CODES

ADOPTS WITH AMENDMENTS:

International Residential Code 2012 (IRC 2012)

Copyright

Preface

Effective Use of the International Residential Code

Legislation

Part I ‒ Administrative

Chapter 1 Scope and Administration

Part II ‒ Definitions

Chapter 2 Definitions

Part III ‒ Building Planning and Construction

Chapter 3 Building Planning

Chapter 4 Foundations

Chapter 5 Floors

Chapter 6 Wall Construction

Chapter 7 Wall Covering

Chapter 8 Roof-Ceiling Construction

Chapter 9 Roof Assemblies

Chapter 10 Chimneys and Fireplaces

Part IV ‒ Energy Conservation

Chapter 11 [Re] Energy Efficiency

Part V ‒ Mechanical

Chapter 12 Mechanical Administration

Chapter 13 General Mechanical System Requirements

Chapter 14 Heating and Cooling Equipment and Appliances

Chapter 15 Exhaust Systems

Chapter 16 Duct Systems

Chapter 17 Combustion Air

Chapter 18 Chimneys and Vents

Chapter 19 Special Appliances, Equipment and Systems

Chapter 20 Boilers and Water Heaters

Chapter 21 Hydronic Piping

Chapter 22 Special Piping and Storage Systems

Chapter 23 Solar Energy Systems

Part VI ‒ Fuel Gas

Chapter 24 Fuel Gas

Part VII Plumbing Administration

Chapter 25 Plumbing Administration

Chapter 26 General Plumbing Requirements

Chapter 27 Plumbing Fixtures

Chapter 28 Water Heaters

Chapter 29 Water Supply and Distribution

Chapter 30 Sanitary Drainage

Chapter 31 Vents

Chapter 32 Traps

Chapter 33 Storm Drainage

Part VIII ‒ Electrical

Chapter 34 General Requirements

Chapter 35 Electrical Definitions

Chapter 36 Services

Chapter 37 Branch Circuit and Feeder Requirements

Chapter 38 Wiring Methods

Chapter 39 Power and Lighting Distribution

Chapter 40 Devices and Luminaires

Chapter 41 Appliance Installation

Chapter 42 Swimming Pools

Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits

Part IX ‒ Referenced Standards

Chapter 44 Referenced Standards

Appendix A Sizing and Capacities of Gas Piping

Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances, and Appliances Listed for Use With Type B Vents

Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems

Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation

Appendix E Manufactured Housing Used as Dwellings

Appendix F Radon Control Methods

Appendix G Swimming Pools, Spas and Hot Tubs

Appendix H Patio Covers

Appendix I Private Sewage Disposal

Appendix J Existing Buildings and Structures

Appendix K Sound Transmission

Appendix L Permit Fees

Appendix M Home Day Care—R-3 Occupancy

Appendix N Venting Methods

Appendix O Automatic Vehicular Gates

Appendix P Sizing of Water Piping System

Appendix Q Icc International Residential Code Electrical Provisions/National Electrical Code Cross Reference

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.

AAMAAmerican Architectural Manufacturers Association
1827 Walden Office Square, Suite 550
Schaumburg, IL 60173
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standards/Specifications for Windows,
Doors and Skylights
R308.6.9, R612.3, N1102.4.3
450—09 Voluntary Performance Rating Method for Mulled Fenestration AssembliesR612.8
506—08Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration ProductsR612.6.1
711—07Voluntary Specification for Self-adhering Flashing Used for Installation of
Exterior Wall Fenestration Products
R703.8
ACIAmerican Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
Title Referenced
in code
section number
318—11Building Code Requirements for Structural ConcreteR301.2.2.2.4, R301.2.2.3.4, Table R402.1.2(2),
R402.2, R404.1.2, Table R404.1.2(5),
Table R404.1.2(7), Table R404.1.2(8), Table R404.1.2(9),
R404.1.2.1, R404.1.2.3, R404.1.2.4, R404.1.4.2, R404.5.1, R611.1,
R611.1.1, R611.1.2, R611.2, R611.5.1, R611.6.1, R611.8.2,
R611.9.2, R611.9.3
332—10Code Requirements for Residential Concrete ConstructionR402.2, R403.1, R404.1.2, R404.1.2.4,
R404.1.4.2, R506.1
530—11Building Code Requirements for Masonry Structures R404.1.1, R606.1, R606.1.1,
R606.12.1, R606.12.2.2.2, R606.12.2.3.1,
R606.12.3.1, Table R703.4
530.1—11 Specification for Masonry StructuresR404.1.1, R606.1, R606.1.1, R606.12.1, R606.12.2.2.1,
R606.12.2.2.2, R606.12.3.1, Table R703.4
ACCAAir Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
Title Referenced
in code
section number
Manual D—-09 Residential Duct SystemsM1601.1, M1602.2
Manual J—-11 Residential Load Calculation—Eighth Edition N1103.6, M1401.3
Manual S—-10 Residential Equipment SelectionN1103.6, M1401.3
AFPAAmerican Forest and Paper Association
1111 19th Street, NW, Suite 800
Washington, DC 20036
Standard
reference
number
Title Referenced
in code
section number
AFPA—2012Span Tables for Joists and RaftersR502.3, R802.4, R802.5
ANSI/AF&PA
WFCM—2012
Wood Frame Construction Manual for One- and
Two-family Dwellings
R301.1.1, R301.2.1.1,
R611.9.2, R611.9.3, R611.10
NDS—2012 National Design Specification (NDS) for Wood Construction—
with 2012 Supplement
R404.2.2, R502.2, Table R503.1,
R602.3, Table R602.3.1, R611.9.2, R611.9.3, R802.2
PWF—2007 Permanent Wood Foundation Design SpecificationR401.1, R404.2.3
AISIAmerican Iron and Steel Institute
1140 Connecticut Ave, Suite 705
Washington, DC 20036
Standard
reference
number
Title Referenced
in code
section number
AISI S100—07/S2—10North American Specification for the Design of Cold-formed
Steel Structural Members, with Supplement 2, dated 2010
R505.1.3, R603.6, R611.9.2,
R611.9.3, R804.3.7
AISI S230—07/S2—08Standard for Cold-formed Steel Framing—Prescriptive Method
for One- and Two-family Dwellings, with Supplement 2, dated 2008
R301.1.1, R301.2.1.1, R301.2.2.3.1,
R301.2.2.3.5, R603.6, R603.9.4.1, R603.9.4.2, R611.9.2, R611.9.3, R611.10
AITCAmerican Institute of Timber Construction
7012 S. Revere Parkway, Suite 140
Centennial, CO 80112
Standard
reference
number
Title Referenced
in code
section number
ANSI/AITC A 190.1—07Structural Glued-laminated TimberR502.1.5,R602.1.2,R802.1.4
ANSIAmerican National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A108.1A—99Installation of Ceramic Tile in the Wet-set Method, with Portland Cement MortarR702.4.1
A108.1B—99Installation of Ceramic Tile, Quarry Tile on a Cured
Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar
R702.4.1
A108.4—99Installation of Ceramic Tile with Organic Adhesives or
Water-Cleanable Tile-setting Epoxy Adhesive
R702.4.1
A108.5—99Installation of Ceramic Tile with Dry-set Portland
Cement Mortar or Latex Portland Cement Mortar
R702.4.1
A108.6—99Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting
and -grouting Epoxy
R702.4.1
A108.11—99Interior Installation of Cementitious Backer UnitsR702.4.1
A118.1—99American National Standard Specifications for Dry-set Portland Cement MortarR702.4.1
A118.3—99American National Standard Specifications for Chemical-resistant,
Water-cleanable Tile-setting and -grouting Epoxy, and
Water-cleanable Tile-setting Epoxy Adhesive
R702.4.1
A118.10—99Specification for Load-bearing, Bonded, Waterproof Membranes for
Thin-set Ceramic Tile and Dimension Stone Installation
P2709.2,P2709.2.4
A136.1—99American National Standard Specifications for Organic Adhesives for
Installation of Ceramic Tile
R702.4.1
A137.1—88American National Standard Specifications for Ceramic TileR702.4.1
ANSI/EIMA 99A-01ParticleboardR503.3.1,R605.1
A208.1—2009American National Standard for Exterior Insulation and Finish Systems (EIFS)R703.9.4, GA Amendments
LC1/CSA 6.26—05Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST)G2414.5.3
LC4—07Press-connect Copper and Copper-alloy Fittings for
Use in Fuel Gas Distribution Systems
G2414.10.2
Z21.1—05Household Cooking Gas AppliancesG2447.1
Z21.5.1/CSA 7.1—06Gas Clothes Dryers—Volume I—Type I Clothes DryersG2438.1
Z21.8—94 (R2002)Installation of Domestic Gas Conversion BurnersG2443.1
Z21.10.1/CSA 4.1—09Gas Water Heaters—Volume I—Storage Water Heaters with Input Ratings
of 75,000 Btu per hour or Less
G2448.1
Z21.10.3/CSA 4.3—04Gas Water Heaters—Volume III—Storage Water Heaters with Input Ratings
above 75,000 Btu per hour, Circulating and Instantaneous
G2448.1
Z21.11.2—07Gas-fired Room Heaters—Volume II—Unvented Room HeatersG2445.1
Z21.13/CSA 4.9—10Gas-fired Low-pressure Steam and Hot Water BoilersG2452.1
Z21.15/CSA 9.1—09Manually Operated Gas Valves for Appliances, Appliance
Connector Valves and Hose End Valves
Table G2420.1.1
Z21.22—99 (R2003)Relief Valves for Hot Water Supply Systems—with Addenda Z21.22a—2000 (R2003)
and 21.22b—2001 (R2003)
P2803.2,P2803.7
Z21.24—97Connectors for Gas AppliancesG2422.1
Z21.40.1/
CSA 2.91—96 (R2002)
Gas-fired, Heat-activated Air-conditioning and Heat Pump AppliancesG2449.1
Z21.40.2/
CSA 2.92—96 (R2002)
Gas-fired, Work-activated Air-conditioning and Heat
Pump Appliances (Internal Combustion)
G2449.1
Z21.42—93 (R2002)Gas-fired Illuminating AppliancesG2450.1
Z21.47/CSA 2.3—06Gas-fired Central FurnacesG2442.1
Z21.50/CSA 2.22—07Vented Gas FireplacesG2434.1
Z21.56/CSA 4.7—06Gas-fired Pool HeatersG2441.1
Z21.58—95/CSA 1.6—07Outdoor Cooking Gas AppliancesG2447.1
Z21.60/CSA 2.26—03Decorative Gas Appliances for Installation in Solid Fue-burning FireplacesG2432.1
Z21.75/CSA 6.27—07Connectors for Outdoor Gas AppliancesG2422.1
Z21.80—03Line Pressure RegulatorsG2421.1
Z21.83—98Fuel Cell Power PlantsM1903.1
Z21.84—02Manually Listed, Natural Gas Decorative Gas Appliances for Installation in
Solid Fuel-burning Fireplaces—with Addenda Z21.84a—2003
G2432.1,G2432.2
Z21.86—04Gas-fired Vented Space Heating AppliancesG2436.1,G2437.1,G2446.1
Z21.88—02Vented Gas Fireplace Heaters—with Addenda A21.88a—2003 and Z21.88b—2004G2435.1
Z21.91—01Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room HeatersG2445.7.1
Z21.97—09Outdoor Decorative AppliancesG2454.1
Z4.3-95 (R2005)Nonsewered Waste Disposal SystemsR306.6, GA Amendments
Z83.6—90 (R1998)Gas-fired Infrared HeatersG2451.1
Z83.8—02Gas-fired Unit Heaters and Gas-fired Duct Furnaces—with Addenda Z83.8a—2003G2444.1
Z83.19—01 (R2005)Gas-fuel High-intensity Infrared HeatersG2451.1
Z83.20—08Gas-fired Low-intensity Infared Heaters Outdoor Decorative AppliancesG2451.1
Z97.1—09Safety Glazing Materials Used in Buildings—Safety Performance Specifications
and Methods of Test
R308.1.1,R308.3.1
Z124.1—95Plastic Bathtub Units Table P2701.1
Z124.2—95Plastic Shower Receptors and Shower StallsTableP2701.1
Z124.3—95Plastic Lavatories TableP2701.1,P2711.1,P2711.2
Z124.4—96Plastic Water Closet Bowls and TanksTableP2701.1,P2712.1
Z124.6—97Plastic SinksTableP2701.1
APAAPA—The Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
Standard
reference
number
Title Referenced
in code
section number
ANSI/APA PRP 210—08Standard for Performance-rated Engineered Wood SidingR604.1, TableR703.4
APA E30—03Engineered Wood Construction GuideTableR503.2.1.1(1),R503.2.2,
R803.2.2,R803.2.3
APSPThe Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
ANSI/APSP 7—06Standard for Suction Entrapment Avoidance in Swimming Pools Wading Pools, Spas,
Hot Tubs and Catch Basins
AG106.1
ANSI/NSPI 3—99Standard for Permanently Installed Residential SpasAG104.1
ANSI/NSPI 4—2007Standard for Above-ground/On-ground Residential Swimming PoolsAG103.2
ANSI/NSPI 5—2003Standard for Residential In-ground Swimming PoolsAG103.1
ANSI/NSPI 6—99Standard for Residential Portable SpasAG104.2
ASCE/SEIAmerican Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191
Standard
reference
number
Title Referenced
in code
section number
5—11Building Code Requirements for Masonry StructuresR404.1.1,R606.1,R606.1.1,
R606.12.1,R606.12.2.2.1,R606.12.2.2.2,
R606.12.3.1, Table R703.4
6—11Specification for Masonry StructuresR606.1,R606.1.1,
R606.12.1,R606.12.2.2.1,R606.12.2.2.2,
R606.12.3.1, Table R703.4
7—10Minimum Design Loads for Buildings and Other StructuresR301.2.1.1,R301.2.1.2,
R301.2.1.5,R301.2.1.5.1, Table R611.6(1),
Table R611.6(2), Table R611.6(3),
Table R611.6(4), Table R611.7(1A),R611.9.2,
R611.9.3, TableR802.11, AH107.4.3
24—05 Flood-resistant Design and ConstructionR301.2.4,R301.2.4.1,R322.1,
R322.1.1,R322.1.6,R322.1.9,R322.2.2, R3223.3,AG103.3
32—01 Design and Construction of Frost-protected Shallow FoundationsR403.1.4.1
ASHRAEAmerican Society of Heating, Refrigerating
and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
number
Title Referenced
in code
section number
ASHRAE—2009ASHRAE Handbook of FundamentalsN1102.1.4, Table N1105.5.2(1), P3001.2, P3101.4, P3103.2
ASHRAE 193—2010Method of Test for Determining Air Tightness of HVAC EquipmentN1103.2.2.1
34—2010Designation and Safety Classification of Refrigerants M1411.1
ASMEAmerican Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
ASME/A17.1—2007/
CSA B44—2007
Safety Code for Elevators and Escalators—with A17.1a/CSA B44a—08 AddendaR321.1
A18.1—2008Safety Standard for Platforms and Stairway Chair LiftsR321.2
A112.1.2—2004Air Gaps in Plumbing SystemsTable P2902.3,P2902.3.1
A112.1.3—2000
(Reaffirmed 2005)
Air Gap Fittings for Use with Plumbing Fixtures, Appliances and AppurtenancesTable P2701.1,P2902.3.1
A112.3.1—2007Stainless Steel Drainage Systems for Sanitary, DWV, Storm
and Vacuum Applications Above and Below Ground
Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, Table P3302.1
A112.3.4—2000 (R2004)Macerating Toilet Systems and Related ComponentsTable P2701.1,P3007.5
A112.4.1—1993 (R2002)Water Heater Relief Valve Drain TubesP2803.6.1
A112.4.2—2003 (R2008)Water-closet Personal Hygiene DevicesP2722.5
A112.4.3—1999 (R2004)Plastic Fittings for Connecting Water Closets to the Sanitary Drainage SystemP3003.19
A112.6.1M—1997 (R2002) Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public UseTable P2701.1,P2702.4
A112.6.2—2000 (R2004)Framing-affixed Supports for Off-the-floor Water Closets with Concealed TanksTable P2701.1,P2702.4
A112.6.3—2001 (R2007)Floor and Trench DrainsTable P2701.1
A112.14.1—03
(Reaffirmed 2008)
Backwater ValvesP3008.2
A112.18.1—2005/
CSA B125.1—2010
Plumbing Supply FittingsTable P2701.1,P2708.4, P2708.5,P2722.1,P2902.2
A112.18.2—2005/
CSA B125.2—2005
Plumbing Waste Fittings with 2007 and 2008 SupplementsTable P2701.1,P2702.2
A112.18.3—2002
(Reaffirmed 2008)
Performance Requirements for Backflow Protection Devices and
Systems in Plumbing Fixture Fittings
P2708.4,P2722.3
A112.18.6/
CSA B125.6—2009
Flexible Water ConnectorsP2905.7
A112.19.1M/
CSA B45.2—2008
Enameled Cast-iron and Enameled Steel Plumbing Fixtures Table P2701.1,P2711.1
A112.19.2—2008/
CSA B45.1—2008
Ceramic Plumbing FixturesTable P2701.1,P2705.1,P2711.1,P2712.1,P2712.2,P2712.9
A112.19.3—2008/
CSA B45.4—2008
Stainless Steel Plumbing Fixtures Table P2701.1,P2705.1,P2711.1,P2712.1
A112.19.4M—1994
(R2004)
Porcelain-enameled-formed Steel Plumbing Fixtures—with
1998 and 2000 Supplements
Table P2701.1,P2711.1
A112.19.5/
CSA B45.15—2009
Trim for Water-closet Bowls, Tanks and UrinalsTable P2701.1
A112.19.7/
CSA B45.10—2009
Hydromassage Bathtub AppliancesTable P2701.1
A112.19.12—2006Wall-mounted and Pedestal-mounted, Adjustable
and Pivoting Lavatory and Sink Carrier Systems
Table P2701.1,P2711.4,P2714.2
A112.19.15—2005Bathtub/Whirlpool Bathtubs with Pressure-sealed DoorsTable P2701.1,P2713.2
B1.20.1—1983 (R2006)Pipe Threads, General-purpose (Inch)G2414.9,P3003.3.3,P3003.5.3,
P3003.10.4,P3003.12.1,P3003.14.3
B16.3—2006Malleable-iron-threaded Fittings, Classes 150 and 300Table P2905.6
B16.4—2006Gray-iron-threaded Fittings Classes, 125 and 250Table P2905.6, Table P3002.3
B16.9—2007Factory-made, Wrought-steel Buttwelding FittingsTable P2905.6
B16.11—2005Forged Fittings, Socket-welding and ThreadedTable P2905.6
B16.12—1998Cast-iron-threaded Drainage FittingsTable P2905.6, Table P3002.3 (R2006)
B16.15—2006Cast-bronze-threaded FittingsTable P2905.6, Table P3002.3
B16.18—2001 (R2005) Cast-copper-alloy Solder Joint Pressure FittingsTable P2905.6, Table P3002.3
B16.22—2001(R2005)Wrought-copper and Copper-alloy Solder Joint Pressure FittingsTable P2905.6, Table P3002.3
B16.23—2002 (R2006) Cast-copper-alloy Solder Joint Drainage Fittings (DWV)Table P2905.6, Table P3002.3
B16.26—2006Cast-copper-alloy Fittings for Flared Copper TubesTable P2905.6, Table P3002.3
B16.28—1994Wrought-steel Buttwelding Short Radius Elbows and ReturnsTable P2905.6
B16.29—2007Wrought-copper and Wrought-copper-alloy Solder Joint Drainage Fittings (DWV)Table P2905.6,
Table P3002.3
B16.33—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in Gas Piping
Systems up to 125 psig (Sizes 1/2 through 2)
Table G2420.1.1
B16.44—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in
Above-ground Piping Systems up to 5 psi
Table G2420.1.1
B36.10M—2004Welded and Seamless Wrought-steel PipeG2414.4.2
BPVC—2007ASME Boiler and Pressure Vessel Code (2007 Edition)M2001.1.1,G2452.1
CSD-1—2009Controls and Safety Devices for Automatically Fired BoilersM2001.1.1,G2452.1
ASSEAmerican Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
Standard
reference
number
Title Referenced
in code
section number
1001—2008Performance Requirements for Atmospheric-type Vacuum BreakersTable P2902.3,P2902.3.2
1002—2008Performance Requirements for Anti-siphon Fill Valves for
Water Closet Flush Tank
Table P2701.1, Table P2902.3,P2902.4.1
1003—2009Performance Requirements for Water-pressure-reducing
Valves for Domestic Water Distribution Systems
P2903.3.1
1008—2006 Performance Requirements for Plumbing Aspects of
Residential Food Waste Disposer Units
Table P2701.1
1010—2004Performance Requirements for Water Hammer ArrestersP2903.5
1011—2004Performance Requirements for Hose Connection Vacuum BreakersTable P2902.3,P2902.3.2
1012—2009Performance Requirements for Backflow Preventers
with Intermediate Atmospheric Vent
Table P2902.3,P2902.3.3,P2902.5.1,P2902.5.5
1013—2009Performance Requirements for Reduced Pressure Principle Backflow Preventers
and Reduced Pressure Principle Fire Protection Backflow Preventers
Table P2902.3,P2902.3.5,
P2902.5.1,P2902.5.5
1015—2009Performance Requirements for Double Check Backflow Prevention Assemblies
and Double Check Fire Protection Backflow Prevention Assemblies
Table P2902.3,P2902.3.6
1016—2010Performance Requirements for Automatic Compensating
Valves for Individual Showers and Tub/Shower Combinations
Table P2701.1,P2708.3,P2722.2
1017—2010Performance Requirements for Temperature-actuated Mixing Valves for
Hot Water Distribution Systems
P2724.1,P2802.2
1019—2010Performance Requirements for Freeze-resistant, Wall Hydrants,
Vacuum Breaker, Draining Types
Table P2701.1,P2902.3
1020—2004Performance Requirements for Pressure Vacuum Breaker AssemblyTable P2902.3,P2902.3.4
1023—2010Performance Requirements for Hot Water Dispensers, Household-storage-
type—Electrical
Table P2701.1
1024—2004Performance Requirements for Dual Check Backflow Preventers, Anti-siphon-type,
Residential Applications
Table P2902.3
1035—2008Performance Requirements for Laboratory Faucet Backflow Preventers Table P2902.3,P2902.3.2
1037—2010Performance Requirements for Pressurized Flushing Devices
(Flushometer) for Plumbing Fixtures
Table P2701.1
1047—2009Performance Requirements for Reduced Pressure Detector Fire
Protection Backflow Prevention Assemblies
Table P2902.3,P2902.3.5
1048—2009Performance Requirements for Double Check Detector Fire
Protection Backflow Prevention Assemblies
Table P2902.3,P2902.3.6
1050—2009Performance Requirements for Stack Air Admittance
Valves for Sanitary Drainage Systems
P3114.1
1051—2009Performance Requirements for Individual and Branch-type Air Admittance
Valves for Plumbing Drainage Systems
P3114.1
1052—2004Performance Requirements for Hose Connection Backflow PreventersTable P2701.1,
Table P2902.3,P2902.3.2
1056—2010Performance Requirements for Spill-resistant Vacuum BreakersTable P2902.3,P2902.3.4
1060—2006Performance Requirements for Outdoor Enclosures for Fluid-conveying ComponentsP2902.6.1
1061—2010Performance Requirements for Removable and Nonremovable Push Fit FittingsTable P2905.6
1062—2006Performance Requirements for Temperature-actuated, Flow Reduction (TAFR)
Valves for Individual Supply Fittings
Table P2701.1,P2724.2
1066—2009Performance Requirements for Individual Pressure Balancing In-line
Valves for Individual Fixture Fittings
P2722.4
1070—2004Performance Requirements for Water-temperature-limiting DevicesP2713.3,P2721.2
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
reference
number
Title Referenced
in code
section number
A 36/A 36M—08 Specification for Carbon Structural SteelR606.15, R611.5.2.2
A 53/A 53M—07 Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and SeamlessR402.3,
Table M2101.1, G2414.4.2, Table P2905.4,
Table P2905.5, Table P3002.1(1)
A 74—09Specification for Cast-iron Soil Pipe and FittingsTable P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3005.2.9, Table P3302.1
A 82/A 82M—05aSpecification for Steel Wire, Plain, for Concrete Reinforcement R606.15
A 106/A 106M—08Specification for Seamless Carbon Steel Pipe for High-temperature ServiceTable M2101.1, G2414.4.2
A 153/A 153M—05Specification for Zinc Coating (Hot Dip) on Iron and Steel HardwareR317.3, Table R606.15.1
A 167—99 (2009)Specification for Stainless and Heat-resisting Chromium-nickel
Steel Plate, Sheet and Strip
R606.15, Table R606.15.1
A 240/A 240M—09aStandard Specification for Chromium and Chromium-nickel Stainless
Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications
Table R905.10.3(1)
A 254—97 (2007)Specification for Copper Brazed Steel TubingTable M2101.1, G2414.5.1
A 307—07bSpecification for Carbon Steel Bolts and Studs, 60,000 psi Tensile StrengthR611.5.2.2
A 312/A 312M—08aSpecification for Seamless, Welded and Heavily Cold Worked
Austenitic Stainless Steel Pipes
Table P2905.4, Table P2905.5,
Table P2905.6, P2905.12.2
A 463/A 463M—06 Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip ProcessTable R905.10.3(2)
A 510—08Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon SteelR606.15
A 539—99Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil LinesM2202.1
A 615/A 615M—09Specification for Deformed and Plain Billet-steel Bars for
Concrete Reinforcement
R402.3.1, R404.1.2.3.7.1, R611.5.2.1
A 641/A 641M—09aSpecification for Zinc-coated (Galvanized) Carbon Steel WireTable R606.15.1
A 653/A 653M—08Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron
Alloy-coated Galvanized) by the Hot-dip Process
R317.3.1, R505.2.1,
R505.2.3, R603.2.1, R603.2.3, Table R606.15.1,
R611.5.2.3, R804.2.1, R804.2.3, Table R905.10.3(1),
Table R905.10.3(2), M1601.1.1
A 706/A 706M—09Specification for Low-alloy Steel Deformed and Plain Bars for
Concrete Reinforcement
R402.3.1, R404.1.2.3.7.1, R611.5.2.1
A 755/A 755M—03 (2008)Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and
Prepainted by the Coil-coating Process for Exterior Exposed Building Products
Table R905.10.3(2)
A 778—01Specification for Welded Unannealed Austenitic Stainless Steel Tubular ProductsTable P2905.4,
Table P2905.5, Table P2905.6
A 792/A 792M—08Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the
Hot-dip Process
R505.2.1, R505.2.3, R603.2.1,
R603.2.3, R611.5.2. 3, R804.2.1,
R804.2.3, Table 905.10.3(2)
A 875/A 875M—06Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the
Hot-dip Process
R611.5.2.3, Table R905.10.3(2)
A 888—09Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain,
Waste and Vent Piping Application
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3005.2.9, Table P3302.1
A 924/A 924M—08aStandard Specification for General Requirements for Steel Sheet, Metallic-coated
by the Hot-Dip Process
Table R905.10.3(1)
A 951—06Specification for Steel Wire Masonry Joint Reinforcement R606.15
A 996/A 996M—09Specifications for Rail-steel and Axle-steel Deformed Bars for Concrete ReinforcementTable R404.1.2(9),
R404.1.2.3.7.1,
R611.5.2.1, Table R611.5.4(2)
A 1003/A 1003M—08Standard Specification for Steel Sheet, Carbon, Metallic and
Nonmetallic-coated for Cold-formed Framing Members
R505.2.1, R505.2.3, R603.2.1,
R603.2.3, R804.2.1, R804.2.3
B 32—08Specification for Solder MetalP3003.10.3, P3003.11.3
B 42—02e01Specification for Seamless Copper Pipe, Standard SizesTable M2101.1, Table P2905.4,
Table P2905.5, Table P3002.1(1)
B 43—98 (2004)Specification for Seamless Red Brass Pipe, Standard SizesTable M2101.1, G2413.5.2,
Table P2905.4, Table P3002.1(1)
B 75—02Specification for Seamless Copper TubeTable M2101.1, Table P2905.4, Table P2905.5,
Table P3002.1(1), Table P3002.1(2), Table P3002.2
B 88—03Specification for Seamless Copper Water TubeTable M2101.1, G2414.5.2, Table, P2905.4,
Table P2905.5, Table P3002.1(1),
Table P3002.1(2), Table P3002.2
B 101—07Specification for Lead-coated Copper Sheet and Strip for Building ConstructionTable R905.2.8.2,
Table R905.10.3(1)
B 135—08aSpecification for Seamless Brass TubeTable M2101.1
B 209—07Specification for Aluminum and Aluminum-alloy Sheet and PlateTable 905.10.3(1)
B 227—04Specification for Hard-drawn Copper-clad Steel WireR606.15
B 251—02e01Specification for General Requirements for Wrought Seamless Copper and
Copper-alloy Tube
Table M2101.1, Table P2905.4,
Table P2905.5, Table P3002.1(1), Table P3002.2
B 302—07 Specification for Threadless Copper Pipe, Standard SizesTable M2101.1, Table P2905.4,
Table P2905.5, Table P3002.1(1)
B 306—09 Specification for Copper Drainage Tube (DWV) Table M2101.1, Table P3002.1(1),
Table P3002.1(2), Table P3002.2
B 370—09 Specification for Copper Sheet and Strip for Building ConstructionTable R905.2.8.2,
Table R905.10.3(1), Table P2701.1
B 447—07 Specification for Welded Copper Tube Table P2904.4, Table P2905.5
B 695—04Standard Specification for Coatings of Zinc Mechanically Deposited on
Iron and Steel
R317.3.1, R317.3.3
B 813—00 (2009)Specification for Liquid and Paste Fluxes for Soldering Applications
of Copper and Copper Alloy Tube
Table M2101.1, P2905.14,
P3003.10.3, P3003.11.3
B 828—02 Practice for Making Capillary Joints by Soldering of Copper and
Copper Alloy Tube and Fittings
P2905.14, P3003.10.3, P3003.11.3
C 4—04e01Specification for Clay Drain Tile and Perforated Clay Drain TileTable P3302.1
C 5—03 Specification for Quicklime for Structural PurposesR702.2.1
C 14—07 Specification for Non-reinforced Concrete Sewer,
Storm Drain and Culvert Pipe
Table P3002.2
C 22/C 22M—00
(2005e01)
Specification for GypsumR702.2.1, R702.3.1
C27—98 (2008)Specification for Standard Classification of Fireclay
and High-alumina Refractory Brick
R1001.5, R1001.8
C 28/C 28M—00 (2005)Specification for Gypsum Plasters R702.2.1
C 33/C 33M—08 Specification for Concrete AggregatesR403.4.1
C 34—03 Specification for Structural Clay Load-bearing Wall Tile Table R301.2(1)
C 35—01(2005) Specification for Inorganic Aggregates for Use in Gypsum Plaster R702.2.1
C 55—06e01Specification for Concrete Building BrickR202, Table R301.2(1)
C 59/C 59M—00 (2006) Specification for Gypsum Casting and Molding PlasterR702.2
C 61/C 61M—00 (2006)Specification for Gypsum Keene's CementR702.2.1
C 62—08 Specification for Building Brick (Solid Masonry
Units Made from Clay or Shale)
R202, Table R301.2(1)
C 73—05Specification for Calcium Silicate Face Brick (Sand Lime Brick)R202, Table R301.2(1)
C 76—08aSpecification for Reinforced Concrete Culvert, Storm
Drain and Sewer Pipe
Table P3002.2
C 90—08 Specification for Load-bearing Concrete Masonry UnitsTable R301.2(1)
C 91—05 Specification for Masonry CementR702.2.2
C 94/C 94M—09 Specification for Ready-mixed ConcreteR404.1.2.3.2, R611.5.1.1
C 129—06 Specification for Nonload-bearing Concrete Masonry UnitsTable R301.2(1)
C 143/C 143M—08Test Method for Slump or Hydraulic Cement ConcreteR404.1.2.3.4, R611.5.1.3, R611.6.1
C 145—85 Specification for Solid Load-bearing Concrete Masonry UnitsR202, Table R301.2(1)
C 150—07Specification for Portland CementR702.2.2
C 199—84 (2005)Test Method for Pier Test for Refractory Mortar R1001.5, R1001.8, R1003.12
C 203—05a Standard Test Methods for Breaking Load and Flexural
Properties of Block-type Thermal Insulation
Table R613.3.1
C 207—06Specification for Hydrated Lime for Masonry PurposesTable R607.1
C 208—08aSpecification for Cellulosic Fiber Insulating BoardTable R602.3(1), Table R906.2
C 216—07aSpecification for Facing Brick (Solid Masonry Units
Made from Clay or Shale)
R202, Table R301.2(1)
C 270—08a Specification for Mortar for Unit MasonryR607.1, AE602
C 272—01(2007) Standard Test Method for Water Absorption of Core Materials for
Structural Sandwich Constructions
Table R613.3.1
C 273/C 273M—07aStandard Test Method for Shear Properties of Sandwich Core Materials Table R613.3.1
C 296—00 (2004) Specification for Asbestos Cement Pressure PipeTable P2905.4
C 315—07Specification for Clay Flue Liners and Chimney Pots R1001.8, R1003.11.1,
Table R1003.14(1), G2425.12
C 406—06e01Specifications for Roofing SlateR905.6.4
C 411—05Test Method for Hot-surface Performance of High-temperature Thermal InsulationM1601.3
C 425—04 Specification for Compression Joints for Vitrified Clay Pipe and FittingsTable P3002.2, P3003.15, P3003.18
C 428—05 (2006)Specification for Asbestos-cement Nonpressure Sewer Pipe Table P3002.2
C 443—05aSpecification for Joints for Concrete Pipe and Manholes, Using Rubber GasketsP3003.7, P3003.18
C 475/C 475—02 (2007)Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard R702.3.1
C 476—08 Specification for Grout for Masonry R609.1.1
C 508—04 Specification for Asbestos-cement Underdrain PipeTable P3302.1
C 514—04Specification for Nails for the Application of Gypsum WallboardR702.3.1
C 552—07Standard Specification for Cellular Glass Thermal Insulation Table R906.2
C 557—03e01Specification for Adhesives for Fastening Gypsum Wallboard to Wood FramingR702.3.1
C 564—08 Specification for Rubber Gaskets for Cast Iron Soil Pipe and FittingsP3003.6.2, P3003.6.3, P3003.18
C 578—08b Specification for Rigid, Cellular Polystyrene Thermal InsulationR403.3, R613.3.1,
R703.11.2.1, Table R906.2
C 587—04Specification for Gypsum Veneer Plaster R702.2.1
C 595—08aSpecification for Blended Hydraulic CementsR702.2.2
C 631—09Specification for Bonding Compounds for Interior Gypsum Plastering R702.2.1
C 645—08aSpecification for Nonstructural Steel Framing Members R702.3.3
C 652—09Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)R202, Table R301.2(1)
C 685/C 685M—07Specification for Concrete Made by Volumetric
Batching and Continuous Mixing
R404.1.2.3.2, R611.5.1.1
C 700—07a Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength and PerforatedTable P3002.2, Table P3002.3, Table P3302.1
C 728—05Standard Specification for Perlite Thermal Insulation Board Table R906.2
C 836—06 Specification for High Solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane for Use with Separate Wearing Course
R905.15.2
C 843—99 (2006) Specification for Application of Gypsum Veneer PlasterR702.2.1
C 844—04 Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster R702.2.1
C 847—09 Specification for Metal LathR702.2.1, R702.2.2
C 887—05Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar R406.1
C 897—05 Specification for Aggregate for Job-mixed Portland Cement-based PlastersR702.2.2
C 920—08 Standard Specification for Elastomeric Joint SealantsR406.4.1
C 926—06 Specification for Application of Portland Cement-based Plaster R702.2.2, R702.2.2.1, R703.6,
R703.6.2.1, R703.6.4
C 933—07bSpecification for Welded Wire LathR702.2.1, R702.2.2
C 954—07 Specification for Steel Drill Screws for the Application of Gypsum Panel
Products or Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or to 0.112 in. (2.84 mm) in Thickness
R505.2.4, R603.2.4, R702.3.6, R804.2.4
C 955—09 Specification for Load-bearing (Transverse and Axial) Steel Studs, Runners (Tracks), and Bracing or Bridging for Screw Application of Gypsum Panel Products and Metal Plaster BasesR702.3.3
C 957—06 Specification for High-solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane for Use with Integral Wearing Surface
R905.15.2
C 1002—07Specification for Steel Drill Screws for the Application of Gypsum Panel Products
or Metal Plaster Bases
R702.3.1, R702.3.6
C 1029—08Specification for Spray-applied Rigid Cellular Polyurethane Thermal InsulationR905.14.2
C 1032—06 Specification for Woven Wire Plaster Base R702.2.1, R702.2.2
C 1047—09 Specification for Accessories for Gypsum Wallboard
and Gypsum Veneer Base
R702.2.1, R702.2.2, R702.3.1
C 1063—08 Specification for Installation of Lathing and Furring to Receive Interior and
Exterior Portland Cement-based Plaster
R702.2.2, R703.6
C 1107/C 1107M—08 Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink)R402.3.1
C 1116/C 116M—08a Standard Specification for Fiber-reinforced Concrete and ShotcreteR402.3.1
C 1167—03Specification for Clay Roof TilesR905.3.4
C 1173—08 Specification for Flexible Transition Couplings for Underground
Piping Systems
P3003.3, P3003.7, P3003.8.1,
P3003.14.1, P3003.15, P3003.17.2, P3003.18
C 1177/C 1177M—08Specification for Glass Mat Gypsum Substrate for Use as Sheathing R702.3.1
C 1178/C 1178M—08Specification for Glass Mat Water-resistant Gypsum Backing PanelR702.3.1, R702.3.8, R702.4.2
C 1186—08Specification for Flat Nonasbestos Fiber Cement SheetsR703.10.1, R703.10.2
C 1193-11a Standard Guide for Use of Joint Sealants Standard Practice for Application of Class PB Exterior Insulation and Finish Systems Table R703.4, GA Amendments, R703.9.4, GA Amendments
C 1261—07 Specification for Firebox Brick for Residential Fireplaces R1001.5, R1001.8
C 1277—08 Specification for Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings P3003.6.3
C 1278/C 1278M—07a Specification for Fiber-reinforced Gypsum PanelsR702.3.1, R702.3.8, R702.4.2
C 1283—07a Practice for Installing Clay Flue Lining R1003.9.1, R1003.12
C 1288—99 (2004)e1Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate SheetsR702.4.2
C 1289—08Standard Specification for Faced Rigid Cellular Polyisocyanurate
Thermal Insulation Board
R703.11.2.1, Table R906.2
C 1325—08bStandard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate SheetsR702.4.2
C 1328—05Specification for Plastic (Stucco) CementR702.2.2
C 1396/C 1396M—06aSpecification for Gypsum Board Table R602.3(1), R702.2.1, R702.2.2, R702.3.1, R702.3.8
C 1397-09Standard Practice for Application of Class PB Exterior Insulation and Finish Systems R703.9.4, GA Amendments
C 1440—08Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain,
Waste and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
P3003.18
C 1460—08 Specification for Shielded Transition Couplings for Use with Dissimilar
DWV Pipe and Fittings Above Ground
P3003.18
C 1461—08 Specification for Mechanical Couplings Using Thermoplastic
Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary
and Storm Plumbing Systems for Above and Below Ground Use
P3003.18
C 1492—03 Specification for Concrete Roof Tile R905.3.5
C 1513—04Standard Specification for Steel Tapping Screws for Cold-formed
Steel Framing Connections
R505.2.4, R603.2.4, R702.3.6, R804.2.4
C 1535-05Standard Practice for Application of Exterior Insulation Finish Systems Class PI R703.9.4, GA Amendments
C 1658/C 1658M—06Standard Specification for Glass Mat Gypsum PanelsR702.3.1
D 41—05 Specification for Asphalt Primer Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2, Table R905.11.2
D 43—00(2006)Specification for Coal Tar Primer Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2
D 225—07Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules R905.2.4
D 226—06Specification for Asphalt-saturated (Organic Felt) Used in Roofing and WaterproofingR703.2, R905.2.3,
R905.3.3, R905.4.3, R905.4.3.2,
R905.5.3, R905.5.3.2, R905.6.3,
R905.6.3.2, R905.7.3, R905.8.3, R905.8.3.2,
R905.8.4, Table R905.9.2, R905.10.5.1
D 227—03Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing Table R905.9.2
D 312—00 (2006)Specification for Asphalt Used in RoofingTable R905.9.2
D 422—63 (2007) Test Method for Particle-size Analysis of SoilsR403.1.8.1
D 449—03 (2008) Specification for Asphalt Used in Dampproofing and Waterproofing R406.2
D 450—07Specification for Coal-tar Pitch Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2
D 1227—95 (2007)Specification for Emulsified Asphalt Used as a Protective
Coating for Roofing
Table R905.9.2, Table R905.11.2, R905.15.2
D 1248—05Specification for Polyethylene Plastics Extrusion Materials for Wire and CableM1601.1.2
D 1527—99 (2005) Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe,
Schedules 40 and 80
Table P2905.4
D 1621—04aStandard Test Method for Compressive Properties of Rigid Cellular PlasticsTable R613.3.1
D 1622—08Standard Test Method for Apparent Density of Rigid Cellular PlasticsTable R613.3.1
D 1623—03 Standard Test Method for Tensile and Tensile Adhesion
Properties of Rigid Cellular Plastics
Table R613.3.1
D 1693—08Test Method for Environmental Stress-cracking of Ethylene Plastics Table M2101.1
D 1784—08Standard Specification for Rigid Poly (Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds
M1601.1.2
D 1785—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe,
Schedules 40, 80 and 120
Table P2905.4
D 1863—05 Specification for Mineral Aggregate Used in Built-up RoofsTable R905.9.2
D 1869—95 (2005)e1Specification for Rubber Rings for Asbestos-cement Pipe P2904.17, P3003.4, P3003.18
D 1970—09Specification for Self-adhering Polymer Modified Bitumen
Sheet Materials Used as Steep Roofing Underlayment for
Ice Dam Protection
R905.2.3, R905.2.7.2, R905.2.8.2,
R905.3.3.3, R905.4.3, R905.4.3.2, R905.5.3.2,
R905.6.3.2, R905.7.3.2, R905.8.3.2, R905.10.5.1
D 2104—03 Specification for Polyethylene (PE) Plastic Pipe, Schedule 40 Table P2905.4
D 2126—04Standard Test Method for Response of Rigid Cellular Plastics
to Thermal and Humid Aging
Table R613.3.1
D 2178—04 Specification for Asphalt Glass Felt Used in Roofing and WaterproofingTable R905.9.2
D 2235—04Specification for Solvent Cement for Acrylonitrile-butadiene-styrene
(ABS) Plastic Pipe and Fittings
P2905.9.1.1, P3003.3.2, P3003.8.2
D 2239—03 Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on
Controlled Inside Diameter
Table P2905.4
D 2241—05 Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated
Pipe (SDR-Series)
Table P2905.4
D 2282—05 Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (SDR-PR)Table P2905.4
D 2412—02 (2008) Test Method for Determination of External Loading Characteristics of
Plastic Pipe by Parallel-plate Loading
M1601.1.2
D 2447—03 Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80,
Based on Outside Diameter
Table M2101.1
D 2464—06 Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic
Pipe Fittings, Schedule 80
Table P2905.6
D 2466—06Specification for Poly (Vinyl Chloride) (PVC) Plastic
Pipe Fittings, Schedule 40
Table P2905.6
D 2467—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic
Pipe Fittings, Schedule 80
Table P2905.6
D 2468—96aSpecification for Acrylonitrile-butadiene-styrene (ABS)
Plastic Pipe Fittings, Schedule 40
Table P2905.6
D 2513—08bSpecification for Thermoplastic Gas Pressure Pipe,
Tubing and Fittings
Table M2101.1, M2104.2.1.3,
G2414.6, G2414.6.1, G2414.11, G2415.15.2
D 2559—04Standard Specification for Adhesives for Structural Laminated Wood
Products for Use Under Exterior (West Use) Exposure Conditions
R613.3.3
D 2564—04e01Specification for Solvent Cements for Poly (Vinyl Chloride)
(PVC) Plastic Piping Systems
P2905.9.1.3, Table P3002.2,
P3003.9.2, P3003.14.2
D 2609—02 (2008)Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe Table P2905.6
D 2626—04 Specification for Asphalt-saturated and Coated Organic Felt Base
Sheet Used in Roofing
R905.3.3, Table R905.9.2
D 2657—07 Standard Practice for Heat Fusion-joining of Polyolefin Pipe FittingsP2905.3.1, P3003.17.1
D 2661—08 Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic
Drain, Waste, and Vent Pipe and Fittings
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.3.2, P3003.8.2
D 2665—09 Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain,
Waste and Vent Pipe and Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3
D 2672—96a (2003)Specification for Joints for IPS PVC Pipe Using Solvent CementTable P2905.4
D 2683—04 Specification for Socket-type Polyethylene Fittings for Outside
Diameter-controlled Polyethylene Pipe and Tubing
Table M2101.1, M2104.2.1.1
D 2729—03 Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and FittingsP3009.14.10, Table P3302.1,
Table AO103.10
D 2737—03Specification for Polyethylene (PE) Plastic TubingTable P2905.4
D 2751—05Specification for Acrylonitrile-butadiene-styrene (ABS) Sewer Pipe and FittingsTable P3002.2,
Table P3002.3
D 2822—05Specification for Asphalt Roof Cement, Asbestos ContainingTable R905.9.2
D 2823—05 Specification for Asphalt Roof Coatings, Asbestos ContainingTable R905.9.2
D 2824—06 Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered,
Asbestos Fibered and Fibered without Asbestos
Table R905.9.2, Table R905.11.2
D 2837—08Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe
Materials or Pressure Design Basis for Thermoplastic Pipe Products
Table M2101.1
D 2846/D 2846M—09Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Hot- and Cold-water Distribution Systems
Table M2101.1, P2904.9.1.2,
Table P2905.4, Table P2905.5, Table P2905.6
D 2855—96 (2002)Standard Practice for Making Solvent-cemented Joints
with Poly (Vinyl Chloride) (PVC) Pipe and Fittings
P3003.9.2, P3003.14.2
D 2898—04Test Methods for Accelerated Weathering of Fire-retardant-treated
Wood for Fire Testing
R802.1.3.4, R802.1.3.6
D 2949—01a (2008) Specification for 3.25-in. Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain,
Waste and Vent Pipe and Fittings
Table P3002.1(1),
Table P3002.1(2), Table P3002.2, Table P3002.3
D 3019—08Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered,
Asbestos Fibered and Nonasbestos Fibered
Table R905.9.2, Table R905.11.2
D 3034—08 Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and FittingsTable P3002.2,
Table P3002.3
D 3035—08 Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based On
Controlled Outside Diameter
Table M2101.1
D 3161—09Test Method for Wind Resistance of Asphalt Shingles (Fan Induced Method) R905.2.4.1,Table R905.2.4.1(2), R905.16.3
D 3201—08a Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base ProductsR802.1.3.7
D 3212—07Specification for Joints for Drain and Sewer Plastic Pipes
Using Flexible Elastomeric Seals
P3003.3.1, P3003.8.1, P3003.9.1,
P3003.14.1, P3003.17.2
D 3309—96a (2002)Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution SystemTable M2101.1
D 3311—08 Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns P3002.3
D 3350—08Specification for Polyethylene Plastic Pipe and Fitting Materials Table M2101.1
D 3462—09 Specification for Asphalt Shingles Made From Glass Felt and
Surfaced with Mineral Granules
R905.2.4
D 3468—99 (2006)e01Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene
Used in Roofing and Waterproofing
R905.15.2
D 3679—09 Specification for Rigid Poly (Vinyl Chloride) (PVC) SidingTable R703.4, R703.11
D 3737—08Practice for Establishing Allowable Properties for Structural Glued
Laminated Timber (Glulam)
R502.1.5, R602.1.2, R802.1.4
D 3747—79 (2007)Specification for Emulsified Asphalt Adhesive for Adhering Roof InsulationTable R905.9.2,
Table R905.11.2
D 3909—97b (2004)e1Specification for Asphalt Roll Roofing (Glass Felt)
Surfaced with Mineral Granules
R905.2.8.2, R905.5.4, Table R905.9.2
D 3957—06Standard Practices for Establishing Stress Grades for Structural
Members Used in Log Buildings
R502.1.6, R602.1.3, R802.1.5
D 4022—07Specification for Coal Tar Roof Cement, Asbestos ContainingTable R905.9.2
D 4068—01Specification for Chlorinated Polyethylene (CPE)
Sheeting for Concealed Water Containment Membrane
P2709.2, P2709.2.2
D 4318—05Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils R403.1.8.1
D 4434/D 4434M—09Specification for Poly (Vinyl Chloride) Sheet RoofingR905.13.2
D 4479—07Specification for Asphalt Roof Coatings-asbestos-freeTable R905.9.2
D 4551—96 (2008)e1 Specification for Poly (Vinyl) Chloride (PVC) Plastic Flexible
Concealed Water-containment Membrane
P2709.2, P2709.2.1
D 4586—07 Specification for Asphalt Roof Cement-asbestos-free Table R905.9.2
D 4601—08 Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table R905.9.2
D 4637—08Specification for EPDM Sheet Used in Single-ply Roof MembraneR905.12.2
D 4829—08aTest Method for Expansion Index of SoilsR403.1.8.1
D 4869—05e01 Specification for Asphalt-saturated (Organic Felt) Underlayment
Used in Steep Slope Roofing
R905.2.3, R905.2.7.2, R905.4.3, R905.4.3.2,
R905.5.3, R905.5.3.2, R905.6.3, R905.6.3.2,
R905.7.3, R905.7.3.2, R905.8.3, R905.8.3.2
D 4897—01Specification for Asphalt Coated Glass-fiber Venting
Base Sheet Used in Roofing
Table R905.9.2
D 4990—97a (2005)e01 Specification for Coal Tar Glass Felt Used in Roofing and WaterproofingTable R905.9.2
D 5019—07a Specification for Reinforced Nonvulcanized Polymeric
Sheet Used in Roofing Membrane
R905.12.2
D 5055—09 Specification for Establishing and Monitoring Structural
Capacities of Prefabricated Wood I-joists
R502.1.4
D 5456—09 Standard Specification for Evaluation of Structural
Composite Lumber Products
R502.1.8, R602.14, R802.1.6
D 5516—03Test Method for Evaluating the Flexural Properties of Fire-retardant-treated
Softwood Plywood Exposed to the Elevated Temperatures
R802.1.3.5.1
D 5643—06Specification for Coal Tar Roof Cement Asbestos-freeTable R905.9.2
D 5664—08Test Methods For Evaluating the Effects of Fire-retardant Treatments and Elevated
Temperatures on Strength Properties of Fire-retardant-treated Lumber
R802.1.3.5.2
D 5665—99a (2006)Specification for Thermoplastic Fabrics Used in Cold-applied
Roofing and Waterproofing
Table R905.9.2
D 5726—98 (2005)Specification for Thermoplastic Fabrics Used in Hot-applied
Roofing and Waterproofing
Table R905.9.2
D 6083—05e01 Specification for Liquid-applied Acrylic Coating Used in RoofingTable R905.9.2, Table R905.11.2,
Table R905.14.3, R905.15.2
D 6162—00a (2008)Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet
Materials Using a Combination of Polyester and Glass Fiber Reinforcements
Table R905.11.2
D 6163—00 (2008) Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet
Materials Using Glass Fiber Reinforcements
Table R905.11.2
D 6164—05e1Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous
Sheet Materials Using Polyester Reinforcements
Table R905.11.2
D 6222—08Specification for Atactic Polypropylene (APP) Modified Bituminous
Sheet Materials Using Polyester Reinforcements.
Table R905.11.2
D 6223—02 Specification for Atactic Polypropylene (APP) Modified Bituminous
Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcement
Table R905.11.2
D 6298—05e1Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS)
Modified Bituminous Sheets with a Factory Applied Metal Surface
Table R905.11.2
D 6305—08Practice for Calculating Bending Strength Design Adjustment Factors for
Fire-retardant-treated Plywood Roof Sheathing
R802.1.3.5.1
D 6380—03 (2009)Standard Specification for Asphalt Roll Roofing (Organic Felt) R905.2.8.2, R905.3.3,
R905.5.4
D 6694—08Standard Specification for Liquid-applied Silicone Coating Used in Spray
Polyurethane Foam Roofing Systems
Table R905.14.3, R905.15.2
D 6754—02 Standard Specification for Ketone-ethylene-ester-based Sheet RoofingR905.13.2
D 6757—07Standard Specification for Inorganic Underlayment for
Use with Steep Slope Roofing Products
R905.2.3, R905.2.7.2
D 6841—08Standard Practice for Calculating Design Value Treatment Adjustment
Factors for Fire-retardant-treated Lumber
R802.1.3.5.2
D 6878—08e1Standard Specification for Thermoplastic-polyolefin-based Sheet Roofing R905.13.2
D 6947—07 Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating
Used in Spray Polyurethane Foam Roofing System
Table R905.14.3, R905.15.2
D 7032—08Standard Specification for Establishing Performance Ratings for Wood-plastic
Composite Deck Boards and Guardrail Systems (Guards or Handrails)
R317.4, R317.4.1, R507.3
D 7158—08dStandard Test Method for Wind Resistance of Sealed Asphalt Shingles
(Uplift Force/Uplift Resistance Method)
R905.2.4.1,
Table R905.2.4.1(1)
E 84—09Test Method for Surface Burning Characteristics of Building MaterialsR202, R302.9.3, R302.9.4,
R302.10.1, R302.10.2, R316.3,
R316.4, R316.5.9, R316.5.11,
R802.1.3, M1601.3, M1601.5.2
E 90—04 Test Method for Laboratory Measurement of Airborne
Sound Transmission Loss of Building Partitions and Elements
AK102, AK102.1.1
E 96/E 96M—05 Test Method for Water Vapor Transmission of MaterialsR202, Table R613.3.1,
M1411.5, M1601.4.5
E 108—07aTest Methods for Fire Tests of Roof Coverings R902.1
E 119—08aTest Methods for Fire Tests of Building Construction and Materials R302.2, R302.3,
R302.4.1, R316.4
E 136—09Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°CR202, Table R302.1(1),
Table R302.1(2), R302.11
E 283—04Test Method for Determining the Rate of Air Leakage Through Exterior
Windows, Curtain Walls and Doors Under Specified Pressure
Differences Across the Specimen
N1102.4.4
E 330—02Test Method for Structural Performance of Exterior Windows,
Curtain Walls and Doors by Uniform Static Air Pressure Difference
R612.4, R612.5, R703.1.2
E 331—00 (2009)Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain
Walls by Uniform Static Air Pressure Difference
R703.1.1
E 492—09Specification for Laboratory Measurement of Impact Sound Transmission
through Floor-ceiling Assemblies Using the Tapping Machine
AK103
E 814—08b Test Method for Fire Tests of Through-penetration FirestopsR302.4.1.2
E 970—08a Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation
Using a Radiant Heat Energy Source
R302.10.5
E 1509—04 Standard Specification for Room Heaters, Pellet Fuel-burning TypeM1410.1
E 1602—03Guide for Construction of Solid Fuel Burning Masonry HeatersR1002.2
E 1886—05 Test Method for Performance of Exterior Windows, Curtain Walls, Doors
and Storm Shutters Impacted by Missles and Exposed
to Cyclic Pressure Differentials
R301.2.1.2, R612.6.1
E 1996—09Standard Specification for Performance of Exterior Windows, Curtain
Walls, Doors and Impact Protective Systems Impacted by
Windborne Debris in Hurricanes
R301.2.1.2, R612.6.1
E 2178—03 Standard Test Method for Air Permeance of Building MaterialsR202
E 2231—04Standard Practice for Specimen Preparation and Mounting of Pipe and
Duct Insulation Materials to Assess Surface Burning Characteristics
M1601.3
E 2273—03 Standard Test Method for Determining the Drainage Efficiency of Exterior
Insulation and Finish Systems (EIFS) Clad Wall Assemblies
R703.9.2
E 2568—09e1 Standard Specification for PB Exterior Insulation and Finish Systems (EIFS)R703.9.1, R703.9.2
E 2570—07Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings
Used Under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
R703.9.2.1
E 2634—08 Standard Specification for Flat Wall Insulating Concrete Form (ICF) SystemsR404.1.2.3.6.1, R611.4.4
F 405—05 Specification for Corrugated Polyethylene (PE) Pipe and FittingsTable P3009.14.10, Table P3302.1,
Table AO103.10
F 409—02(2008)Specification for Thermoplastic Accessible and Replaceable Plastic Tube and
Tubular Fittings
Table P2701.1,
P2702.2, P2702.3
F 437—06Specification for Threaded Chlorinated Poly (Vinyl Chloride)
(CPVC) Plastic Pipe Fittings, Schedule 80
Table P2905.6
F 438—04 Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 40
Table P2905.6
F 439—06 Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
Table P2905.6
F 441/F 441M—02 (2008) Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe, Schedules 40 and 80
Table P2905.4, Table P2905.5
F 442/F 442M—99
(2005)e1
Specification for Chlorinated Poly (Vinyl Chloride)
(CPVC) Plastic Pipe (SDR-PR)
Table P2905.4, Table P2905.5
F 477—08 Specification for Elastomeric Seals (Gaskets) for Joining Plastic PipeP2905.17, P3003.18
F 493—04 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride)
(CPVC) Plastic Pipe and Fittings
P2905.9.1.2
F 628—08Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain,
Waste and Vent Pipe with a Cellular Core
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.3.2, P3003.8.2
F 656—08 Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride)
(PVC) Plastic Pipe and Fittings
P2905.9.1.3,
P3003.9.2, P3003.14.2
F 714—08 Specification for Polyethylene (PE) Plastic Pipe (SDR-PR)
Based on Outside Diameter
Table P3002.2
F 876—08bSpecification for Cross-linked Polyethylene (PEX) Tubing Table M2101.1, Table P2905.4,
Table P2905.5
F 877—07Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and
Cold-water Distribution Systems
Table M2101.1,
Table P2905.4, Table P2905.5, Table P2905.6
F 891—07 Specification for Coextruded Poly (Vinyl Chloride)
(PVC) Plastic Pipe with a Cellular Core
P2905.6, Table P3002.1(1),
Table P3002.1(2), Table P3002.2, Table P3302.1
F 1055—98 (2006)Specification for Electrofusion Type Polyethylene Fittings for Outside
Diameter Controlled Polyethylene Pipe and Tubing
Table M2101.1, M2104.2.1.2
F 1281—07 Specification for Cross-linked Polyethylene/Aluminum/Cross-linked
Polyethylene (PEX-AL-PEX) Pressure Pipe
Table M2101.1, Table P2905.4,
Table P2905.5, Table P2905.6, P2505.11.1
F 1282—06 Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe
Table M2101.1,
Table P2905.4, Table P2905.5,
Table P2905.6, P2905.11.1
F 1346—91 (2003) Performance Specification for Safety Covers and Labeling Requirements for
All Covers for Swimming Pools, Spas and Hot Tubs
AG105.2, AG105.5
F 1412—09Specification for Polyolefin Pipe and Fittings for Corrosive
Waste Drainage
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.16.1
F 1488—03Specification for Coextruded Composite Pipe Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3009.14.10, Table AO103.10
F 1554—07aSpecification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield Strength R611.5.2.2
F 1667—05 Specification for Driven Fasteners, Nails, Spikes and StaplesTable R703.4, R905.2.5
F 1807—08Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring
for SDR9 Cross-linked Polyethylene (PEX) Tubing
Table M2101.1, Table P2905.6
F 1866—07Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and
DWV Fabricated Fittings
Table P3002.3
F 1960—09 Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with
Cross-linked Polyethylene (PEX) Tubing
Table M2101.1, Table P2905.6
F 1973—08 Standard Specification for Factory Assembled Anodeless Risers and Transition
Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution Systems
G2415.15.2
F 1974—08 Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and
Cross-linked Polyethylene/Aluminum/Cross-linked
Polyethylene Composite Pressure Pipe
P2505.11.1, Table P2905.6
F 1986—01 (2006) Multilayer Pipe Type 2, Compression Joints for Hot and Cold Drinking Water SystemsTable P2905.4,
Table P2905.5, Table P2905.6
F 2080—08Specification for Cold-expansion Fittings with Metal Compression-sleeves
for Cross-linked Polyethylene (PEX) Pipe
P2905.6
F 2090—08 Specification for Window Fall Prevention Devices—with Emergency
Escape (Egress) Release Mechanisms
R612.2, R612.3
F 2098—08Standard Specification for Stainless Steel Clamps for SDR9 PEX
Tubing to Metal Insert Fittings
Table M2101.1, Table P2905.6
F 2159—08 Standard Specification for Plastic Insert Fittings Utilizing a
Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing
P2905.6
F 2200—05 Standard Specification for Automated Vehicular Gate ConstructionAR103.1
F 2262—05 Standard Specification for Cross-linked Polyethylene/Aluminum/Cross-linked
Polyethylene Tubing OD Controlled SDR9
Table P2905.4, Table P2905.5
F 2389—07e1Standard for Pressure-rated Polypropylene (PP) Piping SystemsTable M2101.1,
Table P2905.4, Table P2905.5,
Table P2905.6, P2905.10.1
F 2434—08Standard Specification for Metal Insert Fittings Utilizing a Copper
Crimp Ring for Polyethylene/Aluminum/Cross-linked
Polyethylene (PEX-AL-PEX) Tubing
Table P2905.6
F 2623—08Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDRG Tubing Table M2101.1
F 2735—09Standard Specification for SDR9 Cross-linked Polyethylene (PEX) and
Raised Temperature (PE-RT) Tubing
Table M2101.1, Table P2905.6
F 2769—09Polyethylene or Raised Temperature (PE-RT) Plastic Hot and
Cold-Water Tubing and Distribution Systems
Table M2101.1, Table P2905.4
AWPAAmerican Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
Standard
reference
number
Title Referenced
in code
section number
C1—03 All Timber Products—Preservative Treatment by Pressure ProcessesR902.2
M4—08 Standard for the Care of Preservative-treated Wood ProductsR317.1.1, R318.1.2
U1—11 USE CATEGORY SYSTEM: User Specification for Treated Wood
Except Section 6 Commodity Specification H
R317.1, R322.1.8, R402.1.2,
R504.3, Table R905.8.5
AWSAmerican Welding Society
550 N. W. LeJeune Road
Miami, FL 33126
Standard
reference
number
Title Referenced
in code
section number
A5.8—04Specifications for Filler Metals for Brazing and Braze WeldingP3003.5.1, P3003.10.1, P3003.11.1
AWWAAmerican Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
Title Referenced
in code
section number
C104—98Standard for Cement-mortar Lining for Ductile-iron Pipe and Fittings for WaterP2905.4
C110/A21.10—03 Standard for Ductile-iron and Gray-iron Fittings, 3 Inches through 48 Inches, for WaterTable P2905.6,
Table P3002.3
C115/A21.15—99 Standard for Flanged Ductile-iron Pipe with Ductile-iron or
Gray-iron Threaded Flanges
Table P2905.4
C151/A21.51—02Standard for Ductile-iron Pipe, Centrifugally Cast, for WaterTable P2905.4
C153/A21.53—00Standard for Ductile-iron Compact Fittings for Water Service Table P2905.6
C510—00Double Check Valve Backflow Prevention AssemblyTable P2902.3, P2902.3.6
C511—00Reduced-pressure Principle Backflow Prevention AssemblyTable P2902.3,
P2902.3.5, P2902.5.1
C901—08Polyethylene (PE) Pressure Pipe and Tubing 1/2 in. (13 mm)
through 3 in. (76 mm) for Water Service
P2905.4
C904—06 Cross-Linked Polyethylene (PEX) Pressure Pipe, 1/2 in. (12 mm) through 3 in. (76 mm)
for Water Service
P2905.4
CGSBCanadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
Standard
reference
number
Title Referenced
in code
section number
CAN/CGSB-37.54—95Polyvinyl Chloride Roofing and Waterproofing MembraneR905.13.2
37-GP-52M—(1984) Roofing and Waterproofing Membrane, Sheet Applied, ElastomericR905.12.2
37-GP-56M—(1980) Membrane, Modified Bituminous, Prefabricated and Reinforced for
Roofing—with December 1985 Amendment
Table R905.11.2
CISPICast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga, TN 37421
Standard
reference
number
Title Referenced
in code
section number
301—04a Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste and Vent Piping Applications
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3005.2.9, Table P3302.1
310—04 Standard Specification for Coupling for Use in Connection with Hubless
Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain,
Waste and Vent Piping Applications
P3003.6.3
CPAComposite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
Standard
reference
number
Title Referenced
in code
section number
ANSI A135.4—04Basic HardboardTable R602.3(2)
ANSI A135.5—04Prefinished Hardboard PanelingR702.5
ANSI A135.6—06Hardboard SidingTable R703.4
CPSCConsumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
Standard
reference
number
Title Referenced
in code
section number
16 CFR, Part 1201—(2002)Safety Standard for Architectural GlazingR308.1.1, R308.3.1, Table R308.3.1(1)
16 CFR, Part 1209—(2002) Interim Safety Standard for Cellulose Insulation R302.10.3
16 CFR, Part 1404—(2002) Cellulose InsulationR302.10.3
CSACanadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4N 5N6
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
N1102.4.3
ANSI/CSA America
FCI—03
Stationary Fuel Cell Power SystemsM1903.1
ANSI Z21.56/CSA 4.7—06Gas-Fired Pool HeatersG2441.1
ASME A112.18.1/
CSA B125.1—2005
Plumbing Supply FittingsP2708.4, P2722.1, P2722.2, P2722.3
ASME A112.18.2/
CSA B125.2—05
Plumbing Waste FittingsTable P2701.1, P2702.2
ASME A112.19.2/
CSA B45.1—08
Ceramic Plumbing FixturesTable P2701.1, P2711.1, P2712.1
ASME A112.19.1/
CSA B45.2—02
Enameled Cast-Iron and Enameled Steel Plumbing FixturesTable 2701.1, P2711.1
ASME A112.19.3—2008/
CSA B45.4—2008
Stainless Steel Plumbing FixturesTable P2701.1, P2705.1, P2711.1, P2712.1
A112.19.5/
CSA B45.15—2009
Trim for Water-closet Bowls, Tanks and UrinalsTable P2701.1
CSA 8—93Requirements for Gas Fired Log Lighters for Wood Burning Fireplaces—
with revisions through January 1999
G2433.1
O325—07Construction SheathingR503.2.1, R602.3, R604.1, R903.2.1
O437-Series—93Standards on OSB and Waferboard (Reaffirmed 2006) R503.2.1, R602.3, R604.1, R803.2.1
CAN/CSA A257.1M—92Circular Concrete Culvert, Storm Drain, Sewer Pipe and FittingsTable P3002.2
CAN/CSA A257.2M—92Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and FittingsTable P3002.2
CAN/CSA A257.3M—92Joints for Circular Concrete Sewer and Culvert Pipe,
Manhole Sections and Fittings Using Rubber Gaskets
P3003.7, P3003.18
CAN/CSA B64.1.1—01Vacuum Breakers, Atmospheric Type (AVB)Table P2902.2, P2902.3.2
CAN/CSA B64.2—01Vacuum Breakers, Hose Connection Type (HCVP)Table P2902.2, P2902.3.2
CAN/CSA B64.2.2—01Vacuum Breakers, Hose Connection Type (HCVP) with
Automatic Draining Feature
Table P2902.2, P2902.3.2
CAN/CSA B64.3—01Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP)Table P2902.2, P2902.3.3
CAN/CSA B64.4—01Backflow Preventers, Reduced Pressure Principle Type (RP)Table P2902.3,
101/I.S.2/A440—08Specifications for Windows, Doors and Unit SkylightsR308.6.9, R612.6
B45.5—02 (R2008)Plastic Plumbing FixturesTable P2701.1, P2711.2, P2712.1
B45.9—99 (R2008)Macerating Systems and Related ComponentsP3007.1, P3007.2.1, P3007.5
B64.1.2—07Pressure Vacuum Breakers (PVB)Table P2902.2, P2902.3.4
B64.1.3—07Spill Resistant Pressure Vacuum Breakers (SRPVB)P2902.3
B64.2.1—07Hose Connection Vacuum Breakers (HCVB)
with Manual Draining Feature
Table P2902.2, P2902.3.2
B64.2.1.1—07Hose Connection Dual Check Vacuum Breakers (HCDVB)Table P2902.2, P2902.3.2
B64.3—07Dual Check Backflow Preventers with Atmospheric Port (DCAP)Table P2902.2
B64.4.1—07Reduced Pressure Principle for Fire Sprinklers (RPF) Table P2902.2
B64.5—07Double Check Backflow Preventers (DCVA) Table P2902.2, P2902.3.6
B64.5.1—07Double Check Valve Backflow Preventers,
Type for Fire Systems (DCVAF)
Table P2902.2, P2902.3.6
B64.6—07Dual Check Valve Backflow Preventers (DuCTable P2902.3
B64.7—07Laboratory Faucet Vacuum Breakers (LFVB)Table P2902.2, P2902.3.2
B125.3—05Plumbing FittingsTable 2701.1, P2713.3, P2721.2
B137.1—05Polyethylene (PE) Pipe, Tubing and Fittings for
Cold Water Pressure Services
Table P2905.4, Table P2905.6
B137.2—05Polyvinylchloride PVC Injection-moulded Gasketed Fittings for
Pressure Applications
Table P2905.6
B137.3—05Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure ApplicationsTable P2905.4, P3003.9.2,
P3003.14.2
B137.5—05Cross-linked Polyethylene (PEX) Tubing Systems for Pressure ApplicationsTable P2905.4,
Table P2905.5, Table P2905.6
B137.6—05Chlorinated polyvinylchloride CPVC Pipe, Tubing and Fittings For Hot- and
Cold-water Distribution Systems
Table P2905.4,
Table P2905.5, Table 2905.6
B137.9—05Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe Systems
P2505.11.1, Table P2905.4
B137.10M—05Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX)
Composite Pressure Pipe Systems
Table M2101.1, P2505.11.1,
Table P2905.4, Table P2905.5
B137.11—05Polypropylene (PP-R) Pipe and Fittings for Pressure ApplicationsTable P2905.4.1, Table 2905.4,
Table P2905.6
B181.1—06Acrylonitrile-butadiene-styrene (ABS) Drain, Waste and Vent Pipe
and Pipe Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3003.3.2, P3003.8.2
B181.2—06Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC)
Drain, Waste and Vent Pipe and Pipe Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3003.9.2, P3003.14.2,
P3008.2, Table P3302.1
B181.3—06Polyolefin and polyvinylidene (PVDF) Laboratory Drainage SystemsTable P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.16.1
B182.2—06PSM Type polyvinylchloride (PVC) Sewer Pipe and FittingsTable P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, Table P3302.1
B182.4—06Profile polyvinylchloride (PVC) Sewer Pipe & FittingsTable P3002.2,
Table P3002.3, Table P3302.1
B182.6—06Profile Polyethylene Sewer Pipe and FittingsTable P3302.1
B182.8—06Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and FittingsTable P3302.1
B356—00Water Pressure Reducing Valves for Domestic Water Supply SystemsP2903.3.1
B483.1—07Drinking Water Treatment SystemsP2908.1, P2908.2
B602—05Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer PipeP3003.3.1, P3003.6.3,
P3003.7, P3003.8.1, P3003.14.1, P3003.15, P3003.17.2
LC3—00Appliance Stands and Drain PansP2801.5
P2902.3.5, P2902.5.1
CSSBCedar Shake & Shingle Bureau
P.O. Box 1178
Sumas, WA 98295-1178
Standard
reference
number
Title Referenced
in code
section number
CSSB—97Grading and Packing Rules for Western Red Cedar Shakes and Western
Red Shingles of the Cedar Shake and Shingle Bureau
R702.6, R703.5, Table R905.7.4,
Table R905.8.5
DASMADoor and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
Standard
reference
number
Title Referenced
in code
section number
108—05Standard Method for Testing Garage Doors: Determination of Structural
Performance Under Uniform Static Air Pressure Difference
R612.4
115—05 Standard Method for Testing Garage Doors: Determination of Structural
Performance Under Missile Impact and Cyclic Wind Pressure
R301.2.1.2
DOCUnited States Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230
Standard
reference
number
Title Referenced
in code
section number
PS 1—09Structural PlywoodR404.2.1, Table R404.2.3, R503.2.1,
R602.3, R604.1, R613.3.2, R803.2.1
PS 2—10Performance Standard for Wood-based Structural-use PanelsR404.2.1, Table R404.2.3,
R503.2.1, R602.3, R604.1, R613.3.2, Table 613.3.2, R803.2.1
PS 20—05American Softwood Lumber StandardR404.2.1, R502.1, R602.1, R802.1
DOTnDepartment of Transportation
1200 New Jersey Avenue SE
East Building, 2nd floor
Washington, DC 20590
Standard
reference
number
TitleReferenced
in code
section number
49 CFR, Parts 192.281(e)
& 192.283 (b) (2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety StandardsG2414.6.1
FEMAFederal Emergency Management Agency
500 C Street, SW
Washington, DC 20472
Standard
reference
number
TitleReferenced
in code
section number
FA/TB-2—08Flood-damage Resistant Materials RequirementsR322.1.8
FEMA-TB-11—01Crawlspace Construction for Buildings Located in Special Flood Hazard AreaR408.7
FMFactory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P. O. Box 7500
Johnson, RI 02919
Standard
reference
number
TitleReferenced
in code
section number
4450—(1989)Approval Standard for Class 1 Insulated Steel Deck Roofs—with
Supplements through July 1992
R906.1
4880—(2005)American National Standard for Evaluating Insulated Wall or
Wall and Roof/Ceiling Assemblies, Plastic Interior Finish Materials,
Plastic Exterior Building Panels, Wall/Ceiling Coating Systems,
Interior or Exterior Finish Systems
R316.4, R316.6
GAGypsum Association
810 First Street, Northeast, Suite 510
Washington, DC 20002-4268
Standard
reference
number
TitleReferenced
in code
section number
GA-253—07Application of Gypsum SheathingTable R602.3(1)
HPVAHardwood Plywood & Veneer Association
1825 Michael Faraday Drive
Reston, Virginia 20190-5350
Standard
reference
number
TitleReferenced
in code
section number
ANSI/HP-1—2009Standard for Hardwood and Decorative PlywoodR702.5
HVIHome Ventilating Institute
1000 N. Rand Road, Ste 214
Wauconda, IL 60084
Standard
reference
number
TitleReferenced
in code
section number
HVI 916—09Airflow Test ProcedureTable M1507.3
ICCInternational Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
Standard
reference
number
TitleReferenced
in code
section number
IBC—12International Building Code®R101.2, R110.2, R301.1, R301.1.3, R301.2.2.1.1,
R301.2.2.1.2, R301.2.2.4, R301.3, R308.5, R320.1, R321.3,
R322.1, R403.1.8, R602.10.3(3), R606.12.2.1, R802.1.3.4,
R905.10.3, N1102.2.10, G2402.3, Table AH107.4(1), AH107.4.3
ICC/ANSI A117.1—09Accessible and Usable Buildings and FacilitiesR321.3
ICC 400—12Standard on the Design and Construction of Log StructuresR301.1.1
ICC 500—08ICC/NSSA Standard on the Design and Construction of Storm SheltersR323.1
ICC 600—08Standard for Residential Construction in High-wind RegionsR301.2.1.1
IECC—12International Energy Conservation Code®N1101.2
IFC—12International Fire Code®R102.7, M2201.7, G2402.3, G2412.2, G2423.1
IFGC—12International Fuel Gas Code®G2401.1, G2423.1
IMC—12International Mechanical Code®N1103.2.2, N1103.5, G2402.3
IPC—12International Plumbing Code®Table R301.2(1), R903.4.1, G2402.3, R2601.1, AO102.6
IPMC—12International Property Maintenance Code®R102.7
IPSDC—12International Private Sewage Disposal Code®R322.1.7, AI101.1
ISOInternational Organization for Standardization
1, ch. de la Voie - Creuse
Case postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
TitleReferenced
in code
section number
15874—2002Polypropylene Plastic Piping Systems for Hot and Cold Water InstallationsTable M2101.1
MSSManufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, Northeast
Vienna, VA 22180
Standard
reference
number
TitleReferenced
in code
section number
SP-58—93Pipe Hangers and Supports—Materials, Design and ManufactureG2418.2
NAIMANorth American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
reference
number
TitleReferenced
in code
section number
AH 116—09Fibrous Glass Duct Construction Standards, Fifth EditionM1601.1.1
NCMANational Concrete Masonry Association
13750 Sunrise Valley Drive
Herndon, VA 20171-4662
Standard
reference
number
TitleReferenced
in code
section number
TR 68-A—75Design and Construction of Plain and Reinforced Concrete Masonry and
Basement and Foundation Walls
R404.1.1
NFPANational Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Standard
reference
number
TitleReferenced
in code
section number
13—10Installation of Sprinkler SystemsR302.3
13D—10Standard for the Installation of Sprinkler Systems in One- and Two-family
Dwellings and Manufactured Homes
R313.2.1,P2904.1,P2904.2,P2904.6.1
31—11Installation of Oil-burning EquipmentM1801.3.1,M1805.3
58—11Liquefied Petroleum Gas CodeG2412.2,G2414.6.2
70—11National Electrical CodeE3401.1,E3401.2,E4301.1, TableE4303.2,E4304.3,E4304.4
72—10National Fire Alarm CodeR314.1,R314.2
82—09Standard on Incinerators and Waste Linen Handling Systems and EquipmentG2427.2.3
85—11Boiler and Construction Systems Hazards CodeG2452.1
211—10Chimneys, Fireplaces, Vents and Solid Fuel Burning AppliancesR1002.5,G2427.5.5.1
259—08Test Method for Potential Heat of Building MaterialsR316.5.7,R316.5.8
275—09Standard Method of Fire Tests for the Evaluation of
Thermal Barriers Used Over Foam Plastic Insulation
R316.4
286—11Standard Methods of Fire Tests for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth
R302.9.4,R316.4,
R316.5.8,R316.6
501—10Standard on Manufactured HousingR202,AE201
720—09Standard for the Installation of Carbon Monoxide (CO) Detectors and Warning EquipmentR315.2
853—10Standard for the Installation of Stationary Fuel Cell Power SystemsM1903.1
NFRC National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt, MD 20770
Standard
reference
number
TitleReferenced
in code
section number
100-2010 Procedure for Determining Fenestration Products U-factorsN1101.12.3
200-2010 Procedure for Determining Fenestration Product Solar Heat Gain Coefficients And Visible Transmittance at Normal IncidenceN1101.12.3
400-2010 Procedure for Determining Fenestration Product Air LeakageN1102.4.3
NSFNSF International
789 N. Dixboro
Ann Arbor, MI 48105
Standard
reference
number
TitleReferenced
in code
section number
14—2008ePlastics Piping System Components and Related MaterialsM1301.4, P2608.3, P2908.3
42—2007aeDrinking Water Treatment Units—Anesthetic EffectsP2908.1, P2908.3
44—2007Residential Cation Exchange Water SoftenersP2908.1, P2908.3
53—2007aDrinking Water Treatment Units—Health EffectsP2908.1, P2908.3
58—2007Reverse Osmosis Drinking Water Treatment SystemsP2908.2, P2908.3
61—2008Drinking Water System Components—Health EffectsP2608.5, P2722.1, P2903.9.4,
P2905.4, P2905.5, P2905.6, P2907.3
PCAPortland Cement Association
5420 Old Orchard Road
Skokie, IL 60077
Standard
reference
number
TitleReferenced
in code
section number
100—07Prescriptive Design of Exterior Concrete Walls for One- and
Two-family Dwellings (Pub. No. EB241)
R301.2.2.2.4, R301.2.2.3.4, R404.1.2,
R404.1.2.2.1, R404.1.2.2.2, R404.1.2.4, R404.1.4.2,
R611.1, R611.2, R611.9.2, R611.9.3
SBCAStructural Building Components Association
6300 Enterprise Lane
Madison, WI 53719
Standard
reference
number
TitleReferenced
in code
section number
BCSI—2008Building Component Safety Information Guide to Good Practice for Handling,
Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses
502.11.2, 802.10.3
CFS-BCSI—2008Guide to Good Practice for Handling, Installing & Bracing of Cold-formed Steel Trusses505.1.3, 804.3.7
SMACNASheet Metal & Air Conditioning Contractors National Assoc. Inc.
4021 Lafayette Center Road
Chantilly, VA 22021
Standard
reference
number
TitleReferenced
in code
section number
SMACNA—10Fibrous Glass Duct Construction Standards (2003)M1601.1.1, M1601.4.1
SMACNA/ANSI-2005HVAC Duct Construction Standards—Metal and Flexible (2005)M1601.4.1
TMSThe Masonry Society
3970 Broadway, Suite 201-D
Boulder, CO 80304
Standard
reference
number
TitleReferenced
in code
section number
302—07Standard Method for Determining the Sound Transmission
Class Rating for Masonry Walls
AK102.1.1
402—11Building Code Requirements for Masonry StructuresR404.1.1, R606.1, R606.1.1,
R606.12.1, R606.12.2.3.1,
R606.12.3.2, Table R703.4
403—10Direct Design Handbook for Masonry StructuresR606.1, R606.1.1, R606.12.1,
R606.12.3.1
602—11Specification for Masonry StructuresR404.1.1, R606.12.3.1,
Table R703.4
TPITruss Plate Institute
583 D'Onofrio Drive, Suite 200
Madison, WI 53719
Standard
reference
number
TitleReferenced
in code
section number
TPI 1—2007National Design Standard for Metal-plate-connected
Wood Truss Construction
R502.11.1, R802.10.2
ULUnderwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
Title Referenced
in code
section number
17—2008Vent or Chimney Connector Dampers for Oil-fired AppliancesM1802.2.2
55A—04Materials for Built-up Roof CoveringsR905.9.2
58—96 Steel Underground Tanks for Flammable and Combustible Liquids—
with Revisions through July 1998
M2201.1
80—07Steel Tanks for Oil-burner Fuel M2201.1
103—01Factory-built Chimneys for Residential Type and Building Heating
Appliances—with revisions through March 2010
R202, R1005.3, G2430.1
127—08Factory-built Fireplaces—with revisions through January 2010R1001.11, R1004.1,
R1004.4, R1005.4, G2445.7,
174—04 Household Electric Storage Tank Water Heaters—
with revisions through November 2005
M2005.1
180—03Liquid-level Indicating Gauges for Oil Burner Fuels—with revision through March 2007M2201.5
181—05Factory-made Air Ducts and Air Connectors—with revisions through May 2003M1601.2, M1601.4.1
181A—05Closure Systems for Use with Rigid Air Ducts and Air Connectors—
with revisions through December 1998
M1601.2, M1601.4.1
181B—05Closure Systems for Use with Flexible Air Ducts and Air Connectors—
with revisions through August 2003
M1601.2, M1601.4.1
217—06Single- and Multiple-station Smoke Alarms—with revisions through April 2010R314.1
263—03 Standards for Fire Test of Building Construction and Materials—
with revisions through October 2007
Table R302.1(2), R302.2, R302.3, R302.4.1, R316.4
325—02Door, Drapery, Gate, Louver and Window Operations and Systems—
with revisions through February 2010
R309.4
343—97Pumps for Oil-burning Appliances—with revisions through May 2002M2204.1
378—06Draft EquipmentM1804.2.6
441—10Gas VentsG2426.1
508—99Industrial Control Equipment—with revisions through April 2010M1411.3.1
536—97Flexible Metallic Hose—with revisions through June 2003M2202.3
641—95Type L, Low-temperature Venting Systems—
with revisions through July 2009
R202, R1003.11.5, M1804.2.4, G2426.1
651—05Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings—
with revisions through March 2010
G2414.6.3
723—2008Standard for Test for Surface Burning Characteristics of
Building Materials
R302.9.3, R302.9.4, R302.10.1, R302.10.2,
R316.3, R316.5.9, R316.5.10, R316.6, R802.1.3, M1601.3
726—95Oil-fired Boiler Assemblies—with revisions through April 2010M2001.1.1, M2006.1
727—06Oil-fired Central Furnaces—with revisions through April 2010M1402.1
729—03Oil-fired Floor Furnaces—with revisions through April 2010M1408.1
730—03Oil-fired Wall Furnaces—with revisions through April 2010M1409.1
732—95Oil-fired Storage Tank Water Heaters—with revisions through April 2010M2005.1
737—07Fireplaces StovesM1414.1, M1901.2
790—04Standard Test Methods for Fire Tests of Roof Coverings—with revisions through October 2008R902.1
795—06Commercial-industrial Gas Heating Equipment—
with revisions through April 2010
G2442.1, G2452.1
834—04Heating, Water Supply and Power Boilers—Electric—with revisions
through December 2009
M2001.1.1
842—07Valves for Flammable FluidsM2204.2
858—05Household Electric Ranges—with revisions through November 2007M1901.2
875—09Electric Dry-bath HeatersM1902.2
896—93Oil-burning Stoves—with revisions through May 2010M1410.1
923—08Microwave Cooking Appliances—with revisions through June 2010M1504.1
959—01Medium Heat Appliance Factory-built Chimneys—
with revisions through June 2010
R1005.6
1026—07Electric Household Cooking and Food Serving AppliancesM1901.2
1040—96Fire Test of Insulated Wall Construction—with revisions through June 2001R316.4, R316.6
1042—94Electric Baseboard Heating Equipment—with revisions through February 2008M1405.1
1256—02Fire Test of Roof Deck Construction—with revisions through January 2007R906.1
1261—01Electric Water Heaters for Pools and Tubs—with revisions through June 2004M2006.1
1453—04Electronic Booster and Commercial Storage Tank Water Heaters—
with revisions through December 2009
M2005.1
1479—03Fire Tests of Through-Penetration Firestops—with revisions through March 2010R302.4.1.2
1482—10Solid-Fuel-type Room HeatersR1002.2, R1002.5, M1410.1
1618—09Wall Protectors, Floor Protectors, and Hearth ExtensionsM1004.2
1673—96Electric Space Heating Cables—with Revisions through July 2003M1406.1
1693—02Electric Radiant Heating Panels and Heating Panel SetsM1406.1
1703—02Flat-plate Photovoltaic Modules and Panels—with Revisions through April 2008M2302.3
1741—99Inverters, Converters, Controllers and Interconnection System Equipment with
Distributed Energy Resources—with Revisions through November 2005
M2302.4
1715—97Fire Test of Interior Finish Material—with Revisions through March 2004R316.6
1738—06Venting Systems for Gas-burning Appliances, Categories II, III and IVG2426.1
1741—99Inverters, Converters, Controllers and Interconnection System Equipment
for use with Distributed Energy Resources—with Revisions through November 2005
M2302.4
1777—04Chimney Liners with Revisions through June 2009R1003.11.1, R1003.18,
G2425.12, G2425.15.4, M1801.3.4,
1995—05Heating and Cooling Equipment—with Revisions through July 2009M1402.1, M1403.1,
M1407.1, M1412.1, M1413.1
1996—04Electric Duct Heaters—with Revisions through December 2006M1402.1
2017—08Standard for General-purpose Signaling Devices and Systems—
with Revisions through October 2009
AG105.2
2523—03Outline of Investigation for Sealed Fuel-fired Water Heaters and BoilersM2001.1.1
2034—08Standard for Single- and Multiple-station Carbon Monoxide AlarmsR315.4
2075—04Standard for Gas and Vapor Detectors and Sensors—with Revisions
through September 28, 2007
R315.2
2158A—06Outline of Investigation for Clothes Dryer Transition DuctM1502.4.3
ULCUnderwriters’ Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada M1R 3B4
Standard
reference
number
TitleReferenced
in code
section number
CAN/ULC S 102—1988Standard Methods for Test for Surface Burning Characteristics of Building Materials and
Assemblies—with 2000 revisions
R302.10.2
United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
Standard
reference
number
TitleReferenced
in code
section number
CFR Title 16
(May 31, 2005)
R-value Rule303.1.4
WDMAWindow & Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S2/A440—11

Specifications for Windows, Doors and Skylights
R308.6.9, R612.3, N1102.4.3
Resources