Heads up: There are no amended sections in this chapter.

This Part covers the codes, standards, and specifications incorporated in this Code by reference and the specific editions that are applicable (see 9.1). This Part also lists the names and addresses of the organizations from which these documents may be procured (see 9.2).

Only that portion of the code, standard, or specification as specified by the requirements in this Code is applicable.

Designation Standard Publisher Applicable to
16 CFR Part 1201-03 Architectural Glazing Standards and Related Materials U.S. GPO U.S.
30 CFR 75.1106 Code Federal Regulations U.S. GPO U.S.
ADA/ABAAG 2010 ADA Standards for Accessible Design/Architectural Barriers Act Accessibility Guidelines U.S. ATBCB U.S.
ADAAG Americans With Disability Act Accessibility Guidelines U.S. ATBCB U.S.
AGMA 218.01 Rating the Pitting Resistance and Bending Strength of Spur and Helical Involute Gear Teeth AGMA U.S.
AISC Book No. S326, 1978 Specification for Design, Fabrication, and Erection of Structural Steel for Buildings AISC U.S.
American Plywood Design
Specification A3.3.1 (April 1978)
... APA U.S., Canada
ANSI A10.4 (latest edition) Safety Requirements for Personnel Hoists ANSI U.S.
ANSI A10.5 (latest edition) Safety Requirements for Material Hoists ANSI U.S.
ANSI A12.1-1973 Safety Requirements for Floor and Wall Openings, Railings and Toe Boards ANSI U.S.
ANSI A14.3-2002 Safety Requirements for Fixed Ladders ANSI U.S., Canada
ANSI A58.1 (latest edition) Building Code Requirements for Minimum Design Loads in Buildings and Other Structures ANSI U.S.
ANSI Z35.1-1972 Specifications for Accident Prevention Signs ANSI U.S.
ANSI Z97.1-1994 Performance Specifications and Methods of Test for Safety Glazing Material Used in Buildings ANSI U.S.
ANSI Z535.2 (latest edition) Environment & Facility Safety Signs ANSI U.S., Canada
ANSI Z535.4 (latest edition) Product Safety Signs and Labels ANSI U.S., Canada
ANSI/ACI 318-08 Building Code Requirements for Reinforced Concrete ACI U.S.
ANSI/AISC 360-05 Specification for Structural Steel Buildings AISC U.S.
ANSI/AF&PA NDS-2005 National Design Specifications for Wood Construction ANSI U.S.
ANSI/AWS D1.1 (latest edition) Structural Welding Code-Steel AWS U.S., Canada
ANSI/AWS D1.3 (latest edition) Structural Welding Code-Sheet Steel AWS U.S., Canada
ANSI/BHMA A156.19-2007 Power Assist and Low Energy Power Operated Doors BHMA Canada
ANSI/ISO/IEC 17024 Conformity assessment — General requirements for bodies operating certification of persons ANSI U.S., Canada
ANSI/RMA IP-20-1977 Specifications for Drives Using Classical Multiple V-belts (A, B, C, D, E Cross Sections) RMA U.S.
ANSI/SAE SP-68 . . . SAE U.S.
ANSI/SAIA A92 (latest edition) Aerial Platforms SAIA U.S.
ANSI/UL 94 (latest edition) Test of Flammability of Plastic Materials for Parts in Devices and Appliances UL U.S., Canada
ANSI/UL 723 (latest edition) Surface Burning Characteristics of Building Materials, Test for UL U.S., Canada
ANSI/Vol. Prod. Std. PS-1-74 Construction and Industrial Plywood APA U.S.
ASME A17.2 (latest edition) Guide for Inspection of Elevators, Escalators, and Moving Walks ASME U.S.
ASME A17.3 (latest edition) Safety Code for Existing Elevators and Escalators ASME U.S.
ASME A17.4 (latest edition) Guide for Emergency Personnel ASME U.S.
ASME A17.6 Standard for Elevator Suspension, Compensation, and Governor Systems ASME U.S., Canada
ASME A17.7/CSA B44.7 (latest edition) Performance-Based Safety Code for Elevators and Escalators ASME, CSA U.S., Canada
ASME A17.8/CSA B44.8 Safety Code for Wind Turbine Tower Elevators ASME, CSA U.S.
ASME A18.1 (latest edition) Safety Standard for Platform Lifts and Stairway Chairlifts ASME U.S.
ASME A90.1 (latest edition) Safety Standards for Manlifts ASME U.S.
ASME A120.1 (latest edition) Safety Requirements for Powered Platforms for Building Maintenance ASME U.S.
ASME B1.1 (latest edition) Unified Inch Screw Threads ASME U.S., Canada
ASME B1.13M (latest edition) Metric Screw Threads ASME U.S., Canada
ASME B1.20.1 (latest edition) Pipe Threads, General Purpose (Inch) ASME U.S., Canada
ASME B1.20.3 (latest edition) Dryseal Pipe Threads (Inch) ASME U.S., Canada
ASME B1.20.4-1976 (R1982) Dryseal Pipe Threads (Metric Translation of B1.20.3) ASME U.S., Canada
ASME B20.1 (latest edition) Safety Standards for Conveyors and Related Equipment ASME U.S.
ASME B29.1 (latest edition) Precision Power Transmission Roller Chains, Attachments, and Sprockets ASME U.S., Canada
ASME B29.8 (latest edition) Leaf Chains, Clevises, and Sheaves ASME U.S., Canada
ASME B29.100 (latest edition) Precision Power Transmission, Double-Pitch Power Transmission, and Double-Pitch Conveyor Roller Chains, Attachments, and Sprockets ASME U.S., Canada
ASME B31.1 (latest edition) Power Piping ASME U.S., Canada
ASME QEI-1 (latest edition) Standard for the Qualification of Elevator Inspectors ASME U.S.
ASME Y14.38 (latest edition) Abbreviations and Acronyms ASME U.S.
ASME Boiler and Pressure Vessel Code Section VIII (latest edition) . . . ASME U.S., Canada
ASME Guide SI-1 (latest edition) Orientation and Guide for Use of SI (Metric) Units ASME U.S.
ASTM A27-84a Specifications for Mild and Medium-Strength Carbon Steel Castings for General Applications ASTM U.S., Canada
ASTM A36-84a Specifications for Structural Steel ASTM U.S., Canada
ASTM A53/A53M (latest edition) Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc Coated, Welded and Seamless ASTM U.S., Canada
ASTM A106/A106M (latest edition) Standard Specification for Seamless Carbon Rule 303.1a Steel Pipe for High-Temperature Service ASTM U.S., Canada
ASTM A283-84a Specifications for Low and Intermediate Tensile Strength Threaded Standard Fasteners ASTM U.S., Canada
ASTM A283/A283M-03 (2007) Standard Specification for Low and Intermediate Tensile Strength Carbon Steel Plates BHMA Canada
ASTM A307-10 Standard Specification for Carbon Steel Bolts and Studs, 60 000 PSI Tensile Strength ASTM U.S., Canada
ASTM A307-84a Specifications for Low and Intermediate Tensile Strength Carbon Steel Plate of Structural Quality ASTM U.S., Canada
ASTM A502-83a Specifications for Steel Structural Rivets ASTM U.S., Canada
ASTM A668-85 Specifications for Carbon Allow Steel Forgings for General Industrial Use ASTM U.S., Canada
ASTM D97-85 Standard Test for Pour Point of Petroleum Oils ASTM U.S., Canada
ASTM D198-84 Static Tests of Timbers in Structural Sizes ASTM U.S., Canada
ASTM D245-81 (1986) Establishing Structural Grades and Related Allowable Properties for Visually Graded Lumber ASTM U.S., Canada
ASTM D2270-79 Calculating Viscosity Index from Kinematic Viscosity ASTM U.S., Canada
ASTM E8/E8M (latest edition) Standard Test Methods for Tension Testing of Metallic Materials ASTM U.S., Canada
ASTM E84 (latest edition) Standard Test Method for Surface Burning Characteristics of Building Materials ASTM U.S., Canada
ASTM E380 (latest edition) Standard Practice for Use of the International System of Units (SI) ASTM U.S.
ASTM E648-86 Standard Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source ASTM U.S.
CABO One and Two Family Dwelling Code . . . ICC U.S.
CAN4-S104 (latest edition) Fire Tests of Door Assemblies CSA Canada
CAN/CGSB-12.1-M90 (same as CAN2-12.1) Glass, Safety, Tempered or Laminated CGSB Canada
CAN/CGSB-12.11 (latest edition) Wired Safety Glass CGSB Canada
CAN/CGSB-12.12 (latest edition) Plastic Safety Glazing Sheets CGSB Canada
CAN/CSA B311 (latest edition) Safety Code for Manlifts CSA Canada
CAN/CSA B354.1 (latest edition) Portable Elevating Work Platforms CSA Canada
CAN/CSA-B72-M87 (R1998) (same as CSA-B72) Installation Code for Lighting Protection Systems CSA Canada
CAN/CSA G40.21-1972 Structural Quality Steels CSA Canada
CAN/CSA-S16.1-94 Limit States Design of Steel Structures CSA Canada
CAN/CSA-T515-97 (same as CAN3-T515-M85) Requirements for Handset Telephones Intended for Use by the Hard of Hearing CSA Canada
CAN/CSA-Z185-M87 (R1997) (same as CSA-Z185) Safety Code for Personnel Hoists CSA Canada
CAN/CSA-Z256-M87 (R1995) (same as CSA-Z256) Safety Code for Material Hoists CSA Canada
CAN/CSA-Z271-98 (same as CSA-Z271) Safety Code for Suspended Elevating Platforms CSA Canada
CAN/CSA-Z321 (latest edition) Signs and Symbols for the Workplace CSA U.S., Canada
CAN/ULC-S102.2 (latest edition) Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Covering, and Miscellaneous Materials and Assemblies ULC Canada
CEI IEC 61508 Parts 1 through 7 (first edition — 1998) Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems ANSI U.S., Canada
CSA A23.3-M84 (same as CAN3-A23.3) Design of Concrete Structures for Buildings CSA Canada
CSA-B44.1/ASME A17.5 (latest edition) Standard for Elevator and Escalator Electrical Equipment ASME U.S., Canada
CSA B167-96 Safety Standard for Maintenance and Inspection of Overhead Cranes, Gantry Cranes, Monorails, Hoists, and Trolleys CSA Canada
CSA B354 (latest edition) Work Platform Standards CSA Canada
CSA B355-00 Lifts for Persons With Physical Disabilities CSA Canada
CSA B613-00 Private Residence Lifts for Persons With Physical Disabilities CSA Canada
CSA C22.1 (latest edition) Canadian Electrical Code, Part I, Safety Std. for Electrical Installations CSA Canada
CSA C22.2 No. 139-1982 (R1992) Electrically Operated Valves CSA U.S., Canada
CSA C22.2 No. 141-M1985 (R1992) Unit Equipment for Emergency Lighting CSA U.S., Canada
CSA 086-01 Engineering Design in Wood CSA U.S., Canada
CSA 086.1-94 Engineering Design in Wood (Limit States Design) CSA Canada
CSA 0151-M1978 (same as CAN/CSA-0151-M78) Canadian Softwood Plywood CSA Canada
CSA W47.1-1992 (R1998) Certification of Companies for Fusion Welding of Steel Structures CSA Canada
CSA W59-M1989 Welded Steel Construction (Metal Arc Welding) (Metric Version) CSA U.S., Canada
CSA Z150-98 Safety Code on Mobile Cranes CSA Canada
CSA Z248-1975 Code for Tower Cranes CSA Canada
EN 12016: 1998 Electromagnetic Compatibility-Product Family Standard for Lifts, Escalator and Passenger Conveyors Immunity BSI U.S., Canada
FED-STD 191A Rev.5 (Dec-28-1989) Federal Standard for Textile Test Methods GSA U.S.
FED-STD-595C Colors Used in Government Procurement GSA U.S., Canada
IBC (latest edition) International Building Code ICC U.S.
ICC/ANSI A117.1 (latest edition) Accessible and Usable Buildings and Facilities ICC U.S.
IEEE 45 (latest edition) Recommended Practices for Electric Installations on Shipboard IEEE U.S., Canada
ISO 14798:2009 Lifts (elevators), escalators and moving walks — Risk assessment and reduction methodology ANSI U.S., Canada
ISO 22200:2009 Electromagnetic Compatibility — Product Family Standard for Lifts, Escalators and Moving Walks — Immunity ANSI U.S., Canada
MIL-DTL-83420M Spec . . . . . . . . .
Mineral Resources 30 CFR Parts 1-199 Code of Federal Regulations MSHA U.S. GPO U.S.
NBCC (latest edition, except where specified in the Code) National Building Code of Canada NRC Canada
NEHRP National Earthquake Hazards Reduction Program Recommended Provisions for Seismic Regulations for New Buildings FEMA U.S., Canada
NEMA 250 (latest edition) Enclosures for Electrical Equipment (1000 Volts Maximum) NEMA U.S.
NFCC (latest edition) National Fire Code of Canada NRC Canada
NFPA 13 (latest edition) Installation of Sprinkler Systems NFPA U.S.
NFPA 70 (latest edition) National Electrical Code NFPA U.S.
NFPA 72 (latest edition) National Fire Alarm Code NFPA U.S.
NFPA 80-1986 Fire Doors and Windows NFPA U.S., Canada
NFPA 99 (latest edition) Standard for Health Care Facilities NFPA U.S.
NFPA 101 (latest edition) Life Safety Code NFPA U.S.
NFPA 105 (latest edition) Recommended Practice for the Installation of Smoke Control Door Assemblies NFPA U.S., Canada
NFPA 252 (latest edition) Fire Tests of Door Assemblies NFPA U.S.
NFPA 255 (latest edition) Fire Test for Evaluating Room Fire Growth Contribution of Textile Wall Covering NFPA U.S., Canada
NFPA 265 Fire Test for Evaluating Room Fire Growth Contributions of Textile Wall Coverings NFPA U.S., Canada
NFPA 780 (latest edition) Lightning Protection Code NFPA U.S.
NFPA 1971-2000 Standard on Protective Ensemble for Structural Fire Fighting NFPA U.S.
NFPA 5000 (latest edition) Building Construction and Safety Code NFPA U.S.
SAE J514-1992 Hydraulic Tube Fittings SAE U.S., Canada
SAE J517-1991 Hydraulic Hoses SAE U.S., Canada
SEI/ASCE 24 Flood Resistance Design and Construction ASCE U.S.
SOLAS International Convention for Safety of Life at Sea, Regulation 3, 1974 Amendment . . . U.S.
UBC-1994 Uniform Building Code ICC U.S.
UL 10B (latest edition) Fire Test of Door Assemblies UL U.S.
UL 104 (latest edition) Standard for Elevator Door Locking Devices and Contacts UL U.S.
UL 924-06 (R15) Standard for Safety Emergency Lighting and Power Equipment UL U.S., Canada
UL 1037 (latest edition) Standard for Antitheft Alarms and Devices UL U.S.
UL 1784 (latest edition) Standard for Safety, Air Leakage Tests of Door Assemblies and Other Opening Protectives UL U.S.
. . . Elevator Industry Field Employees' Safety Handbook Elevator World U.S., Canada
Organization Address and Phone Number
ACI American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Telephone: [248) 848-3700
www.concrete.org
AGMA American Gear Manufacturers Association
1001 North Fairfax Street, Suite 500
Alexandria, VA 22314-1587
Telephone: (703) 684-0211
www.agma.org
AISC American Institute of Steel Construction
130 East Randolph Street
Suite 2000
Chicago, IL 60601
Telephone: (312) 670-2400
www.aisc.org
ANSI American National Standards Institute
25 West 43rd Street
New York, NY 10036
Telephone: (212) 642-4900
www.ansi.org
APA APA — The Engineered Wood Association
7011 South 19th Street
Tacoma, WA 98466-5333
Telephone: (253) 565-6600
www.apawood.org
ASCE American Society of Civil Engineers
1801 Alexander Bell Drive
Reston, VA 20191-4400
Telephone: (800) 548-2723
www.asce.org
ASME The American Society of Mechanical Engineers
Two Park Avenue
New York, NY 10016-5990
Telephone: (800) 843-2763
www.asme.org
ASTM International American Society for Testing and Materials
100 Barr Harbor Drive
P.O. Box C700
West Conshohocken, PA 19428-2959
Telephone: (610) 832-9585
www.astm.org
AWS American Welding Society
8669 NW 36th Street, No. 130
Miami, FL 33166
Telephone: (800) 443-9353
www.aws.org
BHMA Builders Hardware Manufacturers Association
355 Lexington Avenue, 15th Floor
New York, NY 10017
Telephone: (212) 297-2122
www.buildershardware.com
BSI British Standards Institution, Inc.
12950 Worldgate Drive, Suite 800
Herndon, VA 20170
Telephone: (800) 862-4977
www.bsigroup.com
CGSB Canadian General Standards Board
11 Laurier Street
Gatineau, Canada K1A 1G6
Telephone: (819) 956-0425
www.tpsgc-pwgsc.gc.ca
CSA Canadian Standards Association
178 Rexdale Boulevard
Toronto, Ontario M9W 1R3, Canada
Telephone: (800) 463-6727
www.csagroup.org
Elevator World Elevator World, Inc.
354 Morgan Avenue
Mobile, AL 36606
Telephone: (251) 479-4514
www.elevatorworld.com
FEMA Federal Emergency Management Agency
FEMA Distribution Center
P.O. Box 2012
8231 Stayton Drive
Jessup, MD 20794
Telephone: (800) 480-2520
www.fema.gov
GSA General Services Administration
Federal Acquisition Service
1800 F Street, NW
Washington, DC 20405
Telephone: (703) 605-2567
www.gsa.gov
ICC International Code Council
500 New Jersey Avenue, NW
Washington, DC 20001
Telephone: (800) 422-7233
www.iccsafe.org
IEEE Institute of Electrical and Electronics Engineers, Inc.
445 Hoes Lane
Piscataway, NJ 08854-1331
Telephone: (800) 678-4333
www.ieee.org
NEMA National Electrical Manufacturers Association
1300 North 17th Street, Suite 900
Rosslyn, VA 22209
Telephone: (703) 841-3200
www.nema.org
NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Telephone: (617) 770-3000
www.nfpa.org
NRC National Research Council of Canada
1200 Montreal Road
Building M-58
Ottawa, Ontario, K1A 0R6 Canada
Telephone: (613) 993-9101
www.nrc-cnrc.gc.ca
RMA Rubber Manufacturers Association
1400 K Street, NW
Washington, DC 20005
Telephone: [202] 682-4800
www.rma.org
SAE SAE International
400 Commonwealth Drive
Warrendale, PA 15096-0001
Telephone: [724] 776-4841
www.sae.org
SAIA Scaffold and Access Industry Association
400 Admiral Boulevard
Kansas City, MO 64106
Telephone: [816] 595-4860
www.saiaonline.org
UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
Order Address: Comm 2000
151 Eastern Avenue
Bensenville, IL 60106
Telephone: [847] 272-8800
www.ul.com
ULC Underwriters Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada MIR 3A9
Telephone: [416] 757-5250
canada.ul.com
U.S. ATBCB United States Access Board
1331 F Street, NW, Suite 1000
Washington, DC 20004-1111
Telephone: [800] 872-2253
www.access-board.gov
U.S. GPO U.S. Government Publishing Office
Superintendent of Documents
732 N. Capitol Street, NW
Washington, DC 20401
Telephone: [866] 512-1800
www.gpo.gov