About this chapter: This code contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials and methods of construction. Chapter 6 contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R108.

AAMA

American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg, IL 60173-4268

AAMA/WDMA/CSA 101/I.S.2/A C440—17

North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights

R402.4.3

ACCA

Air Conditioning Contractors of America
1330 Braddock Place, Suite 350
Alexandria, VA 22314

ANSI/ACCA 2 Manual J—16

Residential Load Calculation 

R403.7

ANSI/ACCA 3 Manual S—14

Residential Equipment Selection

R403.7

APSP

Pool & Tub Alliance (formerly the APSP)
2111 Eisenhower Avenue, Suite 500
Alexandria, VA 22314

ANSI/APSP/ICC 14—2019

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2011

American National Standard for Residential Swimming Pool and Spas—Includes Addenda A Approved January 9, 2013

R403.12

ASHRAE

ASHRAE
180 Technology Parkway NW
Peachtree Corners, GA 30092

ASHRAE 193—2010(RA 2014)

Method of Test for Determining the Airtightness of HVAC Equipment

R403.3.4.1

ASHRAE—2001

2001 ASHRAE Handbook of Fundamentals

Table R405.4.2(1)

ASHRAE—2021

ASHRAE Handbook of Fundamentals

R402.1.5

ASTM


ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken, PA 19428-2959

C1363—11

Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus

R303.1.4.1

E283—2004(2012)

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen

R402.4.4

E779—2010(2018)

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

R402.4.1.2

E1554/E1554M—E2013

Standard Test Methods for Determining Air Leakage of Air Distribution Systems by Fan Pressurization

R403.3.5

E1827—2011(2017)

Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door

R402.4.1.2

E2178—2013

Standard Test Method for Air Permanence of Building Materials

R303.1.5

CSA


CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516

AAMA/WDMA/CSA 101/I.S.2/A440—17

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3

CSA B55.1—2015

Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units

R403.5.3

CSA B55.2—2015

Drain Water Heat Recovery Units

R403.5.3

DASMA


Door & Access Systems Manufacturers Association
1300 Sumner Avenue
Cleveland, OH 44115-2851

105—2017

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors

R303.1.3

HVI


Home Ventilating Institute
1740 Dell Range Blvd, Ste H, PMB 450
Cheyenne, WY 82009

916—18

Airflow Test Procedure

Table R403.6.2

ICC


International Code Council, Inc.












500 New Jersey Avenue NW6th Floor
Washington, DC 20001

ANSI/APSP/ICC 14—2019

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2020

American National Standard for Residential Swimming Pool and Spa Energy Efficiency

R403.12

ANSI/RESNET/ICC 301—2019

Standard for the Calculation and Labeling of the Energy Performance of Dwelling and Sleeping Units using an Energy Rating Index 

R406.4

ANSI/RESNET/ICC 380—2019

Standard for Testing Airtightness of Building, Dwelling Unit and Sleeping Unit Enclosures; Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems

R402.4.1.2

ICC 400—17

Standard on the Design and Construction of Log Structures

R402.1

ICC 500—2020

ICC/NSSA Standard for the Design and Construction of Storm Shelters

R402.5

IECC—06

2006 International Energy Conservation Code®

R202

IECC—09

2009 International Energy Conservation Code®

R406.2

IECC—15

2015 International Energy Conservation Code®

Table R406.5

IFGC—21

International Fuel Gas Code®

R201.3, R501.4

IPC—21

International Plumbing Code®

R201.3, R501.4

IPMC—21

International Property Maintenance Code®

R501.4

IPSDC—21

International Private Sewage Disposal Code®

R501.4

IEEE


Institute of Electrical and Electronics Engineers, Inc.




3 Park Avenue, 17th Floor
New York, NY 10016-5997

515.1—2012

IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications

R403.5.1.2

NEMA

National Electrical Manufacturers Association
1300 17th Street North No. 900
Arlington, VA 22209

OS 4—2016

Requirements for Air-Sealed Boxes for Electrical and Communication Applications

R402.4.6

NFPA


National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471

70—20

National Electrical Code

R501.4

NFRC


National Fenestration Rating Council, Inc.


6305 Ivy Lane, Suite 140
Greenbelt, MD 20770

100—2020

Procedure for Determining Fenestration Products U-factors

R303.1.3

200—2020

Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence

R303.1.3

400—2020

Procedure for Determining Fenestration Product Air Leakage

R402.4.3

RESNET


Residential Energy Services Network, Inc.
P.O. Box 4561
Oceanside, CA 92052-4561

ANSI/RESNET/ICC 301—2019

Standard for the Calculation and Labeling of the Energy Performance of Dwelling and Sleeping Units using an Energy Rating Index 

R406.4, R406.7.1, R406.7.6

ANSI/RESNET/ICC 380—2019

Standard for Testing Airtightness of Building, Dwelling Unit and Sleeping Unit Enclosures; Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems

R402.4.1.2, R403.3.5

UL


UL LLC











333 Pfingsten Road
Northbrook, IL 60062

127—2011

Standard for Factory-Built Fireplaces—with Revisions through July 2016

R402.4.2

515—2015

Standard for Electrical Resistance Trace Heating for Commercial Applications 

R403.5.1.2

US-FTC


United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580

CFR Title 16 (2015)

R-value Rule

R303.1.4

WDMA


Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington, DC 20036-3309

AAMA/WDMA/CSA 101/I.S.2/A440—17

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3