Heads up: There are no amended sections in this chapter.

User note:

About this chapter: This code contains numerous references to standards that are used to regulate materials and methods of construction. Chapter 16 contains a comprehensive list of all standards that are referenced in the code, including the appendices. The standards are part of the code to the extent of the reference to the standard. Compliance with the referenced standard is necessary for compliance with this code. By providing specifically adopted standards, the construction and installation requirements necessary for compliance with the code can be readily determined. The basis for code compliance is, therefore, established and available on an equal basis to the building code official, contractor, designer and owner.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.


ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
7—1988 Minimum Design Loads and Associated Criteria for Buildings and Other Structures 503.12, 706.3.2
7—1993 Minimum Design Loads and Associated Criteria for Buildings and Other Structures 503.12, 706.3.2
7—1995 Minimum Design Loads and Associated Criteria for Buildings and Other Structures 503.12, 706.3.2
7—1998 Minimum Design Loads and Associated Criteria for Buildings and Other Structures 503.12, 706.3.2
7—2002 Minimum Design Loads and Associated Criteria for Buildings and Other Structures 503.12, 706.3.2
7—2005 Minimum Design Loads and Associated Criteria for Buildings and Other Structures 503.12, 706.3.2
7—2010 Minimum Design Loads and Associated Criteria for Buildings and Other Structures 503.12, 706.3.2
7—2016 Minimum Design Loads and Associated Criteria for Buildings and Other Structures with Supplement 1 304.2, 304.3.1, 503.4, 503.12, 503.13, 706.3.2, 805.3, 805.4
41—2017 Seismic Evaluation and Retrofit of Existing Buildings 304.3.1, Table 304.3.1, 304.3.2, Table 304.3.2
   
ASHRAE ASHRAE
1791 Tullie Circle NE
Atlanta, GA 30329
62.1—2019 Ventilation for Acceptable Indoor Air Quality 807.2
   
ASME American Society of Mechanical Engineers
Two Park Avenue
New York, NY 10016
A17.1—2019/CSA B44—19 Safety Code for Elevators and Escalators 306.7.7, 902.1.2
A17.3—2020 Safety Code for Existing Elevators and Escalators 902.1.2
A18.1—2020 Safety Standard for Platform Lifts and Stairway Chair Lifts 306.7.8
   
ASTM ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken, PA 19428-2959
C94/C94M—17A Specification for Ready-mixed Concrete 109.3.1
E108—17 Standard Test Methods for Fire Tests of Roof Coverings 1204.5
E136—16A Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 202
F2006—17 Standard Safety Specification for Window Fall Prevention Devices for Non-Emergency Escape (Egress) and Rescue (Ingress) Windows 505.2, 702.4
F2090—17 Standard Specification for Window Fall Prevention Devices with Emergency (Egress) Release Mechanisms 505.2, 505.3.1, 702.4, 702.5.1
   
ICC International Code Council, Inc.
500 New Jersey Avenue NW 6th Floor
Washington, DC 20001
IBC—21 International Building Code® 101.4.1, 104.2.1, 106.2.2, 109.3.3, 109.3.6, 109.3.9, 109.3.10, 110.2, 202, 301.3, 302.4.1, 302.5, 303.1, 303.2.2, 304.1, 304.3.1, 304.3.2, 305.1, 306.5, 306.7, 306.7.2, 306.7.4, 306.7.5, 306.7.9, 306.7.10, 306.7.10.1, 306.7.10.2, 306.7.10.3, 306.7.11, 306.7.12, 306.7.13, 306.7.15, 306.7.16, 306.7.16.3, 306.7.16.4, 306.7.16.5, 306.7.16.7, 309.2, 401.3, 402.1, 405.2.1.1, 405.2.3.1, 405.2.3.3, 405.2.4, 405.2.5, 405.2.6, 501.2, 502.1, 502.3, 502.4, 502.5, 503.1, 503.2, 503.3, 503.4, 503.5, 503.11, 503.12, 503.13, 503.14, 503.15, 503.17, 503.18, 505.3, 505.4, 506.1, 506.3, 506.4, 506.5.1, 506.5.2, 506.5.3, 506.5.4, 507.3, 701.2, 701.3, 702.1, 702.2, 702.3, 702.5, 702.6, 702.7, 704.1.1, 704.3, 705.1, 705.2, 706.2, 706.3.2, 802.2.1, 802.2.3, 802.3, 802.4, 802.5.2, 802.6, 802.6, 803.1.1, 803.2, 803.2.2, 803.2.3, 803.2.4, 803.2.5, 803.3, 804.1, 804.4.1, 804.4.1.1, Table 804.4.1.1(1), 804.4.1.2.1, 804.5.1.2, 804.5.3, 804.5.4, 804.5.5, 804.6, 804.7, 804.8.1, 804.9.1, 804.10.2, 804.11, 804.12.2, 805.2, 805.3, 805.4, 904.1.2, 904.1.3, 904.1.4, 904.1.6, 904.1.7, 904.2, 904.2.1, 904.2.2, 905.2, 905.3, 905.4, 906.2, 906.3, 906.6, 1001.2, 1001.3, 1002.1, 1002.2, 1002.3, 1002.4, 1004.1, 1006.1, 1006.2, 1006.3, 1006.4, 1010.1, 1011.1, 1011.2.1, 1011.2.2, 1011.3, 1011.5.1, 1011.5.2, 1011.5.3, 1011.5.6, 1011.6.1, 1011.6.1.1, 1011.6.3, 1011.7.1, 1011.7.2, 1011.7.3, 1011.8.1, 1011.8.2, 1011.8.3, 1102.1, 1102.2, 1102.3, 1103.1, 1103.2, 1103.3, 1201.4, 1202.2, 1203.12, 1204.2, 1204.9, 1206.1, 1301.2.2, 1301.2.3, 1301.2.4, 1301.3.3, 1301.4.1, 1301.6.1, 1301.6.1.1, 1301.6.2, 1301.6.2.1, 1301.6.3.2, 1301.6.3.3, 1301.6.4.1, 1301.6.5, 1301.6.5.1, 1301.6.6, 1301.6.7.1, 1301.6.8, 1301.6.9, 1301.6.9.1, 1301.6.10, 1301.6.10.1, 1301.6.11, 1301.6.11.1, 1301.6.12.1, 1301.6.13, Table 1301.6.15, 1301.6.15.1, 1301.6.16.1, 1301.6.17, 1301.6.17.1, 1301.6.18, 1301.6.18.1, 1301.6.19, Table 1301.6.19, 1301.6.20, 1301.6.20.1, 1301.9.1, 1401.2, 1402.1, 1402.2, 1402.2.1, 1402.3, 1402.4, 1402.5, 1402.6, 1501.5, 1501.6.1, 1501.6.4.1, 1501.6.7, 1506.1, 1506.3, 1507.1
ICC 300—17 ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands 301.1.1
ICC 500—20 Standard for the Design and Construction of Storm Shelters 303.1, 303.2
ICC A117.1—17 Accessible and Usable Buildings and Facilities 306.3, 306.7, 306.7.11, 306.7.12
IECC—21 International Energy Conservation Code® 302.2, 702.7, 708.1, 809.1, 907.1, 1104.1
IFC—21 International Fire Code® 101.2.1, 101.4.2, 301.3.1, 302.2, 307.1, 308.1, 802.2.1, 802.2.3, 803.2.3, 803.4.1.1, 803.4.1.2, 803.4.1.3, 803.4.1.4, 803.4.1.5, 803.4.1.6, 904.1.5, 1011.6.1.1, 1301.3.2, 1301.6.8.1, 1301.6.14, 1301.6.14.1, 1401.2, 1501.5, 1504.1, 1504.2
IFGC—21 International Fuel Gas Code® 302.2, 702.7.1
IMC—21 International Mechanical Code® 302.2, 702.7, 807.1, 902.1.1, 1008.1, 1301.6.7.1, 1301.6.8, 1301.6.8.1
IPC—21 International Plumbing Code® 302.2, 408.1, 702.7, 1009.1, 1009.2, 1009.3, 1009.5, 1501.7
IPMC—21 International Property Maintenance Code® 101.4.2, 302.2, 1301.3.2, 1401.2
IRC—21 International Residential Code® 101.2, 101.4.1, 104.2.1, 109.3.3, 109.3.10, 302.2, 307.1, 308.1, 401.3, 402.1, 405.2.6, 502.3, 502.4, 502.5, 503.2, 503.3, 503.11, 505.2, 505.3, 507.3, 701.3, 702.4, 702.5, 706.2, 708.1, 805.2, 806.4, 809.1, 906.2, 907.1, 1011.2.1, 1103.1, 1103.2, 1103.3, 1104.1, 1201.4, 1301.2.2, 1301.2.3, 1301.3.3, 1401.2, 1402.1, 1402.2, 1402.2.1, 1402.3, 1402.4, 1402.5, 1402.6
   
NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
NFPA 13R—19 Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height 803.2.4
NFPA 70—20 National Electrical Code 107.3, 302.2, 406.1.1, 406.1.2, 406.1.3, 406.1.5, 806.1, 806.4.4, 1007.1, 1007.2, 1007.3, 1007.4
NFPA 72—19 National Fire Alarm and Signaling Code 803.2.6, 803.4
NFPA 99—21 Health Care Facilities Code 302.2.1, 406.1.4, 408.3, 501.3, 707.1, 806.3, 808.1, 1007.1
NFPA 101—21 Life Safety Code 804.2
   
UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062
790—04 Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through October 2018 1204.5