General site and building elements required to be accessible by the scoping provisions adopted by the administrative authority shall comply with the applicable provisions of Chapter 5.
Accessible car and van parking spaces shall comply with Section 502.

502.2 Vehicle Space Size

AMENDMENT
This section has been amended at the state or city level.
Pursuant to section 14-253a of the Connecticut General Statutes, car parking spaces shall be 15 feet in width including 5 feet of cross hatch. Van parking spaces shall be 16 feet in width including 8 feet of cross hatch.

Car and van parking spaces shall be marked to define the width. Where parking spaces are marked with lines, the width measurements of parking spaces and adjacent access aisles shall be made from the centerline of the markings.

EXCEPTION: Where parking spaces or access aisles are not adjacent to another parking space or access aisle, measurements shall be permitted to include the full width of the line defining the parking space or access aisle.

502.4 Access Aisle

AMENDMENT
This section has been amended at the state or city level.

Car and van parking spaces shall have an adjacent access aisle complying with Section 502.4.

502.4.1 Location

AMENDMENT
This section has been amended at the state or city level.
Access aisles (cross hatch) shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle. If a car and a van space share a common access aisle, that aisle shall be 96 inches minimum in width. Access aisles shall not overlap with the vehicular way. Parking spaces may have access aisles placed on either side of the car or van parking space. Van parking spaces that are angled shall have access aisles located on the passenger side of the parking space.

502.4.2 Width

AMENDMENT
This section has been amended at the state or city level.
Access aisles (cross hatch) serving car parking spaces shall be 60 inches (1525 mm) minimum in width. Access aisles serving van parking spaces shall be 96 inches (2440 mm) minimum in width.
Access aisles shall extend the full length of the parking spaces they serve.

Access aisles shall be marked so as to discourage parking in them. Where access aisles are marked with lines, the width measurements of access aisles and adjacent parking spaces shall be made from the centerline of the markings.

EXCEPTION: Where access aisles or parking spaces are not adjacent to another access aisle or parking space, measurements shall be permitted to include the full width of the line defining the access aisle or parking space.

Parking spaces and access aisles shall comply with Section 302 and have surface slopes not steeper than 1:48. Access aisles shall be at the same level as the parking spaces they serve.

502.6 Vertical Clearance

AMENDMENT
This section has been amended at the state or city level.
Vertical clearance for accessible van parking spaces shall be in accordance with Section 1106.5 and 1106.5.1.1 of the 2015 International Building Code portion of the 2018 Connecticut State Building Code.

502.7 Identification

AMENDMENT
This section has been amended at the state or city level.
Accessible parking spaces shall be identified by above grade signs in accordance with Section 1111.1 of the 2015 International Building Code portion of the 2018 Connecticut State Building Code.
Parking spaces and access aisles shall be designed so that cars and vans, when parked, cannot obstruct the required clear width of adjacent accessible routes.
Accessible passenger loading zones shall comply with Section 503.
Passenger loading zones shall provide a vehicular pull-up space 96 inches (2440 mm) minimum in width and 20 feet (6095 mm) minimum in length.

Passenger loading zones shall have an adjacent access aisle complying with Section 503.3.

FIG. 503.3

PASSENGER LOADING ZONE ACCESS AISLE

Access aisles shall adjoin an accessible route. Access aisles shall not overlap the vehicular way.
Access aisles serving vehicle pull-up spaces shall be 60 inches (1525 mm) minimum in width.
Access aisles shall be 20 feet (6095 mm) minimum in length.
Access aisles shall be marked so as to discourage parking in them.
Vehicle pull-up spaces and access aisles serving them shall comply with Section 302 and shall have slopes not steeper than 1:48. Access aisles shall be at the same level as the vehicle pull-up space they serve.

A vertical clearance of 114 inches (2895 mm) minimum shall be provided at the following locations:

  1. Vehicle pull-up spaces;
  2. The access aisles serving vehicle pull-up spaces;
  3. A vehicular route from an entrance to the passenger loading zone, and;
  4. A vehicular route from the passenger loading zone to a vehicular exit serving vehicle pull-up spaces.

504 Stairways

AMENDMENT
This section has been amended at the state or city level.

504.1 General

AMENDMENT
This section has been amended at the state or city level.

504.2 Treads and Risers

AMENDMENT
This section has been amended at the state or city level.

504.3 Open Risers

AMENDMENT
This section has been amended at the state or city level.

504.4 Tread Surface

AMENDMENT
This section has been amended at the state or city level.

504.5 Nosings

AMENDMENT
This section has been amended at the state or city level.

504.5.1 Visual Contrast

AMENDMENT
This section has been amended at the state or city level.

504.6 Handrails

AMENDMENT
This section has been amended at the state or city level.

504.7 Wet Conditions

AMENDMENT
This section has been amended at the state or city level.

504.8 Lighting

AMENDMENT
This section has been amended at the state or city level.

504.8.1 Illumination Level

AMENDMENT
This section has been amended at the state or city level.

504.8.2 Lighting Controls

AMENDMENT
This section has been amended at the state or city level.

504.9 Stair Level Identification

AMENDMENT
This section has been amended at the state or city level.

505.1 General

AMENDMENT
This section has been amended at the state or city level.
Handrails shall be provided in accordance with Section 1014 of the 2015 International Building Code portion of the 2018 Connecticut State Building Code.

505.1 General

AMENDMENT
This section has been amended at the state or city level.

505.2 Location

AMENDMENT
This section has been amended at the state or city level.

505.3 Continuity

AMENDMENT
This section has been amended at the state or city level.

505.4 Height

AMENDMENT
This section has been amended at the state or city level.

505.5 Clearance

AMENDMENT
This section has been amended at the state or city level.

505.6 Gripping Surface

AMENDMENT
This section has been amended at the state or city level.

505.7 Cross Section

AMENDMENT
This section has been amended at the state or city level.

505.7.1 Circular Cross Section

AMENDMENT
This section has been amended at the state or city level.

505.7.2 Noncircular Cross Sections

AMENDMENT
This section has been amended at the state or city level.

505.8 Surfaces

AMENDMENT
This section has been amended at the state or city level.

505.9 Fittings

AMENDMENT
This section has been amended at the state or city level.

505.10 Handrail Extensions

AMENDMENT
This section has been amended at the state or city level.

505.10.1 Top and Bottom Extension at Ramps

AMENDMENT
This section has been amended at the state or city level.

505.10.2 Top Extension at Stairs

AMENDMENT
This section has been amended at the state or city level.

505.10.3 Bottom Extension at Stairs

AMENDMENT
This section has been amended at the state or city level.
Accessible windows shall have operable parts complying with Section 309.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING