ADOPTS WITH AMENDMENTS:

International Existing Building Code 2018 (IEBC 2018)

Heads up: There are no amended sections in this chapter.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4 of the Florida Building Code, Building.

ACI

American Concrete Institute
38800 Country Club Drive
Farmington Hills MI 48331

ACI 562—19

Code Requirements for Assessment, Repair, and Rehabilitation of Existing Concrete Structures

301.3.4

ASCE/SEI

American Society of Civil Engineers Structural
Engineering Institute
1801 Alexander Bell Drive
Reston VA 20191-4400

7—16

Minimum Design Loads for Buildings and Other Structures with Supplement No. 1

503.4, 503.9, Table 706.8.1, 807.5, 807.6

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329

62.1—2016

Ventilation for Acceptable Indoor Air Quality

809.2

ASME

American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016

ASME A17.1/CSA B44—2016

Safety Code for Elevators and Escalators

902.1.2

A17.3—2015

Safety Code for Existing Elevators and Escalators

902.1.2

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959

E136—2016

Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C

202

F1667—2016

Specification for Driven Fasteners: Nails, Spikes and Staples

706.7.1.2

F2006—17

Standard Safety Specification for Window Fall Prevention Devices for Non Emergency Escape (Egress) and Rescue (Ingress) Windows

505.2, 702.4

F2090—17

Standard Specification for Window Fall Prevention Devices with Emergency (Egress) Release Mechanisms

505.2, 505.3, 702.4, 702.5

Florida Codes

Florida Building Commission
c/o Florida Department of Business and Professional Regulation Building Codes and Standards
Building Codes and Standards
2601 Blair Stone Road
Tallahassee Florida 32399

FBC-A—7th Edition (2020)

Florida Building Code, Accessibility

705.1, 806.1, 906.1, 1006.1, 1012.8, 1105.1, 1201.4, 1508

FBC-EC—7th Edition (2020)

Florida Building Code, Energy Conservation

302, 702.6, 811.1, 908.1, 1013, 1106.1

FBC-M—7th Edition (2020)

Florida Building Code, Mechanical

302, 702.6, 809.1, 902.1.1, 1009.1, 1401.6.7.1, 1401.6.8, 1401.6.8.1

FBC-P—7th Edition (2020)

Florida Building Code, Plumbing

302, 609.1, 702.6, 810.1, 909, 1010.1, 1010.2, 1010.3, 1010.5, 1501.7

FBC-FG—7th Edition (2020)

Florida Building Code, Fuel Gas

302.2

FBC-TP HVHZ—7th Edition (2020)

Florida Building Code, Test Protocols for High-Velocity Hurricane Zones RAS 120

1207.2

ICC

International Code Council, Inc.
500 New Jersey Ave. NW, 6th Floor
Washington DC 20001

ICC 300—17

ICC Standard on Bleachers, Folding and Telescopic Seating, and Grandstands

501.1

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471

NFPA 13R—16

Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies up to and Including Four Stories in Height

804.2.4

NFPA 70—17

National Electrical Code

301.2, 302.2, 302.6.2, 407.1.1, 407.1.2, 407.1.3, 407.1.4, 407.1.5, 808.1, 808.3.4, 808.3.7, 1008.1, 1008.2, 1008.3, 1008.4

NFPA 72—16

National Fire Alarm and Signaling Code

804.2.4, 804.4

NFPA 99—18

Health Care Facilities Code

407.1.4

NFPA 101—18

Life Safety Code

805.2

NFPA 914—01

Code for Fire Protection of Historic Structures

1205.2, 1205.3, 1206.1