This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4 of the Florida Building Code, Building.

ASCE/SEI

American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston VA 20191-4400
Standard
reference
number
TitleReferenced
in code
section number

7—10

Minimum Design Loads for Buildings and Other Structures with Supplement No. 1

301.1.4.1403.4403.9807.5

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329
Standard
reference
number
TitleReferenced
in code
section number

62.1—2013

Ventilation for Acceptable Indoor Air Quality

809.2

ASME

American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016
Standard
reference
number
TitleReferenced
in code
section number

ASME A17.1/CSA B44—2013

Safety Code for Elevators and Escalators

410.8.2705.1.2902.1.2

A17.3—2008

Safety Code for Existing Elevators and Escalators

902.1.2

A18.1—2008

Safety Standard for Platform Lifts and Stairway Chair Lifts

410.8.3705.1.3

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959
Standard
reference
number
TitleReferenced
in code
section number

C94/C94M—13

Specification for Ready-mixed Concrete

E84—13A

Test Method for Surface Burning Characteristics of Building Materials

E108—11

Standard Test Methods for Fire Tests of Roof Coverings

E136—2012

Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C

202

F1667—2016

Specification for Driven Fasteners: Nails, Spikes and Staples

706.7.1.2

F2006—10

Standard Safety Specification for Window Fall Prevention Devices for Non Emergency Escape (Egress) and Rescue (Ingress) Windows

406.2702.4

F2090—10

Standard Specification for Window Fall Prevention Devices with Emergency (Egress) Release Mechanisms

406.2702.4

Florida Codes

Florida Building Commission
c/o Florida Department of Business and Professional Regulation Building Codes and Standards
Building Codes and Standards
2601 Blair Stone Road
Tallahassee Florida 32399
Standard
reference
number
TitleReferenced
in code
section number

FBC-B—6th Edition (2017)

Florida Building Code, Building

101.1101.2101.4.1101.8202301302.5401.2.3402.1402.2402.3402.4403.1403.2403.3403.4403.8403.9403.11404404.2.1404.5406407601.3602606606.2.4701.2701.3702706.1706.3706.5706.6706.7Table 706.7.1.2706.8Table 706.8.1707.1707.2707.3707.58018028038048058079049059071001100210041007.11007.21007.3101110121102.11102.31103.512011207.21301.213021302.2.1.11302.31302.614011401.3.31501150617011703

FBC-A—6th Edition (2017)

Florida Building Code, Accessibility

410.1705.1806.1906.11006.11012.81105.11201.41508

FBC-EC—6th Edition (2017)

Florida Building Code, Energy Conservation

302702.6811.1908.110131106.1

FFPC—6th Edition (2017)

Florida Fire Prevention Code

101.4.2202301.1.1302402.5403.10803.2.1803.2.3804.4.1.1804.4.1.2804.4.1.3804.4.1.4804.4.1.5804.4.1.6804.4.1.7804.4.31012.5.1.111041301.21401.3.21401.6.8.11401.6.141401.6.14.11501.51504.11504.2

FBC-M—6th Edition (2017)

Florida Building Code, Mechanical

302702.6809.1902.1.11009.11401.6.7.11401.6.81401.6.8.1

FBC-P—6th Edition (2017)

Florida Building Code, Plumbing

302609.1702.6810.19091010.11010.21010.31010.51501.7

FBC-R—6th Edition (2017)

Code Florida Building Code, Residential

101.4.1302402.2403.2404.5601.3602.3606.2.4701.3702706.1Table 706.7.1.2Table 706.8.1807.4808.3907.41103.21103.31103.41103.51104.11201.31302.11302.21302.2.11302.41302.51302.61401.2.21401.2.31401.3.3

FBC-FG—6th Edition (2017)

Florida Building Code, Fuel Gas

302.2

FBC-TP HVHZ—6th Edition (2017)

Florida Building Code, Test Protocols for High-Velocity Hurricane Zones RAS 120

1207.2

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471
Standard
reference
number
TitleReferenced
in code
section number

NFPA 13R—13

Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height

804.2.5

NFPA 70—14

National Electrical Code

302.6.2607.1.1607.1.2607.1.3607.1.4607.1.5808.1808.3.4808.3.71008.11008.21008.31008.4

NFPA 72—13

National Fire Alarm and Signaling Code

804.2.5804.4

NFPA 99—15

Health Care Facilities Code

607.1.4

NFPA 101—15

Life Safety Code

805.2

NFPA 914—01

Code for Fire Protection of Historic Structures

1205.21205.31206.1

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062
Standard
reference
number
TitleReferenced
in code
section number

723—08

Standard for Test for Surface Burning Characteristics of Building Materials with Revisions through September 2010

790—04

Standard Test Methods for Fire Tests of Roof Coverings with Revisions through October 2008