This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ACCAAir Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
Reference
Number
Title Referenced
in code
section number
Manual D—09 Residential Duct Systems 603.2
183—2007 Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings 312.1
AHRIAir-Conditioning, Heating and Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
Standard
Reference
Number
Title Referenced
in code
section number
700—2006 Purity Specifications for Fluorocarbon and Other Refrigerants 1102.2.2.3
AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
Standard
Reference
Number
Title Referenced
in code
section number
550—08 Test Method for High Velocity Wind Driven Rain Resistant Louvers401.5, 501.3.2
ANSIAmerican National Standards Institute
11 West 42nd Street
New York, NY 10036
Standard
Reference
Number
Title Referenced
in code
section number
Z21.8—1994 (R2002) Installation of Domestic Gas Conversion Burners 919.1
ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
Reference
Number
Title Referenced
in code
section number
ASHRAE-2009 ASHRAE Fundamentals Handbook603.2
15—2010 Safety Standard for Refrigeration Systems 1101.6, 1105.8, 1108.1
34—2010Designation and Safety Classification of Refrigerants202, 1102.2.1, 1103.1
62.1—2010Ventilation for Acceptable Indoor Air Quality403.3.2.3.2
180 —2008Standard Practice for Inspection and Maintenance of Commercial
Building HVAC Systems
102.3
ASMEAmerican Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
Reference
Number
Title Referenced
in code
section number
B1.20.1—1983 (R2006) Pipe Threads, General Purpose (Inch) 1203.3.5, 1303.3.3
B16.3—2006 Malleable Iron Threaded Fittings, Classes 150 & 300 Table 1202.5
B16.5—2003 Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24Table 1202.5
B16.9—2007 Factory Made Wrought Steel Buttwelding Fittings Table 1202.5
B16.11—2005 Forged Fittings, Socket-welding and Threaded Table 1202.5
B16.15—2006 Cast Bronze Threaded FittingsTable 1202.5
B16.18—2001
(Reaffirmed 2005)
Cast Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.22—2001
(Reaffirmed 2005)
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.23—2002
(Reaffirmed 2006)
Cast Copper Alloy Solder Joint Drainage Fittings DWV Table 1202.5
B16.24—2006 Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900,
1500 and 2500
Table 1202.5
B16.26—2006 Cast Copper Alloy Fittings for Flared Copper TubesTable 1202.5
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and ReturnsTable 1202.5
B16.29—2007 Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings-DWV Table 1202.5
B31.9—08 Building Services Piping 1201.3
BPVC—2007 ASME Boiler & Pressure Vessel Code–07 Edition 1004.1, 1011.1
CSD-1—2009 Controls and Safety Devices for Automatically Fired Boilers1004.1
ASSEAmerican Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
Standard
Reference
Number
Title Referenced
in code
section number
1017—2010 Performance Requirements for Temperature Actuated Mixing Values for
Hot Water Distribution Systems
1002.2.2
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
Reference
Number
Title Referenced
in code
section number
A 53/A 53M—07 Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded
and Seamless
Table1202.4, Table1302.3
A 106/A106M—08 Specification for Seamless Carbon Steel Pipe for High-Temperature ServiceTable 1202.4, Table 1302.3
A 126—04 Specification for Gray Iron Castings for Valves, Flanges and Pipe FittingsTable 1202.5
A 254—97 (2007) Specification for Copper Brazed Steel TubingTable 1202.4,Table1302.3
A 420/A 420M—07 Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel
for Low-Temperature Service
Table 1202.5
A 539—99 Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines Table 1302.3
B 32—08 Specification for Solder Metal 1203.3.3
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes513.13.1,1107.5.2, Table1202.4, Table1302.3
B 43—98(2004) Specification for Seamless Red Brass Pipe, Standard Sizes 513.13.1,1107.5.2
B 68—02Specification for Seamless Copper Tube, Bright Annealed513.13.1
B 75—02Specification for Seamless Copper Tube Table 1202.4,Table 1302.3
B 88—03Specification for Seamless Copper Water Tube513.13.1, 1107.5.3,Table 1202.4,Table 1302.3
B 135—08aSpecification for Seamless Brass TubeTable 1202.4,Table 1302.3
B 251—02e01Specification for General Requirements for Wrought Seamless Copperand Copper-alloy Tube513.13.1, Table 1202.4
B 280—08Specification for Seamless Copper Tube for Air Conditioning andRefrigeration Field Service513.13.1, 1107.4.3,Table 1302.3
B 302—07Specification for Threadless Copper Pipe, Standard Sizes Table 1202.4,Table 1302.3
B 813—00(2009)Specification for Liquid and Paste Fluxes for Soldering of Copper andCopper Alloy Tube1203.3.3
C 315—07Specification for Clay Flue Liners and Chimney Pots801.16.1, Table 803.10.4
C 411—05Test Method for Hot-surface Performance of High-temperature Thermal Insulation604.3
D 56—05Test Method for Flash Point by Tag Closed Tester 202
D 93—08Test Method for Flash Point of Pensky-Martens Closed Cup Tester202
D 1527—99(2005)Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80 Table 1202.4
D 1693—08Test Method for Environmental Stress-Cracking of Ethylene PlasticsTable 1202.4
D 1785—06Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe, Schedules 40, 80 and 120 Table 1202.4
D 2235—04Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS)Plastic Pipe and Fittings1203.3.4
D 2241—05Specification for Poly (Vinyl Chloride)(PVC) Pressure-rated Pipe (SDR-Series)Table 1202.4
D 2282—99(2005)Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)Table 1202.4
D 2412—02(2008)Test Method for Determination of External Loading Characteristics of Plastic Pipeby Parallel-plate LoadingTable 603.8.3
D 2447—03Specification for Polyethylene (PE) Plastic Pipe, Schedules 40 and 80, Based on Outside DiameterTable 1202.4
D 2466—06Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 40Table 1202.5
D 2467—06Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 80Table 1202.5
D 2468—96aSpecification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40Table 1202.5
D 2513—08bSpecification for Thermoplastic Gas Pressure Pipe, Tubing, and FittingsTable 1202.4
D 2564—04e01Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems1203.3.4
D 2657—07Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings1203.15.1
D 2683—04Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlledPolyethylene Pipe and TubingTable 1202.4,1203.15.1
D 2837—08Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials orPressure Design Basis for Thermoplastic Pipe ProductsTable 1202.4
D 2846/D 2846M—09Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot andCold Water Distribution Systems Table 1202.4,1203.3.4
D 2996—01(2007)e01Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe Table 1302.3
D 3035—08Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside DiameterTable 1202.4
D 3278—96(2004)Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus202
D 3261—03Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings forPolyethylene (PE) Plastic Pipe and Tubing1203.15.1
D 3309—96a(2002)Specification for Polybutylene (PB) Plastic Hot and Cold Water Distribution Systems.Table 1202.4,1203.10.1
D 3350—08Specification for Polyethylene Plastics Pipe and Fittings MaterialsTable 1202.4
E 84—09Test Method for Surface Burning Characteristics of Building Materials202,510.8,602.2.1, 602.2.1.5,604.3,1204.1
E 119—08aTest Method for Fire Tests of Building Construction and Materials607.5.2,607.5.5,607.6.1,607.2.1
E 136—09Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C202
E 814—08bTest Method for Fire Tests of Through-penetration Fire Stops 506.3.10.2,506.3.10.3
E 1509—04Specification for Room Heaters, Pellet Fuel-burning Type904.1
E 2231—04Standard Practice For Specimen Preparation and Mounting of Pipe and Duct Insulation Materialsto Assess Surface Burning Characteristics604.3,1204.1
E 2336—04Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems506.3.6,506.3.10.2
F 438—04Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,Schedule 40Table 1202.5
F 439—06Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,Schedule 80Table 1202.5
F 441/F 441M—02(2008)Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80Table 1202.4
F 442/F 442M—99(2005)e1Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)Table 1202.4
F 493—04Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipeand Fittings 1203.3.4
F 876—08bSpecification for Crosslinked Polyethylene (PEX) TubingTable 1202.4
F 877—07Specification for Crosslinked Polyethylene (PEX) Plastic Hot and Cold WaterDistribution SystemsTable 1202.4,Table 1202.5
F 1055—98(2006)Specification for Electrofusion Type Polyethylene Fittings for OutsideDiameter Controlled Polyethylene Pipe and TubingTable 1202.4,1203.15.2
F 1281—07Specification for Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene(PEX-AL-PEX) Pressure PipeTable 1202.4
F 1282—06Standard Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) CompositePressure PipeTable 1202.4
F 1476—07Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications1203.3.7
F 1807—08Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR 9Cross-linked Polyethylene (PEX) TubingTable 1202.5
F 1924—05Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter ControlledPolyethylene Gas Distribution Pipe and Tubing 1203.15.3
F 1974—08Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and CrosslinkedPolyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure PipeTable 1202.5
F 2159—05Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR 9Cross-linked Polyethylene (PEX) TubingTable 1202.5
F 2389—07e1Specification for Pressure-rated Polypropylene Piping SystemsTable 1202.4,Table 1202.5
F 2623—08Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing1Table 1202.4
F 2735—08aStandard Specification for Plastic Insert Fittings for SDR 9 Cross-linked Polyethylene (PEX)and Raised Temperature (PE-RT) TubingTable 1202.5
F 2769—09Polyethylene of Raised Temperature (PE-RT) Plastic Hot and Cold-water Tubing andDistribution SystemsTable 1202.4
AWS American Welding Society
550 N.W. LeJeune Road
P.O. Box 351040
Miami, FL 33135
Standard
Reference
Number
Title Referenced
in code
section number
A5.8—2004 Specifications for Filler Metals for Brazing and Braze Welding 1203.3.1, 1303.3.1
AWWA American Water Work Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
Reference
Number
Title Referenced
in code
section number
C110/A21.10—03 Standard for Ductile Iron & Gray Iron Fittings, 2 inches Through 48 inches for Water Table 1202.5
C115/A21.15—99 Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded Flanges Table 1202.4
C151/A21.51—02 Standard for Ductile-iron Pipe, Centrifugally Cast for Water Table 1202.4
C153/A21.53—00 Standard for Ductile-iron Compact Fittings for Water ServiceTable 1202.5
CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
Reference
Number
Title Referenced
in code
section number
B137.9—05 Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems Table 1202.4
B137.10—05 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX)
Composite Pressure-pipe Systems
Table 1202.4
ANSI CSA
America FC1—03
Stationary Fuel Cell Power Systems 924.1
DOL Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402-9325
Standard
Reference
Number
Title Referenced
in code
section number
29 CFR Part 1910.1000 (2009) Air Contaminants 502.6
29 CFR Part 1910.1025
(2009)
Toxic and Hazardous Substances502.19
FSFederal Specifications*
General Services Administration
7th & D Streets
Specification Section, Room 6039
Washington, DC 20407
Standard
Reference
Number
Title Referenced
in code
section number
WW-P-325B (1976) Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and
Waste Applications
Table 1202.4
*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325
ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
Reference
Number
Title Referenced
in code
section number
IBC—12 International Building Code®201.3, 202, 301.12, 301.12, 301.14, 301.15, 302.1, 302.2, 304.7, 304.10, 308.8, 308.10,
401.4, 401.6, 406.1, 502.10, 502.10.1, 504.2,
506.3.3, 506.3.10, 506.3.12.2, 506.4.1, 509.1,
510.6, 510.6.3, 510.6.2, 510.7, 511.1.5, 513.1,
513.2, 513.3, 513.4.3, 513.5, 513.5.2, 513.5.2.1,
513.6.2, 513.10.5, 513.12, 513.12.2, 513.20,
602.2.1.5.1, 602.2.1.5.2, 602.3, 603.1, 603.10,
604.5.4, 607.1.1, 607.3.2.1, 607.5.1, 607.5.2,
607.5.3, 607.5.4, 607.5.4.1, 607.5.5, 607.5.5.1,
607.6, 607.6.2, 701.4.1, 701.4.2, 801.3, 801.16.1,
801.18.4, 902.1, 908.3, 908.4, 910.3, 925.1,
1004.6, 1105.1, 1206.4, 1402.4, 1402.4.1
IEBC—12 International Existing Building Code® 101.2
IECC—12 International Energy Conservation Code®202, 301.2, 303.3, 312.1, 603.9, 604.1, 1204.1, 1204.2
IFC—12 International Fire Code®201.3, 310.1, 311.1, 502.4, 502.5, 502.7.2, 502.8.1, 502.9.5, 502.9.5.2, 502.9.5.3,
502.9.8.2, 502.9.8.3, 502.9.8.5, 502.9.8.6, 502.10,
502.10.3, 502.16.2, 509.1, 510.2.1, 510.2.2, 510.4,
511.1.1 513.12.3, 513.15, 513.16, 513.17, 513.18, 513.19,
513.20.2, 513.20.3, 606.2.1, 908.7, 1101.9,
1105.3, 1105.9, 1106.5, 1106.6, 1301.1, 1301.2
IFGC—12 International Fuel Gas Code®101.2, 201.3, 301.3, 701.1, 801.1, 901.1, 906.1, 1101.5
IPC—12 International Plumbing Code®201.3, 301.8, 512.2, 908.5, 1002.1, 1002.2, 1002.3, 1005.2, 1006.6, 1008.2, 1009.3, 1101.4, 1201.1, 1206.2, 1206.3, 1401.2
IRC—12 International Residential Code®101.2
IIAR International Institute of Ammonia Refrigeration
1110 North Glebe Road
Arlington, VA 22201
Standard
Reference
Number
Title Referenced
in code
section number
2—99
(with Addendum A—2005)
Addendum A to Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems 1101.6
MSS Manufacturers Standardization Society of the Valve & Fittings Industry, Inc.
127 Park Street, N.E.
Vienna, VA 22180
Standard
Reference
Number
Title Referenced
in code
section number
SP-69—2002 Pipe Hangers and Supports-Selection and Application 305.4
NAIMA North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
Reference
Number
Title Referenced
in code
section number
AH116—09 Fibrous Glass Duct Construction Standards 603.5, 603.9
NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Standard
Reference
Number
Title Referenced
in code
section number
30A—12 Code for Motor Fuel-dispensing Facilities and Repair Garages304.6
31—11 Installation of Oil-burning Equipment801.2.1, 801.18.1, 801.18.2, 920.2, 922.1, 1308.1
37—10 Stationary Combustion Engines and Gas Turbines915.1, 915.2
58—11 Liquefied Petroleum Gas Code502.9.10
69—08 Explosion Prevention Systems510.8.3
70—11National Electrical Code 301.7, 306.3.1, 306.4.1, 511.1.1, 513.11, 513.12.1, 602.2.1.1, 1106.3, 1106.4
72—10 National Fire Alarm Code 606.3
82—09 Incinerators and Waste and Linen Handling Systems and Equipment 601.1
91—10 Exhaust Systems for Air Conveying of Vapors, Gases, and Noncombustible
Particulate Solids
502.9.5.1, 502.17
92B—09 Smoke Management Systems in Malls, Atria and Large Spaces 513.8
96—08 Standard for Ventilation Control and Fire Protection Cooking Operations507.2
211—10 Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances806.1
262—11 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for
Use in Air-handling Spaces
602.2.1.1
704—12 Identification of the Hazards of Materials for Emergency Response 502.8.4, Table 1103.1, 510.1
853—10 Installation of Stationary Fuel Power Plants 924.1
850 1—97 Single Burner Boiler Operation 1004.1
8502—99Prevention of Furnace Explosions/Implosions in Multiple Burner Boiler-furnaces1004.1
8504—96 Atmospheric Fluidized-bed Boiler Operation 1004.1
NSF NSF International
789 Dixboro Road
Ann Arbor, MI 48105
Standard
Reference
Number
Title Referenced
in code
section number
14—2011 Plastic Piping System Components and Related Materials301.4
SMACNA Sheet Metal & Air Conditioning Contractors National Assoc., Inc.
4201 Lafayette Center Drive
Chantilly, VA 20151-1209
Standard
Reference
Number
Title Referenced
in code
section number
SMACNA/ANSI—2005 HVAC Duct Construction Standards-Metal and Flexible (2005)603.4, 603.9
SMACNA—10Fibrous Glass Duct Construction Standards 603.5, 603.9
UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
Reference
Number
Title Referenced
in code
section number
17—2008 Vent or Chimney Connector Dampers for Oil-fired Appliances803.6
103—01 Factory-built Chimneys, Residential Type and Building Heating Appliance—
with Revisions through March 2010
805.2
127—08 Factory-built Fireplaces—with Revisions through January 2010 805.3, 903.1, 903.3
174—04 Household Electric Storage Tank Water Heaters—with Revisions through May 2006 1002.1
180—03 Liquid-level Indicating Gauges for Oil Burner Fuels—with Revisions through March 2007 1306.4
181—05 Factory-made Air Ducts and Air Connectors—with Revisions through October 2008512.2, 603.5, 603.6.1, 603.6.2, 604.13
181A—05 Closure Systems for Use with Rigid Air Ducts and Air Connectors—
with Revisions through February 2008
603.9
181B—05Closure Systems for Use with Flexible Air Ducts and Air Connectors—
with Revisions through February 2008
603.9
207—2009 Refrigerant-containing Components and Accessories, Nonelectrical1101.2
263—2003 Standard for Fire Test of Building Construction and Materials—
with Revisions through October 2007
607.5.2, 607.5.5, 607.6.1
268—2009 Smoke Detectors for Fire Prevention Signaling 606.1
268A—2008 Smoke Detectors for Duct Application, with Revisions through September 2009606.1
343—2008 Pumps for Oil-Burning Appliances 1302.7
378—06 Draft Equipment804.3, 804.3.8
391—2006 Solid-fuel and Combination-fuel Central and Supplementary Furnaces—
with Revisions through March 2010
918.1
412—04 Refrigeration Unit Coolers—with Revisions through January 2009 1101.2
471—06 Commercial Refrigerators and Freezers—with Revisions through October 20081101.2
499—05 Electric Heating Appliances—with Revisions through August 2008 912.1, 923.1
508—99 Industrial Control Equipmentamp;mdash;with Revisions through September 2008 307.2.3
536—97 Flexible Metallic Hose—with Revisions through June 2003 1302.8
555—06Fire Dampers—with Revisions through May 2010 607.3
555C—06 Ceiling Dampers—with Revisions through May 2010 607.3.1
555S—99 Smoke Dampers—with Revisions through May 2010 607.3.1
586—2009High-Efficiency, Particulate, Air Filter Units 605.2
641—95Type L Low-temperature Venting Systems—with Revisions through July 2009802.1
710—95 Exhaust Hoods for Commercial Cooking Equipment—with Revisions through December 2009 507.1
710B—04Recirculating Systemsamp;mdash;with Revisions through April 2006 507.1
723—2008 Standard for Test for Surface Burning Characteristics of Building Materials510.8, 602.2.1, 602.2.1.5, 604.3, 1204.1
726—95 Oil-fired Boiler Assemblies—with Revisions through April 2010 916.1, 1004.1
727—06 Oil-fired Central Furnaces 918.1
875—09 Electric Dry Bath Heater—with Revisions through October 2009914.2
896—93 Oil-burning Stoves—with Revisions through May 2010 917.1, 922.1
900—04 Air Filter Units—with Revisions through November 2009 605.2
923—2008Microwave Cooking Appliances—with Revisions through June 2010 914.2
907—94Fireplace Accessories—with Revisions through July 2006901.4
959—01 Medium Heat Appliance Factory-built Chimneys—with Revisions through June 2010 805.5
1046—00 Grease Filters for Exhaust Ducts507.11
1240—05Electric Commercial Clothes—Drying Equipment—with Revisions through October 2009 913.1
1261—01 Electric Water Heaters for Pools and Tubs—with Revisions through May 2008916.1
1453—04 Electric Booster and Commercial Storage Tank Water Heaters—
with Revisions through December 2009
1002.1
1479—03Fire Tests of Through-penetration Firestops—with Revisions through April 2007 506.3.10.2, 506.3.10.3
1482—2010 Solid-fuel Type Room Heaters905.1
1618—09Wall Protectors, Floor Protectors and Hearth Extensions308.5, 903.2, 905.3
1777—2007 Chimney Liners—with Revisions through July 2009801.16.1, 801.18.4
1812—2009Standard for Ducted Heat Recovery Ventilators—with Revisions through June 2010927.1
1815—2009 Standard for Nonducted Heat Recovery 927.2
1820—04Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics—
with Revisions through February 2009
602.2.1.3
1887—04 Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics—
with Revisions through February 2009
602.2.1.2
1978—05Grease Ducts—with Revisions through June 2009506.3.2
1995—05Heating and Cooling Equipment—with Revisions through July 2009911.1, 918.1, 918.3, 1101.2
1996—04Electric Duct Heaters—with Revisions through December 2006911.1
2024—2008Standard for Safety Optical-Fiber and Communications Cable Raceway602.2.1.1
2043—2008Fire Test for Heat and Visible Smoke Release for Discrete Products and their Accessories
Installed in Air-handling Spaces
602.2.1.4.2
2158—97Electric Clothes Dryers—with Revisions through March 2009504.6.3, 913.1
2158A—2006Outline of Investigation for Clothes Dryer Transition Duct 504.6.3
2162—01Outline of Investigation for Commercial Wood-fired Baking Ovens-Refractory Type917.1
2200—98Stationery Engine Generator Assemblies—with Revisions through December 2009915.1
2221—01Tests of Fire Resistive Grease Duct Enclosure Assemblies506.3.10.3
2518—02Air Dispersion System Materials603.17
2523—09Solid Fuel-fired Hydronic Heating Appliances1002.1, 1004.1
Resources