ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD

ESTIMATED ENERGY PERFORMANCE INDEX* = ____

The lower the Energy Performance Index, the more efficient the home.

FORM R400D-2014

DESUPERHEATER, HEAT RECOVERY UNIT (HRU) WATER HEATER
EFFICIENCY CERTIFICATION
TESTS CONDUCTED IN ACCORDANCE WITH
AHRI STANDARD 470

TABLE R402A

BUILDING COMPONENTPRESCRIPTIVE REQUIREMENTS1INSTALLED VALUES
Climate Zone 1Climate Zone 2
Windows:U-Factor = 0.652U-Factor = 0.402U-Factor =
SHGC = 0.25SHGC = 0.25SHGC =
SkylightsU-factor = 0.75U-factor = 0.65U-factor =
SHGC = 0.30SHGC = 0.30SHGC =
Doors: Exterior doorU-factor = 0.653U-factor = 0.403U-factor=
Floors:
Slab-on-GradeNRNR
Over unconditioned spaces4R-13R-13R-Value =
Walls4 : Ext. and Adj.
FrameR-13R-13R-Value =
Mass
Insulation on wall interior:R-4R-6R-Value =
Insulation on wall exteriorR-3R-4R-Value =
Ceilings5:R=30R=38R-Value =
Air infiltration:Blower door test is required on the building envelope to verify leakage ≤ 5 ACH;Total leakage = ACH
test report provided to code official.Test report Attached?
Yes No
Air distribution system5 :
Air handling unitNot allowed in atticLocation:
Duct R-valueR-value ≥ R-8 (supply in attics) or ≥ R-6 (all other duct locations)-R-Value =
Air leakage5:
Duct testPostconstruction test:Total leakage ≤ 4 cfm/100 s.f.Total leakage =_______ cfm/100s.f.
Rough-in testTotal leakage ≤ 3 cfm/100 s.f.Test report Attached? Yes No
Ducts in conditioned spaceTest not required if all ducts and AHU are in conditioned spaceLocation:
Air conditioning system:Minimum federal standard required by NAECA6.
Central system ≤ 65,000 Btu/hSEER 13.0SEER=
Room unit or PTACEER [from Table C403.2.3(3)]EER =
Other:See Tables C403.2.3(1)-(11)
Heating system:Minimum federal standard required by NAECA6
Heat pump ≤ 65,000 Btu/hHSPF 7.7 (before 1/1/15); HSPF 8.2 (as of 1/1/15)HSPF =
Gas furnace, non-weatherizedAFUE 80%AFUE =
Oil furnace, non-weatherizedAFUE 83%AFUE =
Other:
Water heating system (storage type):Minimum federal standard required by NAECA6
Electric740 gal: EF = 0.92Gallons =
50 gal: EF = 0.90EF =
Gas fired840 gal: EF = 0.59Gallons =
50 gal: EF = 0.58EF =
Other (describe):
NR = No requirement.
(1) Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using this method.
(2) For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code, Residential or Section 1609.1.2 of the Florida Building Code, Building the maximum U-factor shall be 0.75 in Climate Zone 1 and 0.65 in Climate Zone 2. An area-weighted average of U-factor and SHGC shall be accepted to meet the requirements, or up to 15 square feet of glazed fenestration area are exempted from the U-factor and SHGC requirement based on Sections R402.3.1, R402.3.2 and R402.3.3.
(3) One side-hinged opaque door assembly up to 24 square feet is exempted from this U-factor requirement.
(4) R-values are for insulation material only as applied in accordance with manufacturers' installation instructions. For mass walls, the "interior of wall" requirement must be met except if at least 50 percent of the insulation required for the "exterior of wall" is installed exterior of, or integral to, the wall.
(5) Ducts & AHU installed "substantially leak free" per Section R403.2.2. Test required by an energy rater certified in accordance with Section 553.99, Florida Statutes, or as authorized by Florida Statutes. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope.
(6) Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1987 for typical residential equipment and are subject to NAECA rules and regulations. For other types of equipment, see Tables C403.2.3(1-11) of the Commercial Provisions of the Florida Building Code, Energy Conservation.
(7) For other electric storage volumes, min. EF = 0.97 - (0.00132 * volume).
(8) For other natural gas storage volumes, min. EF = 0.67 - (0.0019 * volume).
TABLE R402B MANDATORY REQUIREMENTS
ComponentSectionSummary of Requirement(s)Check
Air leakageR402.4To be caulked, gasketed, weatherstripped or otherwise sealed per TableR402.4.1.1. Recessed lighting: IC-rated as having ≤ 2.0 cfm tested to ASTM E 283.
Windows and doors: 0.3 cfm/sq.ft (swinging doors: 0.5 cfm/sf) when tested to NFRC 400 or AAMA/WDMA/CSA 101/I.S. 2/A440.
Fireplaces: Tight-fitting flue dampers & outdoor combustion air.
Programmable
thermostat
R403.1.2Where forced-air furnace is primary system, a programmable thermostat is required.
Air distribution systemR403.2.2Ducts shall be tested to Section 803 of the RESNET standards by an energy rater certified in accordance with Section 553.99,Florida Statutes, or as authorized by Florida Statutes. Air handling units are not allowed in attics.
R403.2.4
Water heatersR403.4Comply with efficiencies in Table C404.2. Hot water pipes insulated to ≥ R-3 to kitchen outlets, other cases.
Circulating systems to have an automatic or accessible manual OFF switch. Heat trap required for vertical pipe risers.
Swimming pools & spasR403.9Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency is 82%. Heat pump pool heaters minimum COP is 4.0.
Cooling/heating
equipment
R403.6Sizing calculation performed & attached. Special occasion cooling or heating capacity requires separate system or variable capacity system.
Lighting equipmentR404.1At least 75% of permanently installed lighting fixtures shall be high-efficacy lamps.