This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 106.
AAMA | American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL 60173-4268 | |
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A C440—11 | North American Fenestration Standard/ Specifications for Windows, Doors and Unit Skylights | Table C402.5.2 |
AHAM | Association of Home Appliance Manufacturers 1111 19th Street, NW, Suite 402 Washington, DC 20036 | |
Standard reference number | Title | Referenced in code section number |
ANSI/ AHAM RAC-1—2008 | Room Air Conditioners | Table C403.2.3(3) |
AHAM HRF-1—2007 | Energy, Performance and Capacity of Household Refrigerators, Refrigerator- Freezers and Freezers | Table C403.2.14.1 |
AHRI | Air-Conditioning, Heating, and Refrigeration Institute 2111 Wilson Blvd, Suite 500 Arlington, VA 22201 | |
Standard reference number | Title | Referenced in code section number |
ISO/AHRI/ASHRAE 13256-1 (2011) | Water-to-Air and Brine-to-Air Heat Pumps—Testing and Rating for Performance | Table C403.2.3(2) |
ISO/AHRI/ASHRAE 13256-2 (2011) | Water-to-Water and Brine-to-Water Heat Pumps —Testing and Rating for Performance | Table C403.2.3(2) |
210/240—08 with Addenda 1 and 2 | Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment | Table C403.2.3(1), Table C403.2.3(2) |
310/380—04 (CSA-C744-04) | Standard for Packaged Terminal Air Conditioners and Heat Pumps | Table C403.2.3(3) |
340/360—2007 with Addendum 2 | Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment | Table C403.2.3(1), Table C403.2.3(2) |
365(I-P)—09 | Commercial and Industrial Unitary Air-Conditioning Condensing Units | Table C403.2.3(1), Table C403.2.3(6) |
390—03 | Performance Rating of Single Package Vertical Air-Conditioners and Heat Pumps | Table C403.2.3(3) |
400—2001 | Liquid to Liquid Heat Exchangers with Addendum 1 and 2 | Table C403.2.3(10) |
440—2008 | Performance Rating of Room Fan Coils | C403.2.10 |
460—2005 | Performance Rating of Remote Mechanical-Draft Air-Cooled Refrigerant Condensers | Table C403.2.3(8) |
550/590—2011 With Addendum 1 | Performance Rating of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle | C403.2.3.1, Table C403.2.3(7) |
560—00 | Absorption Water Chilling and Water Heating Packages | Table C403.2.3(7) |
1160 (I-P) —09 | Performance Rating of Heat Pump Pool Heaters | Table C404.2 |
1200-2010 | Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets | C403.2.14, Table C403.2.14(1), Table C403.2.14(2) |
AMCA | Air Movement and Control Association International 30 West University Drive Arlington Heights, IL 60004-1806 | |
Standard reference number | Title | Referenced in code section number |
205—12 | Energy Efficiency Classification for Fans | C403.2.12.3 |
220—08 (R2012) | Laboratory Methods of Testing Air Curtain Units for Aerodynamic Performance Rating | C402.5.6 |
500D—12 | Laboratory Methods for Testing Dampers for Rating | C403.2.4.3 |
ANSI | American National Standards Institute 25 West 43rd Street Fourth Floor New York, NY 10036 | |
Standard reference number | Title | Referenced in code section number |
Z21.10.3/CSA 4.3—11 | Gas Water Heaters, Volume III—Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous | Table C404.2 |
Z21.47/CSA 2.3—12 | Gas-fired Central Furnaces | Table C403.2.3(4) |
Z83.8/CSA 2.6—09 | Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces | Table C403.2.3(4) |
APSP | The Association of Pool and Spa Professionals 2111 Eisenhower Avenue Alexandria, VA 22314 | |
Standard reference number | Title | Referenced in code section number |
14—11 | American National Standard for Portable Electric Spa Efficiency | C404.8 |
ASHRAE | American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1791 Tullie Circle, NE Atlanta, GA 30329-2305 | |
Standard reference number | Title | Referenced in code section number |
ASHRAE 127-2007 | Method of Testing for Rating Computer | Table C403.2.3(9) |
ANSI/ASHRAE/ACCA Standard 183—2007 (RA2011) | Peak Cooling and Heating Load Calculations in Buildings, Except Low-rise Residential Buildings | C403.2.1 |
ASHRAE—2012 | ASHRAE HVAC Systems and Equipment Handbook | C403.2.1 |
ISO/AHRI/ASHRAE 13256-1 (2011) | Water-to-Air and Brine-to-Air Heat Pumps—Testing and Rating for Performance | Table C403.2.3(2) |
ISO/AHRI/ASHRAE 13256-2 (2011) | Water-to-Water and Brine-to-Water Heat Pumps—Testing and Rating for Performance | Table C403.2.3(2) |
90.1—2013 | Energy Standard for Buildings Except Low-rise Residential Buildings | C401.2, Table C402.1.3, Table C402.1.4, C406.2, Table C407.6.1, C502.1, C503.1, C504.1 |
140—2011 | Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs | C407.6.1 |
146—2011 | Testing and Rating Pool Heaters | Table C404.2 |
ASME | American Society Mechanical Engineers Two Park Avenue New York, NY 10016-5990 | |
Standard reference number | Title | Referenced in code section number |
ASME A17.1/ CSA B44—2013 | Safety Code for Elevators and Escalators | C405.9.2 |
ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2859 | |
Standard reference number | Title | Referenced in code section number |
C 90—13 | Specification for Load-bearing Concrete Masonry Units | Table C401.3 |
C 1363—11 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus. | C303.1.4.1, Table C402.1.4 |
C 1371—04a(2010)e1 | Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers | Table C402.3 |
C 1549—09 | Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using A Portable Solar Reflectometer | Table C402.3 |
D 1003—11e1 | Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics | C402.4.2.2 |
E 283—04 | Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen | C402.5.1.2.2, Table C402.5.2, C402.5.7 |
E 408—71(2008) | Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques | Table C402.3 |
E 779—10 | Standard Test Method for Determining Air Leakage Rate by Fan Pressurization | C402.5 |
E 903—96 | Standard Test Method Solar Absorptance, Reflectance and Transmittance of Materials Using Integrating Spheres (Withdrawn 2005) | Table C402.3 |
E 1677—11 | Standard Specification for an Air-retarder (AR) Material or System for Low-rise Framed Building Walls | C402.5.1.2.2 |
E 1918—06 | Standard Test Method for Measuring Solar Reflectance of Horizontal or Low-sloped Surfaces in the Field | Table C402.3 |
E 1980—11 | Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces | Table C402.3, C402.3.2 |
E 2178—13 | Standard Test Method for Air Permanence of Building Materials | C402.5.1.2.1 |
E 2357—11 | Standard Test Method for Determining Air Leakage of Air Barriers Assemblies | C402.5.1.2.2145 |
CRRC | Cool Roof Rating Council 449 15th Street, Suite 200 Oakland, CA 94612 | |
Standard reference number | Title | Referenced in code section number |
ANSI/CRRC-1—2012 | CRRC-1 Standard | Table C402.3, C402.3.2, C402.3.2.1, Table C407.5.1(1) |
CSA | CSA Group 8501 East Pleasant Valley Cleveland, OH 44131-5516 | |
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A440—11 | North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights | Table C402.5.2 |
CSA B55.1—2012 | Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units | C404.8 |
CSA B55.2—2012 | Drain Water Heat Recover Units | C404.8 |
CTI | Cooling Technology Institute P. O. Box 73383 Houston, TX 77273-3383 | |
Standard reference number | Title | Referenced in code section number |
ATC 105 (00) | Acceptance Test Code for Water Cooling Tower | Table C403.2.3(8) |
ATC 105S—11 | Acceptance Test Code for Closed Circuit Cooling Towers | Table C403.2.3(8) |
ATC 106—11 | Acceptance Test For Mechanical Draft Evaporative Vapor Condensers | Table C403.2.3(8) |
STD 201—11 | Standard for Certification of Water Cooling Towers Thermal Performances | Table C403.2.3(8) |
DASMA | Door and Access Systems Manufacturers Association 1300 Sumner Avenue Cleveland, OH 44115-2851 | |
Standard reference number | Title | Referenced in code section number |
105—92 (R2004)—13 | Test Method for Thermal Transmittance and Air Infiltration of Garage Doors | C303.1.3, Table C402.5.2 |
DOE | U.S. Department of Energy c/o Superintendent of Documents 1000 Independence Avenue SW Washington, DC 20585 | |
Standard reference number | Title | Referenced in code section number |
10 CFR, Part 430—1998 | Energy Conservation Program for Consumer Products: Test Procedures and Certification and Enforcement Requirement for Plumbing Products; and Certification and Enforcement Requirements for Residential Appliances; Final Rule | Table C403.2.3(4), Table C403.2.3(5), Table C404.2 |
10 CFR, Part 430, Subpart B, Appendix N—1998 | Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers | C202 |
10 CFR, Part 431—2004 | Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures and Efficiency Standards; Final Rules | Table C403.2.3(5), C405.7, C405.8, Table C405.8 |
10 CFR 431 Subpart B App B | Uniform Test Method for Measuring Nominal Full Load Efficiency of Electric Motors | C403.4.4.4, Table C405.8(1), Table C405.8(2), Table C405.8(3), C405.8(4) |
NAECA 87—(88) | National Appliance Energy Conservation Act 1987 [(Public Law 100-12 (with Amendments of 1988-P.L. 100-357)] | Tables C403.2.3(1), C403.2.3(2), C403.2.3(4) |
ICC | International Code Council, Inc. 500 New Jersey Avenue, NW 6th Floor Washington, DC 20001 | |
Standard reference number | Title | Referenced in code section number |
IBC—15 | International Building Code® | C201.3, C303.2, C402.5.3, C501.4 |
IFC—15 | International Fire Code® | C201.3, C501.4 |
IFGC—15 | International Fuel Gas Code® | C201.3, C501.4 |
IMC—15 | International Mechanical Code® | C403.2.4.3, C403.2.6, C403.2.6.1, C403.2.6.2, C403.2.7, C403.2.8, C403.2.8.1, C403.2.8.2, C403.2.9, C403.4.4, C403.4.4.6, C406.6, C501.4 |
IPC—15 | International Plumbing Code® | C201.3, C501.4 |
IMPC—15 | International Property Maintenance Code® | C501.4 |
IPSDC—15 | International Private Sewage Disposal Code® | C501.4 |
IEEE | The Institute of Electrical and Electronic Engineers Three Park Avenue New York, NY 10016 | |
Standard reference number | Title | Referenced in code section number |
IEEE 515.1—2012 | IEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Commercial Applications | C404.6.2 |
IES | Illuminating Engineering Society 120 Wall Street, 17th Floor New York, NY 10005-4001 | |
Standard reference number | Title | Referenced in code section number |
ANSI/ASHRAE/IESNA 90.1—2013 | Energy Standard for Buildings, Except Low-rise Residential Buildings | C401.2, Table C402.1.3, Table C402.1.4, C406.2, C502.1, C503.1, C504.1 |
ISO | International Organization for Standardization 1, rue de Varembe, Case postale 56, CH-1211 Geneva, Switzerland | |
Standard reference number | Title | Referenced in code section number |
ISO/AHRI/ASHRAE 13256-1 (2011) | Water-to-Air and Brine-to-air Heat Pumps -Testing and Rating for Performance | Table C403.2.3(2) |
ISO/AHRI/ASHRAE 13256-2(2011) | Water-to-Water and Brine-to-Water Heat Pumps -Testing and Rating for Performance | C403.2.3(2) |
NEMA | National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, VA 22209 | |
Standard reference number | Title | Referenced in code section number |
MG1—1993 | Motors and Generators | C202 |
NFPA | National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02169-7471 | |
Standard reference number | Title | Referenced in code section number |
70—14 | National Electrical Code | C501.4 |
NFRC | National Fenestration Rating Council, Inc. 6305 Ivy Lane, Suite 140 Greenbelt, MD 20770 | |
Standard reference number | Title | Referenced in code section number |
100—2009 | Procedure for Determining Fenestration Products U-factors—Second Edition | C303.1.3, C402.2.2 |
200—2009 | Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence—Second Edition | C303.1.3, C402.4.1.1 |
400—2009 | Procedure for Determining Fenestration Product Air Leakage—Second Edition | Table C402.5.2 |
SMACNA | Sheet Metal and Air Conditioning Contractors National Association, Inc. 4021 Lafayette Center Drive Chantilly, VA 20151-1209 | |
Standard reference number | Title | Referenced in code section number |
SMACNA—2012 | HVAC Air Duct Leakage Test Manual 2nd Edition | C403.2.8.1.3 |
UL | UL LLC 333 Pfingsten Road Northbrook, IL 60062-2096 | |
Standard reference number | Title | Referenced in code section number |
710—12 | Exhaust Hoods for Commercial Cooking Equipment | C403.2.8 |
727—06 | Oil-fired Central Furnaces—with Revisions through April 2010 | Table C403.2.3(4) |
731—95 | Oil-fired Unit Heaters—with Revisions through August 2012 | Table C403.2.3(4) |
1784—01 | Air Leakage Tests of Door Assemblies— with Revisions through July 2009 | C402.5.3 |
US-FTC | United States-Federal Trade Commission 600 Pennsylvania Avenue NW Washington, DC 20580 | |
Standard reference number | Title | Referenced in code section number |
CFR Title 16 (May 31, 2005) | R-value Rule | C303.1.4 |
WDMA | Window and Door Manufacturers Association 2025 M Street, NW, Suite 800 Washington, DC 20036-3309 | |
Standard reference number | Title | Referenced in code section number |
AAMA/WDMA/CSA 101/I.S.2/A440—11) | North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights | Table C402.5.2 |