ADOPTS WITH AMENDMENTS:

International Building Code 2018 (IBC 2018)

Heads up: There are no amended sections in this chapter.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

AA

Aluminum Association
1525 Wilson Boulevard, Suite 600
Arlington VA 22209

ADM1—2015

Aluminum Design Manual: Part 1—A Specification for Aluminum Structures

1604.3.5, 2002.1

ASM 35—00

Aluminum Sheet Metal Work in Building Construction (Fourth Edition)

2002.1

AAF

Aluminum Association of Florida, Inc.
3203 Lawton Road #110
Orlando FL 32803

AAF—20

Guide to Aluminum Construction in High Wind Areas (2020)

2002.4.1, 1622.1.2

AAMA

American Architectural Manufacturers Association
1827 Waldon Office Square, Suite 550
Schaumburg IL 60173

1402—09

Standard Specifications for Aluminum Siding, Soffit and Fascia

1404.5.1

AAMA/NSA 2100—19

Voluntary Specifications for Sunrooms

202, 2002.6.1, 2002.6.2

AAMA/WDMA/CSA 101/I.S.2/A440—08, 11 or 17

North American Fenestration Standard/Specifications for Windows, Doors and Skylights

1010.1.7, 1709.5.1, 2405.5, 2411.3.2.1

AAMA 450—10

Voluntary Performance Rating Method for Mulled Fenestration Assemblies

1709.8

AAMA 501—15

Methods of Test for Exterior Walls

1709.8.4

AAMA 506—16

Voluntary Specifications for Impact and Cycle Testing of Fenestration Products

1609.1.2

711—13 or 16

Voluntary Specification for Self-adhering Flashing Used for Installation of Exterior Wall Fenestration Products

1405.4, Table 1507.1.1.1, 1507.1.1.2, 1507.1.1.3

714—15

Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive Seal around Exterior Wall Openings in Buildings

1405.4

FMA/AAMA 100—12

Standard Practice for the Installation of Windows with Flanges or Mounting


FMA/AAMA 200—12

Standard Practice for the Installation of Windows with Frontal Flanges


FMA/WDMA 250—10

Standard Practice for the Installation of Non-Frontal Flange Windows with Mounting Flanges for Surface Barrier Masonry for Extreme Wind/Water Conditions


FMA/AAMA/WDMA300—12

Standard Practice for the Installation of Exterior Doors in Wood Frame Construction for Extreme Wind/Water Exposure


FMA/AAMA/WDMA 400-13

Standard Practice for the Installation of Exterior Doors in Surface Barrier Masonry Construction for Extreme Wind/Weather Exposure


ACI

American Concrete Institute
P.O. Box 9094
Farmington Hills MI 48333-9094

216.1—14

Code Requirements for Determining Fire Resistance of Concrete and Masonry Construction Assemblies

Table 721.1(2), 722.1

AF & PA

American Forest & Paper Association
1111 19th St, NW Suite 800
Washington DC 20036

AF&PA—92

Wood Structural Design Data

2314.4.7

AF&PA—05

Design Values for Joists and Rafters

2314.4.7

PWF—07

Permanent Wood Foundation (PWF) Design Specification

2314.4.7

AF&PA—12

Span Tables for Joists and Rafters

2314.4.7, 2317.1.1

WCD 1—01

Wood Construction Data No. 1, Details for Conventional Wood Frame Construction

2314.4.7

WCD 4—03

Wood Construction Data No. 4, Plank and Beam Framing for Residential Buildings

2314.4.7, 2306.1.2

WCD 5—89

Wood Construction Data No. 5, Heavy Timber Construction Details

2314.4.7, 2203.1, 2203.2, 2205.1, 2205.2.1.1, 2206.1

AHA

American Hardboard Association
1210 West N.W. Highway
Palatine IL 60067

A135.4—04

Basic Hardboard

1404.3.1, 2314.4.1

A135.5—04

Prefinished Hardboard Paneling

2314.4.1

A135.6—98

Hardboard Siding

2314.4.1

A194.1—85

Cellulosic Fiber Board

2314.4.1

IB Spec. No. 1

Recommended Product and Application Specification —Structural Insulating Roof Deck

2314.4.1

IB Spec. No. 2

Recommended Product and Application Specification —1/2 inch Fiberboard Nail-Base Sheathing

2314.4.1

IB Spec. No. 3

Recommended Product and Application Specification —1/2 inch Intermediate Fiberboard Sheathing

2314.4.1

AISC

American Institute of Steel
Construction One East Wacker Drive, Suite 700
Chicago IL 60601-18021

AISC DG09

Torsional Analysis of Structural Steel Members

2003, 2214.3

AISC—09

Detailing for Steel Construction

2214.3

AISC—2017

Steel Construction Manual, 2017

2214.3

AISC DG15—2018

Rehabilitation and Retrofit Guide A Reference for Historic Shapes and Specifications

2214.3

AISC DG03

Serviceability Design Considerations for Steel Buildings, 2003

2214.3

ANSI/AISC 341—16

Seismic Provisions for Structural Steel Buildings

1613.4.1, 2205.2.1.1, 2205.2.1.2, 2205.2.2, 2206.2.1

ANSI/AISC 360—16

Specification for Structural Steel Buildings

722.5.2.2.1, 1604.3.3, 2203.1, 2203.2, 2205.1, 2205.2.1.1, 2206.1

AISI

American Iron and Steel Institute
25 Massachusetts Avenue, NW Suite 800
Washington DC 20001

AISI S100—16

North American Specification for the Design of Cold-formed Steel Structural Members

1604.3.3, 1905.1.8, 2203.1, 2203.2, 2210.1, 2210.2, 2214.3

AISI S202—15

Code of Standard Practice for Cold-formed Steel Framing, 2015


AISI S220—15

North American Standard for Cold-formed Steel Framing-Nonstructural Members, 2015

2203.1, 2203.2, 2211.1, 2211.2, 2214.3, Table 2506.2, Table 2507.2

AISI S230—19

Standard for Cold-formed Steel Framing-Prescriptive Method for One- and Two-family Dwellings, 2019

1609.1.1, 1609.1.1.1, 2211.1.2, 2214.3

AISI S240—15

AISI S240, North American Standard for Cold-formed Steel Structural Framing, 2015

2203.1, 2203.2, 2211.1, 2214.3, 2211.1.1.1, Table 2506.2, Table 2507.2, Table 2603.12.1

(S299—16) AISI S400—15/S1—16

North American Standard for Seismic Design of Cold-formed Steel Structural Systems, 2015, with Supplement 1, dated 2016

2210.2, 2211.1.1.1, 2211.1.1.2

AISI S913—17

Test Standard for Hold-Downs Attached to Cold-Formed Steel Structural Framing

2210.3

AISI S914—17

Test Standard for Joist Connectors Attached to Cold-Formed Steel Structural Framing

2210.3

AITC

American Institute of Timber Construction
333 West Hampden Avenue
Englewood CO 80110

A 190.1—07

Structural Glued Laminated Timber

2314.4.2

Technical Note 7—96

Calculation of Fire Resistance of Glued Laminated Timbers

2314.4.2

104—03

Typical Construction Details

2306.1, 2314.4.2

106

Code of Suggested Practices

2314.4.2

108—93

Standard for Heavy Timber Construction

2314.4.2

109—98

Standard for Preservative Treatment for Structural Glued Laminated Timber

2314.4.2

110—01

Standard Appearance Grades for Structural Glued Laminated Timber

2306.1, 2314.4.2

112—93

Tongue-and-Groove Heavy Timber Roof Decking

2314.4.2

113—10

Dimensions of Structural Glued Laminated Timber

2306.1, 2314.4.2

117—10

Standard Specifications for Structural Glued Laminated Timber of Softwood Species—Design Requirements—Standard Specifications for Structural Glued Laminated Timber of Softwood Species—Manufacturing Requirements

2314.4.2

119—96

Standard Specifications for Structural Glued Laminated Timber of Hardwood Species

2306.1, 2314.4.2

ALI

Automotive Lift Institute
P.O. Box 85
Courtland NY 13045

ALI ALCTV—2017

Standard for Automotive Lifts—Safety Requirements for Construction, Testing and Validation (ANSI)

3001.2, Table 3001.2

AMCA

Air Movement and Control Association International
30 West University Drive
Arlington Heights IL 60004

540—13

Test Method for Louvers Impacted by Wind Borne Debris

1609.1.2.1, 1626.5.1, 1626.5.2, 1626.5.3

ANSI

American National Standards Institute
25 West 43rd Street, Fourth Floor
New York NY 10036

A13.1—2015

Scheme for the Identification of Piping Systems

415.11.6.5

A41.1

Building Code Requirements for Masonry

2121.2.8

A108.1A—16

Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar

2103.2.3

A108.1B—99

Installation of Ceramic Tile, quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex-Portland Mortar

2103.2.3

A108.4—99

Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive

2103.2.3.6

A108.5—99

Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-Portland Cement Mortar

2103.2.3.1, 2103.2.3.2

A108.6—99

Installation of Ceramic Tile with Chemical-resistant, Water Cleanable Tile-setting and -grouting Epoxy

2103.2.3.3

A108.8—99

Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout

2103.2.3.4

A108.9—99

Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout

2103.2.3.5

A108.10—99

Installation of Grout in Tilework

2103.2.3.7

A117—2015

Structural Glued Laminated Timber of Softwood Species

2306.1, 2314.4.3

A118.1—16

American National Standard Specifications for Dry-set Portland Cement Mortar

2103.2.3.1

A118.3—13

American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive

2103.2.3.3

A118.4—16

American National Standard Specifications for Latex-Portland Cement Mortar

2103.2.4, 2103.2.3.2

A118.5—99

American National Standard Specifications for Chemical Resistant Furan Mortar and Grouts for Tile Installation

2103.2.3.4

A118.6—10

American National Standard Specifications for Cement Grouts for Tile Installation

2103.2.3.7

A118.8—99

American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout

2103.2.3.5

A136.1—08

American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile

2103.2.3.6

A137.1—17

American National Standard Specifications for Ceramic Tile

202

ANSI/A190.1—17

Structural Glued Laminated Timber

2303.1.3, 2306.1, 2314.4.3

ANSI B18.6.1-81(2016)

Wood Screws (Inch Series)

1506.6

Z535.1

American National Standard Safety Color Code for Making Physical Hazards

453.4.6, 453.14.6

Z358.1

Emergency Eyewash and Shower Equipment

450.3.11.7

Z97.1—14

Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test

1618.4.6.3, 2406.1.2, 2406.2, Table 2406.2(2), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.2, 2409.3, 2409.4.1

APA

APA - Engineered Wood Association
7011 South 19th
Tacoma WA 98466

ANSI 117—2015

Structural Glued Laminated Timber of Softwood Species

2306.1, 2314.4.3

ANSI/A 190.1—2017

Structural Glued Laminated Timber

2303.1.3, 2306.1

ANSI/APA PRP 210—2014

Standard for Performance-Rated Engineered Wood Siding

2303.1.5, 2304.7, 2306.3, Table 2306.3(1)

ANSI/APA PRR 410—2016

Standard for Performance-Rated Engineered Wood Rim Boards

2303.1.13

APA PDS—12

Panel Design Specification

2306.1, 2314.4.3

APA PDS Supplement 1—12

Design and Fabrication of Plywood Curved Panels (revised 2013)

2306.1, 2314.4.3

APA PDS Supplement 2—12

Design and Fabrication of Plywood-lumber Beams (revised 2013)

2306.1, 2314.4.3

APA PDS Supplement 3—12

Design and Fabrication of Plywood Stressed-skin Panels (revised 2013)

2306.1, 2314.4.3

APA PDS Supplement 4—12

Design and Fabrication of Plywood Sandwich Panels (revised 2013)

2306.1, 2314.4.3

APA PDS Supplement 5—16

Design and Fabrication of All-plywood Beams

2306.1, 2314.4.3

APA B840—16

303 Siding Manufacturing Specifications

2314.4.3

APA L350—07

Design/Construction Guide Diaphragms and Shearwalls

2314.4.3

APA PRP-108—18

Performance Standards and Policies for Wood Structural Panels

2314.4.3

APA V910—90

Plywood Folded Plate Laboratory Report 121

2314.4.3

APA EWCG

Engineered Wood Construction Guide, Form E30

2314.4.3

APA R540—13

Builders Tips: Proper Storage and Handling of Glulam Beams

2306.1

APA S475—16

Glued Laminated Beam Design Tables

2306.1

APA S560—14

Field Notching and Drilling of Glued Laminated Timber Beams

2306.1

APA T300—16

Glulam Connection Details

2306.1

APA X440—17

Product and Application Guide: Glulam

2306.1

APA X450—18

Glulam in Residential Building Construction Guide-Western Edition

2306.1

APA E30—16

Engineered Wood Construction Guide

2314.4.3

APSP

Association of Pool and Spa Professionals
2111 Eisenhower Avenue, Suite 500
Alexandria VA 22314

ANSI/APSP/ICC 3—14

American National Standard for Permanently Installed Residential Spas and Swim Spas

454.2.6.1

ANSI/APSP/ICC 4—12

American National Standard for Aboveground /Onground Residential Swimming Pools Includes Addenda A Approved April 4, 2013

454.2.6.1

ANSI/APSP/ICC 5-11

American National Standard for Residential Inground Swimming Pools

454.2.6.1

ANSI/APSP/ICC 6—13

American National Standard for Residential Portable Spas and Swim Spas

454.2.6.1

ANSI/APSP/ICC 7—13

American National Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs, and Catch Basins

454.2.6.1, 454.2.6.3, 454.2.6.6

ANSI/APSP 16—2017

American National Standard for Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs

454.1.6.5.12

ASABE

American Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph MI 49085

EP 484.3 (R2008) MON 2016

Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings

2306.1

EP 486.2 OCT 2012 ED

Shallow-post and Pier Foundation Design

2306.1

EP 559.1 MON (2010)2014

Design Requirements and Bending Properties for Mechanically Laminated Wood Assemblies

2306.1

ASCE/SEI

American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston VA 20191-4400

8—02

Specification for the Design of Cold-formed Stainless Steel Structural Members

1604.3.3, 2210.1, 2210.2, 2214.3

19—16

Structural Applications of Steel Cables for Buildings

2208.1

24—14

Flood Resistant Design and Construction

453.4.2, 1203.4.2, 1603.1.7, 1612.4, 1612.4.1, 1612.4.2, 1612.5, 2702.1.7, 3001.2, 3109.2, 3109.3, 3109.3.2.1, 3109.3.3, 3109.3.4

29—2014

Standard Calculation Methods for Structural Fire Protection

722.1

32—01

Design and Construction of Frost Protected Shallow Foundations

1809.5

49—12

Wind Tunnel Testing for Buildings and Other Structures

1609.1.1

ASHRAE

ASHRAE, Inc.
1791 Tullie Circle NE
Atlanta GA 30329-2305

62—01

Ventilation for Acceptable Indoor Air Quality

C502.1, E306.1

ANSI/ASHRAE/ASJHE 170—08

Ventilation of Heath Care Facilities

450.3.14, 450.3.14.4, 469.4.12.1

ASME

American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016-5990

ASME/A17.1—2016/CSA B44—16

Safety Code for Elevators and Escalators

469.4.9.1, 907.3.3, 911.1.6, 1607.9.1, 3001.2, 3001.1, Table 3001.2, 3001.4, 3001.6, 3002.5, 3002.10, 3003.2, 3007.1, 3008.1.3, 3008.7.1, 3010.1.3, 3012.1

A17.3—2015

Safety Code for Existing Elevators and Escalators

469.4.9.1, 3001.1, 3001.2, 3001.5.3, 3010.1.3, 3012.1

ASME A17.6-2010

Standard for Elevator Suspension, Compensation, and Governor Systems Safety

Table 3001.2

A17.7—2007/CSA B44—07 (R2012)

Performance-Based Safety Code for Elevators and Escalators

Table 3001.2

A18.1—2017

Safety Standard for Platform Lifts and Stairway Chairlifts

3001.1, Table 3001.2, 3012.1

A90.1—2015

Safety Standard for Belt Manlifts

Table 3001.2, 3001.6

A112.19.8

Suction Fittings for Use in Swimming Pools, Wading Pools, spas, Hot Tubs, and Whirlpool Bathtub Appliances

454.1.6.5.3.2.3

A120.1—01

Safety Requirements for Powered Platforms for Building Maintenance

3001.6

B16.18—2012

Cast Copper Alloy Solder Joint Pressure Fittings

909.13.1

B16.22—2013

Wrought Copper and Copper Alloy Solder Joint Pressure Fittings

909.13.1

B20.1—2015

Safety Standard for Conveyors and Related Equipment

Table 3001.2, 3001.6, 3004.3

B31.3—2016

Process Piping

415.11.6

18.6.1—81(2016)

Wood Screws (Inch Series)

1506.6

A13.1—2015

Scheme for the Identification of Piping Systems

415.11.6.5

ASSE

American Society of Safety Engineers
1800 East Oakton Street
Des Plaines IL 60018

ANSI/ASSE Z359.1-2016

Requirements for the ANSI/ASSE Z359 Fall Protection Code

1015.6, 1015.7

ASTM

100 Barr Harbor Drive
West Conshohocken PA 19428-2959

A6/A6M—14

Standard Specification for General Requirements for Rolled Structural Steel Bars, Plates, Shapes and Sheet

1810.3.2.3, 1810.3.5.3.1, 1810.3.5.3.3, 2214.3

A36/A36M—14

Specification for Carbon Structural Steel

1810.3.2.3

A90/A90M—13

Standard Test Method for Weight (Mass) of Coating on Iron and Steel Articles with Zinc or Zinc Alloy Coatings

1506.7

A153/A153M—09

Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware

2304.10.5

A240/A240M—(2015b)

Standard Specification for Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and General Applications

1506.7, Table 1507.4.3(1)

A252—10

Specification for Welded and Seamless Steel Pipe Piles

1810.3.2.3

A283/A283M—13

Specification for Low and Intermediate Tensile Strength Carbon Steel Plates

1810.3.2.3

A361

Specification for Steel Sheet Zinc-Coated (Withdrawn)

2319.17.1.1

A416/A416M—15

Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete

1810.3.2.2

A446

Specification for Steel Sheet, Zinc-coated (Galvanized) by the Hot-Dip Process, Structural (Physical) Quality

1917.4.3

A463/A463M—15

Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process

Table 1507.4.3(2)

A525—87

Specification for General Requirements for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process

1917.4.3

A572/A572M—15

Specification for High-strength Low-alloy Columbium-Vanadium Structural Steel

1810.3.2.3

A588/A588M—15

Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point with Atmospheric Corrosion Resistance

1810.3.2.3

A611

Standard Specification for Structural Steel (SS), Sheet, Carbon, Coil-Rolled

1917.4.3

A615/A615M—15ae1

Specification for Deformed and Plain Carbon-steel Bars for Concrete Reinforcement

1810.3.10.2

A641/A641M—14

Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire

1506.6

A653/A653M—15

Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process

Table 1507.4.3(1), Table 1507.4.3(2), 2304.10.5.1, 2319.17.2.2.7

A690/A690M—13a

Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel H-piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Marine Environments

1810.3.2.3

A706/A706M—15

Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement

2107.3

A722/A722M—15

Specification for High-strength Steel Bar for Prestressing Concrete

1810.3.10.2

A755/A755M—15

Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products

Table 1507.4.3(1), Table 1507.4.3(2)

A792/A792M—10(2015)

Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process

Table 1507.4.3(1), Table 1507.4.3(2)

A875/A875M—13

Standard Specification for Steel Sheet Zinc-5 percent, Aluminum Alloy-coated by the Hot-dip Process

Table 1507.4.3(2)

A924/A924M—14

Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process

Table 1507.4.3(1), 2319.17.1.1, 2319.17.2.2.7

A1003/A1003M—15

Standard Specification for Sheet Steel, Carbon, Metallic, and Non-metallic Coated for Cold-formed Steel Framing Members

2214.3

A1064A/A1064M—16a

Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete

1907.2

B42—2015A

Specification for Seamless Copper Pipe, Standard Sizes

909.13.1

B43—15

Specification for Seamless Red Brass Pipe, Standard Sizes

909.13.1

B68/B68M—11

Specification for Seamless Copper Tube, Bright Annealed (Metric)

909.13.1

B88—14

Specification for Seamless Copper Water Tube

909.13.1

B101—12

Specification for Lead-coated Copper Sheet and Strip for Building Construction

1404.5.3, Table 1507.4.3(1)

B117—16

Standard Practice for Operating Salt Spray (Fog) Apparatus

1506.6

B209—14

Specification for Aluminum and Aluminum Alloy Steel and Plate

Table 1507.4.3(1)

B251—10

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

909.13.1

B280—13

Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

909.13.1

B370—12

Specification for Copper Sheet and Strip for Building Construction

1404.5.2, Table 1507.4.3(1)

B695—04(2009)

Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel Strip for Building Construction

2304.10.5.1, 2304.10.5.3

C5—10

Specification for Quicklime for Structural Purposes

Table 2507.2

C22/C22M-00(2015)

Specification for Gypsum

Table 2506.2

C27—98(13)

Specification for Classification of Fireclay and High-alumina Refractory Brick

2111.6

C28/C28M—10(2015)

Specification for Gypsum Plasters

Table 2507.2

C31/C31M—15

Practice for Making and Curing Concrete Test Specimens in the Field


C33/C33M—13

Specification for Concrete Aggregates

722.3.1.4, 722.4.1.1.3

C35/C35M-1995(2014)

Specification for Inorganic Aggregates for Use in Gypsum Plaster

Table 2507.2

C55—2014A

Specification for Concrete Building Brick

Table 722.3.2

C59/C59M—00 (2015)

Specification for Gypsum Casting Plaster and Molding Plaster

Table 2507.2

C61/C61M—00 (2015)

Specification for Gypsum Keene's Cement

Table 2507.2

C62—13A

Standard Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)

1807.1.6.3

C67—14

Test Methods of Sampling and Testing Brick and Structural Clay Tile


C73—14

Specification for Calcium Silicate Brick (Sand-lime Brick)

Table 722.3.2

C90—14

Specification for Loadbearing Concrete Masonry Units

Table 722.3.2, 1807.1.6.3, 2109.3

C91/C91M—12

Specification for Masonry Cement

Table 2507.2

C94/C94M—15A

Specification for Ready-Mixed Concrete

E202, E303.2.1

C140/C140M—15

Test Method Sampling and Testing Concrete Masonry Units and Related Units

722.3.1.2

C150/C150M—15

Specification for Portland Cement

1903.1, Table 2507.2

C172/C172M—14A

Practice for Sampling Freshly Mixed Concrete

E303.2.4

C199—84 (2011)

Test Method for Pier Test for Refractory Mortars

2111.6, 2111.9, 2113.12

C206—14

Specification for Finishing Hydrated Lime

Table 2507.2

C208—12

Specification for Cellulosic Fiber Insulating Board

Table 1508.2, 2303.1.6

C216—15

Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)

Table 721.1(2), 1807.1.6.3

C270—14A

Specification for Mortar for Unit Masonry


C315—07(2011)

Specification for Clay Flue Liners and Chimney Pots

2111.9, 2113.11.1, Table 2113.16(1)

C317/C317M—00(2015)

Specification for Gypsum Concrete

2514.1

C330/C330M—14

Specification for Lightweight Aggregates for Structural Concrete

202

C331/C331M—2014

Specification for Lightweight Aggregates for Concrete Masonry Units

722.3.1.4, 722.4.1.1.3

C332—09

Specification for Lightweight Aggregates for Insulating Concrete

1917.4.5

C406/C406M—15

Specification for Roofing Slate

1507.7.5

C472—99(2014)

Specification for Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete

Table 2506.2

C473—15

Test Method for Physical Testing of Gypsum Panel Products

Table 2506.2

C474—15

Test Methods for Joint Treatment Materials for Gypsum Board Construction

Table 2506.2

C475/C475M—15

Specification for Joint Compound and Joint Tape for Finishing Gypsum Board

Table 2506.2

C476—19

Standard Specification for Grout for Masonry

2122.8.2

C494/C494M—99

Standard Specification for Chemical Admixtures for Concrete

1917.4.4, E202, E303.2.4

C495—99a

Standard Test Method for Compressive Strength of Lightweight Insulating Concrete

Table 1508.2, 1917.1.1, 1917.1.2, 1917.1.3

C509—00

Elastomeric Cellular Preformed Gaskets and Sealing Material

2411.3.4

C513

Standard Test Method for Obtaining and Testing Specimens of Hardened Lightweight Insulating Concrete for Compressive Strength

Table 1508.2

C514—04(2014)

Specification for Nails for the Application of Gypsum Board

Table 721.1(2), Table 721.1(3), Table 2506.2

C516—08(2014)E1

Specifications for Vermiculite Loose Fill Thermal Insulation

722.3.1.4, 722.4.1.1.3

C547—15

Specification for Mineral Fiber Pipe Insulation

Table 721.1(2), Table 721.1(3)

C549—06(2012)

Specification for Perlite Loose Fill Insulation

722.3.1.4, 722.4.1.1.3

C552—15

Standard Specification for Cellular Glass Thermal Insulation

Table 1508.2

C557—03(2009)e01

Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing

Table 2506.2, 2508.4

C578—15

Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation

Table 1508.2, 1917.4.10, 2603.10, Table 2603.12.1, Table 2603.12.2

C587—04(2014)

Specification for Gypsum Veneer Plaster

Table 2507.2

C595/C595—14E1

Specification for Blended Hydraulic Cements

1903.1, Table 2507.2

C618-12a

Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete

1917.4.4

C631—09(2014)

Specification for Bonding Compounds for Interior Gypsum Plastering

Table 2507.2

C635/C635M—13A

Specification for the Manufacture, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings

808.1.1.1, 2506.2.1

C636/C636M—13

Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels

808.1.1.1

C645—14

Specification for Nonstructural Steel Framing Members

2319.17.1.3

C652—15

Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)

1807.1.6.3

C726—12

Standard Specification for Mineral Roof Insulation Board

Table 1508.2

C728—15

Standard Specification for Perlite Thermal Insulation Board

Table 1508.2

C744—14

Specification for Prefaced Concrete and Calcium Silicate Masonry Units

Table 722.3.2

C754—15

Specification for Installation of Steel Framing Members to Receive Screw-attached Gypsum Panel Products

Table 2508.1, Table 2511.1.1

C794—01

Standard Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants

2415.4

C796—97

Standard Test Method for Foaming Agents For Use in Producing Cellular Concrete Using Performed Foam

Table 1508.2, 1917.1.2, 1917.1.3, 1917.4.5

C836/C836M—15

Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course

1507.15.2

C840—13

Specification for Application and Finishing of Gypsum Board

Table 2508.1, 2509.2

C841—03(2013)

Specification for Installation of Interior Lathing and Furring

Table 2508.1, Table 2511.1.1

C842—05(2015)

Specification for Application of Interior Gypsum Plaster

Table 2511.1.1, 2511.3, 2511.4

C843—99 (2012)

Specification for Application of Gypsum Veneer Plaster

Table 2511.1.1

C844—2015

Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster

Table 2508.1

C847—14A

Specification for Metal Lath

Table 2507.2

C864—05

Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers

2411.3.4

C869—11

Specification for Foaming Agents Used in Making Preformed Foam for Cellular Concrete

Table 1508.2, 1917.4.5

C887—13

Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar

1805.2.2, 2103.2.2

C897—15

Specification for Aggregate for Job-Mixed Portland Cement-based Plaster

Table 2507.2

C920—14A

Standard for Specification for Elastomeric Joint Sealants

2415.4, Table 2506.2, B303.6, E303.3.1

C926—18b

Specification for Application of Portland Cement-based Plaster

2510.3, Table 2511.1.1, 2511.3, 2511.4, 2512.1, 2512.1.2, 2512.2, 2512.6, 2512.8.2, 2512.9, 2513.7

C932—06(2013)

Specification for Surface-applied Bonding Compounds for Exterior Plastering

Table 2507.2

C933—14

Specification for Welded Wire Lath

Table 2507.2

C946—10

Specification for Construction of Dry-stacked, Surface-bonded Walls

2103.2.2

C954—15

Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to 0.112 inch (2.84 mm) in Thickness

Table 2506.2, Table 2507.2

C956—04(2015)

Specification for Installation of Cast-in-place Reinforced Gypsum Concrete

2514.1

C957/C957M—15

Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane with Integral Wearing Surface

1507.15.2

C1007—11a(2015)

Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories

Table 2508.1, Table 2511.1.1

C1029—15

Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation

1507.14.2

C1032—14

Specification for Woven Wire Plaster Base

Table 2507.2

C1036—01

Specification for Flat Glass

2411.1.2

C1047—2014a

Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base

Table 2506.2, Table 2507.2

C1048—97b

Standard Specification for Heat-Treated Flat Glass—Kind HS, Kind FT Coated and Uncoated Glass

2411.1.5

C1063—19a

Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster

2510.3, Table 2511.1.1, 2512.1.1

C1088—14

Specification for Thin Veneer Brick Units Made from Clay or Shale

Table 721.1(2)

C1115—00

Dense Elastomeric Silicone Rubber Gaskets and Accessories

2411.3.4

C1157/C1157M—11

Standard Performance Specification for Hydraulic Cement

1903.1, Table 2507.2

C1167—11

Specification for Clay Roof Tiles

1507.3.4, 1523.6.5.2

C1177/C1177M—13

Specification for Glass Mat Gypsum Substrate for Use as Sheathing

Figure 722.5.1(2), Figure 722.5.1(3), Table 1508.2, Table 2506.2

C1178/C1178M—13

Specification for Coated Mat Water-resistant Gypsum Backing Panel

Figure 722.5.1(2), Figure 722.5.1(3), Table 2506.2, Table 2509.2

C1186—08(2012)

Specification for Flat Fiber Cement Sheets

1404.10, 1405.16.1, 1405.16.2

C1225—08 (2012)

Specification For Fiber-Cement Roofing Shingles, Shakes and Slates

1518.5.1

C1261—13

Specification for Firebox Brick for Residential Fireplaces

2111.6, 2111.9

C1278/C1278M—07a(2011)

Specification for Fiber-reinforced Gypsum Panels

Figure 722.5.1(2), Figure 722.5.1(3), Table 1508.2, Table 2506.2

C1280—13A

Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing

Table 2508.1, 2508.2

C1283—11

Practice for Installing Clay Flue Lining

2113.9.1, 2113.12

C1288—14

Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets

Table 2509.2

C1289—15

Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board

Table 1508.2, 2603.10, Table 2603.12.1, Table 2603.12.2

C1314—07

Specification for Test Method for Compressive Strength of Masonry Prisms

2122.3

C1325—14

Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Backer Units

Table 2509.2

C1328/C1328M—12

Specification for Plastic (Stucco Cement)

Table 2507.2

C1364—10B

Standard Specification for Architectural Cast Stone

2103.1

C1396M/C1396M—2014A

Specification for Gypsum Board

Figure 722.5.1(2), Figure 722.5.1(3)

C1492—03(2009)

Standard Specification for Concrete Roof Tile

1507.3.5

C1600/C1600M—11

Standard Specification for Rapid Hardening Hydraulic Cement

Table 2507.2

C1629/C1629M—15

Standard Classification for Abuse-resistant Nondecorated Interior Gypsum Panel Products and Fiber-reinforced Cement Panels

403.2.3.1, 403.2.3.2, 403.2.3.4

C1658/C1658M—13

Standard Specification for Glass Mat Gypsum Panels

Figure 722.5.1(2), Figure 722.5.1(3), Table 2506.2

C1670—16

Standard Specification for Adhered Manufactured Stone Masonry Veneer Units

2103.1

C1766—13

Standard Specification for Factory-laminated Gypsum Panel Products

Table 2506.2

D25—12

Specification for Round Timber Piles

1810.3.2.4, 2303.1.12

D41/D41M—2011

Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing

1514.2.3.1, 1517.6.2.4, 1519.6, 1521.6, 1521.14.1, Table 1507.10.2

D43/D43M—2000(2012)E1

Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing

1514.2.3.1, 1517.6.2.4, 1519.6, 1521.6, 1521.14.2, Table 1507.10.2

D56—05(2010)

Test Method for Flash Point By Tag Closed Cup Tester

202

D86—15

Test Method for Distillation of Petroleum Products at Atmospheric Pressure

202

D92—12b

Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester

1519.2.2

D93—15

Test Method for Flash Point By Pensky-Martens Closed Cup Tester

202

D225—07

Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules

1507.2.5

D226/D226M—09

Specification for Asphalt-saturated Organic Felt Used in Roofing and Waterproofing

1404.2, 1505.2, 1507.1.1, 1507.1.1.1, 1507.2.3, 1507.3.3, 1507.5.3, 1507.6.3, 1507.7.3, 1507.8.3, 1507.9.3, Table 1507.10.2, 1507.17.3, 1518.4

D227/D227M—03(2011)E1

Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing

Table 1507.10.2

D256—03

Standard Test Methods for Determining the Izod Pendulum Impact Resistance of Plastics

2615.2

D312/D312M—15

Specification for Asphalt Used in Roofing

Table 1507.10.2, 1519.3, Table 1519.3A, 1519.4, 1521.14.1

D412—98a (2002)e1

Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension

2415.4

D422—63 (2007) E2

Test Method for Particle-size Analysis of Soils

1803.5.3

D448—2012

Standard Classification for Sizes of Aggregate for Road and Bridge Construction

1507.12.3, 1507.13.3, E403.3

D450/D450M—07(2013)E1

Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing

Table 1507.10.2, Table 1519.3B

D624—00e1

Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers

2415.4

D635—14

Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position

2606.4

D638—03

Test Method for Tensile Properties of Plastics

2614.2, 2615.2

D1079—02

Standard Terminology Relating to Roofing, Waterproofing, and Bituminous Materials

1513.1

D1143/D1143M—07(2013)

Test Method for Deep Foundations Under Static Axial Compressive Load

1810.3.3.1.2

D1227—13

Specification for Emulsified Asphalt Used as a Protective Coating for Roofing

Table 1507.10.2, 1507.15.2

D1557—2012 E1

Test Method for Laboratory Compaction Characteristics of Soil Using Modified Effort [56,000 ft-lb/ft3 (2,700 KN m/m3)]

J107.5, J111, 1804.5, 1804.6

D1621

Standard Test Method for Compressive Properties of Rigid Cellular Plastics

1523.6.5.2.17.1

D1622

Standard Test Method for Apparent Density of Rigid Cellular Plastics

1523.6.5.2.17.2

D1623

Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

1523.6.5.2.17.3

D1761—06

Test Method for Mechanical Fasteners in Wood

2314.4.4

D1863/D1863M—05(2011)E1

Specification for Mineral Aggregate Used on Built-up Roofs

1504.8, Table 1507.10.2, 1519.12.1

D1929—16

Standard Test Method for Determining Ignition Temperature of Plastics

402.6.4.4, 406.7.2, 1409.11.2.1, 2606.4

D1970/D1970M—2015a

Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection

1507.1.1, 1507.1.1.1, 1507.1.1.2, 1507.1.1.3, 1507.2.4, 1507.2.9.2

D2126

Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging

1523.6.5.2.17.4

D2178/D2178M—15

Specification for Asphalt Glass Felt Used in Roofing and Waterproofing

Table 1507.10.2

D2240—03

Standard Test Method for Rubber Property—Durometer Hardness

2415.4

D2487—2011

Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)

Table 1610.1, 1803.5.1

D2565—99(2008)

Standard Practice for Xenon Arc Exposure of Plastics Intended for Outdoor Applications

2615.2

D2626/D2626M—04(2012)E1

Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing

1507.3.3, Table 1507.10.2, 1518.4

D2822/D2822M-05(2011)E1

Specification for Asphalt Roof Cement, Asbestos Containing

Table 1507.10.2

D2823/D2823M—05(2011)E1

Specification for Asphalt Roof Coatings, Asbestos Containing

Table 1507.10.2

D2824/D2824M—2013

Standard Specification for Aluminum-Pigmented Asphalt Roof Coating, Nonfibered, and Fibered without Asbestos

Table 1507.10.2

D2842

Standard Test Method for Water Absorption of Rigid Cellular Plastics

1523.6.5.2.17.6

D2843—16

Standard Test Method for Density of Smoke from the Burning or Decomposition of Plastics

2606.4

D2856

Standard Test Method for Open-cell Content of Rigid Cellular Plastics by the Air-Pycnometer

1523.6.5.2.17.5

D2859—16

Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials

804.4.1, 804.4.2

D2898—10

Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing

1505.1, 1516.1, 2303.2.4, 2303.2.6, 2314.4.4

D3018

Standard Specification for Class A Asphalt Shingles Surfaced with Mineral Granules

1523.6.5.1

D3019—08

Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered

Table 1507.10.2

D3161/D3161M—16

Test Method for Wind Resistance of Steep Slope Roofing Products (Fan Induced Method)

1504.3.3, Table 1504.3.3, 1507.2.7.1, Table 1507.2.7.1, 1507.17.8

D3200—74 (2012)

Standard Specification and Test Method for Establishing Recommended Design Stresses for Round Timber Construction Poles

2303.1.12

D3201/D3201M—2013

Test Method for Hygroscopic Properties of Fire-retardant-treated Wood and Wood-based Products

2303.2.7, 2314.4.4

D3278—1996 (2011)

Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus

202

D3462/D3462M—10A

Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules

1507.2.5, 1523.6.5.1

D3468/D3468—99 (2013)E1

Specification for Liquid-applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing

1507.15.2

D3498—03

Standard Specifications for Adhesives for Field-Gluing Plywood to Lumber Framing for Floor Systems

2314.4.4, 2322.1.5

D3679—17

Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding

1404.9, 1405.14

D3689/D3698M—2013E1

Test Methods for Deep Foundations Under Static Axial Tensile Load

1810.3.3.1.5

D3737—2012

Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam)

2303.1.3

D3746—85 (2015)

Test Method for Impact Resistance of Bituminous Roofing Systems

1504.7, 1515.2.4

D3747—79 (2007)

Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation

Table 1507.10.2

D3787—89

Test Method for Bursting Strength of Textiles-Constant-Rate-of-Traverse (CRT) Ball Burst Test

454.2.17.1.15

D3909/D3909M—14

Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules

1507.2.9.2, 1507.6.5, Table 1507.10.2

D3957—09

Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings

2303.1.11

D4022/D4022M—2007(2012)E1

Specification for Coal Tar Roof Cement, Asbestos Containing

Table 1507.10.2

D4086

Standard Practice for Visual Evaluation of Metamerism

454.1.2.4, 454.1.11.3

D4272—15

Test Method for Total Energy Impact of Plastic Films by Dart Drop

1504.7, 1515.2.4

D4318—10E1

Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils

1803.5.3

D4402

Viscosity Determinations of Unfilled Asphalt Using the Brookfield Thermoset Apparatus

1519.2.3

D4434/D4434M—12

Specification for Poly (Vinyl Chloride) Sheet Roofing

1507.13.2

D4479/D4479M—07(2012)E1

Specification for Asphalt Roof Coatings-Asbestos-free

Table 1507.10.2

D4533(2015)

Standard Test Method for Trapezoid Tearing Strength of Geo Textiles

1507.1.1.1

D4586/D4586M—07(2012)E1

Specification for Asphalt Roof Cement-Asbestos-free

Table 1507.10.2

D4601/D4601M—04(2012)E1

Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing

Table 1507.10.2

D4637/D4637M—14e1

Specification for EPDM Sheet Used in Single-ply Roof Membrane

1507.12.2

D4829—11

Test Method for Expansion Index of Soils

1803.5.3

D4869/D4869M—2016

Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing

1507.1.1, 1507.1.1.1, 1507.1.1.2, 1507.1.1.3, 1507.2.3, 1507.5.3, 1507.6.3, 1507.7.3, 1507.8.3, 1507.9.3, 1507.17.3

D4897/D4897M—01(2009)

Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing

Table 1507.10.2

D4945—12

Test Method for High-strain Dynamic Testing of Deep Foundations

1810.3.3.1.2

D4990—97a (2013)

Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing

Table 1507.10.2

D5019—07a

Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane

1507.12.2

D5034—95

Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)

454.2.17.1.15

D5055—13E1

Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists

2303.1.2

D5456—14B

Specification for Evaluation of Structural Composite Lumber Products

2303.1.10

D5516—09

Test Method of Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures

2303.2.5.1

D5643/D5643M—06(2012)E1

Specification for Coal Tar Roof Cement, Asbestos-free

Table 1507.10.2

D5664—10

Test Methods for Evaluating the Effects of Fire-retardant Treatment and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber

2303.2.5.2

D5665/D5665M—2014E1

Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing

Table 1507.10.2

D5726—98 (2013)

Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing

Table 1507.10.2

D5957—98

Standard Guide for Flood Testing Horizontal Waterproofing Installation

1519.16.6

D6083—18

Specification for Liquid Applied Acrylic Coating Used in Roofing

Table 1507.10.2, Table 1507.14.3, 1507.15.2, 1523.6.2.1.1, 1523.6.3.1, 1523.6.5.2.12.2

D6162/D6162M—2000A (2015)E1

Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements

1507.11.2

D6163/D6163M—2000(2015)E1

Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements

1507.11.2

D6164/D6164M—11

Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Metal Materials Using Polyester Reinforcements

1507.11.2

D6222/D6222M—11

Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements

1507.11.2

D6223/D6223M—02(2009)E1

Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements

1507.11.2

D6298—13

Specification for Fiberglass Reinforced Styrene-butadiene-styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface

1507.11.2

D6305—08(2015)E1

Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing

2303.2.5.1

D6380/D6380—03 (2013)E1

Standard Specification for Asphalt Roll Roofing (Organic) Felt

1507.2.9.2, 1507.3.3, 1507.6.5

D6464—03a(2009)e1

Standard Specification for Expandable Foam Adhesives for Fastening Gypsum Wallboard to Wood Framing

2508.4, Table 2506.2

D6509/D6509M—09(2015)

Standard Specification for Atactic Polypropylene (APP) Modified Bituminous Base Sheet Materials Using Glass Fiber Reinforcements

1507.11.2

D6694/D6694M—08(2013)E1

Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems

Table 1507.14.3, 1507.15.2

D6754/D6745M—15

Standard Specification for Ketone Ethylene Ester Based Sheet Roofing

1507.13.2

D6757—2016

Specification for Inorganic Underlayment for Use with Steep Slope Roofing

1507.1.1, 1507.2.3, 1507.17.3

D6841—08

Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber

2303.2.5.2

D6878/D6878M—13

Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing

1507.13.2

D6947/D6947M—07(2013)E1

Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System

Table 1507.14.3, 1507.15.2

D7032—14

Standard Specification for Establishing Performance Ratings for Wood, Plastic Composite Deck Boards and Guardrail Systems (Guards or Rails)

2612.2, 2612.4, 2612.5.1

D7147—11

Specification for Testing and Establishing Allowable Loads of Joist Hangers

2303.5.1, 2303.5.2, 2304.10.3

D7158/D7158M—19ae1

Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method)

1504.1.1, 1507.1.1, 1507.2.7.1

D7254—17

Standard Specification for Polypropylene (PP) Siding

1404.12

D7655/D7655M—12

Standard Classification for Size of Aggregate Used as Ballast for Roof Membrane Systems

1507.12.3, 1507.13.3

D7672—14

Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies

2303.1.13

E90—09

Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

1207.2, 1207.2.1

E96/E96M—2015

Test Method for Water Vapor Transmission of Materials

202, 449.3.6.4.2, 451.3.6.3.3, 1523.6.5.2.17.7, B302.1

E108—16

Standard Test Methods for Fire Tests of Roof Coverings

453.12.1, 1505.1, 1513.1, 1516.1, 2603.6, 2610.2, 2610.3

E119—2016

Standard Test Methods for Fire Tests of Building Construction and Materials

703.2, 703.2.1, 703.2.3, 703.2.5, 703.3, 703.4, 703.6, 704.12, 705.7, 705.8.5, 707.6, 712.1.13.2, 714.4.1, 715.1, 715.4, 716.2, Table 716.3, Table 716.5, 716.5.6, 716.5.8.1.1, Table 716.6, 716.6.7.1, 717.3.1, 717.5.2, 717.5.3, 717.6.1, Table 721.1(1), 2103.1, 2603.5.1

E136—16

Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C

703.5.1

E283—04(2012)

Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows Curtain Walls, and Doors Under Specified Pressure Difference Across the Specimen

202

E330/E330M—02 or 14

Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference

1709.5.2, 1709.5.2.1, 1709.8, 2415.4, 2415.7.1

E331—00 (2009)

Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference

1403.2, 2415.4

E492—09

Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling Assemblies Using the Tapping Machine

1207.3

E648—14c

Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat Energy Source

406.8.3, 424.2, 804.2, 804.3

E648—17

Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat Energy Source

406.1.4, 424.2, 804

E681—2009(2015)

Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases

202

E736/E736M—00 (2015)E1

Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to Structural Members

704.13.3.2

E814—2013A

Standard Test Method of Fire Tests of Through-penetration Firestops

202, 714.4.1.2

E970—2014

Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source

720.3.1

E1300—04e01, 07e01, 09e, 12AE1 or 16

Practice for Determining Load Resistance of Glass in Buildings

1709.5.1, 2404.1, 2404.2, 2404.3.1, 2404.3.2, 2404.3.3, 2404.3.4, 2404.3.5, 2411.2.1.1, 2411.2.1.2, 2411.3.1.2

E1347

Standard Test Method for Color and Color-Difference Measurement by Tristimulus Colorimetry

454.1.2.4, 454.1.11.3

E1354—2016

Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter

424.2, 1403.5

E1477

Standard Test Method for Luminous Reflectance Factor of Acoustical Materials by Use of Integrating-Sphere Reflectometers

454.1.2.4

E1592—05(2012)

Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

1504.3.2

E1602—03(2010)E1

Guide for Construction of Solid Fuel-burning Masonry Heaters

2112.2

E1886—12 or 2013a

Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Impact Protective Systems Impacted by Missiles and Exposed to Cyclic Pressure Differentials

1609.1.2, 1709.5.1

E1966—2015

Standard Test Method for Fire-resistant Joint Systems

202, 715.3

E1996—17 or 2012a or 2014a

Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes

449.4.2.5.1, 450.4.2.5.1, 1609.1.2, 1609.1.2.2, 1709.5.1

E2072—14

Standard Specification for Photoluminescent (Phosphorescent) Safety Markings

1025.3, 1025.4

E2140—01

Standard Test Method for Water Penetration of Metal Roof Panel Systems by Static Water Pressure Head

Table 1515.2, 1523.6.5.2.4.1.1, TAS 110

E2178—13

Standard Test Method for Air Permeance of Building Materials

202, 1507.10.2

E2203—02

Dense Thermoplastic Elastomers Used for Compression Seals, Gaskets, Setting Blocks, Spacers and Accessories

2411.3.4

E2273—03(2011)

Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies

1408.4.1

E2307—15B

Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using the Intermediate-scale, Multistory Test Apparatus

715.4

E2322—03 (Reapproved 2015)

Standard Test Method for Conducting Transverse and Concentrated Load Tests on Panels Used in Floor and Roof Construction

3115.4.2

E2353—14

Standard Test Methods for Performance of Glazing in Permanent Railing Systems, Guards and Balustrades

2407.1.2

E2397/E2397M—2015

Standard Practice for Determination of Dead Loads and Live Loads Associated with Vegetative Green Roof Systems

1607.12.3.1

E2404—15a

Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics

803.1.4

E2556/E2556M—10

Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment

2510.6

E2568—09e1

Standard Specification for PB Exterior Insulation and Finish Systems

1408.2

E2570/E2570—07(2014)E1

Standard Test Method for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) for EIFS with Drainage

1408.4.1.1

E2573—12

Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics

803.10

E2599—15

Standard Practice for Specimen Preparation and Mounting of Reflective Insulation Materials and Vinyl Stretch Ceiling Materials for Building Applications to Assess Surface Burning Characteristics

2614.3

E2634—11(2015)

Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems

1903.4

E2751/E2751M—13

Standard Practice for Design and Performance of Supported Laminated Glass Walkways

2409.1

F547—(2012)

Terminology of Nails for Use with Wood and Wood-based Materials

Table 2506.2

F1346—91 (2010)

Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs

454.1.1, 454.1.3.1.9, 454.2.2, 454.2.17

F1487

Standard Consumer Safety Performance Specification for Playground Equipment for Public Use

453.4.5, 453.10.5.2

F1667—15

Specification for Driven Fasteners: Nails, Spikes and Staples

Table 721.1(2), Table 721.1(3), 1506.5, 1507.2.6, 2303.6, Table 2506.2

F2006—10 or 17

Standard/Safety Specification for Window Fall Prevention Devices for Nonemergency Escape (Egress) and Rescue (Ingress) Windows

1015.8

F2090—17

Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms

1015.8, 1015.8.1

F2200—2014

Standard Specification for Automated Vehicular Gate Construction

3110.3

F2208—2014

Standard Safety Specification for Residential Pool Alarms

454.2.17.1.9

F2376—17a

Standard Practice for Classification, Design, Manufacture, Construction, and Operation of Water Slide Systems

454.1.9.2.1.1

F3125/F3125M—15

Standard Specification for High Strength Structural Bolts, Steel and Alloy Steel, Heat Treated, 120 ksi (830 MPa) and 150 ksi (1040 MPa) Minimum Tensile Strength, Inch and Metric Dimensions

2214.3

G53—96

Practice for Operating Light-and Water-Exposure Apparatus (Fluorescent UV-Condensation Type) for Exposure of Nonmetallic Materials


G60—01

Standard Practice for Conducting Cyclic Humidity Tests

2319.17.2.2.8, 2603.12.2

G85

Standard Practice for Modified Salt Spray (Fog) Testing

1517.5.1, 1517.5.2, 1523.6.5.2.10, 1523.6.5.2.11

G152—13

Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials

1504.6

G153

Standard Practice for Operating Enclosed Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials

1504.6

G154—12A

Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials

1504.6

G155—13

Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials

1504.6, 2615.2

AWC

American Wood Council
222 Catoctin SE, Suite 201
Leesburg VA 20175

AWC WCD No. 4—2003

Wood Construction Data—Plank and Beam Framing for Residential Buildings

2306.1.2, 2314.4.7

ANSI/AWC WFCM—2018

Wood Frame Construction Manual for One- and Two-Family Dwellings

1609.1.1, 1609.1.1.1, 2301.2, 2309.1, 2314.4.7

ANSI/AWC NDS—2018

National Design Specification (NDS) for Wood Construction with 2015 NDS Supplement

202, 722.1, Table 1604.3, 1809.12, 1810.3.2.4, Table 1810.3.2.6, 1905.1.8, 2304.13, 2306.1, Table 2306.2(1), Table 2306.2(2), Table 2306.3(1), Table 2306.3(2), 2307.1, 2314.4.7

AWC STJR—2015

Span Tables for Joists and Rafters

2306.1.1, 2314.4.7

ANSI/AWC PWF—2015

Permanent Wood Foundation Design Specification

1805.2, 1807.1.4, 2304.10.5.2, 2314.4.7

ANSI/AWC SDPWS—2015

Special Design Provisions for Wind and Seismic

202, 2305.1, 2305.2, 2305.3, 2306.1, 2306.2, 2306.3, Table 2306.3(1), Table 2306.3(3), 2307.1, 2314.4.7

AWPA

American Wood Protection Association
P.O. Box 361784
Birmingham AL 35236-1784

C1—03

All Timber Products-Preservative Treatment by Pressure Processes

1505.6

M4—2015

Standard for the Care of Preservative-treated Wood Products

1810.3.2.4.1, 2303.1.9, 2314.4.5

U1—16

USE CATEGORY SYSTEM: User Specification for Treated Wood Except Commodity Specification H

1403.6, Table 1507.9.6, 1807.1.4, 1807.3.1, 1809.12, 1810.3.2.4.1, 2303.1.9, 2304.12.1, 2304.12.4, 2304.12.3, 2304.12.5, 2314.4.5

AWS

American Welding Society
8669 NW 36 Street, #130
Doral FL 33166

B2.1—B2.1M—2018

Specification for Welding Procedure and Performance Qualification

2214.3

D1.1—D1.1M—2020

Structural Welding Code—Steel

2214.3

D1.2

Structural Welding Code—Aluminum

2003.3

D1.3—D1.3M—2018

Structural Welding Code—Sheet Steel

2214.3

D1.4—D1.4M—2017

Structural Welding Code—Reinforcing Steel

2214.3

D9.1—D9.1M—2018

Sheet Metal Welding Code

2214.3

BHMA

Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York NY 10017-6603

A156.10—2011

Power Operated Pedestrian Doors

1010.1.4.2

A156.19—2013

Standard for Power Assist and Low Energy Operated Doors

1010.1.4.2

A156.27—11

Power and Manual Operated Revolving Pedestrian Doors

1010.1.4.1

A156.38—2014

Low Energy Power Operated Sliding and Folding Doors

1010.1.4.2

CEN

European Committee for Standardization (CEN) B-10 50 Brussels
Central Secretariat
Rue de Stassart 36

EN 1081—98

Resilient Floor Coverings—Determination of the Electrical Resistance

406.7.1

BS EN 15250—2007

Slow Heat Release Appliances Fired By Solid Fuel Requirements and Test Methods

2112.2, 2112.5

CGSB

Canadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec Canada KIA 1G6

37-GP-52M (1984)

Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric

1504.7, 1507.12.2

37-GP-56M (1980)

Membrane, Modified, Bituminous, Prefabricated and Reinforced for Roofing—with December 1985 Amendment

1507.11.2

CISCA

Ceilings and Interior Systems Construction Association
1010 Jorie Blvd., Suite 30
Oak Brook IL 60523

CISCA—2007

Recommended Test Procedures for Access Floors

3115.4.2, 3115.4.3

CPA

Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg VA 20176

ANSI A135.4—2012

Basic Hardboard

1404.3.1, 2303.1.7, 2314.4.1

ANSI A135.5—2012

Prefinished Hardboard Paneling

2303.1.7, 2304.7

ANSI A135.6—2012

Engineered Wood Siding

1404.3.2, 2303.1.7, 2314.4.1

A208.1—2016

Particleboard

2303.1 8, 2303.1. 8.1

CPSC

Consumer Product Safety Commission
4330 East West Highway
Bethesda MD 20814-4408

16 CFR Part 1201 (2002)

Safety Standard for Architectural Glazing Material

2406.2, Table 2406.2(1), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.2, 2409.4.1

16 CFR Part 1209 (2002)

Interim Safety Standard for Cellulose Insulation

720.6

16 CFR Part 1404 (2002)

Cellulose Insulation

720.6

16 CFR Part 1500 (2009)

Hazardous Substances and Articles; Administration and Enforcement Regulations

202

16 CFR Part 1500.44(2009)

Method for Determining Extremely Flammable and Flammable Solids

202

16 CFR Part 1507 (2002)

Fireworks Devices

202

16 CFR Part 1630 (2007)

Standard for the Surface Flammability of Carpets and Rugs

804.4.1, 804.4.2

Pub. No. 362

Safety Barrier Guidelines for Home Pools

454.1.3.1.9

CSA

Canadian Standards Association
8501 East Pleasant Valley
Cleveland OH 44131-5516

AAMA/WDMA/CSA 101/I.S.2/A440—08, 11 or 17

Specifications for Windows, Doors and Unit Skylights

1010.1.7, 1709.5.1, 2405.5, 2411.3.2.1

CSSB

Cedar Shake and Shingle Bureau
P. O. Box 1178
Sumas WA 98295-1178

CSSB—97

Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau

Table 1507.8.5, Table 1507.9.6


New Roof Construction Manual (2015)

1507.8

DASMA

Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland OH 44115-2851

ANSI/DASMA 107—2017

Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation

2603.4.1.9

108—05, 12 or 17

Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference

1709.5.2.1

115—05, 12 or 17

Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure

1609.1.2

DECO

Document Engineering Co., Inc.
5210 Stagg Street
Van Nuys CA 91405

ANSI Z358.1—04

Emergency Eyewash and Shower Equipment

450.3.11.7

DOC/NIST

U.S. Department of Commerce
National Institute of Standards and Technology
100 Bureau Drive Stop 3460
Gaithersburg MD 20899

CS236

Mat-Formed Particleboard

2314.4.6

PS-2—10

Performance Standard for Wood-based Structural-use Panels

2303.1.5, 2304.7, 2304.8(5), Table 2306.2(1), Table 2306.2(2), 2314.4.6

PS 20—05

American Softwood Lumber Standard

202, 1810.3.2.4, 2303.1.1, 2314.4.6

PS 56

Structural Glued Laminated Timber

2314.4.6

DOL/OSHA

U.S. Department of Labor
Occupational Safety and Health Administration
Frances Perkins Building
200 Constitution Avenue NW
Washington DC 20210

29 CFR Part 1910.1000 (2015)

Air Contaminants

202

29 CFR 1910.1200

OSHA Hazard Communication Standard

202, 453.6.2

DOTn

U.S. Department of Transportation
c/o Superintendent of Documents
1200 New Jersey Avenue, SE
Washington DC 20402-9325

14 CFR Part 150 (2005)

The Aviation Safety and Noise Abatement Act of 1979

3114.1

49 CFR Parts 100—185—2015

Hazardous Materials Regulations

202

49 CFR Part 172—2015

Hazardous Materials Tables, Special Provisions, Hazardous Materials Communications, Emergency Response Information and Training Requirements

202

49 CFR Parts 173.137 (2009)

Shippers—General Requirements for Shipments and Packaging—Class 8—Assignment of Packing Group

202

49 CFR—Parts 173—178—(2015)

Specification of Transportation of Explosive and Other Dangerous Articles, UN 0335, UN 0336 Shipping Containers

202

FDOE

Florida Office of Educational Facilities
1014 Turlington Building
325 West Gaines Street
Tallahassee FL 32399-0400

SREF

Size of Space and Occupant Design Criteria

453.4.1, 453.8.2

SREF

Life Cycle Cost Guidelines for Materials and Building Systems for Florida's Public Educational Facilities

453.8.7

FEMA

Federal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington DC 20472

FEMA-TB-11—01

Crawlspace Construction for Buildings Located in Special Flood Hazard Areas

1805.1.2.1

FGI

The Facility Guidelines Institute
9750 Fall Ridge Trail
St. Louis MO 63127

GHCF—18

Guidelines for Design and Construction of Hospitals

449.2.2, 449.3.2, 449.3.3, 449.3.4, 449.3.5, 449.3.6, 449.3.7, 449.3.9, 449.3.11, 449.3.13, 469.2.1.2

GHCF—18

Guidelines for Design and Construction of Outpatient Facilities

451.2.2, 451.3.3, 451.3.3.1, 451.3.4, 451.3.5, 451.3.6, 451.3.8, 451.3.10, 451.3.13, 469.2.1.2

GHCF—18

Guidelines for Design and Construction of Residential Health, Care, and Support Facilities (First Printing 2018)

450.2.2, 450.3.2, 450.3.3.1, 450.3.3.2, 450.3.3.3, 450.3.3.4, 450.3.3.5, 450.3.3.6, 450.3.4, 450.3.4.3, 450.3.4.4, 450.3.5, 450.3.6, 450.3.7, 450.3.8, 450.3.9, 450.3.11, 450.3.14, 450.3.15

FINA

Federation Internationale de Natation Amateur
Av. de l' Avant-Poste 4
1005 Lausanne
SWITZERLAND

CHG-22

FINA Handbook 1998—2000

454.1.2.2.1


FINA Handbook 2005—2009

454.1.2.7

Florida Codes

Florida Building Commission
Building Codes and Standards Office
Department of Business and Professional Regulation
2601 Blair Stone Road
Tallahassee FL 32399

FBC-EC—Seventh Edition (2020)

Energy Conservation

101.4.6, 201.3, 202, 1203.1, Table 1203.3, 1203.4.2, 1301.1.1, 1405.3.1

FBC-FG—Seventh Edition (2020)

Fuel Gas

101.4.1, 201.3, 406.1.9, 415.9.2, 454.2.1.2, 454.2.15, 455.3.7, 456.3.6.1, 456.3.6.2, 2113.11.1.2, 2113.15, 2702.2.5, 2801.1, B201, E201

FBC-R—Seventh Edition (2020)

Residential

101.2, 102.6.1, 105.15, 117.1, 305.2.3, 308.3.4, 308.4.2, 308.6.4, 310, 310.5.1, 310.5.2, 310.6, 1907.2, K111.1

FFPC—Seventh Edition (2020)

Florida Fire Prevention Code

101.4.5, 102.6, 102.6.2, 201.3, 202, 307.1, Table 307.1(1), Table 307.1(2), 307.1.1, 403.4.5, 404.2, 406.7, 406.8, 407.2.5, 407.4, 410.3.6, 411.1, 412, 412.6.1, 413, 414.1.1, 414.1.2, 414.1.2.1, 414.2, 414.2.5, Table 414.2.5(1), Table 414.2.5(2), 414.3, 414.5, 414.5.1, Table 414.5.1, 414.5.2, 414.5.3, 414.6, 415, 415.6, 415.6.1, 415.6.1.1, 415.6.1.4, Table 415.6.2, 415.8.2, 415.9, 415.9.1, 415.9.1.3, 415.9.1.4, 415.9.1.6, 415.9.1.7, 415.9.1.8, 415.9.2, 415.9.3, 415.10, 415.11, 415.11.1.7, 415.11.4, 415.11.7.2, 415.11.9.3, 415.11.10.1, 416, 416.4, 422.3.1, 422.3.2, 426.1, 426.1.4, 451.2.1, 453.1, 453.2.1, 453.3.2, 453.3.3, 453.3.5, 453.3.6, 453.4, 453.5.1, 453.5.13, 453.6.1, 453.7.7.1, 453.8.1, 453.8.1.3, 453.8.4, 453.8.5, 453.9.1, 453.10.6, 453.12.2, 453.13.1, 453.14.2, 453.14.2.1, 453.20.4, 453.21.1, 453.22.1, 453.26.1, 453.27.1, 453.27.9.1, 453.27.10.1, 453.27.15.3, 454.2.1.2, 455.4.3, 456.3.4, 457.1.3.1.1, 457.1.4.1.1, 457.1.4.2.13, 457.1.4.13.2, 457.2.2.1.1, 459.2, 459.2.3, 463.4, 467.3.1, 467.9.1, Table 504.3a, Table 504.4a,b, Table 506.2a,b, 507.4, 507.8.1.1.1, 507.8.1.1.2, 507.8.1.1.3, Table 509, 705.8.1, 707.1, 901.2, 901.3, 901.5, 901.6.2, 901.6.3, 903.2.7.1, 903.2.11.3.1, Table 903.2.11.6, 903.2.12, 903.3.1.2.2, 903.3.1.2.3, 903.5, 904.2.2, 904.11.3, 905.1, 905.3.6, 905.3.7, 906.1, 906.4, 907.1.1, 907.2.5, 907.2.6, 907.2.13.2, 907.2.15, 907.2.16, 907.2.23, 907.2.24, 907.5.2.2, 907.6.6, 907.6.6.2, 907.8, 909.6.3, 909.12.1, 909.19, 909.20, 910.2.2, 910.5, 912.4.3, 916.2, 916.7, 916.10, 916.11, 917.1, 1001.3, 1001.4, 1203.5.2, 1203.6, 1507.16, 1507.18, Table 1604.5, 2603.4.1.12, 2701.1, 2702.1.3, 2702.2.3, 2702.2.7, 2702.2.10, 2702.2.13, 2702.2.14, 2702.4, 3003.3, 3007.9.1, 3008.1.3, 3102.1, 3103.1, 3111.2, 3111.3, 3111.3.4, 3111.3.5, 3302.3, 3303.7, 3309.2, 3601.2, B201, E201

61C-5

Rule 61C, Florida Administrative Code (Bureau of Elevator Safety Regulations)

3001.1

64E

Rule 64E, Florida Administrative Code (Sewage Disposal)

454.1.1, 454.1.2.1, 454.1.10.3, 457.1.3.2.12, 457.1.4.13.2, 457.1.4.13.6, 457.2.3, 465.1, 465.4.7, 465.5.1, 465.13.1.1, 2901.1

FBC-TPHVHZ—

Florida Building Code, Test Protocols for High Velocity Hurricane Zones



RAS 113

1518.8.1.1


RAS 128

1525


RAS 133

1518.9.2


RAS 150

1519.1, 1525


TAS 112

1523.6.5.2


TAS 126

1521.12


TAS 301

1515.1.3

FM

Factory Mutual Global Research
Standards Laboratories Department
1151 Boston-Providence Turnpike
Norwood MA 02062

4430 (2012)

Approval Standard for Heat and Smoke Vents

910.3.1

4470—2016

Approval Standard for Single-Ply Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR) And Liquid Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction

1504.7, 1515.1.1, 1515.2.4

4471 (1992)

Approval Standard for Class I Panel Roofs

1515.1.1, Table 1515.2, 1523.6.5.2.4.1

4474 (2011)

American National Standard for Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures

1504.3.1, 1504.3.3

4880—2015

Approval Standard for Class 1 Rating of Building Panels or Interior Finish Materials

2603.9

FRSA

Florida Roofing Sheet Metal and Air Conditioning Contractors Association
P.O. Box 4850
Winter Park FL 32793

FRSA/TRI September 2018(09—18)

Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition Revised

1507.3.2, 1507.3.3, 1507.3.3.1, 1507.3.7, 1507.3.8, 1507.3.9

FS

Federal Specification
941 Jefferson Davis Highway, Suite 104
Arlington VA 22202

TTC 555B

Test Specification for Wind Driven Rain Infiltration Resistance

1523.6.2.1.1, 1523.6.3.1

GA

Gypsum Association
6525 Belcrest Road, Suite 480
Hyattsville MD 20782

GA 216—2016

Application and Finishing of Gypsum Panel Products

Table 2508.1, 2509.2

GA 600—2015

Fire-Resistance Design Manual, 21st Edition

Table 721.1(1), Table 721.1(2), Table 721.1(3)

GSA

General Services Administration
1800 F Street, NW
Washington DC 20405

DD-G-451c (1977)

Standard for Glass, Flat and Corrugated, for Glazing Mirrors and Other Uses

2411.1.2

HPVA

Hardwood Plywood Veneer Association
1825 Michael Faraday Drive
Reston VA 20190

ANSI/HPVA HP-1—2016

American National Standard for Hardwood and Decorative Plywood

2303.3, 2304.7

ICC

International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington DC 20001

ICC A117.1—09

Accessible and Usable Buildings and Facilities

202, 907.5.2.3.3, 1009.9, 1009.11, 1010.1.9.7, 1012.1, 1012.6.5, 1012.10, 1013.4, 1023.9, 1101.2

ICC 400—17

Standard on Design and Construction of Log Structures

2301.2

ICC 500—14

ICC/NSSA Standard on the Design and Construction of Storm Shelters

202, 423.1, 423.1.1, 423.2, 423.3, 423.4, 453.9.1, 453.10.6, 453.25.4, 1604.5.1

ICC 600—14

Standard for Residential Construction in High-wind Regions

1609.1.1, 1609.1.1.1

SBCCI SSTD 11—97

Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles

1504.2.1.1, 1504.2.1.2

IEEE

Institute of Electrical and Electronics Engineers
2001 L Street, NW, Suite 700
Washington DC 20036-4910

IEEE

Appropriate standards for the type of equipment being protected

457.1.4.1.5, 449.3.15.5, 450.3.19.4

IESNA

Illuminating Engineering Society of North America
120 Wall Street, 17th Floor
New York NY 10005-4001

ANSI/IESNA RP-28-07

Lighting and the Visual Environment for Senior Living

450.3.15.3

ANSI/IESNA TM-15-11 Addendum A

Backlight, Uplight, and Glare (BUG) Ratings

Table 453.10.3.7(2)

ISO

International Organization for Standardization
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case Postale 56
CH-1211 Geneva 20 Switzerland

ISO 8115—86

Cotton Bales—Dimensions and Density

Table 307.1(1), Table 415.11.1.1.1

ISO 8336—09

Fiber-Cement Flat Sheets - Product Specification and Test Methods

1404.10, 1405.16.1, 1405.16.2, Table 2509.2

MHI

Material Handling Institute
8720 Red Oak Blvd. Suite 201
Charlotte NC 28217

ANSI MH29.1—08

Safety Requirements for Industrial Scissors Lifts

Table 3001.2

MIA

Marble Institute of America
28901 Clemens Road, Suite 100
Cleveland OH 44145

MIA (1998)

Appropriate standards for marble selection, cutting and design

460.6.4, 460.7.1.3, 460.9.2

NAAMM

National Association of Architectural Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312
Glen Ellyn IL 60137

FP 1001—17

Guide Specifications for Design of Metal Flag Poles

1609.1.1

NAAMM MBG 531—2017

Metal Grating Manual

2214.3

NCMA

National Concrete Masonry Association
13750 Sunrise Valley
Herndon VA 22071-4662

TEK 5—84 (1996)

Details for Concrete Masonry Fire Walls

Table 721.1(2)

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471

10—18

Standard for Portable Fire Extinguishers

453.15.3, 906.2, 906.3.2, 906.3.4, Table 906.3(1), Table 906.3(2)

11—16

Standard for Low Expansion Foam

904.7

12A—15

Standard on Halon 1301 Fire Extinguishing Systems

904.9

13—16

Installation of Sprinkler Systems

461.1, 712.1.3.1, 903.3.1.1, 903.3.2, 903.3.8.2, 903.3.8.5, 904.12, 905.3.4, 907.6.4, 1019.3

13D—16

Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes

903.2.11.3, 903.3.1.3

13R—16

Standard for the Installation of Sprinkler Systems in Low Rise Residential Occupancies

903.2.11.3, 903.3.1.2, 903.3.5.2, 903.4

14—16

Standard for the Installation of Standpipe and Hose System

905.2, 905.3.4, 905.4.2, 905.6.2, 905.8, 3002.10

16—15

Standard for the Installation of Foam-water Sprinkler and Foam-water Spray Systems

904.7, 904.12

17—17

Standard for Dry Chemical Extinguishing Systems

904.6, 904.12

20—16

Standard for the Installation of Stationary Pumps for Fire Protection

412.3.4.1, 449.3.10, 450.3.13.1, 451.3.9.1, 904.10, 913.1, 913.2.1, 913.5

30A—18

Code for Motor Fuel-Dispensing Facilities and Repair Garages

406.1.9.2

31—15

Standard for the Installation of Oil-burning Equipment

2113.15

32—16

Standard for Dry Cleaning Plants

415.9.3

40—16

Standard for the Storage and Handling of Cellulose Nitrate Film

409.1

58—17

Liquefied Petroleum Gas Code

415.9.2

61—17

Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities

426.1

74—89

Standards for the Installation, Maintenance and Use of Household Fire Warning Equipment

461.1

80—16

Standard for Fire Doors and Other Opening Protectives

410.3.5, 509.4.2, 716.1, 716.5.7, 716.5.8.1, 716.5.9.2, 716.6.4, 717.4.1.2, 1010.1.4.3

82—14

Standard on Incinerators and Waste and Linen Handling Systems and Equipment

713.13

85—15

Boiler and Combustion System Hazards Code

426.1

91—04

Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Noncombustible Particulate Solids

468.3.6.5

92—15

Standard for Smoke Control Systems

909.7, 909.8

96—2017

Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations

466.6.2

105—16

Standard for Smoke Door Assemblies and Other Opening Protectives

405.4.2, 710.5.2.2, 716.5.3.1, 717.4.1.2, 909.20.4.1, 2702.1.3

111—16

Standard on Stored Electrical Energy Emergency and Standby Power Systems

469.4.14.9.2, 2702.1.3

120—15

Standard for Fire Prevention and Control in Coal Mines

426.1

170—18

Standard for Fire Safety and Emergency Symbols

1025.2.6.1

211—16

Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances

2112.5

221—18

Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls

706.2

252—17

Standard Methods of Fire Tests of Door Assemblies

Table 716.3, 716.3.1, 716.4, 716.5.1, 716.5.3, 716.5.4, 716.5.5.1, 716.5.8.1.1

253—15

Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source

406.1.4, 406.8.3, 424.2, 804.2, 804.3

257—17

Standard for Fire Test for Window and Glass Block Assemblies

Table 716.3, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.7.3

259—18

Standard Test Method for Potential Heat of Building Materials

2603.4.1.10, 2603.5.3

265—2015

Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings on Full Height Panels and Walls

803.1.3, 803.1.3.1

268—2017

Standard Test Method for Determining Ignitability of Exterior Wall Assemblies Using a Radiant Heat Energy Source

1406.2.1.1, 1406.2.1.1.1, 1406.2.1.1.2, 2603.5.7, D105.1, D106

275—17

Standard Method of Fire Tests for the Evaluation of Thermal Barriers

1407.10.2, 1409.10.2, 2603.4

276—15

Standard Method of Fire Tests for Determining the Heat Release Rate of Roofing Assemblies With Combustible Above-Deck Roofing Components

1508.1, 2603.3, 2603.4.1.5

285—12

Standard Fire Test Method for the Evaluation of Fire Propagation Characteristics of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components

718.2.6, 1403.5, 1407.10.4, 1409.10.4, 1510.6.2, 2603.5.5

286—15

Standard Methods of Fire Test for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth

402.6.4.4, 803.1.2, 803.1.2.1, 803.11, 1407.10.3, 2603.7, 2603.9, 2604.2.4, 2614.4

288—17

Standard Methods of Fire Tests of Horizontal Fire Door Assemblies Installed in Horizontal in Fire-resistance-rated Floor Systems

712.1.13.1

289—13

Standard Method of Fire Test for Individual Fuel Packages

402.6.2, 402.6.4.5, 424.2, 806.4

409—16

Standard for Aircraft Hangars

412.4.6, Table 412.4.6, 412.4.6.1, 412.6.5

418—16

Standard for Heliports

412.8.4

484—18

Standard for Combustible Metals

426.1

654—17

Standard for the Prevention of Fire & Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids

426.1

655—17

Standard for the Prevention of Sulfur Fires and Explosions

426.1

664—17

Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities

426.1

701—15

Standard Method of Fire Tests for Flame-Propagation of Textiles and Films

410.3.6, 424.2, 801.4, 806.1, 806.3, 806.4, 3102.3, 3102.3.1, 3102.6.1.1, 3105.3.4.1, 3105.4, 3105.6, D102.2.8, D106, H106.1.1, H115

704—17

Standard System for the Identification of the Hazards of Materials for Emergency Response

202, 415.5.2

750—15

Standard on Water Mist Fire Protection Systems

202, 904.11.1.1

780—17

Standard for the Installation of Lightning Protection Systems

449.3.15.1, 450.3.19.1, 453.17.7

1124—17

Code for the Manufacture, Transportation and Storage of Fireworks and Pyrotechnic Articles

415.6.1.1

2001—15

Standard on Clean Agent Fire Extinguishing Systems

904.10

NSF

NSF International
P.O. Box 130140
789 N. Dixboro Road
Ann Arbor MI 48113-0140, USA

NSF 50—11

Equipment for Pools, Spas, Hot Tubs, and Other Recreational Water Facilities

454.1.1, 454.1.2.1, 454.1.6.5.1, 454.1.6.5.16, 454.1.6.5.16.4.2, 454.1.6.5.16.5.2, 454.1.9.2.5.2, 454.1.9.8.6.1, 454.1.10.3, 454.1.11.9

NSF 60—05

Drinking Water Treatment Chemicals—Health Effects

454.1.2.1, 454.1.6.5.18

PCI

Precast Prestressed Concrete Institute
200 West Adams Street, Suite 2100
Chicago IL 60606-6938

MNL 124—11

Design for Fire Resistance of Precast Prestressed Concrete

722.2.3.1

MNL 128—01

Recommended Practice for Glass Fiber Reinforced Concrete Panels

1903.3

PTI

Post-Tensioning Institute
38800 Country Club Drive
Farmington Hills MI 48331

PTI DC—10.5-12

Standard Requirements for Design and Analysis of Shallow Concrete Foundations on Expansive Soils

1808.6.2

RCSC

Research Council on Structural Connections
c/o Stanley D. Lindsey & Assoc. Ltd. 2244 Metro Center Blvd., Suite 208
Nashville TN 37228-1320

RCSC—14

Specification for Structural Joints Using High Strength Bolts

2214.3

RMI

Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte NC 28217

ANSI/MH16.1—12

Specification for Design, Testing and Utilization of Industrial Steel Storage Racks

2209.1

ANSI/MH16.3—16

Specification for the Design, Testing, and Utilization of Industrial Steel Cantilevered Storage Racks

2209.2

SBCA

Structural Building Components Association
6300 Enterprise Lane
Madison WI 53719

ANSI/FS 100-12

Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies

2603.10

SDI

Steel Deck Institute
P. O. Box 25
Fox River Grove IL 60021

ANSI/SDI NC—2017

Standard for Noncomposite Steel Floor Deck

2210.1.1.1, 2214.3

ANSI/SDI RD—2017

Standard for Steel Roof Deck

2210.1.1.2, 2214.3

DDM—04

Diaphragm Design Manual

2214.3, 2222.4

ANSI/SDI C—2017

Standard for Composite Steel Floor Deck Slabs

2210.1.1.3, 2214.3

SJI

Steel Joist Institute
234 W. Cheves Street
Florence SC 29501

SJI-100—15

Standard Specification for K-Series, LH-Series, and DLH-Series Open Web Steel Joists and for Joist Girders, 2015

1604.3.3, 2203.2, 2207.1

SJI-200—15

Standard Specification for Composite Steel Joists, CJ-series

1604.3.3, 2203.2, 2207.1

SJI—07

Structural Design of Steel Joist Roofs to Resist Ponding Loads, Technical Digest No. 3

2214.3

SJI—15

Vibration of Steel Joist-Concrete Slab Floors, Technical Digest No. 5

2214.3

SJI—12

Design of Steel Joist Roofs to Resist Uplift Loads, Technical Digest No. 6

2214.3

SJI—08

Welding of Open Web Steel Joist and Joist Girders, Technical Digest No. 8

2214.3

SJI—08

Handling and Erection of Steel Joists and Joist Girders, Technical Digest No. 9

2214.3

SJI—17

44th Edition Standard Specifications Load Tables and Weight Tables for Steel Joists and Joist Girders

2214.3

SJI—18

90 Years of Open Web Steel Joist Construction

2214.3

SJI-07

Design of Lateral Load Resisting Frames Using Steel Joists and Joist Girders, Technical Digest No. 11

2214.3

SPRI

Single-Ply Roofing Institute
411 Waverly Oaks Road, Suite 331B
Waltham MA 02452

ANSI/SPRI/FM4435-ES-1—11

Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems

1504.5

ANSI/SPRI RP-4—13

Wind Design Guide for Ballasted Single-ply Roofing Systems

1504.4

STI

Steel Tube Institute
2516 Waukegan Road, Suite 172
Glenview IL 60025

HSS Design Manual, Volume 1

Section Properties & Design Information, 2015

2214.3

HSS Design Manual, Volume 2

Member Design, 2016

2214.3

HSS Design Manual, Volume 3

Connections at HSS Members, 2016

2214.3

HSS Design Manual, Volume 4

Truss & Bracing Connections, 2017

2214.3

TECO

Timber Company, Inc.
2402 Daniels Street
Madison WI 53704

TECO PRP-133

Performance Standards and Policies for Structural Use Panels

2314.4.8

TIA

Telecommunications Industry Association
1320 N. Courthouse Road
Arlington VA 22201-3834

222-H—2017

Structural Standards for Antenna Supporting Structures and Antennas and Small Wind Turbine Support Structures

1609.1.1, 3108.1, 3108.2

TMS

The Masonry Society
105 South Sunset Street, Suite Q
Longmont CO 80501

216—2013

Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies

Table 721.1(2), 722.1

302—2012

Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls

1207.2.1

403—2017

Direct Design Handbook for Masonry Structures

2101.2

TMS 404—16

Standard for the Design of Architectural Cast Stone

2101.2

TMS 504—16

Standard for the Fabrication of Architectural Cast Stone

2103.1

TMS 604—16

Standard for the Installation of Architectural Cast Stone

2104

TPI

Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria VA 22314

TPI 1—2014

National Design Standard for Metal-plate-connected Wood Truss Construction

2303.4.6, 2306.1, 2319.17.2.1.1, 2319.17.2.2.8

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062-2096

9—2009

Fire Tests of Window Assemblies—with Revisions through February 2015

Table 716.3, 716.3.2, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.7.3

10A—2009

Tin Clad Fire Doors—with Revisions through December 2013

716.5

10B—2008

Fire Tests of Door Assemblies—with Revisions through February 2015

716.3.1, Table 716.3, 716.5.2, 716.5.4, 716.5.5.1, 716.5.8.1.1

10C—2009

Positive Pressure Fire Tests of Door Assemblies—with Revisions through February 2015

Table 716.3, 716.3.1, 716.5.1, 716.5.3, 716.5.4, 716.5.5.1, 716.5.8.1.1, 1010.1.10.1

14B—2008

Sliding Hardware for Standard Horizontally mounted Tin Clad Fire Doors—with Revisions through May 2013

716.5

14C—06

Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs—with Revisions through May 2013

716.5

55A—04

Materials for Built-Up Roof Coverings

1507.10.2

103—2010

Factory-built Chimneys, for Residential Type and Building Heating Appliances—with Revisions through July 2012

718.2.5.1

127—2011

Factory-built Fireplaces—with Revisions through May 2015

718.2.5.1, 2111.12

181—05

Standard for Factory-Made Air Ducts and Air Connectors

449.3.6.4, 451.3.6.3, 451.3.6.3.4

199E—04

Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers

904.12.4.1

217—06

Single and Multiple Station Smoke Alarms—with Revisions through October 2015

907.2.11

263—11

Standard for Fire Tests of Building Construction and Materials—with Revisions through June 2015

703.2, 703.2.1, 703.2.3, 703.2.5, 703.3, 703.4, 703.6, 704.12, 705.7, 705.8.5, 707.6, 712.1.13, 714.4.1.1, 714.5.1, 715.1, 716.2, Table 716.3, 716.5.6, 716.5.8.1.1, Table 716.6, 717.3.1, 717.5.2, 717.5.3, 717.6.1, 717.6.2.1, Table 721.1(1), 2103.1, 2603.5.1

294—1999

Access Control System Units—with Revisions through February 2015

1010.1.9.7, 1010.1.9.8, 1010.1.9.9, 1010.1.9.10

300—05(R2010)

Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment—with Revisions through December 2014

904.12

300A—06

Outline of Investigation for Extinguishing System Units for Residential Range Top Cooking Surfaces

407.2.6, 904.13

305—2012

Panic Hardware—with Revisions through August 2014

1010.1.10.1

325—02

Door, Drapery, Gate, Louver and Window Operations and Systems— with Revisions through May 2015

406.1.1, 3110.4

555—2006

Fire Dampers—with Revisions through May 2014

717.3

555C—2006

Ceiling Dampers—with Revisions through December 2014

717.3

555S—99

Smoke Dampers—with Revisions through February 2014

717.3.1

580—2006

Test for Uplift Resistance of Roof Assemblies—with Revisions through October 2013

1504.3.1, 1504.3.2, 1504.3.3, 2222.4.6

641—2010

Type L Low-temperature Venting Systems—with Revisions through June 2013

2113.11.1.4

710B—2011

Recirculating Systems—with Revisions through August 2014

904.12

723—2008

Standard for Test for Surface Burning Characteristics of Building Materials—with Revisions through August 2013

202, 402.6.4.4, 406.7.2, 703.5.2, 720.1, 720.4, 803.1.1, 803.1.4, 803.10, 803.11, 806.7, 1403.5, 1404.12.1, 1407.9, 1407.10.1,1409.9, 1409.10.1, 1510.6.2, 1510.6.3, 2303.2, 2603.3, 2603.4.1.13, 2603.5.4, 2603.5.5, 2604.2.4, 2606.4, 2612.3, 2614.3, 3105.3.4.1, D102.2.8, D106

790—04

Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through July 2014

1505.1, 1513.1, 1516.1, 2603.6, 2610.2, 2610.3

793—08

Standards for Automatically Operated Roof Vents for Smoke and Heat—with Revisions through September 2011

910.3.1

864—03

Standards for Control Units and Accessories for Fire Alarm Systems— with Revisions through December 2014

909.12

924—06

Standard for Safety Emergency Lighting and Power Equipment—with Revisions through April 2014

1013.5

1040—96

Fire Test of Insulated Wall Construction—with Revisions through October 2012

1407.10.3, 1409.10.3, 2603.9

1069—07

Hospital Signaling and Nurse Call Equipment, 7th Edition

449.3.13.1, 450.3.17, 451.3.11.1, 467.8.3.6

1256—02

Fire Test of Roof Deck Construction—with Revisions through January 2007

1508.1, 2603.3, 2603.4.1.5

1479—03

Fire Tests of Through-penetration Firestops—with Revisions through June 2015

202, 714.4.1.2, 714.5.1.2, 714.5.4

1482—2011

Solid-Fuel-type Room Heaters—with Revisions through August 2015

2112.2, 2112.5

1703—02

Flat-Plate Photovoltaic Modules and Panels—with Revisions through October 2015

1505.8, 1505.9, 1507.17.6, 1510.7.4, 1518.11.1, 3111.3.1

1715—97

Fire Test of Interior Finish Material—with Revisions through January 2013

1407.10.3, 1409.10.2, 1409.10.3, 2603.4, 2603.9, 2614.4

1777—2007

Chimney Liners—with Revisions through October 2015

2113.11.1, 2113.19

1784—01

Air Leakage Tests of Door Assemblies—with Revisions through February 2015

405.4.3, 710.5.2.2, 710.5.2.2.1, 716.5.3.1, 716.5.7.1, 716.5.7.3, 3006.3, 3007.6.3, 3008.6.3

1897—12

Uplift Tests for Roof Covering Systems—with Revisions through September 2015

1504.3.1

1975—06

Fire Test of Foamed Plastics Used for Decorative Purposes

402.6.2, 402.6.4.5, 424.2

1994—04

Luminous Egress Path Marking Systems—with Revisions through May 2015

411.7, 1008.2.1, 1025.2.1, 1025.2.3, 1025.2.4, 1025.2.5

2017—2008

Standards for General-purpose Signaling Devices and Systems—with Revisions through May 2011

454.2.17.1.9

2034—2008

Standard for Single- and Multiple-Station Carbon Monoxide Alarm—with Revisions through March 2015

202

2075—2013

Standard for Gas and Vapor Detectors and Sensors

202

2079—04

Tests for Fire Resistance of Building Joint Systems—with Revisions through August 2015

202, 715.3, 715.6

2196—2001

Tests for Fire Resistive Cables—with Revisions through March 2012

909.20.6.1, 913.2.2, 2702.3, 3007.8.1, 3008.8.2

2200—2012

Stationary Engine Generator Assemblies—with Revisions through July 2015

2702.1.1

2202—09 (2012)

Standard for Electric Vehicle (EV) Charging System Equipment, 2013

406.1.7

2594—13

Standard for Electric Vehicle Supply Equipment, 2013

406.1.7

ULC

Underwriters Laboratories of Canada
7 Underwriters Road
Toronto, Ontario Canada M1R3B4

CAN/ULC S 102.2—2010

Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings and Miscellaneous Materials and Assemblies—with 2000 Revisions

720.2, 720.3, 720.4

USC

United States Code
c/o Superintendent of Documents U.S. Government Printing Office
732 North Capitol Street NW
Washington DC 20401

18 USC Part 1, Ch.40

Importation, Manufacture, Distribution and Storage of Explosive Materials

202

WCLIB

West Coast Lumber Inspection Bureau
P. O. Box 23145
Portland OR 97281

AITC 104—03

Typical Construction Details

2306.1

AITC 110—01

Standard Appearance Grades for Structural Glued Laminated Timber

2306.1

AITC 113—10

Standard for Dimensions of Structural Glued Laminated Timber

2306.1

AITC 117—10

Standard Specifications for Structural Glued Laminated Timber of Softwood Species

2306.1

AITC 119—96

Standard Specifications for Structural Glued Laminated Timber of Hardwood Species

2306.1

AITC 200—09

Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber

2306.1

WDMA

Window and Door Manufacturers Association
2025 M Street, NW Suite 800
Washington DC 20036-3309

AAMA/WDMA/CSA 101/I.S.2/A440—08 or 11 or 17

Specifications for Windows, Doors and Unit Skylights

1010.1.7, 1709.5.1, 2405.5, 2411.3.2

WRI

Wire Reinforcement Institute, Inc.
942 Main Street, Suite 300
Hartford CT 06103

WRI/CRSI—81

Design of Slab-on-ground Foundations—with 1996 Update

1808.6.2