Heads up: There are no amended sections in this chapter.

User note:

About this chapter: Chapter 6 lists the full title, edition year and address of the promulgator for all standards that are referenced in the code. The section numbers in which the standards are referenced are also listed.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 107.

AAMA

American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg IL60173-4268

AAMA/WDMA/CSA 101/I.S.2/A C440—17

North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights

Table C402.5.2

AHAM

Association of Home Appliance Manufacturers
1111 19th Street NW, Suite 402
Washington DC20036

ANSI/AHAM RAC-1—2008

Room Air Conditioners

Table C403.3.2(3)

AHAM HRF-1—2016

Energy, Performance and Capacity of Household Refrigerators, Refrigerator-Freezers and Freezers

Table C403.10.1

AHRI

Air-Conditioning, Heating, & Refrigeration Institute
2111 Wilson Blvd, Suite 500
Arlington VA22201

ISO/AHRI/ASHRAE 13256-1 (1998 RA2014)

Water-to-Air and Brine-to-Air Heat Pumps—Testing and Rating for Performance

Table C403.3.2(2)

ISO/AHRI/ASHRAE 13256-2 (1998 RA2014)

Water-to-Water and Brine-to-Water Heat Pumps —Testing and Rating for Performance

Table C403.3.2(2)

210/240—2016

Performance Rating of Unitary Air-conditioning and Air-source Heat Pump Equipment

Table C403.3.2(1), Table C403.3.2(2)

310/380—2014 (CSA-C744-04)

Standard for Packaged Terminal Air Conditioners and Heat Pumps

Table C403.3.2(3)

340/360—2015

Performance Rating of Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment

Table C403.3.2(1), Table C403.3.2(2)

365(I-P)—2009

Commercial and Industrial Unitary Air-conditioning Condensing Units

Table C403.3.2(1), Table C403.3.2(6)

390 (I-P)—2015

Performance Rating of Single Package Vertical Air-conditioners and Heat Pumps

Table C403.3.2(3)

400 (I-P)—2015

Performance Rating of Liquid to Liquid Heat Exchangers

Table C403.3.2(10)

440—2008

Performance Rating of Room Fan Coils—with Addendum 1

C403.11.3

460—2005

Performance Rating of Remote Mechanical-draft Air-cooled Refrigerant Condensers

Table C403.3.2(8)

550/590 (I-P)—2015

Performance Rating of Water-chilling and Heat Pump Water-heating Packages Using the Vapor Compression Cycle

C403.3.2.1, Table C403.3.2(7)

560—00

Absorption Water Chilling and Water Heating Packages

Table C403.3.2(7)

1160 (I-P) —2014

Performance Rating of Heat Pump Pool Heaters

Table C404.2

1200 (I-P)—2013

Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets

C403.10, Table C403.10.1(1), Table C403.10.1(2)

AMCA

Air Movement and Control Association International
30 West University Drive
Arlington Heights IL60004-1806

205—12

Energy Efficiency Classification for Fans

C403.8.3

220—08 (R2012)

Laboratory Methods of Testing Air Curtain Units for Aerodynamic Performance Rating

C402.5.6

500D—12

Laboratory Methods for Testing Dampers for Rating

C403.7.7

ANSI

American National Standards Institute
25 West 43rd Street, 4th Floor
New York NY10036

Z21.10.3/CSA 4.3—11

Gas Water Heaters, Volume III—Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous

Table C404.2

Z21.47/CSA 2.3—12

Gas-fired Central Furnaces

Table C403.3.2(4)

Z83.8/CSA 2.6—09

Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces

Table C403.3.2(4)

APSP

The Association of Pool & Spa Professionals
2111 Eisenhower Avenue, Suite 580
Alexandria VA22314

14—2014

American National Standard for Portable Electric Spa Energy Efficiency

C404.8

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329

ASHRAE 127-2007

Method of Testing for Rating Computer

Table C403.3.2(9)

ANSI/ASHRAE/ACCA Standard 183—2007 (RA2014)

Peak Cooling and Heating Load Calculations in Buildings, Except Low-rise Residential Buildings

C403.1.1

ASHRAE—2016

ASHRAE HVAC Systems and Equipment Handbook

C403.1.1

ISO/AHRI/ASHRAE 13256-1 (1998 RA2014)

Water-to-Air and Brine-to-Air Heat Pumps—Testing and Rating for Performance

Table C403.3.2(2)

ISO/AHRI/ASHRAE 13256-2 (1998 RA2014)

Water-to-Water and Brine-to-Water Heat Pumps—Testing and Rating for Performance

Table C403.3.2(2)

55—2013

Thermal Environmental Conditions for Human Occupancy

Table C407.5.1

90.1—2016

Energy Standard for Buildings Except Low-rise Residential Buildings

C401.2, Table C402.1.3, Table C402.1.4, C406.2, C502.1, C503.1, C504.1

140—2014

Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs

C407.6.1

146—2011

Testing and Rating Pool Heaters

Table C404.2

ASME

American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016-5990

ASME A17.1—2016/CSA B44—16

Safety Code for Elevators and Escalators

C405.8.2

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959

C90—14

Specification for Load-bearing Concrete Masonry Units

C1363—11

Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus

C303.1.4.1, Table C402.1.4, 402.2.7

C1371—15

Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers

Table C402.3

C1549—09(2014)

Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer

Table C402.3

D1003—13

Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics

C402.4.2.2

E283—04(2012)

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen

C402.5.1.2.2, Table C402.5.2, C402.5.7

E408—13

Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques

Table C402.3

E779—10

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

C402.5

E903—12

Standard Test Method Solar Absorptance, Reflectance and Transmittance of Materials Using Integrating Spheres (Withdrawn 2005)

Table C402.3

E1677—11

Specification for Air Barrier (AB) Material or Systems for Low-rise Framed Building Walls

C402.5.1.2.2

E1827—11

Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door

C402.5, C406.9

E1918—06(2015)

Standard Test Method for Measuring Solar Reflectance of Horizontal or Low-sloped Surfaces in the Field

Table C402.3

E1980—11

Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces

Table C402.3

E2178—13

Standard Test Method for Air Permanence of Building Materials

C402.5.1.2.1

E2357—11

Standard Test Method for Determining Air Leakage of Air Barriers Assemblies

C402.5.1.2.2

CRRC

Cool Roof Rating Council
449 15th Street, Suite 400
Oakland CA94612

ANSI/CRRC-S100—2016

Standard Test Methods for Determining Radiative Properties of Materials

Table C402.3, C402.3.1

CSA

CSA Group
8501 East Pleasant Valley Road
Cleveland OH44131-5516

AAMA/WDMA/CSA 101/I.S.2/A440—17

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

Table C402.5.2

CSA B55.1—2015

Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units

C404.8

CSA B55.2—2015

Drain Water Heat Recovery Units

C404.8

CTI

Cooling Technology Institute
P. O. Box 681807
Houston TX77268

ATC 105 (00)

Acceptance Test Code for Water Cooling Tower

Table C403.3.2(8)

ATC 105S—11

Acceptance Test Code for Closed Circuit Cooling Towers

Table C403.3.2(8)

ATC 106—11

Acceptance Test for Mechanical Draft Evaporative Vapor Condensers

Table C403.3.2(8)

STD 201—11

Standard for Certification of Water Cooling Towers Thermal Performances

Table C403.3.2(8)

CTI STD 201 RS(15)

Performance Rating of Evaporative Heat Rejection Equipment

Table C403.3.2(8)

DASMA

Door & Access Systems Manufacturers Association, International
1300 Sumner Avenue
Cleveland OH44115-2851

105—2016

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors

C303.1.3, Table C402.5.2

DOE

U.S. Department of Energy
c/o Superintendent of Documents
1000 Independence Avenue SW
Washington DC20585

10 CFR, Part 430—2015

Energy Conservation Program for Consumer Products: Test Procedures and Certification and Enforcement Requirement for Plumbing Products; and Certification and Enforcement Requirements for Residential Appliances; Final Rule

Table C403.3.2(4), Table C403.3.2(5), Table C404.2

10 CFR, Part 430, Subpart B, Appendix N—(2015)

Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers

C202

10 CFR, Part 431—2015

Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures and Efficiency Standards; Final Rules

Table C403.3.2(5), C405.6, Table C405.6, C405.7

10 CFR 431 Subpart B App B

Uniform Test Method for Measuring Nominal Full Load Efficiency of Electric Motors

C403.8.4, Table C405.7(1), Table C405.7(2), Table C405.7(3), C405.7(4)

NAECA 87—(88)

National Appliance Energy Conservation Act 1987 [Public Law 100-12 (with Amendments of 1988-P.L. 100-357)]

Table C403.3.2(1), Table C403.3.2(2), Table C403.3.2(4)

ICC

International Code Council, Inc.
500 New Jersey Avenue NW
6th Floor
Washington DC 20001

IBC—18

International Building Code®

C201.3, C303.2, C402.5.3, C501.4

IFC—18

International Fire Code®

C201.3, C501.4

IFGC—18

International Fuel Gas Code®

C201.3, C501.4

IPMC—18

International Property Maintenance Code®

C501.4

IPSDC—18

International Private Sewage Disposal Code®

C501.4

IEEE

Institute of Electrical and Electronic Engineers
3 Park Avenue, 17th Floor
New York NY10016

IEEE 515.1—2012

IEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Commercial Applications

C404.6.2

IES

Illuminating Engineering Society
120 Wall Street, 17th Floor
New York NY10005-4001

ANSI/ASHRAE/IESNA 90.1—2016

Energy Standard for Buildings, Except Low-rise Residential Buildings

C401.2, Table C402.1.3, Table C402.1.4, C406.2, C502.1, C503.1, C504.1

ISO

International Organization for Standardization
Chemin de Blandonnet 8, CP 401, 1214 Vernier
Geneva Switzerland

ISO/AHRI/ASHRAE 13256-1(1998 RA2014)

Water-to-Air and Brine-to-Air Heat Pumps -Testing and Rating for Performance

Table C403.3.2(2)

ISO/AHRI/ASHRAE 13256-2(1998 RA2014)

Water-to-Water and Brine-to-Water Heat Pumps -Testing and Rating for Performance

C403.3.2(2)

NEMA

National Electrical Manufacturers Association
1300 North 17th Street, Suite 900
Rosslyn VA22209

MG1—2014

Motors and Generators

C202

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471

70—17

National Electrical Code

C501.4

NFRC

National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt MD20770

100—2017

Procedure for Determining Fenestration Products U-factors

C303.1.3, C402.2.1.1

200—2017

Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence

C303.1.3, C402.4.1.1

400—2017

Procedure for Determining Fenestration Product Air Leakage

Table C402.5.2

SMACNA

Sheet Metal and Air Conditioning Contractors' National Association, Inc.
4021 Lafayette Center Drive
Chantilly VA20151-1219

SMACNA—2012

HVAC Air Duct Leakage Test Manual Second Edition

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062-2096

710—12

Exhaust Hoods for Commercial Cooking Equipment—with Revisions through November 2013

C403.7.5

727—06

Oil-fired Central Furnaces—with Revisions through October 2013

Table C403.3.2(4)

731—95

Oil-fired Unit Heaters—with Revisions through October 2013

Table C403.3.2(4)

1784—01

Air Leakage Tests of Door Assemblies—with Revisions through February 2015

C402.5.3

US-FTC

United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington DC20580

CFR Title 16 (2015)

R-value Rule

C303.1.4

WDMA

Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington DC20036-3309

AAMA/WDMA/CSA 101/I.S.2/A440—17

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

Table C402.5.2

UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING