About this chapter: This code contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials and methods of construction. This chapter contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard.

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken, PA 19428-2959

D2898—2010(2017)

Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing

503.2

D3909/D3909M—14

Standard Specification for Asphalt Roll Roofing (Glass Felt) Surfaced With Mineral Granules

504.2, 504.2.1, 505.2, 505.2.1, 506.2, 506.2.1

D6662—2017

Standard Specification for Polyolefin-Based Plastic Lumber Decking Boards

503.2

D7032—2017

Standard Specification for Establishing Performance Ratings for Wood-Plastic Composite and Plastic Lumber Deck Boards, Stair Treads, Guards, and Handrails

503.2

E84—2018b

Standard Test Method for Surface Burning Characteristics of Building Materials

202, 503.2

E108—2017

Standard Test Methods for Fire Tests of Roof Coverings

504.2, 505.2, 506.2

E119—2018b

Standard Test Methods for Fire Tests of Building Construction and Materials

501.3

E136—2019

Standard Test Method for Assessing Combustibility of Materials Using a Vertical Tube Furnace at 750°C

202

E2768—2011(2018)

Standard Test Method for Extended Duration Surface Burning Characteristics of Building Materials (30 min Tunnel Test)

503.2

ICC

International Code Council, Inc.
500 New Jersey Ave, NW
Washington, DC 20001

UL

UL LLC
333 Pfingsten Road
Northbrook, IL 60062-2096

263—2011

Standard for Fire Tests of Building Construction and Materials—with Revisions through March 2018

501.3

723—2018

Standard for Test for Surface Burning Characteristics of Building Materials

202, 503.2

790—2004

Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through October 2018

504.2, 505.2, 506.2