(The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance.)
Wall and floor-ceiling assemblies separating dwelling units, including those separating adjacent townhouse units, shall provide air-borne sound insulation for walls, and both air-borne and impact sound insulation for floor-ceiling assemblies.
Air-borne sound insulation for wall and floor-ceiling assemblies shall meet a sound transmission class (STC) rating of 45 when tested in accordance with ASTM E 90. Penetrations or openings in construction assemblies for piping; electrical devices; recessed cabinets; bathtubs; soffits; or heating, ventilating or exhaust ducts shall be sealed, lined, insulated or otherwise treated to maintain the required ratings. Dwelling unit entrance doors, which share a common space, shall be tight fitting to the frame and sill.
The sound transmission class of concrete masonry and clay masonry assemblies shall be calculated in accordance with TMS 0302 or determined through testing in accordance with ASTM E 90.
Floor/ceiling assemblies between dwelling units, or between a dwelling unit and a public or service area within a structure, shall have an impact insulation class (IIC) rating of not less than 45 when tested in accordance with ASTM E 492.
ASTM
ASTM E 90—04 Test Method for Laboratory
Measurement of Air-borne Sound
Transmission Loss of Building
Partitions and Elements
AK102
ASTM E 492—09 Specification for Laboratory
Measurement of Impact Sound
Transmission through Floor-ceiling
Assemblies Using the Tapping
Machine
AK103
The Masonry Society
TMS 0302—12 Standard for Determining
the Sound Transmission Class Rating
for Masonry Walls
AK102.1.1