Chapter 16 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

ASCE/SEIAmerican Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
Standard
reference
Number
Title Referenced
in code
section number
7—10Minimum Design Loads for Buildings and Other Structures with Supplement No. 1 301.1.4.1
31—03Seismic Evaluation of Existing Buildings 301.1.4, Table 301.1.4.2, 301.1.4.2
41—06Seismic Rehabilitation of Existing Buildings 301.1.4, 301.1.4.1, Table 301.1.4.1, 301.1.4.2, Table 301.1.4.2
ASHRAEAmerican Society of Heating, Refrigerating and Air Conditioning Engineers
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
Number
Title Referenced
in code
section number
62.1—2010 Ventilation for Acceptable Indoor Air Quality 809.2
ASMEAmerican Society of Mechanical Engineers
3 Park Avenue
New York, NY 10016
Standard
reference
Number
Title Referenced
in code
section number
ASME/ A17.1—2007/
CSA B44—2007
Safety Code for Elevators and Escalators—with A17.1a/CSA B44a—08 Addenda 410.8.2, 705.1.2, 902.1.2
A17.3—2008 Safety Code for Existing Elevators and Escalators 902.1.2
A18.1—2008 Safety Standard for Platform Lifts and Stairway Chair Lifts 410.8.3, 705.1.3
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
Number
Title Referenced
in code
section number
C 90—08 Standard Specification for Load-bearing Concrete Masonry Units A505.2.3
C 496—96 Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens A104, A106.3.3.2
E 519—00e1 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages A104, A106.3.3.2
DOCUnited States Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230
Standard
reference
Number
Title Referenced
in code
section number
PS 1—09 Structural Plywood A302
PS 2—10 Performance Standard for Wood-based Structural-use Panels A302
ICCInternational Code Council, Inc.
500 New Jersey Avenue, NW, 6th Floor
Washington, DC 20001
Standard
reference
Number
Title Referenced
in code
section number
IBC—12International Building Code®101, 106, 109, 110, 202, 301, 407, 410, 501, 601, 602,
606, 701, 702, 705, 706, 801, 802, 803, 804, 805, 806, 807,
904, 905, 907, 1001, 1002, 1007, 1011, 1012, 1102, 1103, 1104,
1201, 1202, 1203, 1204, 1205, 1301, 1302, 1201, 1501, 1506
ICC A117.1—2009Accessible and Usable Buildings and Facilities 410.6, 410.8.2, 705.1, 705.1.2, 705.1.3
IECC—12International Energy Conservation Code®702.4, 707.1, 811.1, 908.1
IFC—12International Fire Code®101.4.2, 301.1.1, 803.2.1, 803.2.3, 804.4.1.1, 804.4.1.2,
804.4.1.3, 804.4.1.4, 804.4.1.5, 804.4.1.6, 804.4.1.7, 804.4.3,
1301.2, 1401.3.2, 1401.6.8.1, 1401.6.14, 1401.6.14.1, 1504.1, 1504.2
IFGC—12International Fuel Gas Code®407.7, 702.4.1
IMC—12International Mechanical Code®407.8, 702.4, 809.1, 902.1.1, 1002.2.1, 1009.1,
1401.6.7.1, 1401.6.8, 1401.6.8.1
IPC—12International Plumbing Code®407.9, 609.1, 702.4, 810.1, 1010.2, 1010.3, 1010.5, 1501.5
IPMC—12International Property Maintenance Code®101.4.2, 1301.2, 1401.3.2
IRC—12International Residential Code®101.4.1, 602.3, 606, 706.2.1, 707.1,
807.4, 808.3, 811.1, 907.4, 907.4.2, 908.1, 1103.2, 1103.3, 1103.4,
1104.1, 1302.1, 1302.2, 1302.2.1, 1302.3, 1302.4, 1302.5, 1401.2.2, 1401.2.3
NFPANational Fire Protection Agency
1 Batterymarch Park
Quincy, MA 02269-9101
Standard
reference
Number —year of publication
Title Referenced
in code
section number
02-11Hydrogen Technologies Code101.8, 704.2
54-12National Fuel Gas Code101.8
NFPA 13R—10Installation of Sprinkler Systems in Residential Occupancies up to and
Including Four Stories in Height
804.2.5
NFPA 7014National Electrical Code 607.1.1, 607.1.2, 607.1.3, 607.1.4, 607.1.5
NFPA 72—10National Fire Alarm Code804.2.5, 804.4
NFPA 99—12Health Care Facilities607.1.4
NFPA 101—12Life Safety Code805.2
720-12Carbon Monoxide (CO) Detection and Warning Equipment403.7, 804.5, 1104.2