Heads up: There are no amended sections in this chapter.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 107.

AAMA American Architectural Manufacturers Association
1827 Walden Office Square Suite 550
Schaumburg, IL 60173-4268
 
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA 101/I.S.2/A c440—05 Specifications for Windows, Doors and Unit Skylights 402.4.4, 502.4.1
     
AHRI Air Conditioning, Heating, and Refrigeration Institute
4100 North Fairfax Drive Suite 200
Arlington, VA 22203
 
Standard
reference
number
Title Referenced
in code
section number
210/240—03 Unitary Air-Conditioning and Air-Source Heat Pump Equipment Table 503.2.3(1), Table 503.2.3(2)
310/380—93 Standard for Packaged Terminal Air-conditioners and Heat Pumps Table 503.2.3(3)
340/360—2000 Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment Table 503.2.3(1), Table 503.2.3(2)
365—02 Commercial and Industrial Unitary Air-conditioning Condensing Units Table 503.2.3(6)
440—05 Room Fan-coil 503.2.8
550/590—98 Water Chilling Packages Using the Vapor Compression Cycle—with Addenda Table 503.2.3(7)
560—00 Absorption Water Chilling and Water Heating Packages Table 503.2.3(7)
840—1998 Unit Ventilators 503.2.8
13256-1 (2004) Water-source Heat Pumps—Testing and Rating for Performance—Part 1: Water-to-air and Brine-to-air Heat Pumps Table 503.2.3(2)
1160—2004 Performance Rating of Heat Pump Pool Heaters Table 504.2
     
AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004-1806
 
Standard
reference
number
Title Referenced
in code
section number
500D—07 Laboratory Methods for Testing Dampers for Rating 502.4.5
     
ANSI American National Standards Institute
25 West 43rd Street Fourth Floor
New York, NY 10036
 
Standard
reference
number
Title Referenced
in code
section number
Z21.10.3—01 Gas Water Heaters, Volume III - Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous—with Addenda Z21.10.3a-2003 and Z21.10.3b-2004 Table 504.2
Z21.13—04 Gas-fired Low Pressure Steam and Hot Water Boilers Table 503.2.3(5)
Z21.47—03 Gas-fired Central Furnaces Table 503.2.3(4)
Z83.8—02 Gas Unit Heaters and Gas-Fired Duct Furnaces—with Addendum Z83.8a-2003 Table 503.2.3(4)
     
ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle,
NE Atlanta, GA 30329-2305
 
Standard
reference
number
Title Referenced
in code
section number
119—88 (RA 2004) Air Leakage Performance for Detached Single-family Residential Buildings Table 405.5.2(1)
140—2007 Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs 506.6.1
146—1998 Testing and Rating Pool Heaters Table 504.2
ANSI/ASHRAE/ACCA Standard 183—2007 Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings 503.2.1
13256-1 (2005) Water-source Heat Pumps—Testing and Rating for Performance—Part 1: Water-to-air and Brine-to-air Heat Pumps (ANSI/ASHRAE/IESNA 90.1-2004) Table 503.2.3(2)
90.1—2007 Energy Standard for Buildings Except Low-rise Residential Buildings (ANSI/ASHRAE/IESNA 90.1-2007) 501.1, 501.2, 502.1.1, Table 502.2(2)
ASHRAE—2005 ASHRAE Handbook of Fundamentals 402.1.4, Table 405.5.2(1)
ASHRAE—2004 ASHRAE HVAC Systems and Equipment Handbook-2004 503.2.1
     
ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title Referenced
in code
section number
PTC 4.1 - 1964 Steam Generating Units Table 503.2.3(5) (Reaffirmed 1991)
     
ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2859
 
Standard
reference
number
Title Referenced
in code
section number
C 90—06b Specification for Load-bearing Concrete Masonry Units Table 502.2(1)
E 283—04 Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen 402.4.5, 502.4.2, 502.4.8
     
CSA Canadian Standards Association
5060 Spectrum Way Mississauga,
Ontario, Canada L4W 5N6
 
Standard
reference
number
Title Referenced
in code
section number
101/I.S.2/A440—08 Specifications for Windows, Doors and Unit Skylights 402.4.4, 502.4.1
     
DOE U.S. Department of Energy c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
 
Standard
reference
number
Title Referenced
in code
section number
10 CFR Part 430, Subpart B, Appendix E (1998) Uniform Test Method for Measuring the Energy Consumption of Water Heaters Table 504.2
10 CFR Part 430, Subpart B, Appendix N (1998) Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers Table 503.2.3(4), Table 503.2.3(5)
10 CFR Part 431, Subpart E 2004 Test Procedures and Efficiency Standards for Commercial Packaged Boilers Table 503.2.3(6)
DOE/EIA—0376 (Current Edition) State Energy Prices and Expenditure Report 405.3, 506.2
     
ICC International Code Council, Inc.
500 New Jersey Avenue, NW 6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
IBC—09 International Building Code® 303.2, 201.3
IFC—09 International Fire Code® 201.3
IFGC—09 International Fuel Gas Code® 201.3
IMC—09 International Mechanical Code® 503.2.5, 503.2.6, 503.2.7.1, 503.2.7.1.1, 503.2.7.1.2, 503.2.9.1, 503.3.1, 503.4.5
IPC—09 International Plumbing Code® 201.3
IRC—09 International Residential Code® 201.3, 403.2.2, 403.6, 405.6.1, Table 405.5.2(1)
     
IESNA Illuminating Engineering Society of North America
120 Wall Street, 17th Floor
New York, NY 10005-4001
 
Standard
reference
number
Title Referenced
in code
section number
90.1-2007 Energy Standard for Buildings Except Low-rise Residential Buildings 501.1, 501.2, 502.1.1, Table 502.2(2)
     
NFRC National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt, MD 20770
 
Standard
reference
number
Title Referenced
in code
section number
100—04 Procedure for Determining Fenestration Product U-factors—Second Edition 303.1.3
200—04 Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence—Second Edition 303.1.3
400—04 Procedure for Determining Fenestration Product Air Leakage—Second Edition 402.4.2, 502.4.1
     
SMACNA Sheet Metal and Air Conditioning Contractors National Association, Inc.
4021 Lafayette Center Drive
Chantilly, VA 20151-1209
 
Standard
reference
number
Title Referenced
in code
section number
SMACNA—85 HVAC Air Duct Leakage Test Manual 503.2.7.1.3
     
UL Underwriters Laboratories Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
 
Standard
reference
number
Title Referenced
in code
section number
727—06 Oil-fired Central Furnaces Table 503.2.3(4)
731—95 Oil-fired Unit Heaters—with Revisions through February 2006 Table 503.2.3(4)
     
US—FTC United States - Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
 
Standard
reference
number
Title Referenced
in code
section number
CFR Title 16 R-value Rule 303.1.4
     
WDMA Window and Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
 
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA 101/I.S.2/A440—08 Specifications for Windows, Doors and Unit Skylights 402.4.4, 502.4.1
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING