ANSI
A118.10—99
Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin Set Ceramic Tile and Dimension Stone Installation
421.5.2.5, 421.5.2.6
Z21.22—99 (R2003)
Relief Valves for Hot Water Supply Systems with Addenda Z21.22a—2000 (R2003) and Z21.22b—2001 (R2003)
ASHRAE
ASHRAE 18—2008 (RA13)
Method of Testing for Rating Drinking-Water Coolers with Self-contained Mechanical Refrigeration (ANSI/ASHRAE Approved)
410.1
ASME
A112.1.2—2012
Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water Connection Receptors)
406.1, 409.2, Table 608.1, 608.14.1
A112.1.3—2000 (R2015)
Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances
406.1, 409.2, Table 608.1, 608.14.1, 1102.6
A112.3.1—2007 (R2012)
Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground
413.1, Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, 1102.6, Table 1102.7
A112.4.2—2015/CSA B45.16—15
Water Closet Personal Hygiene Devices
412.9
A112.4.3—1999 (R2010)
Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System
405.4
A112.4.14—2004 (R2016)
Manually Operated, Quarter-turn Shutoff Valves for Use in Plumbing Systems
A112.6.2—2000 (R2016)
Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks
405.4.3
A112.14.4—2001 (R2012)
Grease Removal Devices
1003.3.5
A112.18.3—2002 (R2012)
Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings
412.2, 412.6
A112.19.1—2013/CSA B45.2—2013
Enameled Cast Iron and Enameled Steel Plumbing Fixtures
A112.19.3—2008/CSA B45.4—08(R2013)
Stainless Steel Plumbing Fixtures
A112.19.5—2017/CSA B45.15—2017
Flush Valves and Spuds for Water-closets, Urinals, and Tanks
415.4
A112.19.14—2013
Six-liter Water Closets Equipped with a Dual Flushing Device
425.1
A112.19.19—2006(R2011)
Vitreous China Nonwater Urinals
424.1
ASSE 1016—2017/ASME A112.1016—2017/CSA B125.16—2017
Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings
ASSE 1037—2015/ASME A112.1037—2015/CSA B125.37—
Pressurized Flushing Devices for Plumbing Fixtures
415.2
B16.22—2013
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings
Table 605.5, Table 702.4, Table 1102.7
B16.28—1994
Wrought Steel Buttwelding Short Radius Elbows and Returns
Table 605.5, Table 702.4, Table 1102.7
B16.29—2012
Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings (DWV)
Table 702.4, Table 1102.7
ASPE
ASSE
1001—2016
Performance Requirements for Atmospheric Type Vacuum Breakers
415.2, Table 608.1, 608.14.6, 608.17.4.1
1003—09
Performance Requirements for Water Pressure Reducing Valves
604.8
1004—2016
Performance Requirements for Commercial Dishwashing Machines
409.1
1010—04
Performance Requirements for Water Hammer Arresters
604.9
1012—09
Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent
Table 608.1, 608.14.3, 608.17.2, 608.17.10
1013—2017
Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers
Table 608.1, 608.14.2, 608.17.2
1015—2017
Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies
Table 608.1, 608.14.7
ASSE 1016—2017/ASME A112.1016—2017/CSA B125.16—2017
Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings
1019—2016
Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type
Table 608.1, 608.14.6
1022—2016
Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment
Table 608.1, 608.17.1.1, 608.17.1.2
1024—2016
Performance Requirements for Dual Check Valve Type Backflow Preventers, Anti-siphon-type, Residential Applications
605.3.1, Table 608.1, 608.14.9, 608.17.1.2
ASSE 1037—2015/ASME A112.1037—2015/CSA B125.37—15
Pressurized Flushing Devices for Plumbing Fixtures
415.2
1047—2017
Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies
Table 608.1, 608.14.2
1048—2017
Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies
Table 608.1, 608.14.7
1049—2009
Performance Requirements for Individual and Branch Type Air Admittance Valves for Chemical Waste Systems
901.3, 918.8
1050—2009
Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems
918.1
1051—2009
Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systemsfixture and Branch Devices
918.1
1055—2016
Performance Requirements for Chemical Dispensing Systems
608.14.8
1060—2016
Performance Requirements for Outdoor Enclosures for Fluid Conveying Components
608.15.1
1062—2016
Performance Requirements for Temperature Actuated, Flow Reduction (TAFR) Valves to Individual Supply Fittings
1066—2016
Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings
604.11
1069—05
Performance Requirements for Automatic Temperature Control Mixing Valves
412.4
1072—07
Performance Requirements for Barrier Type Floor Drain Tap Seal Protection Devices
5013—2015
Performance Requirements for Testing Reduced Pressure Principle Backflow Prevention Assembly (RPA) and Reduced Pressure Fire Protection Backflow Preventers (RFP)
312.10.2
5047—2015
Performance Requirements for Testing Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies (RPDA)
312.10.2
5048—2015
Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA)
312.10.2
ASTM
A53/A53M—12
Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless
Table 605.3, Table 605.4, Table 702.1
A74—15
Specification for Cast-iron Soil Pipe and Fittings
Table 702.1, Table 702.2, Table 702.3, Table 702.4, 708.1.6, Table 1102.4, Table 1102.5, Table 1102.7
A312/A312M—15a
Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes
Table 605.3, Table 605.4, Table 605.5, 605.22.2
A733—15
Specification for Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples
A778/A778M—15
Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products
Table 605.3, Table 605.4, Table 605.5
A888—15
Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Application
Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7
B75/B75M—11
Specification for Seamless Copper Tube
Table 605.3, Table 605.4, Table 702.1, Table 702.2, Table 702.3, Table 1102.4
B88—14
Specification for Seamless Copper Water Tube
Table 605.3, Table 605.4, Table 702.1, Table 702.2, Table 702.3, Table 1102.4
B251—10
Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube
Table 605.3, Table 605.4, Table 702.1, Table 702.2, Table 702.3, Table 1102.4
B302—12
Specification for Threadless Copper Pipe, Standard Sizes
Table 605.3, Table 605.4, Table 702.1
C4—04(2014)
Specification for Clay Drain Tile and Perforated Clay Drain Tile
Table 702.3, Table 1102.4, Table 1102.5
C14—15a
Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe
Table 702.3, Table 1102.4
C76—15a
Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe
Table 702.3, Table 1102.4
C700—13
Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated
Table 702.3, Table 702.4, Table 1102.4, Table 1102.5
C1053—00(2010)
Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications
Table 702.1, Table 702.4
C1440—08(2013)
Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
705.16
C1460—2012
Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground
705.16
C1461—08(2013)
Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use
705.19
C1540—15
Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings
705.3.3
D1527—99(2005)
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80
D1785—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120
D2235—04(2011)
Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings
605.10.2, 705.2.2
D2239—12a
Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter
D2282—99(2005)
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)
D2464—15
Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
Table 605.5, 605.21.3
D2468—96a
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40
D2661—14
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings
Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.2.2, Table 1102.4, Table 1102.7
D2665—14
Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.7
D2683—14
Standard Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing
Table 605.5, Table 702.4, 716.5
D2729—11
Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
Table 1102.5, Table 1403.2
D2751—05
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings
Table 702.3, Table 702.4, Table 1102.7
D2846/D2846M—14
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution Systems
Table 605.3, Table 605.4, Table 605.5, 605.14.2, 605.15.2
D2949—10
Specification for 3.25-in. Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.7
D3034—14a
Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7
D3035—15
Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter
D3138—04(2011)
Standard Specification for Solvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Non-pressure Piping Components
D3261—12e1
Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing
D4068—15
Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed Water-containment Membrane
D4551—12
Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane
421.5.2.1
E2635—14
Standard Practice for Water Conservation Through In-Situ Water Reclamation
1302.1
F409—12
Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings
412.1.2, Table 1102.7
F437—15
Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F438—15
Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40
F439—13
Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F441/F441M—15
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe,Schedules 40 and 80
Table 605.3, Table 605.4
F442/F442M—13e1
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)
Table 605.3, Table 605.4
F493—14
Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings
605.14.2
605.15.2
F628—12e1
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core
Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.2.2, Table 1102.4, Table 1102.7
F667—12
Standard Specification for 3 through 24 in. Corrugated Polyethylene Pipe and Fittings
F714—2013
Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter
F877—11a
Specification for Cross-linked Polyethylene (PEX) Hot- and Cold-water Distribution Systems
F891—10
Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core
Table 702.1, Table 702.2Table 702.3, Table 1102.4, Table 1102.5, Table 1102.7
F1055—13
Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Cross-linked Polyethylene Pipe and Tubing
F1281—11
Specification for Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe
Table 605.3, Table 605.4, Table 605.5, 605.20.1
F1282—10
Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe
Table 605.3, Table 605.4, Table 605.5, 605.20.1
F1412—09
Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage
Table 702.1, Table 702.2, Table 702.4, 705.13.1, 901.3
F1476—07(2013)
Standard Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications
Table 605.5, 605.13.3, 605.17.3, 605.22.2, 605.22.3
F1488—14
Specification for Coextruded Composite Pipe
Table 702.1, Table 702.2, Table 702.3, Table 1102.4, Table 1403.2
F1548—01(2012)
Standard Specification for the Performance of Fittings for Use with Gasketed Mechanical Couplings Used in Piping Applications
F1673—10
Standard Specification for Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems
Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.14.1
F1807—15
Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
F1866—13
Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings
Table 702.4, Table 1102.7
F1960—15
Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing
F1970—12e1
Special Engineered Fittings, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) OR Chlorinated Poly (Vinyl Chloride) (CPVC) Systems
F1974—09(2015)
Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/ Aluminum/Cross-linked Polyethylene Composite Pressure Pipe
Table 605.5, 605.20.1
F1986—01(2011)
Specification for Multilayer Pipe, Type 2, Compression Fittings and Compression Joints for Hot and Cold Drinking Water Systems
Table 605.3, Table 605.4, Table 605.5
F2080—15
Specifications for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe
F2098—08
Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Fittings
F2159—14
Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
F2262—09
Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9
Table 605.3, Table 605.4
F2306/F2306M—14e1
12" to 60" Annular Corrugated Profile-wall Polyethylene (PE) Pipe and Fittings for Gravity Flow Storm Sewer and Subsurface Drainage Applications
Table 1102.4, Table 1102.7
F2389—15
Specification for Pressure-rated Polypropylene (PP) Piping Systems
Table 605.3, Table 605.4, Table 605.5, Table 605.7, 605.19.1
F2434—14
Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX AL-PEX) Tubing
F2648/F2648M—13
Standard Specification for 2 to 60 inch [50 to 1500 mm] Annular Corrugated Profile Wall Polyethylene (PE) Pipe and Fittings for Land Drainage Applications
F2735—09
Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing
F2736—13e1
Standard Specification for 6 to 30 in. [152 to 762 mm] Polypropylene (PP) Corrugated Single Wall Pipe and Double Wall Pipe
F2764/F2764M—11ae2
Standard Specification for 30 to 60 in. [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-pressure Sanitary Sewer Applications
F2769—14
Polyethylene or Raised Temperature (PE-RT) Plastic Hot- and Cold-water Tubing and Distribution Systems
Table 605.3, Table 605.4, Table 605.5
F2831—12
Standard Practice for Internal Non Structural Epoxy Barrier Coating Material Used in Rehabilitation of Metallic Pressurized Piping Systems
601.5
F2855—12
Standard Specification for Chlorinated Poly (Vinyl Chloride)/Aluminum/Chlorinated Poly (Vinyl Chloride) (CPVC/AL/ CPVC) Composite Pressure Tubing
Table 605.3, Table 605.4
F2881—11
Standard Specification for 12 to 60 in. [300 to 1500 mm] Polypropylene (PP) Dual Wall Pipe and Fittings for Non-pressure Storm Sewer Applications
AWS
AWWA
C115/A21.15—11
Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges
Table 605.3, Table 605.4
C652—11
Disinfection of Water-storage Facilities
610.1
C901—16
Polyethylene (PE) Pressure Pipe and Tubing 3/4 inch (19 mm) Through 3 inch (76 mm) for Water Service
C904—16
Cross-linked Polyethylene (PEX) Pressure Tubing 1/2 inch (13 mm) Through 3 inch (76 mm) for Water Service
CISPI
301—12
Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications
Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7
CSA
A257.1M—14
Non-reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
Table 702.3, Table 1102.4
A257.2M—14
Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
Table 702.3, Table 1102.4
ASME A112.19.1—2013/CSA B45.2—2013
Enameled Cast-iron and Enameled Steel Plumbing Fixtures
ASME A112.19.3—2008/CSA B45.4—08(R2013)
Stainless-steel Plumbing Fixtures
ASME A112.19.5—2017/CSA B45.15—17
Flush Valves and Spuds for Water Closets, Urinals and Tanks
415.4
ASSE 1037—2015/ASME A112.1037—2015/CSA B125.37—15
Pressurized Flushing Devices for Plumbing Fixtures
415.2
B64.2.2—16
Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature
Table 608.1, 608.14.6
B64.3—16
Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP)
Table 608.1, 608.14.3, 608.17.2
B137.1—16
Polyethylene (PE) Pipe, Tubing and Fittings for Cold-water Pressure Services
Table 605.3, Table 605.5
B137.2—16
Polyvinylchloride, PVC, Injection-moulded Gasketed Fittings for Pressure Applications
B137.3—16
Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications
Table 605.3, Table 605.5, 605.21.3, 705.10.2, 705.14.2
B137.5—16
Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications
Table 605.3, Table 605.4, Table 605.5
B137.6—16
CPVC Pipe, Tubing and Fittings for Hot- and Cold-water Distribution Systems
Table 605.3, Table 605.4, Table 605.5
B137.9—16
Polyethylene Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-pipe Systems
Table 605.3, Table 605.5, 605.20.1
B137.10—16
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Composite Pressure-pipe Systems
Table 605.3, Table 605.4, Table 605.5, 605.20.1
B137.11—16
Polypropylene (PP-R) Pipe and Fittings for Pressure Applications
Table 605.3, Table 605.4, Table 605.5
B137.18—13
Polyethylene of Raised Temperature Resistance (PE-RT) Tubing Systems for Pressure Applications
Table 605.3, Table 605.4, Table 605.5
B181.1—15
Acrylonitrile-Butadiene-Styrene ABS Drain, Waste and Vent Pipe and Pipe Fittings
Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.2.2, 714.2, Table 1102.4, Table 1102.7
B181.2—15
Polyvinylchloride PVC and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings
Table 702.1, Table 702.2, 705.10.2, 705.14.2, 714.2
B181.3—15
Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Drainage Systems
Table 702.1, Table 702.2, Table 702.3, Table 702.4, 705.13.1
B182.1—11
Plastic Drain and Sewer Pipe and Pipe Fittings
705.10.2, 705.14.2, Table 1102.4, Table 1102.5
B182.2—11
PSM Type Polyvinylchloride PVC Sewer Pipe and Fittings
Table 702.3, Table 1102.4, Table 1102.5
B182.4—15
Profile Polyvinylchloride PVC Sewer Pipe and Fittings
Table 702.3, Table 1102.4, Table 1102.5
B182.13—11
Profile Polypropylene (PP) Sewer Pipe and Fittings for Leak-proof Sewer Applications
Table 702.3, Table 1102.4
B356—10
Water Pressure Reducing Valves for Domestic Water Systems
604.8
IAPMO
ICC
IPSDC—18
International Private Sewage Disposal Code®
701.2
ICC 900/SRCC 300—2015
Solar Thermal System Standard
502.1
ISEA
ANSI/ISEA Z358.1—2014
Emergency Eyewash and Shower Equipment
411.1
MSS
SP-139—2014
Copper Alloy Gate, Globe, Angle and Check Valves for Low Pressure/Low Temperature Plumbing Applications
NFPA
51—18
Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes
1203.1
55—16
Compressed Gases and Cryogenic Fluids Code
1203.1
99—18
Health Care Facilities Code
1202.1
NGWA
NSF
3—2012
Commercial Warewashing Equipment
409.1
18—2012
Manual Food and Beverage Dispensing Equipment
426.1
62—2015
Drinking Water Distillation Systems
611.1
184—2014
Residential Dishwashers
409.1
350—2014
Onsite Residential and Commercial Water Reuse Treatment Systems
1302.6.1
372—2011
Drinking Water Systems Components—Lead Content
605.2.1
PDI
PDI G101(2012)
Testing and Rating Procedure for Grease Interceptors with Appendix of Sizing and Installation Data
1003.3.5
PDI G102(2009)
Testing and Certification for Grease Interceptors with Fog Sensing and Alarm Devices
1003.3.5
PSAI
UL
508—99
Industrial Control Equipment—with revisions through October 2013
314.2.3
1795—2009
Hydromassage Bathtubs—with revisions through January 2015
426.1