CODES

ADOPTS WITH AMENDMENTS:

International Energy Conservation Code 2012 (IECC 2012)

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section C106.

AABCAssociated Air Balance Council,
1518 K Street, Suite 503,
Washington, DC 20005
Standard
reference
number
TitleReferenced
in code
section number
AABC—1989Associated Air Balance Council National Standard C408.2.2.1
AAMAAmerican Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg, IL 60173-4268
Standard
reference
number
TitleReferenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A C440—11
North American Fenestration Standard/
Specifications for Windows, Doors and Unit Skylights
Table C402.4.3
ACCAAir Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
TitleReferenced
in code
section number
ACCA Manual D—1995 Residential Duct SystemsC403.2.7.5
ACCA Manual N—2005Commercial Load Calculation C403.2.1
ANSI/ASHRAE/ ACCA 183—2007Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings C403.2.1
ADCAir Diffusion Council
1000 E. Woodfield Rd., Suite 102
Schaumburg, IL 60173-5921
Standard
reference
number
TitleReferenced
in code
section number
ADC 2003Flexible Duct Performance & Installation Standards, Fourth Edition Table C403.2.7.2
AHAMAssociation of Home Appliance Manufacturers
1111 19th Street, NW, Suite 402
Washington, DC 20036
Standard
reference
number
TitleReferenced
in code
section number
ANSI/
AHAM RAC-1—2008
Room Air Conditioners Table C403.2.3(3)
AHRIAir Conditioning, Heating, and Refrigeration Institute
4100 North Fairfax Drive
Suite 200
Arlington, VA 22203
Standard
reference
number
TitleReferenced
in code
section number
AHRI 1230—2010Performance Rating of Variable Refrigerant Flow (VRF)
Multi-Split Air-Conditioning and Heat Pump Equipment With Addendum 1
Table C403.2.3(11)
ISO/AHRI/ASHRAE
13256-1 (2005)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 1: Water-to-air and Brine-to-air Heat Pumps
Table C403.2.3(2)
ISO/AHRI/ASHRAE
13256-2 (1998)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 2: Water-to-water and Brine-to-water Heat Pumps
Table C403.2.3(2)
210/240—08Unitary Air Conditioning and Air-source Heat Pump EquipmentTable C403.2.3(1), Table C403.2.3(2)
310/380—04Standard for Packaged Terminal Air Conditioners and Heat PumpsTable C403.2.3(3)
340/360—2007Commercial and Industrial Unitary Air-conditioning and
Heat Pump Equipment
Table C403.2.3(1), Table C403.2.3(2)
365—09Commercial and Industrial Unitary Air-conditioning
Condensing Units
Table C403.2.3(1), Table C403.2.3(6)
390—03Performance Rating of Single Package Vertical Air Conditioners
and Heat Pumps
Table C403.2.3(3)
400—01Liquid to Liquid Heat Exchangers with Addendum 2Table C403.2.3(9)
440—08Room Fan CoilC403.2.8
460—05Performance Rating Remote Mechanical Draft Air-cooled
Refrigerant Condensers
Table C403.2.3(8)
550/590—03Water Chilling Packages Using the Vapor Compression Cycle—with AddendaC403.2.3.1,
Table C403.2.3(7), Table C406.2(6)
560—00Absorption Water Chilling and Water-heating PackagesTable C403.2.3(7), Table C406.2(6)
840—1998Unit Ventilators C403.2.8
1160—08Performance Rating of Heat Pump Pool Heaters Table C404.2
AMCAAir Movement and Control Association International30 West University Drive
Arlington Heights, IL 60004-1806
Standard
reference
number
Title Referenced
in code
section number
500D—10 Laboratory Methods for Testing Dampers for Rating C402.4.5.1, C402.4.5.2
ANSIAmerican National Standards Institute
25 West 43rd Street
Fourth Floor
New York, NY 10036
Standard
reference
number
TitleReferenced
in code
section number
A 112.18.1M—1999Finished and Rough Brass Plumbing Fixture Fittings C404.8.1
Z21.10.3/CSA 4.3—04Gas Water Heaters, Volume III—Storage Water Heaters with Input Ratings
Above 75,000 Btu per Hour, Circulating Tank and Instantaneous
Table C404.2
Z21.47/CSA 2.3—06Gas-fired Central FurnacesTable C403.2.3(4), Table C406.2.(4)
Z83.8/CSA 2.6—09Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters
and Gas-fired Duct Furnaces
Table C403.2.3(4), Table C406.2.(4)
ASHRAEAmerican Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329-2305
Standard
reference
number
TitleReferenced
in code
section number
ANSI/ASHRAE/ACCA
Standard 183—2007
Peak Cooling and Heating Load Calculations in Buildings,
Except Low-rise Residential Buildings
C403.2.1
ASHRAE—2008ASHRAE HVAC Systems and Equipment Handbook—2008 C403.2.1
ISO/AHRI/ASHRAE
13256-1 (2005)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 1: Water-to-air and Brine-to-air Heat Pumps
Table C403.2.3(2)
ANSI/ASHRAE
Std. 55—1992
Thermal Environmental Conditions for Human Occupancy C403.4.8
ISO/AHRI/ASHRAE
13256-2 (1998)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 2: Water-to-water and Brine-to-water Heat Pumps
Table C403.2.3(2)
ANSI/ASHRAE/90.1—2010
90.1—2010
Energy Standard for Buildings Except Low-rise Residential Buildings C304.1.1, C304.3.1.4, C304.3.2.1,
C304.3.2.2, C401.2, C401.2.1, C402.1.1,
Table C402.1.2, Table C402.2, C405.7.1, Table C407.6.1
119—88 (RA 2004)Air Leakage Performance for Detached Single-family Residential Buildings Table C405.5.2(1)
127—07Method of Testing for Rating Computer and Data Processing
Room Unitary Air Conditioners
Table C403.2.3(10)
140—2010Standard Method of Test for the Evaluation of Building Energy
Analysis Computer Programs
C407.6.1
146—2006Testing and Rating Pool Heaters Table C404.2
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2859
Standard
reference
number
TitleReferenced
in code
section number
C36/C36M—03Standard Specification for Gypsum Wallboard202
C 90—08Specification for Load-bearing Concrete Masonry UnitsC304.1.1, Table C402.2
C 177—04Test Method for Steady-State Heat Flux Measurements and Thermal Transmission
Properties by Means of the Guarded-Hot-Plate Apparatus
C304.2.1
C236—89 (1993el)Test Method for Steady State Thermal Performance of Building Assemblies
by Means of a Guarded Hot Box
C304.2.1
C 518—04Test Method for Steady-State Thermal Transmission Properties by Means
of the Heat Flow Meter Apparatus
C304.2.1
C1363—05Standard Test Method for Thermal Performance of Building Materials and
Envelope Assemblies by Means of a Hot Box Apparatus
C304.2.2
C 1371—04Standard Test Method for Determination of Emittance of Materials
Near Room Temperature Using Portable Emissometers
Table C402.2.1.1
C 1549—04Standard Test Method for Determination of Solar Reflectance Near
Ambient Temperature Using A Portable Solar Reflectometer
Table C402.2.1.1
D 1003—07e1Standard Test Method for Haze and Luminous Transmittance of
Transparent Plastics
C402.3.2.2
D2412—02(2008)Test Method for Determination of External Loading Characteristics of
Plastic Pipe by Parallel Pipe Loading
Table C403.2.7.2
E 84-09Test Method for Surface Burning Characteristics of Building MaterialsC403.2.7.3.7
E 283—04Test Method for Determining the Rate of Air Leakage Through Exterior
Windows, Curtain Walls and Doors Under Specified Pressure
Differences Across the Specimen
C402.4.1.2.2,
Table C402.4.3, C402.4.8
E 408—71(2002)Test Methods for Total Normal Emittance of Surfaces Using
Inspection-meter Techniques
Table C402.2.1.1
E 779—03Standard Test Method for Determining Air Leakage Rate by Fan PressurizationC402.4.1.2.3
E 903—96Standard Test Method Solar Absorptance, Reflectance and
Transmittance of Materials Using Integrating Spheres (Withdrawn 2005)
Table C402.2.1.1
E 1677—05Standard Specification for an Air-retarder (AR) Material or System for
Low-rise Framed Building Walls
C402.4.1.2.2
E 1918—97Standard Test Method for Measuring Solar Reflectance of
Horizontal or Low-sloped Surfaces in the Field
Table C402.2.1.1
E 1980—(2001)Standard Practice for Calculating Solar Reflectance Index of
Horizontal and Low-sloped Opaque Surfaces
Table C402.2.1.1
E 2178—03Standard Test Method for Air Permanence of Building MaterialsC402.4.1.2.1
E 2357—05Standard Test Method for Determining Air Leakage of Air Barriers AssembliesC402.4.1.2.2
CSACanadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
Table C402.4.3
CTICooling Technology Institute
2611 FM 1960 West, Suite A-101
Houston, TX 77068
Standard
reference
number
Title Referenced
in code
section number
ATC 105 (00) Acceptance Test Code for Water Cooling Tower Table C403.2.3(8)
STD 201—09Standard for Certification of Water Cooling Towers Thermal Performances Table C403.2.3(8)
DASMADoor and Access Systems Manufacturers Association
1300 Sumner Avenue
Cleveland, OH 44115-2851
Standard
reference
number
Title Referenced
in code
section number
105—92 (R2004) Test Method for Thermal Transmittance and Air Infiltration of Garage Doors Table C402.4.3
DOEU.S. Department of Energy
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
10 CFR, Part 430—1998 Energy Conservation Program for Consumer Products:
Test Procedures and Certification and Enforcement Requirement
for Plumbing Products; and Certification and Enforcement
Requirements for Residential Appliances; Final Rule
Table C403.2.3(4), Table C403.2.3(5),
Table C404.2, Table C406.2(4), Table C406.2(5)
10 CFR, Part 430, Subpart B,
Appendix N—1998
Uniform Test Method for Measuring the Energy Consumption of
Furnaces and Boilers
C202
10 CFR, Part 431—2004Energy Efficiency Program for Certain Commercial and Industrial
Equipment: Test Procedures and Efficiency Standards; Final Rules
Table C403.2.3(5), Table C406.2(5)
NAECA 87—(88)National Appliance Energy Conservation Act 1987
[(Public Law 100-12 (with Amendments of 1988-P.L. 100-357)]
Tables C403.2.3(1), (2), (4)
Florida CodesBuilding Codes and Standards Office
Florida Department of Business and Professional Regulation
1940 N Monroe Street, Suite 90A
Tallahassee, FL 32399-0772
Standard
reference
number
TitleReferenced
in code
section number
FBC-B—Fifth Edition (2014)Florida Building Code, BuildingC201.3, C202, C303.2, C402.4.4
FBC-M—Fifth Edition (2014)Florida Building Code, MechanicalC201.3, C403.2.5, C403.2.5.1, C403.2.6, C403.2.7.2,
Table C403.2.7.2, C403.4.5
FBC-FG—Fifth Edition (2014)Florida Building Code, Fuel GasC201.3
FBC-P—Fifth Edition (2014)Florida Building Code, Plumbing C201.3
FBC-R—Fifth Edition (2014)Florida Building Code, ResidentialC201.3, C202
FFPC—Fifth Edition (2014)Florida Fire Prevention CodeC201.3
FS—2013Florida StatutesC103.1.1.1.2, C103.1.1.2
IESNAIlluminating Engineering Society of North America
120 Wall Street, 17th Floor
New York, NY 10005-4001
Standard
reference
number
Title Referenced
in code
section number
ANSI/ASHRAE/IESNA
90.1—2010
Energy Standard for Buildings, Except Low-rise Residential Buildings C401.2, C401.2.1, C402.1.1,
Table C402.1.2, Table C402.2
ISOInternational Organization for Standardization
1, rue de Varembe, Case postale 56, CH-1211
Geneva, Switzerland
Standard
reference
number
TitleReferenced
in code
section number
ISO/AHRI/ASHRAE
13256-1 (2005)
Water-source Heat Pumps—Testing and Rating for Performance—
Part 1: Water-to-air and Brine-to-air Heat Pumps
Table C403.2.3(2)
ISO/AHRI/ASHRAE
13256-2 (1998)
Water-Source Heat Pumps—Testing and Rating for Performance—
Part 2: Water-to-water and Brine-to-water Heat Pumps
Table C403.2.3(2)
NAIMANorth American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310,
Alexandria, VA 22314
Standard
reference
number
TitleReferenced
in code
section number
NAIMA—2002Fibrous Glass Duct Construction Standards, Fifth EditionTable C403.2.7.2
NEBBNational Environmental Balancing Bureau
8575 Grovemont Circle
Gaithersburg, MD 20877-4121
Standard
reference
number
TitleReferenced
in code
section number
NEBB—2005Procedural Standards For Testing Adjusting Balancing of
Environmental Systems, Seventh Edition
C408.2.2.1
NFRCNational Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt, MD 20770
Standard
reference
number
TitleReferenced
in code
section number
100—2010Procedure for Determining Fenestration Products U-factorsC303.1.3, C402.2.1
200—2010Procedure for Determining Fenestration Product Solar Heat Gain Coefficients
and Visible Transmittance at Normal Incidence
C303.1.3, C402.3.1.1
400—2010Procedure for Determining Fenestration Product Air LeakageTable C402.4.3
SMACNASheet Metal and Air Conditioning Contractors National Association, Inc.
4021 Lafayette Center Drive
Chantilly, VA 20151-1209
Standard
reference
number
TitleReferenced
in code
section number
SMACNA—85HVAC Air Duct Leakage Test ManualTable C403.2.7.2, C403.2.7.3.7
SPRISingle Ply Roofing Industry
411 Waverley Oaks Road, Ste 331
Waltham, MA 02452
Standard
reference
number
TitleReferenced
in code
section number
ANSI/SPRI VF-1 2010External Fire Design Standard for Vegetative RoofsC407.5.2.4.1
ULUnderwriters Laboratories
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
TitleReferenced
in code
section number
181—05Standard for Factory-Made Air Ducts and Air Connectors with revisions
through December 1998
Table C403.2.7.2
181A—05Closure Systems for Use With Rigid Air Ducts and Air Connectors,
with revisions through December 1998
C403.2.7.3.7, Table C403.2.7.2
181B—05Closure Systems for Use With Flexible Air Ducts and Air Connectors with
revisions through May 2000
C403.2.7.3.7, Table C403.2.7.2
723—03Standard for Test for Surface Burning Characteristics of Building MaterialsC403.2.7.3.7
727—06Oil-fired Central Furnaces—with Revisions through April 2010Table C403.2.3(4), Table C406.2(4)
731—95Oil-fired Unit Heaters—with Revisions through April 2010Table C403.2.3(4), Table C406.2(4)
US-FTCUnited States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
Standard
reference
number
Title Referenced
in code
section number
CFR Title 16
(May 31, 2005)
R-value Rule C303.1.4
WDMAWindow and Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
Standard
reference
number
TitleReferenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
Table C402.4.3
Resources