CODES

ADOPTS WITH AMENDMENTS:

International Building Code 2012 (IBC 2012)

Chapter 1 Scope and Administration

Chapter 2 Definitions

Chapter 3 Use and Occupancy Classification

Chapter 4 Special Detailed Requirements Based on Use and Occupancy

Chapter 5 General Building Heights and Areas

Chapter 6 Types of Construction

Chapter 7 Fire and Smoke Protection Features

Chapter 8 Interior Finishes

Chapter 9 Fire Protection Systems

Chapter 10 Means of Egress

Chapter 11 Accessibility

Chapter 12 Interior Environment

Chapter 13 Energy Efficiency

Chapter 14 Exterior Walls

Chapter 15 Roof Assemblies and Rooftop Structures

Chapter 16 Structural Design

Chapter 17 Special Inspections and Tests

Chapter 18 Soils and Foundations

Chapter 19 Concrete

Chapter 20 Aluminum

Chapter 21 Masonry

Chapter 22 Steel

Chapter 23 Wood

Chapter 24 Glass and Glazing

Chapter 25 Gypsum Board and Plaster

Chapter 26 Plastic

Chapter 27 Electrical

Chapter 28 Mechanical Systems

Chapter 29 Plumbing Systems

Chapter 30 Elevators and Conveying Systems

Chapter 31 Special Construction

Chapter 32 Encroachments Into the Public Right-Of-Way

Chapter 33 Safeguards During Construction

Chapter 34 Existing Buildings and Structures

Chapter 35 Referenced Standards

Appendix A Employee Qualifications

Appendix B Board of Appeals

Appendix C GROUP U—AGRICULTURAL BUILDINGS

Appendix D Fire Districts

Appendix E Supplementary Accessibility Requirements

Appendix F Rodentproofing

Appendix G Flood-Resistant Construction

Appendix H Signs

Appendix I Patio Covers

Appendix J Grading

Appendix K Administrative Provisions

Appendix L Earthquake Recording Instrumentation

Appendix M Tsunami-Generated Flood Hazard

Appendix N MUNICIPALITY – SPECIFIC STRUCTURAL DESIGN PARAMETERS

Chapter 35 Referenced Standards

AMENDMENT
This section has been amended at the state or city level. Amendments are shown in green text.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

AAAluminum Association
1525 Wilson Boulevard, Suite 600
Arlington, VA 22209
Standard
reference
number
TitleReferenced
in code
section number
ADM1—2010Aluminum Design Manual: Part 1—A Specification for Aluminum Structures1604.3.5, 2002.1
ASM 35—00Aluminum Sheet Metal Work in Building Construction (Fourth Edition) 2002.1
AAMAAmerican Architectural Manufacturers Association
1827 Waldon Office Square, Suite 550
Schaumburg, IL 60173
Standard
reference
number
TitleReferenced
in code
section number
1402—86Standard Specifications for Aluminum Siding, Soffit and Fascia1404.5.1
AAMA/WDMA/CSA 101/I.S.2/A440—11North American Fenestration Standard/Specifications for Windows, Doors and Skylights1710.5.1, 2405.5
ACIAmerican Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
Title Referenced
in code
section number
216.1—07Standard Method for Determining Fire Resistance of Concrete and Masonry Construction AssembliesTable 721.1(2), 722.1
318—11Building Code Requirements for Structural Concrete1604.3.2, 1615.3.1, 1615.4.1, Table 1705.2.2, 1705.2.2.1.2, Table 1705.3, 1705.3.1,
1705.12.1, 1808.8.2, Table 1808.8.2, 1808.8.5, 1808.8.6,
1810.1.3, 1810.2.4.1, 1810.3.2.1.1, 1810.3.2.1.2, 1810.3.8.3.1, 1810.3.8.3.3,
1810.3.9.4.2.1, 1810.3.9.4.2.2, 1810.3.10.1, 1810.3.11.1, 1901.2,
1902.1, 1903.1, 1904.1, 1904.2, Table 1904.2, 1905.1, 1905.1.1, 1905.1.2,
1905.1.3, 1905.1.4, 1905.1.5, 1905.1.6, 1905.1.7, 1905.1.8, 1905.1.10,
1906.1, 1909.1, 2108.3, 2206.1
530—11Building Code Requirements for Masonry Structures1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4, 1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9
2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2103.9, 2103.12
2103.13, 2103.14, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.2, 2104.3, 2104.4,
2105.2.2.1, 2105.2.2.1.2, 2105.2.2.1.3, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4,
2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2109.3, 2110.1
530.1—11Specifications for Masonry Structures1405.6.1, 1705.4, 1807.1.6.3,
2103.9, 2103.12, 2103.13, 2103.14, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.2,
2104.3, 2104.4, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
AF&PAAmerican Forest & Paper Association
1111 19th St, NW Suite 800
Washington, DC 20036
Standard
reference
number
TitleReferenced
in code
section number
WCD No. 4—2003
ANSI/AF&PA
Wood Construction Data—Plank and Beam Framing for Residential Buildings2306.1.2
WFCM—2012Wood Frame Construction Manual for One- and Two-Family Dwellings1609.1.1, 1609.1.1.1, 2301.2, 2308.1, 2308.2.1
NDS—2012National Design Specification (NDS) for Wood Construction with 2012 Supplement722.1, 722.6.3.2, 1711.1.1, 1711.1.2.1, 1809.12, 1810.3.2.4, Table 1810.3.2.6, 1905.1.9, 2302.1, 2304.12, 2306.1, 2306.2, Table 2306.2(1), Table 2306.2(2), Table 2306.3(1), Table 2306.3(2), 2307.1
AF&PA—2012
ANSI/AF&PA
Span Tables for Joists and Rafters202, 2306.1.1, 2308.8, 2308.10.2, 2308.10.3
PWF—2007
ANSI/AF&PA
Permanent Wood Foundation Design Specification1805.2, 1807.1.4, 2304.9.5.2
SDPWS—2008Special Design Provisions for Wind and Seismic202, 2305.1, 2305.2, 2305.3, 2306.2, 2306.3, Table 2306.3(1), Table 2306.3(3), 2307.1
AISCAmerican Institute of Steel
Construction One East Wacker Drive, Suite 700
Chicago, IL 60601-18021
Standard
reference
number
TitleReferenced
in code
section number
ANSI/AISC 341—10Seismic Provisions for Structural Steel Buildings1613.4.1, 1705.11.1, 1705.12.2, 2205.2.1, 2205.2.2, 2206.2
ANSI/AISC 360—10Specification for Structural Steel Buildings722.5.2.2.1, 1604.3.3, 1705.2.1, 2203.1, 2203.2, 2205.1, 2205.2.1, 2206.1
AISIAmerican Iron and Steel Institute
1140 Connecticut Avenue, 705
Suite 705
Washington, DC 20036
Standard
reference
number
TitleReferenced
in code
section number
AISI S100—07/S2—10North American Specification for the Design of Cold-formed Steel Structural Members, with Supplement 2, dated 20101604.3.3, 1905.1.9, 2203.1, 2203.2, 2210.1, 2210.2, 2211.2, 2211.4, 2211.6
AISI S110—07/S1—09Standard for Seismic Design of Cold-formed Steel Structural Systems—Special Bolted Moment Frames, with Supplement 1, dated 20092210.2
AISI S200—07North American Standard for Cold-formed Steel Framing-General Provisions2203.1, 2203.2, 2211.1
AISI S210—07North American Standard for Cold-formed Steel Framing-Floor and Roof System Design2211.5
AISI S211—07North American Standard for Cold-formed Steel Framing-Wall Stud Design2211.4
AISI S212—07North American Standard for Cold-formed Steel Framing-Header Design2211.2
AISI S213—07/S1—09North American Standard for Cold-formed Steel Framing-Lateral Design, with Supplement 1, dated 20092211.6
AISI S214—07/S2—08North American Standard for Cold-formed Steel Framing-Truss
Design, with Supplement 2, dated 2008
2211.3, 2211.3.1, 2211.3.2
AISI S230—07/S2—08Standard for Cold-formed Steel Framing-Prescriptive Method for One- and Two-family Dwellings, with Supplement 2, dated 20081609.1.1, 1609.1.1.1, 2211.7
AITCAmerican Institute of Timber Construction
Suite 140
7012 S. Revere Parkway
Englewood, CO 80112
Standard
reference
number
TitleReferenced
in code
section number
AITC Technical
Note 7—96
Calculation of Fire Resistance of Glued Laminated Timbers 722.6.3.3
AITC 104—03Typical Construction Details2306.1
AITC 110—01Standard Appearance Grades for Structural Glued Laminated Timber2306.1
AITC 113—10Standard for Dimensions of Structural Glued Laminated Timber 2306.1
AITC 117—10Standard Specifications for Structural Glued Laminated Timber of Softwood Species2306.1
AITC 119—96
ANSI/AITC
Standard Specifications for Structural Glued Laminated Timber of Hardwood Species2306.1
A 190.1—07Structural Glued Laminated Timber2303.1.3, 2306.1
AITC 200—09Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber2306.1
ALIAutomotive Lift Institute
P.O. Box 85
Courtland, NY 13045
Standard
reference
number
TitleReferenced
in code
section number
ALI ALCTV—2006Standard for Automotive Lifts—Safety Requirements for Construction, Testing and Validation (ANSI)3001.2
AMCAAir Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
Standard
reference
number
TitleReferenced
in code
section number
540—08Test Method for Louvers Impacted by Wind Borne Debris1609.1.2.1
ANSIAmerican National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
TitleReferenced
in code
section number
A13.1—96
(Reaffirmed 2002)
Scheme for the Identification of Piping Systems415.10.6.5
A108.1A—99Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar2103.11
A108.1B—99Installation of Ceramic Tile, quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex-portland Mortar2103.11
A108.4—99Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive2103.11.6
A108.5—99Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-Portland Cement Mortar2103.11.1, 2103.11.2
A108.6—99Installation of Ceramic Tile with Chemical-resistant, Water Cleanable Tile-setting and -grouting Epoxy2103.11.3
A108.8—99Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout2103.11.4
A108.9—99Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout2103.11.5
A108.10—99Installation of Grout in Tilework2103.11.7
A118.1—99American National Standard Specifications for Dry-set Portland Cement Mortar2103.11.1
A118.3—99American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive2103.11.3
A118.4—99American National Standard Specifications for Latex-portland Cement Mortar2103.11.2
A118.5—99American National Standard Specifications for Chemical Resistant Furan Mortar and Grouts for Tile Installation2103.11.4
A118.6—99American National Standard Specifications for Cement Grouts for Tile Installation2103.11.7
A118.8—99American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout2103.11.5
A136.1—99American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile2103.11.6
A137.1—08American National Standard Specifications for Ceramic Tile202, 2103.6
A208.1—09Particleboard2303.1.7, 2303.1.7.1
Z 97.1—09Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test2406.1.2, 2406.2, Table 2406.2(2), 2406.3.1, 2407.1, 2407.1.4.1,
2408.2.1, 2408.3, 2409.1, 2409.2, 2409.3.1
APAAPA - Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
Standard
reference
number
TitleReferenced
in code
section number
ANSI/APA PRP 210—08Standard for Performance-Rated Engineered Wood Siding2303.1.4, 2304.6.2, 2306.3, Table 2306.3(1)
APA PDS—04Panel Design Specification2306.1
APA PDS
Supplement 1—90
Design and Fabrication of Plywood Curved Panels (revised 1995)2306.1
APA PDS
Supplement 2—92
Design and Fabrication of Plywood-lumber Beams (revised 1998)2306.1
APA PDS
Supplement 3—90
Design and Fabrication of Plywood Stressed-skin Panels (revised 1996)2306.1
APA PDS
Supplement 4—90
Design and Fabrication of Plywood Sandwich Panels (revised 1993)2306.1
APA PDS
Supplement 5—08
Design and Fabrication of All-plywood Beams (revised 2008)2306.1
EWS R540—02Builders Tips: Proper Storage and Handling of Glulam Beams2306.1
EWS S475—01Glued Laminated Beam Design Tables2306.1
EWS S560—03Field Notching and Drilling of Glued Laminated Timber Beams2306.1
EWS T300—05Glulam Connection Details2306.1
EWS X440—03Product Guide-Glulam2306.1
EWS X450—01Glulam in Residential Construction-Western Edition2306.1
APSPThe Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314
Standard
reference
number
TitleReferenced
in code
section number
ANSI/APSP 7—06Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs and Catch Basins3109.5
ASABEAmerican Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph, MI 49085
Standard
reference
number
TitleReferenced
in code
section number
EP 484.2 June
1998 (R2008)
Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings2306.1
EP 486.1 Dec
1999 (R2005)
Shallow-post Foundation Design2306.1
EP 559 1997
Dec 1996
(R2008)
Design Requirements and Bending Properties for Mechanically Laminated Columns2306.1
ASCE / SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
Standard
reference
number
Title Referenced
in code
section number
5—11Building Code Requirements for Masonry Structures 1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4, 1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9,
2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2103.9, 2103.12,
2103.13, 2103.14, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.2, 2104.3, 2104.4,
2105.2.2.1, 2105.2.2.1.2, 2105.2.2.1.3, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4,
2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2109.3, 2110.1
6—11Specification for Masonry Structures 1405.6.1, 1705.4, 1807.1.6.3, 2103.9, 2103.12, 2103.13, 2103.14, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.2,
2104.3, 2104.4, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
7—10Minimum Design Loads for Buildings and Other Structures 202, Table 1504.8, 1602.1, 1604.3, Table 1604.5, 1604.8.2, 1604.10, 1605.1, 1605.2.1, 1605.3.1, 1605.3.1.2,
1605.3.2, 1605.3.2.1, 1607.8.1, 1607.8.1.1, 1607.8.1.2, 1607.8.3, 1607.12.1,
1608.1, 1608.2, 1608.3, 1609.1.1, 1609.1.2, 1609.3, 1609.5.1, 1609.5.3, 1609.6,
1609.6.1, 1609.6.1.1, 1609.6.2, Table 1609.6.2, 1609.6.3, 1609.6.4.1, 1609.6.4.2,
1609.6.4.4.1, 1611.2, 1612.4, 1613.1, 1613.3.2, Table 1613.3.3(1), Table 1613.3.3(2),
1613.3.5, 1613.3.5.1, 1613.3.5.2, 1613.4, 1613.4.1, 1614.1, 1705.11, 1705.12,
1705.12.3, 1705.12.4, 1803.5.12, 1808.3.1, 1810.3.6.1, 1810.3.9.4, 1810.3.11.2,
1810.3.12, 1905.1.1, 1905.1.2, 1905.1.9, 2205.2.1, 2205.2.2, 2206.2, 2209.1, 2210.2,
2304.6.1, 2404.1, 2505.1, 2505.2, 2506.2.1, 3404.4, 3404.5
8—02Standard Specification for the Design of Cold-formed
Stainless Steel Structural Members
1604.3.3, 2210.1, 2210.2
19—10Structural Applications of Steel Cables for Buildings 2208.1, 2208.2
24—05Flood Resistant Design and Construction 1203.3.2, 1612.4, 1612.5, 3001.2, G103.1, G401.3, G401.4
29—05Standard Calculation Methods for Structural Fire Protection 722.1
32—01Design and Construction of Frost Protected Shallow Foundations 1809.5
ASMEAmerican Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
TitleReferenced
in code
section number
ASME/A17.1
2007/CSA B44—07
ASME A17.1 - 96
Safety Code for Elevators and Escalators – with A17.1a/CSA B44a-08 AddendaSafety Code for Elevators and Escalators with the 1997 and 1998 addenda907.3.3, 911.1.5, 1007.4, 1607.9.1, 3001.2, 3001.4, 3002.5,
3003.2, 3007.1, 3007.2, 3008.2, 3008.2.1, 3008.7.6, 3008.8.1, 3411.8.2
A18.1—2008Safety Standard for Platform Lifts and Stairway Chairlifts1109.8, 2702.2.6, 3411.8.3
A90.1—09Safety Standard for Belt Manlifts3001.2
B16.18—2001
(Reaffirmed 2005)
Cast Copper Alloy Solder Joint Pressure Fittings909.13.1
B16.22—2001
(Reaffirmed 2005)
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings909.13.1
B20.1—2009Safety Standard for Conveyors and Related Equipment 3005.3
B31.3—2004Process Piping415.10.6
ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A 36/A 36M—08 Specification for Carbon Structural Steel 1810.3.2.3
A 153/A 153M—05 Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware 2304.9.5
A 240/A 240M—09a Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications Table 1507.4.3(1)
A 252—98 (2007) Specification for Welded and Seamless Steel Pipe Piles 1810.3.2.3
A 283/A 283M—03(2007) Specification for Low and Intermediate Tensile Strength Carbon Steel Plates 1810.3.2.3
A 307—07b Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength 1908.1
A 416/A 416M—06 Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete 1810.3.2.2
A 463/A 463M—06 Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process Table 1507.4.3(2)
A 572/A 572M—07 Specification for High-strength Low-alloy Columbium-vanadium Structural Steel 1810.3.2.3
A 588/A 588M—05 Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point with Atmospheric Corrosion Resistance 1810.3.2.3
A 615/A 615M—09 Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement 1705.12.1,1810.3.10.2
A 653/A 653M—08 Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process Table 1507.4.3(1), Table 1507.4.3(2),2304.9.5.1
A 690/A 690M—07 Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel H-piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Marine Environments 1810.3.2.3
A 706/A 706M—09 Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement Table 1705.2.2,1705.3.1,2107.4,2108.3
A 722/A 722M—07 Specification for Uncoated High-strength Steel Bar for Prestressing Concrete 1810.3.10.2
A 755/A 755M—03(2008) Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products Table 1507.4.3(1), Table 1507.4.3(2)
A 792/A 792M—08 Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process Table 1507.4.3(1), Table 1507.4.3(2)
A 875/A 875M—06 Standard Specification for Steel Sheet Zinc-5 percent, Aluminum Alloy-coated by the Hot-dip Process Table 1507.4.3(2)
A 913/A 913M—07 Specification for High-strength Low-alloy Steel Shapes of Structural Quality, Produced by Quenching and Self-tempering Process (QST) 1810.3.2.3
A 924/A 924M—08a Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process Table 1507.4.3(1)
A 992/A 992M—06a Standard Specification for Structural Shapes 1810.3.2.3
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes 909.13.1
B 43—98(2004) Specification for Seamless Red Brass Pipe, Standard Sizes 909.13.1
B 68—02 Specification for Seamless Copper Tube, Bright Annealed (Metric) 909.13.1
B 88—03 Specification for Seamless Copper Water Tube 909.13.1
B 101—07 Specification for Lead-coated Copper Sheet and Strip for Building Construction 1404.5.3, Table1507.2.9.2,
Table 1507.4.3(1)
B 209—07 Specification for Aluminum and Aluminum Alloy Steel and Plate Table 1507.4.3(1)
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube 909.13.1
B 280—03 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service 909.13.1
B 370—09 Specification for Cold-rolled Copper Sheet and Strip for Building Construction 1404.5.2, Table1507.2.9.2, Table 1507.4.3(1)
B 695—04 Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel Strip for Building Construction 2304.9.5.1,2304.9.5.3
C 5—03 Specification for Quicklime for Structural Purposes Table 2507.2
C 22/C 22M—00 (2005) e01 Specification for Gypsum Table 2506.2
C 27—98(2008) Specification for Standard Classification of Fireclay and High-alumina Refractory Brick 2111.5
C 28/C 28M—00 (2005) Specification for Gypsum Plasters Table 2507.2
C 31/C 31M—08b Practice for Making and Curing Concrete Test Specimens in the Field Table 1705.3
C 33/C33M—08 Specification for Concrete Aggregates 722.3.1.4,722.4.1.1.3
C 34—03 Specification for Structural Clay Load-bearing Wall Tile 2103.2
C 35—01(2005) Specification for Inorganic Aggregates for Use in Gypsum Plaster Table 2507.2
C 55—06e01 Specification for Concrete Building Brick Table 722.3.2, 2103.1, 2105.2.2.1.2
C 56—05 Specification for Structural Clay Nonload Bearing Tile 2103.2
C 59/C 59M—00 (2006) Specification for Gypsum Casting and Molding Plaster Table 2507.2
C 61/C 61M—00 (2006) Specification for Gypsum Keene’s Cement Table 2507.2
C 62—08 Specification for Building Brick (Solid Masonry Units Made from Clay or Shale) 1807.1.6.3,2203.2,2105.2.2.1.1
C 67—08 Test Methods of Sampling and Testing Brick and Structural Clay Tile 721.4.1.1.1,2109.3.1.1
C 73—05 Specification for Calcium Silicate Face Brick (Sand-lime Brick) Table 722.3.2,2103.1
C 90—08 Specification for Loadbearing Concrete Masonry Units Table 722.3.2,1807.1.6.3,2103.1
C 91—05 Specification for Masonry Cement Table 2507.2
C 94/C 94M—09 Specification for Ready-mixed Concrete 110.3.1
C 126—99 (2005) Specification for Ceramic Glazed Structural
Clay Facing Tile, Facing Brick and Solid Masonry Units
2103.2
C 140—08a Test Method Sampling and Testing Concrete Masonry Units and Related Units 722.3.1.2
C 150—07 Specification for Portland Cement Table 2507.2
C 172—08 Practice for Sampling Freshly Mixed Concrete Table 1705.3
C 199—84 (2005) Test Method for Pier Test for Refractory Mortars 2111.5,2111.8,2113.12
C 206—03 Specification for Finishing Hydrated Lime Table 2507.2
C 208—08a Specification for Cellulosic Fiber Insulating Board Table 1508.2,2303.1.5
C 212—00 (2006) Specification for Structural Clay Facing Tile 2103.2
C 216—07a Specification for Facing Brick
(Solid Masonry Units Made from Clay or Shale)
1807.1.6.3,2103.2,2105.2.2.1.1
C 270—08a Specification for Mortar for Unit Masonry 2103.9
C 315—07 Specification for Clay Flue Liners and Chimney Pots 2111.8,2113.11.1, Table 2113.16(1)
C 317/C 317M—00 (2005) Specification for Gypsum Concrete 1911.1
C 330—05 Specification for Lightweight Aggregates for Structural Concrete 202
C 331—05 Specification for Lightweight Aggregates for Concrete Masonry Units 722.3.1.4,722.4.1.1.3
C 406—06e01 Specification for Roofing Slate 1507.7.5
C 472—99 (2004) Specification for Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete Table 2506.2
C 473—07 Test Method for Physical Testing of Gypsum Panel Products Table 2506.2
C 474—05 Test Methods for Joint Treatment Materials for Gypsum Board Construction Table 2506.2
C 475/C 475M—02 (2007) Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard Table 2506.2
C 503—08a Specification for Marble Dimension Stone (Exterior) 2103.4
C 514—04 Specification for Nails for the Application of Gypsum Board Table 721.1(2), Table 721.1(3), Table 2306.7, Table 2506.2
C 516—08a Specifications for Vermiculite Loose Fill Thermal Insulation 722.3.1.4,722.4.1.1.3
C 547—07e1 Specification for Mineral Fiber Pipe Insulation Table 721.1(2), Table 721.1(3)
C 549—06 Specification for Perlite Loose Fill Insulation 722.3.1.4,722.4.1.1.3
C 552—07 Standard Specification for Cellular Glass Thermal Insulation Table 1508.2
C 557—03e01 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing Table 2506.2
C 568—08a Specification for Limestone Dimension Stone 2103.4
C 578—08b Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation Table 1508.2
C 587—04 Specification for Gypsum Veneer Plaster Table 2507.2
C 595—08a Specification for Blended Hydraulic Cements Table 2507.2
C 615—03 Specification for Granite Dimension Stone 2103.4
C 616—08a Specification for Quartz Dimension Stone 2103.4
C 629—08 Specification for Slate Dimension Stone 2103.4
C 631—09 Specification for Bonding Compounds for Interior Gypsum Plastering Table 2507.2
C 635/C635M—07 Specification for the Manufacture, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings 808.1.1,2506.2.1,H107.1.1
C 636/C 636M—08 Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels 808.1.1.1
C 645—08a Specification for Nonstructural Steel Framing Members Table 2506.2, Table2507.2
C 652—09 Specification for Hollow Brick (Hollow Masonry
Units Made from Clay or Shale)
1807.1.6.3, 2103.2, 2105.2.2.1.1
C 726—05e1 Standard Specification for Mineral Fiber Roof Insulation Board Table 1508.2
C 728—05 Standard Specification for Perlite Thermal Insulation Board Table 1508.2
C 744—08 Specification for Prefaced Concrete and Calcium Silicate Masonry Units Table 722.3.2,2103.1
C 754—08 Specification for Installation of Steel Framing Members to Receive Screw-attached Gypsum Panel Products Table 2508.1, Table2511.1.1
C 836—06 Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course 1507.15.2
C 840—08 Specification for Application and Finishing of Gypsum Board Table 2508.1,2509.2
C 841—03 (2008) e1 Specification for Installation of Interior Lathing and Furring Table 2508.1, Table2511.1.1
C 842—05 Specification for Application of Interior Gypsum Plaster Table 2511.1.1,2511.3,2511.4
C 843—99 (2006) Specification for Application of Gypsum Veneer Plaster Table 2511.1.1
C 844—04 Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster Table 2508.1
C 847—09 Specification for Metal Lath Table 2507.2
C 887—05 Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar 1805.2.2,2103.10
C 897—05 Specification for Aggregate for Job-Mixed Portland Cement-based Plaster Table 2507.2
C 920—08 Standard for Specification for Elastomeric Joint Sealants Table 2506.2
C 926—06 Specification for Application of Portland Cement-based Plaster 2109.3.4.8,2510.3, Table2511.1.1,2511.3,2511.4,2512.1,
2512.1.2,2512.2,2512.6,2512.8.2,2512.9,2513.7
C 932—06 Specification for Surface-applied Bonding Compounds Agents for Exterior Plastering Table 2507.2
C 933—07b Specification for Welded Wire Lath Table 2507.2
C 946—91 (2001) Specification for Practice for Construction of Dry-stacked, Surface-bonded Walls 2103.10,2109.2.2
C 954—07 Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to 0.112 inch (2.84 mm) in Thickness Table 2506.2, Table2507.2
C 955—09 Standard Specification for Load-bearing Transverse and Axial Steel Studs, Runners Tracks, and Bracing or Bridging, for Screw Application of Gypsum Panel Products and Metal Plaster Bases Table 2506.2, Table2507.2
C 956—04 Specification for Installation of Cast-in-place Reinforced Gypsum Concrete 1911.1
C 957—06 Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane with Integral Wearing Surface 1507.15.2
C 1002—07 Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs Table 2506.2, Table2507.2
C 1007—08a Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories Table 2508.1, Table2511.1.1
C 1019—09 Test Method of Sampling and Testing Grout 2105.2.2.1.1,2105.2.2.1.2,2105.2.2.1.3
C 1029—08 Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation 1507.14.2
C 1032—06 Specification for Woven Wire Plaster Base Table 2507.2
C 1047—09 Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base Table 2506.2, Table2507.2
C 1063—08 Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster 2109.3.4.8,2510.3, Table2511.1.1,2512.1.1
C 1088—09 Specification for Thin Veneer Brick Units Made from Clay or Shale Table 721.1(2),2103.2
C 1167—03 Specification for Clay Roof Tiles 1507.3.4
C 1177/C 1177M—08 Specification for Glass Mat Gypsum Substrate for Use as Sheathing Table 2506.2
C 1178/C 1178M—06 Specification for Coated Mat Water-resistant Gypsum Backing Panel Table 2506.2,2509.2
C 1186—08 Specification for Flat Fiber Cement Sheets 1404.10,1405.16.1,1405.16.2
C 1261—07 Specification for Firebox Brick for Residential Fireplaces 2111.5,2111.8
C 1278/C 1278M—07a Specification for Fiber-reinforced Gypsum Panels Table 2506.2
C 1280—09 Specification for Application of Gypsum Sheathing Table 2508.1,2508.2
C 1283—07a Practice for Installing Clay Flue Lining 2113.9.1,2113.12
C 1288—99 (2004) e1 Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets 2509.2
C 1289—08 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board Table 1508.2
C 1314—07 Test Method for Compressive Strength of Masonry Prisms 2105.2.2.2.2,2105.3.1,2105.3.2
C 1325—08b Standard Specification for Nonasbestos Fiber-mat Reinforced Cementitious Backer Units 2509.2
C 1328—05 Specification for Plastic (Stucco Cement) Table 2507.2
C 1364—07 Standard Specification for Architectural Cast Stone 2103.5
C 1386—07 Specification for Precast Autoclaved Aerated Concrete (AAC) Wall Construction Units 202,2103.3,2105.2.2.1.3
C 1396/C 1396M—06a Specification for Gypsum Board Figure 722.5.1(2), Figure 722.5.1(3), Table2506.2
C 1405—08 Standard Specification for Glazed Brick (Single Fired, Solid Brick Units) 2103.2
C 1492—03 Standard Specification for Concrete Roof Tile 1507.3.5
C 1629/C 1629M—06 Standard Classification for Abuse-resistant Nondecorated Interior Gypsum Panel Products and Fiber-reinforced Cement Panels 403.2.3.1,403.2.3.2,403.2.3.4
C 1658/C 1658M—06 Standard Specification for Glass Mat Gypsum Panels Table 2506.2
D 25—99 (2005) Specification for Round Timber Piles 1810.3.2.4,2303.1.11
D 41—05 Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 43—00 (2006) Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 56—05 Test Method for Flash Point By Tag Closed Tester 202
D 86—09 Test Method for Distillation of Petroleum Products at Atmospheric Pressure 202
D 93—08 Test Method for Flash Point By Pensky-Martens Closed Cup Tester 202
D 225—07 Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules 1507.2.5
D 226—06 Specification for Asphalt-saturated Organic Felt Used in Roofing and Waterproofing 1404.2,1507.2.3,1507.2.8.1,1507.3.3,1507.4.5
1507.5.3,1507.6.3,1507.6.3.1,1507.7.3, Table1507.8, 1507.8.31507.9.3,1507.9.5, Table1507.10.2
D 227—03 Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing Table 1507.10.2
D 312—00 (2006) Specification for Asphalt Used in Roofing Table 1507.10.2
D 422—63 (2007) Test Method for Particle-size Analysis of Soils 1803.5.3
D 448—08 Standard Classification for Sizes of Aggregate for Road and Bridge Construction 1507.12.3,1507.13.3
D 450—07 Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 635—06 Test Method for Rate of Burning and/or Extent and Time of Burning of Self-supporting Plastics in a Horizontal Position 2606.4,H107.1.1
D 1143/D 1143M—07e1 Test Method for Piles Under Static Axial Compressive Load 1810.3.3.1.2
D 1227—95 (2007) Specification for Emulsified Asphalt Used as a Protective Coating for Roofing Table 1507.10.2,1507.15.2
D 1557—07 Test Method for Laboratory Compaction Characteristics of Soil Using Modified Effort [56,000 ft-lb/ft3(2,700 KN m/m3)] 1705.6,1804.5,J107.5
D 1761—06 Test Method for Mechanical Fasteners in Wood 1711.1.1,1711.1.2,1711.1.3
D 1863—05 Specification for Mineral Aggregate Used on Built-up Roofs Table 1507.10.2
D 1929—96 (2001) e01 Test Method for Determining Ignition Properties of Plastics 402.6.4.4,406.7.2,1407.11.2.1,1407.11.3.3,1407.11.4.2,2606.4
D 1970—09 Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection 1507.2.4,1502.2.8.1,1507.2.9.2,1507.3.3.3
1507.3.9,1507.4.5,1507.5.3.1,1507.5.7,1507.6.3.1,
1507.7.3.1,1507.8.3.1,1507.8.8,1507.9.3.1,1507.9.9
D 2178—04 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D 2487—06e1 Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System) Table 1610.1,1803.5.1
D 2626—04 Specification for Asphalt Saturated and Coated
Organic Felt Base Sheet Used in Roofing
1507.3.3, Table1507.10.2
D 2822—05 Specification for Asphalt Roof Cement, Asbestos Containing Table 1507.10.2
D 2823—05 Specification for Asphalt Roof Coatings, Asbestos Containing Table 1507.10.2
D 2824—06 Standard Specification for Aluminum-Pigmented Asphalt Roof Coating, Nonfibered, Asbestos Fibered and Fibered without Asbestos Table 1507.10.2
D 2843—99 (2004) e01 Test for Density of Smoke from the Burning or Decomposition of Plastics 2606.4
D 2859—06 Standard Test Method for Ignition Characteristics of Finished
Textile Floor Covering Materials
804.4.1
D 2898—08e01 Test Methods for Accelerated Weathering of Fire-retardant-
treated Wood for Fire Testing
1505.1,2303.2.4,2303.2.6
D 3019—08 Specification for Lap Cement Used with Asphalt Roll Roofing,
Nonfibered, Asbestos Fibered and Nonasbestos Fibered
Table 1507.10.2
D 3161—09 Test Method for a Wind Resistance of Asphalt Shingles
(Fan Induced Method)
1507.2.7.1, Table 1507.2.7.1(2)
D 3200—74 (2005) Standard Specification and Test Method for Establishing Recommended Design Stresses for Round Timber Construction Poles 2303.1.11
D 3201—08a Test Method for Hygroscopic Properties of Fire-retardant-treated
Wood and Wood-based Products
2303.2.7
D 3278—96 (2004) Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 202
D 3462—09 Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules 1507.2.5
D 3468—99 (2006) e01 Specification for Liquid-applied Neoprene and
Chlorosulfonated Polyethylene Used in Roofing and Waterproofing
1507.15.2
D 3679—09 Specification for Rigid Poly [Vinyl Chloride (PVC) Siding] 1404.9,1405.14
D 3689—07 Test Methods for Deep Foundations Under Static Axial Tensile Load 1810.3.3.1.5
D 3737—08 Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam) 2303.1.3
D 3746—85 (2008) Test Method for Impact Resistance of Bituminous Roofing Systems 1504.7
D 3747—79 (2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table 1507.10.2
D 3909—97b (2004) Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules 1507.2.9.2,1507.6.5, Table1507.10.2
D 3957—06 Standard Practices for Establishing Stress Grades
for Structural Members Used in Log Buildings
2303.1.10
D 4022—07 Specification for Coal Tar Roof Cement, Asbestos Containing Table 1507.10.2
D 4272—08a Test Method for Total Energy Impact of Plastic Films by Dart Drop 1504.7
D 4318—05 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils 1803.5.3
D 4434/D4434M—09 Specification for Poly (Vinyl Chloride) Sheet Roofing 1507.13.2
D 4479—07 Specification for Asphalt Roof Coatings-Asbestos-free Table 1507.10.2
D 4586—07 Specification for Asphalt Roof Cement-Asbestos-free Table 1507.10.2
D 4601—04 Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table 1507.10.2
D 4637—08 Specification for EPDM Sheet Used in Single-ply Roof Membrane 1507.12.2
D 4829—08a Test Method for Expansion Index of Soils 1803.5.3
D 4869—05e01 Specification for Asphalt-saturated (Organic Felt)
Underlayment Used in Steep Slope Roofing
1507.2.3,1507.2.8.1,1507.4.5,1507.5.3,
1507.5.3.1,1507.6.3,1507.7.3,1507.7.3.1,
1507.8.3,1507.8.3.1,1507.9.3,1507.9.3.1
D 4897—01 Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing Table 1507.10.2
D 4945—08 Test Method for High-strain Dynamic Testing of Piles 1810.3.3.1.2
D 4990—97a (2005) e01 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D 5019—07a Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane 1507.12.2
D 5055—09 Specification for Establishing and Monitoring Structural
Capacities of Prefabricated Wood I-joists
2303.1.2
D 5456—09 Specification for Evaluation of Structural Composite Lumber Products 2303.1.9
D 5516—03 Test Method of Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures 2303.2.5.1
D 5643—06 Specification for Coal Tar Roof Cement, Asbestos-free Table 1507.10.2
D 5664—08 Test Methods for Evaluating the Effects of Fire-retardant Treatment and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber 2303.2.5.2
D 5665—99a (2006) Specification for Thermoplastic Fabrics Used in Cold-applied
Roofing and Waterproofing
Table 1507.10.2
D 5726—98 (2005) Specification for Thermoplastic Fabrics Used in Hot-applied
Roofing and Waterproofing
Table 1507.10.2
D 6083—05e01 Specification for Liquid Applied Acrylic Coating Used in Roofing Table 1507.10.2, Table 1507.14.3,1507.15.2
D 6162—00A (2008) Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements 1507.11.2
D 6163—00 (2008) Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements 1507.11.2
D 6164—05e1 Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Metal Materials Using Polyester Reinforcements 1507.11.2
D 6222—08 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements 1507.11.2
D 6223—02 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements 1507.11.2
D 6298—05e1 Specification for Fiberglass Reinforced Styrene-butadiene-styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface 1507.11.2
D 6305—08 Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing 2303.2.5.1
D 6380—03 (2009) Standard Specification for Asphalt Roll Roofing (Organic) Felt 1507.2.9.2,1507.3.3,1507.6.5
D 6509/D6509M—09 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous base Sheet Materials Using Glass Fiber Reinforcements 1507.11.2
D 6694—08 Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Table 1507.14.3,1507.15.2
D 6754—02 Standard Specification for Ketone Ethylene Ester Based Sheet Roofing 1507.13.2
D 6757—07 Standard Specification for Inorganic Underlayment for Use with Steep Slope Roofing Products 1507.2.3
D 6841—08 Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber 2303.2.5.2
D 6878—08e1 Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing 1507.13.2
D 6947—07 Standard Specification for Liquuid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System Table 1507.14.3,1507.15.2
D 7158—08d Standard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift Force/Uplift Resistance Method) 1507.2.7.1, Table 1507.2.7.1(1)
D 7254—07 Standard Specification for polypropylene (PP) siding 1404.12
E 84—09 Test Methods for Surface Burning Characteristics of Building Materials 202,402.6.4.4,406.7.2,703.5.2,
720.1,720.4,803.1.1,803.1.4,803.9,803.13,
806.5,1404.12.1,1407.9,1407.10.1,1409.9,1409.10.1,
1509.6.2,1509.6.3,2303.2,2603.3,2603.4.1.13,2606.3.5.4,
2603.7,2604.2.4,2606.4,2613.3,3105.4
E 90—04 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements 1207.2,1207.2.1
E 96/E 96M—05 Test Method for Water Vapor Transmission of Materials 202
E 108—07a Test Methods for Fire Tests of Roof Coverings 1505.1,2603.6,2610.2,2610.3
E 119—08a Test Methods for Fire Tests of Building Construction and Materials 703.2,703.2.1,703.2.3,703.3,703.4,
703.6,704.12,705.7,705.8.5,711.3.2,714.3.1,
714.4.1.1,715.1,716.2, Table716.3,716.5.6,716.5.8.1.1, Table 716.6,716.6.7.1,717.5.2,717.5.3,717.6.1,716.6.2.1, Table721.1(1),1409.10.2,2103.2,2603.5.1
E 136—09 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 703.5.1
E 330—02 Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference 1409.10.2,1710.5.2
E 331—00 (2009) Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference 1403.2
E 492—09 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling Assemblies Using the Tapping Machine 1207.3
E 605—93 (2006) Test Method for Thickness and Density of Sprayed Fire-resistive Material (SFRM) Applied to Structural Members 1705.13.4.1,1705.13.4.2
E 681—04 Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases 202
E 736—00 (2006) Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to Structural Members 704.13.2,1705.13.6
E 814—08b Test Method of Fire Tests of Through-penetration Firestops 202,714.3.1.2,714.3.2,7143.4.1.1.2
E 970—08a Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source 720.3.1
E 1300—07e01 Practice for Determining Load Resistance of Glass in Buildings 2404.1,2404.2,2404.3.1,2404.3.2,2404.3.3,2404.3.4,2404.3.5
E 1354—09 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter 424.2
E 1592—05 Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference 1504.3.2
E 1602—03 Guide for Construction of Solid Fuel-burning Masonry Heaters 2112.2
E 1886—05 Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missiles and Exposed to Cyclic Pressure Differentials 1609.1.2
E 1966—07 Test Method for Fire-resistant Joint Systems 202,715.3
E 1996—09 Specification for Performance of Exterior Windows, Glazed Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes 1609.1.2,1609.1.2.2
E 2072—04 Standard Specification for Photoluminescent (Phosphorescent) Safety Markings 1024.4
E 2174—09 Standard Practice for On-Site Inspection of Installed Fire Stops 1705.16.1
E 2273—03 Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies 1408.4.1
E 2307—04e01 Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Intermediate-scale, Multistory Test Apparatus 715.4
E 2393—09 Standard Practice for On-Site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barrier 1705.16.2
E 2404—08 Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics 803.1.4
E 2568—09e1 Standard Specification for PB Exterior Insulation and Finish Systems (EIFS) 1408.2
E 2570—07 Standard Test Method for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) for EIFS with Drainage 1408.4.1.1,1705.15.1
E 2573—07a Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics 803.13
E 2599—09 Standard Practice for Specimen Preparation and Mounting of Reflective Insulation Materials and Radiant Barrier Materials for Building Applications to Assess Surface Burning Characteristics 2613.3
E 2634—08 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems 1903.3
F 547—06 Terminology of Nails for Use with Wood and Wood-based Materials Table 2506.2
F 1346—91 (2003) Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs 3109.4,3109.4.1.8
F 1667—05 Specification for Driven Fasteners: Nails, Spikes and Staples Table 721.1(2), Table 721.1(3),1507.2.6,2303.6, Table2506.2
F 2006—00 (2005) 10 Standard/Safety Specification for Window Fall Prevention Devices with Emergency Escape (Egress) and Rescue (Ingress) Windows 1013.8
F 2090—08 Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms 1013.8,1013.8.1
F 2200—05 Standard Specification for Automated Vehicular Gate Construction 3110.3
G 152—06 Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6
G 154—06 Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials 1504.6
G 155—05a Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6
AWCIAssociation of the Wall and Ceiling Industry
513 West Broad Street, Suite 210
Falls Church, VA 22046
Standard
reference
number
TitleReferenced
in code
section number
12-B—98Technical Manual 12-B Standard Practice for the Testing and Inspection of Field Applied Thin Film Intumescent Fire-resistive Materials; an Annotated Guide, First Edition1705.14
AWPAAmerican Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
Standard
reference
number
TitleReferenced
in code
section number
C1—03All Timber Products-Preservative Treatment by Pressure Processes1505.6
M4—08Standard for the Care of Preservative-treated Wood Products1810.3.2.4.1, 2303.1.8
U1—11USE CATEGORY SYSTEM: User Specification for Treated Wood Except Section 6, Commodity Specification H1403.6, Table 1507.9.6, 1807.1.4, 1807.3.1, 1809.12, 1810.3.2.4.1, 2303.1.8, 2303.1.8.1,
2304.11.2, 2304.11.4, 2304.11.6, 2304.11.7
AWSAmerican Welding Society
550 N.W. LeJeune Road
Miami, FL 33126
Standard
reference
number
TitleReferenced
in code
section number
D1.3—98Structural Welding Code-Sheet Steel Table 1705.2.2, 1705.2.2.1.1
D1.4—98Structural Welding Code-Reinforcing Steel Table 1705.2.2, 1705.2.2.1.2, Table 1705.3, 2107.4
BHMABuilders Hardware Manufacturers’ Association
355 Lexington Avenue, 17th Floor
New York, NY 10017-6603
Standard
reference
number
TitleReferenced
in code
section number
A 156.10—2011Power Operated Pedestrian Doors1008.1.4.2
A 156.19—2007Standard for Power Assist and Low Energy Operated Doors1008.1.4.2
CGSBCanadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
Standard
reference
number
TitleReferenced
in code
section number
37-GP-52M (1984)Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric1504.7, 1507.12.2
37-GP-56M (1980)Membrane, Modified, Bituminous, Prefabricated and Reinforced for Roofing—with December 1985 Amendment1507.11.2
CAN/CGSB 37.54—95Polyvinyl Chloride Roofing and Waterproofing Membrane1507.13.2
CPAComposite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
Standard
reference
number
TitleReferenced
in code
section number
ANSI A135.4—2004Basic Hardboard 1404.3.1, 2303.1.6
ANSI A135.5—2004Prefinished Hardboard Paneling2303.1.6, 2304.6.2
ANSI A135.6—2006Hardboard Siding1404.3.2, 2303.1.6
CPSCConsumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
Standard
reference
number
TitleReferenced
in code
section number
16 CFR Part 1201 (2002)Safety Standard for Architectural Glazing Material2406.2, Table 2406.2(1), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1,
2408.3, 2409.1, 2409.2, 2409.3.1
16 CFR Part 1209 (2002)Interim Safety Standard for Cellulose Insulation720.6
16 CFR Part 1404 (2002)Cellulose Insulation720.6
16 CFR Part 1500 (2009)Hazardous Substances and Articles; Administration and Enforcement Regulations202
16 CFR Part 1500.44 (2009)Method for Determining Extremely Flammable and Flammable Solids202
16 CFR Part 1507 (2002)Fireworks Devices202
16 CFR Part 1630 (2007)Standard for the Surface Flammability of Carpets and Rugs804.4.1
CSACanadian Standards Association
5060 Spectrum Way
Mississauga, Ontario Canada L4W 5N6
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
Specifications for Windows, Doors and Unit Skylights 1710.5.1, 2405.5
CSSBCedar Shake and Shingle Bureau
P. O. Box 1178
Sumas, WA 98295-1178
Standard
reference
number
Title Referenced
in code
section number
CSSB—97 Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau Table 1507.8.5, Table 1507.9.6
DASMADoor and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
Standard
reference
number
TitleReferenced
in code
section number
ANSI/DASMA 107—1997 (R2004)Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation 2603.4.1.9
108—05Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference 1710.5.2
115—05Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure 1609.1.2.3
DOCU.S. Department of Commerce
National Institute of Standards and Technology
1401 Constitution Avenue NW
Washington, DC 20230
Standard
reference
number
TitleReferenced
in code
section number
PS-1—09Structural Plywood2303.1.4, 2304.6.2, Table 2304.7(4), Table 2304.7(5), Table 2306.2(1), Table 2306.2(2)
PS-2—10Performance Standard for Wood-based Structural-use Panels2303.1.4, 2304.6.2, Table 2304.7(5), Table 2306.2(1), Table 2306.2(2)
PS 20—05American Softwood Lumber Standard202, 1810.3.2.4, 2303.1.1
DOJU.S. Department of Justice
950 Pennsylvania Avenue, NW
Civil Rights Division, Disability Rights Section-NYA
Washington, DC 20530
Standard
reference
number
TitleReferenced
in code
section number
DOJ 36 CFR Part 1192American with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles (ADAAG) Department of Justice, 1991E109.2.4
DOLU.S. Department of Labor
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
29 CFR
Part 1910.1000 (2009)
Air Contaminants 202
DOTnU.S. Department of Transportation
c/o Superintendent of Documents
1200 New Jersey Avenue, SE
Washington, DC 20402-9325
Standard
reference
number
TitleReferenced
in code
section number
49 CFR Parts 100—185 2005Hazardous Materials Regulations202
49 CFR Parts 173.137 (2009)Shippers—General Requirements for Shipments and Packaging—Class 8—Assignment of Packing Group202
49 CFR—1998Specification of Transportation of Explosive and Other Dangerous Articles, UN 0335, UN 0336 Shipping Containers202
ENEuropean Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
Standard
reference
number
TitleReferenced
in code
section number
EN 1081—98Resilient Floor Coverings—Determination of the Electrical Resistance406.7.1
FEMAFederal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington, DC 20472
Standard
reference
number
TitleReferenced
in code
section number
FIA-TB-11—01Crawlspace Construction for Buildings Located in Special Flood Hazard Areas1805.1.2.1
P646—08Guidelines for Design for Structures for Vertical Evacuation from TsunamisM101.4
FMFactory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnston, RI 02919
Standard
reference
number
TitleReferenced
in code
section number
4450 (1989)Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 19921508.1, 2603.3, 2603.4.1.5
4470 (1992)Approval Standard for Class 1 Roof Covers1504.7
4474 (04)Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures1504.3.1
4880 (2005)American National Standard for Evaluating Insulated Wall or Wall and Roof/Ceiling Assemblies, Plastic Interior Finish Materials, Plastic Exterior Building Panels, Wall/Ceiling Coating Systems,Interior and Exterior Finish Systems2603.4, 2603.10
GAGypsum Association
810 First Street N.E. #510
Washington, DC 20002-4268
Standard
reference
number
TitleReferenced
in code
section number
GA 216—07Application and Finishing of Gypsum Panel ProductsTable 2508.1, 2509.2
GA 600—09Fire-Resistance Design Manual, 18th EditionTable 721.1(1), Table 721.1(2), Table 721.1(3)
HPVAHardwood Plywood Veneer Association
1825 Michael Faraday Drive
Reston, VA 20190
Standard
reference
number
Title Referenced
in code
section number
HP-1—2009 Standard for Hardwood and Decorative Plywood 2303.3, 2304.6.2
HUDU.S. Department of Housing and Urban Development
451 7th Street, SW
Washington, DC 20410
Standard
reference
number
Title Referenced
in code
section number
HUD 24 CFR Part 3280 (2008) Manufactured Home Construction and Safety Standards G201
ICCInternational Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
TitleReferenced
in code
section number
ICC A117.1—09Accessible and Usable Buildings and Facilities202, 907.5.2.3.4, 1007.9, 1010.1, 1010.7.5, 1010.10, 1011.4, 1022.9, 1101.2, 1107.2, 1109.1,
1109.2, 1109.5.1, 1109.5.2, 1110.3, 1110.4, 1110.4.2, 3008.7.7.1,
3008.7.7.2, 3411.8.2, 3411.8.3, E101.2, E104.2, E104.2.1, E104.3.4,
E106.4.9, E107.3, E108.3, E108.4, E109.2.2.2, E109.2.2.3,
E109.2.3, E109.2.5, E110.2
ICC 300—12ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands1028.1.1, 1028.14.2, Table 1607.1, 3401.1
ICC 400—12Standard on Design and Construction of Log Structures2301.2
ICC 500—08ICC/NSSA Standard on the Design and Construction of Storm Shelters202, 423.1
ICC 600—08Standard for Residential Construction in High-wind Regions1609.1.1, 1609.1.1.1, 2308.2.1
IEBC—12International Existing Building Code®3401.5
IECC—12International Energy Conservation Code®101.4.6, 201.3, 1203.1, 1203.3.2, 1301.1.1, 1405.3, 3401.3
IFC—12International Fire Code®101.4.5, 102.6, 201.3, 202, 307.1, Table 307.1(1), Table 307.1(2), 307.1.1, 403.4.5, 404.2, 406.7, 406.8, 410.3.6, 411.1, 412.1, 412.6.1,
413.1, 414.1.1, 414.1.2, 414.1.2.1, 414.2, 414.2.5, Table 414.2.5(1),
Table 414.2.5(2), 414.3, 414.5, 414.5.1, Table 414.5.1, 414.5.2, 414.5.3, 414.5.4, 414.6,
415.1, 415.5, 415.5.1, 415.5.1.1, 415.5.1.4, Table 415.5.2, 415.7.3, 415.8,
415.8.1, 415.8.1.4, 415.8.2, 415.8.2.3, 415.8.2.4, 415.8.2.6, 415.8.2.7, 415.8.2.8,
415.8.3, 415.8.4, 415.9, 415.10, 415.10.1.7, 415.10.4, 415.10.7.2, 415.10.9.3,
415.10.10.1, 416.1, 416.4, 421.1, 421.7, 507.3, 507.8.1.1.1, 507.8.1.1.2,
507.8.1.1.3, 705.8.1, 707.1, 901.2, 901.3, 901.5, 901.6.2, 901.6.3, 903.1.1,
903.2.7.1, 903.2.11.6, 903.2.12, 903.5, 904.2.1, 905.1, 905.3.6, 906.1, 907.1.8,
907.2.5, 907.2.13.2, 907.2.15, 907.2.16, 907.6.5, 907.8, 909.20, 910.2.2, 1001.3,
1001.4, 1008.1.9.6, 1203.4.2, 1203.5, 1507.16, 1511.1, Table 1604.5, 2603.4.1.12,
2702.1, 2702.2.9, 2702.2.11, 2702.2.12, 2702.2.13, 2702.3, 3003.3, 3008.1.2, 3102.1,
3103.1, 3111.1, 3302.3, 3303.7, 3309.2, 3401.3, 3403.5, 3404.6, 3412.3.2, 3412.6.8.1,
3412.6.14, 3412.6.14.1
IFGC—12International Fuel Gas Code®101.4.1, 201.3, Table 307.1(1), 415.8.3, 2113.11.1.2, 2113.15, 2801.1, 3401.3, A101.2
IMC—12International Mechanical Code®101.4.2, 201.3, 307.1, Table 307.1(1), 406.6.2, 406.8.2, 406.8.4, 409.3, 412.6.6, 414.1.2, 414.3, 415.8.1.4, 415.8.2, 415.8.2.7, 415.8.3, 415.8.4, 415.10.11
415.10.11.1, 416.2.2, 413.3, 416.3, 417.1, 419.8, 421.5, 603.1, 603.1.1, 603.1.2, 712.1.5,
717.2.2, 717.5.3, 717.5.4, 717.6.1, 717.6.2, 717.6.3, 718.5, 720.1, 720.7,
903.2.11.4, 904.2.1, 904.11, 907.3.1, 908.6, 909.1, 909.10.2, 909.13.1, 1015.5,
1018.5, 1203.1, 1203.2.1, 1203.4.2, 1203.4.2.1, 1203.5, 1209.3, 2304.5,
2801.1, 3004.3.1, 3401.3, 3412.6.7.1, 3412.6.8, 3412.6.8.1
IPC—12 International Plumbing Code®101.4.3, 201.3, 415.8.4, 603.1.2, 718.5, 903.3.5, 912.5, 1206.3.3, 1503.4, 1503.4.1, 1805.4.3, 2901.1, Table 2902.1, 3305.1, 3401.3, A101.2
IPMC—12 International Property Maintenance Code®101.4.4, 102.6, 103.3, 3401.3, 3412.3.2
IPSDC—12 International Private Sewage Disposal Code®101.4.3, 2901.1, 3401.3
IRC—12 International Residential Code®101.2, 305.2.3, 308.3.1, 308.4.1, 308.6.4, 310.1, 310.5.1, 2308.1, 3401.3
IWUIC—12 International Wildland-Urban Interface Code®Table 1505.1
SBCCI SSTD 11—97 Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles 1711.2.1, 1711.2.2
ISOInternational Organization for Standardization
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case Postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
Title Referenced
in code
section number
ISO 8115—86 Cotton Bales—Dimensions and Density Table 307.1(1), Table 415.10.1.1.1
NAAMMNational Association of Architectural Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312
Glen Ellyn, IL 60137
Standard
reference
number
Title Referenced
in code
section number
FP 1001—07Guide Specifications for Design of Metal Flag Poles 1609.1.1
NCMANational Concrete Masonry Association
13750 Sunrise Valley
Herndon, VA 22071-4662
Standard
reference
number
TitleReferenced
in code
section number
TEK 5—84 (1996)Details for Concrete Masonry Fire WallsTable 721.1(2)
NFPANational Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Standard
reference
number— year of publication
TitleReferenced
in code
section number
02-11Hydrogen Technologies Code101.4.1
10—10Portable Fire Extinguishers906.2, 906.3.2, 906.3.4, Table 906.3(1), Table 906.3(2)
11—10Low Expansion Foam904.7
12—11Carbon Dioxide Extinguishing Systems904.8, 904.11
12A—09 Halon 1301Halon 1301 Fire Extinguishing Systems904.9
13—10 Installation of Sprinkler Systems708.2, 903.3.1.1, 903.3.2, 903.3.5.1.1, 903.3.5.2, 904.11, 905.3.4, 907.6.3, 1009.3
13D—10Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes903.3.1.3, 903.3.5.1.1
13R—10Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height903.3.1.2, 903.3.5.1.1, 903.3.5.1.2, 903.4
14—10Installation of Standpipe and Hose System905.2, 905.3.4, 905.4.2, 905.6.2, 905.8
16—11Installation of Foam-water Sprinkler and Foam-water Spray Systems904.7, 904.11
17—09Dry Chemical Extinguishing Systems904.6, 904.11
17A—09Wet Chemical Extinguishing Systems904.5, 904.11
20—10Installation of Stationary Pumps for Fire Protection913.1, 913.2.1, 913.5
30—12Flammable and Combustible Liquids Code415.5, 507.8.1.1.1, 507.8.1.1.2
31—11Installation of Oil-burning Equipment2113.15
32—11Dry Cleaning Plants415.8.4
40—11Storage and Handling of Cellulose Nitrate Film409.1
54-12National Fuel Gas Code101.4.1
58—11Liquefied Petroleum Gas Code415.8.3
61—08Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities415.8.1
70—1114National Electrical Code108.3, 415.10.1.8, 904.3.1, 907.6.1, 909.12.1, 909.16.3, 1205.4.1, 2701.1, 3401.3, H106.1, H106.2, K101, K111.1
72—10National Fire Alarm Code901.6, 903.4.1, 904.3.5, 907.2, 907.2.5, 907.2.11, 907.2.13.2, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.2.2, 907.6, 907.6.1, 907.6.5, 907.7, 907.7.1, 907.7.2, 907.2.9.2, 911.1.5, 3006.5, 3007.8
80—10Fire Doors and Other Opening Protectives410.3.5, 509.4.2, 716.5, 716.5.7, 716.5.8.1, 716.5.9.2, 716.6, 716.6.4, 1008.1.4.2, 1008.1.4.3
82—09Standard for Incinerators and Waste and Linen Handling Systems and Equipment, 2009 Edition713.13
85—11Boiler and Combustion System Hazards Code (Note: NFPA 8503 has been incorporated into NFPA 85)415.8.1
92B—09Smoke Management Systems in Malls, Atria and Large Spaces909.8
99—0512Standard for Health Care Facilities407.10
101—12Life Safety Code1028.6.2
102-16Grandstands, Folding and Telescopic Seating, Tents, and Membrane Structures3103.5
105—10Standard for the Installation of Smoke Door Assemblies405.4.2, 710.5.2.2, 716.5.3.1, 909.20.4.1
110—10Emergency and Standby Power Systems2702.1
111—10Stored Electrical Energy Emergency and Standby Power Systems2702.1
120—10Coal Preparation Plants415.8.1
170—09Standard for Fire Safety and Emergency Symbols1024.2.6.1
211—10Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances2112.5
221—09Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls, 2009 Edition706.2
252—03Standard Methods of Fire Tests of Door Assemblies715.4.2, 715.4.3, 715.4.7.3.1, Table 716.3, 716.4, 716.5.1, 716.5.3, 716.5.8, 716.5.8.1.1, 716.5.8.3.1
253—11Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source406.8.3, 424.2, 804.2, 804.3
257—07Standard for Fire Test for Window and Glass Block AssembliesTable 716.3, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.7.3
259—08Test Method for Potential Heat of Building Materials2603.4.1.10, 2603.5.3
265—11Method of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings on Full Height Panels and Walls803.1.3, 803.1.3.1
268—12Standard Test Method for Determining Ignitibility of Exterior Wall Assemblies Using a Radiant Heat Energy Source1406.2.1.1, 1406.2.1.1.1, 1406.2.1.1.2, 2603.5.7, D105.1
275—09Standard Method Of Fire Tests for the Evaluation of Thermal
Barriers Used Over Foam Plastic Insulation
1407.10.2, 2603.4
285—06Standard Method of Test for the Evaluation of Flammability Characteristics of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components718.2.6, 1403.5, 1407.10.4, 1409.10.4, 1509.6.2, 2603.5.5
286—11Standard Method of Fire Test for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth402.6.4.4, 803.1.2, 803.1.2.1, 803.9, 2603.4, 2603.7, 2603.10, 2604.2.4, 2613.4
288—12Standard Method of Fire Tests of Floor Fire Door Assemblies Installed Horizontally in Fire-resistance-rated Floor Systems711.8
289—09Standard Method of Fire Test for Individual Fuel Packages402.6.2, 407.6.4.6, 424.2
409—11Aircraft Hangers412.4.6, Table 412.4.6, 412.4.6.1, 412.6.5
418—11Standard for Heliports412.7.4
484—12Combustible Metals415.8.1
654—06Prevention of Fire & Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids415.8.1
655—12Prevention of Sulfur Fires and Explosions415.8.1
664—12Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities415.8.1
701—10Standard Methods of Fire Tests for Flame-propagation of Textiles and Films410.3.6, 424.2, 801.4, 806.1, 806.1.2, 806.2, 3102.3, 3102.3.1, 3102.6.1.1, 3105.4, D102.2.8, H106.1.1
704—12 Standard System for the Identification of the Hazards of Materials for Emergency Response202, 414.7.2
720—0912Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment908.7
1124—06Manufacture, Transportation and Storage of Fireworks and Pyrotechnic Articles415.5.1.1, 415.3.1
2001—1112Clean Agent Fire Extinguishing Systems904.10
PCIPrecast Prestressed Concrete Institute
200 West Adams Street, Suite 2100
Chicago, IL 60606-5230
Standard
reference
number
TitleReferenced
in code
section number
MNL 124—89Design for Fire Resistance of Precast Prestressed Concrete722.2.3.1
MNL 128—01Recommended Practice for Glass Fiber Reinforced Concrete Panels1903.2
PTIPost-Tensioning Institute
8601 North Black Canyon Highway, Suite 103
Phoenix, AZ 85021
Standard
reference
number
Title Referenced
in code
section number
PTI—2007Standard Requirements for Analysis of Shallow Concrete Foundations on Expansive Soils, Third Edition1808.6.2
PTI—2007Standard Requirements for Design of Shallow Post-tensioned Concrete Foundation on Expansive Soils, Second Edition1808.6.2
RMIRack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte, NC 28217
Standard
reference
number
TitleReferenced
in code
section number
ANSI/MH16.1—08Specification for Design, Testing and Utilization of Industrial Steel Storage Racks2209.1
SDISteel Deck Institute
P. O. Box 25
Fox River Grove, IL 60021
Standard
reference
number
TitleReferenced
in code
section number
ANSI/NC1.0—10Standard for Noncomposite Steel Floor Deck2210.1.1.1
ANSI/RD1.0—10Standard for Steel Roof Deck2210.1.1.2
SJISteel Joist Institute
1173B London Links Drive
Forest, VA 24551
Standard
reference
number
TitleReferenced
in code
section number
CJ—10Standard Specification for Composite Steel Joists, CJ-series1604.3.3, 2203.2, 2207.1
JG—10Standard Specification for Joist Girders1604.3.3, 2203.2, 2207.1
K—10Standard Specification for Open Web Steel Joists, K-series1604.3.3, 2203.2, 2207.1
LH/DLH—10Standard Specification for Longspan Steel Joists, LH-series and Deep Longspan Steel Joists, DLH-series1604.3.3, 2203.2, 2207.1
SPRISingle-Ply Roofing Institute
411 Waverly Oaks Road, Suite 331B
Waltham, MA 02452
Standard
reference
number
TitleReferenced
in code
section number
ANSI/SPRI/ FM4435-ES-1—03Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems1504.5
RP-4—08Wind Design Guide for Ballasted Single-ply Roofing Systems1504.4
TIATelecommunications Industry Association
2500 Wilson Boulevard
Arlington, VA 22201-3834
Standard
reference
number
TitleReferenced
in code
section number
222-G—05Structural Standards for Antenna Supporting Structures and Antennas, including—Addendum 1, 222-G-1, Dated 2007 and Addendum 2, 222-G-2 Dated 20091609.1.1, 3108.1, 3108.2
TMSThe Masonry Society
3970 Broadway, Unit 201-D
Boulder, CO 80304-1135
Standard
reference
number
TitleReferenced
in code
section number
0216—97Standard Method for Determining Fire Resistance of Concrete and Masonry Construction AssembliesTable 721.1(2), 722.1
0302—07Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls1207.2.1
402—11Building Code Requirements for Masonry Structures1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4, 1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9 2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2103.9, 2103.12 2103.13, 2103.14, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.2, 2104.3, 2104.4, 2105.2.2.1, 2105.2.2.1.2, 2105.2.2.1.3, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4, 2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2109.3, 2110.1
403—10Direct Design Handbook for Masonry Structures2101.2.7
602—11Specification for Masonry Structures1405.6.1, 1705.4, 1807.1.6.3, 2103.9, 2103.12, 2103.13, 2103.14, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.2, 2104.3, 2104.4, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
TPITruss Plate Institute
218 N. Lee Street, Suite 312
Alexandria, VA 22314
Standard
reference
number
TitleReferenced
in code
section number
TPI 1—2007National Design Standards for Metal-plate-connected Wood Truss Construction2303.4.6, 2306.1
ULUnderwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
TitleReferenced
in code
section number
9—2009Fire Tests of Window Assemblies—with Revisions through April 2005715.5.2, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.8.1
10A—2009Tin Clad Fire Doors716.5
10B—2008Fire Tests of Door Assemblies—with Revisions through April 2009716.5.2
10C—2009Positive Pressure Fire Tests of Door Assemblies716.5.1, 716.5.3, 1008.1.10.1
14B—2008Sliding Hardware for Standard Horizontally-mounted Tin Clad Fire Doors716.5
14C—06Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs—with revisions through December 2008716.5
55A—04Materials for Built-Up Roof Coverings1507.10.2
103—01Factory-built Chimneys, for Residential Type and Building Heating Appliances—with Revisions through March 2010718.2.5.1
127—08Factory-built Fireplaces—with Revisions through January 2010718.2.5.1, 2111.11
199E—04Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers904.11.4.1
217—06Single and Multiple Station Smoke Alarms—with Revisions through April 2010907.2.11
263—03Standard for Fire Tests of Building Construction and Materials, with revisions through October 2007703.2, 703.2.1, 703.2.3, 703.3, 703.4, 703.6, 704.12, 705.7, 705.8.5, 707.7, 711.3.2, 714.3.1, 714.4.1.1, 715.1, 716.2, Table 716.3, 716.5.6, 716.5.8.1.1, 716.7.1, 717.5.2, 717.5.3, 717.6.2.1, Table 721.1(1), 1407.10.2, 2103.2, 2603.4, 2603.5.1
268—09Smoke Detectors for Fire Protective Signaling Systems—with Revisions through January 1999407.8, 907.2.6.2
294—1999Access Control System Units with revisions through 20091008.1.9.8
300—05Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment904.11
305—97Panic Hardware—with revisions through January 20071008.1.10.1
325—02Door, Drapery, Gate, Louver and Window Operations and Systems—with Revisions through February 2010405.3.5, 3110.4
555—2006Fire Dampers—with revisions through May 2010717.3
555C—2006Ceiling Dampers—with revisions through May 2010717.3
555S—99Smoke Dampers—with Revisions through May 2010717.3, 717.3.1
580—2006Test for Uplift Resistance of Roof Assemblies—with Revisions through July 20091504.3.1, 1504.3.2
641—95Type L Low-temperature Venting Systems—with Revisions through July 20092113.11.1.4
710B—04Recirculating Systems—with Revisions through December 2009904.11
723—2008Standard for Test for Surface Burning Characteristics of Building Materials202, 402.6.4.4, 406.7.2, 703.5.2, 720.1, 720.4, 803.1.1, 803.1.4, 803.9, 803.13, 806.5, 1404.12.1, 1407.9, 1407.10.1, 1409.9, 1409.10.1, 1509.6.2, 1509.6.3, 2303.2, 2603.3, 2603.4.1.13, 2606.3.5.4, 2603.7, 2604.2.4, 2606.4, 2613.3, 3105.4
790—04Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through October 20081505.1, 2603.6, 2610.2, 2610.3
793—08Standards for Automatically Operated Roof Vents for Smoke and Heat406.8.5.1.1, 910.3.1
864—03Standards for Control Units and Accessories for Fire Alarm Systems— with Revisions through February 2010909.12
924—06Standard for Safety Emergency Lighting and Power Equipment— with Revisions through January 20091011.5
1040—96Fire Test of Insulated Wall Construction— with Revisions through September 20071407.10.3, 1409.10.3, 2603.4, 2603.10
1256—02Fire Test of Roof Deck Construction—with Revisions through January 20071508.1, 2603.3, 2603.4.1.5
1479—03Fire Tests of Through-penetration Firestops—with Revisions through March 2010202, 714.3.1.2, 714.3.2, 714.4.1.1.2, 714.5
1482—2010Solid-Fuel-type Room Heater2112.2, 2112.5
1703—02Flat-Plate Photovoltaic Modules and Panels—with Revisions through April 20081507.17.1, 1509.7.4
1715—97Fire Test of Interior Finish Material—with Revisions through April 20081407.10.3, 1409.10.2, 1409.10.3, 2603.4, 2603.10, 2613.4
1777—2007Chimney Liners—with Revisions through July 20092113.11.1, 2113.19
1784—01Air Leakage Tests of Door Assemblies—with Revisions through July 2009710.5.2.2, 713.14.1, 716.5.3.1, 716.5.7.1, 716.5.7.3, 3007.7.3, 3008.7.3
1897—04Uplift Tests for Roof Covering Systems—with Revisions through May 20081504.3.1
1975—06Fire Test of Foamed Plastics Used for Decorative Purposes402.6.2, 402.6.4.5, 424.2
1994—04Luminous Egress Path Marking Systems—with Revisions through April 2010411.7, 1024.2.1, 1024.2.3, 1024.2.4, 1024.4
2017—2008Standards for General-purpose Signaling Devices and Systems— with Revisions through October 2009406.8.5.1.1, 3109.4.1.8
2034—2008Standard for Single- and Multiple Station Carbon Monoxide Alarm—with Revisions through February 2009908.7
2075—04Standard for Gas and Vapor Detectors and Sensors—
with Revisions through September 28, 2007
406.8.5.1.1, 908.7.1
2079—04Tests for Fire Resistance of Building Joint Systems— with Revisions through June 2008202, 715.3, 715.6
2200—98Stationary Engine Generator Assemblies— with Revisions through December 20092702.1.1
ULCUnderwriters Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada M1R3B4
Standard
reference
number
TitleReferenced
in code
section number
CAN/ULC S 102.2—1988Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings and Miscellaneous Materials and Assemblies—with 2000 Revisions720.4
USCUnited States Code
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
18 USC Part 1, Ch.40Importation, Manufacture, Distribution and Storage of Explosive Materials202
WDMAWindow and Door Manufacturers Association
1400 East Touhy Avenue #470
Des Plaines, IL 60018
Standard
reference
number
TitleReferenced
in code
section number
AAMA/WDMA/CSA 101/I.S.2/A440—11Specifications for Windows, Doors and Unit Skylights1710.5.1, 2405.5
WRIWire Reinforcement Institute, Inc.
942 Main Street, Suite 300
Hartford, CT 06103
Standard
reference
number
TitleReferenced
in code
section number
WRI/CRSI—81Design of Slab-on-ground Foundations—with 1996 Update1808.6.2
Resources
Help us
keep law free