ADOPTS WITH AMENDMENTS:

NFPA 1, 2018

Heads up: There are no amended sections in this chapter.
The storage, use, and handling of explosives, fireworks, and model rocketry shall comply with the requirements of this chapter, NFPA standards referenced within this chapter, and Sections 60.1 through 60.4 of this Code.
Where the provisions of this chapter or NFPA standards referenced herein conflict with the provisions of Chapter 60, the provisions of this chapter and referenced NFPA standards shall apply.

65.2 Display Fireworks

AMENDMENT
This section has been amended at the state or city level.
  1. All applications for permits for display shall be filed at least 10 business days before the display is to be held.
  2. Under Public Safety Article, Title 10, Annotated Code of Maryland, the following requirements apply to public liability and property damage insurance:
    1. In order to meet the requirement of the statute, the State shall be named as an insured in the contract of insurance;
    2. Because the policy shall cover all damages to persons or property, a deductible form of coverage may not be accepted;
    3. The minimum amount of coverage that the State can accept on any display is $25,000 for the injury of one person, $50,000 for more than one person, and $10,000 for property damage; and
    4. A duplicate policy of a certificate of insurance shall be attached to the application.
  3. The policy or certificate shall provide that:
    1. The coverage may not be canceled without at least 30 days notice to the State Fire Marshal;
    2. The duplicate policy or certificate shall set forth all of the terms, conditions, endorsements, and riders which are or which will become part of the policy when issued;
    3. It is understood and agreed that limitations cannot be included in the policy which are not set forth in the duplicate policy or certificate of insurance which has been filed;
    4. If the policy is issued by an insurer authorized to do business in the State, it shall be validated by the signature of an agent licensed by the Maryland Insurance Administration to represent the insurer;
    5. If coverage is provided by an insurer who is not authorized to do business in the State, the duplicate policy or certificate of insurance shall be accompanied by a power of attorney or other satisfactory evidence that the person, firm, or corporation acting as agent in accepting the risk has authority to bind risks and issue policies for the insurer;
    6. The State Fire Marshal's Office specifically reserves the right to disapprove contracts issued by any authorized insurer if the Fire Marshal's Office determines the insurer is unsatisfactory; and
    7. If the policy issued by the unauthorized company is acceptable to the Fire Marshal's Office, it shall be registered and the registration fee and tax paid.
The construction, handling, and use of fireworks intended solely for outdoor display as well as the general conduct and operation of the display shall comply with the requirements of NFPA 1123.
All storage of display fireworks shall comply with NFPA 1124.
Permits, where required, shall comply with Section 1.12.

65.3 Pyrotechnics Before a Proximate Audience

AMENDMENT
This section has been amended at the state or city level.
  1. All applications for permits for display shall be filed at least 10 business days before the display is to be held.
  2. Under Public Safety Article, Title 10, Annotated Code of Maryland, the following requirements apply to public liability and property damage insurance:
    1. In order to meet the requirement of the statute, the State shall be named as an insured in the contract of insurance;
    2. Because the policy shall cover all damages to persons or property, a deductible form of coverage may not be accepted;
    3. The minimum amount of coverage that the State can accept on any display is $25,000 for the injury of one person, $50,000 for more than one person, and $10,000 for property damage; and
    4. A duplicate policy of a certificate of insurance shall be attached to the application.
  3. The policy or certificate shall provide that:
    1. The coverage may not be canceled without at least 30 days notice to the State Fire Marshal;
    2. The duplicate policy or certificate shall set forth all of the terms, conditions, endorsements, and riders which are or which will become part of the policy when issued;
    3. It is understood and agreed that limitations cannot be included in the policy which are not set forth in the duplicate policy or certificate of insurance which has been filed;
    4. If the policy is issued by an insurer authorized to do business in the State, it shall be validated by the signature of an agent licensed by the Maryland Insurance Administration to represent the insurer;
    5. If coverage is provided by an insurer who is not authorized to do business in the State, the duplicate policy or certificate of insurance shall be accompanied by a power of attorney or other satisfactory evidence that the person, firm, or corporation acting as agent in accepting the risk has authority to bind risks and issue policies for the insurer;
    6. The State Fire Marshal's Office specifically reserves the right to disapprove contracts issued by any authorized insurer if the Fire Marshal's Office determines the insurer is unsatisfactory; and
    7. If the policy issued by the unauthorized company is acceptable to the Fire Marshal's Office, it shall be registered and the registration fee and tax paid.
The use of pyrotechnic special effects in the performing arts in conjunction with theatrical, musical, or any similar productions before a proximate audience, performers, or support personnel shall comply with NFPA 1126.
Where any of the following conditions exist, they shall comply with NFPA 1126:
  1. Any indoor display of pyrotechnic special effects
  2. Any outdoor use of pyrotechnic special effects at distances less than those required by NFPA 1123
  3. The use of pyrotechnic special effects during any videotaping, audiotaping, or filming of any television, radio, or movie production if such production is before a proximate audience
  4. The rehearsal of any production in which pyrotechnic special effects are used
Permits, where required, shall comply with Section 1.12.

65.4 Flame Effects Before an Audience

AMENDMENT
This section has been amended at the state or city level.
  1. All applications for permits for display shall be filed at least 10 business days before the display is to be held.
  2. Under Public Safety Article, Title 10, Annotated Code of Maryland, the following requirements apply to public liability and property damage insurance:
    1. In order to meet the requirement of the statute, the State shall be named as an insured in the contract of insurance;
    2. Because the policy shall cover all damages to persons or property, a deductible form of coverage may not be accepted;
    3. The minimum amount of coverage that the State can accept on any display is $25,000 for the injury of one person, $50,000 for more than one person, and $10,000 for property damage; and
    4. A duplicate policy of a certificate of insurance shall be attached to the application.
  3. The policy or certificate shall provide that:
    1. The coverage may not be canceled without at least 30 days notice to the State Fire Marshal;
    2. The duplicate policy or certificate shall set forth all of the terms, conditions, endorsements, and riders which are or which will become part of the policy when issued;
    3. It is understood and agreed that limitations cannot be included in the policy which are not set forth in the duplicate policy or certificate of insurance which has been filed;
    4. If the policy is issued by an insurer authorized to do business in the State, it shall be validated by the signature of an agent licensed by the Maryland Insurance Administration to represent the insurer;
    5. If coverage is provided by an insurer who is not authorized to do business in the State, the duplicate policy or certificate of insurance shall be accompanied by a power of attorney or other satisfactory evidence that the person, firm, or corporation acting as agent in accepting the risk has authority to bind risks and issue policies for the insurer;
    6. The State Fire Marshal's Office specifically reserves the right to disapprove contracts issued by any authorized insurer if the Fire Marshal's Office determines the insurer is unsatisfactory; and
    7. If the policy issued by the unauthorized company is acceptable to the Fire Marshal's Office, it shall be registered and the registration fee and tax paid.
The use of flame effects before an audience shall comply with NFPA 160.
Permits, where required, shall comply with Section 1.12.

65.5 Fireworks Manufacturing

AMENDMENT
This section has been amended at the state or city level.
  1. A building containing hazardous mixes or items may not be located closer than 20 feet to the property line.
  2. In §C(3) of this regulation, the following terms have the meanings indicated:
    1. "Trainees" means employees undergoing initial training in a specific process for a period not to exceed 24 consecutive work hours.
    2. "Transients" means:
      1. (Supervisors not regularly assigned to the area;
      2. Bona fide government agency personnel engaged in official business; and
      3. Material-handling personnel actively engaged in the transfer of materials into or out of the area.
  3. The maximum number of workers, excluding one trainee and three transients, permitted in a building at one time shall be limited to one person per 100 square feet gross floor area or one person in buildings of less than 100 square feet gross floor area.
  4. The total amount of explosives or pyrotechnic composition including raw materials, material being processed, and finished products, that may be safely permitted in any building at a given time, shall be determined by the enforcement agency based upon the American Table of Distances for Storage of Explosives, without recognition for barricades. However, distances may not be less than those required by Public Safety Article, §10-204(a), Annotated Code of Maryland. The amount of explosives or other pyrotechnic composition may not exceed the amount necessary for production for 4 hours.
  5. Before beginning work, all fireworks plants shall submit for approval accurate scale plot plans of their premises to the State Fire Marshal of all proposed changes of location of any of the structures, fences, and gates.
The manufacture, transportation, or storage of fireworks shall comply with NFPA 1124.
Permits, where required, shall comply with Section 1.12.

65.5.3

AMENDMENT
This section has been amended at the state or city level.
Sale or use of fireworks shall comply with the following:
  1. Before the sale, offering for sale, or use within the State, of any sparkler, every manufacturer of sparklers shall submit sufficient samples for inspection to the State Fire Marshal, with a laboratory report from a certified testing laboratory affirming that the analysis of these sparklers showed that they contain no chlorates or perchlorates.
  2. All sparklers sold in the State shall be sold in boxes, and each box shall be clearly marked that the sparklers contain no chlorates or perchlorates.
  3. The manufacturer shall furnish the State Fire Marshal with a current list of wholesalers, jobbers, retailers, or retail outlets, who handle or supply sparklers, or maintain a list of wholesalers, jobbers, retailers, or retail outlets, subject to inspection by the State Fire Marshal.
The design, construction, limitations of propellant mass and power, and reliability of model rocket motors and model rocket motor reloading kits and their components produced commercially for sale to or use by the public for purposes of education, recreation, and sporting competition shall comply with NFPA 1122.
The manufacture of model rocket motors designed, sold, and used for the purpose of propelling recoverable aero models shall comply with NFPA 1125.
Permits, where required, shall comply with Section 1.12.
The design, construction, limitations of propellant mass and power, and reliability of all high-power rocket motors and motor components produced commercially for sale to or use by the certified user for education, recreation, and sporting competition shall comply with NFPA 1127.
Permits, where required, shall comply with Section 1.12.

65.9.1

AMENDMENT
This section has been amended at the state or city level.
The manufacture, transportation, storage, sale, and use of explosive materials shall comply with NFPA 495 and NFPA 498.

Amend Subsection 65.9.1 reference to NFPA 495 as follows:
  1. Amend Section 3.3 to add the following definition: Demolition. The explosive razing of any manmade structure or any part thereof that cannot be covered with overburden or blasting mats.
  2. Amend Section 4.4 to add the following new Subsection: 4.4.7 Each applicant for a Demolition Class D permit shall possess 5 years of experience in the field of demolition and shall pass the demolition examination as approved by the Office of the State Fire Marshal.
Permits, where required, shall comply with Section 1.12.
A separate permit shall be required to conduct blasting operations.

65.10 Sale, Handling, and Storage of Consumer Fireworks

AMENDMENT
This section has been amended at the state or city level.

65.10.1 Applicability

AMENDMENT
This section has been amended at the state or city level.

65.10.1.1 General Requirements

AMENDMENT
This section has been amended at the state or city level.
Retail sales of consumer fireworks in both new and existing buildings, structures, and facilities shall comply with the requirements of this section unless otherwise indicated.

65.10.1.1.1 New Facilities

AMENDMENT
This section has been amended at the state or city level.

65.10.1.1.1.1

AMENDMENT
This section has been amended at the state or city level.
For the purpose of applying the requirements of this section, the following consumer fireworks retail sales(CFRS) facilities and stores shall be considered to be new:
  1. Permanent CFRS facilities and stores that are not initially occupied until after the effective date of this Code, unless plans are submitted and accepted for review, plans have been approved for construction, or a building permit has been issued prior to the effective date of this Code;
  2. Permanent CFRS facilities and stores constructed prior to the effective date of this Code and in which the retail sales of consumer fireworks have not been conducted either seasonally or year-round within one year prior to the effective date of this Code;
  3. Temporary CFRS facilities and stores.

65.10.1.1.1.2

AMENDMENT
This section has been amended at the state or city level.
In a store where the area of the retail sales floor occupied by the retail displays of consumer fireworks is increased after the effective date of this Code, such that the area exceeds the limits specified in 65.10.5.1.1(1), the building shall be considered to be a new CFRS facility.

65.10.1.1.2 Existing Facilities

AMENDMENT
This section has been amended at the state or city level.
For the purpose of applying the requirements of Section 65.10, CFRS facilities and stores not considered to be new as specified in 65.10.1.1.1 shall be considered to be existing.

65.10.1.1.3 Minimum Requirements

AMENDMENT
This section has been amended at the state or city level.
Existing life safety features that do not meet the requirements for new buildings but that exceed the requirements for existing buildings shall not be further diminished.

65.10.1.1.4 Modernization or Renovation

AMENDMENT
This section has been amended at the state or city level.
Any alteration or any installation of new equipment shall meet, as nearly as practicable, the requirements for new construction.

65.10.1.1.4.1

AMENDMENT
This section has been amended at the state or city level.
Only the altered, renovated, or modernized portion of an existing building, system, or individual component shall be required to meet the provisions of this Code that are applicable to new construction.

65.10.1.1.4.2

AMENDMENT
This section has been amended at the state or city level.
If the alteration, renovation, or modernization adversely impacts required life safety features, additional upgrading shall be required.

65.10.1.1.4.3

AMENDMENT
This section has been amended at the state or city level.
Except where another provision of this Code exempts a previously approved feature from a requirement, the resulting feature shall be not less than that required for existing buildings.

65.10.1.2 Facility Classification

AMENDMENT
This section has been amended at the state or city level.
The requirements of this section shall apply to the following:
  1. Permanent buildings and structures, including the following:
    1. Stores;
    2. CFRS facilities.
  2. Temporary facilities, including the following:
    1. CFRS stands;
    2. Tents;
    3. Canopies;
    4. Membrane structures.

65.10.2 Special Limits for Retail Sales of Consumer Fireworks

AMENDMENT
This section has been amended at the state or city level.

65.10.2.1

AMENDMENT
This section has been amended at the state or city level.
Retail sales of consumer fireworks, including their related storage and display for sale of such fireworks, shall be in accordance with this Code.

65.10.2.2

AMENDMENT
This section has been amended at the state or city level.
Retail sales of consumer fireworks shall be limited to mercantile occupancies defined in 3.3.183.17 and NFPA 101.

65.10.2.3

AMENDMENT
This section has been amended at the state or city level.
Any building or structure used for the retail sales of consumer fireworks, including their related storage, shall comply with Section 20.12 and NFPA 101 for mercantile occupancies, except as provided in this Code.

65.10.2.4

AMENDMENT
This section has been amended at the state or city level.
Retail sales of display fireworks and pyrotechnic articles, including the related storage and display for sale of such fireworks and articles, shall be prohibited at a CFRS facility or store.

65.10.2.5

AMENDMENT
This section has been amended at the state or city level.
Retail sales of certain explosive devices prohibited by the Child Safety Act of 1966, including the related storage and display for sale of such devices, shall be prohibited at a CFRS facility or store.

65.10.2.6

AMENDMENT
This section has been amended at the state or city level.
The retail sales of pest control devices, including their related storage and display for sale, shall be prohibited at a CFRS facility or store.

65.10.2.7

AMENDMENT
This section has been amended at the state or city level.
The retail sales of fireworks that do not comply with the regulations of the U.S. Consumer Product Safety Commission as set forth in 16 CFR 1500 and 1507 and the regulations of the U.S. Department of Transportation as set forth in 49 CFR 100 to 178, including their related storage and display for sale, shall be prohibited.

65.10.3 General Requirements for All Retail Sales

AMENDMENT
This section has been amended at the state or city level.

65.10.3.1 Exempt Amounts

AMENDMENT
This section has been amended at the state or city level.

65.10.3.1.1

AMENDMENT
This section has been amended at the state or city level.
The requirements of this section shall not apply to CFRS facilities or stores where the consumer fireworks are in packages and where the total quantity of consumer fireworks on hand does not exceed 125 lb. (net) [56.8 kg] of pyrotechnic composition or, in a building protected throughout with an approved automatic sprinkler system installed in accordance with Section 13.3 and NFPA 13, 250 lb. (net) [113.6 kg] of pyrotechnic composition.

65.10.3.1.2

AMENDMENT
This section has been amended at the state or city level.
Where the actual weight of the pyrotechnic composition of consumer fireworks is not known, 25 percent of the gross weight of the consumer fireworks, including packaging, shall be permitted to be used to determine the weight of the pyrotechnic composition.

65.10.3.2 Permits

AMENDMENT
This section has been amended at the state or city level.
Where required by state or local laws, ordinances, or regulations, a permit for the following shall be obtained:
  1. Construction, erection, or operation of the following:
    1. Permanent building or structure;
    2. Temporary structure such as a stand, tent, or canopy used for the purpose of the retail. display or sale of consumer fireworks to the public.
  2. Storage of consumer fireworks in connection with the retail display or sale of consumer fireworks to the public.

65.10.3.3 Plans

AMENDMENT
This section has been amended at the state or city level.
Plans for facilities other than stands and tents shall include the following:
  1. Minimum distances from the following:
    1. Public ways;
    2. Buildings;
    3. Other CFRS facilities;
    4. Motor vehicle fuel—dispensing station dispensers;
    5. Retail propane-dispensing station dispensers;
    6. Flammable and combustible liquid aboveground tank storage;
    7. Flammable gas and flammable liquefied gas bulk aboveground storage and dispensing areas within 300 ft (91.5 m) of the facility used for the retail sales of consumer fireworks.
  2. Vehicle access and parking areas.
  3. Location and type of portable fire extinguishers.
  4. Floor plan and layout of storage and displays to indicate compliance with this chapter and applicable state or local laws, ordinances, or regulations.
  5. Means of egress.
  6. Construction details.

65.10.3.4 Fire Department Access

AMENDMENT
This section has been amended at the state or city level.
Any portion of an exterior wall of a building, sidewall of a tent, or other defined perimeter of a CFRS facility or store shall be accessible within 150 ft (45.7 m) of a public way or an approved fire apparatus access.

65.10.3.5 Construction of Buildings and Structures

AMENDMENT
This section has been amended at the state or city level.
Consumer fireworks shall only be permitted to be sold at retail in any of the following buildings or structures, provided that any new building or structure does not exceed one story in height:
  1. Permanent buildings or structures constructed in accordance with the building code enforced by the AHJ;
  2. Tents, canopies, or temporary membrane structures complying with NFPA 102, Standard for Grandstands, Folding and Telescopic Seating, Tents, and Membrane Structures;
  3. Temporary structures constructed in accordance with this chapter;
  4. Temporary CFRS stands greater than 800 ft2 (74 m2) in area that also meet the requirements for a permanent structure;
  5. Vehicles, such as vans, buses, trailers, recreational vehicles, motor homes, travel trailers, trucks, and automobiles, complying with the applicable requirements for CFRS stands.

65.10.3.6

AMENDMENT
This section has been amended at the state or city level.
An automatic sprinkler system designed and installed in accordance with Section 13.3 and NFPA 13 shall be provided throughout permanent CFRS facilities and stores in which CFRS are conducted in the following buildings:
  1. New buildings greater than 6000 ft2 (557.2 m2) in area;
  2. Existing buildings greater than 7500 ft2 (694 m2) in area.

65.10.3.6.1

AMENDMENT
This section has been amended at the state or city level.
Door and window openings in the fire barrier wall shall be protected by self-closing fire doors or fixed fire windows having a fire protection rating of not less than 1 hour and shall be installed in accordance with Section 12.4 and NFPA 80, Standard for Fire Doors and Other Opening Protectives.

65.10.3.6.2

AMENDMENT
This section has been amended at the state or city level.
Any other openings or penetrations in the fire barrier wall shall be protected in accordance with NFPA 101.

65.10.3.6.3

AMENDMENT
This section has been amended at the state or city level.
Every CFRS facility and store shall have no fewer than two portable fire extinguishers with a minimum rating of 2A, at least one of which shall be of the pressurized water type.

65.10.3.7 Storage Rooms

AMENDMENT
This section has been amended at the state or city level.
Storage rooms containing consumer fireworks in a new permanent CFRS facility or store shall be protected with an automatic sprinkler system installed in accordance with Section 13.3 and NFPA 13 or separated from the retail sales area by a fire barrier having a fire resistance rating of not less than 1 hour.

65.10.3.8 Portable Fire Extinguishers

AMENDMENT
This section has been amended at the state or city level.

65.10.3.8.1 Specification

AMENDMENT
This section has been amended at the state or city level.
Portable fire extinguishers shall be provided as required for extra (high) hazard occupancy in accordance with Section 13.6 and NFPA 10.

65.10.3.8.2 Extinguisher Type

AMENDMENT
This section has been amended at the state or city level.
Where more than one portable fire extinguisher is required, at least one fire extinguisher shall be of the multipurpose dry chemical type if the facility is provided with electrical power.

65.10.3.8.3 Location

AMENDMENT
This section has been amended at the state or city level.
Portable fire extinguishers for permanent consumer fireworks retail sales facilities and stores shall be located so that the maximum distance of travel required to reach an extinguisher from any point does not exceed 75 ft (23 m), as specified in NFPA 10.

65.10.3.9 Fire Alarms

AMENDMENT
This section has been amended at the state or city level.
A fire alarm system shall be provided as required by Section 13.7 and NFPA 101.

65.10.3.10 Smoke Control

AMENDMENT
This section has been amended at the state or city level.

65.10.3.10.1

AMENDMENT
This section has been amended at the state or city level.
Smoke and heat vents designed and installed in accordance with NFPA 204, Standard for Smoke and Heat Venting, shall be provided in the CFRS area of new permanent CFRS facilities or stores where the ceiling height is less than 10 ft(3.05 m) and the travel distance to reach an exit is greater than 25 ft (7.6 m).

65.10.3.10.2

AMENDMENT
This section has been amended at the state or city level.
The smoke and heat vents required by 65.10.3.10.1 shall be automatically activated by a smoke detection system installed throughout the CFRS area in accordance with NFPA 72.

65.10.3.11 No Smoking Signs

AMENDMENT
This section has been amended at the state or city level.

65.10.3.11.1

AMENDMENT
This section has been amended at the state or city level.
Smoking shall not be permitted inside or within 50 ft (15.5 m) of the CFRS area.

65.10.3.11.2

AMENDMENT
This section has been amended at the state or city level.
At least one sign that reads as follows, in letters at least 2 in. (51 mm) high on a contrasting background, shall be conspicuously posted at each entrance or within 10 ft (3.05m) of every aisle directly serving the CFRS area in a store: "FIREWORKS — NO SMOKING"

65.10.3.12 Distance From Bulk Dispensing and Bulk Storage

AMENDMENT
This section has been amended at the state or city level.

65.10.3.12.1

AMENDMENT
This section has been amended at the state or city level.
CFRS facilities and stores shall not be located within 50 ft (15.2 m) of the following:
  1. Retail propane-dispensing station dispensers;
  2. Aboveground storage tanks for flammable or combustible liquid, flammable gas, or flammable liquefied gas;
  3. Compressed natural gas—dispensing station dispensers.

65.10.3.12.2

AMENDMENT
This section has been amended at the state or city level.
New CFRS facilities and stores, existing CFRS stands and tents, and temporary CFRS facilities shall not be located within 50 ft (15.2 m) of motor vehicle fuel—dispensing station dispensers.

65.10.3.12.3

AMENDMENT
This section has been amended at the state or city level.
Existing CFRS facilities, other than CFRS stands, tents, and temporary facilities, and existing stores shall not be located within 25 ft (7.6 m) of motor vehicle fuel—dispensing station dispensers.

65.10.3.12.4

AMENDMENT
This section has been amended at the state or city level.
Fuel tanks on vehicles or other motorized equipment shall not be considered bulk storage.

65.10.3.12.5

AMENDMENT
This section has been amended at the state or city level.
Fuel storage for generators shall be in accordance with 65.10.4.9.2.

65.10.3.12.6

AMENDMENT
This section has been amended at the state or city level.
CFRS areas and storage areas shall not be located within 300 ft (91.2 m) of any aboveground bulk storage or bulk dispensing area for the following:
  1. Flammable or combustible liquid;
  2. Flammable gas;
  3. Flammable liquefied gas.

65.10.3.13 Fire Safety and Evacuation Plan

AMENDMENT
This section has been amended at the state or city level.
For a CFRS facility or store, an approved fire safety and evacuation plan shall be prepared in writing and maintained current.

65.10.3.14 Means of Egress

AMENDMENT
This section has been amended at the state or city level.

65.10.3.14.1 Number of Exits

AMENDMENT
This section has been amended at the state or city level.

65.10.3.14.1.1

AMENDMENT
This section has been amended at the state or city level.
The minimum number of exits provided from the retail sales area shall be not less than three or as determined in accordance with Chapter 14 and NFPA 101, whichever number is greater.

65.10.3.14.1.2

AMENDMENT
This section has been amended at the state or city level.
Required means of egress from the retail sales area shall not be allowed to pass through storage rooms.

65.10.3.14.2 Egress Travel Distance

AMENDMENT
This section has been amended at the state or city level.
Exits provided for the retail sales area of tents, membrane structures, canopies, and permanent CFRS facilities, including Class C stores, shall be located so that the maximum egress travel distance, measured from the most remote point to an exit along the natural and unobstructed path of egress travel, does not exceed 75 ft (22.9 m). 

65.10.3.14.3 Aisles

AMENDMENT
This section has been amended at the state or city level.
Aisles serving as a portion of the exit access in CFRS areas shall comply with this paragraph.

65.10.3.14.3.1 Aisle Width

AMENDMENT
This section has been amended at the state or city level.

65.10.3.14.3.1.1

AMENDMENT
This section has been amended at the state or city level.
Aisles shall have a minimum clear width of 48 in. (1.2 m)

65.10.3.14.3.1.2

AMENDMENT
This section has been amended at the state or city level.
The required width of aisles shall be maintained unobstructed at all times the facility is occupied by the public.

65.10.3.14.3.2 Aisle Arrangements

AMENDMENT
This section has been amended at the state or city level.

65.10.3.14.3.2.1

AMENDMENT
This section has been amended at the state or city level.
Not less than one aisle shall be provided and arranged so that travel along the aisle leads directly to an exit.

65.10.3.14.3.2.2

AMENDMENT
This section has been amended at the state or city level.
Other required exits shall be located at, or within 10 ft (3.05 m) of, the end of an aisle or a cross-aisle

65.10.3.14.3.2.3

AMENDMENT
This section has been amended at the state or city level.
Aisles shall terminate at an exit, another aisle, or a cross-aisle.

65.10.3.14.3.2.4

AMENDMENT
This section has been amended at the state or city level.
Dead-end aisles shall be prohibited.

65.10.3.14.3.2.5

AMENDMENT
This section has been amended at the state or city level.
Where more than one aisle is provided, not less than one cross-aisle shall have an unobstructed connection with every aisle, other than cross-aisles.

65.10.3.14.3.2.6

AMENDMENT
This section has been amended at the state or city level.
Cross-aisle connections shall be provided for each aisle at intervals not greater than 50 ft (15.2 m) as measured along the aisle.

65.10.3.14.3.2.7

AMENDMENT
This section has been amended at the state or city level.
Where cross-aisles are required, not less than one cross-aisle shall have at least one end terminate at, or within 10 ft (3.05 m) of, an exit.

65.10.3.14.4 Doors and Doorways

AMENDMENT
This section has been amended at the state or city level.
Doors and doorways used in the means of egress shall comply with this paragraph.

65.10.3.14.4.1

AMENDMENT
This section has been amended at the state or city level.
Egress doors shall be not less than 36 in. (910 mm) in width [providing a minimum of 32 in. (813 mm) clear width].

65.10.3.14.4.2

AMENDMENT
This section has been amended at the state or city level.
Every egress door that has a latching device shall be provided with panic hardware complying with Chapter 14 and NFPA 101.

65.10.3.14.4.3

AMENDMENT
This section has been amended at the state or city level.
Means of egress doors shall be of the sidehinge swinging type and shall be arranged to swing in the direction of egress travel.

65.10.3.14.5 Exit Signs

AMENDMENT
This section has been amended at the state or city level.

65.10.3.14.5.1

AMENDMENT
This section has been amended at the state or city level.
Exits shall be marked by an approved exit sign in accordance with Section 14.14 and NFPA 101.

65.10.3.14.5.2

AMENDMENT
This section has been amended at the state or city level.
Exit signs shall be required to be self-luminous or internally or externally illuminated.

65.10.3.14.6 Emergency Lighting

AMENDMENT
This section has been amended at the state or city level.

65.10.3.14.6.1

AMENDMENT
This section has been amended at the state or city level.
The means of egress, including the exit discharge, shall be illuminated whenever the facility is occupied in accordance with Section 14.12 and NFPA 101.

65.10.3.14.6.2

AMENDMENT
This section has been amended at the state or city level.
Emergency lighting shall be provided for CFRS facilities and stores and shall comply with Section 14.13 and NFPA 101.

65.10.3.15 Retail Sales Displays

AMENDMENT
This section has been amended at the state or city level.

65.10.3.15.1 General

AMENDMENT
This section has been amended at the state or city level.
The requirements of this section shall apply only to CFRS areas, unless otherwise specifically indicated.

65.10.3.15.2 Height of Sales Displays

AMENDMENT
This section has been amended at the state or city level.
To provide for visual access of the retail sales area by the employees and customers, partitions, counters, shelving, cases, and similar space dividers shall not exceed 6 ft (1.8 m) in height above the floor surface inside the perimeter of the retail sales area.

65.10.3.15.2.1

AMENDMENT
This section has been amended at the state or city level.
Merchandise on display or located on shelves or counters or other fixtures shall not be displayed to a height greater than 6 ft (1.8 m) above the floor surface within the CFRS area.

65.10.3.15.2.2

AMENDMENT
This section has been amended at the state or city level.
Where located along the perimeter of the consumer fireworks retail sales area, the maximum height of sales displays shall be limited to 12 ft (3.66 m).

65.10.3.15.3 Flame Breaks

AMENDMENT
This section has been amended at the state or city level.

65.10.3.15.3.1

AMENDMENT
This section has been amended at the state or city level.
Where continuous displays of consumer fireworks are located on shelving, cases, counters, and similar display fixtures, a flame break shall be provided so that the maximum distance between flame breaks does not exceed 16 ft (4.9 m) where measured along the length of the display.

65.10.3.15.3.2

AMENDMENT
This section has been amended at the state or city level.
The flame break shall extend as follows:
  1. From the display surface to not less than 6 in. (150 mm) above the full height of the displayed merchandise or to the underside of the display surface directly above;
  2. For the full depth of the displayed merchandise.

65.10.3.15.3.3

AMENDMENT
This section has been amended at the state or city level.
Where packaged fireworks merchandise is displayed on the same level as individual unpackaged fireworks devices, the flame break required in 65.10.3.15.3.1 shall not be required where both of the following criteria are met:
  1. The length of the display level containing individual unpackaged fireworks devices is interrupted by packaged fireworks merchandise, or open space, or any combination thereof, having a continuous length of not less than 8 ft (2.4 m).
  2. The distance between flame breaks does not exceed 32 ft (9.8 m).

65.10.3.15.3.4

AMENDMENT
This section has been amended at the state or city level.
Where a merchandise display level contains packaged fireworks merchandise, such merchandise shall be permitted to be displayed in a continuous length on the same level, where the display does not exceed 32 ft (9.8 m) without the flame break required in 65.10.3.15.3.1.

65.10.3.15.3.5

AMENDMENT
This section has been amended at the state or city level.
An aisle having a minimum width of 48 in. (1.2 m) shall be permitted to substitute for the flame break required in 65.10.3.15.3.1.

65.10.3.15.3.6

AMENDMENT
This section has been amended at the state or city level.
Where displays of merchandise face aisles that run along both long sides of the display fixtures or display surface, a flame break shall be installed lengthwise between the abutting display fixtures or along the approximate longitudinal centerline of the display surface so as to separate the merchandise facing one of the aisles from the merchandise that abuts it facing the other aisle.

65.10.3.15.3.7

AMENDMENT
This section has been amended at the state or city level.
Freestanding display racks, pallets, tables, or bins containing packaged fireworks merchandise shall be permitted without flame breaks, provided the dimensions of the area occupied by the fireworks merchandise do not exceed 4 ft (1.2 m) in width, 8 ft (2.4 m) in length, and 6 ft (1.8 m) in height, and the displayed fireworks merchandise is separated from other displays of merchandise by aisles having a minimum clear width of 4 ft (1.2 m).

65.10.3.15.3.8

AMENDMENT
This section has been amended at the state or city level.
Where both of the facing vertical surfaces of the abutting display fixtures are constructed of perforated hardboard panels not less than 1/4 in. (6 mm) thick that are separated from each other by an open space not less than 11/2 in. (38 mm) wide, a flame break specified in 65.10.3.15.3.6 shall not be required.

65.10.3.15.4 Shelving

AMENDMENT
This section has been amended at the state or city level.

65.10.3.15.4.1

AMENDMENT
This section has been amended at the state or city level.
Shelving or other surfaces used to support fireworks display merchandise shall be permitted to have not more than 10 percent of the area of the shelf contain holes or other openings.

65.10.3.15.4.2

AMENDMENT
This section has been amended at the state or city level.
The 10 percent limitation on the area of holes or other openings in the shelf used to support fireworks display merchandise shall not be applicable under the following conditions:
  1. Where both of the facing vertical surfaces of the abutting display fixtures are constructed of perforated hardboard panels not less than 1/4 in. (6 mm) thick and separated from each other by an open space not less than 1 1/2 in. (38 mm) wide;
  2. Where such merchandise is suspended from or fastened to the shelf or surface or is displayed as packaged merchandise on the surface or in bins.

65.10.3.15.4.3

AMENDMENT
This section has been amended at the state or city level.
Flame breaks and solid display surfaces shall not be required for packaged fireworks merchandise displayed in bins or display racks or on pallets or tables located at the end of a row of display fixtures where the following conditions are met:
  1. Such end displays are separated from the ends of the display fixtures by an open space not less than 3 in. (76 mm) wide;
  2. The fireworks merchandise occupies an area having dimensions not greater than the width of the end of the row of display fixtures and a depth not greater than 36 in. (910 mm);
  3. The minimum required widths of the adjacent aisles are maintained, but in no case is the aisle width less than 48 in. (1.2 m).

65.10.3.15.5 Covered Fuses

AMENDMENT
This section has been amended at the state or city level.

65.10.3.15.5.1

AMENDMENT
This section has been amended at the state or city level.
Only consumer fireworks meeting the criteria for covered fuses as described in 65.10.3.15.5.2 shall be permitted where the retail sales of consumer fireworks are conducted.

65.10.3.15.5.2

AMENDMENT
This section has been amended at the state or city level.
A consumer fireworks device shall be considered as having a covered fuse if the fireworks device is contained within a packaged arrangement, container, or wrapper that is arranged and configured such that the fuse of the fireworks device cannot be touched directly by a person handling the fireworks without the person having to puncture or tear the packaging or wrapper, unseal or break open a package or container, or otherwise damage or destroy the packaging material, wrapping, or container within which the fireworks are contained.

65.10.3.15.6 Reserved

AMENDMENT
This section has been amended at the state or city level.

65.10.3.15.7 Horizontal Barriers

AMENDMENT
This section has been amended at the state or city level.
Combustible materials and merchandise shall not be stored directly above the consumer fireworks in retail sales displays unless a horizontal barrier constructed of plywood at least 9.5 mm (3/8 in.) thick is installed directly above the consumer fireworks as follows:
  1. Barriers shall extend from rack face to rack face and shall be tight to the vertical barriers;
  2. Barriers shall be supported by horizontal rack members;
  3. Transverse vertical barriers constructed of plywood at least 9.5 mm (3/8 in.) thick shall be provided at the rack uprights extending from rack face to rack face;
  4. For double-row racks, longitudinal vertical barriers constructed of plywood at least 9.5 mm (3/8 in.) thick shall be provided at the rack uprights in the center of the rack.

65.10.3.16 Electrical Equipment

AMENDMENT
This section has been amended at the state or city level.
All electrical wiring shall be in accordance with NFPA 70.

65.10.3.17 Heating Equipment

AMENDMENT
This section has been amended at the state or city level.

65.10.3.17.1

AMENDMENT
This section has been amended at the state or city level.
Heating units shall be listed and shall be used in accordance with their listing.

65.10.3.17.2

AMENDMENT
This section has been amended at the state or city level.
Temporary heating sources shall have tip-over and temperature-overheat protection.

65.10.3.17.3

AMENDMENT
This section has been amended at the state or city level.
Open-flame and exposed-element heating devices shall be prohibited.

65.10.3.18 Portable Generators

AMENDMENT
This section has been amended at the state or city level.

65.10.3.18.1

AMENDMENT
This section has been amended at the state or city level.
Class II and Class III combustible liquid generator fuel shall be limited to not more than 5 gal (18.9 L).

65.10.3.18.2

AMENDMENT
This section has been amended at the state or city level.
Portable generators shall be permitted to use Class I flammable liquids as fuel, provided the quantity of such fuel is limited to 2 gal (7.6 L).

65.10.3.19 Operations

AMENDMENT
This section has been amended at the state or city level.

65.10.3.19.1 General

AMENDMENT
This section has been amended at the state or city level.
Means of egress, including but not limited to aisles, doors, and exit discharge, shall be clear at all times when the facility or the building is occupied.

65.10.3.19.2 Distances From Entrances and Exits

AMENDMENT
This section has been amended at the state or city level.

65.10.3.19.2.1

AMENDMENT
This section has been amended at the state or city level.
No consumer fireworks shall be displayed for sale or stored within 5 ft (1.5 m) of any public entrance in an enclosed building or structure.

65.10.3.19.2.2

AMENDMENT
This section has been amended at the state or city level.
No consumer fireworks shall be displayed for sale or stored within 2 ft (0.6 m) of any exit or private entrance in an enclosed building or structure.

65.10.3.19.3 Security

AMENDMENT
This section has been amended at the state or city level.

65.10.3.19.3.1

AMENDMENT
This section has been amended at the state or city level.
CFRS facilities and stores shall be secured when unoccupied and not open for business, unless fireworks are not kept in the facility during such times.

65.10.3.19.3.2

AMENDMENT
This section has been amended at the state or city level.
The fireworks displayed or stored in a CFRS facility or store shall be allowed to be removed and transferred to a temporary storage structure or location.

65.10.3.19.4

AMENDMENT
This section has been amended at the state or city level.
Fireworks shall not be ignited, discharged, or otherwise used within 300 ft (91.5 m) of a CFRS facility or store.

65.10.3.20 Display and Handling

AMENDMENT
This section has been amended at the state or city level.
Not less than 50 percent of the available floor area within the retail sales area shall be open space that is unoccupied by retail displays and used only for aisles and cross-aisles.

65.10.3.21 Housekeeping

AMENDMENT
This section has been amended at the state or city level.

65.10.3.21.1

AMENDMENT
This section has been amended at the state or city level.
CFRS areas and storage rooms shall be kept free of accumulations of debris and rubbish.

65.10.3.21.2

AMENDMENT
This section has been amended at the state or city level.
Any loose pyrotechnic composition shall be removed immediately.

65.10.3.21.3

AMENDMENT
This section has been amended at the state or city level.
Vacuum cleaners or other mechanical cleaning devices shall not be used.

65.10.3.21.4

AMENDMENT
This section has been amended at the state or city level.
Brooms, brushes, and dustpans used to sweep up any loose powder or dust shall be made of nonsparking materials.

65.10.3.21.5

AMENDMENT
This section has been amended at the state or city level.
Consumer fireworks devices that are damaged shall be removed and not offered for sale.

65.10.3.21.6

AMENDMENT
This section has been amended at the state or city level.
Damaged consumer fireworks shall be permitted to be returned to the dealer or shall be disposed of according to the manufacturer's instructions.

65.10.3.22 Training

AMENDMENT
This section has been amended at the state or city level.
All personnel handling consumer fireworks shall receive safety training related to the performance of their duties.

65.10.3.23 Under the Influence

AMENDMENT
This section has been amended at the state or city level.
Any person selling consumer fireworks shall not knowingly sell consumer fireworks to any person who is obviously under the influence of alcohol or drugs.

65.10.3.24 Records

AMENDMENT
This section has been amended at the state or city level.

65.10.3.24.1

AMENDMENT
This section has been amended at the state or city level.
Records shall be maintained on available inventory on the premise.

65.10.3.24.2

AMENDMENT
This section has been amended at the state or city level.
Records shall be made available to the AHJ upon request.

65.10.4 Consumer Fireworks Retail Sales (CFRS) Facility Requirements

AMENDMENT
This section has been amended at the state or city level.

65.10.4.1 Plan

AMENDMENT
This section has been amended at the state or city level.
Where required, plans for CFRS facilities shall be submitted to the AHJ with the permit application.

65.10.4.2 Site Plan

AMENDMENT
This section has been amended at the state or city level.
The site plan for tents shall show the location of the tent on the site and indicate the minimum separation distances required by 65.10.4.7.

65.10.4.3 Construction Materials

AMENDMENT
This section has been amended at the state or city level.
The following construction materials requirements shall apply to new permanent CFRS facilities in jurisdictions that have not adopted a local building code:
  1. Buildings having an area up to and including 8000 ft2 (743 m2) shall be permitted to be constructed of any approved construction materials;
  2. Buildings having an area greater than 8000 ft2 (743 m2) shall be constructed in accordance with one of the following:
    1. Buildings shall be constructed of noncombustible or limited-combustible materials;
    2. Buildings with exterior walls having a fire resistance rating of not less than 2 hours shall be permitted to have the roof decking and its supporting structure and interior partitions constructed of combustible materials.
  3. Roof coverings for any building shall have a minimum rating of Class C.

65.10.4.4 Multiple-Tenant Buildings

AMENDMENT
This section has been amended at the state or city level.

65.10.4.4.1

AMENDMENT
This section has been amended at the state or city level.
Where new CFRS facilities are located in a building containing other tenants, the CFRS facility shall be separated from the other tenants by fire barriers having no openings and a fire resistance rating of not less than 2 hours.

65.10.4.4.2

AMENDMENT
This section has been amended at the state or city level.
Where the new CFRS facility is protected per Section 13.3 and NFPA 13, the fire resistance rating of the fire barrier required by 65.10.4.4.1 shall be permitted to be not less than 1 hour

65.10.4.4.3

AMENDMENT
This section has been amended at the state or city level.
Any penetrations of the fire barrier shall be protected in accordance with NFPA 101.

65.10.4.5 Fire Protection

AMENDMENT
This section has been amended at the state or city level.

65.10.4.5.1 Automatic Sprinkler System Alarm

AMENDMENT
This section has been amended at the state or city level.
Any waterflow alarm device shall be arranged to activate audible and visual alarms throughout the CFRS facility in accordance with Section 13.7 and NFPA 72.

65.10.4.5.2 Portable Fire Extinguishers

AMENDMENT
This section has been amended at the state or city level.
Portable fire extinguishers for temporary CFRS facilities shall be installed and located so that the maximum distance of travel required to reach an extinguisher from any point does not exceed 35 ft (10.6 m).

65.10.4.5.3 Public Notification

AMENDMENT
This section has been amended at the state or city level.
In permanent CFRS facilities greater than 3000 ft2 (278.6 m2) in area, a public address system or a means for manually activating audible and visible alarm indicating devices located throughout the facility in accordance with Section 13.7 and NFPA 72 shall be provided at a constantly attended location when the CFRS facility is occupied.

65.10.4.6 Site Requirements

AMENDMENT
This section has been amended at the state or city level.

65.10.4.6.1 Clearance to Combustibles

AMENDMENT
This section has been amended at the state or city level.
The area located within 30 ft (9 m) of a CFRS facility shall be kept free of accumulated dry grass, dry brush, and combustible debris.

65.10.4.6.2 Parking

AMENDMENT
This section has been amended at the state or city level.
No motor vehicle or trailer used for the storage of consumer fireworks shall be parked within 10 ft (3 m) of a CFRS facility, except when delivering, loading, or unloading fireworks or other merchandise and materials used, stored, or displayed for sale in the facility.

65.10.4.6.3 Fireworks Discharge

AMENDMENT
This section has been amended at the state or city level.
At least one sign that reads as follows, in letters at least 4 in. (102 mm) high on a contrasting background, shall be conspicuously posted on the exterior of each side of the CFRS facility: "NO FIREWORKS DISCHARGE WITHIN 300 FEET"

65.10.4.7 Separation Distances

AMENDMENT
This section has been amended at the state or city level.

65.10.4.7.1 Permanent Facilities

AMENDMENT
This section has been amended at the state or city level.

65.10.4.7.1.1 New Facilities

AMENDMENT
This section has been amended at the state or city level.

New permanent consumer fireworks retail sales facilities shall be separated from adjacent permanent buildings and structures in accordance with Table 65.10.4.7.1.1.

Table 65.10.4.7.1.1 Separation Distances Between New Permanent Buildings and Structures
Separation Distances Exterior Wall
Fire Resistance
Rating (hr)
Exterior Wall
Opening Protection
Rating (hr)
ft m
<10 <3.05  2 1 1/2
≥10 to <60 ≥3.05 to <18.3 1 3/4
≥60 ≥18.3  0 0

65.10.4.7.1.2 Existing Facilities

AMENDMENT
This section has been amended at the state or city level.
Existing permanent CFRS facilities shall be separated from adjacent permanent buildings and structures by not less than 10 ft (3.05 m) or shall be separated by a wall with a 1-hour fire resistance rating.

65.10.4.7.2 Temporary Facilities

AMENDMENT
This section has been amended at the state or city level.
Temporary CFRS facilities shall be located as specified in Table 65.10.4.7.2.
Table 65.10.4.7.2 Temporary CFRS Facilities — Minimum Separation Distances
  Buildings  Combustiblesa Tentsb Vehicle Parking Standsc Storage of
Consumer
Fireworks
ft m ft m ft m ft m ft m ft m
Tentsb 20 6.1 20 6.1 20 6.1 10 3.05 20 6.1 20 6.1
Standsc 20 6.1 10 3.05 20 6.1 10 3.05 5d 1.5d 20 6.1
  1. The required clearances to combustibles shall also comply with 65.10.4.6.1.
  2. Tents refers to temporary retail sales of consumer fireworks in tents, canopies, and membrane structures.
  3. Stands refers to temporary CFRS stands.
  4. Where stands are separated from each other by less than 20 ft (6.1 m), the aggregate area of such stands shall not exceed 800 ft2 (74 m2).

65.10.4.8 Means of Egress

AMENDMENT
This section has been amended at the state or city level.

65.10.4.8.1 General

AMENDMENT
This section has been amended at the state or city level.

65.10.4.8.1.1

AMENDMENT
This section has been amended at the state or city level.
Means of egress in CFRS facilities shall comply with the applicable requirements of Chapter 14 and NFPA 101, as modified by 65.10.3.14 and 65.10.4.8.

65.10.4.8.1.2

AMENDMENT
This section has been amended at the state or city level.
Means of egress in tents and membrane structures used for retail sales of consumer fireworks shall also comply with NFPA 102, as modified by 65.10.3.14 and 65.10.4.8.

65.10.4.8.2

AMENDMENT
This section has been amended at the state or city level.
The evacuation plan shall be posted in a conspicuous location that is accessible to the public as well as to persons employed or otherwise working in the CFRS facility.

65.10.4.8.3

AMENDMENT
This section has been amended at the state or city level.
Exit signs shall not be required to be illuminated in tents that are not open for business after dusk.

65.10.4.8.4

AMENDMENT
This section has been amended at the state or city level.
Emergency lighting shall not be required in tents that are not open for business after dusk.

65.10.4.8.5

AMENDMENT
This section has been amended at the state or city level.
Exit openings from tents shall have a clear opening width of not less than 44 in. (1100 mm).

65.10.4.9 Source of Ignition

AMENDMENT
This section has been amended at the state or city level.

65.10.4.9.1 Temporary Electrical Equipment

AMENDMENT
This section has been amended at the state or city level.
Battery powered equipment, electrical equipment, and electrical cords that are used in conjunction with a CFRS facility area shall be listed and shall be used in accordance with their listing.

65.10.4.9.1.1

AMENDMENT
This section has been amended at the state or city level.
Temporary wiring installed in a temporary structure, including tents and canopies, shall comply with NFPA 70.

65.10.4.9.1.2

AMENDMENT
This section has been amended at the state or city level.
Where temporary electrical conductors are placed on top of an outdoor surface to connect the permanent power source to the temporary CFRS facility's temporary electrical system, the conductors shall be provided with physical protection against damage caused by pedestrian or vehicular traffic.

65.10.4.9.2 Portable Generators

AMENDMENT
This section has been amended at the state or city level.

65.10.4.9.2.1

AMENDMENT
This section has been amended at the state or city level.
Portable generators supplying power to CFRS facilities shall use only Class II or Class III combustible liquid fuels.

65.10.4.9.2.2

AMENDMENT
This section has been amended at the state or city level.
Portable generators shall be located not less than 20 ft (6.1 m) from the CFRS facility.

65.10.4.9.2.3

AMENDMENT
This section has been amended at the state or city level.
Generator fuels shall be stored not less than 20 ft (6.1 m) from the CFRS facility.

65.10.4.9.2.4

AMENDMENT
This section has been amended at the state or city level.
Where the generator fuel storage is located not less than 50 ft (15.2 m) from the CFRS facility, the quantity of such fuel shall not be limited by 65.10.3.18.

65.10.4.9.3 Cooking Equipment

AMENDMENT
This section has been amended at the state or city level.

65.10.4.9.3.1

AMENDMENT
This section has been amended at the state or city level.
Cooking equipment of any type shall not be permitted within 20 ft (6.1 m) of tents, canopies, or membrane structures used for the storage or sale of consumer fireworks.

65.10.4.9.3.2

AMENDMENT
This section has been amended at the state or city level.
Open flame cooking equipment of any type shall not be allowed within 50 ft (15.2 m) of tents, canopies, or membrane structures used for the storage or sale of consumer fireworks.

65.10.4.10 Quantity Limitations

AMENDMENT
This section has been amended at the state or city level.
The floor area occupied by the retail displays of consumer fireworks in permanent CFRS facilities shall not exceed 40 percent of the available floor area within the retail sales area.

65.10.4.11 Flame Breaks

AMENDMENT
This section has been amended at the state or city level.
In CFRS facilities the longitudinal flame break required in 65.10.3.15.3.6 shall not be required where the display fixture or surface is adjacent to an aisle that is not used for public egress.

65.10.5 Stores

AMENDMENT
This section has been amended at the state or city level.

65.10.5.1 General

AMENDMENT
This section has been amended at the state or city level.

65.10.5.1.1

AMENDMENT
This section has been amended at the state or city level.
For the purpose of this chapter, stores in which retail sales of consumer fireworks are conducted shall not be considered CFRS facilities as defined in 3.3.72 where both of the following conditions exist:
  1. The area of the retail sales floor occupied by the retail displays of consumer fireworks does not exceed 25 percent of the area of the retail sales floor in the building or 600 ft2 (55.5 m2), whichever is less;
  2. The consumer fireworks are displayed and sold in a manner approved by the AHJ and comply with the applicable provisions of this code, federal and state law, and local ordinances.

65.10.5.1.2

AMENDMENT
This section has been amended at the state or city level.
Consumer fireworks displayed for sale in stores shall comply with the following:
  1. Such fireworks shall be under the visual supervision of a store employee or other responsible party while the store is open to the public;
  2. Such fireworks shall be packaged fireworks merchandise;
  3. Such fireworks shall be packaged and displayed for sale in a manner that will limit travel distance of ejected pyrotechnical components if ignition of the fireworks occurs;

65.10.5.2 Egress

AMENDMENT
This section has been amended at the state or city level.
Means of egress in stores shall comply with Chapter 14 and NFPA 101, unless otherwise specified in 65.10.3.14.

65.10.5.3 Storage Rooms

AMENDMENT
This section has been amended at the state or city level.
Storage rooms containing consumer fireworks in a new permanent store shall be protected with an automatic sprinkler system installed in accordance with Section 13.3 and NFPA 13 or separated from the retail sales area by a fire barrier having a fire resistance rating of not less than 1 hour.

65.10.5.3.1

AMENDMENT
This section has been amended at the state or city level.
Door and window openings in the fire barrier wall shall be protected by self-closing fire doors or fixed fire windows having a fire protection rating of not less than 1 hour and shall be installed in accordance with Section 12.4 and NFPA 80.

65.10.5.3.2

AMENDMENT
This section has been amended at the state or city level.
Any other openings or penetrations in the fire barrier wall shall be protected in accordance with NFPA 101.

65.10.5.4 Alarm Notification

AMENDMENT
This section has been amended at the state or city level.
In Class B stores, a public address system or a means for manually activating audible and visible alarm indicating devices located throughout the facility in accordance with Section 13.7 and NFPA 72 shall be provided at a constantly attended location when the store is occupied.

65.10.5.5

AMENDMENT
This section has been amended at the state or city level.
Flame breaks shall be allowed to be omitted in stores protected throughout with an automatic sprinkler system installed in accordance with Section 13.3 and NFPA 13.

65.10.6 Stands

AMENDMENT
This section has been amended at the state or city level.

65.10.6.1 Site Plan

AMENDMENT
This section has been amended at the state or city level.
The site plan for stands shall show the location of the stand on the site and indicate the minimum separation distances required by 65.10.4.7.

65.10.6.2 Temporary Stands

AMENDMENT
This section has been amended at the state or city level.

65.10.6.2.1 Portable Fire Extinguisher

AMENDMENT
This section has been amended at the state or city level.
Temporary CFRS stands of less than 200 ft2 (18.6 m2) shall be required to have only one portable fire extinguisher.

65.10.6.2.2 Fire Safety and Evacuation Plan

AMENDMENT
This section has been amended at the state or city level.
An approved fire safety and evacuation plan shall not be required for temporary CFRS stands.

65.10.6.2.3 Means of Egress

AMENDMENT
This section has been amended at the state or city level.

65.10.6.2.3.1

AMENDMENT
This section has been amended at the state or city level.
Retail sales areas within temporary CFRS stands shall have a minimum of two exits.

65.10.6.2.3.2

AMENDMENT
This section has been amended at the state or city level.
Exits provided for temporary fireworks retail sales stands shall be located such that the maximum egress travel distance as measured from the most remote point to an exit along the natural and unobstructed path of egress travel does not exceed 35 ft (10.6 m).

65.10.6.2.3.3

AMENDMENT
This section has been amended at the state or city level.
Customers shall not be permitted inside a temporary CFRS stand unless it complies with the means of egress requirements in 65.10.3.14.

65.10.6.2.3.4

AMENDMENT
This section has been amended at the state or city level.
Exit signs shall not be required to be illuminated in stands that are not open for business after dusk, or in temporary CFRS stands where the interior is not accessible to the public.

65.10.6.2.3.5

AMENDMENT
This section has been amended at the state or city level.
Emergency lighting shall not be required in stands that are not open for business after dusk or for temporary CFRS stands where the interior is not accessible to the public.

65.10.6.3 Minimum Separation Distances

AMENDMENT
This section has been amended at the state or city level.
Temporary CFRS stands shall be separated from adjacent buildings and structures in accordance with Table 65.10.4.7.2.

65.10.6.4 Stands Not Open to the Public

AMENDMENT
This section has been amended at the state or city level.

65.10.6.4.1 Minimum Clear Width of Aisles

AMENDMENT
This section has been amended at the state or city level.
In temporary CFRS stands where the interior is not accessible to the public, the minimum clear width of the aisle shall be permitted to be not less than 28 in. (710 mm).

65.10.6.4.2 Egress Doors

AMENDMENT
This section has been amended at the state or city level.

65.10.6.4.2.1

AMENDMENT
This section has been amended at the state or city level.
Egress doors provided for temporary CFRS stands where the interior is not accessible to the public shall be permitted to be not less than 28 in. (710 mm) in width.

65.10.6.4.2.2

AMENDMENT
This section has been amended at the state or city level.
For temporary CFRS stands where the interior is not accessible to the public, latching devices on doors shall be permitted without panic hardware.

65.10.6.4.3 Storage

AMENDMENT
This section has been amended at the state or city level.
In temporary CFRS stands where the interior is not accessible to the public, the maximum height of sales displays shall be limited to 8 ft (2.44 m).

65.10.6.4.4 Flame Breaks

AMENDMENT
This section has been amended at the state or city level.
Temporary CFRS stands where the interior is not accessible to the public shall not be required to comply with 65.10.3.15.3.

65.10.6.4.5 Covered Fuses

AMENDMENT
This section has been amended at the state or city level.

65.10.6.4.5.1

AMENDMENT
This section has been amended at the state or city level.
Only consumer fireworks meeting the criteria for covered fuses as described in 65.10.3.15.5.2 shall be permitted where the retail sales of consumer fireworks are conducted.

65.10.6.4.6 Sales Display

AMENDMENT
This section has been amended at the state or city level.
The following shall apply to the sales display of consumer fireworks in temporary CFRS stands that do not allow access to the interior of the stand by the public:
  1. Consumer fireworks shall be displayed in a manner that prevents the fireworks from being handled by persons other than those operating, supervising, or working in the temporary CFRS stand.
  2. The handling requirements of 65.10.6.4.6(1) shall not apply to packaged assortments, boxes, or similarly packaged containers of one or more items, regardless of type.