716.5.3.2, 716.6,
716.6.1, 716.6.2, 716.6.7.3
259 - 13 Standard Test Method for Potential Heat of Building Materials 2603.4.1.10, 2603.5.3
265 - 11 Standard Methods of Fire Tests for Evaluating Room Fire Growth
   Contribution of Textile Wall Coverings on Full Height Panels and Walls

803.1.3, 803.1.3.1
268 - 12 Standard Test Method for Determining Ignitability of Exterior
   Wall Assemblies Using a Radiant Heat Energy Source
1406.2.1.1, 1406.2.1.1.1, 1406.2.1.1.2,
2603.5.7, D105.1
275 - 13 Standard Method of Fire Tests for the Evaluation of Thermal Barriers 1407.10.2, 2603.4
276 - 11 Standard Method of Fire Tests for Determining the Heat Release Rate of
   Roofing Assemblies With Combustible Above-Deck Roofing Components

1508.1, 2603.3, 2603.4.1.5
285 - 12 Standard Fire Test Method for the Evaluation of Fire Propagation Characteristics of
   Exterior Nonload-bearing Wall Assemblies Containing Combustible Components

718.2.6, 1403.5,
1407.10.4, 1409.10.4,
1510.6.2, 2603.5.5
286 - 15 Standard Methods of Fire Test for Evaluating Contribution of
   Wall and Ceiling Interior Finish to Room Fire Growth

402.6.4.4, 803.1.2, 803.1.2.1, 803.11,
2603.4, 2603.7.2, 2603.9, 2604.2.4, 2614.4
288 - 12 Standard Methods of Fire Tests of Horizontal Fire Door Assemblies
   Installed in Horizontal in Fire-resistance-rated Floor Systems

712.1.13.1
289 - 13 Standard Method of Fire Test for Individual Fuel Packages 402.6.2, 424.2
409 - 11 Standard for Aircraft Hangars 412.4.6, Table 412.4.6, 412.4.6.1, 41
418 - 11 Standard for Heliports 412.8.4
484 - 15 Standard for Combustible Metals 426.1
654 - 13 Standard for the Prevention of Fire & Dust Explosions from the Manufacturing,
   Processing and Handling of Combustible Particulate Solids
426.1
655 - 12 Standard for the Prevention of Sulfur Fires and Explosions 426.1
664 - 12 Standard for the Prevention of Fires and Explosions in Wood Processing and
   Woodworking Facilities

426.1
701 - 10 Standard Method of Fire Tests for Flame-Propagation of Textiles and Films 410.3.6, 424.2, 801.4, 806.1,
806.3, 806.4, 3102.3, 3102.3.1,
3102.6.1.1, 3105.4, D102.2.8, H106.1.1
704 - 12 Standard System for the Identification of the Hazards of
   Materials for Emergency Response

202, 415.5.2
720 - 15 Standard for the Installation of Carbon Monoxide (CO) Detection and
   Warning Equipment

9151.6.1, 915.1.6.2
750 - 14 Standard on Water Mist Fire Protection Systems 904.12.1.1
1124 - 06 Code for the Manufacture, Transportation and Storage of Fireworks and
   Pyrotechnic Articles

415.6.1.1
2001 - 15 Standard on Clean Agent Fire Extinguishing Systems 904.10
     

PCI
Precast Prestressed Concrete Institute
200 West Adams Street, Suite 2100
Chicago, LL 60606-6938
Standard
reference
number
Title Referenced
in code
section number
MNL 124 - 11 Design for Fire Resistance of Precast Prestressed Concrete 722.2.3.1
MNL 128 - 01 Recommended Practice for Glass Fiber Reinforced Concrete Panels 1903.3
     

PTI
Post-Tensioning Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
Title Referenced
in code
section number
PTI DC - 10.5 - 12 Standard Requirements for Design and Analysis of Shallow Concrete
   Foundations on Expansive Soils

1808.6.2
     

RMI
Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte, NC 28217
Standard
reference
number
Title Referenced
in code
section number
ANSI/MH16.1 - 12 Specification for Design, Testing and Utilization of Industrial Steel Storage Racks 2209.1
     

SBCA
Structural Building Components Association
6300 Enterprise Lane
Madison, WI 53719
Standard
reference
number
Title Referenced
in code
section number
ANSI/FS 100 - 12 Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating
   Sheathing Used in Exterior Wall Covering Assemblies

2603.10
     

SDI
Steel Deck Institute
P. 0. Box 426
Glenshaw, PA 15116
Standard
reference
number
Title Referenced
in code
section number
ANSI/NC1.0 - 10 Standard for Noncomposite Steel Floor Deck 2210.1.1.1
ANSI/RD1.0 - 10 Standard for Steel Roof Deck 2210.1.1.2
SDI - C - 2011 Standard for Composite Steel Floor Deck Slabs 2210.1.1.3
SDI - QA/QC - 2011 Standard for Quality Control and Quality Assurance for Installation of Steel Deck 1705.2.2
     

SJI
Steel Joist Institute
11738 London Links Drive
Forest, VA 2
Standard
reference
number
Title Referenced
in code
section number
CJ - 10 Standard Specification for Composite Steel Joists, CJ-series 1604.3.3, 2203.2, 2207.1
JG - 10 Standard Specification for Joist Girders 1604.3.3, 2203.2, 2207.1
K - 10 Standard Specification for Open Web Steel Joists, K-series 1604.3.3, 2203.2, 2207.1
LH/DLH - 10 Standard Specification for Longspan Steel Joists, LH-series
   and Deep Longspan Steel Joists, DLH-series

1604.3.3, 2203.2, 2207.1
     

SPRI
Single-Ply Roofing Institute
411 Waverly Oaks Road, Suite 331B
Waltham, MA 02452
Standard
reference
number
Title Referenced
in code
section number
ANSI/SPRI/
FM4435 - ES - 1 - 11

Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems

1504.5
ANSI/SPRI RP - 4 - 13 Wind Design Guide for Ballasted Single-ply Roofing Systems 1504.4
ANSI/SPRI VF1 - 10 External Fire Design Standard for Vegetative Roofs 1505.10
     

TIA
Telecommunications Industry Association
1320 N. Courthouse Road
Arlington, VA 22201 - 3834
Standard
reference
number
Title Referenced
in code
section number
222 - G - 05 Structural Standards for Antenna Supporting Structures and Antennas,
   including-Addendum 1, 222-G-1, Dated 2007, Addendum 2, 222-G-2 Dated 2009
   Addendum 3, 222-3 dated 2013 and Addendum 4, 222-G-4 dated 2014


1609.1.1,
3108.1, 3108.2
     

TMS
The Masonry Society
105 South Sunset Street, Suite Q
Longmont, CO 80501
Standard
reference
number
Title Referenced
in code
section number
216 - 2013 Standard Method for Determining Fire Resistance of Concrete
   and Masonry Construction Assemblies

Table 721.1(2), 722.1
302 - 2012 Standard Method for Determining the Sound Transmission Class Rating for Masonry    Walls
1207.2.1
402 - 2013 Building Code for Masonry Structures 1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4,
1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9
2101.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4,
2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2109.3, 2110.1
403 - 2013 Direct Design Handbook for Masonry Structures 2101.2
602 - 2013 Specification for Masonry Structures 1405.6.1, 1705.4, 1807.1.6.3,
2103.1, 2103.2.1, 2103.3, 2103.4, 2104.1, 2105.1
     

TPI
Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
TPI 1 - 2014 National Design Standard for Metal-plate-connected Wood Truss Construction 2303.4.6, 2306.1
     

UL
UL LLC
333 Pfingsten Road
Northbrook, IL 60062 - 2096
Standard
reference
number
Title Referenced
in code
section number
9 - 2009 Fire Tests of Window Assemblies 715.5.2, 716.3.2, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.8.1
10A - 2009 Tin Clad Fire Doors 716.5
10B - 2008 Fire Tests of Door Assemblies-with Revisions through April 2009 716.5.2
10C - 2009 Positive Pressure Fire Tests of Door Assemblies 716.5.1, 716.5.3, 1010.1.10.1
14B - 2008 Sliding Hardware for Standard Horizontally mounted Tin Clad Fire Doors -
   with Revisions through May 3, 2013

716.5
14C - 06 Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs -
   with Revisions through May 2013

716.5
55A - 04 Materials for Built-Up Roof Coverings 1507.10.2
103 - 2010 Factory-built Chimneys, for Residential Type and Building Heating Appliances -
   with Revisions through July 2012

718.2.5.1
127 - 2011 Factory-built Fireplaces 718.2.5.1, 2111.11
199E - 04 Outline of Investigation for Fire Testing of Sprinklers and
   Water Spray Nozzles for Protection of Deep Fat Fryers

904.11.4.1
217 - 06 Single and Multiple Station Smoke Alarms-with Revisions through April 2012 907.2.11
263 - 11 Standard for Fire Tests of Building Construction and Materials 703.2, 703.2.1, 703.2.3, 703.3, 703.4,
703.6, 704.12, 705.7, 705.8.5, 707.7, 711.3.2, 714.3.1,
714.4.1.1, 715.1, 716.2, Table 716.3, 716.5.6, 7 16.5.8.1.1,
716.7.1, 717.5.2, 717.5.3, 717.6.2.1, Table 721.1(1),
1407.10.2, 2103.1, 2603.4, 2603.5.1
268 - 09 Smoke Detectors for Fire Alarm Systems .407.8, 907.2.6.2, 907.2.11.7
294 - 1999 Access Control System Units-with Revisions through September 2010 1010.1.9.6, 1010.1.9.8, 1010.1.9.9
300 - 05(R2010) Fire Testing of Fire Extinguishing Systems for Protection of
   Commercial Cooking Equipment-with Revisions through July 16, 2010

904.11
300A - 06 Outline of Investigation for Extinguishing System Units for Residential Range
   Top Cooking Surfaces

.407.2.6, 904.13
305 - 2012 Panic Hardware 1010.1.10.1
325 - 02 Door, Drapery, Gate, Louver and Window Operations and Systems
   with Revisions through June 2013

406.3.6, 3110.4
555 - 2006 Fire Dampers-with Revisions through May 2012 717.3
555C - 2006 Ceiling Dampers- with Revisions through May 2010 717.3
555S - 99 Smoke Dampers- with Revisions through May 2012 717.3, 717.3.1
580 - 2006 Test for Uplift Resistance of Roof Assemblies-with Revisions through July 2009 1504.3.1, 1504.3.2
641 - 2010 Type L Low-temperature Venting Systems- with Revisions through May 2013 2113.11.1.4
710B - 2011 Recirculating Systems 904.11
723 - 2008 Standard for Test for Surface Burning Characteristics of
   Building Materials- with Revisions through September 2010

202, 402.6.4.4,
406.7.2, 703.5.2, 720.1, 720.4, 803.1.1,
803.1.4, 803.10, 803.11, 806.7, 1404.12.1, 1407.9, 1407.10.1,
1409.9, 1409.10.1, 1510.6.2, 1510.6.3, 2303.2, 2603.3,
2603.4.1.13, 2606.3.5.4, 2603.7.1, 2603.7.2, 2603.7.3,
2604.2.4, 2606.4, 26 12.3, 2614.3, 3105.4
790 - 04 Standard Test Methods for Fire Tests of Roof Coverings -
   with Revisions through October 2008

1505.1, 2603.6, 2610.2, 2610.3
793 - 08 Standards for Automatically Operated Roof Vents for Smoke and Heat -
   with Revisions through September 2011

406.8.5.1.1, 910.3.1
864 - 03 Standards for Control Units and Accessories for Fire Alarm Systems -
   with Revisions through August 2012

421.6.2, 909.12
924 - 06 Standard for Safety Emergency Lighting and Power Equipment -
   with Revisions through February 2011

1013.5
1040 - 96 Fire Test of Insulated Wall Construction -
   with Revisions through October 2012

1407.10.3, 1409.10.3, 2603.4, 2603.9
1256 - 02 Fire Test of Roof Deck Construction -
   with Revisions through January 2007

1508.1, 2603.3, 2603.4.1.5
1479 - 03 Fire Tests of Through-penetration Firestops -
   with Revisions through October 2012

202, 714.3.1.2, 714.3.2, 714.4.1.2, 714.4.4
1482 - 2011 Solid-Fuel-type Room Heaters 2112.2, 2112.5
1703 - 02 Flat-Plate Photovoltaic Modules and Panels -
   with Revisions through November 2014

1505.9, 1507.17.1, 1507.17.6, 1509.7.4
1715 - 97 Fire Test of Interior Finish Material -
   with Revisions through January 2013

1407.10.3, 1409.10.2, 1409.10.3, 2603.4, 2603.9, 2614.4
1777 - 2007 Chimney Liners-with Revisions through July 2009 2113.11.1, 2113.19
1784 - 01 Air Leakage Tests of Door Assemblies -
   with Revisions through July 2009

710.5.2.2, 710.5.2.2.1, 716.5.3.1, 716.5.7.1,
716.5.7.3, 3006.3, 3007.6.3, 3008.6.3
1897 - 12 Uplift Tests for Roof Covering Systems 1504.3.1
1975 - 06 Fire Test of Foamed Plastics Used for Decorative Purposes 402.6.2, 402.6.4.5, 424.2
1994 - 04 Luminous Egress Path Marking Systems -
   with Revisions through November 2010

411.7, 1025.2.1, 1025.2.3, 1025.2.4, 1025.4
2017 - 2008 Standards for General-purpose Signaling Devices and Systems -
   with Revisions through May 2011

406.8.5.1.1
2034 - 2008 Standard for Single- and Multiple-Station Carbon Monoxide Alarm -
   with Revisions through February 2009

915.4.2, 915.4.3
2075 - 2013 Standard for Gas and Vapor Detectors and Sensors 421.6.2, 406.8.5.1.1, 915.5.1, 915.5.3
2079 - 04 Tests for Fire Resistance of Building Joint Systems -
   with Revisions through December 2012

202, 715.3, 715.6
2196 - 2001 Tests for Fire Resistive Cables-with Revisions through March 2012 913.2.2, 2702.3
2200 - 2012 Stationary Engine Generator Assemblies-with Revisions through June 2013 2702.1.1
     

ULC
Underwriters Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada M1R3B4
Standard
reference
number
Title Referenced
in code
section number
CAN/ULC S 102.2 - 2010 Standard Method of Test for Surface Burning Characteristics of Flooring,
   Floor Coverings and Miscellaneous Materials and Assemblies-with 2000 Revisions

720.4
     

USC
United States Code
c/o Superintendent of Documents
U.S. Government Printing Office
732 North Capitol Street NW
Washington, DC 20401
Standard
reference
number
Title Referenced
in code
section number
18 USC Part 1, Ch.40 Importation, Manufacture, Distribution and Storage of Explosive Materials 202
     

WCLIB
West Coast Lumber Inspection Bureau
P. 0. Box 23145
Portland, OR 97281
Standard
reference
number
Title Referenced
in code
section number
AITC Technical
Note 7 - 96

Calculation of Fire Resistance of Glued Laminated Timbers

722.6.3.3
AITC 104 - 03 Typical Construction Details 2306.1
AITC 110 - 01 Standard Appearance Grades for Structural Glued Laminated Timber 2306.1
AITC 113 - 10 Standard for Dimensions of Structural Glued Laminated Timber 2306.1
AITC 117 - 10 Standard Specifications for Structural Glued Laminated Timber of Softwood Species 2306.1
AITC 119 - 96 Standard Specifications for Structural Glued Laminated Timber of Hardwood Species 2306.1
AITC 200 - 09 Manufacturing Quality Control Systems Manual for Structural Glued Laminated    Timber 2306.1
     

WDMA
Window and Door Manufacturer s Association
2025 M Street, NW Suite 800
Washington, DC 20036-3309
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMNCSA
101/I.S.2/A440 - 11

Specifications for Windows, Doors and Unit Skylights

1709.5.1, 2405.5
     

WRI
Wire Reinforcement Institute, Inc.
942 Main Street, Suite 300
Hartford, CT 06103
Standard
reference
number
Title Referenced
in code
section number
WRI/CRSI - 81 Design of Slab-on-ground Foundations - with 1996 Update 1808.6.2