Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.
AHRI Air Conditioning, Heating and Refrigeration Institute
2111 Wilson Boulevard, Suite 500
Arlington, VA 22201
Standard
reference
number
Title Referenced
in code
section number
810—2007 Standard for Performance Rating of Automatic Commercial Ice-Makers Table 609.2.3
870—2009 Direct Geoexchange Heat Pumps Table 606.2.2.1
AMCA Air Movement and Control Association International
25 West 43rd Street
Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
205—10 Energy Efficiency Classification for Fans 606.2.2.3
220—05 Laboratory Methods of Testing Air Curtain Units for Aerodynamic Performance Rating 605.1.2.3
AITC American Institute of Timber Construction
7012 South Revere Parkway, Suite 140
Englewood, CO 80112
Standard
reference
number
Title Referenced
in code
section number
ANSI/AITC 190.1—2007 Structural Glued Laminated Timber 202
ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
Z21.50/CSA 2.22.2007 Vented Gas Fireplaces 804.1.3
Z21.88a/CSA 2.33a—09 ANSI/CSA Standard for Vented Gas Fireplace Heaters 804.1.3
APHA American Public Health Association
800 I Street NW
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
2005 Standard Methods for Examination of Water and Waste Water-21st Edition 707.15.1.1
ARB California Air Resource Board
1001 "I" Street, P. O. Box 2815
Sacramento, CA 9512
Standard
reference
number
Title Referenced
in code
section number
February 1, 2008 California Air Resources Board, Architectural Coatings Suggested Control Measures
February 1, 2008
Table 806.3(1)
ASA Acoustical Society of America
Suite 1N01
2 Huntington Quadrangle
Melville, NY 11747-4502
Standard
reference
number
Title Referenced
in code
section number
ANSI/ASA S12.60-2010/
Pt.1
Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools,
Part 1: Permanent Schools
Table 807.4.3
ANSI/ASA S12.60-2009/
Pt.2
Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools,
Part 2: Relocatable Classroom Factors
Table 807.4.3
ASABE American Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph, MI 49085
Standard
reference
number
Title Referenced
in code
section number
S313.3-99 (R2009) Soil Cone Penetrometer 405.1.4.2
EP542-99 (R2009) Procedures for Using and Reporting Data Obtained with the Soil Cone Penetrometer 405.1.4.2
ASHE The American Society for Healthcare Engineering of the American Hospital Association
155 N. Wacker Drive, Suite 400
Chicago, IL 60606
Standard
reference
number
Title Referenced
in code
section number
2010 FGI-ASHE Guidelines for Design and Construction of Healthcare Facilities Table 807.3.2
ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
A112.18.1/
CSA B125.1—2010
Plumbing Supply Fittings Table 702.1, 702.2
ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle
Atlanta, GA 30329-2305
Standard
reference
number
Title Referenced
in code
section number
52.2—2007 Method of Testing General Ventilation Air-Cleaning Devices for Removal
Efficiency by Particle Size
803.1.3, 803.5
55—2004 Thermal Environmental Conditions on Human Occupancy 606.5.1, 803.2
62.1—2010 Ventilation for Acceptable Indoor Air Quality 604.3
72—05 Method of Testing Commercial Refrigerators and Freezers Table 609.2.3
90.1—2010 Energy Standard for Buildings Except Low-rise Residential Buildings
(ANSI/ASHRAE/IESNA 90.1-2007)
602.1.2, 602.1.2.1
189.1—2011 Standard for the Design of High-performance Green Buildings,
Except Low-rise Residential Buildings
101.3, 301.1.1
ASSE American Society of Sanitary Engineering
901 Canterbury Road, Suite A
Westlake, OH 44145
Standard
reference
number
Title Referenced
in code
section number
1016—2010 Performance Requirements for Automatic Compensating, Valves for Individual
Showers and Tub/Shower Combinations
Table 702.1
ASTM ASTM International
100 Barr Harbor
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
C 1371—04a Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using
Portable Emissometers
408.3.1.1
C 1549—09 Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature
Using a Portable Solar Reflectometer
408.2.1, 408.3.1.1
D 1253—08 Standard Test Method for Residual Chlorine in Water 707.11.6, 707.15.1.1.2, 708.12.5
D 2974—07a Standard Test Methods for Moisture, Ash, and Organic Matter of Peat and other Organic Soils 405.1.4.2
D 3385—09 Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer 405.1.4.2
D 3960—05 Standard Practice of Determining Volatile Organic Compound (VOC)
Content of Paints & Related Coatings
806.2, 806.3
D 5055—10 Standard Specification for Establishing and Monitoring Structural Capacities
of Prefabricated Wood I-Joists
202
D 5093—02 (2008) Standard Test Method for Field Measurement of Infiltration Rate Using Double-Ring
Infiltrometer With Sealed-Inner Ring
405.1.4.2
D 5197—09 Test Method for Determination of Formaldehyde and Other Carbonyl
Compounds in Air (Active Sampler Methodology)
804.3
D 5456—10 Standard Specification for Evaluation of Structural Composite Lumber Products 202
D 5464—07 Standard Test Method for pH Measurement of Water of Low Conductivity 707.15.1.1.2
D 5466—01 (2007) Test Method for Determination of Volatile Organic Chemicals in
Atmospheres (Canister Sampling Methodology)
804.2
D 5907—10 Standard Test Methods for Filterable Matter (Total Dissolved Solids) and Nonfilterable
Matter (Total Suspended Solids) in Water
707.15.1.1.2
D 6007—02 (2008) Standard Test Method for Determining Formaldehyde Concentrations in Air
from Wood Products Using a Small-Scale Chamber
Table 806.1
D 6196—03 (2009) Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption
Analysis Procedures for Volatile Organic Compounds in Air
804.3
D 6345—10 Standard Guide for Selection of Methods for Active, Integrative Sampling of
Volatile Organic Compounds in Air
804.3
D 6698—07 Standard Test Method for On-Line Measurement of Turbidity Below 5 NTU in Water 707.15.1.1.2
D 6866—11 Standard Test Methods for Determining the Biobased Content of Solid, Liquid,
and Gaseous Samples Using Radiocarbon Analysis
505.2.4
D 7612—10 Standard Practice in Categorizing Wood and Wood-Based Products according to their Fiber Sources 202
E 90—04 Test Method for Laboratory Measurement of Airborne Sound Transmission
Loss of Building Partitions and Elements
807.2, 807.3 807.4.1, 809.2, 809.3
E 336—2010 Standard Test Method for Measurement of Airborne Sound Attenuation Between Rooms in Buildings 807.2
E 408—71 (2008) Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques 408.3.1.1
E 413—10 Classification for Rating Sound Insulation 807.4.1
E 492—09 Standard Test Method for Laboratory Measurement of Impact Sound Transmission
Through Floor-Ceiling Assemblies Using the Tapping Machine
807.4
E 779—10 Standard Test Method for Determining Air Leakage Rate by Ton Pressurization 605.1.2.2
E 1332—90 (2003) Standard Classification for the Determination of Outdoor-Indoor Transmission Class 807.2
E 1333—10 Standard Test Method for Determining Formaldehyde Concentrations in Air and
Emission Rates from Wood Products Using a Large Chamber
Table 806.1
E 1509—04 Standard Specification for Room Heaters, Pellet Fuel-Burning Type 804.1.6
E 1643—10 Standard Practice for Selection, Design, Installation, and Inspection of Water Vapor
Retarders Used in Contact with Earth or Granules Fill Under Concrete Slabs
804.2.2, Table 903.1
E 1918—06 Standard Test Method for Measuring Solar Reflectance of Horizontal and Low-Sloped
Surfaces in the Field
408.2.1, 408.3.1.1
E 1980—11 Standard Practice for Calculating Solar Reflectance Index of Horizontal
and Low-Sloped Opaque Surfaces
408.3.1.2
E 2399—11 Standard Test Method for Maximum Media Density for Dead Load Analysis of
Vegetative (Green) Roof Systems
408.3.2
E 2635—08 Standard Practice for Water Conservation in Buildings Through In-Situ Water Reclamation 709.9
E 2727—10 Standard Practice for Assessment of Rainwater Quality 707.12.10
F 1275—03 (2008) Standard Test Method for Performance of Griddles Table 609.2.3
F 1346—91 (2010) Standard Performance Specification for Safety Covers and Labeling Requirements for
All Covers for Swimming Pools, Spas and Hot Tubs
1003.2.5
F 1361—07 Standard Test Method for Performance of Open Deep Fat Fryers Table 609.2.3
F 1496—99 (2005)e1 Standard Test Method for Performance of Convection Ovens Table 609.2.3
F 1484—05 Standard Test Methods for Performance of Steam Cookers Table 609.2.3
F 1605—95 (2007) Standard Test Method for Performance of Double-Sided Griddles Table 609.2.3
F 1639—05 Standard Test Method for Performance of Combination Ovens 702.17
F 1696—07 Standard Test Method for Energy Performance of Single-Rack, Door-Type
Commercial Dishwashing Machines
Table 609.2.3
F 1920—11 Standard Test Method for Performance of Rack Conveyor, Commercial
Dishwashing Machines
Table 609.2.3
F 2140—11 Standard Test Method for Performance of Hot Food Holding Cabinets Table 609.2.3
F 2144—09 Standard Test Method for Performance of Large Open Vat Fryers Table 609.2.3
F 2861—10 Standard Test Method for Enhanced Performance of Combination Oven in Various Modes Table 609.2.3
CCR California Code of Regulations
Department of Industrial Relations
Office of the Director
455 Golden Gate Avenue
San Francisco, CA 94102
Standard
reference
number
Title Referenced
in code
section number
Section 93120—Title 17 California Code Regulations, Airborne Toxic Control Measure to
Reduce Formaldehyde Emissions from Composite Wood Products
806.1
CDPH California Department of Public Health
1615 Capitol Avenue
Sacramento, CA 95814
Standard
reference
number
Title Referenced
in code
section number
CDPH Section 01350 EHLB Standard Method for Testing VOC Emissions From Indoor Sources 806.2
CRRC Cool Roof Rating Council
1610 Harrison Street
Oakland, CA 94612
Standard
reference
number
Title Referenced
in code
section number
CRRC—1 2010 Cool Roof Rating Council, CRRC-1 Standard 404.3.1.1
CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4N 5N6
Standard
reference
number
Title Referenced
in code
section number
CAN/CSA B366.1—2009 Solid-Fuel-Fired Central Heating Appliances 804.1.6
CSA Z21.50/CSA 2.22—07 Vented Gas Fireplaces 804.1.3
CSA Z21.88a/CSA 2.33a—09 ANSI/CSA Standard for Vented Gas Fireplace Heaters 804.1.3
DCHS California Department of Health Services
Office of Regulations
P.O. Box 997413, MS 0015
Sacramento, CA 95899-7413
Standard
reference
number
Title Referenced
in code
section number
CA/DHS/EHLB/
R-174—2010
Standard Method for the Testing and Evaluation of Volatile Organic Chemical
Emissions from Indoor Sources using Environmental Chambers
Version 1.1 February 2010
806.2, Table 806.2(2), 806.3,
Table 806.2(2), 806.5, 806.6, 809.2.4
DOC U.S. Department of Commerce
National Institute of Standards and Technology
1401 Constitution Avenue NW
Washington, DC 20230
Standard
reference
number
Title Referenced
in code
section number
PS1—09 Structural Plywood 202
PS2—10 Performance Standard for Wood-Based Structural-Use Panels 202
DOE U.S. Department of Energy
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
10 CFR Part 431 Sub-Part K, Appendix C Table 609.8.1.1(1), Table 609.8.1.1(2), Table 609.8.1.1(3)
EPA Environmental Protection Agency
Ariel Rios Building
1200 Pennsylvania Avenue, NW
Washington, DC 20460
Standard
reference
number
Title Referenced
in code
section number
40 CFR,
Part 60 Subpart AAA
EPA Standards of Performance for New Residential Wood Heaters 804.1.5
40 CFR 300 Small Business Liability Relief and Brownfield Revitalization Act-Public Law 107-118 202
EPAct 2005 Energy Policy Act 2005 608.8.1.1
EPA eGRID 2007 Version 1.1; 2005 data; EPA eGrid Data 602.1.2.3, Table 602.1.2.1, 602.2.1, Table 602.2.1
ENERGY STAR Energy Star 202, 702.6.1, 702.6.2, 702.6.4
US EPA Method 24 Determination of Volatile Matter Content, Water Content, Density, Volume Solids
and Weight Solids of Surface Coatings
806.2
Water Sense February 2007 High Efficiency Toilet Specification Table 702.1
Water Sense October 2007 Lavatory Faucet Specification Table 702.1
Water Sense October 2009 Flushing Urinal Specification Table 702.1
Water Sense March 2010 Showerhead Specification Table 702.1
FSC Forest Stewardship Council
212 Third Avenue, North, Suite 504
Minneapolis, MN 55401
Standard
reference
number
Title Referenced
in code
section number
STD-40-004 V2-1EN—2011 Standard for Chain of Custody Certification 505.2.4
ICC International Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
IBC—12 International Building Code® 101.3, 101.3.1, 102.4, 102.4.1, 102.6, 103.1, 104.1,
201.3, 202, 303.1, 402.1.1.3, 402.2.3, 407.3.2, 407.4,
410.2.1.2, 605.1.1.1, 608.3, 608.4.1, 608.5, 609.2, 610.2.2, 703.7.1,
710.14.1, 803.1.2.1, 804.1.7, Table 903.1, 1004.1, 1104.1
ICCPC—12 International Code Council Performance Code® 102.4
IEBC—12 International Existing Building Code® 102.4, 102.6
IECC—12 International Energy Conservation Code® 102.4, 102.6, 201.3, 202, 604.4, 605.1, 605.1.1, 605.1.1.1,
605.1.2, 605.1.2.1, 605.1.2.3, 606.1, 606.2.1, 606.3, 606.5,
606.8, 606.8.1, 607.1, 607.2.1, 607.3, 607.4, 608.1, 608.8.1.1,
608.1.1.2, 608.1.1.3, 608.5, 608.7, 608.9, 608.11, 609.2, 611.1,
611.1.4.3, 611.3, 611.3.2, 611.3.3.1, 611.3.3.3, 611.4, 611.4.2,
Table 903.1, 1003.2.2, 1003.2.4, 1003.2.7, 1104.1
IFC—12 International Fire Code® 102.4, 102.6, 201.3, 408.3.2, 608.3, 608.4.1, 610.2.2
IFGC—12 International Fuel Gas Code® 102.4, 201.3, 603.3.1, 609.2, 804.1.2
IMC—12 International Mechanical Code® 102.4, 201.3, 603.3.2, 604.3, 606.7, 606.8.1,
609.2, 611.1.2.1, 703.7, 803.1.2.1, 803.3, 804.1.2
IPC—12 International Plumbing Code® 102.4, 201.3, 609.2, 704.1.3, 704.2, 705.2, 707.2,
707.4, 707.10, 707.11.3.2, 707.11.4.1, 707.11.4.2, 707.11.4.3, 707.11.7.2,
707.11.7.4, 707.11.7.6, 707.11.7.11, 707.11.10, 707.11.12.1, 707.11.12.1,
707.11.12.2, 707.11.12.3, 707.12.1, 707.12.2, 707.12.3, 707.12.4,
708.3, 708.5, 708.10, 708.12.1.1, 708.12.2, 708.12.3.1, 708.12.3.2,
708.12.3.3, 708.12.6.4, 708.12.6.5, 708.12.6.7, 708.12.6.9, 708.12.8,
708.12.9, 708.12.9.3, 708.12.10.1, 708.12.10.2, 708.12.10.3, 708.13.1,
708.13.2, 708.13.3, 708.13.4, 709.3, 709.4, 709.6, 709.7, 709.8,
709.9.1.1, 709.9.1.2, 709.9.1.3, 709.10.1, 709.10.2
IPMC—12 International Property Maintenance Code® 102.4, 102.6
IRC—12 International Residential Code® 102.4, 201.3, 804.2
ICC-700—2008 National Green Building Standard 101.3.1, 302.1, Table 302.1
IEC The International Electrotechnical Commission
Central Office
3, rue de Varembe'
P. O. Box 131
Ch-1211 Geneva 20, Switzerland
Standard
reference
number
Title Referenced
in code
section number
EN60034-30—2009 Standard on Efficiency Classes for Low Voltage AC Motors 609.2.1.2.1, 609.2.2.2
IESNA Illuminating Engineering Society of North America
120 Wall Street, 17th Floor
New York, NY 10005-4001
Standard
reference
number
Title Referenced
in code
section number
TM-15—07 Luminaire Classification System for Outdoor Luminaires Table 405.3(2), Table 409.2,
Table 409.3(1), Table 409.3(2)
ISO International Organization for Standardization
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case Postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
Title Referenced
in code
section number
7708—1995 Air quality — Particle Size Fraction Definitions for Health-related Sampling 804.3
13256-1—1998 Water-source Heat Pumps — Testing and Rating for Performance —
Part 1: Water-to-air and Brine-to-air Heat Pumps
Table 606.2.2.1
13256-2—1998 Water-source Heat Pumps — Testing and Rating for Performance —
Part 2: Water-to-water and Brine-to-water Heat Pumps
Table 606.2.2.1
14044—2006 Environmental Management — Lifecycle Assessment—Requirements and Guidelines 303.1
ISO/IEC 17025—2005
2004—11
General Requirements for the Competence of Testing and Calibration
Laboratories
806.2, Table 806.2(2), 806.3,
806.4, 806.5, 806.6, 809.2.4
NEMA National Electrical Manufacturers Association
1300 North 17th Street, Suite 1752
Rosslyn, VA 22209
Standard
reference
number
Title Referenced
in code
section number
LSD 23—2010 Recommended Practice —Lamp Seasoning for Fluorescent Dimming Systems 611.3.3.4
NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Standard
reference
number
Title Referenced
in code
section number
NFPA 70—2011 National Electrical Code 603.3.4, 610.2.2, 610.3
NFPA 72—2010 National Alarm and Signaling Code 710.6.2
NREL National Renewable Energy Laboratory
1617 Cole Boulevard
Golden, CO 80401-3305
Standard
reference
number
Title Referenced
in code
section number
SERI TR-642-761 A Simplified Clear Sky Model for Direct and Diffuse Insolation on Horizontal Surfaces 610.2.1
NSF NSF International
789 Dixboro Road
Ann Arbor, MI 48105
Standard
reference
number
Title Referenced
in code
section number
NSF/ANSI 3—10 Commercial Warewashing Equipment Table 609.2.3
NSF/ANSI 44—09 Residential Cation Exchange Water 704.1.2, 704.1.4
NSF/ANSI 50—09 Equipment for Swimming Pools, Spas, Hot Tubs, and other Recreational Water Facilities 708.12.7.1
NSF/ANSI 58—09 Reverse Osmosis Drinking Water Treatment Systems 704.2
NSF/ANSI 61—09 Drinking Water Systems Components — Health Effects 707.15
NSF/P151—95 Health Effects from Rain Water Catchment Systems Components 707.11.1.1
NSF 350—11 Onsite Residential and Commercial Water Reuse Treatment Systems 704.3
SCAQMD South Coast Air Quality Management District
21865 Capley Drive
Diamond Bar, CA 91765
Standard
reference
number
Title Referenced
in code
section number
SCAQMD Method 302—91
(Revised 1993)
Distillation of Solvents from Paints, Coatings and Inks, South Coast Air Quality Management District 803.2
SCAQMD Method 303—91
(Revised 1993)
Determination of Exempt Compounds, South Coast Air Quality Management District 803.2
SCAQMD Method 304—91
(Revised February 1996)
Determination of Volatile Organic Compounds (VOC) in Various
Materials, South Coast Air Quality Management District
803.2
SCAQMD Method 316A—92 Determination of Volatile Organic Compounds (VOC) in Materials Used for Pipes and Fittings 803.2
SCAQMD Method 316B—92 Determination of Volatile Organic Compounds (VOC) In Adhesives containing Cyanoacrylates 803.2
SCAQMD Rule 1168 Adhesives and Sealant Applications 806.2
SFI Sustainable Forest Initiative, Inc.
900 17th Street, NW, Suite 700
Washington, DC 20006
Standard
reference
number
Title Referenced
in code
section number
SFI—2010-2014 Sustainable Forest Initiative 2010-2014 505.2.4
SMACNA Sheet Metal & Air Conditioning Contractors National Assoc., Inc.
4021 Lafayette Center Road
Chantilly, VA 22021
Standard
reference
number
Title Referenced
in code
section number
2010 SMACNA HVAC Air Duct Leakage Test Manual (1st Edition) 606.3.1
TCIA Tree Care Industry Association
136 Harvey Road, Suite 101
Londonderry, NH 03053
Standard
reference
number
Title Referenced
in code
section number
ANSI A300 Part 5—2005 Tree Shrub and Other Woody Plt Mgmt-Management of Trees
and Shrubs during Site Planning, Site Development, and Construction
405.2.1.1
TMS The Masonry Society
3970 Broadway, Unit 201-D
Boulder, CO 80304-1135
Standard
reference
number
Title Referenced
in code
section number
0302—2011 Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls 809.3, 809.5.1
UL Underwriters Laboratories Inc.
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
Title Referenced
in code
section number
UL 1482—2011 Room Heaters, Solid Fuel Type 804.1.6
UL 1993—2009 Standard for Safety of Self-Ballasted Lamps and Lamp Adapters 506.3
UL 2523—2009 Solid Fuel-Fired Hydronic Heating Appliances, Water Heaters and Boilers 804.1.6
USCC US Composting Council
1 Comac Loop 14 B1
Rokonkoma, NY 11779
Standard
reference
number
Title Referenced
in code
section number
TMECC 05.7a Test Method for the Examination of Composting and Compost 405.1.2
USDA United States Department of Agriculture
Office of Energy Policy and New Uses
Room 361, Reporters Bldg.
300 Seventh Street, SW
Washington, DC 20024
Standard
reference
number
Title Referenced
in code
section number
7 CFR Part 2902
Rev. 1/1/06
Guidelines for Designating Bio-based Products for Federal Procurement 505.2.4
MP 1475—90 USDA Plant Hardiness Zone Map, Miscellaneous Publication 1475 408.3.2
Linked Resources
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Code Compare
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.