Table AG101.1 provides a list of plastic piping product standards for various applications.
TABLE AG101.1 PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa,b
(continued)
TABLE AG101.1‒continued PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa,b
(continued)
TABLE AG101.1‒continued PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa,b
TABLE AG101.1 PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa,b
APPLICATION | LOCATION | TYPE OF PLASTIC PIPING | ||||||||
ABS | CPVC | PE | PE-AL- PE | PE-RT | PEX | PEX-AL- PEX | PP | PVC | ||
Central vacuum | System piping | ‒ | ‒ | ‒ | ‒ | ‒ | ‒ | ‒ | ‒ | ASTM F 2158 |
Foundation drainage | System piping | ASTM F 628 | ‒ | ASTM F 405 | ‒ | ‒ | ‒ | ‒ | ‒ | ASTM D 2665 ASTM D 2729 ASTM D 3034 |
Geothermal ground loop | System piping | ‒ | ASTM D 2846 ASTM F 441 ASTM F 442 ASTM F 2855 CSA B137.6 | ASTM D 2239 ASTM D 2737 ASTM D 3035 | ASTM F 1282 | ASTM F 2623 ASTM F 2769 | ASTM F 876 CSA B137.5 | ASTM F 1281 | ASTM F 2389 CSA B137.11 | ASTM D 1785 ASTM D 2241 CSA B137.3 |
Loop piping | ‒ | ‒ | ASTM D 2239 ASTM D 2737 ASTM D 3035 NSF 358-1 | ASTM F 1282 | ASTM F 2623 ASTM F 2769 | ASTM F 876 CSA B137.5 | ‒ | ASTM F 2389 CSA B137.11 | ‒ | |
Gray water | Nonpressure distribution/ collection | ASTM F 628 | ‒ | ASTM D 2239 ASTM D 2737 ASTM D 3035 ASTM F 2306 | ‒ | ‒ | ‒ | ‒ | ASTM F 2389 CSA B137.11 | ASTM D 1785 ASTM D 2729 ASTM D 2949 ASTM D 3034 ASTM F 891 ASTM F 1760 CSA B137.3 |
(continued)
TABLE AG101.1‒continued PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa,b
APPLICATION | LOCATION | TYPE OF PLASTIC PIPING | ||||||||
ABS | CPVC | PE | PE-AL- PE | PE-RT | PEX | PEX-AL- PEX | PP | PVC | ||
Gray water | Pressure/ distribution | ‒ | ASTM D 2846 ASTM F 441 ASTM F 442 ASTM F 2855 CSA B137.6 | ASTM D 2239 ASTM D 2737 ASTM D 3035 | ASTM F 1282 | ASTM F 2623 ASTM F 2769 | ASTM F 876 CSA B137.5 | ASTM F 1281 | ASTM F 2389 CSA B137.11 | ASTM D 1785 ASTM D 2241 CSA B137.3 |
Radiant cooling | Loop piping | ‒ | ASTM D 2846 ASTM F 441 ASTM F 442 ASTM F 2855 | ASTM D 2239 ASTM D 2737 ASTM D 3035 | ASTM F 1282 | ASTM F 2623 ASTM F 2769 | ASTM F 876 CSA B137.5 | ASTM F 1281 | ASTM F 2389 CSA B137.11 | ‒ |
Radiant heating | Loop piping | ‒ | ASTM D 2846 ASTM F 441 ASTM F 442 ASTM F 2855 | ‒ | ASTM F 1282 | ASTM F 2623 ASTM F 2769 | ASTM F 876 CSA B137.5 | ASTM F 1281 | ASTM F 2389 CSA B137.11 | ‒ |
Rainwater harvesting | Nonpressure/ collection | ASTM F 628 | ‒ | ASTM F 1901 | ‒ | ‒ | ‒ | ‒ | ASTM F 2389 CSA B137.11 | ASTM D 1785 ASTM D 2729 ASTM D 2949 ASTM F 891 ASTM F 1760 CSA B137.3 |
Pressure/ distribution | ‒ | ASTM D 2846 ASTM F 441 ASTM F 442 ASTM F 2855 CSA B137.6 | ASTM D 2239 ASTM D 2737 ASTM D 3035 | ASTM F 1282 | ASTM F 2623 ASTM F 2769 | ASTM F 876 CSA B137.5 | ASTM F 1281 | ASTM F 2389 CSA B137.11 | ASTM D 1785 ASTM D 2241 CSA B137.3 |
(continued)
TABLE AG101.1‒continued PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa,b
APPLICATION | LOCATION | TYPE OF PLASTIC PIPING | ||||||||
ABS | CPVC | PE | PE-AL- PE | PE-RT | PEX | PEX-AL- PEX | PP | PVC | ||
Radon venting | System piping | ASTM F 628 | ‒ | ‒ | ‒ | ‒ | ‒ | ‒ | ‒ | ASTM D 1785 ASTM F 891 ASTM F 1760 |
Reclaimed water | Main to building service | ‒ | ASTM D 2846 ASTM F 441 ASTM F 442 ASTM F 2855 CSA B137.6 | ASTM D 3035 AWWA C901 CSA B137.1 | ASTM F 1282 | ASTM F 2623 ASTM F 2769 | ASTM F 876 AWWA C904 CSA B137.5 | ‒ | ASTM F 2389 CSA B137.11 | ASTM D 1785 ASTM D 2241 AWWA C905 CSA B137.3 |
Pressure/ distribution/ irrigation | ‒ | ASTM D 2846 ASTM F 441 ASTM F 442 ASTM F 2855 CSA B137.6 | ASTM D 2239 ASTM D 2737 ASTM D 3035 | ASTM F 1282 | ASTM F 2623 ASTM F 2769 | ASTM F 876 CSA B137.5 | ASTM F 1281 | ASTM F 2389 AWWA C900 CSA B137.11 | ASTM D 1785 ASTM D 2241 AWWA C900 | |
Residential fire sprinklersc | Sprinkler piping | ‒ | ASTM F 441 ASTM F 442 CSA B137.6 UL 1821 | ‒ | ‒ | ASTM F 2769 | ASTM F 876 CSA B137.5 UL 1821 | ‒ | ASTM F 2389 CSA B137.11 | ‒ |
Solar heating | Pressure/ distribution | ‒ | ASTM D 2846 ASTM F 441 ASTM F 442 ASTM F 2855 | ‒ | ‒ | ASTM F 2623 ASTM F 2769 | ASTM F 876 CSA B137.5 | ASTM F 1281 | ASTM F 2389 CSA B137.11 | ‒ |
a. This table indicates manufacturing standards for plastic piping materials that are suitable for use in the applications indicated. Such applications support green and sustainable building practices. The system designer or the installer of piping shall verify that the piping chosen for an application complies with local codes and the recommendations of the manufacturer of the piping. |
b. Fittings applicable for the piping shall be as recommended by the manufacturer of the piping. |
c.Piping systems for fire sprinkler applications shall be listed for the application. |
ASTM | |
F1760‒01(2011) | Standard Specification for Coextruded Poly (Vinyl Chloride) (PVC) Non- Pressure Plastic Pipe Having Reprocessed-Recycled Content |
F1901‒10 | Standard Specification for Polyethylene (PE) Pipe and Fittings for Roof Drain Systems |
F2158‒08 | Standard Specification for Residential Central-Vacuum Tube and Fittings |
F2306‒08 | 12" to 60" Annular Corrugated Profile- wall Polyethylene (PE) Pipe and Fittings for Gravity Flow Storm Sewer and Sub- surface Drainage Applications |
AWWA | |
900‒07 | Polyvinyl chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 in. through 12 in. (350 mm through 1200 mm), for Water Transmission and Distribution |
905‒10 | Polyvinyl chloride (PVC) Pressure Pipe and Fabricated Fittings, 14 in. through 48 in. (100 mm through 300 mm) |
UL | |
1821‒2011 | Standard for Thermoplastic Sprinkler Pipe and Fittings for Fire Protection Service |