This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ANSI American National Standards Institute
25 West 43rd Street
Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
ANSI A13.1—2007 Scheme for the Identification of Piping Systems 704.1.2.2
ANSI CSA-America FC 1—03Stationery Fuel Cell Power Systems 633.1
LC 1/CSA 6.26—05Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST)403.5.4
ANSI LC-4—07Press-connect Copper and Copper Alloy Fittings for Use In Fuel Gas Distribution Systems403.10.2
Z21.1—05Household Cooking Gas Appliances623.1
Z21.5.1/CSA 7.1—06Gas Clothes Dryers—Volume I—Type 1 Clothes Dryers613.1
Z21.5.2/CSA 7.2—05Gas Clothes Dryers—Volume II—Type 2 Clothes Dryers613.1,614.3
Z21.8—94 (R2002)Installation of Domestic Gas Conversion Burners619.1
Z21.10.1/CSA 4.1—09Gas Water Heaters—Volume I—Storage, Water Heaters with Input Ratings of 75,000 Btu per Hour or Less624.1
Z21.10.3/CSA 4.3—04Gas Water Heaters—Volume III—Storage, Water Heaters with Input Ratings Above 75,000 Btu per hour, Circulating and Instantaneous624.1
Z21.11.2—07Gas-fired Room Heaters-Volume II-Unvented Room Heaters621.1
Z21.13/CSA 4.9—10Gas-fired Low-pressure Steam and Hot Water Boilers631.1
Z21.15/CGA 9.1—09Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves409.1.1
Z21.19/CSA 1.4—02(R2007)Refrigerators Using Gas (R1999) Fuel625.1
Z21.24/CGA 6.10—06Connectors for Gas Appliances411.1
Z21.40.1/CGA 2.91—96 (R2002)Gas-Fired Heat Activated Air Conditioning and Heat Pump Appliances627.1
Z21.40.2/CGA 2.92—96 (R2002)Gas-Fired Work Activated Air Conditioning and Heat Pump Appliances (Internal Combustion)627.1
Z21.42—93 (R2002)Gas-Fired Illuminating Appliances628.1
Z21.47/CSA 2.3—06Gas-Fired Central Furnaces618.1
Z21.50/CSA 2.22—07Vented Gas Fireplaces604.1
Z21.56/CSA 4.7—06Gas-Fired Pool Heaters617.1
Z21.58/CSA 1.6—07Outdoor Cooking Gas Appliances623.1
Z21.60/CSA 2.26—03Decorative Gas Appliances for Installation in Solid-fuel Burning Fireplaces602.1
Z21.61—83 (R2004)Gas-fired Toilets626.1
Z21.69/CSA 6.16—09Connectors for Movable Gas Appliances411.1.1
Z21.75/CSA 6.27—07Connectors for Outdoor Gas Appliances and Manufactured Homes411.1, 411.2
Z21.80—03(R2008)Line Pressure Regulators410.1
Z21.84—02Manually-lighted, Natural Gas Decorative Gas Appliances for Installation in
Solid Fuel Burning Fireplaces—with Addenda Z21.84a-2003
602.1, 602.2
Z21.86—08Vented Gas-fired Space Heating Appliances608.1, 609.1, 622.1
Z21.88/CSA 2.33—09Vented Gas Fireplace Heaters605.1
Z21.91—07Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters 621.7.1
Z21.97—09Outdoor Decorative Appliances636
Z83.4/CSA 3.7—03Nonrecirculating Direct-gas-fired Industrial Air Heaters611.1
Z83.6—90 (R1998)Gas-fired Infrared Heaters630.1
Z83.8/CSA 2.6—09Gas Unit Heater, Gas Packaged Heater, Gas Utility Heaters and Gas-fired Duct Furnaces620.1
Z83.11/CSA 1.8—06Gas Food Service Equipment623.1
Z83.18—04Recirculating Direct Gas-fired Industrial Air Heaters612.1
Z83.19—01(R2005)Gas-fired High-intensity Infrared Heaters630.1
Z83.20—08Gas-fired Low-intensity Infrared Heaters630.1