Chapter 1 Scope and Administration

Chapter 2 Definitions

Chapter 3 Prescriptive Compliance Method

Chapter 4 Classification of Work

Chapter 5 Repairs

Chapter 6 Alterations - Level 1

Chapter 7 Alterations - Level 2

Chapter 8 Alterations - Level 3

Chapter 9 Change of Occupancy

Chapter 10 Additions

Chapter 11 Historic Buildings

Chapter 12 Relocated or Moved Buildings

Chapter 13 Performance Compliance Methods

Chapter 14 Construction Safeguards

Chapter 15 Referenced Standards

Chapter A1 Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings

Chapter A2 Earthquake Hazard Reduction in Existing Reinforced Concrete and Reinforced Masonry Wall Buildings With Flexible Diaphragms

Chapter A3 Prescriptive Provisions for Seismic Strengthening of Cripple Walls and Sill Plate Anchorage of Light, Woodframe Residential Buildings

Chapter A4 Earthquake Hazard Reduction in Existing Woodframe Residential Buildings With Soft, Weak or Openfront Walls

Chapter A5 A5 Earthquake Hazard Reduction in Existing Concrete Buildings

Appendix A Guidelines for the Seismic Retrofit of Existing Buildings

Appendix B Supplementary Accessibility Requirements for Existing Buildings and Facilities

Resource A1 Fire-Related Performance of Archaic Materials and Assemblies

Resource A2 Building Evaluation

Resouce A3 : Final Evaluation and Design Solution

Resource A4 Summary

Resource A Appendix : Table of Contents

Resource A Appendix: Section I - Walls

Resource A Appendix : Section II - Columns

Resource A Appendix : Section III - Floor/Ceiling Assemblies

Resource A Appendix : Section IV - Beams

Resource A Appendix : Section V - Doors

Bibliography

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

ASCE American Society of Civil Engineers Structural Engineering Institute 1801 Alexander Bell Drive Reston, VA 20191-4400
Standard reference number Title Referenced in code section number
7—05 Minimum Design Loads for Buildings and Other Structures with Supplement No. 1 101.5.4.1, A104, A506.1, A507.1
31—03 Seismic Evaluation of Existing Buildings 101.5.4, Table 101.5.4.1, 101.5.4.2
41—06 Seismic Rehabilitation of Existing Buildings Table 101.5.4.1, 101.5.4.2



ASHRAE American Society of Heating, Refrigerating and Air Conditioning Engineers 1791 Tullie Circle, NE Atlanta, GA 30329
Standard reference number Title Referenced in code section number
62—04 Ventilation for Acceptable Indoor Air Quality 709.2



ASME American Society of Mechanical Engineers 3 Park Avenue New York, NY 10016
Standard reference number Title Referenced in code section number
A17.1/CSA B44—2007 Safety Code for Elevators and Escalators 310.8.2, 605.1.2, 802.1.2
A17.3—2002 Safety Code for Existing Elevators and Escalators .802.1.2
A18.1—2005 Safety Standard for Platform Lifts and Stairway Chair Lifts 310.8.3, 605.1.3



ASTM ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959
Standard reference number Title Referenced in code section number
C 90—03 Standard Specification for Load-bearing Concrete Masonry Units A505.2.3
C 496—96 Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens A104, A106.3.3.2
E 519—00e1 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages A104, A106.3.3.2



DOC United States Department of Commerce 1401 Constitution Avenue, NW Washington, DC 20230
Standard reference number Title Referenced in code section number
PS 1—07 Structural Plywood A302
PS 2—04 Performance Standard for Wood-based Structural-use Panels A302



ICC International Code Council, Inc. 500 New Jersey Avenue, NW, 6th Floor Washington, DC 20001
Standard reference number Title Referenced in code section number
IBC—09 International Building Code® 101, 106, 109, 110, 202, 307, 310, 401, 501, 502, 506, 601, 602, 605, 606, 701, 702, 703, 704, 705, 706, 707, 804, 805, 807, 901, 902, 907, 911, 912, 1002, 1003, 1004, 1101, 1102, 1103, 1104, 1105, 1201, 1202, 1301, 1401, 1406
ICC A117.1—03 Guidelines for Accessible and Usable Buildings and Facilities 310.6, 310.8.2, 605.1, 605.1.2, 605.1.3,
IECC—09 International Energy Conservation Code® . 602.4, 607.1, 711.1, 808.1,
IFC—09 International Fire Code® 101.4.2, 101.5.1, 703.2.1, 703.2.3, 704.4.1.1, 704.4.1.2, 704.4.1.3, 704.4.1.4, 704.4.1.5, 704.4.1.6, 70, 4.4.1.7, 704.4.3, 1201.2, 1301.3.2, 1301.6.8.1, 1301.6.14, 1301.6.14.1, 1404.1, 1404.2,
IFGC—09 International Fuel Gas Code® 307.7, 602.4.1
IMC—09 International Mechanical Code® 307.8, 602.4, 709.1, 802.1.1, 802.2.1, 909.1, 1301.6.7.1, 1301.6.8, 1301.6.8.1
IPC—09 International Plumbing Code® 307.9, 509.1, 602.4, 710.1, 910.2, 910.3, 910.5, 1401.5
IPMC—09 International Property Maintenance Code®. 101.4.2, 1201.2, 1301.3.2
IRC—09 International Residential Code® 101.4.1, 502.3, 506, 606.2.1, 607.1, 707.4, 708.3, 711.1, 807.4, 807.4.2, 808.1, 1003.2, 1003.3, 1003.4, 1004.1, 1202.1, 1202.2, 1202.2.1, 1202.3, 1202.4, 1202.5, 1301.2.2, 1301.2.3



NFPA National Fire Protection Agency 1 Batterymarch Park Quincy, MA 02269-9101
Standard reference number Title Referenced in code section number
NFPA 13R—07 Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height 704.2.5
NFPA 70—05 National Electrical Code 507.1.1, 507.1.2, 507.1.3, 507.1.4, 507.1.5
NFPA 72—07 National Fire Alarm Code 704.2.5, 704.4
NFPA 99—05 Health Care Facilities 507.1.4
NFPA 101—06 Life Safety Code 705.2