Chapter 8 Referenced Standards (IFGC/IFGS)

AMENDMENT
This section has been amended at the state or city level.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ANSI American National Standards Institute
25 West 43rd Street
Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
ANSI A13.1—2007 Scheme for the Identification of Piping Systems 704.1.2.2
ANSI CSA-America FC 1—03 Stationery Fuel Cell Power Systems 633.1
LC 1/CSA 6.26—05 Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) 403.5.4
ANSI LC-4—07 Press-connect Copper and Copper Alloy Fittings for Use In Fuel Gas Distribution Systems 403.10.2
Z21.1—05 Household Cooking Gas Appliances 623.1
Z21.5.1/CSA 7.1—06 Gas Clothes Dryers—Volume I—Type 1 Clothes Dryers 613.1
Z21.5.2/CSA 7.2—05 Gas Clothes Dryers—Volume II—Type 2 Clothes Dryers 613.1, 614.3
Z21.8—94 (R2002) Installation of Domestic Gas Conversion Burners 619.1
Z21.10.1/CSA 4.1—09 Gas Water Heaters—Volume I—Storage, Water Heaters with Input Ratings of 75,000 Btu per Hour or Less 624.1
Z21.10.3/CSA 4.3—04 Gas Water Heaters—Volume III—Storage, Water Heaters with Input Ratings Above 75,000 Btu per hour, Circulating and Instantaneous 624.1
Z21.11.2—07 Gas-fired Room Heaters-Volume II-Unvented Room Heaters 621.1
Z21.13/CSA 4.9—10 Gas-fired Low-pressure Steam and Hot Water Boilers 631.1
Z21.15/CGA 9.1—09 Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves 409.1.1
Z21.19/CSA 1.4—02(R2007) Refrigerators Using Gas (R1999) Fuel 625.1
Z21.24/CGA 6.10—06 Connectors for Gas Appliances 411.1
Z21.40.1/CGA 2.91—96
(R2002)
Gas-Fired Heat Activated Air Conditioning and Heat Pump Appliances 627.1
Z21.40.2/CGA 2.92—96
(R2002)
Gas-Fired Work Activated Air Conditioning and Heat Pump Appliances (Internal Combustion) 627.1
Z21.42—93 (R2002) Gas-Fired Illuminating Appliances 628.1
Z21.47/CSA 2.3—06 Gas-Fired Central Furnaces 618.1
Z21.50/CSA 2.22—07 Vented Gas Fireplaces 604.1
Z21.56/CSA 4.7—06 Gas-Fired Pool Heaters 617.1
Z21.58/CSA 1.6—07 Outdoor Cooking Gas Appliances 623.1
Z21.60/CSA 2.26—03 Decorative Gas Appliances for Installation in Solid-fuel Burning Fireplaces 602.1
Z21.61—83 (R2004) Gas-fired Toilets 626.1
Z21.69/CSA 6.16—09 Connectors for Movable Gas Appliances 411.1.1
Z21.75/CSA 6.27—07 Connectors for Outdoor Gas Appliances and Manufactured Homes 411.1, 411.2
Z21.80—03(R2008) Line Pressure Regulators 410.1
Z21.84—02 Manually-lighted, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces—with Addenda Z21.84a-2003 602.1, 602.2
Z21.86—08 Vented Gas-fired Space Heating Appliances 608.1, 609.1, 622.1
Z21.88/CSA 2.33—09 Vented Gas Fireplace Heaters 605.1
Z21.91—07 Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters 621.7.1
Z21.97—09 Outdoor Decorative Appliances 636
Z83.4/CSA 3.7—03 Nonrecirculating Direct-gas-fired Industrial Air Heaters 611.1
Z83.6—90 (R1998) Gas-fired Infrared Heaters 630.1
Z83.8/CSA 2.6—09 Gas Unit Heater, Gas Packaged Heater, Gas Utility Heaters and Gas-fired Duct Furnaces 620.1
Z83.11/CSA 1.8—06 Gas Food Service Equipment 623.1
Z83.18—04 Recirculating Direct Gas-fired Industrial Air Heaters 612.1
Z83.19—01(R2005) Gas-fired High-intensity Infrared Heaters 630.1
Z83.20—08 Gas-fired Low-intensity Infrared Heaters 630.1
ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—83
(Reaffirmed 2006)
Pipe Threads, General Purpose (inch) 403.9
B16.1—2005
(Reaffirmed 2004)
Cast-iron Pipe Flanges and Flanged Fittings, Class 25, 125 and 250 403.12
B16.20—98
(Reaffirmed 2007)
Metallic Gaskets for Pipe Flanges Ring-joint, Spiral-wound and Jacketed 403.12
B16.33—02
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2) 409.1.1
B16.44—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in Aboveground Piping Systems Up to 5 psi 409.1.1
B31.3—04 Process Piping 704.1.2, 704.1.2.4, 705.2, 705.3
B36.10M—2004 Welded and Seamless Wrought-steel Pipe 403.4.2
BPVC—07 ASME Boiler & Pressure Vessel Code (2007 Edition). 631.1, 703.2.2, 703.3.3, 703.3.4
CSD-1—2009 Controls and Safety Devices for Automatically Fired Boilers 631.1
ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A 53/A 53M—07 Specification for Pipe, Steel, Black and Hot Dipped Zinc-coated Welded and Seamless 403.4.2
A 106/A 106M—08 Specification for Seamless Carbon Steel Pipe for High-temperature Service 403.4.2
A 254—97 (2007) Specification for Copper Brazed Steel Tubing 403.5.1
B 88—03 Specification for Seamless Copper Water Tube 403.5.2
B 210—04 Specification for Aluminum and Aluminum-alloy Drawn Seamless Tubes 403.5.3
B 241/B 241M—02 Specification for Aluminum and Aluminum-alloy, Seamless Pipe and Seamless Extruded Tube 403.4.4, 403.5.3
C 315—07 Specification for Clay Flue Liners and Chimney Pots 501.12
D 2513—09 Specification for Polyethylene (PE) Gas Pressure Pipe, Tubing and Fittings 403.6, 403.6.1, 403.11, 404.17.2
D 2513—08b Specification for Thermoplastic Gas Pressure Pipe, Tubing and Fittings 403.6
F 1973—08 Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA11) and Polyamide 12 (PA12) Fuel Gas Distribution Systems 404.17.2
CGA Compressed Gas Association
1725 Jefferson Davis High way, 5th Floor
Arlington, VA 22202-4102
Standard
reference
number
Title Referenced
in code
section number
S-1.1—(2002) Pressure Relief Device Standards—Part 1—Cylinders for Compressed Gases 703.3
S-1.2—(1995) Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases 703.3
S-1.3—(1995) Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases 703.3
CSA CSA America Inc.
8501 E. Pleasant Valley Rd.
Cleveland, OH USA 44131-5575
Standard
reference
number
Title Referenced
in code
section number
ANSI CSA America FC1—03 Stationary Fuel Cell Power Systems 633.1
CSA 8—93 Requirements for Gas-fired Log Lighters for Wood Burning Fireplaces—with Revisions through January 1999 603.1
DOTn Department of Transportation
400 Seventh St. SW.
Washington, DC 20590
Standard
reference
number
Title Referenced
in code
section number
49 CFR, Parts 192.281(e)
& 192.283 (b)—(2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards 403.6.1
49 CFR Parts 100—180 Hazardous Materials Regulations 703.2.2, 703.3.3, 703.3.4
ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
IBC—12 International Building Code® 102.2.1,201.3,301.10,301.11,301.12,301.14,302.1,302.2,305.6,306.6,401.1.1,
412.6,413.3,413.3.1,501.1,501.3,501.12,501.15.4,609.3,614.2,706.2,706.3
IECC—12 International Energy Conservation Code® 301.2
IFC—12 International Fire Code® 201.3,401.2,412.1,412.6,412.7,412.7.3,412.8,413.1,413.3,413.3.1,413.5,413.9.2.5,701.1,
701.2,703.2,703.2.2,703.3.8,703.4,703.5,704.1.2,704.3,704.4,706.2,706.3,707.1,707.2,708.1
IMC—12 International Mechanical Code® 101.2.5,201.3,301.1.1,301.13,304.11,501.1,614.2,618.5,621.1,624.1,631.2,632.1,703.1.2
IPC—12 International Plumbing Code® 201.3,301.6,624.1.1,624.2
IRC—12 International Residential Code® 703.2.1
UpCodes note: IDAPA 07.07.01 indicates that "All references to the International Plumbing Code (IPC)
shall be construed as referring to the Idaho State Plumbing Code (ISPC) as adopted and amended by the Idaho State Plumbing Board."
MSS Manufacturers Standardization Society of
the Valve and Fittings Industry
127 Park Street, Northeast
Vienna, VA 22180
Standard
reference
number
Title Referenced
in code
section number
SP-6—01 Standard Finishes for Contact Faces of Pipe Flanges and Connecting-end Flanges of Valves and Fittings 403.12
SP-58—93 Pipe Hangers and Supports—Materials, Design and Manufacture 407.2
NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
Standard
reference
number
Title Referenced
in code
section number
30A—12 Code for Motor Fuel Dispensing Facilities and Repair Garages 305.4
37—10 Installation and Use of Stationary Combustion Engines and Gas Turbines 616.1
51—02 Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes 414.1
58—11 Liquefied Petroleum Gas Code 401.2, 402.6, 403.11
70—11 National Electrical Code 306.3.1, 306.4.1, 306.5.2, 309.2, 413.9.2.4, 703.6
82—09 Incinerators, Waste and Linen Handling Systems and Equipment 503.2.5, 607.1
85—11 Boiler and Combustion Systems Hazards Code 631.1
88A—11 Parking Structures 305.9
211—10 Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 503.5.2, 503.5.3, 503.5.6.1, 503.5.6.3
409—10 Aircraft Hangars 305.11
853—10 Installation of Stationary Fuel Cell Power Systems 633.1
UL Underwriters Laboratories Inc.
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
Title Referenced
in code
section number
103—2001 Factory-built Chimneys, Residential Type and Building Heating Appliances—with Revisions through March 2010 506.1
127—08 Factory-built Fireplaces—with Revisions through January 2010 621.7
441—2010 Gas Vents—with Revisions through August 2006 502.1
641—95 Type L Low-temperature Venting Systems—with Revisions through July 2009 502.1
651—05 Schedule 40 and 80 Rigid PVC Conduit and Fittings—with Revisions through March 2010 403.6.3
795—2006 Commercial-industrial Gas Heating Equipment—with Revisions through April 2010 610.1, 618.1, 631.1
959—01 Medium Heat Appliance Factory-built Chimneys—with Revisions through June 2010 506.3
1738—1993 Venting Systems for Gas Burning Appliances, Categories II, III and IV—with Revisions through October 2006 502.1
1777—2007 Chimney Liners—with Revisions through July 2009 501.12, 501.15.4
2200—98 Stationary Engine Generator Assemblies—with Revisions through December 2009 616.1