Chapter 44 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.
CALIFORNIA RESIDENTIAL CODE — MATRIX ADOPTION TABLE CHAPTER 44 — REFERENCED STANDARDS
(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
Adopting agency BSC BSC-CG SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
1 2 1/AC AC SS SS/
CC
1 1R 2 3 4 5
Adopt entire chapter                                              
Adopt entire chapter as amended (amended sections listed below)     X X                                      
Adopt only those sections that are listed below     X                                        
Chapter / Section                                              
ANSI     X                                        
ASTM     X X                                      
ICC     X                                        
IFC-18       X                                      
NFPA     X                                        
SFM     X                                        
UBC     X                                        


Notwithstanding California laws and regulations, these referenced standards shall be applicable only to those California Residential Code sections that are adopted.


User note:
About this chapter: The one- and two-family dwelling code contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials, products and methods of construction. Chapter 44 contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.






AAMA American Architectural Manufacturers Association
1827 Walden Office Square, Suite 550
Schaumburg, IL 60173
AAMA/WDMA/CSA 101/I.S.2/A440—17 North American Fenestration Standards/Specifications for Windows, Doors and Skylights R308.6.9, R609.3
450—10 Voluntary Performance Rating Method for Mulled Fenestration Assemblies R609.8
506—16 Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration Products R609.6.1
711—13 Voluntary Specification for Self-adhering Flashing Used for Installation of Exterior Wall Fenestration Products R703.4
712—14 Voluntary Specification for Mechanically Attached Flexible Flashing R703.4
714—15 Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive Seal around Exterior Wall Openings in Buildings R703.4
AAMA/NPEA/NSA 2100—12 Specifications for Sunrooms R301.2.1.1.1
     
ACCA   Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Manual D—2016 Residential Duct Systems Table R301.2(1)
     
ACI   American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
318—14 Building Code Requirements for Structural Concrete R301.2.2.2.5, R402.2, Table R404.1.2(2), Table R404.1.2(5), Table R404.1.2(6), Table R404.1.2(7)Table R404.1.2(8), R404.1.3, R404.1.3.1, R404.1.3.3, R404.1.3.4, R404.1.4.2, R404.5.1, R608.1R608.1.1, R608.1.2, R608.2, R608.5.1, R608.6.1, R608.8.2, R608.9.2, R608.9.3
332—14 Residential Code Requirements for Structural Concrete R402.2, R403.1, R404.1.3, R404.1.3.4, R404.1.4.2, R506.1
     
AISI   American Iron and Steel Institute
25 Massachusetts Avenue, NW Suite 800
Washington, DC 20001
AISI S100—16 North American Specification for the Design of Cold-formed Steel Structural Members, 2016 R608.9.2, R608.9.3
AISI S220—15 North American Standard for Cold-formed Steel Framing—Nonstructural Members, 2015 R702.3.3
AISI S230—15 Standard for Cold-formed Steel Framing—Prescriptive Method for One- and Two-family Dwellings, 2015 R301.1.1, R301.2.1.1, R301.2.2.7, R301.2.2.8, R603.6, R603.9.4.1, R603.9.4.2, R608.9.2, R608.9.3, Figure 608.9(11), R608.10
AISI S240—15 North American Standard for Cold-Formed Steel Structural Framing R505.1.3, R603.6, R702.3.3, R804.3.6
     
ANSI   American National Standards Institute
25 West 43rd Street, 4th Floor
New York, NY 10036
A108.1A—16 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar R702.4.1
A108.1B—99 Installation of Ceramic Tile, Quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar R702.4.1
A108.4—99 Installation of Ceramic Tile with Organic Adhesives or Water-Cleanable Tile-setting Epoxy Adhesive R702.4.1
A108.5—99 Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex Portland Cement Mortar R702.4.1
A108.6—99 Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy R702.4.1
A108.11—99 Interior Installation of Cementitious Backer Units R702.4.1
ANSI 117—2015 Standard Specifications for Structural Glued Laminated Timber of Softwood Species R502.1.3, R602.1.3, R802.1.3
A118.1—16 American National Standard Specifications for Dry-set Portland Cement Mortar R702.4.1
A118.3—13 American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy, and Water-cleanable Tile-setting Epoxy Adhesive R702.4.1
A118.4—16 American National Standard Specifications for Modified Dry-Set Cement Mortar R606.2.11
A136.1—08 American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile R702.4.1
A137.1—17 American National Standard Specifications for Ceramic Tile R702.4.1
S3.41 American National Standard Audible Evacuation Signal R335.5.2.1
Z97.1—2014 Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test R308.1.1, R308.3.1
     
APA   APA—The Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
ANSI/A190.1—2017 Structural Glued-laminated Timber R502.1.3, R602.1.3, R802.1.2
ANSI/APA PRP 210—2014 Standard for Performance-rated Engineered Wood Siding R604.1, Table R703.3(1), R703.3.4
ANSI/APA PRG 320—2017 Standard for Performance-rated Cross Laminated Timber R502.1.6, R602.1.6, R802.1.6
ANSI/APA PRR 410—2016 Standard for Performance-rated Engineered Wood Rim Boards R502.1.7, R602.1.7, R802.1.7
ANSI/APA PRS 610.1—2013 Standard for Performance-Rated Structural Insulated Panels in Wall Applications R602.1.11, R610.3, R610.4
APA E30—15 Engineered Wood Construction Guide Table R503.2.1.1(1), R503.2.2, R803.2.2, R803.2.3
     
ASCE/SEI   American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
7—16 Minimum Design Loads and Associated Criteria for Buildings and Other Structures R301.2.1.1, R301.2.1.2, R301.2.1.2.1, R301.2.1.5, R301.2.1.5.1, Table R608.6(1), Table R608.6(2)Table R608.6(3), Table R608.6(4), Table R608.7(1A), Table R608.7(1B), Table R608.7(1C)R608.9.2, R608.9.3, R609.2, R609.6.2
24—14 Flood-resistant Design and Construction R301.2.4, R301.2.4.1, R322.1, R322.1.1, R322.1.6, R322.1.9, R322.2.2, R322.3.3
32—01 Design and Construction of Frost-protected Shallow Foundations R403.1.4.1
     
ASSE   ASSE International
18927 Hickory Creek Drive, Suite 220
Mokena, IL 60448
1051—2009 Performance Requirements for Individual and Branch-type Air Admittance Valves for Plumbing Drainage Systems  
     
ASTM   ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken, PA 19428
A36/A36M—14 Specification for Carbon Structural Steel R608.5.2.2
A53/A53M—12 Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless R407.3
A123/A123M—15 Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products Table 507.2.3
A153/A153M—09 Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware R317.3, Table 507.2.3, Table R606.3.4.1, R703.6.3, R905.7.5, R905.8.6
A167—99(2009) Specification for Stainless and Heat-resisting Chromium-nickel Steel Plate, Sheet and Strip Table R606.3.4.1
A240/A240M—15A Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications Table R905.10.3(1)
A307—14 Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength R608.5.2.2, Table R507.2.3
A463/A463M—15 Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip Process Table R905.10.3(2)
A563—15 Standard Specification for Carbon and Alloy Steel Nuts Table R507.2.3
A615/A615M—2015aE1 Specification for Deformed and Plain Carbon-steel Bars for Concrete Reinforcement R402.3.1, R403.1.3.5.1, R404.1.3.3.7.1, R608.5.2.1
A641/A641M—09a(2014) Specification for Zinc-coated (Galvanized) Carbon Steel Wire Table R606.3.4.1
A653/A653M—15 Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron Alloy-coated (Galvannealed) by the Hot-dip Process R317.3.1, R505.2.2, Table R507.2.3, R603.2.2, Table R606.3.4.1, R608.5.2.3, R804.2.2, R804.2.3Table R905.10.3(1), Table R905.10.3(2)
A706/A706M—15 Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement R402.3.1, R403.1.3.5.1, R404.1.3.3.7.1, R608.5.2.1
A755/A755M—2015 Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products Table R905.10.3(2)
A792/A792M—10(2015) Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process R505.2.2, R603.2.2, R608.5.2.3, R804.2.2, Table 905.10.3(2)
A875/A875M—13 Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip Process R608.5.2.3, Table R905.10.3(2)
A924/A924M—14 Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process Table R905.10.3(1)
A996/A996M—15 Specifications for Rail-steel and Axle-steel Deformed Bars for Concrete Reinforcement R403.1.3.5.1, Table R404.1.2(9), R404.1.3.3.7.1, R608.5.2.1, Table R608.5.4(2)
A1003/A1003M—15 Standard Specification for Steel Sheet, Carbon, Metallic and Nonmetallic-coated for Cold-formed Framing Members R505.2.1, R505.2.2, R603.2.1, R603.2.2, R804.2.1, R804.2.2
B101—12 Specification for Lead-coated Copper Sheet and Strip for Building Construction Table R905.2.8.2, Table R905.10.3(1)
B209—14 Specification for Aluminum and Aluminum-alloy Sheet and Plate Table 905.10.3(1)
B370—12 Specification for Copper Sheet and Strip for Building Construction Table R905.2.8.2, Table R905.10.3(1)
B695—04(2009) Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel R317.3.1, R317.3.3
C5—10 Specification for Quicklime for Structural Purposes R702.2.1
C22/C22M—2015 Specification for Gypsum R702.2.1, R702.3.1
C27—98(2013) Specification for Standard Classification of Fireclay and High-alumina Refractory Brick R1001.5
C28/C28M—10(2015) Specification for Gypsum Plasters R702.2.1
C33/C33M—13 Specification for Concrete Aggregates R403.4.1
C34—13 Specification for Structural Clay Load-bearing Wall Tile Table R301.2(1), R606.2.2
C35/C35M—(2014) Specification for Inorganic Aggregates for Use in Gypsum Plaster R702.2.1
C55—2014A Specification for Concrete Building Brick R202, Table R301.2(1), R606.2.1
C56—13 Standard Specification for Structural Clay Nonloadbearing Tile R606.2.2
C59/C59M—00(2015) Specification for Gypsum Casting Plaster and Molding Plaster R702.2.1
C61/C61M—00(2015) Specification for Gypsum Keene's Cement R702.2.1
C62—13A Standard Specification for Building Brick (Solid Masonry Units Made from Clay or Shale) R202, Table R301.2(1), R606.2.2
C73—14 Specification for Calcium Silicate Face Brick (Sand Lime Brick) R202, Table R301.2(1), R606.2.1
C90—14 Specification for Load-bearing Concrete Masonry Units Table R301.2(1), 606.2.1
C91/C91M—12 Specification for Masonry Cement R702.2.2, R703.7.2
C94/C94M—15A Standard Specification for Ready-mixed Concrete R404.1.3.3.2, R608.5.1.2
C126—15 Standard Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units R606.2.2
C129—14A Specification for Nonload-bearing Concrete Masonry Units Table R301.2(1)
C143/C143M—15 Test Method for Slump of Hydraulic Cement Concrete R404.1.3.3.4, R608.5.1.4
C145—85 Specification for Solid Load-bearing Concrete Masonry Units R202, Table R301.2(1)
C150/C150M—15 Specification for Portland Cement R608.5.1.1, R702.7.2
C199—84(2011) Test Method for Pier Test for Refractory Mortar R1001.5, R1001.8, R1003.12
C203—05a(2012) Standard Test Methods for Breaking Load and Flexural Properties of Block-type Thermal Insulation  
C207—06(2011) Specification for Hydrated Lime for Masonry Purposes Table R606.2.8
C208—12 Specification for Cellulosic Fiber Insulating Board R602.1.10, Table R602.3(1), Table R906.2
C212—14 Standard Specification for Structural Clay Facing Tile  
C216—15 Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) R202, Table R301.2(1), R606.2.2
C270—14A Specification for Mortar for Unit Masonry R606.2.8, Table R606.2.8, R606.2.11
C315—07(2011) Specification for Clay Flue Liners and Chimney Pots R1001.8, R1003.11.1, Table 1003.14(1)
C406/C406M—2015 Specifications for Roofing Slate R905.6.4
C475/C475M—15 Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard R702.3.1
C476—10 Specification for Grout for Masonry R606.2.12
C503/C503M—2010 Standard Specification for Marble Dimension Stone R606.2.4
C514—04(2014) Specification for Nails for the Application of Gypsum Wallboard R702.3.1
C552—15 Standard Specification for Cellular Glass Thermal Insulation Table R906.2
C557—03(2009)e01 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing R702.3.1.1
C568/C568M—2010 Standard Specification for Limestone Dimension Stone R606.2.4
C578—15 Specification for Rigid, Cellular Polystyrene Thermal Insulation R316.8, R403.3, Table 703.8.4(2), Table R703.15.1, Table R703.15.2, Table R703.16.1Table R703.16.2, Table R906.2
C587—04(2014) Specification for Gypsum Veneer Plaster R702.2.1
C595/C595M—14E1 Specification for Blended Hydraulic Cements R608.5.1.1, R702.2.2, R703.7.2
C615/C615M—11 Standard Specification for Granite Dimension Stone R606.2.4
C616/C616M—10 Standard Specification for Quartz-based Dimension Stone R606.2.4
C629/C629M—10 Standard Specification for Slate Dimension Stone R606.2.4
C631—09(2014) Specification for Bonding Compounds for Interior Gypsum Plastering R702.2.1
C645—14 Specification for Nonstructural Steel Framing Members R702.3.3
C652—15 Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale) R202, Table R301.2(1), R606.2.2
C685/C685M—14 Specification for Concrete Made by Volumetric Batching and Continuous Mixing R404.1.3.3.2, R608.5.1.2
C726—12 Standard Specification for Mineral Wool Roof Insulation Board Table R906.2
C728—15 Standard Specification for Perlite Thermal Insulation Board Table R906.2
C744—14 Standard Specification for Prefaced Concrete and Calcium Silicate Masonry Units R606.2.1
C836/C836M—15 Specification for High Solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course R905.15.2
C841—03(2013) Standard Specification for Installation of Interior Lathing and Furring R702.2.1
C842—05(2015) Standard Specification for Application of Interior Gypsum Plaster R702.2.1
C843—99(2012) Specification for Application of Gypsum Veneer Plaster R702.2.1
C844—2015 Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster R702.2.1
C847—14A Specification for Metal Lath R702.2.1, R702.2.2
C887—13 Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar R406.1, R606.2.9
C897—15: Specification for Aggregate for Job-mixed Portland Cement-based Plasters R702.2.2
C920—14A Standard Specification for Elastomeric Joint Sealants R406.4.1
C926—15B Specification for Application of Portland Cement-based Plaster R702.2.2, R702.2.2.1, R703.7, R703.7.2, R703.7.2.1, R703.7.4
C933—14 Specification for Welded Wire Lath R702.2.1, R702.2.2
C946—10 Standard Practice for Construction of Dry-Stacked, Surface-Bonded Walls R606.2.9
C954—15 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or to 0.112 in. (2.84 mm) in Thickness R505.2.5, R603.2.5, R702.3.5.1, R804.2.5
C957/C957M—15 Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Integral Wearing Surface R905.15.2
C1002—14 Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs R702.3.1, R702.3.5.1
C1029—15 Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation R905.14.2
C1032—14 Specification for Woven Wire Plaster Base R702.2.1, R702.2.2
C1047—14a Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base R702.2.1, R702.2.2, R702.3.1
C1063—15A Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster R702.2.2, R703.7, R703.7.1
C1088—14 Standard Specification for Thin Veneer Brick Units Made from Clay or Shale R606.2.2
C1107/C1107M—14A Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink) R402.3.1
C1116/C116M—10(2015) Standard Specification for Fiber-reinforced Concrete and Shotcrete R402.3.1
C1157—11/C1157M—11 Standard Performance Specification for Hydraulic Cement R608.5.1.1, R703.7.2
C1167—11 Specification for Clay Roof Tiles R905.3.4
C1177/C1177M—13 Specification for Glass Mat Gypsum Substrate for Use as Sheathing R702.3.1, Table 906.2
C1178/C1178M—13 Specification for Glass Mat Water-resistant Gypsum Backing Panel R702.3.1, R702.3.7, Table R702.4.2
C1186—08(2012) Specification for Flat Fiber Cement Sheets R703.10.1, R703.10.2
C1261—13 Specification for Firebox Brick for Residential Fireplaces R1001.5, R1001.8
C1278/C1278M—07a(2011) Specification for Fiber-reinforced Gypsum Panels R702.3.1, R702.3.7, Table R702.4.2, Table R906.2
C1283—11 Practice for Installing Clay Flue Lining R1003.9.1, R1003.12
C1288—14 Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets Table R503.2.1.1(1), Table R503.2.1.1(2), Table 602.3(2), Table R702.4.2
C1289—15 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board R316.8, Table R703.15.1, Table R703.15.2, Table R703.16.1, Table R703.16.2, Table R906.2
C1325—14 Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate Sheets Backer Units Table R702.4.2
C1328/C1328M—12 Specification for Plastic (Stucco) Cement R702.2.2, R703.7.2
C1364—10B Standard Specification for Architectural Cast Stone R606.2.5
C1396/C1396M—2014A Specification for Gypsum Board Table R602.3(1), R702.2.1, R702.2.2, R702.3.1, R702.3.7
C1405—15 Standard Specification for Glazed Brick (Single Fired, Brick Units) R606.2.2
C1492—03(2009) Specification for Concrete Roof Tile R905.3.5
C1513—201 Standard Specification for Steel Tapping Screws for Cold-formed Steel Framing Connections R505.2.5, R603.2.5, R702.3.5.1, Table R703.3(2), Table R703.16.1, Table R703.16.2, R804.2.5
C1634—15 Standard Specification for Concrete Facing Brick R606.2.1
C1658/C1658M—13 Standard Specification for Glass Mat Gypsum Panels R702.3.1
C1670/1670M—16 Standard Specification for Adhered Manufactured Stone Masonry Veneer Units R606.2.6
C1691—11 Standard Specification for Unreinforced Autoclaved Aerated Concrete (AAC) Masonry Units R606.2.3
C1693—11 Standard Specification for Autoclaved Aerated Concrete (AAC) R606.2.3
C1766—13 Standard Specification for Factory-Laminated Gypsum Panel Products R702.3.1
D41/D41M—2011 Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing Table R905.9.2, Table R905.11.2
D43/D43M—2000(2012)E1 Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing Table R905.9.2
D226/D226M—09 Specification for Asphalt-saturated (Organic Felt) Used in Roofing and Waterproofing R703.2, R905.1.1, Table R905.1.1(1), R905.8.4, Table R905.9.2
D227/D227M—03(2011)e1 Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing Table R905.9.2
D312/D321M—15 Specification for Asphalt Used in Roofing Table R905.9.2
D422—63(2007)E2 Test Method for Particle-size Analysis of Soils R403.1.8.1
D449/D449M—03(2014)E1 Specification for Asphalt Used in Dampproofing and Waterproofing R406.2
D450/D450M—07(2013)E1 Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing Table R905.9.2
D1227—13 Specification for Emulsified Asphalt Used as a Protective Coating for Roofing Table R905.9.2, Table R905.11.2, R905.15.2
D1863/D1863M—05(2011)e1 Specification for Mineral Aggregate Used in Built-up Roofs Table R905.9.2
D1970/D1970M—2015A Specification for Self-adhering Polymer Modified Bitumen Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection R905.1.1, R905.2.8.2, R905.11.2.1
D2178/D2178M—15 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table R905.9.2
D2626/D2626M—04 (2012)e1 Specification for Asphalt-saturated and Coated Organic Felt Base Sheet Used in Roofing Table R905.1.1(1), Table R905.9.2
D2822/D2822M—05(2011)e1 Specification for Asphalt Roof Cement, Asbestos Containing Table R905.9.2
D2823/D2823M—05(2011)e1 Specification for Asphalt Roof Coatings, Asbestos Containing Table R905.9.2
D2824/D2824M—2013 Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered and Fibered without Asbestos Table R905.9.2, Table R905.11.2
D2898—10 Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing R802.1.5.4, R802.1.5.8
D3019—08 Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered Table R905.9.2, Table R905.11.2
D3161/D3161M—15 Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan Induced Method) R905.2.4.1, Table R905.2.4.1, R905.16.6
D3201/D3201M—2013 Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base Products R802.1.5.9
D3462/D3462M—10A Specification for Asphalt Shingles Made From Glass Felt and Surfaced with Mineral Granules R905.2.4
D3468/D3468M—99(2013)E1 Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene Used in Roofing and Waterproofing R905.15.2
D3679—13 Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding R703.11
D3737—2012 Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam) R502.1.3, R602.1.3, R802.1.2
D3747—79(2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table R905.9.2, Table R905.11.2
D3909/D3909M—14 Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules R905.2.8.2, R905.5.4, Table R905.9.2
D4022/D4022M—2007(2012)e1 Specification for Coal Tar Roof Cement, Asbestos Containing Table R905.9.2
D4318—10E1 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils R403.1.8.1
D4434/D4434M—12 Specification for Poly (Vinyl Chloride) Sheet Roofing R905.13.2
D4479/D4479M—07(2012)e1 Specification for Asphalt Roof Coatings—asbestos-free Table R905.9.2
D4586/D4586M—07(2012)e1 Specification for Asphalt Roof Cemen—asbestos-free Table R905.9.2
D4601/D4601M—04(2012)e1 Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table R905.9.2, R905.11.2.1
D4637/D4637M—14E1 Specification for EPDM Sheet Used in Single-ply Roof Membrane R905.12.2
D4829—11 Test Method for Expansion Index of Soils R403.1.8.1
D4869/D4869M—15 Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing R905.1.1, Table R905.1.1(1)
D4897/D4897M—01(2009) Specification for Asphalt Coated Glass-fiber Venting Base Sheet Used in Roofing Table R905.9.2
D4990—1997a(2013) Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table R905.9.2
D5019—07a Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane R905.12.2
D5055—13E1 Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists R502.1.2, R802.1.8
D5456—14B Standard Specification for Evaluation of Structural Composite Lumber Products R502.1.5, R602.1.5, R802.1.4
D5516—09 Test Method for Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures R802.1.5.6
D5643/D5643M—06(2012)e1 Specification for Coal Tar Roof Cement Asbestos-free Table R905.9.2
D5664—10 Test Methods For Evaluating the Effects of Fire-retardant Treatments and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber R802.1.5.7
D5665/D5665M—99a(2014)E1 Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing Table R905.9.2
D5726—98(2013) Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing Table R905.9.2
D6083—05e01 Specification for Liquid-applied Acrylic Coating Used in Roofing Table R905.9.2, Table R905.11.2, Table R905.14.3, R905.15.2
D6162/D6162M—2000a(2015)E1 Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements Table R905.11.2
D6163/D6163M—2000(2015)E1 Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements Table R905.11.2
D6164/D6164M—11 Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements Table R905.11.2
D6222/D6222M—11 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements Table R905.11.2
D6223/D6223M—02(2009)E1 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcement Table R905.11.2
D6298—13 Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface Table R905.11.2
D6305—08(2015)E1 Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing R802.1.5.6
D6380/D6380—03(2013)E1 Standard Specification for Asphalt Roll Roofing (Organic Felt) Table R905.1.1(1), R905.2.8.2, R905.5.4
D6464—03a(2009)e1 Standard Specification for Expandable Foam Adhesives for Fastening Gypsum Wallboard to Wood Framing R702.3.1.1
D6694/D6694M—08(2013)E1 Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems Table R905.14.3, R905.15.2
D6754/D6754M—10 Standard Specification for Ketone-ethylene-ester-based Sheet Roofing R905.13.2
D6757—2013 Specification for Underlayment Felt Containing Inorganic Fibers Used with Steep Slope Roofing Table R905.1.1(1), R905.1.1
D6841—08 Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber R802.1.5.7
D6878/D6878M—13 Standard Specification for Thermoplastic-polyolefin-based Sheet Roofing R905.13.2
D6947/D6947M—07(2013)E1 Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System Table R905.14.3, R905.15.2
D7032—14 Standard Specification for Establishing Performance Ratings for Wood-plastic Composite Deck Boards and Guardrail Systems (Guards or Handrails) R507.2.2, R507.2.2.1, 507.2.2.3, 507.2.2.4
D7158—D7158M—2016 Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method) R905.2.4.1, Table R905.2.4.1
D7254—15 Standard Specification for Polypropylene (PP) siding Table R703.3(1), R703.14
D7425/D7425M—13 Standard Specification for Spray Polyurethane Foam Used for Roofing Application R905.14.2
D7672—14 Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies R502.1.7, R602.1.7, R802.1.7
D7793—13 Standard Specification for Insulated Vinyl Siding R703.13, Table R703.3(1)
E84—2016 Standard Test Method for Surface Burning Characteristics of Building Materials R202, R302.9.3, R302.9.4, R302.10.1, R302.10.2, R316.3, R316.5.9, R316.5.11, R507.2.2.2R703.14.3, R802.1.5
E96/E96M—2015 Test Method for Water Vapor Transmission of Materials R202, Table R806.5
E108—2016 Test Methods for Fire Tests of Roof Coverings R302.2.4, R902.1
E119—2016 Test Methods for Fire Tests of Building Construction and Materials Table R302.1(1), Table R302.1(2), R302.2.1, R302.2.2, R302.3, R302.4.1, R302.11.1, R606.2.2
E136—2016 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C R202, R302.11
E283—04(2012) Test Method for Determining the Rate of Air Leakage through Exterior Windows, Curtain Walls and Doors under Specified Pressure Differences Across the Specimen R202
E330/E330M—14 Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference R609.4, R609.5, R609.6.2, R703.1.2
E331—00(2009) Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference R703.1.1
E814—2013A Standard Test Method for Fire Tests of Penetration Firestop Systems R302.4.1.2
E970—14 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source R302.10.5
E1602—03(2010)e1 Guide for Construction of Solid Fuel Burning Masonry Heaters R1002.2
E1886—13A Test Method for Performance Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials R301.2.1.2, R609.6.1, R609.6.2, Table R703.11.2
E1996—2014a Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes R301.2.1.2, R301.2.1.2.1, R609.6.1, R609.6.2
E2178—2013 Standard Test Method for Air Permeance of Building Materials R202
E2273—03(2011) Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies R703.9.2
E2568—09e1 Standard Specification for PB Exterior Insulation and Finish Systems R703.9.1, R703.9.2
E2570/E2570M—07(2014)E1 Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage R703.9.2
E2632/E2632M—2013e1 Standard Test Method for Evaluating the Under-Deck Fire Test Response of Deck Materials: R337.9.3, R337.9.4, R337.9.4.1, R337.9.5
E2634—11(2015) Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems R404.1.3.3.6.1, R608.4.4
E2707—2015 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure R337.7.3, R337.7.3.1, R337.8.3
E2726/E2726M—2012a Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands R337.9.3, R337.9.4, R337.9.4.2
E2886/E2886M—2014 Standard Test Method for Evaluating the Ability of Exterior Vents to Resist the Entry of Embers and Direct Flame Impingent R337.6.2, R337.6.3
  *ASTM E2886, Amended Sections as follows:

Revise Sections 10.1.8.3, 10.1.8.4, and 10.1.8.5 as follows:

10.1.8.3 Report the temperatures of the unexposed temperatures on the unexposed side of the vent during the entire optional Insulation Test of the Flame Intrusion.

10.1.8.4 The maximum temperature reached during the test by any one of the unexposed surface thermocouples during the entire optional Insulation Test of the Flame Intrusion Test.

10.1.8.5 The maximum average temperature reached during the test by all of the unexposed surface thermocouples during the entire optional Insulation Test of the Flame Intrusion Test.
 
E2957—2015 Standard Test Method for Resistance to Wildfire Penetration of Eaves, Soffits and Other Projections R337.7.5, R337.7.6, R337.7.8, R337.7.10
  *ASTM E2957, Amended Sections as follows:

Add new Section 12.5 as follows:

12.5 Conditions of Acceptance: Should one of the three replicates fail to meet the Conditions of Acceptance, three additional tests may be run. All of the additional tests must meet the Conditions of Acceptance.
  1. Absence of flame penetration of the eaves or horizontal projection assembly at any time.
  2. Absence of structural failure of the eaves or horizontal projection subassembly at any time.
  3. Absence of sustained combustion of any kind at the conclusion of the 40-minute test.
 
F844—07a(2013) Standard Specification for Washers, Steel, Plain (Flat), Unhardened for General Use Table R507.2.3
F1554—15 Specification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield Strength R608.5.2.2
F1667—15 Specification for Driven Fasteners, Nails, Spikes and Staples R317.3, Table R507.2.3, Table R602.3(1), R703.3.3, R703.6.3, Table R703.15.1, Table R703.15.2R905.2.5
F2090—17 Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms R310.1.1, R312.2.1, R312.2.2
     
AWC   American Wood Council
222 Catocin Circle, Suite 201
Leesburg, VA 20175
AWC STJR—2015 Span Tables for Joists and Rafters R502.3, R802.4, R802.5
AWC WFCM—2015 Wood Frame Construction Manual for One- and Two-family Dwellings R301.1.1, R301.2.1.1, R602.10.8.2, R608.9.2, Figure R608.9(9), R608.10
ANSI AWC NDS—2015 National Design Specification (NDS) for Wood Construction—with 2015 NDS Supplement R404.2.2, R502.2, Table R503.1, R602.3, R608.9.2, Table R703.15.1, Table R703.15.2, R802.2
ANSI AWC PWF—2015 Permanent Wood Foundation Design Specification R317.3.2, R401.1, R404.2.3
     
AWPA   American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
C1—03 All Timber Products—Preservative Treatment by Pressure Processes R902.2
M4—11 Standard for the Care of Preservative-treated Wood Products R317.1.1, R318.1.2
U1—14 USE CATEGORY SYSTEM: User Specification for Treated Wood Except Section 6 Commodity Specification H R317.1, R402.1.2, R504.3, R703.6.3, R905.7.5, Table R905.8.5, R905.8.6
     
CEN   European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
EN 15250-2007 Slow Heat Release Appliances Fired by Solid Fuel Requirements and Test Methods R1002.2
     
CPA   Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
ANSI A135.4—2012 Basic Hardboard Table R602.3(2)
ANSI A135.5—2012 Prefinished Hardboard Paneling R702.5
ANSI A135.6—2012 Engineered Wood Siding R703.5
ANSI A135.7—2012 Engineered Wood Trim R703.5
A208.1—2016 Particleboard R503.3.1, R602.1.9, R605.1
     
CPSC   Consumer Product Safety Commission
4330 East-West Highway
Bethesda, MD 20814
16 CFR, Part 1201—(2002) Safety Standard for Architectural Glazing R308.1.1, R308.3.1, Table R308.3.1(1)
16 CFR, Part 1209—(2002) Interim Safety Standard for Cellulose Insulation R302.10.3
16 CFR, Part 1404—(2002) Cellulose Insulation R302.10.3
     
CSA   CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516
AAMA/WDMA/CSA 101/I.S.2/A440—17 North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights R308.6.9, R609.3
ASME A17.1/CSA B44—2016 Safety Code for Elevators and Escalators R321.1
B44—2013 Safety Code for Elevators and Escalators R321.1
CSA O325—07 Construction Sheathing R503.2.1, R602.1.8, R604.1, R803.2.1
O437-Series—93 Standards on OSB and Waferboard (Reaffirmed 2006) R503.2.1, R602.1.8, R604.1, R803.2.1
     
CSSB   Cedar Shake & Shingle Bureau
P.O. Box 1178
Sumas, WA 98295-1178
CSSB—97 Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau R702.6, R703.6
     
DASMA Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
108—2017 Standard Method for Testing Garage Doors, Rolling Doors and Flexible Doors; Determination of Structural Performance Under Uniform Static/Air Pressure Difference R609.4
115—2016 Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure R301.2.1.2
     
DOC   United States Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230
PS 1—09 Structural Plywood R404.2.1, Table R404.2.3, R503.2.1, R602.1.8, R604.1, R803.2.1
PS 2—10 Performance Standard for Wood-based Structural-use Panels R404.2.1, Table R404.2.3, R503.2.1, R602.1.8, R604.1, R803.2.1
PS 20—05 American Softwood Lumber Standard R404.2.1, R502.1.1, R602.1.1, R802.1.1
     
FEMA   Federal Emergency Management Agency
500 C Street SW
Washington, DC 20472
FEMA TB-2—08 Flood Damage-resistant Materials Requirements R322.1.8
FEMA TB-11—01 Crawlspace Construction for Buildings Located in Special Flood Hazard Area R408.7
     
FM   FM Approvals
Headquarters Office
1151 Boston-Providence Turnpike
P.O. Box 9102
Norwood, MA 02062
4450—(1989) Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992 R906.1
4880—(2015) Approval Standard for Class 1 Rating of Building Panels or Interior Finish Materials R316.6
     
GA   Gypsum Association
6525 Belcrest Road, Suite 480
Hyattsville, MD 20782
GA-253—2016 Application of Gypsum Sheathing Table R602.3(1)
     
HPVA   Hardwood Plywood & Veneer Association
1825 Michael Faraday Drive
Reston, Virginia 20190
ANSI/HPVA HP-1—2016 American National Standard for Hardwood and Decorative Plywood R702.5
     
ICC   International Code Council, Inc.
500 New Jersey Avenue NW
6th Floor
Washington, DC 20001
ICC/ANSI A117.1—09 Accessible and Usable Buildings and Facilities R321.3
ICC—ES EG107 Evaluation guideline for determination of Volatile Organic Compound (voc) content R902
ICC 400—17 Standard on the Design and Construction of Log Structures R301.1.1, R502.1.4, R602.1.4, R703.1, R802.1.3
ICC 500—14 ICC/NSSA Standard on the Design and Construction of Storm Shelters R323.1
ICC 600—14 Standard for Residential Construction in High-wind Regions R301.2.1.1
IEBC—18 International Existing Building Code® R110.2
IFC—18 International Fire Code® R102.7, R324.2
     
ISO International Organization for Standardization
Chemin de Blandonnet 8
CP 401
1214 Vernier
Geneva, Switzerland
8336—2009 Fibre-cement Flat Sheets-product Specification and Test Methods Table R503.2.1.1(1), Table R503.2.1.1(2), Table R602.3(2), Table R702.4.2, R703.10.1, R703.10.2
     
NFPA   National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
13—16 Standard for Installation of Sprinkler Systems as amended* R302.3
  See CCR, Title 24 Part 2 California Building Code, Chapter 35 or CCR, Title 24, Part 9 California Fire Code, Chapter 80 for amendments to NFPA 13.  
13D—16 Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes as amended* R313.1.1, R313.2.1, R324.6.2.1
  *NFPA 13D, Amended Sections as follows:

Revise Section 6.2.2 to read as follows:

6.2.2 Where a well, pump, tank or combination thereof is the source of supply for a fire sprinkler system, the configuration for the system shall be one of the following:
  1. The water supply shall serve both domestic and fire sprinkler systems,
    1. A test connection shall be provided downstream of the pump that creates a flow of water equal to the smallest sprinkler on the system. The connection shall return water to the tank.
    2. Any disconnecting means for the pump shall be approved.
    3. A method for refilling the tank shall be piped to the tank.
    4. A method of seeing the water level in the tank shall be provided without having to open the tank.
    5. The pump shall not be permitted to sit directly on the floor.
  2. A stand-alone tank is permitted if the following conditions are met:
    1. The pump shall be connected to a 220-volt circuit breaker shared with a common household appliance (e.g., range, oven, dryer),
    2. The pump shall be a stainless steel 240-volt pump,
    3. A valve shall be provided to exercise the pump. The discharge of the exercise valve shall drain to the tank, and
    4. A sign shall be provided stating "Valve must be opened monthly for 5 minutes."
    5. A means for automatically refilling the tank level, so that the tank capacity will meet the required water supply duration in minutes, shall be provided.
    6. A test connection shall be provided downstream of the pump that creates a flow of water equal to the smallest sprinkler on the system. The connection may return water to the tank.
    7. Any disconnecting means for the pump shall be approved.
    8. A method for refilling the tank shall be piped to the tank.
    9. A method of seeing the water level in the tank shall be provided without having to open the tank.
    10. The pump shall not be permitted to sit directly on the floor.
Add new Section 6.2.2.1 to read as follows:

6.2.2.1 Where a fire sprinkler system is supplied by a stored water source with an automatically operated means of pressurizing the system other than an electric pump, the water supply may serve the sprinkler system only.

Add new Section 6.2.4 to read as follows:

6.2.4 Where a water supply serves both domestic and fire sprinkler systems, 5 gpm (19 L/min) shall be added to the sprinkler system demand at the point where the systems are connected, to determine the size of common piping and the size of the total water supply requirements where no provision is made to prevent flow into the domestic water system upon operation of a sprinkler. For multipurpose piping systems, the 5 gpm (19 L/min) demand shall be added at the domestic connection nearest the design area. This demand may be split between two domestic connections at 2.5 gpm (10 L/min) each.

Revise Section 8.3.4 to read as follows:

8.3.4* Sprinklers shall not be required in detached garages, open attached porches, carports with no habitable space above, and similar structures.

Revise Section 8.3.4 to read as follows:

8.3.4* Sprinklers shall not be required in detached garages, open attached porches, carports with no habitable space above, and similar structures.

Add new Section 8.3.10 and 8.3.10.1 as follows:

8.3.10 Solar photovoltaic panel structures

8.3.10.1 Sprinklers shall be permitted to be omitted from the following structures:
  1. Solar photovoltaic panel structures with no use underneath. Signs may be provided, as determined by the enforcing agency prohibiting any use underneath including storage.
  2. Solar photovoltaic (PV) panels supported by framing that have sufficient uniformly distributed and unobstructed openings throughout the top of the array (horizontal plane) to allow heat and gases to escape, as determined by the enforcing agency.
 
13R—16 Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies R325.5
70—17 National Electrical Code R107.3, R324.3, R327.2, R327.4
72—16 National Fire Alarm and Signaling Code as amended* R314.1, R314.7.1
  *NFPA 72, Amended Sections as follows:

Revise Section 10.3.1 to read as follows:

10.3.1 Equipment constructed and installed in conformity with this code shall be listed for the purpose for which it is used. Fire alarm systems and components shall be California State Fire Marshal approved and listed in accordance with California Code of Regulations, Title 19, Division 1.

Revise Section 10.3.3 to read as follows:

10.3.3 All devices and appliances that receive their power from the initiating device circuit or signaling line circuit of a control unit shall be California State Fire Marshal listed for use with the control unit.

Revise Section 10.7.1 to read as follows:

10.7.1 Where approved by the authority having jurisdiction, ECS priority signals when evaluated by stakeholders through risk analysis in accordance with 24.3.11 shall be permitted to take precedence over all other signals.

Revise Section 12.3.8.1 to read as follows:

12.3.8.1 The outgoing and return (redundant) circuit conductors shall be permitted in the same cable assembly (i.e., multiconductor cable), enclosure, or raceway only under the following conditions:
  1. For a distance not to exceed 10 ft (3.0 m) where the outgoing and return conductors enter or exit the initiating device, notification appliance, or control unit enclosures
  2. Single drops installed in the raceway to individual devices or appliances
  3. *In a single room not exceeding 1000 ft2 (93 m2) in area, a drop installed in the raceway to multiple devices or appliances that does not include any emergency control function devices
  4. Where the vertically run conductors are contained in a 2-hour rated cable assembly, or enclosed (installed) in a 2-hour rated enclosure or a listed circuit integrity (C.I.) cable, which meets or exceeds a 2-hour fire resistive rating.
Revise Section 14.4.6.1 to read as follows:

14.4.6.1 Testing. Household fire alarm systems shall be tested in accordance with the manufacturer's published instructions according to the methods of Table 14.4.3.2.

Revise Section 17.15 to read as follows:

17.15 Fire Extinguisher Electronic Monitoring Device. A fire extinguisher electronic monitoring device shall indicate those conditions for a specific fire extinguisher required by California Code of Regulations, Title 19, Division 1, Chapter 1, Section 574.2 (c) and California Fire Code to a fire alarm control unit.

Revise Section 21.3.6 to read as follows:

21.3.6 Smoke detectors shall not be installed in unsprinklered elevator hoistways unless they are installed to activate the elevator hoistway smoke relief equipment or where required by Chapter 30 of the California Building Code.

Revise Section 23.8.5.1.2 to read as follows:

23.8.5.1.2 Where connected to a supervising station, fire alarm systems employing automatic fire detectors or waterflow detection devices shall include a manual fire alarm box to initiate a signal to the supervising station.

Exception: Fire alarm systems dedicated to elevator recall control, and supervisory service and fire sprinkler monitoring as permitted in Section 21.3 of NFPA 72.

Revise Section 23.8.5.4.1 to read as follows:

23.8.5.4.1 Systems equipped with alarm verification features shall be permitted under the following conditions:
  1. The alarm verification feature is not initially enabled unless conditions or occupant activities that are expected to cause nuisance alarms are anticipated in the area that is protected by the smoke detectors. Enabling of the alarm verification feature shall be protected by password or limited access.
  2. A smoke detector that is continuously subjected to a smoke concentration above alarm threshold does not delay the system functions of Sections 10.7 through 10.16, 23.8.1.1, or 21.2.1 by more than 30 seconds.
  3. Actuation of an alarm-initiating device other than a smoke detector causes the system functions of Sections 10.7 through 10.16, 23.8.1.1, or 21.2.1 without additional delay.
  4. The current status of the alarm verification feature is shown on the record of completion (see Figure 7.8.2(a), item 4.3).
  5. Operation of a patient room smoke detector in I-2 and R-2.1 Occupancies shall not include an alarm verification feature.
Revise Section 29.3.1 to read as follows:

29.3.1 All devices, combinations of devices, and equipment to be installed in conformity with this chapter shall be approved and listed by the California State Fire Marshal for the purposes for which they are intended.

Revise Section 29.5.2.1.1 to read as follows:

29.5.2.1.1* Smoke and Heat Alarms. Unless exempted by applicable laws, codes, or standards, smoke or heat alarms used to provide a fire-warning function, and when two or more alarms are installed within a dwelling unit, suite of rooms, or similar area, shall be arranged so that the operation of any smoke or heat alarm causes all alarms within these locations to sound.

Note: Exception to 29.5.2.1.1 not adopted by the SFM

Add Section 29.7.2.1 to read as follows:

29.7.2.1
The alarm verification feature shall not be used for household fire warning equipment.

Add Section 29.7.6.7.1 to read as follows:

29.7.6.7.1
The alarm verification feature shall not be used for household fire warning equipment.

Revise Section 23.8.3.4 to read as follows:


29.8.3.4 Specific location requirements. The installation of smoke alarms and smoke detectors shall comply with the following requirements:
  1. Smoke alarms and smoke detectors shall not be located where ambient conditions, including humidity and temperature, are outside the limits specified by the manufacturer's published instructions.
  2. Smoke alarms and smoke detectors shall not be located within unfinished attics or garages or in other spaces where temperatures can fall below 40°F (4°C) or exceed 100°F (38°C).
  3. Where the mounting surface could become considerably warmer or cooler than the room, such as a poorly insulated ceiling below an unfinished attic or an exterior wall, smoke alarms and smoke detectors shall be mounted on an inside wall.
  4. Smoke alarms or smoke detectors shall be installed a minimum of 20 feet horizontal distance from a permanently installed cooking appliance.

    Exceptions: Ionization smoke alarms with an alarm silencing switch or photoelectric smoke alarms shall be permitted to be installed 10 feet (3 m) or greater from a permanently installed cooking appliance.

         Photoelectric smoke alarms shall be permitted to be installed greater than 6 feet (1.8 m) from a permanently installed cooking appliance where the kitchen or cooking area and adjacent spaces have no clear interior partitions and the 10 ft distances would prohibit the placement of a smoke alarm or smoke detector required by other sections of the code.

         Smoke alarms listed for use in close proximity to a permanently installed cooking appliance.
  5. Effective January 1, 2016, smoke alarms and smoke detectors used in household fire alarm systems installed between 6 ft (1.8 m) and 20 ft (6.1 m) along a horizontal flow path from a stationary or fixed cooking appliance shall be listed for resistance to common nuisance sources from cooking.
  6. Installation near bathrooms. Smoke alarms shall be installed not less than a 3-foot (0.91 m) horizontal distance from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by other sections of the code.
  7. Smoke alarms and smoke detectors shall not be installed within a 36 in. (910 mm) horizontal path from the supply registers of a forced air heating or cooling system and shall be installed outside of the direct airflow from those registers.
  8. Smoke alarms and smoke detectors shall not be installed within a 36 in. (910 mm) horizontal path from the tip of the blade of a ceiling-suspended (paddle) fan.
  9. Where stairs lead to other occupied levels, a smoke alarm or smoke detector shall be located so that smoke rising in the stairway cannot be prevented from reaching the smoke alarm or smoke detector by an intervening door or obstruction.
  10. For stairways leading up from a basement, smoke alarms or smoke detectors shall be located on the basement ceiling near the entry to the stairs.
  11. For tray-shaped ceilings (coffered ceilings), smoke alarms and smoke detectors shall be installed on the highest portion of the ceiling or on the sloped portion of the ceiling within 12 in. (300 mm) vertically down from the highest point.
  12. Smoke alarms and detectors installed in rooms with joists or beams shall comply with the requirements of 17.7.3.2.4 of NFPA 72.
  13. Heat alarms and detectors installed in rooms with joists or beams shall comply with the requirements of 17.6.3 of NFPA 72.
 
211—16 Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances R1002.5
259—18 Standard for Test Method for Potential Heat of Building Materials R316.5.7, R316.5.8
275—17 Standard Method of Fire Tests for the Evaluation of Thermal Barriers R316.4
286—15 Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth R302.9.4, R316.6
720—15 Standard for the Installation of Carbon Monoxide (CO) Detectors and Warning Equipment R315.7.1, R315.7.2
     
PCA   Portland Cement Association
5420 Old Orchard Road
Skokie, IL 60077
100—12 Prescriptive Design of Exterior Concrete Walls for One- and Two-family Dwellings (Pub. No. EB241) R301.2.2.5, R404.1.3, R404.1.3.2.1, R404.1.3.2.2, R404.1.3.4, R404.1.4.2, R608.1R608.2, R608.5.1, R608.9.2, R608.9.3
     
SBCA   Structural Building Components Association
6300 Enterprise Lane
Madison, WI 53719
BCSI—2013 (Updated March 2015) Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses R502.11.2, R802.10.3
CFS-BCSI—2008 Cold-formed Steel Building Component Safety Information (CFSBCSI) Guide to Good Practice for Handling, Installing & Bracing of Cold-formed Steel Trusses R505.1.3, R804.3.6
FS100—12 Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies R316.8
     
SFM   State of California
Department of Forestry and Fire Protection
Office of the State Fire Marshal
P.O. Box 944246
Sacramento, CA 944246-2460
SFM 12-3 Releasing Systems for Security Bars in Dwellings R310
SFM 12-7A-1 Exterior Wall Siding and Sheathing  
SFM 12-7A-2 Exterior Window  
SFM 12-7A-3 Horizontal Protection Underside  
SFM 12-7A-4 Decking  
SFM 12-7A-4A Decking Alternate Method A  
SFM 12-7A-5 Ignition Resistant Building Material
(The Office of the State Fire Marshal standards referred to above are found in the California Code of Regulations, Title 24, Part 12.)
R327.2
     
TMS   The Masonry Society
105 South Sunset Street, Suite Q
Longmont, CO 80501
402—2016 Building Code Requirements for Masonry Structures R404.1.2, R606.1, R606.1.1, R606.12.1, R606.12.2.3.1, R606.12.3.1, R703.12
403—2017 Direct Design Handbook for Masonry Structures R606.1, R606.1.1, R606.12.1, R606.12.3.1
404—2016 Standard for the Design of Architectural Cast Stone R606.1
602—2016 Specification for Masonry Structures 606.2.10, R606.2.13, R703.12
     
TPI   Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria, VA 22314
TPI 1—2014 National Design Standard for Metal-plate-connected Wood Truss Construction R502.11.1, R802.10.2
     
UBC   International Code Council, Inc.
500 New Jersey Avenue, NW 6th Floor
Washington, DC 20001
UBC Standard 15-2 Test Standard for Determining the Fire Retardancy of Roof-covering Materials R902
UBC Standard 15-3 Wood Shakes R902
UBC Standard 15-4 Wood Shingles R902
     
UL   UL LLC
333 Pfingsten Road
Northbrook, IL 60062
55A—04 Materials for Built-up Roof Coverings R905.9.2
103—2010 Factory-built Chimneys for Residential Type and Building Heating Appliances—with revisions through July 2012 R202, R1005.3
127—2011 Factory-built Fireplaces—with revisions through May 2015 R1001.11, R1004.1, R1004.5, R1005.4
217—06 Single- and Multiple-station Smoke Alarms—with revisions through October 2015 R314.1.1, R315.1.1
263—2011 Standards for Fire Test of Building Construction and Materials—with revisions through June 2015 Table 302.1(1), Table R302.1(2), R302.2, R302.2.1, R302.2.2, R302.4.1, R302.11.1, Table R312.1(1), R606.2.2
268—2009 Smoke Detectors for Fire Alarm Systems R314.7.1, R314.7.4, R315.7.4
325—02 Door, Drapery, Gate, Louver and Window Operations and Systems—with revisions through May 2015 R309.4
641—2010 Type L, Low-temperature Venting Systems—with revisions through June 2013 R202, R1003.11.5
723—08 Standard for Test for Surface Burning Characteristics of Building Materials—with revisions through August 2013 R202, R302.9.3, R302.9.4, R302.10.1, R302.10.2, R316.3, R316.5.9, R316.5.11, R507.2.2.2R703.14.3, R802.1.5
790—04 Standard Test Methods for Fire Tests of Roof Coverings—with revisions through July 2014 R302.2.4, R902.1
959—2010 Medium Heat Appliance Factory-built Chimneys—with revisions through June 2014 R1005.6
1040—96 Fire Test of Insulated Wall Construction—with revisions through October 2012 R316.6
1256—02 Fire Test of Roof Deck Construction—with revisions through July 2013 R906.1
1479—03 Fire Tests of Through-Penetration Firestops—with revisions through June 2015 R302.4.1.2
1482—2011 Solid-fuel-type Room Heaters—with revisions through August 2015 R1002.2, R1002.5
1618—09 Wall Protectors, Floor Protectors, and Hearth Extensions—with revisions through October 2015 R1004.2
1703—02 Flat-plate Photovoltaic Modules and Panels—with revisions through October 2015 R324.3.1, R902.4, R905.16.4
1715—97 Fire Test of Interior Finish Material—with revisions through January 2013 R316.6
1741—2010 Inverters, Converters, Controllers and Interconnection System Equipment with Distributed Energy Resources—with revisions through January 2015 R324.3.1, R327.4
1777—07 Chimney Liners—with revisions through October 2015 R1003.11.1, R1003.18
1897—12 Uplift Tests for Roof Covering Systems—with revisions through September 2015 R905.17.7
2034—08 Standard for Single- and Multiple-station Carbon Monoxide Alarms—with revisions through March 2015 R314.1.1, R315.1.1
2075—2013 Standard for Gas and Vapor Detectors and Sensors R314.7.4, R315.7.1, R315.7.4
2703—14 Mounting Systems, Mounting Devices, Clamping/Retention Devices and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels R902.4
9540—14 Outline of Investigation for Energy Storage Systems and Equipment R327.2, R327.4
     
ULC   ULC
13775 Commerce Parkway
Richmond, BC V6V 2V4
CAN/ULC S 102.2—2010 Standard Methods for Test for Surface Burning Characteristics of Building Materials and Assemblies R302.10.1, R302.10.2
     
WDMA   Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington, DC 20036-3309
AAMA/WDMA/CSA 101/I.S2/A440—17 North American Fenestration Standard/Specifications for Windows, Doors and Skylights R308.6.9, R609.3
I.S. 11—13 Industry Standard Analytical Method for Design Pressure (DP) Ratings of Fenestration Products R308.6.9.1, R609.3.1
     
WMA World Millwork Alliance (formerly Association of Millwork Distributors Standards AMD)
10047 Robert Trent Parkway
New Port Richey, FL 34655-4649
ANSI WMA 100—2016 Standard Method of Determining Structural Performance Ratings of Side Hinged Exterior Door Systems and Procedures for Component Substitution R609.3
UpCodes Premium