Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.7.

AHRI Air Conditioning, Heating and Refrigeration Institute
2111 Wilson Boulevard, Suite 500
Arlington, VA 22201
Standard
reference
number
Title Referenced
in code
section number
1160(I-P)—09 Performance Rating of Heat Pump Pool Heaters Table 316.2


ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A108/A118/A136.1—2009 Specifications for Installation of Ceramic Tile Table 307.4
Z21.56a/CSA 4.7—2013 Gas Fired Pool Heaters Table 316.2


APSP The Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
ANSI/APSP/ICC 4—12 Standard for Aboveground/Onground Residential Swimming Pools 702.2.1
ANSI/APSP/ICC 7—13 American National Standard for Suction Entrapment Avoidance in Swimming Pools,
Wading Pools, Spas, Hot Tubs, and Catch Basins.
310.1
ANSI/APSP/ICC 14—11
ANSI/APSP/
American National Standard for Portable Electric Spa Energy Efficiency 303.2
ICC 15a —2013 American National Standard for Residential Swimming Pool and Spa Energy Efficiency 303.3
ANSI/APSP/ICC 16—11 American National Standard for Suction Fittings for Use in Swimming Pools,
Wading Pools, Spas, and Hot Tubs
202, 311.4.1, 311.4.4,505.2.1


ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
Standard
reference
number
Title Referenced
in code
section number
ASCE 24—13 Flood Resistant Design & Construction 304.3


ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
A112.1.2—2004 Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water-Connected Receptors) 318.2
ASME B16.15—2011 Cast Bronze Threaded Fittings Table 311.4.1


ASTM ASTM International
100 Barr Harbor
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A 182—13 Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges,
Forged Fittings, and Valves and Parts for High-Temperature Service
Table 311.4.1
A 240—13a Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate,
Sheet and Strip for Pressure Vessels and for General Applications
Table 307.4
A 312—13a Standard Specification for Seamless, Welded, and Heavily Cold
Worked Austenitic Stainless Steel Pipes
Table 311.4
A 403—13 Standard Specification for Wrought Austenitic Stainless Steel Piping Fittings Table 311.4.1
B 88—09 Standard Specification for Seamless Copper Water Tube Table 311.4
B 447—12a Specification for Welded Copper Tube Table 311.4
D 1527—99(2005) Specifications for Acrylonitrile Butadiene Styrene (ABS) Plastic Pipe,
Schedules 40 and 80
Table 311.4, Table 311.4.1
D 1593—09 Non-rigid vinyl chloride plastic film and sheeting Table 307.4
D 1785—12 Specification for Poly Vinyl Chloride (PVC) Plastic Pipe, Schedules 40, 80 and 120 Table 311.4
D 2241—09 Standard Specification for Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series)
D 2464—06 Standard Specification for Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings,
Schedule 80
Table 311.4.1
D 2466—06 Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings,
Schedule 40
Table 311.4.1
D 2467—06 Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Table 313.4.1
D 2672—96a(2009) Standard Specification for Joints for IPS PVC Pipe Using Solvent Cement Table 311.4
D 2846/D2846M—09be1 Standard Specification for Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Hotand
Cold-Water Distribution Systems
Table 311.4, Table 311.4.1
F 437—09 Standard Specification for Threaded Chlorinated Poly(Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
Table 311.4.1
F 438—09 Standard Specification for Socket-Type Chlorinated Poly(Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 40
Table 311.4.1
F 439—12 Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
Table 311.4.1
F 1346—91(2010) Standard Performance Specification for Safety Covers and Labeling
Requirements for All Covers for Swimming Pools, Spas and Hot Tubs
305.1, 305.4


CPSC Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 30814-4408
Standard
reference
number
Title Referenced
in code
section number
16 CFR Part 1207—04 Safety Standard for Swimming Pool Slides 406.10


CSA CSA Group
8501 East Pleasant Valley
Cleveland, OH 44131-5516
Standard
reference
number
Title Referenced
in code
section number
B137.2—13 Polyvinylchloride (PVC) Injection-Moulded Gasketed Fittings for Pressure Application Table 311.4,
Table 311.4.1
B137.3—13 Rigid Polyvinylchloride (PVC) Pipe and Fitting and Pressure Applications Table 311.4, Table 311.4.1
B137.6—13 Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing, and Fitting for Hot- and
Cold-Water Distribution Systems
Table 311.4, Table 311.4.1
C22.2 No. 108—01
(R2010)
Liquid Pump 313.8
C22.2 No. 218.1—
M89 (R2011)
Spas, Hot Tubs and Associated Equipment 302.3, 309.1, 310.1, 313.8, Table 316.2,
317.2, 509.1, 1001.4, 1001.7
C22.2 No. 236—11 Cooling Equipment Table 316.2
Z21.56a/CSA 4.7—2013 Gas Fired Pool Heaters Table 316.2


IAPMO IAPMO
4755 E. Philadelphia Street
Ontario, CA 91761-USA
Standard
reference
number
Title Referenced
in code
section number
IAPMO Z124.7—2012 Prefabricated Plastic Spa Shells Table 307.4


ICC International Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
IBC—15 International Building Code® 201.3, 304.2, 306.1, 307.2, 307.4, 307.8, 307.9, 410.1
IECC—15 International Energy Conservation Code® 201.3, 316.4
IFC—15 International Fire Code® 201.3
IFGC—15 International Fuel Gas Code® 201.3, 316.4
IMC—15 International Mechanical Code® 201.3, 316.4
IPC—15 International Plumbing Code® 201.3, 302.2, 302.5, 302.6, 306.8, 306.8.1, 318.2, 410.1
IRC—15 International Residential Code® 102.7.1, 201.3, 302.1, 302.5, 302.6, 304.2, 306.1,
306.3, 306.8, 306.8.1, 307.2, 307.4, 307.8,
307.9, 316.4, 318.2, 321.2.1, 321.4, 703.1, 802.1, 802.2


NEMA National Electrical Manufacturers Association
1300 North 17th Street
Suite 1752
Rosslyn, VA 2209
Standard
reference
number
Title Referenced
in code
section number
NEMA Z535—2006 ANSI/NEMA Color Chart 409.3


NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Standard
reference
number
Title Referenced
in code
section number
NFPA 70—2014 National Electrical Code 302.1, 316.4, 321.2.1, 321.4


NSF NSF International
789 Dixboro Road
Ann Arbor, MI 48105
Standard
reference
number
Title Referenced
in code
section number
NSF 14—2011 Plastics Pumping Systems Components and Related Materials 302.3, 311.4
NSF 50—2012 Equipment for Swimming Pools, Spas, Hot Tubs, and other
Recreational Water Facilities
302.3, 309.2, Table 316.2, 508.1


UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
Title Referenced
in code
section number
372—2007 Automatic Electrical Controls for Household and Similar Use—Part 2: Particular
Requirements for Burner Ignition Systems and Components—
with revisions through July 25, 2012
506.2.1, 506.2.2
873—2007 Temperature-Indicating and Regulating Equipment—
with revisions through July 25, 2012
506.2.1, 506.2.2
1004-1—12 Standard for Rotating Electrical Machines General Requirements—
with revisions through June 23, 2011
313.8
1081—2008 Standard for Swimming Pool Pumps, Filters and Chlorinators—
with revisions through May 2013
313.8
1261—2001 Standard for Electric Water Heaters for Pools and Tubs—
with revisions through July 2012
Table 316.2
1563—2009 Standard for Electric Hot Tubs, Spas and Associated Equipment—
with revisions through July 2012
302.3, 309.1, 310.1, 313.8, Table 316.2,
317.2, 509.1, 1001.4, 1001.7
1995—2011 Heating and Cooling Equipment Table 316.2
2017—2008 General-Purpose Signaling Devices and Systems—with revisions through May 2011 305.4
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING