Heads up: There are no suggested sections in this chapter.
Heads up: There are no amended sections in this chapter.

ANSI

American National Standards Institute
25 West 43rd Street
4th Floor
New York NY 10036

ANSI A13.1—2015

Scheme for the Identification of Piping Systems

704.1.2.2

ANSI FC 1—2012

Stationery Fuel Cell Power Systems

633.1

ANSI NGV 5.1—2015

Residential Fueling Appliances

413.4.1

LC 1/CSA 6.26—2013

Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST)

403.5.5

ANSI LC-4/CSA 6.32—2012

Press-connect Metallic Fittings for Use in Fuel Gas Distribution Systems

403.10.1, 403.10.2, 403.10.3

Z21.1—2010

Household Cooking Gas Appliances

623.1

Z21.5.1/CSA 7.1—2014

Gas Clothes Dryers—Volume I—Type 1 Clothes Dryers

613.1

Z21.5.2/CSA 7.2—2014

Gas Clothes Dryers—Volume II—Type 2 Clothes Dryers

613.1, 614.3

Z21.8—94 (R2002)

Installation of Domestic Gas Conversion Burners

619.1

Z21.10.1/CSA 4.1—2012

Gas Water Heaters—Volume I—Storage, Water Heaters with Input Ratings of 75,000 Btu per Hour or Less

624.1

Z21.10.3/CSA 4.3—2011

Gas Water Heaters—Volume III—Storage, Water Heaters with Input Ratings above 75,000 Btu per Hour, Circulating and Instantaneous

624.1

Z21.11.2—2011

Gas-fired Room Heaters—Volume II—Unvented Room Heaters

621.1

Z21.13/CSA 4.9—2011

Gas-fired Low-pressure Steam and Hot Water Boilers

631.1

Z21.15/CSA 9.1—2009

Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves

Table 409.1.1

Z21.19/CSA 1.4—02(R2007)

Refrigerators Using Gas (R1999) Fuel

625.1

Z21.24/CSA 6.10—2006

Connectors for Gas Appliances

411.1, 411.3

Z21.40.1/CGA 2.91—1996 (R2011)

Gas-fired Heat Activated Air Conditioning and Heat Pump Appliances

627.1

Z21.40.2/CGA 2.92—1996 (R2011)

Gas-fired Work Activated Air Conditioning and Heat Pump Appliances (Internal Combustion)

627.1

Z21.42—2014

Gas-fired Illuminating Appliances

628.1

Z21.47/CSA 2.3—2012

Gas-fired Central Furnaces

618.1

Z21.50/CSA 2.22—2016

Vented Gas Fireplaces

604.1

Z21.54—2009

Gas Hose Connectors for Portable Outdoor Gas-fired Appliances

411.1

Z21.56/CSA 4.7—2017

Gas-fired Pool Heaters

617.1

Z21.58/CSA 1.6—2013

Outdoor Cooking Gas Appliances

623.1

Z21.60/CSA 2.26—2012

Decorative Gas Appliances for Installation in Solid-fuel Burning Fireplaces

602.1

Z21.61—1983 (R2004)

Gas-fired Toilets

626.1

Z21.69/CSA 6.16—2009

Connectors for Movable Gas Appliances

411.1.1, 411.1.4

Z21.75/CSA 6.27—2007

Connectors for Outdoor Gas Appliances and Manufactured Homes

411.1, 411.2

Z21.80/CSA 6.22—2011

Line Pressure Regulators

410.1

Z21.84—2012

Manually Lighted, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces

602.1, 602.2

Z21.86/CSA 2.32—2008

Vented Gas-fired Space Heating Appliances

608.1, 609.1, 622.1

Z21.88/CSA 2.33—2016

Vented Gas Fireplace Heaters

605.1

Z21.91—2007

Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters

621.7.1

Z21.93/CSA 6.30—2013

Excess Flow Valves for Natural and LP Gas with Pressures up to 5 psig

410.4

Z21.97—2012

Outdoor Decorative Appliances

636.1

Z83.4/CSA 3.7—2012

Nonrecirculating Direct-gas-fired Industrial Air Heaters

611.1

Z83.8/CSA 2.6—2009

Gas Unit Heater, Gas Packaged Heater, Gas Utility Heaters and Gas-fired Duct Furnaces

610.1, 620.1

Z83.11/CSA 1.8—2013

Gas Food Service Equipment

623.1

Z83.18—2012

Recirculating Direct Gas-fired Industrial Air Heaters

612.1

Z83.19—2001(R2009)

Gas-fired High-intensity Infrared Heaters

630.1

Z83.20—2008

Gas-fired Low-intensity Infrared Heaters

630.1

ASME

American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016-5990

B1.20.1—2013

Pipe Threads, General Purpose (inch)

403.9

B16.1—2010

Gray Iron Pipe Flanges and Flanged Fittings, Class 25, 125 and 250

403.12.1

B16.5—2015

Pipe Flanges and Flanged Fittings: NPS 1/2 through NFPS 24 Metric/Inch Standard

403.12.2

B16.24—2016

Cast Copper Alloy Pipe Flanges and Flanged Fittings: Classes 150, 300, 600, 900, 1500 and 2500

403.12.3

B16.42—2016

Ductile Iron Pipe Flanges and Flanged Fittings, Classes 150 and 300

403.12.4

B16.47—2016

Large Diameter Steel Flanges: NPS 26 through NPS 60 Metric/Inch Standard

403.12.2

B16.33—2012

Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2)

Table 409.1.1

B16.44—2012

Manually Operated Metallic Gas Valves for Use in Aboveground Piping Systems up to 5 psi

Table 409.1.1

B31.3—2016

Process Piping

704.1.2.4

B31.12—2014

Hydrogen Piping and Pipelines

704.1.2, 704.1.2.4, 705.2, 705.3

B36.10M—(R2015)

Welded and Seamless Wrought-steel Pipe

403.4.2

BPVC—2015

ASME Boiler & Pressure Vessel Code (2007 Edition)

631.1, 703.2.2, 703.3.3, 703.3.4

CSD-1—2016

Controls and Safety Devices for Automatically Fired Boilers

631.1

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959

A53/A53M—12

Specification for Pipe, Steel, Black and Hot Dipped Zinc-coated Welded and Seamless

403.4.2

A106/A106M—14

Specification for Seamless Carbon Steel Pipe for High-temperature Service

403.4.2

A254—12

Specification for Copper Brazed Steel Tubing

403.5.1

A268—10

Standard Specification for Seamless and Welded Ferritic and Martensitic Stainless Steel Tubing for General Service

403.5.2

A269—15

Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service

403.5.2

A312—15

Standard Specification for Seamless, Welded and Heavily Cold Worked Austenitic Stainless Steel Pipes

403.4.2

B88—14

Specification for Seamless Copper Water Tube

403.5.3

B210—12

Specification for Aluminum and Aluminum-alloy Drawn Seamless Tubes

403.5.4

B241/B241M—12e1

Specification for Aluminum and Aluminum-alloy, Seamless Pipe and Seamless Extruded Tube

403.4.4, 403.5.4

B280—13

Standard Specification for Seamless Copper Tube for Air-Conditioning and Refrigeration Field Service

403.5.3

C315—07(2011)

Specification for Clay Flue Liners and Chimney Pots

501.12

D2513—14e1

Specification for Polyethylene (PE) Gas Pressure Pipe, Tubing and Fittings

403.6, 403.6.1, 403.11, 404.17.2

E136—16

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C

202

F1973—13e1

Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA11) and Polyamide 12 (PA12) Fuel Gas Distribution Systems

404.17.2

F2945—15

Standard Specification for Polyamide 11 Gas Pressure Pipe, Tubing and Fittings

403.6

CGA

Compressed Gas Association
14501 George Carter Way, Suite 103
Chantilly VA 20151-2923

S-1.1—(2017)

Pressure Relief Device Standards—Part 1—Cylinders for Compressed Gases

703.3

S-1.2—(2009)

Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases

703.3

S-1.3—(2016)

Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases

703.3

CSA

CSA Group
8501 East Pleasant Valley Road
Cleveland OH 44131-5516

ANSI/CSA FC1—2014

Fuel Cell Technologies—Part 3-100; Stationary fuel cell power systems-Safety

633.1

CSA 8—93

Requirements for Gas-fired Log Lighters for Wood Burning Fireplaces

603.1

ANSI/CSA NGV 5.1—2015

Residential Fueling Appliances

413.4.1

DOTn

U.S.Department of Transportation
400 Seventh St. SW
Washington DC 20590

49 CFR, Parts 192.281(e) & 192.283 (b)—(2009)

Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards

403.6.1

49 CFR—Parts 100—180(2015)

Hazardous Materials Regulations

703.2.2, 703.3.3, 703.3.4

ICC

International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington DC 20001

MSS

Manufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, NE
Vienna VA 22180

ANSI SP 58—2009

Pipe Hangers and Supports—Materials, Design and Manufacture

407.2

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471

2—16

Hydrogen Technologies Code

703.1, 706.2

30A—18

Code for Motor Fuel Dispensing Facilities and Repair Garages

305.4, 305.10

37—18

Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines

616.1

51—18

Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes

414.1

58—17

Liquefied Petroleum Gas Code

401.2, 402.7, 403.6.2, 403.11

70—17

National Electrical Code

306.3.1, 306.4.1, 306.5.2, 309.2, 413.9.2.4, 703.6

82—14

Incinerators, Waste and Linen Handling Systems and Equipment

503.2.5, T503.4, 607.1

85—15

Boiler and Combustion Systems Hazards Code

631.1

88A—15

Parking Structures

305.9

211—16

Standard for the Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances

503.5.2, 503.5.3, 503.5.6.1, 503.5.6.3

409—16

Standard for the Aircraft Hangars

305.11

853—15

Installation of Stationary Fuel Cell Power Systems

633.1

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062

103—2010

Factory-built Chimneys, Residential Type and Building Heating Appliances— with Revisions through July 2012

506.1

127—2011

Factory-built Fireplaces—with Revisions through May 2015

621.7

378—2006

Draft Equipment

503.3.3

441—2010

Gas Vents—with Revisions through June 2014

502.1

641—2010

Type L Low-temperature Venting Systems—with Revisions through June 2013

502.1

651—2011

Schedule 40 and 80 Rigid PVC Conduit and Fittings—with Revisions through May 2014

403.6.3

795—2011

Commercial-industrial Gas Heating Equipment— with Revisions through November 2013

610.1, 618.1, 631.1

959—2010

Medium Heat Appliance Factory-built Chimneys—with Revisions through June 2014

506.3

1618—09

Wall Protectors, Floor Protectors and Hearth Extensions—with Revisions through October 2015

308.2

1738—2010

Venting Systems for Gas Burning Appliances, Categories II, III and IV— with Revisions through November 2014

502.1, 503.4.1

1777—2007

Chimney Liners—with Revisions through October 2015

501.12, 501.15.4

2200—2012

Stationary Engine Generator Assemblies—with Revisions through July 2015

616.1

Analyzing code differences
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING