Heads up: There are no amended sections in this chapter.

User note:

About this chapter: This code contains numerous references to standards that are used to provide requirements for materials and methods of construction. This chapter contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard. This chapter lists the standards that are referenced in various sections of this document.

The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ACCA

Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206

ANSI/ACCA 1 Manual D—2016

Residential Duct Systems

601.4, 603.2

ANSI/ACCA 10 Manual SPS—2010 RA 2017

HVAC Design for Swimming Pools and Spas

403.2.1

ANSI/ASHRAE/ACCA 183—2007 (reaffirmed 2014)

Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings

312.1

AHRI

Air-Conditioning, Heating & Refrigeration Institute
2311 Wilson Blvd., Suite 400
Arlington, VA 22201

700—2017

with Addendum 1: Specifications for Refrigerants

1102.2.2.3

AMCA

Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004

230—15

Laboratory Methods of Testing Air Circulating Fans for Rating and Certification

930.1

ANSI/AMCA 210—16/ANSI/ASHRAE 51—16

Laboratory Methods of Testing Fans for Aerodynamic Performance Rating

403.3.2.5

ANSI/AMCA 550—09 (Rev. 09/18)

Test Method for High Velocity Wind Driven Rain Resistant Louvers

401.5, 501.3.2

ANSI

American National Standards Institute
25 West 43rd Street, 4th Floor
New York, NY 10036

Z21.1/CSA 1.1—2016

Household Cooking Gas Appliances

505.2

Z21.8—1994 (R2012)

Installation of Domestic Gas Conversion Burners

919.1

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta, GA 30329

15—2019

Safety Standard for Refrigeration Systems

1101.6, 1105.8, 1108.1

34—2019

Designation and Safety Classification of Refrigerants

202, 1102.2.1, 1103.1

62.1—2019

Ventilation for Acceptable Indoor Air Quality

401.2, 403.3.1.1.2.3.2

90.1—2016

Energy Standard for Buildings Except Low-rise Residential Buildings

401.2

170—2017

Ventilation of Health Care Facilities

407

180—2018

Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems

102.3

ANSI/AMCA 210—ANSI/ASHRAE 51—16

Laboratory Methods of Testing Fans for Aerodynamic Performance Rating

403.3.2.4

ASHRAE—2021

ASHRAE Fundamentals Handbook

603.2

ASME

American Society of Mechanical Engineers
Two Park Avenue
New York, NY 10016-5990

A112.4.1—2009 (R2019)

Water Heater Relief Valve Drain Tubes

1006.6

B1.1—2003

Unified Inch Screw Threads, UN and UNR Thread Form

1108.3.4

B1.13M—2006

Metric Screw Threads: M Profile

1108.3.4

B1.20.1—2019

Pipe Threads, General Purpose (Inch)

1203.3.5, 1303.3.3

B1.20.3—1976

Dryseal Pipe Threads, Inch

1108.3.4

B16.3—2021

Malleable Iron Threaded Fittings, Classes 150 & 300

Table 1202.5

B16.5—2019

Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24

Table 1202.5

B16.9—2019

Factory-made Wrought Steel Buttwelding Fittings

Table 1202.5

B16.11—2021

Forged Fittings, Socket-welding and Threaded

Table 1202.5

B16.15—2018

Cast Alloy Threaded Fittings: Classes 125 and 250

Table 1202.5

B16.18—2018

Cast Copper Alloy Solder Joint Pressure Fittings

513.13.1, Table 1202.5

B16.22—2018

Wrought Copper and Copper Alloy Solder Joint Pressure Fittings

513.13.1, Table 1202.5

B16.24—2021

Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900, 1500 and 2500

Table 1202.5

B16.26—2018

Cast Copper Alloy Fittings for Flared Copper Tubes

Table 1202.5

B16.28—1994

Wrought Steel Buttwelding Short Radius Elbows and Returns

Table 1202.5

B16.50—2018

Wrought Copper and Copper Alloy Braze-joint Pressure Fittings

Table 1107.5

B16.51—2018

Copper and Copper Alloy Press-connect Pressure Fittings

Table 1202.5

B31.5—2019

Refrigeration Piping and Heat Transfer Components

1107.1

B31.9—2020

Building Services Piping

1201.3

BPVC—2019

ASME Boiler & Pressure Vessel Code—07 Edition

1003.1, 1004.1, 1009.2, 1011.1

CSD-1—2021

Controls and Safety Devices for Automatically Fired Boilers

1004.1

ASSE

ASSE International
18927 Hickory Creek Drive, Suite 220
Mokena, IL 60448

1017—2009

Performance Requirements for Temperature Actuated Mixing Values for Hot Water Distribution Systems

1002.2.2

1061—2015

Performance Requirements for Push Fit Fittings

Table 1202.5

1079—2005

Performance Requirements for Dielectric Pipe Unions

1108.1.1

ASSP

American Society of Safety Professionals
520 N. Northwest Highway
Park Ridge, IL 60068

ANSI/ASSP Z359.1—2019

The Fall Protection Code

304.11

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken, PA 19428

A53/A53M—2018

Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated, Welded and Seamless

Table 1202.4, Table 1202.5, Table 1302.3

A105/A105M—18

Standard Specification for Carbon Steel Forgings for Piping Applications

Table 1107.5

A106/A106M—2018

Specification for Seamless Carbon Steel Pipe for High-temperature Service

Table 1202.4, Table 1202.5, Table 1302.3

A126—04(2014)

Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings

Table 1202.5

A181/A181M—14

Standard Specification for Carbon Steel Forgings, for General-purpose Piping

Table 1107.5

A193/A193M—19

Standard Specification for Alloy-steel and Stainless Steel Bolting for High Temperature or High Pressure Service and Other Special Purpose Applications

Table 1107.5

A234/A234M—18A

Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service

Table 1202.5

A240/A240M—17

Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications

Table 1302.3

A254—2010(2018)

Specification for Copper Brazed Steel Tubing

Table 1202.4, Table 1302.3

A269—15

Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service

Table 1302.3

A312—17

Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes

Table 1302.3

A334/A334M—04a(2016)

Standard Specification for Seamless and Welded Carbon and Alloy-steel Tubes for Low-temperature Service

Table 1107.4

A395/A395M—99(2014)

Standard Specification for Ferritic Ductile Iron Pressure-retaining Castings for Use at Elevated Temperatures

Table 1202.5, Table 1302.3

A420/A420M—2016

Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Low-temperature Service

Table 1202.5

A536—84(2014)

Standard Specification for Ductile Iron Castings

Table 1202.5

A539—99

Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines

Table 1302.3

A707/A707M—19

Standard Specification for Forged Carbon and Alloy Steel Flanges for Low-temperature Service

Table 1107.5

B32—08(2014)

Specification for Solder Metal

1203.3.3

B42—15a

Specification for Seamless Copper Pipe, Standard Sizes

513.13.1, Table 1107.4, Table 1202.4, Table 1302.3

B43—15

Specification for Seamless Red Brass Pipe, Standard Sizes

513.13.1, Table 1107.4, Table 1202.4, Table 1302.3

B68/B68M—11

Specification for Seamless Copper Tube, Bright Annealed

513.13.1

B75/B75M—11

Specification for Seamless Copper Tube

Table 1302.3

B88—2016

Specification for Seamless Copper Water Tube

513.13.1, Table 1107.4, Table 1202.4, Table 1302.3

B135/B135M—17

Specification for Seamless Brass Tube

Table 1202.4

B210/B210M—19a

Standard Specification for Aluminum and Aluminum-alloy Drawn Seamless Tubes

Table 1107.4

B251/B251M—2017

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

513.13.1, Table 1202.4

B280—2018

Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

513.13.1, Table 1107.4, Table 1302.3

B302—2017

Specification for Threadless Copper Pipe, Standard Sizes

Table 1202.4, Table 1302.3

B361—16

Standard Specification for Factory-made Wrought Aluminum and Aluminum-alloy Welding Fittings

Table 1107.5

B491/B491M—15

Standard Specification for Aluminum and Aluminum-alloy Extruded Round Tubes for General-purpose Applications

Table 1107.4

B813—2016

Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube

1203.3.3

B819—2018

Standard Specification for Seamless Copper Tube for Medical Gas Systems

Table 1107.4

B828—2016

Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings

1203.3.3

B1003—16

Standard Specification for Seamless Copper Tube for Linesets

Table 1107.4

C315—2007(2016)

Specification for Clay Flue Liners and Chimney Pots

801.16.1, Table 803.10.4

C411—2017

Test Method for Hot-surface Performance of High-temperature Thermal Insulation

604.3

D56—2016A

Test Method for Flash Point by Tag Closed Cup Tester

202

D93—18

Test Method for Flash Point of Pensky-Martens Closed Cup Tester

202

D1527—99(2005)

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80

Table 1202.4

D1693—15

Test Method for Environmental Stress-cracking of Ethylene Plastics

Table 1202.4

D1785—15E1

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120

Table 1202.4, Table 1210.4

D2235—2004(2016)

Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings

1203.3.4

D2241—15

Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)

Table 1202.4, Table 1210.4

D2282—99(2005)

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)

Table 1202.4

D2412—11(2018)

Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading

603.8.3

D2464—15

Standard Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table 1210.5

D2466—2017

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40

Table 1202.5, Table 1210.5

D2467—15

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table 1202.5, Table 1210.5

D2564—2012(2018)

Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems

1203.3.4

D2657—2007(2015)

Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings

Table 1210.5

D2683—14

Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing

Table 1210.5, 1210.6.6.1

D2737—12a

Standard Specification for Polyethylene (PE) Plastic Tubing

Table 1210.4

D2846/D2846M—2017BE1

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-water Distribution Systems

Table 1202.4, Table 1202.5, 1203.3.4, Table 1210.4

D2996—2017

Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe

Table 1302.3

D3035—15

Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter

Table 1210.4

D3261—2016

Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing

Table 1210.5, 1210.6.6.1

D3278—96(2011)

Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus

202

D3309—96a(2002)

Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution Systems

Table 1202.4

E84—2018B

Standard Test Method for Surface Burning Characteristics of Building Materials

202, 510.8, 602.2, 602.2.1, 602.2.1.6, 602.2.1.7, 604.3, 1204.1

E119—2018B

Test Method for Fire Tests of Building Construction and Materials

607.2.1, 607.5.2, 607.5.5, 607.6.1

E136—2019

Standard Test Method for Assessing Combustibility of Materials Using a Vertical Tube Furnace at 750 Degrees C

202

E814—2013A(2017)

Standard Test Method for Fire Tests of Penetration Firestop Systems

506.3.11.2, 506.3.11.3

E1509—2012(2017)

Specification for Room Heaters, Pellet Fuel-burning Type

904.1

E2231—2018

Standard Practice for Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics

604.3, 1204.1

E2336—16

Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems

506.3.6, 506.3.11.2

F437—15

Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 1210.5

F438—2017

Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40

Table 1202.5, Table 1210.5

F439—13

Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 1202.5, Table 1210.5

F441/F441M—15

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80

Table 1202.4, Table 1210.4

F442/F442M—13e1

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)

Table 1202.4, Table 1210.4

F493—14

Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings

1203.3.4

F714—13

Standard Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter

Table 1210.4

F876—2018A

Specification for Cross-linked Polyethylene (PEX) Tubing

Table 1202.4, Table 1210.4

F877—2018A

Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution Systems

Table 1202.4, Table 1202.5, Table 1210.4

F1055—2016A

Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Cross linked Polyethylene (PEX) Pipe and Tubing

Table 1210.5, 1210.6.6.2

F1281—2017

Specification for Cross-linked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe

Table 1202.4

F1282—2017

Standard Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe

Table 1202.4, Table 1210.4, Table 1210.5

F1476—07(2013)

Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications

Table 1202.5, 1203.3.7

F1548—2001(2018)

Standard Specification for the Performance of Fittings for Use with Gasketed Mechanical Couplings Used in Piping Applications

Table 1202.5

F1807—2018

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polethylene of Raised Temperature (PE-RT) Tubing

Table 1202.5, Table 1210.5

F1924—12

Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing

1210.6.6.3

F1960—2018

Specification for Cold-expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing

Table 1202.5

F1974—09(2005)

Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Poly ethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe

Table 1202.5

F2080—16

Specification for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe

Table 1202.5

F2098—2015

Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings

Table 1202.5

F2159—2018

Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing

Table 1202.5, Table 1210.5

F2389—2017A

Specification for Pressure-rated Polypropylene Piping Systems

Table 1202.4, Table 1202.5, 1203.16.1, Table 1210.4, Table 1210.5, 1210.6.7.1

F2434—14

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing

Table 1210.5

F2623—14

Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR9 Tubing

Table 1202.4, Table 1210.4

F2735—2009(2016)

Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing

Table 1202.5

F2769—2018

Polyethylene of Raised Temperature (PE-RT) Plastic Hot- and Cold-water Tubing and Distribution Systems

Table 1202.4, Table 1210.5

F2806—10(2015)

Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (Metric SDR-PR)

Table 1202.4

F2855—12

Standard Specification for Chlorinated Poly(Vinyl Chloride)/Aluminum/Chlorinated Poly(Vinyl Chloride) (CPVC-AL-CPVC) Composite Pressure Tubing

Table 1202.4

F3226—16

Standard Specification for Metallic Press-connect Fittings for Piping and Tubing Systems

Table 1302.3

F3253—2017

Standard Specification for Crosslinked Polyethylene (PEX) Tubing with Oxygen Barrier for Hot- and Cold-water Hydronic Distribution Systems

Table 1202.4, Table 1202.5

AWS

American Welding Society
8669 NW 36 Street, #130
Miami, FL 33166

A5.8/A5.8—2011-AMD1

Specifications for Filler Metals for Brazing and Braze Welding

1203.3.1, 1303.3.1

AWWA

American Water Work Association
6666 West Quincy Avenue
Denver, CO 80235

C110/A21.10—12

Standard for Ductile Iron & Gray Iron Fittings

Table 1202.5

C115/A21.15—11

Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded Flanges

Table 1202.4

C151/A21.51—17

Ductile-iron Pipe, Centrifugally Cast 

Table 1202.4

C153/A21.53—11

Standard for Ductile-iron Compact Fittings for Water Service

Table 1202.5

C901—16

Polyethylene (PE) Pressure Pipe and Tubing, 3/4 in. (19 mm) through 3 in. (76 mm) for Water Service

Table 1210.4

CPSC

Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814

CPSC August 2011

Title 15 of the Federal Hazardous Substance Act

202, 1009.1

CSA

CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516

ANSI/CSA FC1—2014

Fuel Cell Technologies—Part 3-100: Stationary Fuel Cell Power Systems—Safety

924.1

ANSI/CSA/IGSHPA C448 Series—16

Design and Installation of Ground Source Heat Pump Systems for Commercial and Residential Buildings

Table 1202.4, Table 1202.5, Table 1210.5

B137.1—17

Polyethylene (PE) Pipe, Tubing and Fittings for Cold-water Pressure Services

Table 1210.4, Table 1210.5

B137.2—17

Polyvinylchloride (PVC) Injection-moulded Gasketed Fittings for Pressure Applications

Table 1210.5

B137.3—17

Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications

Table 1210.5

B137.5—17

Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications

Table 1202.5, Table 1210.4, Table 1210.5

B137.6—17

Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot- and Cold-water Distribution Systems

Table 1210.5

B137.9—17

Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-pipe Systems

Table 1202.4, Table 1210.4, Table 1210.5

B137.10—17

Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Composite Pressure-pipe Systems

Table 1202.4

B137.11—17

Polypropylene (PP-R) Pipe and Fittings for Pressure Applications

Table 1210.4, Table 1210.5

B137.18—17

Polyethylene of Raised Temperature Resistance (PE-RT) Tubing Systems for Pressure Applications

Table 1202.4, Table 1202.5, Table 1210.5

C22.2 No. 218.1—13(R2017)

Spas, Hot Tubs and Associated Equipment

916.1

C22.2 No. 236—15

Heating and Cooling Equipment

916.1

DOL

U.S. Department of Labor Occupational Safety and Health Administration
c/o Superintendent of Documents U.S. Government Printing Office
Washington, DC 20402-9325

29 CFR Part 1910.1000 (2015)

Air Contaminants

502.6

29 CFR Part 1910.1025 (2015)

Toxic and Hazardous Substances

502.19

FDA

U.S. Food and Drug Administration
10903 New Hampshire Avenue
Silver Springs, MD 20993

FDA Title 15

Federal Hazardous Substances Act

1403.4

FDA Title 21

Code of Federal Regulations, Title 21, Food and Drugs, Chapter 1, Food and Drug Administration, Parts 174—186 (revised as of April 1, 2015)

1403.3

FS

Federal Specifications* General Services Administration
7th & D Streets Specification Section, Room 6039
Washington, DC 20407

WW-P-325B (1976)

Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and Waste Applications)
*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325

Table 1202.4

ICC

International Code Council, Inc.
500 New Jersey Ave NW 6th Floor
Washington, DC 20001

ICC 901/SRCC Standard 100—20

Solar Thermal Collector Standard

1401.4.1, 1402.8.1.1

IFGC—21

International Fuel Gas Code®

101.2, 201.3, 301.6, 701.1, 801.1, 901.1, 906.1, 926.1, 1101.5

IPC—21

International Plumbing Code®

201.3, 301.11, 307.2.2, 512.2, 908.5, 928.1, 1002.1, 1002.2, 1002.3, 1005.2, 1006.6, 1008.2, 1009.3, 1101.4, 1201.1, 1206.2, 1206.3, 1210.8.1, 1401.2

IIAR

International Institute of Ammonia Refrigeration
1001 N. Fairfax Street, Suite 503
Arlington, VA 22314

ANSI/IIAR 2—2014, Including Addendum A

Safe Design of Closed-circuit Ammonia Refrigeration Systems

1101.6, 1105.6.3

ANSI/IIAR 3—2017

Ammonia Refrigeration Valves

1101.6

ANSI/IIAR 4—2020

Installation of Closed-circuit Ammonia Mechanical Refrigeration Systems

1101.6

ANSI/IIAR 5—2019

Startup of Closed-circuit Ammonia Refrigeration Systems

1101.6

MSS

Manufacturers Standardization Society of the Valve and Fittings Industry, Inc.
127 Park Street, NE
Vienna, VA 22180

SP 58—2018

Pipe Hangers and Supports—Materials Design and Manufacture, Selection, Application and Installation

305.4

NAIMA

North American Insulation Manufacturers Association
11 Canal Center Plaza, Suite 103
Alexandria, VA 22314

AH116—09

Fibrous Glass Duct Construction Standards

603.5, 603.9

NBBI

National Board of Boiler and Pressure Vessel Inspectors
1055 Crupper Avenue
Columbus, OH 43229-1183

NBIC—2017

National Board Inspection Code, Part 3

1003.3

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471

2—19

Hydrogen Technologies Code

502.16.1

30A—21

Code for Motor Fuel-dispensing Facilities and Repair Garages

304.6

31—20

Standard for the Installation of Oil-burning Equipment

701.1, 801.2.1, 801.18.1, 801.18.2, 920.2, 922.1, 1308.1

37—18

Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines

915.1, 915.2

58—20

Liquefied Petroleum Gas Code

502.9.10

69—19

Standard on Explosion Prevention Systems

510.8.3

70—20

National Electrical Code

301.7, 306.3.1, 306.4.1, 511.1.1, 513.11, 513.12.2, 602.2.1.1, 927.2, 1104.2.2, 1106.3, 1402.8.1.4

72—19

National Fire Alarm and Signaling Code

606.3

80—19

Standard for Fire Doors and Other Opening Protectives

607.4.1.2

82—19

Incinerators and Waste and Linen Handling Systems and Equipment

601.1

85—19

Boiler and Combustion Systems Hazards Code

1004.1

91—20

Exhaust Systems for Air Conveying of Vapors, Gases, Mists and Noncombustible Particulate Solids

502.9.5.1, 502.17

92—18

Standard for Smoke Control Systems

513.7, 513.8

96—20

Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations

507.1

99—21

Health Care Facilities Code

407.1

105—19

Standard for Smoke Door Assemblies and Other Opening Protectives

607.4.1.2

211—19

Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances

806.1

262—19

Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-handling Spaces

602.2.1.1

286—19

Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth

602.2.1.6

704—17

Standard System for Identification of the Hazards of Materials for Emergency Response

502.8.4, 510.1, Table 1103.1

853—20

Standard on Installation of Stationary Fuel Cell Power Systems

924.1

NSF

NSF International
789 N. Dixboro Road P.O. Box 130140
Ann Arbor, MI 48105

14—2017

Plastic Piping System Components and Related Materials

301.4

358-1—2017

Polyethylene Pipe and Fittings for Water-based Ground-source "Geothermal" Heat Pump Systems

Table 1210.4, Table 1210.5

358-2—2017

Polypropylene Pipe and Fittings for Water-based Ground-source "Geothermal" Heat Pump Systems

Table 1210.4, Table 1210.5

358-3—2016

Cross-linked Polyethylene (PEX) Pipe and Fittings for Water-based Ground-source (Geothermal) Heat Pump Systems

Table 1210.4, Table 1210.5

358-4—2017

Polyethylene of Raised Temperature (PE-RT) Pipe and Fittings for Water-based Ground-source (Geothermal) Heat Pump Systems

Table 1210.4, Table 1210.5

SMACNA

Sheet Metal and Air Conditioning Contractors' National Association, Inc.
4201 Lafayette Center Drive
Chantilly, VA 20151-1219

SMACNA—2010

Fibrous Glass Duct Construction Standards, 7th Edition

603.5, 603.9

SMACNA—2015

SMACNA Phenolic Duct Construction Standards, 1st Edition (ANSI)

603.5.2

SMACNA/ANSI—2011

Rectangular Industrial Duct Construction Standards, 2nd Edition

510.8.1

SMACNA/ANSI—2013

Round Industrial Duct Construction Standards, 3rd Edition

510.8.1

SMACNA/ANSI—2016

HVAC Duct Construction Standards—Metal and Flexible, 4th Edition (ANSI)

603.10, 603.4, Table 603.4, 603.9

UL

UL LLC
333 Pfingsten Road
Northbrook, IL 60062-2096

17—2008

Vent or Chimney Connector Dampers for Oil-fired Appliances—with revisions through September 2013

803.6

103—2010

Factory-built Chimneys, Residential Type and Building Heating Appliances—with revisions through March 2017

805.2

109—97

Tube Fittings for Flammable and Combustible Fluids, Refrigeration Service and Marine Use

Table 1101.2

127—2011

Factory-built Fireplaces—with revisions through July 2016

903.1, 903.3, 903.4

174—04

Household Electric Storage Tank Water Heaters—with revisions through December 2016

1002.1

180—2012

Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids—with revisions through May 2017

1306.4

181—05

Factory-made Air Ducts and Air Connectors—with revisions through April 2017

512.2, 603.5, 603.6.1, 603.6.2, 603.9, 604.13

181A—2013

Closure Systems for Use with Rigid Air Ducts and Air Connectors—with revisions through March 2017

603.9

181B—2013

Closure Systems for Use with Flexible Air Ducts and Air Connectors—with revisions through March 2017

603.9

197—10

Commercial Electric Cooking Appliances—with revisions through January 2018

917.1

207—2009

Refrigerant-containing Components and Accessories, Nonelectrical—with revisions through June 2014

1101.2

263—2011

Fire Test of Building Construction and Materials—with revisions through March 2018

607.5.2, 607.5.5, 607.6.1, 607.6.2.1

268—2016

Smoke Detectors for Fire Alarm Systems—with revisions through July 2016

606.1

268A—2008

Smoke Detectors for Duct Application—with revisions through August 2016

606.1

343—2017

Pumps for Oil-burning Appliances

1302.7

378—2006

Draft Equipment—with revisions through September 2013

804.3, 804.3.8

391—2010

Solid-fuel and Combination-fuel Central and Supplementary Furnaces—with revisions through June 2014

918.1

412—2011

Refrigeration Unit Coolers—with revisions through August 2018

1101.2

427—11

Standard for Refrigerating Units

Table 1101.2

471—2010

Commercial Refrigerators and Freezers—with revisions through November 2018

1101.2

474—15

Standard for Dehumidifiers

Table 1101.2

484—14

Standard for Room Air Conditioners

Table 1101.2

499—2014

Electric Heating Appliances—with revisions through February 2017

912.1, 923.1

507—2017

Electric Fans—with revisions through August 2018

505.2

508—2018

Industrial Control Equipment

307.2.3

536—2014

Flexible Metallic Hose

1302.8

555—06

Fire Dampers—with revisions through October 2016

607.3.1

555C—2014

Ceiling Dampers—with revisions through May 2017

607.3.1

555S—2014

Smoke Dampers—with revisions through October 2018

607.3.1

586—2009

High-efficiency, Particulate, Air Filter Units—with revisions through December 2017

605.2

641—2010

Type L Low-temperature Venting Systems—with revisions through April 2018

802.1

705—2017

Power Ventilators—with revisions through October 2018

504.5

710—2012

Exhaust Hoods for Commercial Cooking Equipment—with revisions through June 2018

507.1

710B—2011

Recirculating Systems—with revisions through August 2014

507.1, 507.2

723—2018

Surface Burning Characteristics of Building Materials

510.8, 602.2, 602.2.1, 602.2.1.6, 602.2.1.7, 604.3, 1204.1

726—95

Oil-fired Boiler Assemblies—with revisions through October 2013

916.1, 1004.1

727—2018

Oil-fired Central Furnace

918.1

729—2003

Oil-fired Floor Furnaces—with revisions through November 2016

910.1

730—2003

Oil-fired Wall Furnaces—with revisions through November 2016

909.1

731—2018

Oil-fired Unit Heaters

920.1

732—2018

Oil-fired Storage Tank Water Heaters

1002.1

737—2011

Fireplace Stoves

905.1

762—2013

Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances

506.5.1

791—2006

Residential Incinerators—with revisions through November 2014

907.1

834—04

Heating, Water Supply and Power Boilers Electric—with revisions through September 2018

1004.1

842—2015

Valves for Flammable Fluids—with revisions through May 2015

1307.1

858—2014

Household Electric Ranges—with revisions through June 2018

917.1

864—2014

Control Units and Accessories for Fire Alarm Systems—with revisions through October 2018

513.12

867—2011

Electrostatic Air Cleaners—with revisions through August 2018

605.2

875—2009

Electric Dry Bath Heater—with revisions through September 2017

914.2

896—1993

Oil-burning Stoves—with revisions through November 2016

917.1, 922.1

900—2015

Air Filter Units

605.2

907—2016

Fireplace Accessories

902.2

923—2013

Microwave Cooking Appliances—with revisions through July 2017

917.1

959—2010

Medium Heat Appliance Factory-built Chimneys—with revisions through June 2014

805.6

971A—2006

Outline of Investigation for Metallic Underground Fuel Pipe

1302.9

1046—2010

Grease Filters for Exhaust Ducts—with revisions through April 2017

507.2.8

1240—2005

Electric Commercial Clothes-Drying Equipment—with revisions through March 2018

913.1

1261—01

Electric Water Heaters for Pools and Tubs—with revisions through September 2017

916.1

1369—18

Standard for Aboveground Piping for Flammable and Combustible Liquids

1302.9

1370—11

Unvented Alcohol Fuel Burning Decorative Appliances—with revisions through March 25, 2016

929.1

1453—2016

Electric Booster and Commercial Storage Tank Water Heaters—with revisions through May 2018

1002.1

1479—2015

Fire Tests of Penetration Firestops

506.3.11.2, 506.3.11.3

1482—2011

Solid-fuel Type Room Heaters—with revisions through August 2015

905.1

1563—2009

Standard for Electric Spas, Hot Tubs and Associated Equipment—with revisions through October 2017

916.1

1618—2015

Wall Protectors, Floor Protectors and Hearth Extensions—with revisions through January 2018

308.4.1, 903.2, 905.3

1777—2007

Chimney Liners—with revisions through April 2014

801.16.1, 801.18.4

1812—2013

Ducted Heat Recovery Ventilators—with revisions through July 2018

514.1

1815—2012

Nonducted Heat Recovery—with revisions through July 2018

514.1

1820—2004

Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics—with revisions through July 2017

602.2.1.3

1887—04

Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics—with revisions through July 2017

602.2.1.2

1978—2010

Grease Ducts—with revisions through April 2017

506.3.2, 506.3.6

1995—2015

Heating and Cooling Equipment—with revisions through August 2018

908.1, 911.1, 918.1, 918.2, 1101.2

1996—2009

Electric Duct Heaters—with revisions through July 2016

911.1

2024—2014

Safety Optical-fiber and Communications Cable Raceway—with revisions through August 2015

602.2.1.1

2043—2013

Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-handling Spaces—with revisions through July 2018

602.2.1.4.2

2075—2013

Gas and Vapor Detectors and Sensors—with revisions through December 2017

404.1

2158—2018

Electric Clothes Dryers

913.1

2158A—2013

Outline of Investigation for Clothes Dryer Transition Duct—with revisions through April 2017

504.9.3

2162—2014

Outline of Investigation for Commercial Wood-fired Baking Ovens—Refractory Type

917.1

2200—2012

Stationary Engine Generator Assemblies—with revisions through October 2015

915.1

2221—2010

Tests of Fire Resistive Grease Duct Enclosure Assemblies

506.3.11.3

2523—2009

Solid Fuel-fired Hydronic Heating Appliances, Water Heaters, and Boilers—with revisions through March 2018

1002.1, 1004.1

2846—2014

Fire Test of Plastic Water Distribution Plumbing Pipe for Visible Flame and Smoke Characteristics—with revisions through December 2016

602.2.1.7

8782—17

Outline of Investigation for Pollution Control Units for Commercial Cooking

506.5.2

UL/CSA 60335-2-40—17

Household and Similar Electrical Appliances—Safety—Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers

908.1, 916.1, 918.1, 918.2

UL/CSA 60335-2-89—17

Household and Similar Electrical Appliances—Safety—Part 2-89: Particular Requirements for Commercial Refrigerating Appliances with an Incorporated or Remote Refrigerant Unit or Compressor

Table 1101.2