Appendix I Patio Covers

AMENDMENT
This section has been amended at the state or city level.
CALIFORNIA BUILDING CODE — MATRIX ADOPTION TABLE
APPENDIX I — PATIO COVERS

(Matrix Adoption Tables are nonregulatory, intended only as an aid to the code user.
See Chapter 1 for state agency authority and building applications.)
Adopting agency BSC BSC-CG SFM HCD DSA OSHPD BSCC DPH AGR DWR CEC CA SL SLC
1 2 1/AC AC SS SS/CC 1 1R 2 3 4 5
Adopt entire chapter X
Adopt entire chapter as amended (amended sections listed below)
Adopt only those sections that are listed below X
Chapter / Section
I101 X
I102 X
I103 X


The provisions contained in this appendix are not mandatory unless specifically adopted by a state agency, or referenced in the adopting ordinance.


User notes:

About this appendix: Appendix I provides standards applicable to the construction and use of patio covers. It is limited in application to patio covers accessory to dwelling units. Covers of patios and other outdoor areas associated with restaurants, mercantile buildings, offices, nursing homes or other nondwelling occupancies would be subject to standards in the main code and not this appendix.

Code development reminder: Code change proposals to this appendix will be considered by the IBC—Structural Code Development Committee during the 2019 (Group B) Code Development Cycle. See explanation on page ix.

Patio covers shall be permitted to be detached from or attached to dwelling units. Patio covers shall be used only for recreational, outdoor living purposes and not as carports, garages, storage rooms or habitable rooms.

Section I102 Definition

AMENDMENT
This section has been amended at the state or city level.

I102.1 General

AMENDMENT
This section has been amended at the state or city level.

Section I103 Exterior Walls and Openings

AMENDMENT
This section has been amended at the state or city level.
UpCodes note: SEC. 91.3112. PATIO COVERS, Chapter IX of the Los Angeles Municipal Code says, "91.3112.3. Exterior Openings. Section I101.3 of Appendix I of the CBC is adopted by reference." There seems to be a misprint because there is no Section I101.3 of Appendix I of the CBC. We determined this section might be the most relevant for the provision and showing the subsections here for your reference.
Enclosure walls shall be permitted to be of any configuration, provided that the open or glazed area of the longer wall and one additional wall is equal to not less than 65 percent of the area below not less than 6 feet 8 inches (2032 mm) of each wall, measured from the floor. Openings shall be permitted to be enclosed with insect screening, translucent or transparent plastic conforming to the provisions of Sections 2606 through 2610, glass conforming to the provisions of Chapter 24 or any combination of the foregoing.
Exterior openings of the dwelling unit required for light and ventilation shall be permitted to open into a patio structure. However, the patio structure shall be unenclosed if such openings are serving as emergency egress or rescue openings from sleeping rooms. Where such exterior openings serve as an exit from the dwelling unit, the patio structure, unless unenclosed, shall be provided with exits conforming to the provisions of Chapter 10.

Section I104 Height

AMENDMENT
This section has been amended at the state or city level.

I104.1 Height

AMENDMENT
This section has been amended at the state or city level.

Section I105 Structural Provisions

AMENDMENT
This section has been amended at the state or city level.
UpCodes note: SEC. 91.3112. PATIO COVERS, Chapter IX of the Los Angeles Municipal Code says, "91.3112.4. Structural Provisions. Section I101.4 of Appendix I of the CBC is adopted by reference." There seems to be a misprint because there is no Section I101.4 of Appendix I of the CBC. We determined this section might be the most relevant for the provision and showing the subsections here for your reference.
Patio covers shall be designed and constructed to sustain, within the stress limits of this code, all dead loads plus a minimum vertical live load of 10 pounds per square foot (0.48 kN/m2) except that snow loads shall be used where such snow loads exceed this minimum. Such patio covers shall be designed to resist the minimum wind and seismic loads set forth in this code.
In areas with a frost depth of zero, a patio cover shall be permitted to be supported on a concrete slab on grade without footings, provided that the slab conforms to the provisions of Chapter 19 of this code and is not less than 31/2 inches (89 mm) thick, and the columns do not support loads in excess of 750 pounds (3.36 kN) per column.