CODES

ADOPTS WITH AMENDMENTS:

International Residential Code 2012 (IRC 2012)

Copyright

Preface

Chapter 1 Scope and Administration

Chapter 2 Definitions

Chapter 3 Building Planning

Chapter 4 Foundations

Chapter 5 Floors

Chapter 6 Wall Construction

Chapter 7 Wall Covering

Chapter 8 Roof-Ceiling Construction

Chapter 9 Roof Assemblies

Chapter 10 Chimneys and Fireplaces

Chapter 11 [Re] Energy Efficiency

Chapter 12 Mechanical Administration

Chapter 13 General Mechanical System Requirements

Chapter 14 Heating and Cooling Equipment and Appliances

Chapter 15 Exhaust Systems

Chapter 16 Duct Systems

Chapter 17 Combustion Air

Chapter 18 Chimneys and Vents

Chapter 19 Special Appliances, Equipment and Systems

Chapter 20 Boilers and Water Heaters

Chapter 21 Hydronic Piping

Chapter 22 Special Piping and Storage Systems

Chapter 23 Solar Energy Systems

Chapter 24 Fuel Gas

Chapter 25 Plumbing Administration

Chapter 26 General Plumbing Requirements

Chapter 27 Plumbing Fixtures

Chapter 28 Water Heaters

Chapter 29 Water Supply and Distribution

Chapter 30 Sanitary Drainage

Chapter 31 Vents

Chapter 32 Traps

Chapter 33 Storm Drainage

Chapter 34 General Requirements

Chapter 35 Electrical Definitions

Chapter 36 Services

Chapter 37 Branch Circuit and Feeder Requirements

Chapter 38 Wiring Methods

Chapter 39 Power and Lighting Distribution

Chapter 40 Devices and Luminaires

Chapter 41 Appliance Installation

Chapter 42 Swimming Pools [Electrical Provisions]

Chapter 43 Class 2 Remote-Control, Signaling and Power-Limited Circuits

Chapter 44 High-Velocity Hurricane Zones

Chapter 45 Private Swimming Pools

Chapter 46 Referenced Standards

Appendix A Sizing and Capacities of Gas Piping

Appendix B Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances, and Appliances Listed for Use With Type B Vents

Appendix C Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems

Appendix D Recommended Procedure for Safety Inspection of an Existing Appliance Installation

Appendix E Florida Standard for Mitigation of Radon in Existing Buildings Effective: June 1, 1994

Appendix F Florida Standard for Passive Radon-Resistant New Residential Building Construction

Appendix G Swimming Pools, Spas and Hot Tubs Reserved

Appendix H Patio Covers

Appendix I Private Sewage Disposal

Appendix J Existing Buildings and Structures

Appendix K Sound Transmission

Appendix L Permit Fees

Appendix M Home Day Care—r-3 Occupancy

Appendix N Venting Methods

Appendix O Automatic Vehicular Gates

Appendix P Sizing of Water Piping System

Appendix Q Florida Residential Code Electrical Provisions/National Electrical Code Cross Reference

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.

AAFAluminum Association of Florida, Inc.
3165 McCrory Place, Suite 185
Orlando, Florida 32803
Standard
reference
number
TitleReferenced
in code
AAF—2010Guide to Aluminum Construction in High Wind Areas 2010R301.2.1.1.1, R4403.12.1.1
AAMAAmerican Architectural Manufacturers Association
1827 Walden Office Square, Suite 550
Schaumburg, IL 60173-4268
Standard
reference
number
TitleReferenced
in code
section number
101/I.S.2–97Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood
Windows and Glass Doors
R308.6.9, R612.3
101/I.S.2/NAFS-02Voluntary Performance Specifications for Windows, Skylights
And Glass Doors
R308.6.9, R612.3
AAMA/WDMA/CSA
101/I.S.2/A440—05 or
08 or 11
North American Fenestration Standards/Specifications for Windows,
Doors and Skylights
R308.6.9, R612.3
450—09Voluntary Performance Rating Method for Mulled Fenestration AssembliesR612.8
506—06 or 08 or 11Voluntary Specifications for Impact and Cycle Testing of Fenestration ProductsR301.2.1.2, R612.6.1
711—07Voluntary Specification for Self-adhering Flashing Used for Installation of
Exterior Wall Fenestration Products
R703.8
AAMA/NPEA/
NSA 2100—11
Voluntary Specifications for SunroomsR202, R301.2.1.1.2.1, R301.2.1.1.2.2
FMA/AAMA 100—12Standard Practice for the Installation of Windows with Flanges or MountingR703.8
FMA/AAMA 200—12Standard Practice for the Installation of Windows with Frontal Flanges
for Surface Barrier Masonry
R703.8
FMA/WDMA 250—10Standard Practice for the Installation of Non-Frontal Flange Windows with
Mounting Flanges for Surface Barrier Masonry for Extreme Wind/Water Conditions
R703.8
FMA/AAMA/WDMA300—12Standard Practice for the Installation of Exterior Doors in Wood Frame
Construction for Extreme Wind/Water Exposure
R703.8
AAMA 800—05Voluntary Specifications and Test Methods for SealantsR703.8
AAMA 812—04Voluntary Practice for Assessment of Single Component Aerosol Expanding
Polyurethane Foams for Sealing Rough Openings of Fenestration Installations
R703.8
ACIAmerican Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
TitleReferenced
in code
section number
318—11Building Code Requirements for Structural Concrete R301.2.2.2.4, R301.2.2.3.4, Table R402.1.2(2),
R402.2, R404.1.2, Table R404.1.2(5),
Table R404.1.2(7), Table R404.1.2(8), Table R404.1.2(9),
R404.1.2.1, R404.1.2.3, R404.1.2.4, R404.1.4.2, R404.5.1, R611.1,
R611.1.1, R611.1.2, R611.2, R611.5.1, R611.6.1, R611.8.2,
R611.9.2, R611.9.3
332—10Code Requirements for Residential Concrete ConstructionR402.2, R403.1, R404.1.2, R404.1.2.4,
R404.1.4.2, R506.1
530—11Building Code Requirements for Masonry StructuresR301.2.1.1, R318.4, R404.1.1, R606.1, R606.1.1,
R606.2.4, R606.12.1, R606.12.2.2.2, R606.12.2.3.1,
R606.12.3.1, Table R703.4
530.1—11Specification for Masonry StructuresR404.1.1, R606.1, R606.1.1, R606.12.1, R606.12.2.2.1,
R606.12.2.2.2, R606.12.3.1, Table R703.4
ACCAAir Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
TitleReferenced
in code
section number
Manual D—09Residential Duct SystemsM1601.1, M1602.2
Manual J—11Residential Load Calculation—Eighth EditionM1401.3
Manual S—10Residential Equipment SelectionM1401.3
AFPAAmerican Forest and Paper Association (American Wood Council Division)
1111 19th Street, NW, Suite 800
Washington, DC 20036
Standard
reference
number
TitleReferenced
in code
section number
AFPA—2012Span Tables for Joists and RaftersReserved
ANSI/AF&PA
WFCM—2012
Wood Frame Construction Manual for One- and
Two-family Dwellings
R301.1.1, R301.2.1.1,
R602.2, R611.9.2, R611.9.3, R611.10, R614.2.5, R614.3, 1703.3.3, 703.3.4
NDS—2012National Design Specification (NDS) for Wood Construction—
with 2005 Supplement
R404.2.2, R502.2, Table R503.1,
R602.3, R611.9.2, R611.9.3, R802.2
PWF—2007Permanent Wood Foundation Design SpecificationR401.1, R404.2.3
AISIAmerican Iron and Steel Institute
1140 Connecticut Ave, Suite 705
Washington, DC 20036
Standard
reference
number
TitleReferenced
in code
section number
AISI S100—07/S2—10North American Specification for the Design of Cold-formed
Steel Structural Members, with Supplement 2, dated 2010
R505.1.3, R603.6, R611.9.2,
R611.9.3, R804.3.7
AISI S230—07/S2—08Standard for Cold-formed Steel Framing—Prescriptive Method
for One- and Two-family Dwellings, with Supplement 2, dated 2008
R301.1.1, R301.2.1.1, R301.2.2.3.1,
R301.2.2.3.5, R603.6, R603.9.4.1, R603.9.4.2, R611.9.2, R611.9.3, R611.10, R803.2.3, P2603.2,
R606.12.1.1, M1308, M2101.6
AITCAmerican Institute of Timber Construction
7012 S. Revere Parkway, Suite 140
Centennial, CO 80112
Standard
reference
number
TitleReferenced
in code
section number
ANSI/AITC A 190.1—07Structural Glued-laminated TimberR502.1.5, R602.1.2, R802.1.4
ANSIAmerican National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
TitleReferenced
in code
section number
A108.1A—99Installation of Ceramic Tile in the Wet-set Method, with Portland Cement MortarR702.4.1
A108.1B—99Installation of Ceramic Tile, Quarry Tile on a Cured
Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar
R702.4.1
A108.4—99Installation of Ceramic Tile with Organic Adhesives or
Water-Cleanable Tile-setting Epoxy Adhesive
R702.4.1
A108.5—99Installation of Ceramic Tile with Dry-set Portland
Cement Mortar or Latex Portland Cement Mortar
R702.4.1
A108.6—99Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting
and -grouting Epoxy
R702.4.1
A108.11—99Interior Installation of Cementitious Backer UnitsR702.4.1
A118.1—99American National Standard Specifications for Dry-set Portland Cement MortarR702.4.1
A118.3—99American National Standard Specifications for Chemical-resistant,
Water-cleanable Tile-setting and -grouting Epoxy, and
Water-cleanable Tile-setting Epoxy Adhesive
R702.4.1
A118.10—99Specification for Load-bearing, Bonded, Waterproof Membranes for
Thin-set Ceramic Tile and Dimension Stone Installation
P2709.2, P2709.2.4
A136.1—99American National Standard Specifications for Organic Adhesives for Installation of Ceramic TileR702.4.1
A137.1—88American National Standard Specifications for Ceramic TileR702.4.1
A208.1—2009ParticleboardR503.3.1, R605.1
LC1/CSA 6.26—05Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST)G2414.5.3
LC4—07Press-connect Copper and Copper-alloy Fittings for
Use in Fuel Gas Distribution Systems
G2414.10.2
Z21.1—05Household Cooking Gas AppliancesG2447.1
Z21.5.1/CSA 7.1—06Gas Clothes Dryers—Volume I—Type I Clothes DryersG2438.1
Z21.8—94 (R2002)Installation of Domestic Gas Conversion BurnersG2443.1
Z21.10.1/CSA 4.1—09Gas Water Heaters—Volume I—Storage Water Heaters with Input Ratings
of 75,000 Btu per hour or Less
G2448.1
Z21.10.3/CSA 4.3—04Gas Water Heaters—Volume III—Storage Water Heaters with Input Ratings
above 75,000 Btu per hour, Circulating and Instantaneous
G2448.1
Z21.11.2—07Gas-fired Room Heaters—Volume II—Unvented Room HeatersG2445.1
Z21.13/CSA 4.9—10Gas-fired Low-pressure Steam and Hot Water BoilersG2452.1
Z21.15/CSA 9.1—09Manually Operated Gas Valves for Appliances, Appliance
Connector Valves and Hose End Valves
Table G2420.1.1
Z21.22—99 (R2003)Relief Valves for Hot Water Supply Systems—with Addenda Z21.22a—2000 (R2003)
and 21.22b—2001 (R2003)
P2803.2, P2803.7
Z21.24—97Connectors for Gas AppliancesG2422.1
Z21.40.1/CSA 2.91—96 (R2002)Gas-fired, Heat-activated Air-conditioning and Heat Pump AppliancesG2449.1
Z21.40.2/CSA 2.92—96 (R2002)Gas-fired, Work-activated Air-conditioning and Heat
Pump Appliances (Internal Combustion)
G2449.1
Z21.42—93 (R2002)Gas-fired Illuminating AppliancesG2450.1
Z21.47/CSA 2.3—06Gas-fired Central FurnacesG2442.1
Z21.50/CSA 2.22—07Vented Gas FireplacesG2434.1
Z21.56/CSA 4.7—06Gas-fired Pool HeatersG2441.1
Z21.58—95/CSA 1.6—07Outdoor Cooking Gas AppliancesG2447.1
Z21.60/CSA 2.26—03Decorative Gas Appliances for Installation in Solid Fue-burning FireplacesG2432.1
Z21.75/CSA 6.27—07Connectors for Outdoor Gas AppliancesG2422.1
Z21.80—03Line Pressure RegulatorsG2421.1
Z21.83—98Fuel Cell Power PlantsM1903.1
Z21.84—02Manually Listed, Natural Gas Decorative Gas Appliances for Installation in
Solid Fuel-burning Fireplaces—with Addenda Z21.84a —2003
G2432.1, G2432.2
Z21.86—04Gas-fired Vented Space Heating AppliancesG2436.1, G2437.1, G2446.1
Z21.88—02Vented Gas Fireplace Heaters—with Addenda A21.88a—2003 and Z21.88b—2004G2435.1
Z21.91—01Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room HeatersG2445.7.1
Z21.97—09Outdoor Decorative AppliancesG2454.1
Z83.6—90 (R1998)Gas-fired Infrared HeatersG2451.1
Z83.8—02Gas-fired Unit Heaters and Gas-fired Duct Furnaces—with Addenda Z83.8a—2003G2444.1
Z83.19—01 (R2005)Gas-fuel High-intensity Infrared HeatersG2451.1
Z83.20—08Gas-fired Low-intensity Infared Heaters Outdoor Decorative AppliancesG2451.1
Z97.1—09Safety Glazing Materials Used in Buildings—Safety Performance Specifications
and Methods of Test
R308.1.1, R308.3.1
Z124.1—95Plastic Bathtub UnitsTable P2701.1
Z124.2—95Plastic Shower Receptors and Shower StallsTable P2701.1
Z124.3—95Plastic LavatoriesTable P2701.1, P2711.1, P2711.2
Z124.4—96Plastic Water Closet Bowls and TanksTable P2701.1, P2712.1
Z124.6—97Plastic SinksTable P2701.1
APAAPA—The Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
Standard
reference
number
TitleReferenced
in code
section number
ANSI/APA PRP 210—08Standard for Performance-rated Engineered Wood SidingR604.1, Table R703.4
APA E30—03Engineered Wood Construction GuideTable R503.2.1.1(1), R503.2.2,
R803.2.2, R803.2.3
APSPThe Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314
Standard
reference
number
TitleReferenced
in code
section number
ANSI/NSPI 3—99American National Standard for Permanently Installed Residential SpasR4501.6.1
ANSI/APSP/ICC 4—12American National Standard for Above-ground/On-ground Residential Swimming PoolsR4501.6.1
ANSI/APSP/ICC 5—11American National Standard for Residential In-ground Swimming PoolsR4501.6.1
ANSI/APSP/ICC 6—13American National Standard for Residential Portable SpasR4501.6.1
ANSI/APSP 7—06American National Standard for Suction Entrapment Avoidance in Swimming Pools,
Wading Pools, Spas, Hot Tubs and Catch Basins
R4501.6.1, R4501.6.3, R4501.6.6
ASCE/SEIAmerican Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191
Standard
reference
number
TitleReferenced
in code
section number
5—11Building Code Requirements for Masonry StructuresR404.1.1, R606.1, R606.1.1,
R606.12.1, R606.12.2.2.1, R606.12.2.2.2,
R606.12.3.1, Table R703.4
6—11Specification for Masonry StructuresR606.1, R606.1.1,
R606.12.1, R606.12.2.2.1, R606.12.2.2.2,
R606.12.3.1, Table R703.4
7—10Minimum Design Loads for Buildings and Other StructuresR301.2.1.1, R301.2.1.2, R301.2.1.2.1.1,
R301.2.1.5, R301.2.1.5.1, R301.2.1.6, Table R611.6(1),
Table R611.6(2), Table R611.6(3),
Table R611.6(4), Table R611.7(1A), Table R611.7.4, R611.9.2,
R611.9.3, R612.2, R612.4, R615.1, Table R802.11, Table R907.8.1, AH107.4.3
24—05Flood-resistant Design and ConstructionR301.2.4, R301.2.4.1, R322.1,
R322.1.1, R322.1.6, R322.1.9, R322.2.2, R322.3.3.1
32—01Design and Construction of Frost-protected Shallow FoundationsR403.1.4.1
ASHRAEAmerican Society of Heating, Refrigerating
and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
number
TitleReferenced
in code
section number
ASHRAE—2009ASHRAE Handbook of FundamentalsP3001.2, P3101.4, P3103.2
34—2010Designation and Safety Classification of RefrigerantsM1411.1
ASMEAmerican Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
TitleReferenced
in code
section number
ASME/A17.1—2007/CSA B44—2007Safety Code for Elevators and Escalators—with A17.1a/CSA B44a—08 AddendaR321.1
A18.1—2008Safety Standard for Platforms and Stairway Chair LiftsR321.2
A112.1.2—2004Air Gaps in Plumbing SystemsTable P2902.3, P2902.3.1
A112.1.3—2000
(Reaffirmed 2005)
Air Gap Fittings for Use with Plumbing Fixtures, Appliances and AppurtenancesTable P2701.1, P2902.3.1
A112.3.1—2007Stainless Steel Drainage Systems for Sanitary, DWV, Storm
and Vacuum Applications Above and Below Ground
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3,
Table P3302.1
A112.3.4—2000 (R2004)Macerating Toilet Systems and Related ComponentsTable P2701.1, P3007.5
A112.4.1—1993 (R2002)Water Heater Relief Valve Drain TubesP2803.6.1
A112.4.2—2003 (R2008)Water-closet Personal Hygiene DevicesP2722.5
A112.4.3—1999 (R2004)Plastic Fittings for Connecting Water Closets to the Sanitary Drainage SystemP3003.19
A112.6.1M—1997 (R2002)Floor -affixed Supports for Off-the-floor Plumbing Fixtures for Public UseTable P2701.1, P2702.4
A112.6.2—2000 (R2004)Framing-affixed Supports for Off-the-floor Water Closets with Concealed TanksTable P2701.1, P2702.4
A112.6.3—2001 (R2007)Floor and Trench DrainsTable P2701.1
A112.14.1—03
(Reaffirmed 2008)
Backwater ValvesP3008.2
A112.18.1—2005/
CSA B125.1—2010
Plumbing Supply FittingsTable P2701.1, P2708.4,
P2708.5, P2722.1, P2902.2
A112.18.2—2005/
CSA B125.2—2005
Plumbing Waste Fittings with 2007 and 2008 SupplementsTable P2701.1, P2702.2
A112.18.3—2002
(Reaffirmed 2008)
Performance Requirements for Backflow Protection Devices and
Systems in Plumbing Fixture Fittings
P2708.4, P2722.3
A112.18.6/ CSA B125.6—2009Flexible Water ConnectorsP2905.7
A112.19.1M/CSA B45.2—2008Enameled Cast-iron and Enameled Steel Plumbing FixturesTable P2701.1, P2711.1
A112.19.2—2008/CSA B45.1—2008Ceramic Plumbing FixturesTable P2701.1, P2705.1, P2711.1, P2712.1, P2712.2, P2712.9
A112.19.3—2008/CSA B45.4—2008Stainless Steel Plumbing FixturesTable P2701.1, P2705.1, P2711.1, P2712.1
A112.19.4M—1994 (R2004)Porcelain-enameled-formed Steel Plumbing Fixtures—with
1998 and 2000 Supplements
Table P2701.1, P2711.1
A112.19.5/CSA B45.15—2009Trim for Water-closet Bowls, Tanks and UrinalsTable P2701.1
A112.19.7/CSA B45.10—2009Hydromassage Bathtub AppliancesTable P2701.1
A112.19.12—2006Wall-mounted and Pedestal-mounted, Adjustable
and Pivoting Lavatory and Sink Carrier Systems
Table P2701.1, P2711.4, P2714.2
A112.19.15—2005Bathtub/Whirlpool B athtubs with Pressure-sealed DoorsTable P2701.1, P2713.2
B1.20.1—1983 (R2006)Pipe Threads, General-purpose (Inch)G2414.9, P3003.3.3, P3003.5.3,
P3003.10.4, P3003.12.1, P3003.14.3
B16.3—2006Malleable-iron-threaded Fittings, Classes 150 and 300Table P2905.6
B16.4—2006Gray-iron-threaded Fittings Classes, 125 and 250Table P2905.6, Table P3002.3
B16.9—2007Factory-made, Wrought-steel Buttwelding FittingsTable P2905.6
B16.11—2005Forged Fittings, Socket-welding and ThreadedTable P2905.6
B16.12—1998Cast-iron-threaded Drainage FittingsTable P2905.6, Table P3002.3 (R2006)
B16.15—2006Cast-bronze-threaded FittingsTable P2905.6, Table P3002.3
B16.18—2001 (R2005)Cast-copper-alloy Solder Joint Pressure FittingsTable P2905.6, Table P3002.3
B16.22—2001 (R2005)Wrought-copper and Copper-alloy Solder Joint Pressure FittingsTable P2905.6, Table P3002.3
B16.23—2002 (R2006)Cast-copper-alloy Solder Joint Drainage Fittings (DWV)Table P2905.6, Table P3002.3
B16.26—2006Cast-copper-alloy Fittings for Flared Copper TubesTable P2905.6, Table P3002.3
B16.28—1994Wrought-steel Buttwelding Short Radius Elbows and ReturnsTable P2905.6
B16.29—2007Wrought-copper and Wrought-copper -alloy Solder Joint Drainage Fittings (DWV)Table P2905.6, Table P3002.3
B16.33—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in Gas Piping
Systems up to 125 psig (Sizes 1/2 through 2)
Table G2420.1.1
B16.44—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in
Above-ground Piping Systems up to 5 psi
Table G2420.1.1
B 18.6.1—97Wood Screws (Inch Series)R905.7.6.1.2, R905.8.7.1, R904.4.2
B36.10M—2004Welded and Seamless Wrought-steel PipeG2414.4.2
BPVC—2007ASME Boiler and Pressure Vessel Code (2007 Edition)M2001.1.1, G2452.1
CSD-1—2009Controls and Safety Devices for Automatically Fired BoilersM2001.1.1, G2452.1
ASSEAmerican Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
Standard
reference
number
TitleReferenced
in code
section number
1001—2008Performance Requirements for Atmospheric-type Vacuum BreakersTable P2902.3, P2902.3.2
1002—2008Performance Requirements for Anti-siphon Fill Valves for
Water Closet Flush Tank
Table P2701.1, Table P2902.3, P2902.4.1
1003—2009Performance Requirements for Water-pressure-reducing
Valves for Domestic Water Distribution Systems
P2903.3.1
1008—2006Performance Requirements for Plumbing Aspects of
Residential Food Waste Disposer Units
Table P2701.1
1010—2004Performance Requirements for Water Hammer ArrestersP2903.5
1011—2004Performance Requirements for Hose Connection Vacuum BreakersTable P2902.3, P2902.3.2
1012—2009Performance Requirements for Backflow Preventers with Intermediate Atmospheric VentTable P2902.3,
P2902.3.3, P2902.5.1, P2902.5.5
1013—2009Performance Requirements for Reduced Pressure Principle Backflow Preventers
and Reduced Pressure Principle Fire Protection Backflow Preventers
Table P2902.3, P2902.3.5, P2902.5.1, P2902.5.5
1015—2009Performance Requirements for Double Check Backflow Prevention Assemblies
and Double Check Fire Protection Backflow Prevention Assemblies
Table P2902.3, P2902.3.6
1016—2010Performance Requirements for Automatic Compensating
Valves for Individual Showers and Tub/Shower Combinations
Table P2701.1, P2708.3, P2722.2
1017—2010Performance Requirements for Temperature-actuated Mixing Valves for
Hot Water Distribution Systems
P2724.1, P2802.2
1019—2010Performance Requirements for Freeze-resistant, Wall Hydrants,
Vacuum Breaker, Draining Types
Table P2701.1, P2902.3
1020—2004Performance Requirements for Pressure Vacuum Breaker AssemblyTable P2902.3, P2902.3.4
1023—2010Performance Requirements for Hot Water Dispensers, Household storage-type—ElectricalTable P2701.1
1024—2004Performance Requirements for Dual Check Backflow Preventers, Anti-siphon
type, Residential Applications
Table P2902.3
1035—2008Performance Requirements for Laboratory Faucet Backflow PreventersTable P2902.3, P2902.3.2
1037—2010Performance Requirements for Pressurized Flushing Devices (Flushometer) for Plumbing FixturesTable P2701.1
1047—2009Performance Requirements for Reduced Pressure Detector Fire Protection Backflow
Prevention Assemblies
Table P2902.3, P2902.3.5
1048—2009Performance Requirements for Double Check Detector Fire
Protection Backflow Prevention Assemblies
Table P2902.3, P2902.3.6
1050—2009Performance Requirements for Stack Air Admittance Valves for Sanitary
Drainage Systems
P3114.1
1051—2009Performance Requirements for Individual and Branch-type Air Admittance
Valves for Plumbing Drainage Systems
P3114.1
1052—2004Performance Requirements for Hose Connection Backflow PreventersTable P2701.1, Table P2902.3, P2902.3.2
1056—2010Performance Requirements for Spill-resistant Vacuum BreakersTable P2902.3, P2902.3.4
1060—2006Performance Requirements for Outdoor Enclosures for Fluid-conveying ComponentsP2902.6.1
1061—2010Performance Requirements for Removable and Nonremovable Push Fit FittingsTable P2905.6
1062—2006Performance Requirements for Temperature-actuated, Flow Reduction (TAFR)
Valves for Individual Supply Fittings
Table P2701.1, P2724.2
1066—2009Performance Requirements for Individual Pressure Balancing In-line
Valves for Individual Fixture Fittings
P2722.4
1070—2004Performance Requirements for Water-temperature-limiting DevicesP2713.3, P2721.2
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
reference
number
TitleReferenced
in code
section number
A 36/A 36M—08Specification for Carbon Structural SteelR606.15, R611.5.2.2
A 53/A 53M—07Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and SeamlessR402.3,
Table M2101.1, G2414.4.2, Table P2905.4,
Table P2905.5, Table P3002.1(1)
A 90/A 90M—13Text Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or
Zinc-Alloy Cooling—2013
R904.4.3
A 74—09Specification for Cast-iron Soil Pipe and FittingsTable P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3005.2.9, Table P3302.1
A 82/A 82M—05aSpecification for Steel Wire, Plain, for Concrete ReinforcementR606.15
A 106/A 106M—08Specification for Seamless Carbon Steel Pipe for High-temperature Service Table M2101.1, G2414.4.2
A 153/A 153M—05Specification for Zinc Coating (Hot Dip) on Iron and Steel HardwareR317.3, Table R606.15.1
A 167—99 (2009)Specification for Stainless and Heat-resisting Chromium-nickel Steel Plate,
Sheet and Strip
R606.15, Table R606.15.1, R904.4.3
A 240/A 240M—09aStandard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and
Strip for Pressure Vessels and for General Applications
Table R905.4.4
A 254—97 (2007)Specification for Copper Brazed Steel TubingTable M2101.1, G2414.5.1
A 307—07bSpecification for Carbon Steel Bolts and Studs, 60,000 psi Tensile StrengthR611.5.2.2
A 312/A 312M—08aSpecification for Seamless, Welded and Heavily Cold Worked
Austenitic Stainless Steel Pipes
Table P2905.4, Table P2905.5,
Table P2905.6, P2905.12.2
A 463/A 463M—06Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip ProcessTable R905.10.3(2)
A 510—08Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon SteelR606.15
A 539—99Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and
Fuel Oil Lines
M2202.1
A 615/A 615M—09Specification for Deformed and Plain Billet-steel Bars for Concrete
Reinforcement
R402.3.1, R404.1.2.3.7.1, R611.5.2.1
A 641/A 641M—09aSpecification for Zinc-coated (Galvanized) Carbon Steel WireR317.3.1, R505.2.1, Table R606.15.1,
R904.4.1, R904.4.2, R905.7.6.1.2, R905.8.7.1
A 653/A 653M—08Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron Alloy-coated
Galvanized) by the Hot-dip Process
R317.3.1, R505.2.1,
R505.2.3, Table R606.15.1,
R611.5.2.3, Table R905.4.4, M1601.1.1
A 706/A 706M—09Specification for Low-alloy Steel Deformed and Plain Bars for Concrete ReinforcementR402.3.1, R404.1.2.3.7.1, R611.5.2.1
A 755/A 755M—03 (2008)Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and Prepainted
by the Coil-coating Process for Exterior Exposed Building Products
Table R905.4.4
A 778—01Specification for Welded Unannealed Austenitic Stainless Steel
Tubular Products
Table P2905.4, Table P2905.5, Table P2905.6
A 792/A 792M—08Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the
Hot-dip Process
R505.2.1, R505.2.3, R603.2.1,
R603.2.3, R611.5.2.3, R804.2.1,
R804.2.3, Table R905.4.4
A 875/A 875M—06Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip ProcessR611.5.2.3,
Table R905.10.3(2)
A 888—09Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste and Vent Piping Application
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3005.2.9, Table P3302.1
A 924/A 924M—08aStandard Specification for General Requirements for Steel Sheet,
Metallic-coated by the Hot-Dip Process
Table R905.4.4
A 951—06Specification for Steel Wire Masonry Joint ReinforcementR606.15
A 996/A 996M—09Specifications for Rail-steel and Axle-steel Deformed Bars for Concrete ReinforcementTable R404.1.2(9),
R404.1.2.3.7.1,
R611.5.2.1, Table R611.5.4(2)
A 1003/A 1003M—08Standard Specification for Steel Sheet, Carbon, Metallic and Nonmetallic-coated for
Cold-formed Framing Members
R505.2.1, R505.2.3, R603.2.1,
R603.2.3, R804.2.1,
R804.2.3
B 32—08Specification for Solder MetalP3003.10.3, P3003.11.3
B 42—02e01Specification for Seamless Copper Pipe, Standard SizesTable M2101.1,
Table P2905.4, Table P2905.5, Table P3002.1(1)
B 43—98 (2004)Specification for Seamless Red Brass Pipe, Standard Sizes Table M2101.1, G2413.5.2,
Table P2905.4, Table P3002.1(1)
B 75—02Specification for Seamless Copper TubeTable M2101.1, Table P2905.4, Table P2905.5,
Table P3002.1(1), Table P3002.1(2), Table P3002.2
B 88—03Specification for Seamless Copper Water TubeTable M2101.1, G2414.5.2, Table, P2905.4,
Table P2905.5, Table P3002.1(1),
Table P3002.1(2), Table P3002.2
B 101—07Specification for Lead-coated Copper Sheet and Strip for Building ConstructionTable R905.4.4
B 135—08aSpecification for Seamless Brass TubeTable M2101.1
B 209—07Specification for Aluminum and Aluminum-alloy Sheet and PlateTable R905.4.4
B 227—04Specification for Hard-drawn Copper-clad Steel WireR606.15
B 251—02e01Specification for General Requirements for Wrought Seamless Copper and
Copper-alloy Tube
Table M2101.1, Table P2905.4, Table P2905.5,
Table P3002.1(1), Table P3002.2
B 302—07Specification for Threadless Copper Pipe, Standard SizesTable M2101.1, Table P2905.4, Table P2905.5,
Table P3002.1(1)
B 306—09Specification for Copper Drainage Tube (DWV)Table M2101.1, Table P3002.1(1),
Table P3002.1(2), Table P3002.2
B 370—09Specification for Copper Sheet and Strip for Building ConstructionTable R905.4.4, Table P2701.1
B 447—07Specification for Welded Copper TubeTable P2904.4, Table P2905.5
B 695—04Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and SteelR317.3.1, R317.3.3
B 813—00 (2009)Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and
Copper Alloy Tube
Table M2101.1, P2905.14,
P3003.10.3, P3003.11.3
B 828—02Practice for Making Capillary Joints by Soldering of Copper and
Copper Alloy Tube and Fittings
P2905.14, P3003.10.3, P3003.11.3
C 4—04e01Specification for Clay Drain Tile and Perforated Clay Drain TileTable P3302.1
C 5—03Specification for Quicklime for Structural PurposesR702.2.1
C 14—07Specification for Non-reinforced Concrete Sewer, Storm Drain and Culvert PipeTable P3002.2
C 22/C 22M—00 (2005e01)Specification for GypsumR702.2.1, R702.3.1
C 27—98 (2008)Specification for Standard Classification of Fireclay and High-alumina Refractory BrickR1001.5, R1001.8
C 28/C 28M—00 (2005)Specification for Gypsum PlastersR702.2.1
C 33/C 33M—08Specification for Concrete AggregatesR403.4.1
C 34—03Specification for Structural Clay Load-bearing Wall TileTable R301.2(1)
C 35—01(2005)Specification for Inorganic Aggregates for Use in Gypsum PlasterR702.2.1
C 55—06e01Specification for Concrete Building BrickR202, Table R301.2(1)
C 59/C 59M—00 (2006)Specification for Gypsum Casting and Molding PlasterR702.2
C 61/C 61M—00 (2006)Specification for Gypsum Keene's CementR702.2.1
C 62—08Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)R202, Table R301.2(1)
C 73—05Specification for Calcium Silicate Face Brick (Sand Lime Brick)R202, Table R301.2(1)
C 76—08aSpecification for Reinforced Concrete Culvert, Storm Drain and Sewer PipeTable P3002.2
C 90—11bSpecification for Load-bearing Concrete Masonry UnitsTable R301.2(1), R606.5
C 91—05Specification for Masonry CementR702.2.2
C 94/C 94M—09Specification for Ready-mixed ConcreteR404.1.2.3.2, R611.5.1.1
C 129—06Specification for Nonload-bearing Concrete Masonry UnitsTable R301.2(1)
C 143/C 143M—08Test Method for Slump or Hydraulic Cement ConcreteR404.1.2.3.4, R611.5.1.3, R611.6.1
C 145—85Specification for Solid Load-bearing Concrete Masonry UnitsR202, Table R301.2(1)
C 150—07Specification for Portland CementR702.2.2
C 199—84 (2005)Test Method for Pier Test for Refractory MortarR1001.5, R1001.8, R1003.12
C 203—05aStandard Test Methods for Breaking Load and Flexural Properties of Block-type Thermal InsulationTable R613.3.1
C 207—06Specification for Hydrated Lime for Masonry PurposesTable R607.1
C 208—08aSpecification for Cellulosic Fiber Insulating BoardTable R602.3(1), Table R906.2
C 216—07aSpecification for Facing Brick (Solid Masonry Units Made from Clay or Shale)R202, Table R301.2(1)
C 270—08aSpecification for Mortar for Unit MasonryR607.1, AE602
C 272—01 (2007)Standard Test Method for Water Absorption of Core Materials for Structural Sandwich ConstructionsTable R613.3.1
C 273/C 27
3M—07a
Standard Test Method for Shear Properties of Sandwich Core MaterialsTable R613.3.1
C 296—00 (2004)Specification for Asbestos Cement Pressure PipeTable P2905.4
C 315—07Specification for Clay Flue Liners and Chimney Pots R1001.8,
R1003.11.1, Table R1003.14(1),
G2425.12
C 406—06e01Specifications for Roofing SlateR905.6.4
C 411—05Test Method for Hot-surface Performance of High-temperature Thermal InsulationM1601.3
C 425—04Specification for Compression Joints for Vitrified Clay Pipe and FittingsTable P3002.2,
P3003.15, P3003.18
C 428—05 (2006)Specification for Asbestos-cement Nonpressure Sewer PipeTable P3002.2
C 443—05aSpecification for Joints for Concrete Pipe and Manholes, Using Rubber GasketsP3003.7, P3003.18
C 475/C 475—02 (2007)Specification for Joint Compound and Joint Tape for Finishing Gypsum WallboardR702.3.1
C 476—08Specification for Grout for MasonryR609.1.1, R609.1.4
C 508—04Specification for Asbestos-cement Underdrain PipeTable P3302.1
C 514—04Specification for Nails for the Application of Gypsum WallboardR702.3.1
C 552—07Standard Specification for Cellular Glass Thermal InsulationTable R906.2
C 557—03e01Specification for Adhesives for Fastening Gypsum Wallboard to Wood FramingR702.3.1
C 564—08Specification for Rubber Gaskets for Cast Iron Soil Pipe and FittingsP3003.6.2, P3003.6.3, P3003.18
C 578—08bSpecification for Rigid, Cellular Polystyrene Thermal InsulationR403.3, R613.3.1,
R703.11.2.1, Table R906.2
C 587—04Specification for Gypsum Veneer PlasterR702.2.1
C 595—08aSpecification for Blended Hydraulic CementsR702.2.2
C 631—09Specification for Bonding Compounds for Interior Gypsum PlasteringR702.2.1
C 645—08aSpecification for Nonstructural Steel Framing MembersR702.3.3
C 652—09Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)R202, Table R301.2(1)
C 685/C 685M—07Specification for Concrete Made by Volumetric Batching and
Continuous Mixing
R404.1.2.3.2, R611.5.1.1
C 700—07aSpecification for Vitrified Clay Pipe, Extra Strength, Standard Strength and PerforatedTable P3002.2,
Table P3002.3, Table P3302.1
C 728—05Standard Specification for Perlite Thermal Insulation BoardTable R906.2
C 836—06Specification for High Solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane for Use with Separate Wearing Course
R905.15.2
C 843—99 (2006)Specification for Application of Gypsum Veneer PlasterR702.2.1
C 844—04Specification for Application of Gypsum Base to Receive Gypsum Veneer PlasterR702.2.1
C 847—09Specification for Metal LathR702.2.1, R702.2.2
C 887—05Specification for Packaged, Dry, Combined Materials for Surface Bonding MortarR406.1
C 897—05Specification for Aggregate for Job-mixed Portland Cement-based PlastersR702.2.2
C 920—08Standard Specification for Elastomeric Joint SealantsR406.4.1, R703.8
C 926—11aSpecification for Application of Portland Cement-based PlasterR202, R702.2.2, R702.2.2.1, R703.6,
R703.6.2.1, R703.6.4
C 933—07bSpecification for Welded Wire LathR702.2.1, R702.2.2
C 954—07Specification for Steel Drill Screws for the Application of Gypsum Panel Products or
Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or
to 0.112 in. (2.84 mm) in Thickness
R505.2.4, R603.2.4, R702.3.6, R804.2.4
C 955—09Specification for Load-bearing (Transverse and Axial) Steel Studs, Runners (Tracks), and Bracing or
Bridging for Screw Application of Gypsum Panel Products and Metal Plaster Bases
R702.3.3
C 957—06Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing
Membrane for Use with Integral Wearing Surface
R905.15.2
C 1002—07Specification for Steel Drill Screws for the Application of Gypsum Panel
Products or Metal Plaster Bases
R702.3.1, R702.3.6
C 1029—08Specification for Spray-applied Rigid Cellular Polyurethane Thermal InsulationR905.14.2
C 1032—06Specification for Woven Wire Plaster BaseR702.2.1, R702.2.2
C 1047—09Specification for Accessories for Gypsum Wallboard and Gypsum Veneer BaseR702.2.1, R702.2.2, R702.3.1
C 1063—12aSpecification for Installation of Lathing and Furring to Receive Interior
and Exterior Portland Cement-based Plaster
R702.2.2, R703.6
C 1107/C 1107M—08Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink)R402.3.1
C 1116/C 116M—08aStandard Specification for Fiber-reinforced Concrete and ShotcreteR402.3.1
C 1167—03Specification for Clay Roof TilesR905.3.4
C 1173—08Specification for Flexible Transition Couplings for Underground Piping SystemsP3003.3, P3003.7, P3003.8.1,
P3003.14.1, P3003.15,
P3003.17.2, P3003.18
C 1177/C 1177M—08Specification for Glass Mat Gypsum Substrate for Use as SheathingR702.3.1
C 1178/C 1178M—08Specification for Glass Mat Water-resistant Gypsum Backing PanelR702.3.1, R702.3.8, R702.4.2
C 1186—08Specification for Flat Nonasbestos Fiber Cement SheetsR703.10.1, R703.10.2
C 1261—07Specification for Firebox Brick for Residential FireplacesR1001.5, R1001.8
C 1277—08Specification for Shielded Couplings Joining Hubless Cast Iron Soil Pipe and FittingsP3003.6.3
C 1278/C 1278M—07aSpecification for Fiber-reinforced Gypsum PanelsR702.3.1, R702.3.8, R702.4.2
C 1281—03Standard Specification for Preformed Tape Sealants for Glazing ApplicationsR703.8
C 1283—07aPractice for Installing Clay Flue LiningR1003.9.1, R1003.12
C 1288—99 (2004)e1Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate SheetsR702.4.2
C 1289—08Standard Specification for Faced Rigid Cellular Polyisocyanurate
Thermal Insulation Board
R703.11.2.1, Table R906.2
C 1325—08bStandard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior
Substrate Sheets
R702.4.2
C 1328—05Specification for Plastic (Stucco) CementR702.2.2
C 1396/C 1396M—06aSpecification for Gypsum BoardTable R602.3(1), R702.2.1, R702.2.2, R702.3.1, R702.3.8
C 1440—08Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste
and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
P3003.18
C 1460—08Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above GroundP3003.18
C 1461—08Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for
Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and
Below Ground Use
P3003.18
C 1492—03Specification for Concrete Roof TileR905.3.5
C 1513—04Standard Specification for Steel Tapping Screws for Cold-formed
Steel Framing Connections
R505.2.4, R603.2.4, R702.3.6, R804.2.4
C 1658/C 1658M—06Standard Specification for Glass Mat Gypsum PanelsR702.3.1
D 41—05Specification for Asphalt Primer Used in Roofing, Dampproofing and WaterproofingTable R905.9.2, Table R905.11.2
D 43—00(2006)Specification for Coal Tar Primer Used in Roofing, Dampproofing and WaterproofingTable R905.9.2
D 225—07Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral GranulesR905.2.4
D 226—06Specification for Asphalt-saturated (Organic Felt) Used in Roofing and WaterproofingR703.2, R905.2.3,
R905.2.7, R905.3.3, R905.4.3, R905.4.3.3,
R905.5.3, R905.5.3.3, R905.6.3,
R905.6.3.3, R905.7.3.3, Table R905.7.5, R905.8.3, R905.8.3.3, R905.8.3.4,
R905.8.10.1, Table R905.9.2, R905.10.5, R905.10.5.2, R907.7.2
D 227—03Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and WaterproofingTable R905.9.2
D 312—00 (2006)Specification for Asphalt Used in RoofingTable R905.9.2
D 422—63 (2007)Test Method for Particle-size Analysis of SoilsR403.1.8.1
D 449—03 (2008)Specification for Asphalt Used in Dampproofing and WaterproofingR406.2
D 450—07Specification for Coal-tar Pitch Used in Roofing, Dampproofing and WaterproofingTable R905.9.2
D 1227—95 (2007)Specification for Emulsified Asphalt Used as a Protective
Coating for Roofing
Table R905.9.2,
Table R905.11.2, R905.15.2
D 1248—05Specification for Polyethylene Plastics Extrusion Materials for Wire and CableM1601.1.2
D 1527—99 (2005)Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe, Schedules 40 and 80Table P2905.4
D 1621—04aStandard Test Method for Compressive Properties of Rigid Cellular PlasticsTable R613.3.1
D 1622—08Standard Test Method for Apparent Density of Rigid Cellular PlasticsTable R613.3.1
D 1623—03Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid
Cellular Plastics
Table R613.3.1
D 1693—08Test Method for Environmental Stress-cracking of Ethylene PlasticsTable M2101.1
D 1784—08Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds
and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds
M1601.1.2
D 1785—06Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120Table P2905.4
D 1863—05Specification for Mineral Aggregate Used in Built-up RoofsTable R905.9.2
D 1869—95 (2005)e1Specification for Rubber Rings for Asbestos-cement PipeP2904.17, P3003.4, P3003.18
D 1970—09Specification for Self-adhering Polymer Modified Bitumen Sheet Materials
Used as Steep Roofing Underlayment for Ice Dam Protection
R905.2.3, R905.2.7, R905.2.8.2,
R905.3.3, R905.4.3, R905.4.3.3, R905.6.3,
R905.6.3.3, R905.10.5, R905.10.5.2, R907.7.2
D 2104—03Specification for Polyethylene (PE) Plastic Pipe, Schedule 40Table P2905.4
D 2126—04Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid AgingTable R613.3.1
D 2178—04Specification for Asphalt Glass Felt Used in Roofing and WaterproofingTable R905.9.2
D 2235—04Specification for Solvent Cement for Acrylonitrile-butadiene-styrene (ABS) Plastic
Pipe and Fittings
P2905.9.1.1,
P3003.3.2, P3003.8.2
D 2239—03Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled
Inside Diameter
Table P2905.4
D 2241—05Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)Table P2905.4
D 2282—05Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (SDR-PR)Table P2905.4
D 2412—02 (2008)Test Method for Determination of External Loading Characteristics of Plastic Pipe by
Parallel-plate Loading
M1601.1.2
D 2447—03Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80, Based on
Outside Diameter
Table M2101.1
D 2464—06Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80Table P2905.6
D 2466—06Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40Table P2905.6
D 2467—06Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80Table P2905.6
D 2468—96aSpecification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe Fittings, Schedule 40Table P2905.6
D 2513—08bSpecification for Thermoplastic Gas Pressure Pipe, Tubing and FittingsTable M2101.1, M2104.2.1.3,
G2414.6, G2414.6.1, G2414.11, G2415.15.2
D 2559—04Standard Specification for Adhesives for Structural Laminated Wood Products for
Use Under Exterior (West Use) Exposure Conditions
R613.3.3
D 2564—04e01Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC)
Plastic Piping Systems
P2905.9.1.3, Table P3002.2,
P3003.9.2, P3003.14.2
D 2609—02 (2008)Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic PipeTable P2905.6
D 2626—04Specification for Asphalt-saturated and Coated Organic Felt Base
Sheet Used in Roofing
R905.3.3, Table R905.9.2
D 2657—07Standard Practice for Heat Fusion-joining of Polyolefin Pipe FittingsP2905.3.1, P3003.17.1
D 2661—08Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain, Waste,
and Vent Pipe and Fittings
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.3.2, P3003.8.2
D 2665—09Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste and Vent
Pipe and Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3
D 2672—96a (2003)Specification for Joints for IPS PVC Pipe Using Solvent CementTable P2905.4
D 2683—04Specification for Socket-type Polyethylene Fittings for Outside
Diameter-controlled Polyethylene Pipe and Tubing
Table M2101.1, M2104.2.1.1
D 2729—04E01Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and FittingsTable P3302.1,
Table AO103.10
D 2737—03Specification for Polyethylene (PE) Plastic TubingTable P2905.4
D 2751—05Specification for Acrylonitrile-butadiene-styrene (ABS) Sewer Pipe and FittingsTable P3002.2,
Table P3002.3
D 2822—05Specification for Asphalt Roof Cement, Asbestos ContainingTable R905.9.2
D 2823—05Specification for Asphalt Roof Coatings, Asbestos ContainingTable R905.9.2
D 2824—06Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered,
Asbestos Fibered and Fibered without Asbestos
Table R905.9.2, Table R905.11.2
D 2837—08Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials
or Pressure Design Basis for Thermoplastic Pipe Products
Table M2101.1
D 2846/D 2846M—09Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic
Hot- and Cold-water Distribution Systems
Table M2101.1, P2904.9.1.2,
Table P2905.4,
Table P2905.5, Table P2905.6
D 2855—96 (2002)Standard Practice for Making Solvent-cemented Joints with Poly
(Vinyl Chloride) (PVC) Pipe and Fittings
P3003.9.2, P3003.14.2
D 2898—04Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for
Fire Testing
R802.1.3.4, R802.1.3.6
D 2949—01a (2008)Specification for 3.25-in. Outside Diameter Poly (Vinyl Chloride)
(PVC) Plastic Drain, Waste and Vent Pipe and Fittings
Table P3002.1(1),
Table P3002.1(2), Table P3002.2, Table P3002.3
D 3019—08Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered,
Asbestos Fibered and Nonasbestos Fibered
Table R905.9.2, Table R905.11.2
D 3034—08Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and FittingsTable P3002.2,
Table P3002.3
D 3035—08Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based On Controlled Outside DiameterTable M2101.1
D 3161—09Test Method for Wind Resistance of Asphalt Shingles (Fan Induced Method)R905.2.4.1,
Table R905.2.4.1(2), R905.2.6.1, R905.16.3
D 3201—08aTest Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base ProductsR802.1.3.7
D 3212—07Specification for Joints for Drain and Sewer Plastic Pipes
Using Flexible Elastomeric Seals
P3003.3.1, P3003.8.1,
P3003.9.1, P3003.14.1,
P3003.17.2
D 3309—96a (2002)Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution SystemTable M2101.1
D 3311—08Specification for Drain, Waste and Vent (DWV) Plastic Fittings PatternsP3002.3
D 3350—08Specification for Polyethylene Plastic Pipe and Fitting MaterialsTable M2101.1
D 3462—09Specification for Asphalt Shingles Made From Glass Felt and Surfaced with Mineral GranulesR905.2.4
D 3468—99 (2006)e01Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene Used in
Roofing and Waterproofing
R905.15.2
D 3787—01Testing Method for Busting Strength of Textiles, Constant Rate of Traverse (CRT)
Ball Burst Test
R4501.17.1.15
D 3679—09Specification for Rigid Poly (Vinyl Chloride) (PVC) SidingTable R703.4, R703.11
D 3737—08Practice for Establishing Allowable Properties for Structural Glued
Laminated Timber (Glulam)
R502.1.5, R602.1.2, R802.1.4
D 3747—79 (2007)Specification for Emulsified Asphalt Adhesive for Adhering Roof InsulationTable R905.9.2, Table R905.11.2
D 3909—97b (2004)e1Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral GranulesR905.2.8.2,
R905.5.4, Table R905.9.2
D 3957—06Standard Practices for Establishing Stress Grades for Structural Members Used in Log BuildingsR502.1.6,
R602.1.3, R802.1.5
D 4022—07Specification for Coal Tar Roof Cement, Asbestos ContainingTable R905.9.2
D 4068—01Specification for Chlorinated Polyethylene (CPE) Sheeting for Concealed Water
Containment Membrane
P2709.2, P2709.2.2
D 4318—05Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of SoilsR403.1.8.1
D 4434/D 4434M—09Specification for Poly (Vinyl Chloride) Sheet RoofingR905.13.2
D 4479—07Specification for Asphalt Roof Coatings-asbestos-freeTable R905.9.2
D 4551—96 (2008)e1Specification for Poly (Vinyl) Chloride (PVC) Plastic Flexible Concealed
Water-containment Membrane
P2709.2, P2709.2.1
D 4586—07Specification for Asphalt Roof Cement-asbestos-freeTable R905.9.2
D 4601—08Specification for Asphalt-coated Glass Fiber Base Sheet Used in RoofingTable R905.9.2
D 4637—08Specification for EPDM Sheet Used in Single-ply Roof MembraneR905.12.2
D 4829—08aTest Method for Expansion Index of SoilsR403.1.8.1
D 4869—05e01Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep
Slope Roofing
R905.2.3, R905.2.7.2, R905.4.3, R905.4.3.3,
R905.5.3, R905.5.3.3, R905.6.3, R905.6.3.3,
R905.7.3, R905.7.3.3, R905.8.3, R905.8.3.3,
R905.10.5, R907.7.2
D 4897—01Specification for Asphalt Coated Glass-fiber Venting Base Sheet Used in RoofingTable R905.9.2
D 4990—97a (2005)e01Specification for Coal Tar Glass Felt Used in Roofing and WaterproofingTable R905.9.2
D 5019—07aSpecification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing MembraneR905.12.2
D 5034—95Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) Specifications
for Adhesives for Field Gluing Plywood to Lumber Framing for Floor Systems
R4501.17.1.15
D 5055—09Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joistsR502.1.4
D 5456—09Standard Specification for Evaluation of Structural
Composite Lumber Products
R502.1.8, R602.14, R802.1.6
D 5516—03Test Method for Evaluating the Flexural Properties of Fire-retardant-treated Softwood
Plywood Exposed to the Elevated Temperatures
R802.1.3.5.1
D 5643—06Specification for Coal Tar Roof Cement Asbestos-freeTable R905.9.2
D 5664—08Test Methods For Evaluating the Effects of Fire-retardant Treatments
and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber
R802.1.3.5.2
D 5665—99a (2006)Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and WaterproofingTable R905.9.2
D 5726—98 (2005)Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and WaterproofingTable R905.9.2
D 6083—05e01Specification for Liquid-applied Acrylic Coating Used in RoofingTable R905.9.2, Table R905.11.2,
Table R905.14.3, R905.15.2
D 6162—00a (2008)Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials
Using a Combination of Polyester and Glass Fiber Reinforcements
Table R905.11.2
D 6163—00 (2008)Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials
Using Glass Fiber Reinforcements
Table R905.11.2
D 6164—05e1Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials
Using Polyester Reinforcements
Table R905.11.2
D 6222—08Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials
Using Polyester Reinforcements
Table R905.11.2
D 6223—02Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials
Using a Combination of Polyester and Glass Fiber Reinforcement
Table R905.11.2
D 6298—05e1Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS) Modified
Bituminous Sheets with a Factory Applied Metal Surface
Table R905.11.2
D 6305—08Practice for Calculating Bending Strength Design Adjustment Factors
for Fire-retardant-treated Plywood Roof Sheathing
R802.1.3.5.1
D 6380—03 (2009)Standard Specification for Asphalt Roll Roofing (Organic Felt)R905.2.8.2, R905.3.3, R905.5.4
D 6509-00Specification for Atactic Polypropylene (APP) Modified Bituminous Base Sheet Materials
Using Glass Fiber Reinforcements
Table R905.11.2
D 6694—08Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing SystemsTable R905.14.3, R905.15.2
D 6754—02Standard Specification for Ketone-ethylene-ester-based Sheet RoofingR905.13.2
D 6757—07Standard Specification for Inorganic Underlayment for Use with Steep Slope
Roofing Products
R905.2.3, R905.2.7.2. R905.4.3, R905.4.3.3, R905.2.7,
R905.5.3, R905.5.3.3, R905.6.3, R905.6.3.3, R905.10.5, R905.10.5.2,
D 6841—08Standard Practice for Calculating Design Value Treatment Adjustment Factors
for Fire-retardant-treated Lumber
R802.1.3.5.2
D 6878—08e1Standard Specification for Thermoplastic-polyolefin-based Sheet RoofingR905.13.2
D 6947—07Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating
Used in Spray Polyurethane Foam Roofing System
Table R905.14.3, R905.15.2
D 7032—08Standard Specification for Establishing Performance Ratings for Wood-plastic Composite
Deck Boards and Guardrail Systems (Guards or Handrails)
R317.4, R317.4.1, R507.3
D 7158—08dStandard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift Force/
Uplift Resistance Method)
R905.2.6.1, Table R905.2.6.1
E 84—09Test Method for Surface Burning Characteristics
of Building Materials
R202, R302.9.3, R302.9.4,
R302.10.1, R302.10.2, R316.3,
R316.4, R316.5.9, R316.5.11,
R802.1.3, M1601.3, M1601.5.2
E 90—04Test Method for Laboratory Measurement of Airborne Sound Transmission
Loss of Building Partitions and Elements
AK102, AK102.1.1
E 96/E 96M—05Test Method for Water Vapor Transmission of MaterialsR202, Table R613.3.1,
M1411.5, M1601.4.5
E 108—07aTest Methods for Fire Tests of Roof CoveringsR902.1
E 119—08aTest Methods for Fire Tests of Building Construction and MaterialsR302.2, R302.3,
R302.4.1, R316.4
E 136—09Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°CR202, Table R302.1(1),
Table R302.1(2), R302.11
E 330—02Test Method for Structural Performance of Exterior Windows, Curtain Walls and
Doors by Uniform Static Air Pressure Difference
R612.4, R612.5, R703.1.2
E 331—00 (2009)Test Method for Water Penetration of Exterior Windows, Skylights, Doors
and Curtain Walls by Uniform Static Air Pressure Difference
R703.1.1
E 492—09Specification for Laboratory Measurement of Impact Sound Transmission through
Floor-ceiling Assemblies Using the Tapping Machine
AK103
E 814—08bTest Method for Fire Tests of Through-penetration FirestopsR302.4.1.2
E 970—08aTest Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant
Heat Energy Source
R302.10.5
E 1300—04e01, 07e01 or 09aPractice for Determining Load Resistance of Glass in BuildingsR612.3
E 1509—04Standard Specification for Room Heaters, Pellet Fuel-burning TypeM1410.1
E 1602—03Guide for Construction of Solid Fuel Burning Masonry HeatersR1002.2
E 1886—02 or 05Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters
Impacted by Missles and Exposed to Cyclic Pressure Differentials
R301.2.1.2, R301.2.1.2.1.1, R612.3.1, R612.6.1
E 1996—02, 05, 06, 09 or 12Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors
and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
R301.2.1.2, R301.2.1.2.1, R612.3.1, R612.6.1
E 2178—03Standard Test Method for Air Permeance of Building MaterialsR202
E 2231—04Standard Practice for Specimen Preparation and Mounting of Pipe and Duct
Insulation Materials to Assess Surface Burning Characteristics
M1601.3
E 2273—03Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation
and Finish Systems (EIFS) Clad Wall Assemblies
R703.9.2
E 2568—09e1Standard Specification for PB Exterior Insulation and Finish Systems (EIFS)R703.9.1, R703.9.2
E 2570—07Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings Used Under
Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
R703.9.2.1
E 2634—08Standard Specification for Flat Wall Insulating Concrete Form (ICF) SystemsR404.1.2.3.6.1, R611.4.4
F 405—05Specification for Corrugated Polyethylene (PE) Tubing and FittingsTable P3302.1,
F 409—02(2008)Specification for Thermoplastic Accessible and Replaceable Plastic Tube and
Tubular Fittings
Table P2701.1, P2702.2, P2702.3
F 437—06Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80Table P2905.6
F 438—04Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40Table P2905.6
F 439—06Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80Table P2905.6
F 441/F 441M—02 (2008)Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80Table P2905.4, Table P2905.5
F 442/F 442M—99 (2005)e1Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)Table P2905.4, Table P2905.5
F 477—08Specification for Elastomeric Seals (Gaskets) for Joining Plastic PipeP2905.17, P3003.18
F 493—04Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and FittingsP2905.9.1.2
F 628—08Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain, Waste and Vent Pipe with a Cellular CoreTable P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3002.3, P3003.3.2, P3003.8.2
F 656—08Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and FittingsP2905.9.1.3,P3003.9.2, P3003.14.2
F 714—08Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside DiameterTable P3002.2
F 876—08bSpecification for Cross-linked Polyethylene (PEX) TubingTable M2101.1, Table P2905.4, Table P2905.5
F 877—07Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution SystemsTable M2101.1, Table P2905.4, Table P2905.5, Table P2905.6
F 891—07Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular CoreP2905.6, Table P3002.1(1), Table P3002.1(2), Table P3002.2, Table P3302.1
F 1055—98 (2006)Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and TubingTable M2101.1, M2104.2.1.2
F 1281—07Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Pressure PipeTable M2101.1, Table P2905.4, Table P2905.5, Table P2905.6, P2505.11.1
F 1282—06Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure PipeTable M2101.1, Table P2905.4, Table P2905.5, Table P2905.6, P2905.11.1
F 1346—91 (2003)Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot TubsR4501.2, R4501.17
F 1412—09Specification for Polyolefin Pipe and Fittings for Corrosive Waste DrainageTable P3002.1(2), Table P3002.2, Table P3002.3, P3003.16.1
F 1554—07aSpecification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield StrengthR611.5.2.2
F 1667—05Specification for Driven Fasteners, Nails, Spikes and StaplesTable R703.4, R904.4.1, R905.2.5
F 1807—08Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) TubingTable M2101.1, Table P2905.6
F 1866—07Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated FittingsTable P3002.3
F 1960—09Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) TubingTable M2101.1, Table P2905.6
F 1973—08Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution SystemsG2415.15.2
F 1974—08Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe P2505.11.1, Table P2905.6
F 1986—01 (2006)Multilayer Pipe Type 2, Compression Joints for Hot and Cold Drinking Water SystemsTable P2905.4, Table P2905.5, Table P2905.6
F 2080—08Specification for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) PipeP2905.6
F 2090—08Specification for Window Fall Prevention Devices—with Emergency Escape (Egress) Release MechanismsR612.2, R612.3
F 2098—08Standard Specification for Stainless Steel Clamps for SDR9 PEX Tubing to Metal Insert FittingsTable M2101.1, Table P2905.6
F 2159—08Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) TubingP2905.6
F 2200—05Standard Specification for Automated Vehicular Gate ConstructionAO103.1
F 2262—05Standard Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9Table P2905.4, Table P2905.5
F 2389—07e1Standard for Pressure-rated Polypropylene (PP) Piping SystemsTable M2101.1, Table P2905.4, Table P2905.5, Table P2905.6, P2905.10.1
F 2434—08Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) TubingTable P2905.6
F 2623—08Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDRG TubingTable M2101.1
F 2735—09Standard Specification for SDR9 Cross-linked Polyethylene (PEX) and Raised Temperature (PE-RT) TubingTable 605.3, Table 605.4, Table M2101.1
F 2769—09Polyethylene or Raised Temperature (PE-RT) Plastic Hot and Cold-Water Tubing and Distribution SystemsTable M2101.1, Table P2905.4
G 53—96Practice for Operating Light and Water Exposure Apparatus (Fluorescent UV Condensation
Type) for Exposure of Nonmetallic Materials
R4501.17.1.15
AWPAAmerican Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
Standard
reference
number
TitleReferenced
in code
section number
C1—03All Timber Products—Preservative Treatment by Pressure ProcessesR902.2
M4—08Standard for the Care of Preservative-treated Wood ProductsR317.1.1, R318.1.2
U1—11USE CATEGORY SYSTEM: User Specification for Treated Wood
Except Section 6 Commodity Specification H
R317.1, R322.1.8, R402.1.2,
R504.3, Table R905.8.5
AWSAmerican Welding Society
550 N. W. LeJeune Road
Miami, FL 33126
Standard
reference
number
TitleReferenced
in code
section number
A5.8—04Specifications for Filler Metals for Brazing and Braze WeldingP3003.5.1, P3003.10.1, P3003.11.1
AWWAAmerican Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
TitleReferenced
in code
section number
C104—98Standard for Cement-mortar Lining for Ductile-iron Pipe and Fittings for WaterP2905.4
C110/A21.10—03Standard for Ductile-iron and Gray-iron Fittings, 3 Inches through 48 Inches, for WaterTable P2905.6,
Table P3002.3
C115/A21.15—99Standard for Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron
Threaded Flanges
Table P2905.4
C151/A21.51—02Standard for Ductile-iron Pipe, Centrifugally Cast, for WaterTable P2905.4
C153/A21.53—00Standard for Ductile-iron Compact Fittings for Water ServiceTable P2905.6
C510—00Double Check Valve Backflow Prevention AssemblyTable P2902.3, P2902.3.6
C511—00Reduced-pressure Principle Backflow Prevention AssemblyTable P2902.3,
P2902.3.5, P2902.5.1
C901—08Polyethylene (PE) Pressure Pipe and Tubing 1/2 in. (13 mm)
through 3 in. (76 mm) for Water Service
P2905.4
C904—06Cross-Linked Polyethylene (PEX) Pressure Pipe, 1/2 in. (12 mm) through 3 in. (76 mm)
for Water Service
P2905.4
CGSBCanadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
Standard
reference
number
TitleReferenced
in code
section number
CAN/CGSB-37.54—95Polyvinyl Chloride Roofing and Waterproofing MembraneR905.13.2
37-GP-52M—(1984)Roofing and Waterproofing Membrane, Sheet Applied, ElastomericR905.12.2
37-GP-56M—(1980)Membrane, Modified Bituminous, Prefabricated and Reinforced for Roofing—with December 1985 AmendmentTable R905.11.2
CISPICast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga, TN 37421
Standard
reference
number
TitleReferenced
in code
section number
301—04aStandard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste and Vent Piping Applications
Table P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3005.2.9, Table P3302.1
310—04Standard Specification for Coupling for Use in Connection with Hubless
Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain,
Waste and Vent Piping Applications
P3003.6.3
CPAComposite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
Standard
reference
number
TitleReferenced
in code
section number
ANSI A135.4—04Basic HardboardTable R602.3(2)
ANSI A135.5—04Prefinished Hardboard PanelingR702.5
ANSI A135.6—06Hardboard SidingTable R703.4
CPSCConsumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
Standard
reference
number
TitleReferenced
in code
section number
16 CFR, Part 1201—(2002)Safety Standard for Architectural GlazingR308.1.1, R308.3.1, Table R308.3.1(1)
16 CFR, Part 1209—(2002)Interim Safety Standard for Cellulose InsulationR302.10.3
16 CFR, Part 1404—(2002)Cellulose InsulationR302.10.3
CSACanadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4N 5N6
Standard
reference
number
TitleReferenced
in code
section number
ANSI/CSA AmericaStationary Fuel Cell Power SystemsM1903.1
FCI—03
ANSI Z21.56/CSA 4.7—06
Gas-Fired Pool HeatersG2441.1
ASME A112.18.1/
CSA B125.1—2005
Plumbing Supply FittingsP2708.4, P2722.1, P2722.2, P2722.3
ASME A112.18.2/
CSA B125.2—05
Plumbing Waste FittingsTable P2701.1, P2702.2
ASME A112.19.2/
CSA B45.1—08
Ceramic Plumbing FixturesTable P2701.1, P2711.1, P2712.1
ASME A112.19.1/
CSA B45.2—02
Enameled Cast-Iron and Enameled Steel Plumbing FixturesTable 2701.1, P2711.1
ASME A112.19.3—2008/
CSA B45.4—2008
Stainless Steel Plumbing FixturesTable P2701.1, P2705.1, P2711.1, P2712.1
A112.19.5/
CSA B45.15—2009
Trim for Water-closet Bowls, Tanks and UrinalsTable P2701.1
CSA 8—93Requirements for Gas Fired Log Lighters for Wood Burning Fireplaces—
with revisions through January 1999
G2433.1
O325—07Construction SheathingR503.2.1, R602.3, R604.1, R903.2.1
O437-Series—93Standards on OSB and Waferboard (Reaffirmed 2006)R503.2.1, R602.3, R604.1, R803.2.1
CAN/CSA A257.1M—92Circular Concrete Culvert, Storm Drain, Sewer Pipe and FittingsTable P3002.2
CAN/CSA A257.2M—92Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and FittingsTable P3002.2
CAN/CSA A257.3M—92Joints for Circular Concrete Sewer and Culvert Pipe,
Manhole Sections and Fittings Using Rubber Gaskets
P3003.7, P3003.18
CAN/CSA B64.1.1—01Vacuum Breakers, Atmospheric Type (AVB)Table P2902.2, P2902.3.2
CAN/CSA B64.2—01Vacuum Breakers, Hose Connection Type (HCVP)Table P2902.2, P2902.3.2
CAN/CSA B64.2.2—01Vacuum Breakers, Hose Connection Type (HCVP) with
Automatic Draining Feature
Table P2902.2, P2902.3.2
CAN/CSA B64.3—01Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP)Table P2902.2, P2902.3.3
CAN/CSA B64.4—01Backflow Preventers, Reduced Pressure Principle Type (RP)Table P2902.3,
101/I.S.2/A440—08Specifications for Windows, Doors and Unit SkylightsR308.6.9, R612.6
B45.5—02 (R2008)Plastic Plumbing FixturesTable P2701.1, P2711.2, P2712.1
B45.9—99 (R2008)Macerating Systems and Related ComponentsP3007.1, P3007.2.1, P3007.5
B64.1.2—07Pressure Vacuum Breakers (PVB)Table P2902.2, P2902.3.4
B64.1.3—07Spill Resistant Pressure Vacuum Breakers (SRPVB)P2902.3
B64.2.1—07Hose Connection Vacuum Breakers (HCVB)
with Manual Draining Feature
Table P2902.2, P2902.3.2
B64.2.1.1—07Hose Connection Dual Check Vacuum Breakers (HCDVB)Table P2902.2, P2902.3.2
B64.3—07Dual Check Backflow Preventers with Atmospheric Port (DCAP)Table P2902.2
B64.4.1—07Reduced Pressure Principle for Fire Sprinklers (RPF)Table P2902.2
B64.5—07 Double Check Backflow Preventers (DCVA)Table P2902.2, P2902.3.6
B64.5.1—07Double Check Valve Backflow Preventers,
Type for Fire Systems (DCVAF)
Table P2902.2, P2902.3.6
B64.6—07Dual Check Valve Backflow Preventers (DuCTable P2902.3
B64.7—07Laboratory Faucet Vacuum Breakers (LFVB)Table P2902.2, P2902.3.2
B125.1—01Plumbing FittingsTable P2701.1, P2708.3, P2722.2, P2722.3
B125.3—05Plumbing FittingsTable 2701.1, P2713.3, P2721.2
B137.1—05Polyethylene (PE) Pipe, Tubing and Fittings for
Cold Water Pressure Services
Table P2905.4, Table P2905.6
B137.2—05Polyvinylchloride PVC Injection-moulded Gasketed Fittings for
Pressure Applications
Table P2905.6
B137.3—05Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure ApplicationsTable P2905.4, P3003.9.2,
P3003.14.2
B137.5—05Cross-linked Polyethylene (PEX) Tubing Systems for Pressure ApplicationsTable P2905.4,
Table P2905.5, Table P2905.6
B137.6—05Chlorinated polyvinylchloride CPVC Pipe, Tubing and Fittings For Hot- and
Cold-water Distribution Systems
Table P2905.4,
Table P2905.5, Table 2905.6
B137.9—05Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe Systems
P2505.11.1, Table P2905.4
B137.10M—05Cross-linked Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe Systems
Table M2101.1, P2505.11.1,
Table P2905.4, Table P2905.5
B137.11—05 Polypropylene (PP-R) Pipe and Fittings for Pressure ApplicationsTable P2905.4.1, Table 2905.4,
Table P2905.6
B181.1—06Acrylonitrile-butadiene-styrene (ABS) Drain, Waste and Vent Pipe
and Pipe Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3003.3.2, P3003.8.2
B181.2—06Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC)
Drain, Waste and Vent Pipe and Pipe Fittings
Table P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, P3003.9.2, P3003.14.2,
P3008.2, Table P3302.1
B181.3—06 Polyolefin and polyvinylidene (PVDF) Laboratory Drainage SystemsTable P3002.1(1),
Table P3002.1(2), Table P3002.2,
Table P3002.3, P3003.16.1
B182.2—06PSM Type polyvinylchloride (PVC) Sewer Pipe and FittingsTable P3002.1(1), Table P3002.1(2),
Table P3002.2, Table P3002.3, Table P3302.1
B182.4—06Profile polyvinylchloride (PVC) Sewer Pipe & FittingsTable P3002.2,
Table P3002.3, Table P3302.1
B182.6—06Profile Polyethylene Sewer Pipe and FittingsTable P3302.1
B182.8—06Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and FittingsTable P3302.1
B356—00Water Pressure Reducing Valves for Domestic Water Supply SystemsP2903.3.1
B483.1—07Drinking Water Treatment SystemsP2908.1, P2908.2
B602—05Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer PipeP3003.3.1, P3003.6.3,
P3003.7, P3003.8.1, P3003.14.1, P3003.15, P3003.17.2
LC3—00Appliance Stands and Drain PansP2801.5, P2902.3.5, P2902.5.1
CSSBCedar Shake & Shingle Bureau
P. O. Box 1178
Sumas, WA 98295-1178
Standard
reference
number
TitleReferenced
in code
section number
CSSB—97Grading and Packing Rules for Western Red Cedar Shakes and Western
Red Shingles of the Cedar Shake and Shingle Bureau
R702.6, R703.5, Table R905.7.4, Table R905.8.5
DASMADoor and Access Systems Manufacturers
Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
Standard
reference
number
TitleReferenced
in code
section number
108—05Standard Method for Testing Garage Doors: Determination of Structural
Performance Under Uniform Static Air Pressure Difference
R612.4
115—05Standard Method for Testing Garage Doors: Determination of Structural Performance
Under Missile Impact and Cyclic Wind Pressure
R301.2.1.2
DOCUnited States Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230
Standard
reference
number
TitleReferenced
in code
section number
PS 1—09Structural PlywoodR404.2.1, Table R404.2.3, R503.2.1,
R602.3, R604.1, R613.3.2, R803.2.1
PS 2—10Performance Standard for Wood-based Structural-use PanelsR404.2.1, Table R404.2.3,
R503.2.1, R602.3, R604.1,
R613.3.2, Table 613.3.2, R803.2.1
PS 20—05American Softwood Lumber StandardR404.2.1, R502.1, R602.1, R802.1
DOTnDepartment of Transportation
1200 New Jersey Avenue SE
East Building, 2nd floor
Washington, DC 20590
Standard
reference
number
TitleReferenced
in code
section number
14 CFR, Part 150 (2005)Airport Noise Compatibility Planning, Federal Aviation AdministrationR324.1
49 CFR, Parts 192.281(e)
& 192.283 (b) (2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety StandardsG2414.6.1
FEMAFederal Emergency Management Agency
500 C Street, SW
Washington, DC 20472
Standard
reference
number
TitleReferenced
in code
section number
FA/TB-2—08Flood-damage Resistant Materials RequirementsR322.1.8
FEMA-TB-11—01Crawlspace Construction for Buildings Located in Special Flood Hazard AreaR408.7
Florida CodesFlorida Building Commission
Building Codes and Standards
Department of Business and Professional Regulation
1940 N. Monroe Street, Suite 90A
Tallahassee, FL 32399-0772
Standard
reference
number
TitleReferenced
in code
section number
FBC-A—Fifth Edition (2014)Florida Building Code, AccessibilityR320.1
FBC-B—Fifth Edition (2014)Florida Building Code, BuildingR101.2.1, R301.2.1.1, R301.2.1.1.3, R301.2.1.6,
R301.2.5, R301.2.2.1.1, R301.2.2.1.2, R301.2.2.4, R301.3,
R308.5, R322.1.11, R403.1.1, R403.1.8, R403.1.2, R404.5.1,
Table R606.12.1, R606.13.8, R612.3, R615.1, R802.1.3.4,
R905.3.1, R905.10.3, R907.7, Table R907.7.1.2, R907.8, M1904.1,
G2402.3, R4401.1, R4402.1, R4403.1, R4404.1, R4405.1,
R4406.1, R4407.1, R4408.1, R4409.1, R4410.1, R4411.1,
R4412.1, 4501.1.2
FBC-EC—Fifth edition (2014)Florida Building Code, Energy ConservationR302.13, R408.3, R806.5, N1101
FBC-EB—Fifth edition (2014)Florida Building Code, Existing BuildingR101.2
FFPC—Fifth edition (2014)Florida Fire Prevention CodeM1904.1, M2201.7, G2402.3, G2412.2, R4501.1.2
FBC-FG—Fifth edition (2014)Florida Building Code, Fuel GasM1301.1, M1904.1, G2401.1, G2423.1,
R4501.1.2, R4501.15
FBC-M—Fifth edition (2014)Florida Building Code, MechanicalM1301.1, G2402.3, R4501.1.2
FBC-P—Fifth edition (2014)Florida Building Code, PlumbingTable R301.2(1), R903.4.1, G2402.3, P2601.1, P2902.5.5,
R4501.1.2, R4501.3, R4501.8.1, R4501.13.2
64ERule 64E, Florida Administrative Code (Sewage Disposal)R306.3, R322.1.7
FSFlorida StatutesR202, R318.1.7, R502.1.10.1, R802.1.7.2
FBC-TPHVHZ—
Fifth edition (2014
Florida Building Code, Test Protocols for High-Velocity Hurricane Zones
RAS 118R905.3, R905.3.2, R905.3.3, R905.3.3.1, R905.3.6, R905.3.8
RAS 119R905.3, R905.3.2, R905.3.3, R905.3.3.1, R905.3.6, R905.3.8
RAS120R905.3, R905.3.2, R905.3.3, R905.3.3.1, R905.3.6, R905.3.8
TAS 107R905.2.6.1, R905.16.3
TAS 114R904.4.2, R904.4.3
TAS 201R301.2.1.2, R612.3.1
TAS 202R301.2.1.2, R612.3, R612.4
TAS 203R301.2.1.2, R612.3.1
FMFactory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P. O. Box 7500
Johnson, RI 02919
Standard
reference
number
TitleReferenced
in code
section number
4450—(1989)Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992R906.1
4880—(2005)American National Standard for Evaluating Insulated Wall or Wall and Roof/Ceiling Assemblies,
Plastic Interior Finish Materials, Plastic Exterior Building Panels, Wall/Ceiling Coating Systems,
Interior or Exterior Finish Systems
R316.4, R316.6
FRSAFlorida Roofing, Sheet Metal and Air Conditioning Contractors Association
4111 Metric Drive
Winter Park, Florida 32792
Standard
reference
number
TitleReferenced
in code
section number
FRSA/TRI Florida High Wind Concrete and Clay Roof
Tile Installation Manual, Fifth Edition, Revised April 2012
R905.3, R905.3.2, R905.3.3,
R905.3.3.1, R905.3.6, R905.3.7, R905.3.7.1, R905.3.8
GAGypsum Association
810 First Street, Northeast, Suite 510
Washington, DC 20002-4268
Standard
reference
number
TitleReferenced
in code
section number
GA-253—07Application of Gypsum SheathingTable R602.3(1)
HPVAHardwood Plywood & Veneer Association
1825 Michael Faraday Drive
Reston, Virginia 20190-5350
Standard
reference
number
TitleReferenced
in code
section number
ANSI/HP-1—2009Standard for Hardwood and Decorative PlywoodR702.5
HVIHome Ventilating Institute
1000 N. Rand Road, Ste 214
Wauconda, IL 60084
Standard
reference
number
TitleReferenced
in code
section number
HVI 916—09Airflow Test ProcedureTable M1507.3
ICCInternational Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
Standard
reference
number
TitleReferenced
in code
section number
IBHS-2005Guidelines for Hurricane Resistant Residential Construction (with Errata)Figure R614.3(1), Figure R614.3(2)
ICC/ANSI A117.1—09Accessible and Usable Buildings and FacilitiesR321.3
ICC 400—12Standard on the Design and Construction of Log StructuresR301.1.1
ICC 500—08ICC/NSSA Standard on the Design and Construction of Storm SheltersR323.1
ICC 600—08Standard for Residential Construction in High-wind RegionsR301.2.1.1
SSTD 12—99Standard for Determining the Wind Resistance from Wind-Bourne DebrisR301.2.1.2
ISOInternational Organization for Standardization
1, ch. de la Voie - Creuse
Case postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
TitleReferenced
in code
section number
15874—2002Polypropylene Plastic Piping Systems for Hot and Cold Water InstallationsTable M2101.1
MAFMasonry Association of Florida
398 Camino Gardens Blvd, Suite 108
Boca Raton, FL 33432
Standard
reference
number
TitleReferenced
in code
section number
MAF—97Guide to Concrete Masonry Residential Construction in High Wind AreasR301.2.1.1
MSSManufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, Northeast
Vienna, VA 22180
Standard
reference
number
TitleReferenced
in code
section number
SP-58—93Pipe Hangers and Supports—Materials, Design and ManufactureG2418.2
NAIMANorth American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
reference
number
TitleReferenced
in code
section number
AH 116—09Fibrous Glass Duct Construction Standards, Fifth EditionM1601.1.1
NCMANational Concrete Masonry Association
13750 Sunrise Valley Drive
Herndon, VA 20171-4662
Standard
reference
number
TitleReferenced
in code
section number
TR 68-A—75Design and Construction of Plain and Reinforced Concrete Masonry
and Basement and Foundation Walls
R404.1.1
NFPANational Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Standard
reference
number
TitleReferenced
in code
section number
13—10Installation of Sprinkler SystemsR302.3
13D—10Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings
and Manufactured Homes
R313.2.1, P2904.1, P2904.2, P2904.6.1
31—11Installation of Oil-burning EquipmentM1801.3.1, M1805.3
58—11Liquefied Petroleum Gas CodeG2412.2, G2414.6.2
70—11National Electrical CodeE3401.1, E3401.2, E4301.1, Table E4303.2, E4304.3, E4304.4
72—10National Fire Alarm CodeR314.1, R314.2
82—09Standard on Incinerators and Waste Linen Handling Systems and EquipmentG2427.2.3
85—11Boiler and Construction Systems Hazards CodeG2452.1
211—10Chimneys, Fireplaces, Vents and Solid Fuel Burning AppliancesR1002.5, G2427.5.5.1
259—08Test Method for Potential Heat of Building MaterialsR316.5.7, R316.5.8
275—09Standard Method of Fire Tests for the Evaluation of
Thermal Barriers Used Over Foam Plastic Insulation
R316.4
286—11Standard Methods of Fire Tests for Evaluating Contribution of Wall
and Ceiling Interior Finish to Room Fire Growth
R302.9.4, R316.4,
R316.5.8, R316.6
501—10Standard on Manufactured HousingR202, AE201
720—09Standard for the Installation of Carbon Monoxide (CO) Detectors and Warning EquipmentR315.2
853—10Standard for the Installation of Stationary Fuel Cell Power SystemsM1903.1
NSFNSF International
789 N. Dixboro
Ann Arbor, MI 48105
Standard
reference
number
TitleReferenced
in code
section number
14—2008ePlastics Piping System Components and Related MaterialsM1301.4, P2608.3, P2908.3
42—2007aeDrinking Water Treatment Units—Anesthetic EffectsP2908.1, P2908.3
44—2007Residential Cation Exchange Water SoftenersP2908.1, P2908.3
53—2007aDrinking Water Treatment Units—Health EffectsP2908.1, P2908.3
58—2007Reverse Osmosis Drinking Water Treatment SystemsP2908.2, P2908.3
61—2008Drinking Water System Components—Health EffectsP2608.5, P2722.1, P2903.9.4,
P2905.4, P2905.5, P2905.6, P2907.3
372—2010Drinking Water System Components—Lead ContentP2905.2.1
PCAPortland Cement Association
5420 Old Orchard Road
Skokie, IL 60077
Standard
reference
number
TitleReferenced
in code
section number
100—07Prescriptive Design of Exterior Concrete Walls for One- and
Two-family Dwellings (Pub. No. EB241)
R301.2.2.2.4, R301.2.2.3.4, R404.1.2,
R404.1.2.2.1, R404.1.2.2.2, R404.1.2.4, R404.1.4.2,
R611.1, R611.2, R611.9.2, R611.9.3
SBCAStructural Building Components Association
6300 Enterprise Lane
Madison, WI 53719
Standard
reference
number
TitleReferenced
in code
section number
BCSI—2008Building Component Safety Information Guide to Good Practice for Handling,
Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses
502.11.2, 802.10.3
CFS-BCSI—2008Guide to Good Practice for Handling, Installing & Bracing of Cold-formed Steel Trusses505.1.3, 804.3.7
SDISteel Door Institute
c/o Wherry Associates
30200 Detroit Road
Cleveland, Ohio 44145-1967
Standard
reference
number
TitleReferenced
in code
section number
ANSI A250—03Testing and Rating of Severe Reistant Components for Swinging Door AssembliesR612.9.1
SMACNASheet Metal & Air Conditioning Contractors National Assoc. Inc.
4021 Lafayette Center Road
Chantilly, VA 22021
Standard
reference
number
TitleReferenced
in code
section number
SMACNA—10Fibrous Glass Duct Construction Standards (2003)M1601.1.1, M1601.4.1
HVAC Duct Construction Standards—Metal and Flexible (2005)M1601.4.1
TMSThe Masonry Society
3970 Broadway, Suite 201-D
Boulder, CO 80304
Standard
reference
number
TitleReferenced
in code
section number
302—07Standard Method for Determining the Sound Transmission
Class Rating for Masonry Walls
AK102.1.1
402—11Building Code Requirements for Masonry StructuresR404.1.1, R606.1, R606.1.1,
R606.12.1, R606.12.2.3.1,
R606.12.3.2, Table R703.4
403—10Direct Design Handbook for Masonry StructuresR606.1, R606.1.1, R606.12.1,
R606.12.3.1
602—11Specification for Masonry StructuresR404.1.1, R606.12.3.1, Table R703.4
TPITruss Plate Institute
583 D'Onofrio Drive, Suite 200
Madison, WI 53719
Standard
reference
number
TitleReferenced
in code
section number
TPI 1—2007National Design Standard for Metal-plate-connected
Wood Truss Construction
R502.11.1, R802.10.2
ULUnderwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
TitleReferenced
in code
section number
17—2008Vent or Chimney Connector Dampers for Oil-fired AppliancesM1802.2.2
55A—04Materials for Built-up Roof CoveringsR905.9.2
58—96 Steel Underground Tanks for Flammable and Combustible Liquids—
with Revisions through July 1998
M2201.1
80—07Steel Tanks for Oil-burner FuelM2201.1
103—01Factory-built Chimneys for Residential Type and Building Heating
Appliances—with Revisions through March 2010
R202, R1005.3, G2430.1
127—08Factory-built Fireplaces—with Revisions through January 2010R1001.11, R1004.1,
R1004.4, R1005.4, G2445.7,
174—04 Household Electric Storage Tank Water Heaters—
with Revisions through November 2005
M2005.1
180—03Liquid-level Indicating Gauges for Oil Burner Fuels—with Revision through March 2007M2201.5
181—05Factory-made Air Ducts and Air Connectors—with Revisions through May 2003M1601.2, M1601.4.1
181A—05Closure Systems for Use with Rigid Air Ducts and Air Connectors—
with Revisions through December 1998
M1601.2, M1601.4.1
181B—05Closure Systems for Use with Flexible Air Ducts and Air Connectors—
with Revisions through August 2003
M1601.2, M1601.4.1
217—06Single- and Multiple-station Smoke Alarms—with Revisions through April 2010R314.1
263—03 Standards for Fire Test of Building Construction and Materials—
with Revisions through October 2007
Table R302.1(2), R302.2, R302.3, R302.4.1, R316.4
325—02Door, Drapery, Gate, Louver and Window Operations and Systems—
with Revisions through February 2010
R309.4
343—97Pumps for Oil-burning Appliances—with Revisions through May 2002M2204.1
378—06Draft EquipmentM1804.2.6
441—10Gas VentsG2426.1
508—99Industrial Control Equipment—with Revisions through April 2010M1411.3.1
536—97Flexible Metallic Hose—with Revisions through June 2003M2202.3
641—95Type L, Low-temperature Venting Systems—
with Revisions through July 2009
R202, R1003.11.5, M1804.2.4, G2426.1
651—05Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings—
with Revisions through March 2010
G2414.6.3
723—03Standard for Test for Surface Burning Characteristics of
Building Materials—with Revisions through May 2005
R302.9.3, R302.9.4, R302.10.1, R302.10.2,
R316.3, R316.5.9, R316.5.10, R316.6, R802.1.3, M1601.3
726—95Oil-fired Boiler Assemblies—with Revisions through April 2010M2001.1.1, M2006.1
727—06Oil-fired Central Furnaces—with Revisions through April 2010M1402.1
729—03Oil-fired Floor Furnaces—with Revisions through April 2010M1408.1
730—03Oil-fired Wall Furnaces—with Revisions through April 2010M1409.1
732—95Oil-fired Storage Tank Water Heaters—with Revisions through April 2010M2005.1
737—07Fireplaces StovesM1414.1, M1901.2
790—04Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through October 2008R902.1
795—06Commercial-industrial Gas Heating Equipment—
with Revisions through April 2010
G2442.1, G2452.1
834—04Heating, Water Supply and Power Boilers—Electric—with Revisions
through December 2009
M2001.1.1
842—07Valves for Flammable FluidsM2204.2
858—05Household Electric Ranges—with Revisions through November 2007M1901.2
875—09Electric Dry-bath HeatersM1902.2
896—93Oil-burning Stoves—with Revisions through May 2010M1410.1
923—08Microwave Cooking Appliances—with Revisions through June 2010M1504.1
959—01Medium Heat Appliance Factory-built Chimneys—
with Revisions through June 2010
R1005.6
1026—07Electric Household Cooking and Food Serving AppliancesM1901.2
1040—96Fire Test of Insulated Wall Construction—with Revisions through June 2001R316.4, R316.6
1042—94Electric Baseboard Heating Equipment—with Revisions through February 2008M1405.1
1256—02Fire Test of Roof Deck ConstructionR906.1
1261—01Electric Water Heaters for Pools and Tubs—with Revisions through June 2004M2006.1
1453—04Electronic Booster and Commercial Storage Tank Water Heaters—
with Revisions through December 2009
M2005.1
1479—03Fire Tests of Through-Penetration Firestops—with Revisions through March 2010R302.4.1.2
1482—10Solid-Fuel-type Room HeatersR1002.2, R1002.5, M1410.1
1618—09Wall Protectors, Floor Protectors, and Hearth ExtensionsM1004.2
1673—96Electric Space Heating Cables—with Revisions through July 2003M1406.1
1693—02Electric Radiant Heating Panels and Heating Panel SetsM1406.1
1703—02Flat-plate Photovoltaic Modules and Panels—with Revisions through April 2008R905.16.1, R905.17.4, M2302.3
1741—99Inverters, Converters, Controllers and Interconnection System Equipment with
Distributed Energy Resources—with Revisions through November 2005
M2302.4
1715—97Fire Test of Interior Finish Material—with Revisions through March 2004R316.6
1738—06Venting Systems for Gas-burning Appliances, Categories II, III and IVG2426.1
1741—99Inverters, Converters, Controllers and Interconnection System Equipment
for use with Distributed Energy Resources—with Revisions through November 2005
M2302.4
1777—04Chimney Liners with Revisions through June 2009R1003.11.1, R1003.18,
G2425.12, G2425.15.4, M1801.3.4,
1995—05Heating and Cooling Equipment—with Revisions through July 2009M1402.1, M1403.1,
M1407.1, M1412.1, M1413.1
1996—04Electric Duct Heaters—with Revisions through December 2006M1402.1
2017—08Standard for General-purpose Signaling Devices and Systems—
with Revisions through October 2009
AG105.2
2523—03Outline of Investigation for Sealed Fuel-fired Water Heaters and BoilersM2001.1.1
2034—08Standard for Single- and Multiple-station Carbon Monoxide AlarmsR202, R315.4
2075—04Standard for Gas and Vapor Detectors and Sensors—with Revisions
through September 28, 2007
R202, R315.2
2158A—06Outline of Investigation for Clothes Dryer Transition DuctM1502.4.3
ULCUnderwriters’ Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada M1R 3B4
Standard
reference
number
TitleReferenced
in code
section number
CAN/ULC S 102—1988Standard Methods for Test for Surface Burning Characteristics
of Building Materials and Assemblies—with 2000 revisions
R302.10.2
US-FTCUnited States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
Standard
reference
number
TitleReferenced
in code
section number
CFR Title 16
(May 31, 2005)
R-value Rule303.1.4
WDMAWindow & Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
Standar
reference
number
TitleReferenced
in code
section number
AAMA/WDMA/CSA
101/I.S2/A440—11
Specifications for Windows, Doors and SkylightsR308.6.9, R612.3
Resources